Home
Spectrum Analyzer
Contents
1. 95 95 gt CALCulate LIMit lt n gt MARKeE eeeenrnn 95 CALCulate LIMit MODE CALCulate LIMit STATe gt CALCulate LIMit lt n gt TRACE eee 96 CALCulate LIMit TYPE CALCulate MARKer AOFF CALCulate MARKer lt n gt FCOunt RESolution 97 CALCulate MARKercn FCOuntRESolution AUTO CALCu CALCu CALCu CALCu CALCu CALCu CALCu CALCu CALCu CALCu CALCulate MARKer PEAK THReshold 102 CALCulate MARKer PEAK THReshold STATe 103 CALCulate M ARKercn SET CALCulate MARKer lt n gt STATe CALCulate M ARKetr TABLe STATe eee 104 65 GW INSTEK GSP 9300 Programming Manual CONFigure Commands DISPlay Commands 66 CALCulate MARKer lt n gt TRACE eee CALCulate MARKercn2 TRACe AUTO CALCulate MARKer lt n gt TYPE ss ae CALCulate MARKern X eee CALGCulateeMARKet n Y urieni 06 CALCu CALCu CALCu CALCu ih CALCulate NDB BAND width BWIDth 08 CALCulate NORMalize STATe eee CALCulate OCBW STATe eee CALCulate OCBW BAND width BWIDth CALCulate OCBW CHbPowet
2. Set SYSTem CLOCk n STATe Description Turns the selected wake up clock on off Syntax SYSTem CLOCk n STATe 1 Query Syntax SYSTem CLOCk n STATe Parameter n Wake up clock number 1 to 7 0 Turn the wake up clock off 1 Turn the wake up clock on OFF Turn the wake up clock off ON Turn the wake up clock off Return parameter 0 The wake up clock is off 1 The wake up clock is on Example SYST CLOCT STATE 1 Set SYSTem CLOCk n TIME Description Sets the alarm time for the selected wake up clock Syntax SYSTem CLOCk n TIME lt hour gt lt minute gt Query Syntax SYSTem CLOCk n TIME Parameter hour NRI Sets the alarm hour Return parameter minute NRI Sets the alarm minute n Wake up clock number 1 to 7 Example SYST CLOC1 TIME 20 50 SYSTem COM Municate GPIB SELF ADDRess Set Description Sets the GPIB address Syntax SYSTem COM Municate GPIB SELF ADDRess lt integer gt GW INSTEK REMOTE CONTROL Parameter lt integer gt 0 to 30 Example SYST COMM GPIB ADDR 10 SYSTem COM Municate LAN Reset Set Description Reset the LAN configuration and reboot Syntax SYSTem COMMunicate LANReset Example SYST COMM LANR SYSTem COMMunicate SERial RECeive BAUD Set Description Sets the RS232 Baud rate Syntax SYSTem COMMunicate SERial RECeive BAUD integer Parameter
3. Example CALC MARKT FCO RES gt 1 0e 3 CALCulate MARKer n FCOunt Set RESolution AUTO Description Sets the frequency counter resolution Auto setting on off Syntax CALCulate MARKer lt n gt FCOunt RESolution AUTO ON OFF 1 0 Query Syntax CALCulate MARKer n FCOunt RESolution AUTO Parameter n lt NR1 gt Marker number 1 6 0 Auto is off 1 Auto is on OFF Auto is off ON Auto is on Return parameter 0 Auto is off Auto is on Example CALC MARKT FCO RES AUTO Set CALCulate MARKer lt n gt FCOunt STATe Description Sets or queries the state of the frequency counter function Syntax CALCulate MARKer lt n gt FCOunt STATe ON OFF 1 0 Query Syntax CALCulate MARKer lt n gt FCOunt STATe 98 GW INSTEK REMOTE CONTROL Parameter lt n gt lt NR1 gt Marker number 1 6 0 Turn frequency counter off 1 Turn frequency counter on OFF Turn frequency counter off ON Turn frequency counter on Return parameter 0 Frequency counter is off 1 Frequency counter is on Example CALC MARKer1 FCO STAT 1 CALCulate MARKer lt n gt FCOunt X Description Returns the counter frequency of the selected marker in Hz Query Syntax CALCulate MARKer lt n gt FCOunt X Parameter lt n gt lt NR1 gt Marker number 1 6 Return parameter lt freq gt lt NR3 gt Frequency in Hz Example CALC MARK1 FCO X gt 2 0083e 8 Set CALCulate MARKer lt n gt NO1Se STAT
4. Parameter IMMediate Free run trigger Return parameter EXTernal External trigger Example TRIG PMET SOUR IMM Set TRIGger SEQuence SOURce Description Sets the triggering source to immediate external or video Syntax TRIGger SEQuence SOURce IMMediate EXTernal VIDeo Query Syntax TRIGger SEQuence SOURce Parameter IMMediate Free run trigger Return parameter EXTernal External trigger VIDeo Video trigger Example TRIG SOUR IMM Set TRIGger SEQuence VIDeo FREQuency Description Sets the video trigger frequency Syntax TRIGger SEQuence VIDeo FREQuency freq Query Syntax TRIGger SEQuence VIDeo FREQuency Parameter freq lt NRf gt Return parameter lt NR3 gt Hz Example TRIG VID FREQ gt 2 5e 6 Set TRIGger SEQuence VIDeo LEVel Description Sets the video trigger level Syntax TRIGger SEQuence VIDeo LEVel lt ampl gt Query Syntax TRIGger SEQuence VIDeo LEVel 224 GW INSTEK REMOTE CONTROL Parameter ampl lt NRf gt power or voltage Return parameter lt NR3 gt Example STRIG VID LEV 10 Set TRIGger SEQuence VIDeo SLOPe Description Sets the video trigger slope Syntax TRIGger SEQuence VIDeo SLOPe POSitive NEGative Query Syntax TRIGger SEQuence VIDeo SLOPe Parameter POSitive Positive slope Return parameter NEGative Negative slope Example TRIG VID SLOP POS 225 GW INSTEK GSP 9300 Programmi
5. Parameter lt n gt lt NR1 gt adjacent channel 1 3 Return parameter 0 lt boolean gt Pass 1 lt boolean gt Fail Query Example CALC ACPR ACH1 LLIM FAIL gt 0 CALCulate ACPR ACHannel lt n gt LOWer Description Returns the ACPR adjacent channel power ratio in dB calculated for the selected lower adjacent channel Query Syntax CALCulate ACPR ACHannel lt n gt LOWer Parameter lt n gt lt NR1 gt adjacent channel 1 3 Return parameter lt NR3 gt Power ratio in dB Query Example CALC ACPR ACH1 LOW gt 1 801e 01 CALCulate ACPR ACHannel n UPPer Description Returns the ACPR adjacent channel power ratio in dB calculated for the selected higher adjacent channel Query Syntax CALCulate ACPR ACHannel lt n gt UPPer 80 GW INSTEK REMOTE CONTROL Parameter lt n gt lt NR1 gt adjacent channel 1 3 Return parameter lt NR3 gt Power ratio in dB Query Example CALC ACPR ACH1 UPP gt 1 921e 01 Set CALCulate ACPR ACHannel lt n gt STATe Description Sets or queries the state of the selected adjacent channel Syntax CALCulate ACPR ACHannel lt n gt STATe OFF ON 0 1 Query Syntax CALCulate ACPR ACHannel lt n gt STATe Parameter lt n gt lt NR1 gt adjacent channel 1 3 0 Disable the selected channel 1 Enable the selected channel OFF Disable the selected channel ON Enable the selected channel Return parameter 0 The selected channe
6. DEMod FILTet LPASS DEMOd IEBW DEMod SQUelch LEVel DETector FUNCtion DETectorFUNCton AUTO SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe ER EL kend bemid hamad Kon aed bemad kansal boana rd id bd icd nd c basal basa ed ecd bamad ned e ksal d bend acd bd basal ac 143 GW INSTEK GSP 9300 Programming Manual 144 SENSe EMIFilter S T A Te SENSe EMIFilter BA NDwidth BWIDth RESolution tritt tent petes SENSe FREQuency CENTet eee SENSe FREQuency CENTet STEP SENSe FRE Quency CENTer STEP AUTO m SENSe FREQuency OFTSet eee SENSe FREQuency SPAN FULL i SENSe FREQuency SPAN PREVious SENSe FREQuency STOPD eee eee SENSe HARMonic FUNDamental FREQuency SENSe HARMonic NUMBer SENSe LIMit lt n gt DELete ss SENSe JITTer OFFSecSTAREt eee NDB BANDwidth BWIDth E SENS
7. Example DISP TRAC Y RLEV OFFS 5 0e 1 dB DISPlay WINDow TRACe Y SCALe Set SPACing Description Sets or queries the type of scale logarithmic or linear Syntax DISPlay WINDow TRACe Y SCALe SPACing LINear LOGarithmic Query Syntax DISPlay WINDow TRACe Y SCALe SPACing Parameter LINear Linear scale Return parameter LOGarithmic Logarithmic scale Example DISP TRAC Y SPAC LOG DISPlay WINDow TRACe Y SCALe Set STATe Description Turns the on screen scale on off or queries its state Syntax DISPlay WINDow TRACe Y SCALe STATe OFF ON O 1 Query Syntax DISPlay WINDow TRACe Y SCALe STATe Parameter 0 Turn scale off Turn scale on OFF Turn scale off ON Turn scale on Return parameter 0 Scale is off Scale is on Example DISP TRAC Y STAT ON 129 GW INSTEK GSP 9300 Programming Manual DISPlay SPECtrogram DELTA INVerse TIM E Description Returns the frequency delta between the refence and delta marker in the spectrogram display view Query syntax DISPlay SPECtrogram DELTA INVerse TIME Return parameter lt NR3 gt Returns the frequency delta in kHz Example DISP SPEC DELTA INV TIME gt 1 233e 06 GW INSTEK REMOTE CONTROL INITiate Commands INITiate CON Tinuous eere nnne 131 NI Tiate IMMedratel tte ete epe int 131 Set INITiate CONTinuous Description Sets the sweep mode to conti
8. 180 SENSe SEMask OFFSet lt n gt STOP ABSolute 180 SENSe SEMask OFFSet lt n gt STOP ABSolute COUPE R 181 SENSe SEMask OFFSet lt n gt STOP RELative 181 SOURce commands SENSe SEMask OFFSet lt n gt STOP RELative SENSe SEMask W3GPP TDD TRANsmit MODE 186 SENSe SEMask WIMax CHANnel SENSe SEQuence lt n gt DELete SENSe SWEep EGATe DELay SENSe SWEep EGATe LENG th eee 5 5 SENSe SWEep MODE SENSe SWEep TIME ss SSENSe SWEep TIME AUTO SENSe TOLREFerence SENSe TOLLIMit SSOURce POWer LEVel IMMediate AMPLitude 191 SOURce POWer LE Vel IMMediate AMPLitude Ded cesses atts 191 SOURce POWer LEVel IMMediate A MPLitude SA a d 192 SSOURce POWer MODE SOURce POWer SWEep 71 GW INSTEK GSP 9300 Programming Manual SYSTem 5 commands SYSTem CLOCk lt n gt DATE SYSTem CLOCk lt n gt MODE SYSTem CLOCk lt n gt STATe SYSTem CLOCK lt n gt TIME scssi irii SYSTem CO MMunicate GPIB SELF ADDRess 196 SYST
9. Description Turns the selected correction set on off or queries its state Syntax SENSe CORRection CSET lt n gt STATe OFF ON 0 1 Query Syntax SENSe CORRection CSET lt n gt STATe Parameter 0 Turn turn the selected correction set off 1 Turn turn the selected correction set on OFF Turn turn the selected correction set off ON Turn turn the selected correction set on n lt NR1 gt correction set number Return parameter 0 The selected correction set is off 1 The selected correction set is on Example CORR CSETI STAT ON 155 GW INSTEK GSP 9300 Programming Manual SENSe CORRection CSET lt n gt DELete Set Description Deletes the chosen correction set Syntax SENSe CORRection CSET lt n gt DELete Parameter lt n gt lt NR1 gt correction set number Example CORR CSETT DEL 2 Set SENSe CSO CHANnel SPACe Description Sets the channel space bandwidth for CSO measurements Syntax SENSe CSO CHANnel SPACe freq Query Syntax SENSe CSO CHANnel SPACe Parameter freq lt NRf gt Return parameter lt NR3 gt Hz Example CSO CHAN SPAC 6 0e 6 Set SENSe CTB CHANnel SPACe Description Sets the channel space bandwidth for CTB measurements Syntax SENSe CTB CHANnel SPACe freq Query Syntax SENSe CTB CHANnel SPACe Parameter lt freq gt lt NRf gt Return parameter lt NR3 gt Hz Example CTB CHAN SPAC 6 0e 6 GW INSTEK REMOTE CONTRO
10. Common Type Description Example input Parameters lt Boolean gt Boolean logic 0 1 NRI integers 0 1 2 3 NR2 decimal 0 1 3 14 8 5 numbers lt NR3 gt floating point 4 5e 1 825e 1 lt NRf gt any of NR1 2 3 1 1 5 4 5e 1 lt freq gt Input lt limit num gt lt point gt lt offset gt lt rel_ampl gt 52 lt NRf gt unit 25 mhz Unit kHz MHz GHz Note The unit can be omitted unit defaults to Hz Return lt NR3 gt 2 5e 5 Note Units Hz NR1 NR1 Input lt NRf gt unit 30 db Note The unit can be omitted unit defaults to dB Return lt NR3 gt 3 0e 1 Note Units dB Input lt NRf gt unit 20 db Note The unit can be omitted unit defaults to dB Return lt NR3 gt 2 0e 1 GW INSTEK REMOTE CONTROL lt ampl gt lt trace name gt lt time gt lt ip address gt Note Units dB Input 30 mv NR3 unit type Note The unit can be omitted Unit defaults to current y axis unit Return lt NR3 gt 3 0e 2 Note Units current y axis unit lt NRI1 gt tracel Input lt NR3 gt unit 2 3e 6 ms Unit ms ns ps ks Note The unit can be omitted unit defaults to seconds Return lt NR3 gt 3 0e 2 Note Units 7 seconds String 172 16 20 20 Message Terminator 2 Line feed code 0x0A 53 GW INSTEK GSP 9300 Programming Manual Status Registers Status Regis
11. 87 CALCulate DEMOod AM RESult CURRent CALCulate DEMOG AM RESultMINimum 88 CALCulate DEMod AM RESult MA Ximum 88 5 CALCulate DEMod EARPhone STATe 77 GW INSTEK GSP 9300 Programming Manual CALCulate DEMOod FM RESult CURRent 89 CALCulate DEMOd EM RESult MINimum 90 CALCulate DEMOd FM RESult MA Ximum 90 CALCulate DEMOd EM STATe eee 91 CALQulateDEMOd RESet teet 91 CALCulate HARMonic DISTortion es 91 CALCulate HARMonic RESult eee 92 CALCulate HARMonic STATe GALCulate LE T Ter ST ATe ettet CALCulate JITTer CARRier POWere eee 93 CALDCulate T Ter PHASE astitit tintas 93 CALCulate JTT Ter TIME as sese teen inertes 93 CALCulate _LIMit lt n gt CLEar CALCulate LIMit lt n gt DATA eee CALGulateLIMit FAIL uiii teet osten tee 94 CALCulate LIMit LOW oo cccccccccsccsscescesecssecsesesessesssesesesees 95 CALCulate LIMIit HIGH eere 95 CALCulate LIMit n MARKet eee 95 CALCulate LIMit zMODE eere eere CALCulate LIMItSTATTe eese eerte CALCulate LIMit lt n gt TRACe CALCulate LIMit TYPE CALCulate MARKer A OFF eene CALCulate
12. Description Returns the current measurement results for AM demodulation as a comma separated string Query Syntax CALCulate DEMod AM RESult CURRent Return parameter depth rate power offset sinad depth Modulation depth in 96 rate Modulation rate in Hz power Carrier power in the current Y axis units offset Carrier frequency offset in Hz sinad Signal to noise and distortion ratio in dB Query Example CALC DEM AM RES CURR gt 9 840e 1 1 02e 2 1 12e 1 3 21e 1 1 61e 1 87 GW INSTEK GSP 9300 Programming Manual CALCulate DEMod AM RESult MINimum Description Returns the minimum recorded measurement results for AM demodulation as a comma separated string Query Syntax CALCulate DEMod AM RESult MINimum Return parameter lt depth rate power offset sinad gt depth Modulation depth in rate Modulation rate in Hz power Carrier power in the current Y axis units offset Carrier frequency offset in Hz sinad Signal to noise and distortion ratio in dB Query Example CALC DEM AM RES MIN gt 9 840e 1 1 02e 2 1 12e 1 3 21e 1 1 61e 1 CALCulate DEMod AM RESult MAXimum Description Returns the maximum recorded measurement results for AM demodulation as a comma separated string Query Syntax CALCulate DEMod AM RESult MAXimum Return parameter lt depth rate power offset sinad gt depth Modulation depth in rate Modulation rate in Hz power Carrier
13. ID SCPI Command Clear Window RST IDN sSYST ERR Enter SCPI command or query Write Red Write amp Read Get Image The Get Image page allows the browser to remotely capture a screenshot of the GSP 9300 display For further details please see the programming Note manual available on the GW Instek web site www gwinstek com 39 GW INSTEK GSP 9300 Programming Manual GPIB Function Check Background To test the GPIB functionality National Instruments Measurement and Automation Explorer can be used This program is available on the NI website www ni com via a search for the VISA Run time Engine page or downloads at the following URL http www ni com visa Requirements Operating System Windows XP 7 8 Functionality 1 check 2 3 Start the NI Measurement and Automation Explorer MAX program Using Windows press Start gt All Programs gt National Instruments gt Measurement amp Automation Measurement amp Automation Explorer Loading plug ins Version 5 5 1999 2013 National Instruments All rights reserved From the Configuration panel access My System Devices and Interfaces gt GPIBX gt Press Scan for Instruments GW INSTEK REMOTE CONTROL T GPIB3 GPIB USB HS Measurement amp Automation Explorer File Edit View Tools Help 4 EA My Systef H ri 5 A Scan for YAstruments 9 De
14. NRI Return parameter Example AVER COUN 20 Set SENSe AVERage STATe Description Turns the Average function on off or queries its state Syntax SENSe AVERage STATe OFFJON 0 1 Query Syntax SENSe AVERage STATe Parameter 0 Turn the Average function off Turn the Average function on OFF Turn the Average function off ON Turn the Average function on Return parameter 0 The Average function is off The Average function is on Example AVER STAT ON SENSe AVERage TYPE Set Description Sets the method that the Average function uses to calculate the average Syntax SENSe AVERage TYPE VOLTage LOGarithmic POWer 151 GW INSTEK GSP 9300 Programming Manual Query syntax SENSe AVERage TY PE Parameter Return VOLTage Sets Average to voltage parameter LOGarithmic Sets Average to logarithmic POWer Sets Average to power Example AVER TYPE VOLT Set SENSe BAN Dwidth BWIDth RESolution Description Sets or queries the resolution bandwidth RBW Syntax SENSe BAN Dwidth BW1Dth RESolution freq Query Syntax SENSe BAN Dwidth BW1IDth RESolution Parameter lt freq gt lt NRf gt Return parameter lt NR3 gt Hz Example BAND 1 0e 6 SENSe BANDwidth BWIDth Set RESolution AUTO Description Turns the RBW to auto on or manual off or queries its state Syntax SENSe BANDwidth BWIDth RESolution AUTO OFF ON O 1 Query Syntax SENSe BANDwidth
