Home
P007380 Rev. C - Guardian Telecom Inc.
Contents
1. vn ed Yd am 388 MAIN POWER GND J1 3 5 7 9 11 Figure 1 Wiring 4 Guardian Telecom Inc Installation and Operation PTJ Page Talk Junction Box L 8 0 203 2mm 12 75 324 0mm Figure 2 Dimensions L I _ 8 0 203 2mm 12 75 324 0mm Figure 3 Mounting Page 5 Guardian Telecom Inc Installation and Operation PTJ Page Talk Junction Box WIRE TERMINATION 16 CONDUCTOR CABLE ASSIGNMENT WIRE GAUGE J1 J3 45 J7 J9 J11 14 AWG POWER 210345778 POWER J1 J3 J5 J7 J9 J11 14 AWG J1 J3 J5 J7 J9 J11 14 AWG N A AMBIENT NOICE N A N A J2 J4 J6 J8 J10 J12 1A RED 18 AWG CHANNEL 1 J2 J4 J6 J8 J10 J12 1B L BROWN 18 AWG SPEAKER J15 J15 J13 J13 42 J4 J6 J8 J10 J12 4A BROWN 18 AWG CHANNEL 4 J2 J4 J6 J8 J10 J12 4B L BROWN 18 AWG J2 J4 J6 J8 J10 J12 5A YELLOW 18 AWG CHANNEL 5 42 J4 J6 J8 J10 J12 5A L BROWN YELLOW 18 AWG GROUP MUTING J2 J4 J6 J8 J10 J12 MUTE ORANGE SPARE exe orange NOTES 1 CHANNELS 2 TO 5 CONNECTIONS REMAIN EMPTY FOR SINGLE TALK HOOKUP 2 IF THE CABLE IS 18 CONDUCTOR TYPE TWO WIRES WILL BE WHITE RED AND WHITE BLACK DO NOT CUT THESE WIRES CLOSE TO THE CABLE ENTRY CONNECT WHITE RED TO ALL OTHER WHITE RED WIRES AND WHITE BLACK TO ALL OTHER WHITE BLACK WIRES AND INSUL
2. Cable Listing Part No Description Part No Description P006183 2 Conductor 18AWG Armored Speaker P005863 8 Conductor Armored Single Line System P006184 2 Conductor 18AWG Standard Speaker P005916 Conductor Standard Single Line System P006217 4 Conductor 18AWG Armored Speaker P005366 16 Conductor Armored Five Line System P006216 4 Conductor 18AWG Standard Speaker P005219 16 Conductor Standard Five Line System P006218 17 Conductor Armored Five Line System Page 10 Guardian Telecom Inc Installation and Operation PTJ Page Talk Junction Box Warranty Guardian Telecom warrants your product to be free of defects in material and workmanship for a period of one year Guardian Telecom will repair or replace any defective unit that is under warranty free of charge This warranty is null and void if any non authorized modifications have been made to this product or if it has been subjected to misuse neglect or accident This warranty covers bench repairs only such repairs must be made at Guardian Telecom or an authorized service depot Guardian Telecom is not responsible for costs incurred for on site service calls freight or brokerage A return authorization must be obtained prior to warranty claims or repairs Disclaimer The products covered by this manual are designed for use in Industrial Environments and or Hazardous Locations Due to the range of possible applications for these instruments the manufacturer
3. LIGHT BROWN RED LINE 1B VIOLET LINE 2A LIGHT BROWN VIOLET LINE 2B BLUE LINE 3A LIGHT BROWN BLUE LINE 3B BROWN LINE 4A LIGHT BROWN BROWN LINE 4B YELLOW LINE 5A LIGHT BROWN YELLOW LINE 5B SAFETY GROUND LINE NEUTRAL LINE LIVE Note the 18 AWG ORANGE wire is not terminated and is used for Page Talk local mute Figure 7 Select System connector wiring for 18 wires Notes e The above colour scheme is for background marking For example BLUE REDisa blue background with a red marking e Terminal and Breaker mean Terminal Block BUS COMBICOM CONNECTOR Figure 8 Combicon 14 pin connector top view Page 8 Guardian Telecom Inc Installation and Operation PTJ Page Talk Junction Box Installing the Junction Box WARNING high voltages are present in this equipment when it is connected to the power source Follow all appropriate electrical codes and use only approved electrical fittings for the installation Punch holes in the sides of the enclosure for cable fittings Install suitable fittings in the cable entrances Choose a wall location that is free of obstructions and permits space for See Figure 2 conduit or wire Dimensions Ensure mounting can support 6 6 lbs 3 kg with module installed and any additional foreseeable load Use the ho
