1. DCS Systems Engineer International Integrated Oil Company 34 ST 03 63 Page 2 Description The ST 3000 transmitter can replace any 4 to 20 mA output transmitter in use today and operates over a standard two wire system The measuring means is a piezoresistive sensor which actually contains three sensors in one It contains a differential pressure sensor a temperature sensor and a static pressure sensor Microprocessor based electronics provide higher span turndown ratio improved temperature and pressure compensation and improved accuracy The transmitter s meter body and electronics housing resist shock vibration corrosion and moisture The electronics housing contains a compartment for the single board electronics which is isolated from an integral junction box The single board electronics is replaceable and interchangeable with any other ST 3000 Series 100 or Series 900 model transmitter Like other Honeywell transmitters the ST 3000 features two way communication and configuration capability between the operator and the transmitter through several Honeywell field rated portable configuration devices including the Smart Field Communicator SFC and the Multiple Communication Configurator MC ToolKit While both are made for in field use the MC Toolkit also can be ordered for use in intrinsically safe environments The SCT 3000 Smartline Configuration Toolkit provides an easy way to configure instruments usi
2. 3004 Im mo io Figure 4 Approximate mounting dimensions for flush diaphragm type models STF128 and STF132 34 ST 03 63 Page 15 millimeters Reference Dimensions inches millimeters inches WITH SMART METER 82 9 94 9 WITH ANALOG METER 3 26 3 74 Reference Dimensions 65 1 WITHOUT METER 2 56 CAP REMOVAL CLEARANCE i 550 EXTERNAL GROUND OPTIONAL ADAPTER B DIA FOR 1 2 NPT OF BOLT fege EXTENSIONS E FLANGE DIA HOLE DIA NO OF ce B DIA 92 1 i 3 63 92 1 EA 3 63 102 0 Pet 4 02 127 0 ii 500 127 0 R83 500 Eg 0 Eg 43 157 2 ae ae 619 157 2 eT 619 4 3004 DN100 N40 162 0 5 38 Figure 5 Approximate mounting dimensions for extended diaphragm type models STF128 and STF132 34 ST 03 63 Page 16 millimeters Reference Dimensions inches millimeters inches 118 2 4 65 Reference Dimensions 82 9 WITH SMART METER 94 9 WITH ANALOG METER 3 26 3 74 53 1 WITHOUT METER 65 1 WITHOUT METER 2 09 2 56 3 6 CUSTOMER SUPPLIED 0 14 FLANGE AND HARDWARE F CAP REMOVAL 0 mes ci OPTIONAL 1 80 EXTERNAL GROUND 174 NPT OPTIONAL ADAPTER FOR 142 NPT neh BOLT WOLES STUDS HOLES STUDS BOLT i E Ean ae ime ce CIRCLE 3 150 Figure 6 Approximate mounting dimensions for pseudo flange type models STF12F STF13F and STF14F Options Indicating Meter NAMUR NE43 Compliance Options ME an
3. 385 26 5 316 S S 534 36 8 1 434 29 9 399 27 5 STF12F STF13F STF14F ANSI Class 150 psi bar 316L Stainless 230 15 9 185 12 8 No rating at this temp Steel 1 Ambient Temperature for DN PN40 is 10 to 50 C 14 to 122 F 34 ST 03 63 Page 4 Loop 800 Resistance ohms Note A minimum of 250 ohms of loop resistance is necessary to support communications Loop resistance equals barrier resistance plus wire resistance plus receiver resistance Operating Area 450 250 0 10 8 16 28 20 63 25 28 3 37 0 42 4 Operating Voltage Vdc Figure 2 Supply voltage and loop resistance chart 34 ST 03 63 Page 5 Performance Under Rated Conditions Model STF128 0 to 400 inH2O Upper Range Limit inH2O 400 39 2 F 4 C is standard reference temperature for inH2O range mbar 1000 Minimum Span inH2O 10 mbar 25 Turndown Ratio 40 to 1 Zero Elevation and Suppression No limit except minimum span within 100 URL Specifications valid from 100 to 100 URL Accuracy Reference Includes In Analog Mode 0 10 of calibrated span or upper range value URV whichever is combined effects of linearity greater terminal based hysteresis and repeatability For URV calibrated below reference point 25 inH2O accuracy equals e Accuracy includes residual error 25 inH20 after averaging successive 0 05 0 05 or 0 05 0 05 62 5 mbar readings Span psi sp
4. 3D NACE A286 SS Bolts 316 SS Bolts B7M Bolts 316 SS Adapter Flange 1 2 NPT with CS Bolts 316 SS Adapter Flange 1 2 NPT with 316 SS Bolts 316 SS Adapter Flange 1 2 NPT with NACE A286 SS Bolts 316 SS Adapter Flange 1 2 NPT with B7M Bolts Hastelloy C Adapter Flange 1 2 NPT with CS Bolts Hastelloy C Adapter Flange 1 2 NPT with 316 SS Bolts Monel Adapter Flange 1 2 NPT with CS Bolts Monel Adapter Flange 1 2 NPT with 316 SS Bolts 316 SS Blind Adapter Flange with CS Bolts 316 SS Blind Adapter Flange with 316 SS Bolts 316 SS Blind Adapter Flange with NACE A286 SS Bolts 316 SS Blind Adapter Flange with B7M Bolts 316 SS Center Vent Drain and Bushing Viton Process Head Gaskets adapter gaskets ordered separately sn Adapter Flange Gaskets A Manual Paper Copy Standard HC H6 or FF ships accordingly Clean Transmitter for Oxygen or Chlorine Service with Certificate Over Pressure Leak Test with F3392 Certificate Calibration Test Report and Certificate of Conformance F3399 Certificate of Conformance F3391 Certificate of Origin F0195 FMEDA Certificate SIL 1 FC33321 SIL Certificate SIL 2 3 FC33337 NACE Certificate Process Wetted amp Non Process Wetted FC33339 NACE Certificate Process Wetted Only FC333xx Marine Type Approvals DNV ABS BV KR amp LR FC33340 Warranty Options o Additional Warranty 1 year Additional Warranty 2 years Additional Warranty 3 years Additional Warr