15. 209 SSTATus QUEStionable ACPLimit ENABle 210 SSTATus QUEStionable ACPLimit EV EN t 210 72 GW INSTEK REMOTE CONTROL SSTATus QUEStionable ACPLimit N TRansition 211 SSTATus QUEStionable ACPLimit PTRansition 211 SSTATus QUEStionable SEMLimit CONDition 212 SSTATus QUEStionable SEMLimit ENA Ble 213 SSTATus QUEStionableSEMLimit EVEN 213 SSTATus QUEStionable SEMLimit NTRansition 214 SSTATus QUEStionable SEMLimit PTRansition 215 SSTATus QUEStionable TOILimit CONDition 215 SSTATus QUEStionable TOILimicENA Ble 216 SSTATus QUEStionable TOTLimit 7EVENt 216 SSTATus QUEStionable TOILimit NTRansition 216 SSTATus QUEStionable TOILimit PTRansition 217 STA lus PRES E e nai Edebg 217 TRACe SERACE OA TA 2 ss i 217 commands PIXel TRACe lt n gt TRIGger TRIGger SEQuence DELay eee commands TRIGger SEQuence DEMod DELay TRIGger SEQuence DEMod LEVel UNIT commands TRIGger SEQuence DEMod MODE TRIGger SEQuence DEMod SLOPe TRIGger SEQuence DEMod SOURCE TRIGger SEQuence DEMod TIME STARt TRIGger SEQuencej DEMOod TIME STODP TRIGger SEQuence E
16. AVBRage COU Nt eterne taria AVERage STATe DAV BRage TYPE ettet BANDwidth BWIDth RESolution 152 BANDwidth BWIDth RESolution AUTO 152 BANDwidth BWIDth VIDoeo 153 BANDwidth BWIDth VIDeo AUTO 153 CHANneESPACe DOWN eerte CHANnelSPACe UP eee CNR ICHANnelSPACe eee CNR DELTamarker MODE gt CORRection CSET lt n gt DATA eee cee CORRection CSET lt n gt STAT gt CORRection CSET lt n gt DELete CSO CHANneLESPACe eee CTB CHANneLSPACe eee DEMod EARPhone TYPE DEMod EARPhone VOLaume DEMOd EARPhone GAIN DEMod FILTer LPASs trennen DEMod SQUelch LEVel DETector FUNCtion DETector FUNCton AU TTO EMIFilte STA aiite c c LA LL CC CC CC C C c c 69 GW INSTEK GSP 9300 Programming Manual 70 SENS SENSe P1DB AVERage COUNt sese e P1DB GAIN OFFSet SENSe OCBW BANDwidth BWIDth 65 SENSe OCBW PERGe nt eterne 65 SENSe OCBW SPACe 66 SENSe SEMask BANDwidth BWIDth INTegration170 SENSe SEMask BANDwidth BWIDth RESolu
17. Example PTDB AVER COUN 10 Set SENSe P1 DB GAIN OFFSet Description Sets or queries the gain offset in dB Syntax SENSe PTDB GAIN OFFSet lt rel_ampl gt Query Syntax SENSe P1DB GAIN OFFSet 166 GW INSTEK REMOTE CONTROL Parameter lt rel_ampl gt Return parameter lt NR3 gt Returns the gain offset value in dB Example P1DB AVER COUN 10 00e 00 Set SENSe PMETer FREQuency Description Sets or queries the power meter measurement frequency Syntax SENSe PMETer FREQuency freq Query Syntax SENSe PMETer FREQuency Parameter lt freq gt lt NRf gt Return parameter lt NR3 gt Hz Example PMET FREQ 2e 7 Set SENSe PMETer HLIMit Description Sets or queries the power meter high limit for pass fail tests Syntax SENSe PMETer HLIMit lt ampl gt Query Syntax SENSe PMETer HLI Mit Parameter lt ampl gt lt NRf gt power unit default dBm Return parameter lt NR3 gt Unit current unit Example PMET HLIM 10 Set SENSe PMETer HOLD STATe Description Turns the power meter Max Min Hold function on off or queries its state Syntax SENSe PMETer HOLD STATe OFF ON 0 1 Query Syntax SENSe PMETer HOLD STATe 167 GW INSTEK GSP 9300 Programming Manual Parameter 0 Turn the Max Min Hold function off 1 Turn the Max Min Hold function on OFF Turn the Max Min Hold function off ON Turn the Ma
18. Hz Selectable bandwidth of LPF Hz n n 2 n 3 n 4 n 5 278 125 156 250 78 125 52 083 39 068 31 250 239 063 78 125 39 063 26 042 19 531 15 625 219 531 39 068 19 531 13 021 9 766 7 813 27 813 15 625 7 813 5 208 3 906 3 125 23 906 7 813 3 906 2 604 1 953 1 563 21 953 3 906 1 953 1 302 977 781 2781 1 563 781 521 391 313 2391 781 391 260 195 156 2195 391 195 130 98 78 278 156 78 52 39 31 239 78 39 26 20 16 220 39 20 13 10 8 28 16 8 5 4 9 Example DEM FILT LPAS B Set SENSe DEMod IFBW Description Sets or queries the IF bandwidth for the AM FM Analysis function Syntax SENSe DEMod IFBW freq Query Syntax SENSe DEMod IFBW GW INSTEK REMOTE CONTROL Parameter lt freq gt lt NRf gt Return parameter lt NR3 gt Hz Example DEM IFBW 3 0e 5 Set SENSe DEMod SQUelch LEVel Description Sets or queries the carrier squelch level Syntax SENSe DEMod SQUelch LEVel dBm level gt Query Syntax SENSe DEMod SQUelch LEVel Parameter dBm lt NRf gt Return parameter lt NR3 gt Squelch level in dBm Example DEM SQU LEV 1 30e 2 Set SENSe DETector FUNCtion Description Sets or queries the trace detection mode when in manual mode Syntax SENSe DETector FUNCtion AVERage SAMPle POSitive NEGative NORMal Query Syntax SENSe DETector FUNCtion Parameter AVERage
19. MARKer lt n gt FCOunt RESolution 97 CALCulate MARKercn FCOunt RESolution AUTO m r M 98 CALCulate MARKercn FCOuntSTATe 98 CALCulate MARKercn FCOuntX ees 99 CALCulate MARKercn2 NOISe STATe CALCulate MARKercn2 NOISe Y ess 00 CALCulate MARKercn PEAK eee 00 CALCulate MARKer PEAK CTRack STATe we LOO CALCulate MARKer PEAK DATA eee 01 CALCulate MARKer PEAK EX Cursion ww 101 CALCulate eMARKer PEAK SORT TYDE 02 CALCulate MARKer PEAK TABLe STATe 02 CALCulate MARKer PEAK THReshold 02 CALCulate MARKer PEAK THReshold STATe 103 CALCulate MARKern SET eene CALCulate MARKercn STA Te CALCulate MARKer TABLe STATe CALCulate MARKercn2 TRACe CALCulate MARKercn2 TRACe AUTO 05 78 GW INSTEK REMOTE CONTROL CALCulate MARKer lt n gt TYPB eee 105 CALCulate MARKern X eese CALCulate MARKercn Y GALGulate MA TH LDI F cese eseeseet cese CALCulate MATH LOFF CALCulate NDB STATe eene CALCulate NDB BAND width BWIDth 108 CALCulate NORMalize STATe CALCulate OCBW STATe
20. STATus QUEStionable FREQuency EVENt Return parameter Bit Bit Weight Description 5 32 Invalid Span BW Example STAT QUES FREQ gt 32 STATus QUEStionable FREQuency Set NTRansition Description Sets or queries the bit weight of the NTR filter for the Questionable Status Frequency register 208 GW INSTEK REMOTE CONTROL Syntax STATus QUEStionable FREQuency NTRansition lt integer gt Query Syntax STATus QUEStionable FREQuency NTRansition Return parameter Bit Bit Weight Description 5 32 Invalid Span BW Example STAT QUES FREQ NTR 32 STATus QUEStionable F REQuency Set PTRansition Description Sets or queries the bit weight of the PTR filter for the Questionable Status Frequency register Syntax STATus QUEStionable FREQuency PTRansition lt integer gt Query Syntax STATus QUEStionable FREQuency PTRansition Return parameter Bit Bit Weight Description 5 32 Invalid Span BW Example STAT QUES FREQ PTR 32 STATus QUEStionable ACPLimit CONDition Description Returns the bit weight of the Questionable Status ACP Limit Condition register Query Syntax STATus QUEStionable ACPLimit CONDition 209 GW INSTEK GSP 9300 Programming Manual Return parameter Bit Bit Weight Description 0 Main channel high fail 1 2 Main channel low fail 2 4 Adj1 high fail 3 Adj1 low fail 4 16 Adj2 high fail 5 32 Adj2 low fail 6 64 Adj3 high f
21. this bit is set to 1 Power On When the instrument is turned off gt on this bit is set to 1 GW INSTEK REMOTE CONTROL Operation Status Register Overview The Operation Status Register Group indicates the operating status of the GSP 9300 Bit Summary Bit Weight Description 3 8 Sweeping Indicates that a sweep is in progress 4 16 Measuring The instrument is currently performing a measurement 5 32 Waiting for Trigger The instrument is in a wait for trigger state Questionable Status Register Overview The Questionable Status Register Group indicates if any limits have been tripped Bit Summary Bit Weight Description 5 32 Frequency Status Summary Bit This is the summary bit of the Frequency Status Register 8 256 Uncal This bit is set when a signal level occurs because the sweep is too fast 9 512 Limit fail This bit is set to 1 when the limit line has been violated 10 1024 ACP Limit Status Summary Bit This is the summary bit for the ACP Limit Status Register 1 2048 SEM Limit Status Summary Bit This is the summary bit for the SEM Limit Status Register 12 4096 TOILimit Status Summary Bit This is the summary bit for the TOI Limit Status Register 13 8192 Pmet Limit Fail This bit is set to 1 when the power meter limit has been violated GW INSTEK GSP 9300 Programming Manual 14 16384 2FSK Fail This bit is set to 1 when the 2FSK fail conditions are met 15 32768 Demod Fail
22. 123 DISPlay WINDow SPLit TOPO ees 123 8 124 DISPlayWINDow TOPO MARK PERCent 124 DISPlay WINDow TOPO DELT PERCent 124 DISPlay WINDow TRACecn MODRE 125 DISPlay WINDow TRACE lt n gt MODE MAKXHOLD riria anr E 125 DISPlay WINDow TRACe Y DLINe 125 DISPlay WINDow TRACe Y DLINe STATe 126 DISPlay WINDow TRACe Y SCALe AUTO 126 DISPlay WINDow TRACe Y SCALe NRLevel 126 DISPlayWINDow TRACe Y SCALe NRPosition 127 DISPlay WINDow TRACe Y SCALe PDIVision 127 DISPlay WINDow TRACe Y SCALe POSition 128 DISPlay WINDow TRACe Y SCALe RLEVel 128 DISPlay WINDow TRACe Y SCALe RLEVel 117 GW INSTEK GSP 9300 Programming Manual DISPlay WINDow TRACe Y SCALe SPACing 129 DISPlay WINDow TRACe Y SCALe STATe 129 DISPlay SPECtrogram DELTA INVerse TIME 130 Set DISPlay BRIGhtness Description Sets or queries the LCD brightness level Syntax DISPlay BRIGhtness HIGH MIDDle LOW Query Syntax DISPlay BRIGhtness Parameter HIGH High brightness level Return parameter lt MIDDle gt Mid brightness level lt LOW gt Low brightness level Example DISP BRIG HIGH Set DISPlay ENABle Description Turns the LCD backlight on off Syn
23. 33e 01 CALCulate OCBW PSD Query Description Returns the OCBW power spectral density Query Syntax CALCulate OCBW PSD Return parameter lt NR3 gt PSD in dBm Hz Example CALC OCBW PSD gt 9 933e 01 Set CALCulate P1 DB STATe Description Turns the P1DB function on or off Syntax CALCulate P1DB STATe ON OFF 1 O Query Syntax CALCulate P1 DB STATe Parameter OFF 0 Turns limits off ON 1 Turns limits on Return parameter 0 Turns limits off 1 Turns limits on Example CALC PTDB STAT 20 GW INSTEK REMOTE CONTROL CALCulate P1 DB GAIN AVERage Description Returns the P1dB average gain Query Syntax CALCulate P1 DB GAIN AVERage Return parameter lt NR3 gt Return the average gain in dB N A Returns N A if the P1dB value is not found or not applicable Example CALC P1DB GAIN AVER gt 1 416e 01 CALCulate P1 DB GAIN RESult Description Returns the gain in dB for each 1dBm increase in TG input level from 30dBm to 0dBm Query Syntax CALCulate PTDB GAIN RESult Return parameter NR3 NR3 NR3 31 return values lt NR3 gt Gain in dB Starting at 30dBm and ending at OdBm Example CALC PTDB GAIN RES gt 0 00e 00 0 00e 00 0 00e 00 0 00e 00 0 00e 00 0 00 e 00 0 00e 00 0 00e 00 0 00e 00 0 00e 00 0 00e 00 0 00e 00 0 00e 00 0 00e 00 0 00e 00 0 00e 00 0 00e 00 0 00e 00 0 00e 00 0 00e 00 1 382e 01 1 406e 01 1 401e 01 1 40
24. 508 Example pixeHt pixel value 162 Pixel data in image a e Pixel value Pixel number 1 601 Pixel 1 Pixel 601 218 GW INSTEK REMOTE CONTROL Query Syntax PIXel TRACe lt n gt Parameter lt n gt NRI trace 1 4 Return Parameter pixel data Pixel data Returned as ASCII code in binary coded decimal format pixel HbyteLbyte pixel2 HbyteLbyte pixel3 HbyteLbyte and so on until the EOF character Example PIXEL TRACE gt gt H x16 xA8 x16 xA8I fl xD4 x1 Ex x1 E xDCF xB4F xB 4 x80 xE4C xF8E x04 hB xCCCO x18 xB4D xCOE xEC2d2dD xCOE xEC5 xE85 EOF For example data for the first pixel is returned as dH the second as x the third as 16 and so on Using the first pixel data as an example the high byte is and the low byte as H To convert this data into a pixel value follow the steps below Binary coded decimal notation in ASCII High byte low byte High byte low byte converted into binary 00111 01001 111 000 0011111101001000 Convert binary into decimal Combine high byte amp low byte Divide the pixel data by 100 to get the pixel value 219 GW INSTEK GSP 9300 Programming Manual TRIGger Commands 5 220 TRIGger SEQuence DEMod DELay 220 TRIGger SEQue
25. BWIDth RESolution AUTO Parameter 0 Turn RBW to manual off Turn RBW to automatic on OFF Turn RBW to manual off ON Turn RBW to automatic on Return parameter 0 RBW is set to manual off 1 RBW is set to automatic on Example BAND AUTO ON 152 GW INSTEK REMOTE CONTROL Set SENSe BAN Dwidth BWIDth VIDeo Description Sets or queries the video bandwidth VBW Syntax SENSe BAN Dwidth BWIDth VIDeo freq Query Syntax SENSe BAN Dwidth BW1Dth V IDeo Parameter lt freq gt lt NRf gt Return parameter lt NR3 gt Hz Example BAND VID 1 0e 6 Set SENSe BAN Dwidth BWIDth VIDeo AUTO Description Turns the VBW to auto on or manual off or queries its state Syntax SENSe BAN Dwidth BW1Dth VIDeo AUTO OFF ON O 1 Query Syntax SENSe BAN Dwidth BWIDth VIDeo AUTO Parameter 0 Turn VBW to manual off 1 Turn VBW to automatic on OFF Turn VBW to manual off ON Turn VBW to automatic on Return parameter 0 VBW is set to manual off 1 VBW is set to automatic on Example BAND VID AUTO OFF SENSe CHANnel SPACe DOWN Set Description Moves to the previous main channel when using measurements that have a channel space setting Syntax SENSe CHANnel SPACe DOWN Example CHAN SPAC DOWN 153 GW INSTEK GSP 9300 Programming Manual SENSe CHANnel SPACe UP Set Description Moves to the next main channel when usin
26. CTB RESult CALCulate CTB STATe n CALCulate CTB RESTart eeeeeeete CALCulate DELTamarker lt n gt PAIR SPAN CALCulate DELTamarker lt n gt PAIR CENTet CALCulate DELTamarker lt n gt X sess CALCulate DELTamarker lt n gt Y us CALCulate DEMod AM RESult CURRent CALCulate DEMod AM RESult MINimum CALCulate DEMod AM RESult MA Ximum 88 GW INSTEK REMOTE CONTROL CALCulates DEMod AM STAT eee 88 CALCulate DEMOQG EARPhone STATe 89 CALCulate DEMOd FEM RESult CURRent 89 CALCulate DEMOod FM RESultMINimum 90 CALCulate DEMOod FM RESult M A Ximut 90 CALCulate DEMOG FM STATe eee CALCulate DEMOG RESet eee CALCulate t HARMonic DISTortion CALCulate HARMonic R ESult eee 92 CALCulate HARMonic STATe eee 92 CAL Culate EE Tee S T ATe uci taie 92 CALCulate ITTer CARRier POWere eee 93 CALCulate JITTer PHASe oo CAL Culate TT Tet TIME cast 93 94 5 94 3 5 94
27. Description Turns the Sweep time setting to auto on or manual off Syntax SENSe SWEep TIME AUTO OFF ON O 1 Query Syntax SENSe SWEep TIME AUTO Parameter 0 Turn sweep time to manual off 1 Turn sweep time to auto on OFF Turn sweep time to manual off ON Turn sweep time to auto on Return parameter 0 Sweep time is set to manual 1 Sweep time is set to automatic Example SWE TIME AUTO 0 Set SENSeJ TOI REFerence Description Sets or queries the TOI reference to the upper or lower base Syntax SENSe TOI REFerence UPPer LOWer 189 GW INSTEK GSP 9300 Programming Manual Query Syntax SENSe TOI REFerence Parameter UPPer Upper base Return parameter LOWer Lower base Example TOI REF UPP Set SENSe TOI LIMit Que Description Sets the TOI pass fail limit amplitude Syntax SENSe TOL LIMit lt ampl gt Query Syntax SENSe TOI LIMit Parameter lt ampl gt lt NRf gt Power or voltage Return parameter lt NR3 gt Example TOI LIM 30 190 GW INSTEK REMOTE CONTROL SOURce Commands SOURce POWer LE Vel MMediate AMPLitude 191 SOURce POWer LE Vel MMediate AMPLitude SOURce POWer LEVel IM Mediate Set AMPLitude Description Sets or queries the tracking generator power level Syntax SOURce POWer LEVel IMMediate AMPLitude lt ampl gt Query Syntax SOURce POWer LEVel IM Mediate AMPLitude Parameter l
28. MMEMory STORe SCReen new dest file name Parameter new dest file name Example MMEM STOR SCR test jpg MMEMory STORe SEQuence Set Description Store sequence data to a file from the internal memory Syntax MMEMory STORe SEQuence seq num new dest file name Parameter seq num lt NR1 gt sequence number 1 5 new dest file name 56 Example MMEM STOR SEQ 2 test seq MMEMory STORe STATe Set Description Store the instrument state to a file from the internal memory Syntax MMEMory STORe STATe new dest file name GW INSTEK REMOTE CONTROL Parameter lt new_dest_file_name gt XXX stat Example MMEM STORe STAT test stat MMEMory STORe TRACe Set Description Store trace data to a file from the internal memory Syntax MMEMory STORe TRACe trace name gt new dest file name Parameter trace name gt NRI 1 4 new dest file name XXX tra Example MMEM STORe TRAC 2 test tra 141 GW INSTEK GSP 9300 Programming Manual OUTPut Commands TOU EP wt STA Ee 142 Set OUTPUut STATe Description Turns the tracking generator output on off or queries its state Syntax OUTPut STATe 1 Query Syntax OUTPut STATe Parameter 0 Turn TG output off 1 Turn TG output on OFF Turn TG output off ON Turn TG output on Return parameter 0 TG output is off TG output is on Example OUTP ON 14