4. ATE THEM Figure 4 Electrical Connections Page 6 Guardian Telecom Inc Installation and Operation PTJ Page Talk Junction Box Figure 5 Bus connector wiring at SJB relays SJB CTI and LET The Page Talk Communications cable is normally sheathed in a bright yellow plastic armored jacket In the Communications cable there are e 1 15 of the 18 gauge wires 30of 14 gauge wires The three 14 gauge wires used for AC are ground AC neutral and AC live and these are not connected on the Bus connector The AC wires are terminated at either a terminal strip or an AC breaker mounted on a DIN rail in the cabinet WIRE TERMINATION FOR 16 CONDUCTORS COLOUR OF 18 AWG WIRE ABREV FUNCTION ORANGE TESTA JUMPER TO 12 4B TEST B BLUE RED PAGE A RED BLUE PAGE B RED LINE 1A LIGHT BROWN RED LINE 1B VIOLET LINE 2A LIGHT BROWN VIOLET LINE 2B BLUE LINE 3A LIGHT BROWN BLUE LINE 3B BROWN LINE 4A LIGHT BROWN BROWN LINE 4B YELLOW LINE 5A LIGHT BROWN YELLOW LINE 5B SAFETY GROUND LINE NEUTRAL LINE LIVE Note the 18 AWG ORANGE wire on pin 1 is not used for Page Talk local mute Figure 6 Select System connector wiring for 16 wires Page 7 Guardian Telecom Inc Installation and Operation PTJ Page Talk Junction Bok WIRE TERMINATION FOR 18 CONDUCTORS COLOUR OF 18 AWG WIRE FUNCTION WHITE RED TESTA WHITE BLACK TEST B BLUE RED PAGE A RED BLUE PAGE B RED LINE 1A
5. Guardian KB CE Telecom CONNECTED PROTECTED Page Talk Indoor Junction Box Model PTJ Installation 4 Operation P007380 Rev C 150318 8 21 2015 9 41 AM Ph 403 258 3100 1 email info guardiantelecom com www guardiantelecom com Guardian Telecom Inc Installation and Operation PTJ Page Talk Junction Box Table of Contents Package tel sata 2 Replacement ete i 2 OVSIVIGW 3 EA een 3 Installing the Junction Box ee seen 9 Product Specifications oda eas 10 Installation Cable Listing uc ode 10 11 Disclaimer aa 11 Warning 11 Service Telephone 11 MEE MMC E A 11 Guardian Product Return feier 12 A DEI te 4 Figure 2 DIMENSIONS uitio tent real 5 Figure 3 MOUNTING unsere ee 5 Figure 4 Electrical Connections 6 Figure 5 Bus connector wiring at SUB relays SJB CTI and LET 7 Figure 6 Select System connector wiring for 16 wires 7 Figure 7 Select System connector wiring for 18 wires 8 Figure 8 Combicon 14 pin
6. al we would appreciate hearing from you Page 11 Guardian Telecom Inc Installation and Operation PTJ Page Talk Junction Bok Guardian Product Return Guardian products have been guality tested in full working order when shipped from the factory given the rugged nature of these products shipping is not expected to damage a unit In the unlikely event of a malfunction Guardian follows the three step procedure below Step I On Site Correction e The most common source of difficulties with a new product is improper installation in one of two ways incorrect wiring connections or connection to an incorrect power source e Product wiring needs to be properly connected to the on site wiring Correct wiring instructions are shown in the user manual included with the product Step Il Return Materials Authorization RMA e When a product has been installed following user manual instructions and the unit fails to operate the user must contact Guardian Telecom to obtain authorization to return the product This can be done by completing a RMA form online at www guardiantelecom com or by calling the service telephone number given in this manual e After providing information on the product the owner and the nature of the problem Guardian will issue a RMA number to be shown on documentation returned with the product e In addition to the RMA number shipping documents should include name address and telepho
7. connector top view 8 Package Contents One 1 P8700 Page Talk Indoor Junction Box One 1 Installation amp Operation Manual Replacement Parts Part No Description P006736 PCB Assembly Page 2 Guardian Telecom Inc Installation and Operation PTJ Page Talk Junction Box Overview Page Talk Junction Box Guardian s Page Talk Systems provide reliable and easy to use paging and communication within industrial environments such as plants mills and factories Individuals can be paged from any station and two or more persons can communicate on any available line The PTJ Terminal Junction Box described in this manual provides a convenient method of branching out from one to five legs of Page Talk system wiring from one location The unit also includes one system test port Features Construction e Fiberglass reinforced polyester enclosure self extinguishing and halogen free Cable Entrances e Solid surfaces for punching holes to customer requirements Mounting e Mounts to any vertical surface Connectors e removable screw and plug Combicon connectors allow for ease of installation simply screw wires into plug and reinsert plug into PCB socket Capacity e Six cables 1 in 5 out Page 3 Installation and Operation PTJ Page Talk Junction Box Guardian Telecom Inc J2 4 6 8 10 12 PAGE amp TALK CHANNELS e ae Y ac amp we amp