5. Mode 0 10 of span Temperature Effect per 28 C For URV below reference point 50 inH20 effect equals 50 F 50 inH20 125 mbar 0 05 0 05 span mbar en LD or 0 05 0 05 In Digital Mode 0 075 of span For URV below reference point 50 inH20 effect equals in of span 125 mbar 50 inH20 0 025 0 05 or 0 025 0 05 span mbar Span inH gt O in of span Zero Static Pressure Effect per 0 075 of span 1000 psi 70 bar For URV below reference point 50 inH20 effect equals 50 inH O 0 0125 0 0625 or 0 0125 0 0625 125 mbar span inH20 span mbar in of span Combined Zero and Span Static 0 20 of span Pressure Effect per 1000 psi 70 For URV below reference point 50 inH20 effect equals bar 50 inH20 0 1375 0 0625 span inH gt O or 0 1375 0 0625 125 mbar Senber in of span Stability 0 04 URL per year Performance specifications are based on reference conditions of 25 C 77 F zero 0 static pressure 10 to 55 RH and 316 Stainless Steel barrier diaphragm 34 ST 03 63 Page 11 Performance Under Rated Conditions General for all Models Output two wire Analog 4 to 20 mA or digital communications DE mode Options available for FOUNDATION Fieldbus and HART protocol Supply Voltage Effect 0 005 of span per volt Damping Time Constant Adjustable from 0 to 32 seconds digital damping CE Conformity Europe 89 336 EEC Electromagnet
6. elejo RESTRICTIONS Restriction Available Only With Not Available With Letter Table Selection f Table Selection a mM 3D or 3H a ae b _ Select only one option from this group e S I Si f Pa CC E E Pp SOS Pom CY COC ca a ene A gt Po im cron O O CSCO pp __ HO orHeangwe_ sm Fro zd aise E E o A A E E Pr OSS S eS rf sect sassassraravane TP a S A E po a a a n S o ee a 2 a Note See ST 83 for Published Specials with pricing See ST 89 and User s Manual for part numbers See ST OE 9 for OMS Order Entry Information including TC manuals certificates drawings and SPINS See ST OD 1 for tagging ID Transmitter Configuration TC and calibration including factory default values To request a quotation for a non published special fax RFQ to Marketing Applications 34 ST 03 63 Page 21 34 ST 03 63 Page 22 ST 3000 is a registered trademark of Honeywell International Inc HART is a trademark of the Hart Communication Foundation FOUNDATION is a trademark of the Fieldbus Foundation Honeywell Process Solutions Industrial Measurement and Control Honeywell International Inc 2500 W Union Hill Drive Phoenix Arizona 85027 Honeywell Honeywell International Inc
7. failure information is generated when the measuring information is no longer valid Transmitter failure values are lt 3 6 mA and 2 21 0 mA The normal ST 3000 ranges are lt 3 8 mA and 2 20 5 mA Tagging Option TG Up to 30 characters can be added on the stainless steel nameplate mounted on the transmitter s electronics housing at no extra cost Note that a separate nameplate on the meter body contains the serial number and body related data A stainless steel wired on tag with additional data of up to 4 lines of 28 characters is also available The number of characters for tagging includes spaces Lifetime Warranty Option WL Extends limited 1 year warranty policy to 15 years for ST 3000 S100 pressure transmitters See Honeywell Terms and Conditions Indicator Configuration Option Cl Provides custom configuration of Smart Meters Transmitter Configuration Option TC The factory can configure the transmitter linear square root extraction damping time LRV URV and mode analog digital and enter an ID tag of up to eight char acters and scratchpad information as specified Custom Calibration and ID in Memory Option CC The factory can calibrate any range within the scope of the transmitter s range and enter an ID tag of up to eight characters in the transmitter s memory 34 ST 03 63 Page 17 Ordering Information Contact your nearest Honeywell sales office or In the U S Honeywell