29. RBW Bands 3 5 lt B lt 12 5 15dBm Unit MHz AdditionalBl RBW Band V 2 5 A 3 5 15dBm 30kHz 3 5 lt B lt 12 5 13dBm 100kHz Unit MHz AdditionalBl RBW Bands 3 5 lt B lt 12 5 13dBm 100kHz Parameter lt n gt Offset 1 to 5 Return parameter lt NR3 gt RBW in Hz Example SEM OFFS1 ADD BAND gt 3 000000000e 04 175 GW INSTEK GSP 9300 Programming Manual SENSe SEMask OFFSet lt n gt ADDition FREQuency STARt Query Description Returns the start frequency refered to the center of the selected offset for the additional requirements of the selected 3GPP SEM test Query syntax SENSe SEMask OFFSet lt n gt ADDition FREQuency STARt Parameter lt n gt Offset 1 to 5 Return parameter lt NR3 gt Start frequency in Hz Example SEM OFFST ADD FREQ STAR gt 2 5e 6 SENSe SEMask OFFSet lt n gt ADDition FREQuency STOP Query Description Returns the stop frequency refered to the center of the selected offset for the additional requirements of the selected 3GPP SEM test Query syntax SENSe SEMask OFFSet lt n gt ADDition FREQuency STOP Parameter lt n gt Offset 1 to 5 Return parameter lt NR3 gt Stop frequency in Hz Example SEM OFFST ADD FREQ STOP gt 3 5e 6 GW INSTEK REMOTE CONTROL SENSe SEMask OFFSet lt n gt ADDition STARt ABSolute Description Returns the start amplitude dBm of the Absolute Mask for the selected offset for t
30. SMB port 10 GW INSTEK GETTING STARTED Accessories Standard Accessories Options Optional Accessories Part number Region dependant Region dependant N A N A N A Option number Optl Opt2 Opt3 Part number GSC 009 PWS 06 GRA 415 Software Downloads Description User manual Power cord Certificate of calibration Quick Start Manual User Manual CD Description Tracking generator Battery 11 1V 5200mAH Li ion battery GPIB interface IEEE 488 bus Description Soft Carrying Case USB Average Power Sensor up to 6200 MHz 32 to 20 dBm 6U Rack mount kit PC Software for Windows System IVI Driver Supports LabView amp LabWindows CVI Programming Android System GSP 9300 Remote Control available on Google Play GW INSTEK GSP 9300 Programming Manual Appearance GSP 9300 Front Panel LCD Function Main Control File keys display keys keys keys Power key T eem em Hd Marker keys Preset Local 70 hE and Quick Auxillary keys Save keys f N Scroll wheel 2A 6 Arrow keys J i tl Y 5 6 RF input j TEANA terminal E USB A Tracki
31. Set Description Sets the operation mode of the selected trace Syntax DISPlay WINDow TRACe lt n gt MODE WRITe VIEW BLANk MAXHold MINHold Parameter lt n gt NRI Trace number 1 4 WRITe Clear and Write VIEW Hold the last trace BLANK Clears the trace MAXHold Hold the maximum minimum points MINHold from each sweep Example DISP TRAC4 MODE VIEW DISPlay WINDow TRACE lt n gt MODE MAX HOLD Description Returns the maxhold threshold level Any part of the trace below this threshold won t be held when the detector is set to Maxhold Query syntax DISPlay WINDow TRACE lt n gt MODE MAXHOLD Return parameter lt n gt lt NR1 gt Trace number lt NR3 gt Example DISP TRACE2 MODE MAXHOLD gt 2 000e 01 Set DISPlay WINDow TRACe Y DLINe Description Sets or queries the display line amplitude level Syntax DISPlay WINDow TRACe Y DLINe lt ampl gt Query Syntax DISPlay WINDow TRACe Y DLINe 125 GW INSTEK GSP 9300 Programming Manual Parameter lt ampl gt lt NRf gt Power or voltage in the current Y axis unit Return parameter lt NR3 gt Example DISP TRAC Y DLIN 5 0e 01 Set DISPlay WINDow TRACe Y DLINe STATe Description Turns the display line on off or queries its state Syntax DISPlay WIN Dow TRACe Y DLINe STATe OFF ON O 1 Query Syntax DISPlay WINDow TRACe Y DLINe STATe Parameter 0 Turn display line off 1 Turn displ
32. Sets the detector mode to Average Return parameter SAMPle Sets the detector mode to Sample POSitive Sets the detector mode to Peak NEGative Sets the detector mode to Peak NORMal Sets the detector mode to Normal Example DET NORM Set SENSe DETector FUNCtion AUTO Description Turns the trace detection mode to auto on or manual off or queries its state Syntax SENSe DETector FUNCtion AUTO 1 159 GW INSTEK GSP 9300 Programming Manual Query Syntax SENSe DETector FUNCtion AUTO Parameter 0 Turn the detection mode to manual off 1 Turn the detection mode to auto on OFF Turn the detection mode to manual off ON Turn the detection mode to auto on Return parameter 0 The detection mode is set to manual 1 The detection mode is set to automatic Example DET AUTO ON Set SENSe EMIFilter STATe Description Turns the EMI filter on off or queries its state Syntax SENSe EMIFilter STATe OFF ON 0 1 Query Syntax SENSe EMIFilter STATe Parameter 0 Turn the EMI filter off Turn the EMI filter on OFF Turn the EMI filter off ON Turn the EMI filter on Return parameter 0 The EMI filter is off The EMI filter is on Example EMESTAT 0 SENSe EMIFilter BAN Dwidth BW1Dth RESolution Set Description Sets the EMI filter bandwidth must be set to the exact bandwidth Syntax SENSe EMI Filter BAN Dwidth BW1Dth RESolution lt freq g
33. be grayed out to indicate that it is connected but not activated 3G USB Adapter Settings 1 Insert the 3G USB modem into the front panel USB A port and wait for the 3G USB icon to appear 2 Press sem gt More F 7 gt RmtInterface F1 gt LAN F2 gt WLAN Config F2 gt Apply F6 and wait for the 3G USB modem to establish the WLAN settings Finish is shown when the configuration is complete 3 The network settings will be displayed in the System menu icons 31 GW INSTEK GSP 9300 Programming Manual WLAN settings Display Icon The 3G USB icon turns green when a successful connection has been made Set Password The password on the LXI webpage can be set from the spectrum analyzer The password is shown in the system information By default the password is set to kiWNpwd 4 Press gt More F7 gt RmtInterface Config F1 gt LAN F2 gt LXIPassword F3 to set the password 5 Enter the password using the F1 F7 keys as shown below or use the numeric keypad to enter numbers Limitations e No spaces Only 1 9 a z characters allowed 32 GW INSTEK REMOTE CONTROL di A B 8 rr 4 4 ABCDE H D b 4 4 FGHIJ E 4 4 4 KLMNO Lowercase d 4 Rename gt PQRST Return e Q J UVWXY Return M Return j Y Cancel password Menu tree to enter the passwo
34. becomes the active window This command will also put the screen into split screen mode if it is not already Syntax DISPlay WINDow SPLit NORMal ACTive UPPer LOWer Example DISP SPL NORM ACT UPP DISPlay WINDow SPLit SPECtrogram Set Description Sets the split screen mode to Spectrogram Spectrum Syntax DISPlay WINDow SPLit SPECtrogram Example DISP SPL SPEC DISPlay WINDow SPLit TOPO Set Description Sets the split screen mode to Topographic Spectrum 123 GW INSTEK GSP 9300 Programming Manual Syntax DISPlay WIN Dow SPLit TOPO Example DISP SPL TOPO DISPlay WINDow TOPO Set Description Sets the display window to topographic Syntax DISPlay WIN Dow TOPO Example DISP TOPO DISPlay WINDow TOPO MARK PERCent Description Returns the percentage of traces that cross the reference marker position in the topographic display view Query syntax DISPlay WINDow TOPO MARK PERCent Return parameter lt NR3 gt Example DISP TOPO MARK PERC gt 0 000e 00 DISPlay WIN Dow TOPO DELT PERCent Description Returns the percentage of traces that cross the delta marker position in the topographic display view Query syntax DISPlay WINDow TOPO DELT PERCent Return parameter lt NR3 gt Example DISP TOPO DELT PERC gt 6 667e 01 124 GW INSTEK REMOTE CONTROL DISPlay WINDow TRACe lt n gt MODE
35. bit is set to 1 when the 3rd Order Lower limit has been tripped Questionable Status Demod Fail Register Overview The Questionable Status Demod Fail Register Group indicates if pass fail limit has been tripped for either AM or FM analysis Bit Summary Bit Weight Description 1 AM Fail This bit is set to 1 when the limit has been tripped for AM depth carrier offset or carrier power 1 2 FM Fail This bit is set to 1 when the limit has been tripped for FM frequency deviation carrier offset or carrier power GW INSTEK GSP 9300 Programming Manual Command List SCPI Commands 74 CALCulate CALCulate ACPR ACHannel lt n gt HLIMit FAIL 79 Commands CALCulate ACPR ACHannel lt n gt LLIMit FAIL 80 CALCulate ACPR ACHannelcn LOWetr 80 CALCulate ACPR ACHannel n2 UPPetr 80 CALCulate ACPR ACHannel lt n gt STATe CALCulate ACPR CHANnel HLIMit FAIL CALCulate ACPR CHANnel LLIMit FAIL CALCulate ACPR CHPowet eee CALCulate ACPR STATe CALCulate BESK STATe CALCulate BFSK RESTart CALCulate BESK RESult CALCulate CNR RESult CALCulate CNR STATE CALCulate CSO RESult CALCulate CSO STA Te CALCulate
36. e Input impedance 500 Maximum DC voltage t50V e N type female 15 GW INSTEK GSP 9300 Programming Manual DC power supply SMB port supplies power for OC optional accessories 500mA MAX A Surur e DC 7V e 500mA Max The numeric keypad is used to enter values and parameters It is often used in conjunction with the arrow keys and scroll wheel Numeric keypad OOOO 2 6000 The Tracking Generator TG TG output port Output source TG OUTPUT 500 N type female f DC 50V MAX Pee EWE ET c Input impedance 500 e Output power 50dBm to 0dBm e Maximum reversed power 30dBm USB A MicroSD 28 USB A port Micro SD port for gt saving recalling settings files 16 GW INSTEK GETTING STARTED Rear Panel IF OUT DVI I USB B an Power port LAN port socket RS232 port TRIG IN
37. eese CALCulate OCBW BAND width BWIDth CALCulate OCBW CHbPowet eee CALCulate OCBW POWer eee tnt 110 CALCulate OCBW PSD eese 110 CALCulate P1 DB STATe CALCulate P1 DB GAIN AVERage 111 CALCulate P1 DB GAIN RESult eese 111 CALCulate P1 DB RESult CALCu CALCulate PMETer LIMICSTATe eee CALCulate PMETer LIMitFAIL CALCulate SEM STATe eee CALCulate sSEM OFFSetcn RESult 113 CALCulate TOI DIFFerential CALCulate TOI FEREQuency DIFFerential 114 GCATLCulate EOD LIMItICS LA Te ette CALCulate TOL RESult CALCulate TOI STATe CALCulate ACPR ACHannel lt n gt HLIMit FAIL Description Returns the ACPR upper limit pass fail judgment for the selected adjacent channel Query Syntax CALCulate ACPR ACHannel lt n gt HLIMit FAIL Parameter lt n gt lt NR1 gt adjacent channel 1 3 Return parameter 0 lt boolean gt Pass 1 lt boolean gt Fail 79 GW INSTEK GSP 9300 Programming Manual Query Example CALC ACPR ACH1 HLIM FAIL gt 0 CALCulate ACPR ACHannel lt n gt LLIMit FAIL Query Description Returns the ACPR lower limit pass fail judgment for the selected adjacent channel Query Syntax CALCulate ACPR ACHannel lt n gt LLIMit FAIL
38. ien et ete tt ns 133 INPut OFFSet eee e eese sese tse enti tsta htt atas sina dae 133 MMEMory MMEMory CATalog eerta 134 commands MMEMory CDIRectoty n MMEM OY COPY pieta tci iH RH MMEMory DESTination s MMEMory LOAD CORRection eee 37 37 MMEMory LOAD PMETet ia 137 MMEMory LOAD SEQuence an sa 137 MMEMory LOAD STATe E 138 MMEMory LOAD TRACe 138 MMEMory MOVE an 138 MMEMory REName eee 139 MMEMory STORe CORRection 439 242129 MMEMory STORe PMETet sis a 140 MMEMory STORe SCReen sis 140 MMEMory STORe SEQuence ee w 140 MMEMory STORe STATe 140 5 41 OUTPut HOW TPut S EA Fe onec cencstecshatstenastaspsazatedssy pires 42 commands SENse SENSe ACPR ACHannel n commands BANDwidth reset tote teen SENSe ACPR ACHannel n HLIMit SENSe ACPR ACHannel n LLIMit SENSe ACPR ACHannel lt n gt OFFSet oe SENSe ACPR BANDwidth BWIDth SENSe ACPR HLIMit SENSe ACPR LLIMit SENSe ACPRiHELP STAT csssscsscsesse
39. if any of the SEM offset limits have been tripped Bit Summary Bit Weight Description 0 1 Offset 1 Upper Fail This bit is set to 1 when the SEM Offset 1 upper limit has been violated 1 2 Offset 1 Lower Fail This bit is set to 1 when the SEM Offset 1 lower limit has been violated 2 4 Offset 2 Upper Fail This bit is set to 1 when the SEM Offset 2 upper limit has been violated 3 8 Offset 2 Lower Fail This bit is set to 1 when the SEM Offset 2 lower limit has been violated 4 16 Offset 3 Upper Fail This bit is set to 1 when the SEM Offset 3 upper limit has been violated 5 32 Offset 3 Lower Fail This bit is set to 1 when the SEM Offset 3 lower limit has been violated 6 64 Offset 4 Upper Fail This bit is set to 1 when the SEM Offset 4 upper limit has been violated 7 128 Offset 4 Lower Fail This bit is set to 1 when the SEM Offset 4 lower limit has been violated 8 256 Offset 5 Upper Fail This bit is set to 1 when the SEM Offset 5 upper limit has been violated 9 512 Offset 5 Lower Fail This bit is set to 1 when the SEM Offset 5 lower limit has been violated GW INSTEK REMOTE CONTROL Questionable Status TOI Limit Register Overview The Questionable Status TOI Limit Register Group indicates if the 3rd Order Upper or Lower limit has been tripped Bit Summary Bit Weight Description 0 1 3rd Upper Fail This bit is set to 1 when the 3rd Order Upper limit has been tripped 1 2 3rd Lower Fail This
40. integer 300 600 1 200 2400 4800 9600 19200 38400 57600 115200 Example SYST COMM SER BAUD 9600 SYSTem COMMunicate USB MODE Set Description Configures the USB mode Syntax SYSTem COMMunicate USB MODE HOST DEVice Parameter HOST USB host mode Return parameter DEVice USB device mode Example SYST COMM USB MODE DEV Set SYSTem DATE Description Sets the system date Syntax SYSTem DATE lt year gt lt month gt lt day gt 197 GW INSTEK GSP 9300 Programming Manual Query Syntax SYSTem DATE Parameter lt year gt NRI Return parameter month NRI day NRI Example SYST DATE 2011 03 27 SYSTem ERRor CLEar Set Description Clears the error messages from the error queue Syntax SYSTem ERRor CLEar SYSTem ERRor NEXT Query Description Returns the next message from the error queue Reading the error from the error queue will clear that error from the queue Syntax SYST ERR SYSTem KLOCk Set Description Locks unlocks the front panel keys Syntax SYSTem KLOCk ON OFF Parameter ON Lock the front panel keys OFF Unlock the front panel keys Example SSYST KLOCK OFF SYSTem PRESet Set Description Returns the GSP 9300 to preset settings Syntax SYST PRES 198 GW INSTEK REMOTE CONTROL Set SYSTem PRESet TYPE Description Sets the preset type between user defined and factory default Syntax SYSTem PRESet TY
41. is on Example CALC MARK TABL STAT ON Set CALCulate MARKer lt n gt TRACe Description Assigns the selected marker to a trace Queries which trace the selected marker is assigned to Syntax CALCulate MARKer n TRACe trace name gt 104 GW INSTEK REMOTE CONTROL Query Syntax CALCulate MARKer lt n gt TRACe Parameter lt n gt lt NR1 gt Marker number 1 6 Return parameter lt trace The name of the trace 1 2 3 4 name Example CALC MARK2 TRAC 1 Set CALCulate MARKer lt n gt TRACe AUTO Description Sets or queries the state of the Marker Trace function Allows the selected marker to be automatically assigned to a trace on or be to manually assigned a trace off Syntax CALCulate MARKer lt n gt TRACe AUTO ON OFF 1 0 Query Syntax CALCulate MARKer lt n gt TRACe AUTO Parameter lt n gt Marker number 1 6 0 Turn the auto function off 1 Turn the auto function on OFF Turn the auto function off ON Turn the auto function on Return parameter 0 The auto function is off 1 The auto function is on Example CALC MARK2 TRAC AUTO OFF Set CALCulate MARKer lt n gt TY PE Description Sets or queries the marker type Syntax CALCulate MARKer lt n gt TYPE NORMal DELTa Query Syntax CALCulate MARKer lt n gt TY PE Parameter lt n gt lt NR1 gt Marker number 1 6 Return parameter lt NORMal gt Normal marker lt DELTa gt Delta marker Exampl
42. limit line is used for the high limit Syntax CALCulate LIMit HIGH limit num Parameter limit NRI 1 5 num Example CALC LIM HIGH 2 CALCulate LIMit lt n gt MARKer Set Description Sets the current marker position to a point on a limit line The vertical position of the point is the marker s vertical position a user defined offset Syntax CALCulate LIMit lt n gt MARKer lt point gt lt offset gt Parameter lt point gt NRI point 1 10 offset NR3 dB n Seleted limit line Example CALC LIM1 MARK 5 20 GW INSTEK GSP 9300 Programming Manual Set CALCulate LIMit MODE Description Sets or queries the Pass Fail mode for limit line testing Syntax CALCulate LIMit MODE SING CONT Query Syntax CALCulate LIMit MODE Parameter SING Stops triggering after a pass fail result CONT Continues triggering after a pass fail result Return Parameter SINGLE Stops triggering after a pass fail result CONTINUE Continues triggering after a pass fail result Example CALC LIM MODE CONT Set CALCulate LIMit STATe Description Turns the limit line Pass Fail test on off Syntax CALCulate LIMit STATe ON OFF 1 0 Query Syntax CALCulate LIMit STATe Parameter 0 Pass Fail test is off 1 Pass Fail test is on OFF Pass Fail test is off ON Pass Fail test is on Return parameter 0 Pass Fail test is off 1 Pass Fail test is on Example CALC LIM S