8. ne number of the owner along with contact information for the person responsible for the repair and or the user who identified the malfunction e Where a product is being returned for repair from outside of Canada customs documentation must show the product s serial number date of export date of purchase and a notation that the equipment is Canadian goods returning Step III Factory Authorized Service e Once received each product is carefully inspected and tested If the product is under warranty repairs are completed and the product returned to the owner generally within five working days of receipt by the factory A product that has been subjected to misuse neglect or accident or is beyond the warranty period will be evaluated The service department will provide the owner s representative with a repair cost estimate Once approved repairs are completed and the product returned generally within five working days Page 12 Guardian Telecom Inc Notes Installation and Operation Page Talk Junction Model No Part No Serial No Date of Purchase Page 13 THIS PAGE INTENTIONALLY LEFT BLANK THIS PAGE INTENTIONALLY LEFT BLANK ISO 9001 CERTIFIED Guardian Telecom Inc Toll free 1 800 363 8010 Phone 403 258 3100 Fax 403 253 4967 www guardiantelec
9. om com E mail sales quardiantelecom com Click to open message box CONNECTED PROTECTED Guardian Telecom Inc 2015
10. using to locate and drill holes for mounting screws Secure the unit to the wall Ensure that none of the electrical connection circuits are live Bring cable s into the enclosure through the conduit entrance s and attach See Figure 4 Electrical individual wires to the Combicon connector s Make Talk channel Connections connections to terminals 1A and 1B for a single line station Plug the connector s into the receptacle s on the interface board Ensure all connections are secure Page 9 Guardian Telecom Inc Installation and Operation PTJ Page Talk Junction Box Product Specifications ENVIRONMENTAL WEATHER TIGHT ENCLOSURE GASKET DUST TIGHT ENCLOSURE GASKET TEMPERATURE RANGE 58 to 300 F 50 to 150 C INGRESS PROTECTION NEMA IP66 4X RATING MECHANICAL CAPACITY SIX CABLES TO COMBICON CONNECTORS CONSTRUCTION FIBERGLASS REINFORCED POLYESTER ENCLOSURE SELF EXTINGUISHING AND HALOGEN FREE DIMENSIONS W D 13 33 X 11 3X 5 59 INCHES 338 X 287 X 142 MM NET WEIGHT 6 6 LBS 3KG MOUNTING VERTICAL SURFACE WIRING ACCESS SOLID SURFACES FOR PUNCHING HOLES TO CUSTOMER REQUIREMENTS COMPLIANCE CSA and 5 CSA 1289924 Canada Class Division 2 Groups A Class Groups E F G T6 United States Class Division 2 Groups A B C D Class Groups E F Class Zone 2 T6 ELECTRICAL SAFETY C 60950 Installation
11. will not be responsible for damages or losses of any kind suffered as a result of the use of this product including consequential damages Warning High voltages may be present in this product ensure that power is removed before installing performing maintenance or making repairs Service Telephone Number 1 800 363 8010 Toll Free in North America Guardian Telecom provides a customer service telephone number which is toll free within North America If you need assistance when installing or operating this product please call the toll free telephone number between regular business hours 7 30AM 5 00PM Mountain Standard Time If you are calling outside of regular business hours please leave a detailed message and a member of Guardian Telecom s Service Department will return your call as soon as possible If your product requires service Guardian personnel will supply you with an RMA return materials authorization number over the telephone or through our web site product return page This number must be included with your return address and the name of the person to contact Guardian Telecom Inc Toll free 1 800 363 8010 Ph 403 258 3100 Fax 403 253 4967 www guardiantelecom com Feedback Guardian Telecom continually strives to make reliable durable and easy to use products If you as an installer or user of our equipment have any suggestions for improvements to this or any of our products or documents including this manu