8. 00 39 2 F 4 C is standard reference temperature for inH2O range mbar 1500 Minimum Span inH20 25 mbar 62 2 Turndown Ratio 24 to 1 Zero Elevation and Suppression No limit except minimum span within O to 100 URL Accuracy Reference Includes In Analog Mode 0 075 of calibrated span or upper range value URV whichever is combined effects of linearity greater terminal based hysteresis and repeatability For URV below reference point 25 inH20 accuracy equals e Accuracy includes residual error 25 inH20 62 mbar after averaging successive 0 0375 0 0375 or 0 0375 0 0375 aame aT a in of span readings Spann ae 5 A For FOUNDATION Fieldbus use In Digital Mode 0 05 of calibrated span or upper range value URV whichever is a FOD greater terminal based Digital Mode specifications For 3 HART use Analog Mode For URV below reference point 25 inH20 accuracy equals specifications 25 inH2O 62 mbar 0 0125 0 0375 or 0 0125 0 0375 ranma T span inH gt O in of span Zero Temperature Effect per In Analog Mode 0 0625 of span 28 C 50 F For URV below reference point 50 inH20 effect equals 50 inH20 125 mbar 0 0125 0 05 E or 0 0125 0 05 aren mbar in of span In Digital Mode 0 05 of span For URV below reference point 50 inH20 effect equals 50 inH20 125 mbar 0 05 Sanit or 0 05 aama in of span Combined Zero and Span In Analog
9. 2 40 to 110 40 to 230 40 to 125 40 to 257 55 to 125 67 to 257 7742 7742 STF14F 40 to 85 40 to 185 40to85 40to 185 55 to 125 67 to 257 Process Interface Temp STF128 STF132 only 25 1 40 to 110 40 to 230 40 to 175 40 to 350 55 to 125 67 to 257 Humidity RH 10 to 55 0 to 100 0 to 100 0 to 100 Minimum Pressure mmHg absolute atmospheric 25 2 short term inH20 absolute atmospheric 13 1 short term Supply Voltage Current and Voltage Range 10 8 to 42 4 Vdc at terminals Load Resistance Current Range 3 0 to 21 8 mA Load Resistance 0 to 1440 ohms as shown in Figure 2 For CTFE fill fluid the rating is 15 to 110 C 5 to 230 F For CTFE fill fluid the maximum temperature rating is 150 C 300 F Short term equals 2 hours at 70 C 158 F Maximum Allowable Working Pressure MAWP STF 128 STF 132 Flange Ambient Maximum Meterbody Process Interface Material Temperature Temperature Temperature 29 to 38 C 125 C 257 F 175 C 350 F 20 to 100 F ANSI Class 150 Carbon Steel 285 19 6 245 16 9 215 14 8 psi bar 304 S S 275 19 0 218 15 0 198 13 7 316 S S 275 19 0 225 15 5 205 14 1 ANSI Class 300 Carbon Steel 740 51 0 668 46 0 645 44 5 psi bar 304 S S 720 49 6 570 39 3 518 35 7 316 S S 720 49 6 590 40 7 538 37 1 DN PN40 Carbon Steel 580 40 0 1 574 39 6 559 38 5 psi bar 304 S S 534 36 8 1 419 28 9
10. 28 0 to 400 inH2O continued Zero Static Pressure Effect per 0 1625 of span 300 psi 20 bar For URV below reference point 50 inH20 effect equals 50 inH20 2 or 0 0125 0 15 e span inH20 span mbar 0 0125 0 15 in of span Combined Zero and Span Static 0 30 of span Pressure Effect per 300 psi 20 For URV below reference point 50 inH20 effect equals bar 50 inH2O 125 mbar 0 15 0 15 E RAZO or 0 15 0 15 amba mbar in of span Stability 0 03 of URL per year Performance Under Rated Conditions Model STF132 0 to 100 psi Upper Range Limit psi 100 bar 7 Minimum Span psi 5 bar 0 35 Turndown Ratio 20 to 1 Zero Elevation and Suppression No limit except minimum span within 100 URL Specifications valid from 100 to 100 URL Accuracy Reference Includes In Analog Mode 0 10 of calibrated span or upper range value URV whichever is combined effects of linearity greater terminal based hysteresis and repeatability For URV calibrated below reference point 20 psi accuracy equals e Accuracy includes residual error 20 psi 14bar Sheraver ong Sicteccive 0 05 0 05 eens pai or 0 05 0 05 aata bar in of span dings feo oeeas In Digital Mode 0 075 of calibrated span or upper range value URV whichever is For FOUNDATION Fieldbus use greater terminal based Digital Mode specifications For HART use Analog Mode specifications 20 psi 1 4
11. FAN 50 inH20 125 mbar 0 0875 0 0625 Sannteo or 0 0875 0 0625 mma in of span Stability 0 015 of URL per year Performance specifications are based on reference conditions of 25 C 77 F zero 0 static pressure 10 to 55 RH and 316 Stainless Steel barrier diaphragm 34 ST 03 63 Page 9 Performance Under Rated Conditions Model STF13F 0 to 100 psi Upper Range Limit psi bar Minimum Span psi bar 100 7 5 0 35 Turndown Ratio 20 to 1 Zero Elevation and Suppression Accuracy Reference Includes combined effects of linearity hysteresis and repeatability e Accuracy includes residual error after averaging successive readings For FOUNDATION Fieldbus use Digital Mode specifications For HART use Analog Mode specifications Zero Temperature Effect per 28 C 50 F Combined Zero and Span Temperature Effect per 28 C 50 F Zero Static Pressure Effect per 1000 psi 70 bar Combined Zero and Span Static Pressure Effect per 1000 psi 70 bar Stability No limit except minimum span within 18 and 100 URL Specifications valid from 5 to 100 URL In Analog Mode 0 075 of calibrated span or upper range value URV whichever is greater terminal based For URV below reference point 15 psi accuracy equals 0 025 0 05 ara or 40 025 0 05 Dba span psi span bar in of span In Digital Mode 0 0625 of calibrated span or upper range value URV whichever