43. lt n gt BAN Dwidth BWIDth RESolution AUTO OFF ON 0 1 Query Syntax SENSe SEMask OFFSet lt n gt BAN Dwidth BWIDth RESolution AUTO Parameter 0 Set RBW to manual 1 Set RBW to auto OFF Set RBW to manual ON Set RBW to auto Return parameter 0 RBW is set to manual 1 RBW is set to auto SENSe SEMask OFFSet lt n gt FREQuency Set STARt Description Sets or queries the start frequency of the selected offset Syntax SENSe SEMask OFFSet lt n gt FREQuency STARt lt freq gt Query Syntax SENSe SEMask OF FSet lt n gt FREQuency STARt 178 GW INSTEK REMOTE CONTROL Parameter lt freq gt lt NR3 gt Hz Return parameter lt n gt lt NR1 gt offset 1 5 Example SEM OFFS1 FREQ STAR 2 5e 3 SENSe SEMask OFFSet lt n gt FREQuency Set STOP Description Sets or queries the stop frequency of the selected offset Syntax SENSe SEMask OFFSet lt n gt FREQuency STOP lt freq gt Query Syntax SENSe SEMask OFFSet lt n gt FREQuency STOP Parameter lt freq gt lt NR3 gt Hz Return parameter lt n gt lt NR1 gt offset 1 5 Example SEM OFFS1 FREQ STOP 2 5e 3 SENSe SEMask OFFSet lt n gt STARt Set ABSolute Description Sets or queries the amplitude of the start frequency of the Absolute Mask for the selected offset Syntax SENSe SEMask OFFSet lt n gt STARt ABSolute lt ampl gt Query Syntax SENSe SEMask OFFSet lt n gt STAR
44. on the same command line Compound commands are separated with either a semi colon or a semi colon and a colon A semi colon is used to join two related commands with the caveat that the last command must begin at the last node of the first command A semi colon and colon are used to combine two commands from different nodes Example calc ctb stat on result 50 GW INSTEK REMOTE CONTROL Command Forms Commands and queries have two different forms long and short The command syntax is written with the short form of the command in capitals and the remainder long form in lower case The commands can be written in capitals or lower case just so long as the short or long forms are complete An incomplete command will not be recognized Below are examples of correctly written commands Long CALCulate ACPR STATe form calculate acpr state CALCULATE ACPR STATE Short CALC ACPR STAT form calc acpr stat Square Brackets Commands that contain square brackets indicate that the contents are optional The function of the command is the same with or without the square bracketed items as shown below Both OUTPut STATe and OUTPut are both valid forms Command MMEMory LOAD CORRection 2 filename cor Format 1 2 34 5 1 Commandheader 4 Comma no space 2 Space before after comma 3 Parameter 1 5 Parameter2 51 GW INSTEK GSP 9300 Programming Manual
45. power in the current Y axis units offset Carrier frequency offset in Hz sinad Signal to noise and distortion ratio in dB Query Example CALC DEM AM RES MAX gt 9 840e 1 1 02e 2 1 12e 1 3 21e 1 1 61e 1 Set CALCulate DEMod AM STATe Description Sets or queries the state of the AM Analysis function GW INSTEK REMOTE CONTROL Syntax CALCulate DEMod AM STATe ON OFF 1 0 Query Syntax CALCulate DEMod AM STATe Parameter 0 Turn AM Analysis off Turn AM Analysis on OFF Turn AM Analysis off ON Turn AM Analysis on Return parameter 0 AM Analysis is off AM Analysis is on Example CALC DEM AM STAT 1 Set CALCulate DEMod EARPhone STATe Description Sets or queries the state of the ear phone out port Syntax CALCulate DEMod EARPhone STATe ON OFF 1 0 Query Syntax CALCulate DEMod EARPhone STATe Parameter 0 Turn the phone output off Turn the phone output on OFF Turn the phone output off ON Turn the phone output on Return parameter 0 Phone output is off 1 Phone output is on Example CALC DEM EARP STAT 1 CALCulate DEMod FM RESult CURRent Description Returns the current measurement results for FM demodulation as a comma separated string Query Syntax CALCulate DEMod FM RESult CURRent Return parameter deviation rate power offset sinad deviation Frequency deviation in Hz rate Modulation rate in Hz power Carrier power in the curr
46. range DANL 30dBm frequency dependent e Input attenuation 0 50dB 1dB steps e Phase noise lt 88dBc Hz 1GHz 10kHz typical Features e 1 3 10 step increments for RBW bandwidth e Three display modes Spectrum Topographic and Spectrographic e Split window display e Built in EMI filter e Auto Wake up e Built in preamplifier GW INSTEK GETTING STARTED Gate sweep e Marker Frequency counter e Two operating modes Spectrum and Power Meter mode e EMI Pretest functions SEM measurement ACPR measurement e OCBW measurement e 2FSK measurement e Phase jitter measurement e Harmonics measurement P1dB measurement e Channel power measurement e Demodulation analyzer e Diverse marker functions and features with Peak Table e Sequence function to automatically perform pre programmed sequential operations e Optional battery operation GW INSTEK GSP 9300 Programming Manual Interface e 8 4 color LCD 800x600 e On screen menu icons DVI I video output e RS 232 with RTS CTS hardware flow control e USB 2 0 with support for USB TMC e LAN TCP IP with LXI support Optional GPIB IEEEA88 interface e Optional 3G USB adapter for WLAN e Optional power meter adapter IF output 9 886MHz e Headphone output e REF reference clock input output BNC ports Alarm Open collector output BNC port Trigger Gate input BNC ports e RF N type input port e Tracking generator output e DC 7V 500mA output
47. scale is logarithmic Syntax DISPlay WINDow TRACe Y SCALe PDIVision 1 2 5 10 Query Syntax DISPlay WINDow TRACe Y SCALe PDIVision Parameter 1 1dB Return parameter 2 2 dB 5 5 dB 10 10 dB Example DISP TRAC Y PDIV 10 127 GW INSTEK GSP 9300 Programming Manual DISPlay WIN Dow TRACe Y SCALe Set POSition Description Sets or queries the position of the on screen scale Syntax DISPlay WIN Dow TRACe Y SCALe POSition LEFT CENTer RIGHt Query Syntax DISPlay WIN Dow TRACe Y SCALe POSition Parameter LEFT Position the scale to left Return parameter CENTer Position the scale to the center RIGHt Position the scale to right Example DISP TRAC Y POS LEFT DISPlay WINDow TRACe Y SCALe Set RLEVel Description Sets or queries the Y axis reference level The units depend on the scale type logarithmic linear Syntax DISPlay WINDow TRACe Y SCALe RLEVel lt ampl gt Query Syntax DISPlay WINDow TRACe Y SCALe RLEVel Parameter lt ampl gt lt NRf gt Return parameter lt NR3 gt Example DISP TRAC Y RLEV 1 mV DISPlay WINDow TRACe Y SCALe Set RLEVel OFFSet Description Sets or queries the Y axis reference level offset Syntax DISPlay WIN Dow TRACe Y SCALe RLEVel OFFSet rel ampl Query Syntax DISPlay WINDow TRACe Y SCALe RLEVel OFF Set Parameter lt ampl gt lt NRf gt dB Return parameter lt NR3 gt 128 GW INSTEK REMOTE CONTROL
48. 01111010 z 59 00111011 123 01111011 60 00111100 124 01111100 228 GW INSTEK APPENDIX 61 00111101 125 01111101 62 00111110 gt 126 01111110 63 00111111 127 01111111 DEL 229
49. 1 T2 Ref Parameter Destination Trace gt TRACe TRACe2 TRACe3 TI or TRACe4 T2 lt Ref gt lt NR1 gt Reference level Note The destination trace cannot be the same the T1 or T2 traces Example CALC MATH LDIF TRACI TRAC2 TRAC3 20 CALCulate MATH LOFF Set Description Adds an offset to T1 the source trace and puts the result into a destination trace Syntax CALCulate MATH LOFF Destination Trace T1 offset gt Parameter lt Destination Trace gt TRACel1 TRACe2 TRACe3 source trace or TRACe4 lt offset gt lt NRf gt Offset in dB Note The destination trace cannot be the same as the source trace Example CALC MATH LOFF TRAC1 TRAC2 6 Set CALCulate NDB STATe Description Sets or queries the state of the NdB BW function Syntax CALCulate NDB STATe ON OFF 1 0 107 GW INSTEK GSP 9300 Programming Manual Query Syntax CALCulate NDB STATe Parameter 0 Turn NdB BW off 1 Turn NdB BW on OFF Turn NdB BW off ON Turn NdB BW on Return parameter 0 NdB BW is off 1 NdB BW is on Example CALC NDB STAT ON CALCulate NDB BAN Dwidth BWIDth Description Returns the NdB bandwidth measurement Query Syntax CALCulate NDB BAN Dwidth BWIDth Return parameter lt NR3 gt NdB bandwidth in Hz Example CALC NDB BAND gt 5 5e 04 Set CALCulate NORMalize STATe Description Turns the tracking generator normalization on off or queries its state Syntax CALCula
50. 2 GW INSTEK REMOTE CONTROL SENSe Commands SENSe ACPR ACHannel lt n gt BANDwidth BWIDth eee SENSe ACPR ACHannel n HLIMit SENSe ACPR ACHannel n LLIMit SENSe ACPR ACHannel n OFFSet SENSe ACPR BANDwidth BWIDth SENSe ACPR PEILIMIE a eicere etaient creen SENSe ACPR LLEIMiBE 2i eth terreni SENSe ACPR HELP STATe SENSe ACPR SPAQGG SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe ASET SPAN AUTO AVERA pE STA Terroir r tAVERage TYPE eiiiai BANDwidth BWIDth RESolution BANDwidth BWIDth RESolution AUTO 152 BANDwidth BWIDth VIDeo 153 BANDwidth BWIDth VIDeo AUTO 153 5 153 CHANnel SPACe UP 5 CNR IDELTamarker MODE CORRection CSET n2 DATA CORRection CSET n STATe 155 CORRection CSET n DELete 156 5 5 CTB CHANnel SPACe DEMod EARPhone TYPE DEMod EARPhone VOLume DEMod EARPhone GAIN
51. 22 157 hislipO INSTR LXI The LXI icon on the GSP 9300 display will flash when the Identification setting is turned on Note 37 GW INSTEK GSP 9300 Programming Manual View amp Modify The View amp Modify Configuration allows you Configuration to modify the LAN settings from the browser Press the Modify Configuration button to modify any of the configuration files A password must be entered to alter the settings Default password IxiWNpwd Note password is case sensitive Configuration of your spectrum analyzer Apply Unde Change Factory Defaulte TCP IP Configuration Automatic DHCP Mode Manual IP Address Subnet Mask Gateway DNS Server DNS hostname GSP9300 036 Description GWINSTEK GSP9300 036 HiSLIP Port 4890 Password Change Password Enter Old Password Enter New Password Confirm New Password If the Factory Defaults option is chosen the Note password will be reset back to the default password It will also be necessary to manually reset the spectrum analyzer when a message prompts you to do so on the web browser 38 GW INSTEK REMOTE CONTROL SCPI Command The SCPI Command page allows you to enter SCPI commands directly from the browser for full remote control Please see the programming manual for details A password must be entered before remote commands can be used Default password lxiWNpwd Note password is case sensitive
52. 48 SEM Limit 12 4096 TOI Limit 13 8192 Pmet Limit Fail Example STAT QUES NTR 32 Set STATus QUEStionable PTRansition Description Sets or queries the bit weight of the PTR filter for the Questionable Status register Syntax STATus QUEStionable PTRansition integer Query Syntax STATus QUEStionable PTRansition Return parameter Bit Bit Weight Description 5 32 Frequency 8 256 Uncal 9 512 Limit Fail 10 1024 ACPLimit 11 2048 SEM Limit 12 4096 TOI Limit 13 8192 Pmet Limit Fail Example STAT QUES PTR 32 STATus QUEStionable F REQuency CONDition Description Returns the bit weight of the Questionable Status Frequency Condition register Query Syntax STATus QUEStionable FREQuency CONDition 207 GW INSTEK GSP 9300 Programming Manual Return parameter Bit Bit Weight Description 5 32 Invalid Span BW Example STAT QUES FREQ COND gt 32 Set STATus QUEStionable FREQuency ENABle Description Sets or queries the Questionable Status Frequency Event Enable register Syntax STATus QUEStionable FREQuency ENABle integer Query Syntax STATus QUEStionable F REQuency ENABle Return parameter Bit Bit Weight Description 5 32 Invalid Span BW Example STAT QUES FREQ ENAB 32 STATus QUEStionable FREQuency EVENt Query Description Returns the bit weight of the Questionable Status Frequency Event register Reading this register will clear the event register Query Syntax
53. 4e 01 1 423e 01 1 419e 01 1 434e 01 1 441e 01 1 449e 01 1 460e 01 1 426e 01 n CALCulate P1 DB RESult Description Returns the P1dB result as x y coordinates Query Syntax CALCulate P1 DB RESult 111 GW INSTEK GSP 9300 Programming Manual Return parameter lt x gt lt y gt o Returns the x axis coordinate in dBm lt y gt Returns the y axis coordinate in dBm Example CALC PTDB RES gt 9 25e 00 4 12e 00 CALCulate PMETer POWer Query Description Returns the power meter power measurement Query Syntax CALCulate PMETer POWer Return parameter lt NR3 gt Power in the current Y axis unit Example CALC PMET POW gt 0 83e 01 Set CALCulate PMETer LIMit STATe Description Turns the pass fail limits on off in the Power Meter mode or queries its state Syntax CALCulate PMETer LIMit STATe ON OFF 1 0 Query Syntax CALCulate PMETer LIMit STATe Parameter 0 Turns limits off 1 Turns limits on OFF Turns limits off ON Turns limits on Return parameter 0 Turns limits off Turns limits on Example CALC PMET LIM STAT gt CALCulate PMETer LIMit FAIL Query Description Returns the pass fail judgment 112 GW INSTEK REMOTE CONTROL Query Syntax CALCulate PMETer LIMit FAIL Return parameter 0 Pass or limits are not on 1 Fail Example CALC PMET LIM FAIL gt Set CALCulate SEM STATe Descript
54. 86 SENSe SEMask WIMax CHANnel BANDwidth BWIDth SENSe SEQuence lt n gt DELete SENSe SWEep EGATe DELay SENSe SWEep EGATe LENGth 145 GW INSTEK GSP 9300 Programming Manual SENSeJ SWEep EG ATe STATe es 188 5 9 188 SENSe S Weep TIME ics siis 189 SENSe SWEep TIME AUTO CSENSE TOLRE Ferentari 189 SENSe TOLLIMit ten 190 SENSe ACPR ACHannel lt n gt BANDwidth C Set BWIDth Description Sets or queries the adjacent channel bandwidth for the selected adjacent channel Used with ACPR measurement Syntax SENSe ACPR ACHannel lt n gt BAN Dwidth BWIDth lt freq gt Query Syntax SENSe ACPR ACHannel lt n gt BAN Dwidth BWIDth Parameter lt freq gt lt NRf gt Return parameter lt NR3 gt Hz Example ACPR ACHT BAND 2 0e 6 Set SENSe ACPR ACHannel lt n gt HLIMit Description Sets or queries the high limit for the selected adjacent channel Used with ACPR measurement Syntax SENSe ACPR ACHannel lt n gt HLIMit lt ampl gt Query Syntax SENSe ACPR ACHannel lt n gt HLIMit Parameter lt ampl gt lt NRf gt power or voltage Return parameter lt NR3 gt Example ACPR ACHT HLIM 3 0e 1 146 GW INSTEK REMOTE CONTROL Set SENSe ACPR ACHannel lt
55. 9 512 Limit Fail 10 1024 ACPLimit 11 2048 SEM Limit 12 4096 TOI Limit 13 8192 Pmet Limit Fail Example STAT QUES COND gt 16 Set STATus QUEStionable ENABle Description Sets or queries the Questionable Status Event Enable register Syntax STATus QUEStionable ENABle integer Query Syntax STATus QUEStionable ENABle 205 GW INSTEK GSP 9300 Programming Manual Return parameter Bit Bit Weight Description 5 32 Frequency 8 256 Uncal 9 512 Limit Fail 10 1024 ACPLimit 11 2048 SEM Limit 12 4096 TOI Limit 13 8192 Pmet Limit Fail Example STAT QUES ENAB 4096 STATus QUEStionable EVENt Query Description Returns the bit weight of the Questionable Status Event register Reading this register will clear the event register Query Syntax STATus QUEStionable EVENt Return parameter Bit Bit Weight Description 5 32 Frequency 8 256 Uncal 9 512 Limit Fail 10 1024 ACPLimit 11 2048 SEM Limit 12 4096 TOI Limit 13 8192 Pmet Limit Fail Example STAT QUES gt 16 Set STATus QUEStionable NTRansition Description Sets or queries the bit weight of the NTR filter for the Questionable Status register Syntax STATus QUEStionable NTRansition integer Query Syntax STATus QUEStionable NTRansition 206 GW INSTEK REMOTE CONTROL Return parameter Bit Bit Weight Description 5 32 Frequency 8 256 Uncal 9 512 Limit Fail 10 1024 ACPLimit 11 20
56. GATE IN port ALARM OUT OPEN COLLECTOR REF OUT REF IN GPIB port Battery cover optional Optional battery pack RS232 iocus RS232 9 pin DSUB port IF OUT icu SMA IF Out port DVI I mae DVI video out port Supports SVGA ae O 800X600 60Hz Fan 7 GW INSTEK GSP 9300 Programming Manual Power Socket J 100 240V 50 60Hz Power Socket Battery pack Voltage 10 8V Capacity 5200mAH REF IN BNC female reference input 10 MHz REF OUT jud BNC female reference output 10MHz 500 impedance 10 MHz Security Lock ALARM OUT MNT female open collector Alarm output COLLECTOR TRIG IN GATE IN BNC female 3 3V CMOS trigger input gated sweep input Phone Q 3 5mm stereo headphone jack wired for mono operation USB B USB B Device port USB 1 1 2 0 18 GW INSTEK GETTING STARTED LAN LA RJ 45 10Base T 100Base Tx 19 GW INSTEK GSP 9300 Programming Manual Display Attenuation Date Marker Function level and time information LXI icon menu Scale and Sweep Reference aiia settings level Trace Detection Traces and settings waveforms Unassigned tti Sweep sering L icons progress m bar S E Sweep Pd N Trigger Entry Frequency Bandwidth Status icons Pre amp Message settings and USB area settings Scale Displays the vertical scale of the vertical grid Referenc