12. Industrial Automation amp Control 16404 North Black Canyon Hwy Phoenix AZ 85053 1 800 288 7491 In Canada The Honeywell Centre 155 Gordon Baker Rd North York Ontario M2H 3N7 1 800 461 0013 In Latin America Honeywell Inc 480 Sawgrass Corporate Parkway Suite 200 Sunrise FL 33325 954 845 2600 In Europe and Africa Honeywell S A Avenue du Bourget 1 1140 Brussels Belgium In Eastern Europe Honeywell Praha s r o Budejovicka 1 140 21 Prague 4 Czech Republic In the Middle East Honeywell Middle East Ltd Khalifa Street Sheikh Faisal Building Abu Dhabi U A E In Asia Honeywell Asia Pacific Inc Honeywell Building 17 Changi Business Park Central 1 Singapore 486073 Republic of Singapore In the Pacific Honeywell Pty Ltd 5 Thomas Holt Drive North Ryde NSW Australia 2113 61 2 9353 7000 In Japan Honeywell K K 14 6 Shibaura 1 chrome Minato ku Tokyo Japan 105 0023 Or visit Honeywell on the World Wide Web at http www honeywell com Specifications are subject to change without notice 34 ST 03 63 Page 18 Model Selection Guide 34 ST 16 21 Model Selection Guide 34 ST 16 21 Issue 46 Instructions Select the desired Key Number The arrow to the right marks the selection available Make one selection from each Table and II using the column below the proper arrow Select as many Table III options as desired if no options or approvals are desired specify 9X A e denotes unres
13. ST 3000 Smart Transmitter Honeywell 34 ST 03 63 2 08 Series 100 Flange Mounted Liquid Level Models STF128 0 to 400 inH20 STF132 0 to 100 psi STF12F 0 to 400 inH20 STF13F 0 to 100 psi STF14F 0 to 600 inH2O Introduction In 1983 Honeywell introduced the first Smart Pressure Transmitter the ST 3000 In 1989 Honeywell launched the first all digital bi directional protocol for smart field devices Today its ST 3000 Series 100 Flange mount Transmitters continue to bring proven smart technology to a wide spectrum of measurement applications Honeywell flange mount transmitters may be installed directly onto a tank flange and are offered with a variety of tank connections to include ANSI flange connections Typical applications are high accuracy level measurement in pressurized and un pressurized vessels in the chemical and hydrocarbon industries Honeywell flange mount transmitters demonstrate proven reliability in hundreds on installations in a wide variety of industries and applications All ST 3000 transmitters can provide a 4 20 mA output Honeywell Digitally Enhanced DE output HART output or FOUNDATION Fieldbus output When digitally integrated with Honeywell s Process Knowledge System EXPERION PKS ST 3000 instruments provide a more accurate process variable as well as advanced diagnostics Honeywell s high performance ST 3000 100 transmitters lead the industry in e Accuracy e Sta
14. an mbar in of span For FOUNDATION Fieldbus use In ech iae O of calibrated span or upper range value URV whichever is Digital Mode specifications For Seater termina based HART use Analog Mode For URV calibrated below reference point 25 inH2O accuracy equals specifications 25 inH20 0 025 0 05 Se or 0 025 0 05 62 5 mbar Eba in of span Zero Temperature Effect per In Analog Mode 0 2125 of span 28 C 50 F For URV below reference point 50 inH2O effect equals 50 inH20 0 0125 0 20 ran RgO or 0 0125 0 20 125 mbar Span mbar 1n of span In Digital Mode 0 20 of span For URV below reference point 50 inH2O effect equals 50 inH20 125 mbar 0 20 arnt or 0 20 anma in of span Combined Zero and Span In Analog Mode 0 40 of span Temperature Effect per 28 C For URV below reference point 50 inH20 effect equals 50 F f 50 inH20 125 mbar 0 20 0 20 span mbar Santo or 0 20 0 20 in of span In Digital Mode 0 375 of span For URV below reference point 50 inH20 effect equals 50 inH20 125 mbar 40 175 0 20 oan HO Or E0 1970 20 ama mbar in of span Performance specifications are based on reference conditions of 25 C 77 F zero 0 static pressure 10 to 55 RH and 316 Stainless Steel barrier diaphragm Table continued on next page gt 34 ST 03 63 Page 6 Performance Under Rated Conditions Model STF1
15. anty 4 years Lifetime Warranty 15 years Table Ill continued next page Model Selection Guide 34 ST 16 21 cont Availability TABLE Ill OPTIONS continued Siri Vv No azardous ocation approvals Class I Div 1 Groups A B C D Factory a Ignition Proof Class Il III Div 1 Groups E F G Mutual Class I Div 2 Groups A B C D oo Class Il Ill Div 1 Groups Intrinsically Safe AB C D E F G Explosion Proof Class I Div 1 Groups B C D Dust Ignition Proof Class Il Ill Div 1 Groups E F G Class Il Ill Div 1 Groups intrinsically Safe intrinsically Safe AB C D EF G Intrinsically Safe Ex ia IIC T4 eee Ex n IIC T6 T4 with SM option eee el eee eee ee ps eee Zone 0 1 2G EEXdlIC T5 T6 Flameproof Zone 1 els IP 66 67 a f a SDI 3 G EExnA lC TO ATEX Non Sparking Zone 2 Honeywell Enclosure IP 66 67 3N Multiple Marking Ex ll 1G EEx ia IIC T4 T5 T6 Int Safe Zone 0 1 or Ex ll2 G EExd IIC T5 T6 pow bbh Flameproof Zone 1 or Ex II 3 G EEx nA IIC T6 Honeywell Non Sparking Zone 2 Enclosure IP 66 67 Maa permor ocs ide de Brazil See ATEX installation requirements in the ST 3000 User s Manual The user must determine the type of protection required for installation of the equipment The user shall then check the box v adjacent to the type of protection used on the equipment certification nameplate Once a type of protection has been check TABLE IV Factory Identification XXXX
16. arbon Steel 304 SS or 316 SS STF12F STF13F STF14F 316L SS NOTE Mounting Flange is process wetted Fit Fluid Silicone oil or CTFE Chlorotrifluoroethylene Electronic Housing Epoxy Polyester hybrid paint Low Copper Aluminum Meets NEMA 4X watertight and NEMA 7 explosion proof Stainless Steel optional Process Connections All Models Process Head 1 4 inch NPT 1 2 inch NPT with adapter and DIN standard options STF128 STF132 Flange 2 3 or 4 inch Class 150 or 300 ANSI DN50 PN40 DN80 PN40 or DN100 PN40 DIN flange Extended Diaphragm 2 4 or 6 inches 50 101 152 mm long STF12F STF13F STF14F 2 or 3 inch Class 150 ANSI flange Wiring o Accepts up to 16 AWG 1 5 mm diameter Mounting o e See Figure 3 for typical flange mounting arrangement Table continued on next page 34 ST 03 63 Page 12 Physical and Approval Bodies continued Net Weight STF128 STF132 Flush or Extended Model 15 5 to 35 0 pounds 7 to 16 Kg depending on flange size STF12F STF13F STF14F 14 2 to 18 4 pounds 6 5 to 9 Kg depending on flange size Approval Bodies Explosion Proof Approved as Explosion Proof for Class Division 1 Groups A B C D locations Dust Ignition Proof Approved as Dust Ignition Proof for Class Il III Division 1 Groups E F G locations Intrincically Safe Approved as Intrinsically Safe for for Class I Il Ill Division 1 Groups A B C D E F G locations Nonincendive Ap
17. bar 0 025 0 05 Sean cai psi or 0 025 0 05 ene ar in of span For URV calibrated below reference point 20 psi accuracy equals Zero Temperature Effect per In Analog Mode 0 2125 of span 28 C 50 F For URV below reference point 30 psi effect equals 0 0125 0 20 sears or 0 0125 0 20 cantar in of span span psi span bar In Digital Mode 0 20 of span For URV below reference point 30 psi effect equals 30 psi 2 bar 0 20 sean pei psi or 0 20 spanta par in of span Performance specifications are based on reference conditions of 25 C 77 F zero 0 static pressure 10 to 55 RH and 316 Stainless Steel barrier diaphragm Table continued on next page gt 34 ST 03 63 Page 7 Performance Under Rated Conditions Model STF132 0 to 100 psi continued Combined Zero and Span lin Analog Mode 0 40 of span Temperature Effect per 28 C For URV below reference point 30 psi effect equals 50 F i 30 psi 2 bar 7 0 20 0 20 span asi or 0 20 0 20 nta bar in of span In Digital Mode 0 375 of span For URV below reference point 30 psi effect equals 30 psi 2 bar span psi span bar 0 175 0 20 or 0 175 0 20 in of span Zero Static Pressure Effect per 0 1625 of span 300 psi 20 bar For URV below reference point 30 psi effect equals 30 psi 2 bar 0 0125 0 15 Span pst Span bar or 0 0125 0 15 in of span Comb
18. bility e Reliability e Rangeability e Warranty Includes Lifetime Transmitters e Total Accuracy 0 0375 Stability 0 01 per year Reliability 470 years MTBF Rangeability 400 to 1 Lifetime Warranty 15 years 0 to 1000 mbar Specification and Oto7b 0 coca mbar Model Selection 0 to 7 bar Guide 0 to 1500 mbar Figure 1 Series 100 Flange Mounted Liquid Level Pressure Transmitters feature proven piezoresistive sensor technology The devices provide comprehensive self diagnostics to help users maintain high uptime meet regulatory requirements and attain high quality standards S100 transmitters are ideal for critical applications such as custody transfer of natural gas and energy and material balances where accuracy and stability are of the utmost importance Our commitment to Honeywell field instruments is based on seamless integration with our Honeywell system and the enhanced fault detection that the Honeywell DE protocol offers Honeywell instruments also offer us a better way of ensuring database integrity over simple analog instruments In addition Honeywell s high quality support has enabled us to better implement solutions to some of our more difficult problems We have used Honeywell differential pressure smart transmitters for the past eight years Based on their accuracy and low failure rates we are now targeting critical flow applications that require the robustness that these transmitters bring