57. K GSP 9300 Programming Manual MMEMory DELete Set Description Deletes the designated file from the current directory Syntax MMEMory DELete src file name Parameter src file name Example MMEM DEL QuickJpgl jpg MMEMory DESTination Set Description Sets the destination directory for memory related commands When you use a single USB drive SD card with multiple partitions inside the system will automatically name these partitions in the numeric order so you need to specify the partition number The same situation applies when you use a USB hub to extend the number of USB ports When a hub is used all the partitions from all the attached devices are numbered in numerical order from the first port to the last port If a partition number is not supplied the system will default to partition 1 For example MMEM DEST USB0 MMEM DEST USB Syntax MMEMory DESTination LOCAL USB lt n gt SD lt n gt Parameter LOCAL USB lt n gt NRI SD n NRI Example MMEM DEST SD GW INSTEK REMOTE CONTROL MMEMory LOAD CORRection Set Description Loads correction data from a file to the internal memory Syntax MMEMory LOAD CORRection corr num src file name Parameter corr num NRI correction set 1 5 src file name XXX cor Example MMEM LOAD CORR 2 test cor MMEMory LOAD LIMit Set Description Loads limit l
58. L Set SENSe DEMod EARPhone TYPE Description Sets or queries the demodulation type for the Ear Phone Out demodulation function Syntax SENSe DEMod EARPhone TYPE AM FM Query Syntax SENSe DEMod EARPhone TYPE Parameter AM AM demodulation FM FM demodulation Example DEM EARP TYPE AM Set SENSe DEMod EARPhone VOLume Description Sets or queries the volume setting for the demodulation function Syntax SENSe DEMod EARPhone VOLume integer Query Syntax SENSe DEMod EARPhone VOLume Parameter integer NRT1 0 15 Return parameter Example DEM EARP VOL 7 Set SENSe DEMod EARPhone GAIN Description Sets or queries the gain setting for the demodulation function Syntax SENSe DEMod EARPhone GAIN lt rel_ampl gt Query Syntax SENSe DEMod EARPhone GAIN Parameter lt rel_ampl gt NR1 0 18 6dB steps Return parameter Example DEM EARP GAIN 6 157 GW INSTEK GSP 9300 Programming Manual Set SENSe DEMod FILTer LPASs Description Sets or queries the low pass filter settings for the AM FM Analysis function Syntax SENSe DEMod FILTer LPASs LEVel lt n gt Bypass Query Syntax SENSe DEMod FILTer LPASs Parameter Bypass Sets the low pass filter to bypass Return parameter lt n gt lt NR1 gt 1 5 The filters 1 to 5 are shown in the table below The GSP 9300 will automatically detect the signal frequency AM FM Signal Frequency
59. LIM 3 0e 1 Set SENSe ACPR LLI Mit Description Sets or queries the low limit for the main channel Used with ACPR measurement Syntax SENSe ACPR LLIMit lt ampl gt Query Syntax SENSe ACPR LLI Mit Parameter lt ampl gt lt NRf gt power or voltage Return parameter lt NR3 gt Example ACPR ACHT LLIM 5 0e 1 SENSe ACPR HELP STATe Set Description Turns the on screen help on off Syntax SENSe ACPR HELP STATe OFF ON 0 1 Parameter 0 Turn help off 1 Turn help on OFF Turn help off ON Turn help on Example ACPR HELP STAT ON GW INSTEK REMOTE CONTROL Set SENSe ACPR SPACe Description Sets or queries the channel spacing between the main channels Syntax SENSe ACPR SPACe lt freq gt Query Syntax SENSe ACPR SPACe Parameter lt freq gt lt NRf gt Return parameter lt NR3 gt Hz Example ACPR SPAC 2 0e 6 Set SENSe ASET AMPLitude Description Sets or queries the autoset amplitude floor level Syntax SENSe ASET AMPLitude lt ampl gt Query Syntax SENSe ASET AMPLitude Parameter ampl lt NRf gt power or voltage Return parameter lt NR3 gt Example 5 8 0e 1 Set SENSe ASET AMPLitude AUTO Description Sets autoset amplitude floor level to auto or manual or queries its state Syntax SENSe ASET AMPLitude AUTO OFF ON 0 1 Query Syntax SENSe ASET AMPLitude AUTO Parameter 0 Turn autoset amplitude floor to manual Turn autos
60. M FM demodulation Syntax TRIGger SEQuence DEMod LEVel lt NRf gt Query Syntax TRIGger SEQuence DEMod LEVel Parameter lt NRf gt AM unit FM unit Hz Return parameter lt NR3 gt Example TRIG DEM LEV 10 Set TRIGger SEQuence DEMod MODE Description Sets the triggering mode for the AF Trigger in AM FM demodulation Syntax TRIGger SEQuence DEMod MODE NORMal SINGle CONTinuous Query Syntax TRIGger SEQuence DEMod MODE Parameter NORMal Normal trigger mode Return parameter SINGle Single trigger CONTinuous Continuous trigger Example TRIG DEM MODE CONT Set TRIGger SEQuence DEMod SLOPe Description Sets the trigger slope Syntax iTRIGger SEQuence DEMod SLOPe POSitive NEGative Query Syntax TRIGger SEQuence DEMod SLOPe 221 GW INSTEK GSP 9300 Programming Manual Parameter POSitive Positive slope Return parameter NEGative Negative slope Example TRIG DEM SLOP POS TRIGger SEQuence DEMod SOURce Set Description Sets the triggering source for AM FM demodulation Syntax TRIGger SEQuence DEMod SOURce IMMediate VIDeo Parameter IMMediate Free run trigger VIDeo Trigger on the video signal level Example TRIG DEM SOUR IMM Set TRIGger SEQuence DEMod TIME STARt Description Sets the trigger start time of the AF trigger for the AM FM demodulation function Syntax TRIGger SEQuence DEMod TIME STARt lt NRf gt Query Syntax T
61. MMEMory CATalog Query Description Returns a list of all the files that have been saved to the local memory Query Syntax MMEMory CATalog Example MMEM CAT LocalState sta QuickJpg jpg Quick pg1 jpg 134 GW INSTEK REMOTE CONTROL MMEMory CDlIRectory Set Description Sets the source directory for memory related commands When you use a single USB drive SD card with multiple partitions inside the system will automatically name these partitions in the numeric order so you need to specify the partition number The same situation applies when you use a USB hub to extend the number of USB ports When a hub is used all the partitions from all the attached devices are numbered in numerical order from the first port to the last port If a partition number is not supplied the system will default to partition 1 For example MMEM CDI USBO MMEM CDI USB Syntax MMEMory CDlIRectory LOCAL USB lt n gt SD lt n gt Parameter LOCAL USB lt n gt lt NRI gt SD lt n gt lt NRI gt Example MMEM CDIR USB Example2 MMEM CDIR USB3 MMEMory COPY Set Description Copies a designated file from the current file directory to the destination directory The file can be renamed after it is copied Syntax MMEMory COPY src file name dest file name Parameter src file name dest file name Example MMEM COPY QuickJpgl jpg QuickJpg2 jpg 135 GW INSTE
62. MOTE CONTROL Syntax SENSe SEMask W3GPP FDD MO Power LEVel lt n gt Query Syntax SENSe SEMask W3GPP FDD MOPower Parameter NONE Return parameter LEVEL lt n gt n 1 for 43 lt P n 2 for 39 lt P lt 43 n 3 for 31 lt P lt 39 n 4 for P lt 31 Example SEM W3GPP FDD MOP SENSe SEMask W3GPP FDD TRANsmit Set MODE Description Selects or queries the transmit mode of the FDD 3GPP test Base station or User Equipment Syntax SENSe SEMask W3GPP FDD TRANsmit MODE BS UE Query Syntax SENSe SEMask W3GPP FDD TRANsmit MODE Parameter BS Base station Return parameter UE User Equipment Example SEM W3GPP FDD TRAN MODE UE Set SENSe SEMask W3GPP TDD CHIP RATE Description Selects or queries the chip rate for TDD 3GPP tests Syntax SENSe SEMask W3GPP TDD CHIP RATE 3 84e 6 1 28e 6 7 68e 6 Query Syntax SENSe SEMask W3GPP TDD CHIP RATE Parameter 3 84e 6 lt freq gt Return parameter 1 28e 6 lt freq gt 7 68e 6 lt freq gt Example SEM W3GPP TDD CHIP RATE 3 84e 6 185 GW INSTEK GSP 9300 Programming Manual Set SENSe SEMask W3GPP TDD MO Power Description Selects or queries Max Out Power for TDD 3GPP tests See the user manual for a list of the power levels Syntax SENSe SEMask W3GPP TDD MO Power LEVel lt n gt Query Syntax SENSe SEMask W3GPP TDD MOPower Parameter LEVEL lt n gt For 3GPP TDD BS 3 84 and Return
63. N 15 00001111 SI 79 01001111 O 16 00010000 DLE 80 01010000 P 17 00010001 DC1 81 01010001 Q 18 00010010 DC2 82 01010010 R 19 00010011 DC3 83 01010011 S 20 00010100 DC4 84 01010100 T 21 00010101 NAK 85 01010101 U 22 00010110 SYN 86 01010110 V 23 00010111 ETB 87 01010111 W 227 GW INSTEK GSP 9300 Programming Manual 24 00011000 CAN 88 01011000 X 25 00011001 EM 89 01011001 Y 26 00011010 SUB 90 01011010 Z 27 00011011 ESC 91 01011011 28 00011100 FS 92 01011100 29 00011101 GS 93 01011101 30 00011110 RS 94 01011110 31 00011111 US 95 01011111 _ 32 00100000 Space 96 01100000 33 00100001 97 01100001 a 34 00100010 98 01100010 b 35 00100011 99 01100011 c 36 00100100 100 01100100 d 37 00100101 101 01100101 e 38 00100110 amp 102 01100110 f 39 00100111 103 01100111 g 40 00101000 104 01101000 h 41 00101001 105 01101001 i 42 00101010 106 01101010 j 43 00101011 107 01101011 k 44 00101100 108 01101100 1 45 00101101 109 01101101 m 46 00101110 110 01101110 n 47 00101111 111 01101111 o 48 00110000 0 112 01110000 p 49 00110001 1 113 01110001 q 50 00110010 2 114 01110010 r 51 00110011 3 115 01110011 s 52 00110100 4 116 01110100 t 53 00110101 5 117 01110101 u 54 00110110 6 118 01110110 v 55 00110111 7 119 01110111 w 56 00111000 8 120 01111000 x 57 00111001 9 121 01111001 y 58 00111010 122
64. OXXX TX X X X 47 GW INSTEK GSP 9300 Programming Manual Write 1 Basic YO Line Control USB Control Select or Enter C Return Data Read Operation Bytes to Read No Error 104 Query Read Read Status Byte Clear View mixed ASCI hexadecima Y Clear Buffer GW INSTEK REMOTE CONTROL Command Syntax Full compatibilit Compatible IEEE488 2 P y Standard SCPI 1999 Full compatibility Command SCPI Standard Commands for Programmable Structure Instruments commands follow a tree like structure organized into nodes Each level of the command tree is a node Each keyword in a SCPI command represents each node in the command tree Each keyword node of a SCPI command is separated by a colon For example the diagram below shows an SCPI sub structure and a command example CALCulate CALCulate CTB STATe ON CTB RESult STATe STATe OFF ON Command types There are a number of different instrument commands and queries A command sends instructions or data to the unit and a query receives data or status information from the unit Command types Simple A single command with without a parameter Example RST GW INSTEK GSP 9300 Programming Manual Query A query is a simple or compound command followed by a question mark 0 A parameter data is returned Example CALCulate CSO STATe Compound Two or more commands
65. PE USER FACTory Query Syntax SYSTem PRESet TY PE Parameter USER User defined preset Return parameter FACTory Factory default Example SYST PRES TYPE USER SYSTem PRESet USER SAVE Set Description Save the current environment as the User preset settings Syntax SYST PRES USER SAVE SYSTem REBoot Set Description Restart Reboot the GSP 9300 Syntax SYSTem REBoot SYSTem SHUTdown Set Description Shut down the GSP 9300 Syntax SYST SHUT Set SYSTem TIME Description Sets the system time Syntax SYSTem TIME lt hour gt lt minute gt lt second gt Query Syntax SYSTem TIME 199 GW INSTEK GSP 9300 Programming Manual Parameter lt hour gt Return parameter lt minute gt NRI second NRI Example SYST TIME 19 26 30 SYSTem UPDate Set Description Updates the system with new firmware from files located on an external USB drive The firmware files must be included in the directory named gsp931 Warning Do not perform this command if the update file is not on the USB drive If the update file is not on the USB drive it will cause the instrument to continuously loop until a USB drive with the appropriate update file is inserted into the USB drive Syntax SYST UPD SYSTem VERSion HARDware Query Description Returns the system firmware version Query Syntax SYSTem VERSion HARDware Return parameter lt string gt T X X X X Example SYST VERS HARD g
66. PEAK CTRack STATe ON OFF 1 0 Query Syntax CALCulate MARKer PEAK CTRack STATe GW INSTEK REMOTE CONTROL Parameter 0 Turn peak track off Turn peak track on OFF Turn peak track off ON Turn peak track on Return parameter 0 Peak track is off Peak track is on Example CALC MARK PEAK CTR STAT ON CALCulate MARKer PEAK DATA Description Returns all the top 10 peak data values in CSV format returns the contents of the peak table The csv data data contains 10 pairs of data from the top 10 peaks Each pair includes the peak frequency and the peak amplitude There are a total of 10 pairs of data points 20 data entries in total for the csv data data Query syntax CALCulate MARKer PEAK DATA Return parameter csv data pk 1 freq pk 1 amp pk 10 freq pk 10 amp Example CALC MARK PEAK DATA gt 1 250e 08 5 052e 01 1 065000000e 09 Set CALCulate MARKer PEAK EXCursion Description Sets or queries the peak excursion value Syntax CALCulate MARKer PEAK EXCursion rel ampl Query Syntax CALCulate MARKer PEAK EXCursion Parameter rel ampl Peak excursion dB offset from threshold Return parameter lt NR3 gt Peak excursion in dB Example CALC MARK PEAK EXC 6 db 101 GW INSTEK GSP 9300 Programming Manual Set CALCulate MARKer PEAK SORT TY PE Description Sets or queries the peak sort type for the peak table Synt
67. Play DEMod WINDow TRACe X SCALe RPOSition lt integer gt Query Syntax DISPlay DEMod WINDow TRACe X SCALe RPOSition Parameter integer lt NR1 gt 1 10 Return parameter Example DISP DEM TRAC X RPOS 2 DISPlay DEMod WINDow TRACe X Set SCALe RVALue Description Sets or queries the Reference value time Syntax DISPlay DEMod WINDow TRACe X SCALe RVALue lt time gt Query Syntax DISPlay DEMod WINDow TRACe X SCALe RVALue Parameter lt time gt lt NRf gt Return parameter lt NR3 gt Seconds Example DISP DEM TRAC X RVAL 2 ms DISPlay DEMod WINDow TRACe Y SCALe AUTO Set Description Sets the vertical display scale to auto for AM FM demodulation Syntax DISPlay DEMod WINDow TRACe Y SCALe AUTO Example DISP DEM TRAC Y AUTO 120 GW INSTEK REMOTE CONTROL DISPlay DEMod WINDow TRACe Y Set SCALe PDIVision Description Sets or queries the Y axis scale per division Syntax DISPlay DEMod WINDow T RACe Y SCALe PDIVision lt NRf gt Query Syntax DISPlay DEMod WINDow T RACe Y SCALe PDIVision Parameter lt NRf gt AM Unit FM Unit Hz Return parameter lt NR3 gt AM Unit FM Unit Hz Example DISP DEM TRAC Y PDIV 2 3e 1 DISPlay DEMod WINDow TRACe Y Set SCALe RPOSition Description Sets or queries the Reference Position of the trace for AM FM demodulation y axis grid division Syntax DISPlay DEM
68. RIGger SEQuence DEMod TIME STARt Parameter lt NRf gt Time value in seconds Return parameter Example TRIG DEM TIME STAR 2 000 2 Set TRIGger SEQuence DEMod TIME STOP Description Sets the trigger stop time of the AF trigger for the AM FM demodulation function Syntax TRIGger SEQuence DEMod TIME STOP lt NRf gt Query Syntax TRIGger SEQuence DEMod TIME STOP 222 GW INSTEK REMOTE CONTROL Parameter lt NR amp Time value in seconds Return parameter Example TRIG DEM TIME STOP 4 000e 2 Set TRIGger SEQuence EXTernal SLOPe Description Sets the external trigger slope Syntax TRIGger SEQuence EXTernal SLOPe POSitive NEGative Query Syntax TRIGger SEQuence EXTernal S LOPe Parameter POSitive Positive slope Return parameter NEGative Negative slope Example TRIG EXT SLOP POS Set TRIGger SEQuence MODE Description Sets the triggering mode Syntax TRIGger SEQuence MODE NORMal SINGle CONTinuous Query Syntax STRIGger SEQuence MODE Parameter NORMal Normal trigger mode Return parameter SINGle Single trigger CONTinuous Continuous trigger Example TRIG MODE CONT Set TRIGger SEQuence PMETer SOURce Description Sets the triggering source to immediate or external Syntax TRIGger SEQuence PMETer SOURce IMMediate EXTernal Query Syntax TRIGger SEQuence PMETer SOURce 223 GW INSTEK GSP 9300 Programming Manual
69. Return parameter Bit Bit Weight Description 0 1 Offset 1 Upper fail 1 2 Offset 1 Lower fail 2 4 Offset 2 Upper fail 3 8 Offset 2 Lower fail 4 16 Offset 3 Upper fail 5 32 Offset 3 Lower fail 6 64 Offset 4 Upper fail 7 128 Offset 4 Lower fail 8 256 Offset 5 Upper fail 9 512 Offset 5 Lower fail Example STAT QUES SEML NTR 3 214 GW INSTEK REMOTE CONTROL STATus QUEStionable SEM Limit Set PTRansition Description Sets or queries the bit weight of the PTR filter for the Questionable Status SEM Limit register Syntax STATus QUEStionable SEMLimit PTRansition integer Query Syntax STATus QUEStionable SEMLimit PTRansition Return parameter Bit Bit Weight Description 0 1 Offset 1 Upper fail 1 2 Offset 1 Lower fail 2 4 Offset 2 Upper fail 3 8 Offset 2 Lower fail 4 16 Offset 3 Upper fail 5 32 Offset 3 Lower fail 6 64 Offset 4 Upper fail 7 128 Offset 4 Lower fail 8 256 Offset 5 Upper fail 9 512 Offset 5 Lower fail Example STAT QUES SEML PTR 3 STATus QUEStionable TOlLimit CONDition Description Returns the bit weight of the Questionable Status TOI Limit Condition register Query Syntax STATus QUEStionable TOILimit CON Dition Return parameter Bit Bit Weight Description 0 1 314 lower fail 1 2 34 upper fail Example STAT QUES TOIL COND gt 215 GW INSTEK GSP 9300 Programming Manual Set STATus QUEStionable TOILimit ENABle Descript
70. Se SEMask W3GPP DUPLex TYPE FDD TDD Query Syntax SENSe SEMask W3GPP DUPLex TY PE Parameter FDD Frequency division duplexing Return parameter TDD Time division duplexing Example SEM W3GPP DUPL TYPE FDD 183 GW INSTEK GSP 9300 Programming Manual SENSe SEMask W3GPP FDD ADDition Set LIMit Description Selects or queries the operating band used for the 3GPP FDD additional requirements See the user manual for a list of the 3GPP operation bands Syntax SENSe SEMask W3GPP FDD ADDition LI Mit NONE BAND lt n gt Query Syntax SENSe SEMask W3GPP FDD ADDition LIMit Parameter NONE Return parameter BAND lt n gt When n band number Example SEM W3GPP FDD ADD LIM BANDA SENSe SEMask W3GPP FDD ADDition Set MOPower Description Selects or queries Max Out Power for the 3GPP additional requirements for the selected offset Please see the user manual for a list of the selectable maximum power output levels Syntax SENSe SEMask W3GPP FDD ADDition MOPower NONE LEVel lt n gt Query Syntax SENSe SEMask W3GPP FDD ADDition MOPower Parameter NONE Return parameter LEVEL lt n gt n 1 for 6 lt P lt 20 n 2 for P lt 6 Example SEM W3GPP FDD ADD MOP LEVI Set SENSe SEMask W3GPP FDD MOPower Description Selects or queries Max Out Power for the selected offset Please see the user manual for a list of the selectable maximum power output levels GW INSTEK RE
71. Se HARMonic FUNDamental FREQuency Parameter freq lt NRf gt Return parameter lt NR3 gt Hz Example SENS HARM FUND FREQ 1 0e 6 163 GW INSTEK GSP 9300 Programming Manual Set SENSe HARMonic NUMBer Description Sets or queries the harmonic number Syntax SENSe HARMonic NUMBer lt NR1 gt Query Syntax SENSe HARMonic NUMBer Parameter NRI Harmonic number Return parameter lt NR1 gt Returns the harmonic number Example SENS HARM NUMB 3 SENSe LIMit lt n gt DELete Set Description Deletes the chosen limit line Syntax SENSe LIMit lt n gt DELete Parameter lt n gt NRI limit line number Example LIM3 DEL Set SENSe JITTer OFFSet STARt Description Sets or queries the start offset for phase jitter measurements Syntax SENSe JITTer OF FSet STARt freq Query Syntax SENSe TTer OF FSet STARt Parameter lt freq gt lt NRf gt Return parameter lt NR3 gt Hz Example JITT OFFS STAR 1 0e 7 Set SENSe TTer OFFSet STOP Description Sets or queries the stop offset for phase jitter measurements GW INSTEK REMOTE CONTROL Syntax SENSe TTer OF FSet STOP freq Query Syntax SENSe TTer OFFSet STOP Parameter lt freq gt lt NRf gt Return parameter lt NR3 gt Hz Example JITT OFFS STOP 1 5e 7 Set SENSe NDB BAN Dwidth BWIDth Description Sets or queries the NdB amp
72. Spectrum Analyzer GSP 9300 PROGRAMMING MANUAL GW INSTEK PART NO 82SP 930A0E01 50 9001 CERTIFIED MANUFACTURER GW INSTEK This manual contains proprietary information which is protected by copyright All rights are reserved No part of this manual may be photocopied reproduced or translated to another language without prior written consent of Good Will company The information in this manual was correct at the time of printing However Good Will continues to improve products and reserves the rights to change specification equipment and maintenance procedures at any time without notice Good Will Instrument Co Ltd No 7 1 Jhongsing Rd Tucheng Dist New Taipei City 236 Taiwan GW INSTEK Table of Contents Table of Contents SAFETY INSTRUCTIONS caca ibd voncseanansesudiesaeontaneiveniiatis 2 GETTING STARTED ori tento b ERE ROI ED etam and eaten pis 7 GSP 9300 Introduction ii arre 8 ACCEeSSOTIBS eR a reto dura u unus 11 Appearance three venei 12 REMOTE CONTRON s toast I abIMIx ERR PRSE URFEF IU RV TUE T Mad r 25 Interface Configuration 26 Command Syntax secerneren 49 sses 54 eee 64 227 Binary Coded Decimal Table 227 GW INSTEK GSP 9300 Programming Manual SAFETY INSTRUCTIONS This chapter contains important safety instructions that you must follow during operation and storage Rea
73. TAT 1 CALCulate LIMit lt n gt TRACe Set Description Creates a limit line from the currently selected trace with a user defined offset Syntax CALCulate LIMit lt n gt TRACe offset 96 GW INSTEK REMOTE CONTROL Parameter lt n gt NRI limit line 1 5 lt offset gt lt NR3 gt in dB Example CALC LIM2 TRAC 10 Set CALCulate LIMit TYPE Description Sets or queries the Pass Fail conditions for the limit line testing Syntax CALCulate LIMit TYPE ALL MAX MIN Query Syntax CALCulate LIMit TYPE Parameter ALL All in Return Parameter MAX Max In MIN Min In Example CALC LIM TYPE ALL CALCulate MARKer AOFF Set Description Turns all the markers off Syntax CALCulate MARKer AOFF Example CALC MARK AOFF CALCulate MARKer lt n gt FCOunt Set RESolution Description Sets or queries the frequency counter resolution in Hz for the selected marker Syntax CALCulate MARKer lt n gt FCOunt RESolution freq Query Syntax CALCulate MARKer lt n gt FCOunt RESolution Parameter lt n gt lt NR1 gt Maker number 1 6 lt freq gt Frequency resolution in Hz 97 GW INSTEK GSP 9300 Programming Manual Return parameter lt freq gt Frequency resolution in Hz Note Only one marker can be selected at a time to use the marker counter function The selected marker counter will disable the previously selected marker counter Only 1000 100 10 1 Hz are meaningful
74. This is the summary bit for the Demod Fail Register 60 GW INSTEK REMOTE CONTROL Questionable Status Frequency Register Overview The Questionable Status Frequency Register indicates if the span or BW settings are invalid Bit Summary Bit Weight Description 5 32 Invalid Span or BW This bit is set to 1 when there is an invalid span or bandwidth setting during the frequency count Questionable Status ACP Limit Register Overview The Questionable Status ACP Limit Register Group indicates if any adjacent channel limits have been tripped Bit Summary Bit Weight Description 0 1 Main Channel High Fail This bit is set to 1 when the Main CH HLimit has been violated 1 2 Main Channel Low Fail This bit is set to 1 when the Main CH LLimit has been violated 2 4 Adjl High Fail This bit is set to 1 when the ADJCH 1 HLimit has been violated 3 Adjl Low Fail This bit is set to 1 when the ADJCH 1 LLimit has been violated 4 16 Adj2 High Fail This bit is set to 1 when the ADJCH 2 HLimit has been violated 5 32 Adj2 Low Fail This bit is set to 1 when the ADJCH 2 LLimit has been violated 6 64 Adj3 High Fail This bit is set to 1 when the ADJCH 3 HLimit has been violated 7 128 Adj3 Low Fail This bit is set to 1 when the ADJCH 3 LLimit has been violated GW INSTEK GSP 9300 Programming Manual Questionable Status SEM Limit Register Overview The Questionable Status SEM Limit Register Group indicates
75. XTernal SLOPe TRIGger SEQuence MODE TRIGger SEQuence PMETer SOURCcCe TRIGger SEQuence SOURCE TRIGger SEQuence VIDeo FREQuency TRIGger SEQuence VIDeo LEVel e TRIGger SEQuence VIDeo SLOPe TUNIT PME Tet POWe Bf eee 226 UNIT POWE sinini ra a ENNE ANTR 226 73 GW INSTEK GSP 9300 Programming Manual SCPI Commands CLS Set Description The CLS command clears the Standard Event Status Operation Status and Questionable Status registers The corresponding Enable registers in each of the above registers are not cleared If a NL newline code immediately precedes a CLS command the Error Que and the MAV bit in the Status Byte Register is also cleared Syntax CLS IDN auery Description Queries the manufacturer model number serial number and firmware version of the instrument Query Syntax IDN 74 GW INSTEK REMOTE CONTROL Return parameter lt string gt Returns the instrument identification as a string in the following format GWINSTEK GSP 9300 XXXXXXXX T X X X X Manufacturer GWINSTEK Model number GSP 9300 Serial number XXXXXXXX Firmware version T X X X X Set ESE Description Sets or queries the Standard Event Status Enable register Syntax ESE NRI Query Syntax ESE Parameter NRI 0 255 Return parameter NRI Returns the b
76. able from zi the network to the rear panel LAN port 27 GW INSTEK GSP 9300 Programming Manual Settings 1 Press S More F 7 gt RmtInterface F1 gt LAN F2 gt LAN Config F1 to set the LAN settings IP Address F7 Sets the IP address Subnet Mask F2 Sets the subnet mask Default Gateway F3 Sets the default gateway DNS Server F4 Sets the DNS server address LAN Config F5 Toggles the LAN configuration between DHCP and manual settings Hint Use dotted decimal notation when entering IP addresses ie 172 16 20 8 2 Press Apply F6 to confirm the LAN configuration settings Display Icon The LXI icon turns green when connected to a LAN and will flash if the Identification setting is on see page 37 Set Password The password on the LXI webpage can be set from the spectrum analyzer The password is shown in the system information By default the password is set to xi WNpwd 3 Press S9 More F7 Rmtinterface Config F1 LAN F2 LXIPassword F3 to set the password 4 Enter the password using the F1 F7 keys as shown below or use the numeric keypad to enter numbers 28 GW INSTEK REMOTE CONTROL Limitations e No spaces e Only 1 9 az characters allowed A B qn C a D b FGHIJ E KLMNO Lowercase lt d Rename gt PQRST Return e XQ UVWXY Z Return J Retu
77. ail 7 128 Adj3 low fail Example STAT QUES ACPL COND Set STATus QUEStionable ACPLimit ENABle Description Sets or queries the Questionable Status ACP Limit Event Enable register Syntax STATus QUEStionable ACPLimit ENABle integer Query Syntax STATus QUEStionable ACPLimit ENABle Return parameter Bit Bit Weight Description 0 1 Main channel high fail 1 2 Main channel low fail 2 4 Adj high fail 3 8 Adj1 low fail 4 16 Adj2 high fail 5 32 Adj2 low fail 6 64 Adj3 high fail 7 128 Adj3 low fail Example STAT QUES ACPL ENAB 3 STATus QUEStionable ACPLimit EVENT Description Returns the bit weight of the Questionable Status ACP Limit Event register Reading this register will clear the event register Query Syntax STATus QUEStionable ACPLimit EVENt 210 GW INSTEK REMOTE CONTROL Return parameter Bit Bit Weight Description 0 1 Main channel high fail 2 Main channel low fail 2 4 Adj1 high fail 3 8 Adjl low fail 4 16 Adj2 high fail 5 32 Adj2 low fail 6 64 Adj3 high fail 7 128 Adj3 low fail Example STAT QUES ACPL 23 STATus QUEStionable ACPLimit Set NTRansition Description Sets or queries the bit weight of the NTR filter for the Questionable Status ACP Limit register Syntax STATus QUEStionable ACPLimit NTRansition integer Query Syntax STATus QUEStionable ACPLimit NTRansition Return parameter Bit Bit Weight Description 0 1 Main channe
78. anual 1 TG step level is set to automatic Example SOUR POW STEP AUTO 1 192 GW INSTEK REMOTE CONTROL Set SOURce POWer MODE Description Sets the Power Sweep mode Syntax SOURce POWer MODE FlXed SWEep Query Syntax SOURce POWer MODE Parameter FIXed Power sweep off Return parameter SWEep Power sweep on Example SOUR POW MODE FIX Set SOURce POWer SWEep Description Sets the Power Sweep offset level Syntax SOURce POWer SWEep lt rel_ampl gt Query Syntax SOURce POWer SWEep Parameter lt rel_ampl gt lt NRf gt 5 to 5 dB Return parameter lt NR3 gt dB Example SOUR POW SWE 5 db 193 GW INSTEK GSP 9300 Programming Manual SYSTem Commands SSYSTem ALARm STATe eese SXSIem CLOCkzn DATE iaiteteeteieit toits SSYSTem CLOCk n2 MODE SYSTem CLOCk n STATe SYSTem CLOCK lt n gt TIME eene SSYSTem COMMunicate GPIB SELF ADDhRess 196 SYSTem COMMunicate LANReset eee 197 SSYSTem COMMunicate SERial RECeive BAUD 197 SYSTem COMMunicate USB MODE SON OPE DE IBS RETE SYSTem ER Ror CLE at eese SSYSTem ERRor NEXT m SY STen KLOGCk ISYSTenzPRESE eere rers SYSTem PRESet TYPE AT SYSTem PRESet USER SAVE eere ISYSTemi RBDBOOEb av eric ripa da RO ORIS RUN SYSTem SHUTdown M a SSYSTem TIME MSY ST Gt UP Date ede eer
79. ax CALCulate MARKer PEAK SORT TY PE FREQuency AMPLitude Query Syntax CALCulate MARKer PEAK SORT TY PE Parameter FREQuency Sort by frequency Return parameter AMPLitude Sort by amplitude Example CALC MARK PEAK SORT TYPE FREQ Set CALCulate MARKer PEAK TABLe STATe Description Sets or queries the state of the Peak Table Syntax CALCulate MARKer PEAK TABLe STATe ON OFF 1 0 Query Syntax CALCulate MARKer PEAK TABLe STATe Parameter 0 Turn peak table off 1 Turn peak table on OFF Turn peak table off ON Turn peak table on Return parameter 0 peak table is off 1 peak table is on Example CALC MARK PEAK TABL STAT ON Set CALCulate MARKer PEAK THReshold Description Sets or queries the peak threshold value Syntax CALCulate MARKer PEAK THReshold lt ampl gt Query Syntax CALCulate MARKer PEAK THReshold Parameter lt ampl gt Peak Threshold level GW INSTEK REMOTE CONTROL Return parameter lt NR3 gt Peak threshold Note the unit returned depends on the currently set vertical units Example CALC MARK PEAK THR 3 dBm CALCulate MARKer PEAK THReshold Set STATe Description Sets or queries the state of the Peak Threshold Syntax CALCulate MARKer PEAK THReshold STATe Query Syntax CALCulate MARKer PEAK THReshold STATe Parameter 0 Turn peak threshold off Turn peak threshold on OFF Turn peak threshold off ON Tu
80. ay line on OFF Turn display line off ON Turn display line on Return parameter 0 The display line is off 1 The display line is on Example DISP TRAC Y DLIN STAT ON DISPlay WIN Dow TRACe Y SCALe AUTO Description Equivalent to Amplitude gt Autoscale F4 when operating via the front panel Syntax DISPlay WIN Dow TRACe Y SCALe AUTO ONCE Parameter lt ONCE gt Compulsory parameter Example DISP TRAC Y AUTO ONCE DISPlay WIN Dow TRACe Y SCALe Set NRLevel Description Sets or queries the normalized reference level for the TG option 126 GW INSTEK REMOTE CONTROL Syntax DISPlay WINDow TRACe Y SCALe NRLevel lt ampl gt Query Syntax DISPlay WINDow TRACe Y SCALe NRLevel Parameter lt ampl gt lt NRf gt Power or voltage in the current Y axis unit Return parameter lt NR3 gt Example DISP TRAC Y NRLevel 5 dBm DISPlay WINDow TRACe Y SCALe Set NRPosition Description Sets or queries the position of the normalized reference level The 0 10 Y axis grid divisions correspond to the bottom top grid divisions Syntax DISPlay WINDow TRACe Y SCALe NRPosition lt integer gt Query Syntax DISPlay WINDow TRACe Y SCALe NRPosition Parameter integer 0 10 Return parameter Example DISP TRAC Y NRP 5 DISPlay WINDow TRACe Y SCALe Set PDIVision Description Sets or queries the Y axis scale div when the amplitude
81. been configured for RS232 remote control page 35 idn This should return the Manufacturer Model 35 GW INSTEK GSP 9300 Programming Manual number Serial number and Firmware version in the following format e GWINSTEK GSP9300 XXXXXXXX T X X X X Manufacturer GWINSTEK Model number GSP9300 Serial number XXXXXXXX Firmware version T X X X For further details please see the programming Note manual available on the GW Instek web site www gwinstek com 36 GW INSTEK REMOTE CONTROL LXI Browser Interface and Function Check Functionality Enter the IP address of the spectrum analyzer in check a web browser after the instrument has been configured and connected to the LAN page 27 or WLAN page 30 http The web browser interface appears Welcome Page The Welcome Page lists all the LXI and LAN WLAN configuration settings as well as the instrument identification The instrument identification can be disabled from this page Instrument Welcome Page Identification ON 9 OFF LXI Device Model GSP9300 Manufacturer GWINSTEK Serial Number EN203036 Description GWINSTEK GSP9300 036 LXI Extended Functions LXI HiSLIP LXI Version 14 LXI Core 2011 Fireware Revision T2 0 1 2 DNS hostname mDNS hostname GSP9300 036 local MAC Address 00 22 24 81 7E 22 TCP IP Address 172 16 22 157 TCPIPO 172 16 22 157 inst0 INSTR TCPIPO 172 16