19. d SM Option NE Two integral meter options are available An analog meter option ME is available with a 0 to 100 linear scale The Smart Meter option SM provides an LCD display for both analog and digital output and can be configured to display pressure in pre selected engineering units Lightning Protection Option LP A terminal block is available with circuitry that protects the transmitter from transient surges induced by nearby lightning strikes HART Protocol Compatibility Options HC and H6 Optional electronics modules for the ST 3000 provides HART Protocol compatibility in either HART 5 x or 6 x formats Transmitters with a HART Option are compatible with any HART enabled system that provides 5 x or 6 x format support FOUNDATION Fieldbus Option FF Equips transmitter with FF protocol for use in 31 25 kbit s FF networks See document 34 ST 03 72 for additional information on ST 3000 Fieldbus transmitters SIL2 SIL3 Certification Option SL This ST 3000 product is available for use with safety systems With the SL option we are fully certified to SIL 2 capability for single transmitters and SIL 3 capability for multiple transmitter use through TUV Nord Sys Tec GmbH amp Co KG We are in compliance with the following SIL standards IEC 61508 1 1998 IEC 61508 2 2000 IEC 61508 3 1998 This option provides software the meets the NAMUR NE43 requirements for failsafe software Transmitter
20. e 34 ST 03 63 Page 20 Model Selection Guide 34 ST 16 21 cont STF1xx ULE TABLE Ill OPTIONS Selection Analog only can be configured using appropriate Honeywell DE tool DE Protocol communications HART 5 x Protocol Compatible Electronics HART 6 x Protocol Compatible Electronics ae Fieldbus Communications Meter 0 100 Even 0 10 Square Root Smart Meter Custom Configuration of Smart Meter Local Zero amp Span Local Zero NAMUR Failsafe Software SIL 2 TUV Certified transmitter requires HC or H6 and WP options Lightning Protection Custom Calibration and I D in Memory Transmitter Configuration non Fieldbus Transmitter Configuration Fieldbus Write Protection Delivered in the enabled position Write Protection Delivered in the disabled position 316 SS Electronics Housing with M20 Conduit Connections 1 2 NPT to M20 316 SS Conduit Adapter BASEEFA EEx d IIC 1 2 NPT to 3 4 NPT 316 SS Conduit Adapter Stainless Steel Housing with M20 to 1 2 NPT 316 SS Conduit Adapter use for FM and CSA Approvals Stainless Steel Customer Wired On Tag 4 lines 28 characters per line customer supplied information Stainless Steel Customer Wired On Tag blank End Cap Live Circuit Warning Label in Spanish only with ATEX 3D End Cap Live Circuit Warning Label in Portuguese only with ATEX 3D End Cap Live Circuit Warning Label in Italian only with ATEX 3D End Cap Live Circuit Warning Label in German only with ATEX
21. hat service use 316 stainless steel wetted Process Heads Vent Drains are Teflon coated for lubricity 34 ST 03 63 Page 19 Model Selection Guide 34 ST 16 21 cont Availability TABLE Il FLANGE ASSEMBLY 3 ANSI Class 150 3 ANSI Class 300 DN80 PN40 DIN 4 ANSI Class 150 4 ANSI Class 300 Carbon Steel Carbon Steel DN100 PN40 DIN non wetted non wetted 2 ANSI Class 150 2 ANSI Class 300 DN50 PN40 DIN 3 ANSI Class 150 3 ANSI Class 300 DN80 PN40 DIN 4 ANSI Class 150 4 ANSI Class 300 304 SS 304 SS DN100 PN40 DIN non wetted non wetted 2 ANSI Class 150 ANSI Flanges have eel Pees 300 125 500 AARH Surface DNS0 PN40 DIN Finish 3 ANSI Class 150 3 ANSI Class 300 DN80 PN40 DIN 4 ANSI Class 150 4 ANSI Class 300 316 SS 304 SS DN100 PN40 DIN non wetted non wetted 2 ANSI Class 150 2 ANSI Class 300 DNS0 PN40 DIN 2 ANSI Class 150 w Vent Drain 3 ANSI Class 150 316L SS 304 SS w Vent Drain wetted wetted aii 3 ANSI Class 150 w o Vent Drain No Selection o Tr 316L SS Flush Design Hast C Gasket Ring wetted Monel ExendedDesign O f sass s hT No Selection of Flush o oF h Extensioni wetted O 2 inch 1 87 Inches P for 2 3 or 4 spud ep ora epee 6 inches EE No Selection No Selection else For part numbers and pricing information on Tank Spuds refer to page ST 91 Supplementary Accessories amp Kits Flang
22. ic Compatibility EMC Directive NAMUR NE 43 Compliance Transmitter failure information is generated when the measuring information is invalid or Option no longer present Failure information is transmitted as a current signal but outside the normal 4 20 mA measurement signal level Transmitter failure values are lt 3 6 mA and 221 0 mA The normal signal range is 2 3 8 mA and lt 20 5 mA SIL 2 3 Compliance SIL certified to IEC 61508 for non redundant use in SIL 2 related Safety Systems single use and for redundant multiple use in SIL 3 Safety Systems through TUV Nord Sys Tec GmbH amp Co KG under the following standards IEC61508 1 1998 IEC 61508 2 2000 IEC61508 3 1998 Lightning Protection Option Leakage Current 10 microamps max 42 4 VDC 93 C Code LP Impulse Rating 10 20 u sec 5 000 Amps 50 strikes 10 000 Amps 20 strikes rise decay 10 1000 u sec 250 Amps 1000 strikes 500 Amps 400 strikes Physical and Approval Bodies Parameter Description Barrier Diaphragms Material 316L SS Hastelloy C 276 Monel Wetted Gasket Ring Material Wetted 316 316L SS Hastelloy C 276 Monel Extension Tube Material 316 SS Process Head and Adapter 316 SS Carbon Steel Zinc plated Monel Hastelloy C 276 Flange Material Process Head Gaskets Teflon is standard Meter Body Bolting Carbon Steel or 316 SS NACE bolts Mounting Flange STF128 STF132 Flush or Extended Diaphragm Zinc Chromate plated C