82. d the following before any operation to ensure your safety and to keep the instrument in the best possible condition Safety Symbols These safety symbols may appear in this manual or on the instrument Warning Identifies conditions or practices that WARNING could result in injury or loss of life Caution Identifies conditions or practices that CAUTION could result in damage to the instrument or to other properties DANGER High Voltage Attention Refer to the Manual Earth ground Terminal gt o ep Frame or Chassis Terminal GW INSTEK SAFETY INSTRUCTIONS Do not dispose electronic equipment as unsorted municipal waste Please use a separate collection facility or contact the supplier from which this instrument was purchased Safety Guidelines General Do not place any heavy object on the Guideline instrument N e Avoid severe impact or rough handling that CROTON leads to damaging the instrument Do not discharge static electricity to the instrument e Use only mating connectors not bare wires for the terminals e Ensure signals to the RF input do not exceed 30dBm e Ensure reverse power to the TG output terminal does not exceed 30dBm Do not supply any input signals to the TG output Do not block the cooling fan opening e Do not disassemble the instrument unless you are qualified Measurement categories EN 61010 1 2010 specifies the measurement cate
83. delta of the base lower frequency and base upper frequency Query syntax CALCulate TOI FREQuency STEPsize Return parameter lt NR3 gt Af Hz Example CALC TOI FREQ DIFF gt 6 65e 5 Set CALCulate TOI LIMit STATe Description Turns the TOI pass fail limit on off or queries its state Syntax CALCulate TOI LIMit STATe ONJOFF 1 0 Query Syntax CALCulate TOI LIMit STATe Parameter 0 Turns pass fail limit off 1 Turns pass fail limit on 114 GW INSTEK REMOTE CONTROL OFF Turns pass fail limit off ON Turns pass fail limit on Return parameter 0 Turns pass fail limit off Turns pass fail limit on Example CALC TOI LIM STAT ON CALCulate TOI RESult Description Returns the third order intercept and the pass fail judgments Query syntax CALCulate TOI RESult Return parameter lt 3 lower 314 order lower intercept lt lower p f gt 314 order lower pass fail judgment O pass 1 fail 3 d upper gt 314 order upper intercept lt upper p f gt 3 order lower pass fail judgment O pass 1 fail Example CALC TOI RES gt 5 5e 1 0 6 61e 1 0 Set CALCulate TOI STATe Description Turns TOI measurement on off or queries its state Syntax CALCulate TOI STATe ON OFF 1 0 Query Syntax CALCulate TOI STATe Parameter 0 Turns TOI measurement off 1 Turns TOI measurement on OFF Turns TOI measurement off ON Turns TOI measurement on Return parameter 0 TOI measurement is off 1 TOI measurement is o
84. dous wiring must be immediately destroyed and replaced in accordance to the above standard a GW INSTEK GETTING STARTED G ETTING STARTED This chapter provides a brief overview of the GSP 9300 the package contents and an introduction to the front panel rear panel and GUI GSP 9300 Introduction eee 8 Main Featutes 4 i tiem 8 Accessories ce e E CE e EN 11 Appear al Boso edo POR EIS URDU indes 12 GSP 9300 Front Panel eee 12 R at Panel uenti nitet me tit aciei ene 17 Ip 20 Status Icon Overview essere eher 23 GW INSTEK GSP 9300 Programming Manual GSP 9300 Introduction The GSP 9300 builds on the strong feature set of the GSP 930 and significantly increases performance in almost every aspect making this the most comprehensive and feature rich spectrum analyzer GW Instek has released Like the GSP 930 the GSP 9300 features a split window display to view data in spectrum topographic or spectrographic views There are also a number of additional test functions such as 2FSK 1PdB and new dedicated EMC pretest functions for EMI and EMS testing Lastly the GSP 9300 significantly reduces the sweep time and RBW filter step resolution and complexity Main Features Performance e 9kHz 3GHz bandwidth 1Hz resolution e Nominal RBW accuracy of 5 1MHz 8 1MHz e Video bandwidth 1Hz 1MHz 1 3 10 steps e Amplitude measurement
85. e Description Sets or queries the state of the Marker Noise function Syntax CALCulate MARKer lt n gt NOISe STATe ON OFF 1 0 Query Syntax CALCulate MARKer lt n gt NOISe STATe Parameter lt n gt lt NR1 gt Marker number 1 6 0 Turn marker noise off 1 Turn marker noise on OFF Turn marker noise off ON Turn marker noise on Return parameter 0 Marker noise is off 1 Marker noise is on Example CALC MARK2 NOIS STAT ON 99 GW INSTEK GSP 9300 Programming Manual Set CALCulate MARKer lt n gt NOISe Y Description Returns the normalized noise level over a BW of 1Hz from the marker position Query Syntax CALCulate MARKer lt n gt NOISe Y Parameter lt n gt NRI Maker number 1 6 Return parameter lt NR3 gt Normalized noise level in the Y axis unit Example CALC MARKT NOIS Y gt 1 166e 2 CALCulate MARKer lt n gt PEAK Set Description Sets the selected marker to the selected peak Query Syntax CALCulate MARKer lt n gt PEAK MAXimum MINimum NEXT RIGHt LEFT Parameter lt n gt NRI Marker number 1 6 MAXimum Highest peak value MIMimum Lowest peak value NEXT Next peak RIGHt Next peak right LEFT Next peak left Example CALC MARK1 PEAK NEXT Set CALCulate MARKer PEAK CTRack STATe Description Sets or queries the state of the Peak Track function The Peak Track function only applies to the currently selected marker Syntax CALCulate MARKer
86. e CALC MARK1 TYPE NORM 105 GW INSTEK GSP 9300 Programming Manual Set CALCulate MARKer lt n gt X Description Sets or returns the marker position in Hz Syntax CALCulate MARKer lt n gt X freq Query Syntax CALCulate MARKer lt n gt X Parameter lt n gt lt NR1 gt Marker number 1 6 Return parameter lt freq gt Hz Example CALC MARKA X 2 0e 6 CALCulate MARKer lt n gt Y Description Returns the marker s vertical position in the current unit Query Syntax CALCulate MARKer n Y Parameter n NRI Marker number 1 6 Return parameter lt NR3 gt Power or voltage Example CALC MARKT Y 2 5 43e4 CALCulate MATH PDIF Set Description Calculates the power difference between two traces T1 the first trace operand and T2 the second trace operand Syntax CALCulate MATH PDIF Destination Trace T1 T2 Parameter Destination Trace TRACel TRACe2 TRACe3 or TRACe4 T2 Note The destination trace cannot be the same as the or T2 trace Example CALC MATH PDIF TRACT TRAC2 TRAC3 GW INSTEK REMOTE CONTROL CALCulate MATH LDIF Set Description Calculates the logarithmic difference between two traces T1 the first trace operand and T2 the second trace operand and assigns the designated reference level to the destination trace Syntax CALCulate MATH LDIF Destination Trace T
87. e OCBW BANDwidth BWIDth SSENSe OCBW PER Cent eene SENSe OCBW SPACe SENSe P1DB GAIN OFFSet METer RECording TIME METer RECording TIME STEP s SENSe POWeGr RF GAIN eee 60 SENSe SEMask BANDwidth BWIDth IN Tegration170 SENSe SEMask BANDwidth BWIDth RESoluti n eee HU d ENS SENSe SEMask BANDwidth BWIDth Solution ie nE NSe SEMask CARRier AUTO 3 ae NSe SEMask CARRier CPSD 008 NSe SEMask CARRier POWet 3EMask FREQuency SPAN SENSe SEMask GWLan MODulation m 15 5 E 5 1 SE SENSe SEMask NWLan CHANnel GW INSTEK REMOTE CONTROL BANDwidth BWIDth SENSe SEMask OF FSet lt n gt ADDition BANDwidth BWIDth RESolution 174 SENSe SEMask OF FSet lt n gt ADDition PRE Quenicy S TARE a cssccssesscs 176 SENSe SEMask OFFSet lt n gt ADDition FREQuency S TOP 2 iiiter ttis tetto itinere entes 176 SENSe SEMask OFFSet n ADDitio
88. e level Displays the reference level Attenuation Displays the vertical scale attenuation of the input signal Date Time Displays the date and time Marker Displays marker information information LXI icon This icon indicates the status of the LXI connection For details see page 27 20 GW INSTEK GETTING STARTED Function menu Soft menu keys associated with the F1 to F7 function keys to the right of the display Sweep Mode This icon displays the sweep mode as set by the Sweep Mode key Sweep settings Sweep icon that shows the sweep status Trace and detection settings Trace icon that shows the trace type and the detection mode used for each trace Blank Unassigned setting icons USB Trigger settings Trigger icon that shows the trigger status Pre amp settings Pre amplifier icon that shows the Pre amplifier status USB settings Displays the status of the USB A port Status Icons Displays the interface status power source status and alarm status etc See the Status Icon Overview on page 23 for a list of the status icons Frequency Displays the Start Center and Stop frequencies Bandwidth RBW VBW Span and Sweep settings settings 21 GW INSTEK GSP 9300 Programming Manual Entry Message This area is used to show system messages errors area and input values parameters Trace and Main display showing the input signals traces waveforms limit lines and marker positions Sweep pr
89. ee 122 DISPlay WINDow SPECtrogram eee 122 DISPlayWINDow SPLit NORMal ALTernate 123 DISPlayWINDow SPLit NORMal ACTive 123 DISPlayWINDow SPLitSPECtrogram DISPlay WINDoOw SPLit TOPO eese DISPlay WINDOow TOPO eerte DISPlay WINDow TOPO MARK PERCent 124 DISPlay WINDow TOPO DELT PERCent 124 DISPlay WINDow TRACecn MODBE 125 DISPlay WINDow TRACE lt n gt MODE MAXHOLD 125 DISPlay WINDow TRACe Y DLINe 125 DISPlayWINDow TRACe Y DLINe STATe 126 DISPlay WINDow TRACe Y SCALe AUTO 126 DISPlayWINDow TRACe Y SCALe NRLevel 126 DISPlay WINDow TRACe Y SCALe NRPosition 127 DISPlay WINDow TRACe Y SCALe PDIVision 127 DISPlay WINDow TRACe Y SCALe POSition 128 DISPlay WINDow TRACe Y SCALe RLEVel 128 DISPlay WINDow TRACe Y SCALe RLE Vel OFFSet 128 DISPlayWINDow TRACe Y SCALe SPACing 129 DISPlayWINDow TRACe Y SCALe STATe 129 DISPlay SPECtrogram DELTA INVerse TIME 130 CONTINUOUS ciis tet ettet rti 131 treten 131 SIN Put eire 132 INPutATTenuation AQ TQ erret 132 67 GW INSTEK GSP 9300 Programming Manual SINP tIMPedance iiti
90. eee 09 CALCulate OCBW POWer CALCu CALCu CALCu Tm CALCulate P1 DB GAIN RESult eese 11 CALCulate P1DB RESult eee 111 CALCulate PMETer POWetr 112 CALCu CALCu CALCu m CALCulate sSEM OFFSetcn RESult 13 CALCulate TOL DIFFerential eese 14 CALCulate TOIFREQuency DIFFerential 114 14 CALCulate TOI RESult er we 115 CAL Culate TOLSTA Ie eec ceres ettet 15 CONFig te MODE nisnin 16 SDISPlay BRIG tH SS os ccsccsccassess cepit genre exoasseszess 18 DISPlay ENABle aesaidiiaaenncnvanearaaaities 118 DISPlay DEMod WINDow TRACe X SCALe AUTO UM I 19 DISPlay DEMod WINDow TRACe X SCALe PTDL ViSiO its ancien ree arre 119 DISPlay DEMod WINDow TRACe X SCALe 120 GW INSTEK INITiate Commands INPut Commands REMOTE CONTROL DISPlay DEMod WINDow TRACe X SCALe SR VAIN 120 DISPlay DEMod WINDow TRACe Y SCALe AUTO PE E 120 DISPlay DEMod WINDow TRACe Y SCALe PID 16 ths E 121 DISPlay DEMod WIN Dow TRACe Y SCALe 121 DISPlay DEMod WIN Dow TRACe Y SCALe RV AUG sees tai 122 DISPlay WINDOw NORMal e
91. egree 2 Pollution refers to addition of foreign matter solid liquid or gaseous ionized gases that may produce a reduction of dielectric strength or surface resistivity Pollution degree 1 No pollution or only dry non conductive pollution occurs The pollution has no influence e Pollution degree 2 Normally only non conductive pollution occurs Occasionally however a temporary conductivity caused by condensation must be expected e Pollution degree 3 Conductive pollution occurs or dry non conductive pollution occurs which becomes conductive due to condensation which is expected In such conditions equipment is normally protected against exposure to direct sunlight precipitation and full wind pressure but neither temperature nor humidity is controlled GW INSTEK SAFETY INSTRUCTIONS Storage e Location Indoor enyironment e Temperature 20 C to 70 C e Humidity lt 90 Disposal Do not dispose this instrument as unsorted municipal waste Please use a separate collection facility or contact the supplier from which this instrument was purchased Please make sure discarded electrical waste is properly recycled to reduce environmental impact GW INSTEK GSP 9300 Programming Manual Power cord for the United Kingdom When using the instrument in the United Kingdom make sure the power cord meets the following safety instructions NOTE This lead appliance must only be wired by compet
92. em COMMunicate LANReset eee 197 SYSTem CO MMunicate SERial RECeive BAUD 97 SYSTem COMMunicate USB MODE SOY Sena DATE scent SSYSTem ERRor CLEar SSYSTem ERRor NEX T SSYSTem KLOCE SSYSTem PRBSet SSYSTem PRESetc TYPE SSYSTem PRESecUSER SAVE 5 SYSTem SHUTdown SYSTem TIME 5 SSYSTem VERSion HARDwate SSYSTem VERSion SOFTware eee STATus SSTATus OPERation CONDition eee 202 commands SSTATus OPERation ENABle eee 203 SSTATus OPERation EVENEt een 203 SSTATus OPERation NTRansition we 204 SSTATus OPERation PTRansition eee 204 SSTATus QUEStionable CONDition oceans 205 SSTATus QUEStionable wee 205 SSTATus QUEStionable EV ENt eee 206 SSTATus QUEStionable NTRansition 206 SSTATus QUEStionable PTRansition 207 SSTATus QUEStionable FREQuency CONDition 207 SSTATus QUEStionable FREQuency ENA Ble 208 SSTATus QUEStionable FREQuency EV ENt 208 SSTATus QUEStionable FREQuency NTRansition 208 STATus QUEStionable FREQuency PTRansition 209 STATus QUEStionable ACPLimit CONDition
93. ent Y axis units offset Carrier frequency offset in Hz 89 GW INSTEK GSP 9300 Programming Manual sinad Signal to noise and distortion ratio in dB Query Example CALC DEM FM RES CURR gt 9 840e 1 1 02e 2 1 12e 1 3 21e 1 1 61e 1 CALCulate DEMod FM RESult MINimum Description Returns the minimum recorded measurement results for FM demodulation as a comma separated string Query Syntax CALCulate DEMod FM RESult MINimum Return parameter lt deviation rate power offset sinad gt deviation Frequency deviation in Hz rate Modulation rate in Hz power Carrier power in the current Y axis units offset Carrier frequency offset in Hz sinad Signal to noise and distortion ratio in dB Query Example CALC DEM FM RES MIN gt 9 840e 1 1 02e 2 1 12e 1 3 21e 1 1 61e 1 CALCulate DEMod FM RESult MAXimum Description Returns the maximum recorded measurement results for FM demodulation as a comma separated string Query Syntax CALCulate DEMod FM RESult MAXimum Return parameter deviation rate power offset sinad deviation Frequency deviation in Hz rate Modulation rate in Hz power Carrier power in the current Y axis units offset Carrier frequency offset in Hz sinad Signal to noise and distortion ratio in dB Query Example CALC DEM FM RES MAX gt 9 840e 1 1 02e 2 1 12e 1 3 21e 1 1 61e 1 90 GW INSTEK REMOTE CONTROL Set CALC
94. ent persons WARNING THIS APPLIANCE MUST BE EARTHED IMPORTANT The wires in this lead are coloured in accordance with the following code Green Yellow Earth OF Blue Neutral Osage Brown Live Phase As the colours of the wires in main leads may not correspond with the coloured marking identified in your plug appliance proceed as follows The wire which is coloured Green amp Yellow must be connected to the Earth terminal marked with either the letter E the earth symbol 2 or coloured Green Green Yellow The wire which is coloured Blue must be connected to the terminal which is marked with the letter N or coloured Blue or Black The wire which is coloured Brown must be connected to the terminal marked with the letter L or P or coloured Brown or Red If in doubt consult the instructions provided with the equipment or contact the supplier This cable appliance should be protected by a suitably rated and approved HBC mains fuse refer to the rating information on the equipment and or user instructions for details As a guide a cable of 0 75mm should be protected by a 3A or 5A fuse Larger conductors would normally require 13A types depending on the connection method used Any exposed wiring from a cable plug or connection that is engaged in a live socket is extremely hazardous If a cable or plug is deemed hazardous turn off the mains power and remove the cable any fuses and fuse assemblies All hazar