23. ined Zero and Span Static 0 30 of span Pressure Effect per 300 psi 20 For URV below reference point 30 psi effect equals bar 30 psi 2 bar span psi span bar Stability 0 04 of URL per year 0 15 0 15 or 0 15 0 15 in of span Performance Under Rated Conditions Model STF12F EERE SS to 400 inH20 Upper Range Limit inH20 es 39 2 F 4 C is standard reference temperature for inH2O range mbar 25 Minimum Span inH20 Note Recommended minimum span in square root mode is 20 inH20 50 mbar mbar 5 Turndown Ratio 400 to 1 Zero Elevation and Suppression No limit except minimum span within 100 URL Specifications valid from 5 to 100 URL Accuracy Reference Includes In Analog Mode 0 075 of calibrated span or upper range value URV whichever is combined effects of linearity greater terminal based hysteresis and repeatability For URV below reference point 25 inH20 accuracy equals e Accuracy includes residual error 25 inH2O 62 mbar T a successive 0 025 0 05 span inH20 or 0 025 0 05 ssanimper In of span readings In Digital Mode 0 0625 of calibrated span or upper range value URV whichever is For FOUNDATION Fieldbus use greater terminal based Digital Mode specifications For i HART use Analog Mode For URV below reference point 25 inH20 accuracy equals 25 inH20 62 mbar specifications 6 or 0 0125 0 05 pan mbar 0 0125 0 05 EO in of
24. is greater terminal based For URV below reference point 15 psi accuracy equals 0 0125 0 05 ama or 0 0125 0 05 1 bar span psi aba in of span In Analog Mode 0 0625 of span For URV below reference point 30 psi effect equals 0 0125 0 05 ama or 0 0125 0 05 2 bar T in of span span psi In Digital Mode 0 05 of span For URV below reference point 30 psi effect equals 30 psi 2 bar 0 05 Sane Sai 02005 san Gar in of span In Analog Mode 0 10 of span For URV below reference point 30 psi effect equals 0 05 0 05 sare or 0 05 0 05 2 bar span psi span par in of span In Digital Mode 0 075 of span For URV below reference point 30 psi effect equals 30 psi 2 bar 0 025 0 05 erana a or 0 025 0 05 amta in of span 0 075 of span For URV below reference point 30 psi effect equals 0 0125 0 0625 rana or 0 0125 0 0625 2 bar enba in of span 0 15 of span For URV below reference point 30 psi effect equals 30 psi 2 bar A 0 0875 0 0625 saa pai or 0 0875 0 0625 emea i in of span 0 04 of URL per year Performance specifications are based on reference conditions of 25 C 77 F zero 0 static pressure 10 to 55 RH and 316 Stainless Steel barrier diaphragm 34 ST 03 63 Page 10 Performance Under Rated Conditions Model STF14F 0 to 600 inH2O Upper Range Limit inH20 6
25. ng a personal computer The toolkit enables configuration of devices before shipping or installation The SCT 3000 can operate in the offline mode to configure an unlimited number of devices The database can then be loaded down line during commissioning Features Choice of linear or square root output conformity is a simple configuration selection Direct digital integration with Experion PKS and other control systems provides local measurement accuracy to the system level without adding typical A D and D A converter inaccuracies Unique piezoresistive sensor automatically compensates input for temperature and static pressure Added smart features include configuring lower and upper range values simulating accurate analog output and selecting preprogrammed engineering units for display Smart transmitter capabilities with local or remote interfacing means significant manpower efficiency improvements in commissioning start up and ongoing maintenance functions 34 ST 03 63 Page 3 Specifications Operating Conditions All Models Parameter Reference Rated Condition Operative Limits Transportation and Condition Storage ee e Ff c f c F Ambient Temperature All models except STF14F 7742 40to85 40to185 40to93 40 to 200 55 to 125 67 to 257 STF14F 7742 40to85 40to185 40to85 40 to 185 55 to 125 67 to 257 Meter Body Temperature All models except STF14F 77
26. not have the CE mark or the manufacturer has the free choice of a module when the CE mark is required for pressures gt 200 bar 2 900 psig NOTE Pressure transmitters that are part of safety equipment for the protection of piping systems or vessel s from exceeding allowable pressure limits equipment with safety functions in accordance with Pressure Equipment Directive 97 23 EC article 1 2 1 3 require separate examination Flush design only Flush or pseudo flange design SA Australian 34 ST 03 63 Page 13 Attention Dotted area indicates use with closed tank with reference leg Maximum Level Variable Head H1 Minimum Level mounted LP Side vented to tank to atmosphere STR3006 Figure 3 Typical mounting arrangement for flange mounted liquid level transmitter 34 ST 03 63 Page 14 millimeters Reference Dimensions inches millimeters Reference Dimensions inches WITH SMART METER 82 9 94 9 WITH ANALOG METER 3 74 WITHOUT METER 53 1 65 1 WITHOUT METER 2 09 2 56 My 149 4 168 9 38876 65 REMOVAL CLEARANCE EXTERNAL GROUND B DIA OPTIONAL ADAPTER FOR 1 2 NPT NO OF BOLT Jipu NOLES ciRCLE 4 O N EGE ae oj Js GO 8 K o wW o iat o AG AIS Jo SIN 9N o ofoj No a N S a Q of w oOo a Aw AJ ofo 4 150 wo o 4
27. proved as Nonincendive for Class Division 2 Groups A B C D locations Factory Mutual Explosion Proof Approved as Explosion Proof for Class Division 1 Groups B C D locations Dust Ignition Proof Approved as Dust Ignition Proof for Class Il III Division 1 Groups E F G locations Intrincically Safe Approved as Intrinsically Safe for Class I Il Ill Division 1 Groups A B C D E F G locations Canadian Registration All ST 3000 model designs except SATG19L STG99L STG170 and STG180 have Number CRN been registered in all provinces and territories in Canada and are marked CRN 0F8914 5c Intrinsically Safe Zone 0 1 EEx ia IIC T4 T5 T6 FlameproofiZone 1 EEx d IIC T5 T6 enclosure IP 66 67 Non Sparking Zone 2 EEx nA IIC T6 enclosure IP 66 67 Multiple Markings _ Ex Il 1G EEx ia IIC T4 T5 T6 Extl2G EExd IIC T5 T6 Ex Il 3 G EEx nA IIC T6 Honeywell enclosure IP 66 67 Intrinsically Safe EX ia IIC T4 Non Sparking Ex n IIC T6 T4 with SM option INMETRO Brazil Flame Proof Zone 1 EXd IIC T5 Pressure Equipment Directive The ST 3000 pressure transmitters listed in this Specification have no pressurized 97 23 EC internal volume or have a pressurized internal volume rated less than 1 000 bar 14 500 psig and or have a maximum volume of less than 0 1 liter Therefore these transmitters are either not subject to the essential requirements of the directive 97 23 EC PED Annex 1 and shall
28. span Performance specifications are based on reference conditions of 25 C 77 F zero 0 static pressure 10 to 55 RH and 316 Stainless Steel barrier diaphragm Table continued on next page gt 34 ST 03 63 Page 8 Performance Under Rated Conditions Model STF12F 0 to 400 inH2O continued Zero Temperature Effect per In Analog Mode 0 0625 of span 28 C 50 F For URV below reference point 50 inH20 effect equals 50 inH20 125 mbar 20 0125 0 03 ana or 40 0125 0 08 Span mbar in of span In Digital Mode 0 05 of span For URV below reference point 50 inH20 effect equals 50 inH20 125 mbar 0 05 Santa or 0 05 aaa in of span Combined Zero and Span In Analog Mode 0 10 of span Temperature Effect per 28 C For URV below reference point 50 inH20 effect equals 50 F rie i span inH20 oray i span mbar in of span In Digital Mode 0 075 of span For URV below reference point 50 inH20 effect equals 50 inH20 125 mbar 0 025 0 05 Span mbar oan RAD or 0 025 0 05 in of span Zero Static Pressure Effect per 0 075 of span 1000 psi 70 bar For URV below reference point 50 inH20 effect equals 50 inH20 0 0125 0 0625 5 or 40 0125 0 0625 125 mbar span mbar Span inH20 in of span Combined Zero and Span Static 0 15 of span Pressure Effect per 1000 psi 70 For URV below reference point 50 inH20 effect equals
29. tricted availability A letter denotes restricted availability Restrictions follow Table IV Key Number Ill Optional Base STF models no longer include a default communications option All units now require the Important Note selection of a communication option from Table III AN DE HC H6 or FF KEY NUMBER Selection Availability 0 10 to 0 400 H20 0 25 to 0 1 000 mbar Compound Characterized STF128 0 5 to 0 100 psi 0 0 34 to 7 bar Compound Characterized E mg 0 1 to 0 400 H20 0 2 5 to 0 1 000 mbar STF12F y 0 5 to 0 100 psi 0 0 34 to 0 7 bar w a 0 25 to 0 600 H20 0 62 2 to 0 1 500 mbar o STF14F y TABLE METER BODY Barrier Diaphrm Diaphrm Plate wetted wetted 316L SS Carbon 316L SS Steel Hast C 316 SS Monel Flush 316L SS 316L SS 316 SS Hast C 316L SS Hast C Hast C Monel Monel Materials of te Construction Carbon 316L SS Steel Hast C Extended 316 SS 316L SS 316L SS 316L ked 316 31688 Hast ked Carbon 316L SS Hast C Pseudo Steel Monel Flange 3216 99 316L Ea NA WA 316 31855 Hast C Ea Extension Valve on wetted Ref Head Fill Fluid Silicone Meter Body amp Flange CTFE 1 4 NPT High Pressure Side Process Connection 1 4 NPT Low Pressure Side 1 2 NPT with Adapter High Pressure Side 1 2 NPT with Adapter Low Pressure Side Carbon Steel heads are zinc plated and not recommended for water service due to hydrogen migration For t
Download Pdf Manuals
Related Search
Related Contents
Heart Tracker Professional User`s Manual - Bio Charlie Hebdo - Médiathèque départementale Single-sided LED Basketball Game Clock and Shot Clock - AV-iQ Samsung PL90 Felhasználói kézikönyv REPUBLIQUE DU CAMEROUN REPUBLIC OF CAMEROUN CBA-1200AT-SP-V1 取扱説明書ダウンロード LASER LOCK LIVE MAPPING SYSTEM Lenco LED-2213 取扱説明書 Copyright © All rights reserved.