95. erator is turned on Indicates that the tracking generator has been normalized Indicates that the wake up clock is turned on Indicates that a USB flash drive is inserted into the front panel and is recognized Indicates that a micro SD card is inserted into the front panel and is recognized GW INSTEK REMOTE CONTROL REMOTE CONTROL This chapter describes the basic configuration of IEEEA88 2 based remote control This chapter includes interface configuration a remote control overview as well as the control syntax and commands Interface Configuration 26 Command obire Fea asi 49 Status Registers trien Uhren ede eras doner ado 54 Command LIS i ou RR BIN MIE 64 25 GW INSTEK GSP 9300 Programming Manual Interface Configuration Configure to USB Remote Interface USB configuration PC side Type A host connector GSP side Rear panel Type B slave connector Speed 1 1 2 0 full speed high speed USB Class USB TMC USB T amp M class Panel operation 1 Connect the USB cable to the rear panel USB B port Press Ss More F 7 RmtInterface Config F1 USB Mode and toggle the USB mode to Device N Note It may take a few moments to switch USB modes Configure GPIB Interface To use GPIB the optional GPIB port must be installed Configure GPIB 1 26 En
96. et amplitude floor to auto OFF Turn autoset amplitude floor to manual ON Turn autoset amplitude floor to auto 149 GW INSTEK GSP 9300 Programming Manual Return parameter 0 Autoset amplitude floor is in manual 1 Autoset amplitude floor is in auto Example ASET AMPL AUTO 1 SENSe ASET RUN Set Description Activates the Autoset function Syntax SENSe ASET RUN Example ASET RUN Set SENSe ASET SPAN Description Sets or queries the Autoset span Syntax SENSe ASET SPAN freq Query Syntax SENSe ASET SPAN Parameter lt freq gt lt NRf gt Return parameter lt NR3 gt Hz Example ASET SPAN 2 0e 6 Set SENSe ASET SPAN AUTO Description Turns the Autoset span to auto or manual or queries its state Syntax SENSe ASET SPAN AUTO 1 Query Syntax SENSe ASET SPAN AUTO Parameter 0 Turn Autoset span to manual off 1 Turn Autoset span to automatic on OFF Turn Autoset span to manual off ON Turn Autoset span to automatic on Return parameter 0 Autoset span is set to manual off 1 Autoset span is set to automatic on 150 GW INSTEK REMOTE CONTROL Example ASET SPAN AUTO Set SENSe AVERage COUNt Description Sets or queries the number of traces that are used with the average function Syntax SENSe AVERage COUNt lt integer gt Query Syntax SENSe AVERage COUNt Parameter integer
97. ets or queries the state of the Harmonics function Syntax CALCulate HARMonic STATe ON OFF Query Syntax CALCulate HARMonic STATe Parameter OFF Turn Harmonic measurement off ON Turn Harmonic measurement on Return parameter 0 Harmonic measurement is off 1 Harmonic measurement is on Example CALC HARM STAT ON Set CALCulate JITTer STATe Description Sets or queries the state of the Jitter Analysis function Syntax CALCulate JITTer STATe ONJOFF 1 0 Query Syntax CALCulate JITTer STATe GW INSTEK REMOTE CONTROL Parameter 0 Turn Jitter Analysis off 1 Turn Jitter Analysis on OFF Turn Jitter Analysis off ON Turn Jitter Analysis on Return parameter 0 Jitter Analysis is off 1 Jitter Analysis is on Example CALCulate JITTer STATe 1 CALCulate ITTer CARRier POWer Description Returns the carrier power in the current Y axis units Query Syntax CALCulate JITTer CARRier POWer Return parameter lt NR3 gt In the current Y axis units Query Example CALC JITT CARR POW gt 5 237e 01 CALCulate ITTer PHASe Description Returns the carrier phase jitter in radians Query Syntax CALCulate JITTer PHASe Return parameter lt NR3 gt Rad Query Example CALC JITT PHAS gt 1 5307e 01 CALCulate ITTer TIME Description Returns the carrier jitter time in seconds Query Syntax CALCulate JITTer TIM E Return parameter lt NR3 gt Seconds Query E
98. f test The GSP 9300 does not support performing a selftest and thus will always return 0 for this query 76 GW INSTEK REMOTE CONTROL Query Syntax TST Return parameter 0 Returns 0 WAI Set Description Prevents any other commands or queries from being executed until all outstanding commands have completed Syntax WAI CALCulate Commands CALCulate ACPR ACHannel lt n gt HLIMit FAIL 79 CALCulate ACPR ACHannel lt n gt LLIMit FAIL 80 CALCulate ACPR ACHannelcn LOWet 80 CALCulate ACPR ACHannel n2 UPPet 80 CALCulate ACPR ACHannel lt n gt STAT 81 CALCulate ACPR CHANneLEHLIMitF AIL 81 CALCulate ACPR CHANneLELLIMiIitFAIL2 82 CALCulate ACPR CHPowet eese CALCulate ACPR STATe CALCulate BESK STATe eee CALCulate BFSK RESTart CALCulate BESK RESult CALCulate CNR RESult CALCu CALCu CALCu CALCulate CTB RESult eese 85 GATGalate CEB S 85 CALCulate CTB RESTatt necnon 86 CALCulate DELTamarker lt n gt PAIR SPAN 86 CALCulate DELTamarker lt n gt PAIR CENTet 86 CALCulate DELTamarker lt n gt X eee 86
99. for SEM measurements or queries its state Syntax SENSe SEMask BAN Dwidth BW1Dth RESolution AUTO OFF ON O 1 GW INSTEK REMOTE CONTROL Query Syntax SENSe SEMask BAN Dwidth BWIDth RESolution AUTO Parameter 0 Turn RBW to manual off 1 Turn RBW to auto on OFF Turn RBW to manual off ON Turn RBW to auto on Return parameter 0 RBW is set to manual 1 RBW is set to automatic Example SEM BAND AUTO OFF Set SENSe SEMask CARRier AUTO Description Turns the PSDRef or TotalPwrRef modes to auto on or manual off for SEM measurements or queries their state Syntax SENSe SEMask CARRier AUTO OFF ON 0 1 Query Syntax SENSe SEMask CARRier AUTO Parameter 0 Turn PSDRef TotalPwrRef to manual off Turn PSDRef TotalPwrRef to auto on OFF Turn PSDRef TotalPwrRef to manual off ON Turn PSDRef TotalPwrRef to auto on Return parameter 0 PSDRef TotalPwrRef is set to manual PSDRef TotalPwrRef is set to automatic Example SEM CARR AUTO OFF Set SENSe SEMask CARRier CPSD Description Sets or queries the value of the PSDRef for SEM measurements Syntax SENSe SEMask CARRier CPSD lt NR3 gt Query Syntax SENSe SEMask CARRier CPSD 171 GW INSTEK GSP 9300 Programming Manual Parameter lt NR3 gt PSD ref unit dBm Hz Return parameter Example SEM CARR CPSD 20 Set SENSe SEMask CARRier POWer De
100. g measurements that have a channel space setting Syntax SENSe CHANnel SPACe UP Example CHAN SPAC UP Set SENSe CNR CHANnel SPACe Description Sets or queries the channel space bandwidth for CNR measurements Syntax SENSe CNR CHANnel SPACe freq Query Syntax SENSe CNR CHANnel SPACe Parameter lt freq gt lt NRf gt Return parameter lt NR3 gt Hz Example CNR CHAN SPAC 6 0e 6 SENSe CNR DELTamarker MODE Set Description Turns the CNR Noise Marking function to Min AUTO or AMarker MANual Syntax SENSe CNR DELTamarker MODE AUTO MANual Parameter AUTO Sets the Noise Marking to Min AMarker Sets the Noise Marking to AMarker Example CNR DELT MODE AUTO GW INSTEK REMOTE CONTROL Set SENSe CORRection CSET lt n gt DATA Description As a command sets an offset for a certain frequency for a selected correction set As a query returns the data contents for the selected correction set as lt csv data gt The data will be arranged as pt 1 freq pt 1 offset pt 2 freq pt 2 offset Syntax SENSe CORRection CSET lt n gt DATA lt freq gt lt offset gt Query syntax SENSe CORRection CSET lt n gt DATA Parameter lt freq gt lt NRf gt Hz lt offset gt lt NRf gt dB lt n gt lt NR1 gt correction set number Return parameter CSV data pt freq pt 1 offset pt n freq pt n offset Example CORR CSET1 DATA 2e 6 30 Set SENSe CORRection CSET lt n gt STATe
101. gories and their requirements as follows The instrument falls under category e Measurement category IV is for measurement performed at the source of low voltage installation e Measurement category is for measurement performed in the building installation e Measurement category II is for measurement performed on the circuits directly connected to the low voltage installation e Measurement category is for measurements performed on circuits not directly connected to Mains GW INSTEK GSP 9300 Programming Manual Power Supply e AC Input voltage range 100V 240V e Frequency 50 60Hz WARNING To avoid electrical shock connect the protective grounding conductor of the AC power cord to an earth ground Battery e Rating 10 8V 6 cell Li ion battery Turn off the power and remove the power cord CAUTION before installing or removing the battery Cleaning e Disconnect the power cord before cleaning e Usea soft cloth dampened in a solution of mild detergent and water Do not spray any liquid e Do not use chemicals containing harsh material such as benzene toluene xylene and acetone Operation e Location Indoor no direct sunlight dust free Environment almost non conductive pollution Note below Temperature 5 C to 45 C e Humidity lt 90 Pollution Degree EN 61010 1 2010 specifies the pollution degrees and their requirements as follows The instrument falls under d
102. he additional requirements of the selected 3GPP SEM test Query syntax SENSe SEMask OFFSet lt n gt ADDition STARt ABSolute Parameter lt n gt Offset 1 to 5 Return parameter lt NR3 gt Amplitude at start frequency Example SEM OFFST ADD STAR ABS gt 1 5e 1 SENSe SEMask OFFSet lt n gt ADDition STOP ABSolute Description Returns the Stop amplitude dBm of the Absolute Mask for the selected offset for the additional requirements of the selected 3GPP SEM test Query syntax SENSe SEMask OFFSet lt n gt ADDition STOP ABSolute Parameter lt n gt Offset 1 to 5 Return parameter lt NR3 gt Amplitude at stop frequency Example SEM OFFST ADD STOP ABS gt 1 5e 1 SENSe SEMask OFFSet lt n gt BANDwidth Set BWIDth RESolution Description Sets or queries the resolution bandwidth of the selected offset 177 GW INSTEK GSP 9300 Programming Manual Syntax SENSe SEMask OFFSet lt n gt BAN Dwidth BWIDth RESolution freq Query Syntax SENSe SEMask OFFSet lt n gt BAN Dwidth BWIDth RESolution Parameter lt freq gt lt NR3 gt Hz Return parameter lt n gt lt NR1 gt offset 1 5 Example SEM OFFS1 BAND 3 0e 3 SEN Se SEMask OF FSet lt n gt BAN Dwidth B WIDth RESolution AUTO Description Turns the resolution bandwidth for the selected channel to manual or automatic mode or queries its state Syntax SENSe SEMask OFFSet
103. ine data from a file to the internal memory Syntax MMEMory LOAD LIMit lim num src file name Parameter lim num NRI limit line 1 5 src file name XXX lim Example MMEM LOAD LIM 2 test lim MMEMory LOAD PMETer Set Description Loads power meter data from a file to the internal memory Syntax MMEMory LOAD PMETer src file name Parameter src file name XXX pmet Example MMEM LOAD PMET test pmet MMEMory LOAD SEQuence Set Description Loads sequence data from a file to the internal memory 137 GW INSTEK GSP 9300 Programming Manual Syntax MMEMory LOAD SEQuence seq num src file name Parameter seq num lt NR1 gt sequence number 1 5 src file name XXX seq Example MMEM LOAD SEQ 2 test seq MMEMory LOAD STATe Set Description Loads the instrument state from a file to the internal memory Syntax MMEMory LOAD STATe src file name Parameter src file name XXX stat Example MMEM LOAD STAT test stat MMEMory LOAD TRACe Set Description Loads trace data from a file to the internal memory Syntax MMEMory LOAD TRACe trace name src file name Parameter trace name gt NRI 1 4 src file name XXX tra Example MMEM LOAD TRAC 2 test tra MMEMory MOVE Set Description Moves a designated file from the current file directory to the destination directory The file can be renamed after it is moved Syntax MMEMor
104. ion Sets or queries the Questionable Status TOI Limit Event Enable register Syntax STATus QUEStionable TOILimit ENABle integer Query Syntax STATus QUEStionable TOILimit ENABle Return parameter Bit Bit Weight Description 0 1 314 lower fail 1 2 34 upper fail Example SSTATE QUES TOIL ENAB 1 STATus QUEStionable TOlLimit EVENt Description Returns the bit weight of the Questionable Status TOI Limit Event register Reading this register will clear the event register Query Syntax STATus QUEStionable TOILimit EVENt Return parameter Bit Bit Weight Description 0 1 314 lower fail 1 2 31 4 upper fail Example STATEQUES TOIL gt l STATus QUEStionable TOILimit Set NTRansition Description Sets or queries the bit weight of the NTR filter for the Questionable Status TOI Limit register Syntax STATus QUEStionable TOILimit NTRansition lt integer gt Query Syntax STATus QUEStionable TOILimit NTRansition GW INSTEK REMOTE CONTROL Return parameter Bit Bit Weight Description 0 1 314 lower fail 1 2 3 upper fail Example STAT QUES TOIL NTR 1 STATus QUEStionable TOILimit Set PTRansition Description Sets or queries the bit weight of the PTR filter for the Questionable Status TOI Limit register Syntax STATus QUEStionable TOILimit PTRansition lt integer gt Query Syntax STATus QUEStionable TOILimit PTRansition Return parameter Bit Bit Weight Descrip
105. ion Turns the SEM measurement on off or queries its state Syntax CALCulate SEM STATe ON OFF 1 0 Query Syntax CALCulate SEM STATe Parameter 0 Turns SEM off 1 Turns SEM on OFF Turns SEM off ON Turns SEM on Return parameter 0 SEM is off 1 SEM is on Example CALC SEM STAT ON CALCulate SEM OFFSet n RESult Description Returns the start stop frequencies as well as the pass fail limits and judgements for the chosen offset Query syntax CALCulate SEM OFFSet lt n gt RESult Parameter lt n gt Offset number 1 5 Return parameter lt start freq gt Start frequency of the selected channel lt low dBm gt Lower dBm measurement low p f gt Lower pass fail limit judgment 0 pass 1 fail stop freq Stop frequency of the selected channel upp dBm Upper dBm measurement 113 GW INSTEK GSP 9300 Programming Manual lt upp p f gt Upper pass fail limit judgment 0 pass 1 fail Example CALC SEM OFFST RES gt 9e 7 7 9e 1 0 1 7e 7 6 9e 1 0 CALCulate TOI DIFFerential Query Description Returns the third order intermodulation distortion Query syntax CALCulate TOI DIFFerential Return parameter lt base lower gt lt NR3 gt dBc lt base upper gt lt NR3 gt dBc lt 3 order lower NR3 dBc lt 3 order upper lt NR3 gt dBc Example CALC TOI DIFF gt 0 0e 0 1 67e 1 1 09e 1 6 61e 0 CALCulate TOI FREQuency DIFFerential Description Returns the
106. isabled ON ACPR is enabled GW INSTEK REMOTE CONTROL Return parameter 0 ACPR is disabled 1 ACPR is enabled Query Example CALC ACPR STAT gt Set CALCulate BFSK STATe Description Sets or queries the state of the BFSK measurement function Syntax CALCulate BFSK STATe OFF ON Query Syntax CALCulate BFSK STATe Parameter OFF BFSK is disabled ON BFSK is enabled Return parameter 0 BFSK is disabled BFSK is enabled Query Example CALC BFSK STAT gt CALCulate BFSK RESTart Set Description Restarts the BFSK measurement Syntax CALC BFSK REST CALCulate BFSK RESult Description Returns the BFSK measurement result Query Syntax CALCulate BFSK RESult Return parameter lt freq deviation gt lt carrier offset gt lt freq deviation gt Frequency deviation in NRf format lt carrier offset gt Carrier offset in NRf format Query Example CALC BFSK RES gt 4 416666667e 04 4 416666667e 04 83 GW INSTEK GSP 9300 Programming Manual CALCulate CNR RESult Query Description Returns the CNR measurement result in dB Query Syntax CALCulate CNR RESult Return parameter lt NR3 gt CNR measurement in dB Query Example CALC CNR RES gt 4 959e 01 Set CALCulate CNR STATe Description Sets or queries the state of the CNR measurement function Syntax CALCulate CNR STATe ON OFF 1 0 Query Syntax CALC
107. it sum of the Standard Event Status Enable register ESR Description Queries the Standard Event Status register The Event Status register is cleared after it is read Query Syntax ESR Return parameter lt NR1 gt Returns the bit sum of the Standard Event Status register and clears the register Set OPC Description The command sets the OPC bit bitO of the Standard Event Status Register when all current commands have been processed The OPC Query returns 1 when all the outstanding commands have completed 75 GW INSTEK GSP 9300 Programming Manual Syntax OPC Query Syntax OPC Return parameter 1 Returns 1 when all the outstanding commands have completed RST Set Description RST will perform a factory reset Syntax RST Set SRE Description Sets or queries the Service Request Enable register The Service Request Enable register determines which registers of the Status Byte register are able to generate service requests Syntax SRE NR1 Query Syntax SRE Parameter NRI 0 255 Return parameter NRI Returns the bit sum of the Service Request Enable register STB Query Description Queries the bit sum of the Status Byte register with MSS Master summary Status Query Syntax STB Return parameter NR1 Returns the bit sum of the Status Byte register with the MSS bit bit 6 TST Query Description Returns the result of a sel
108. k NWLan CHANnel Set BANDwidth BWIDth Description Sets the channel bandwidth for the 802 11n SEM measurement Only 20MHz or 40MHz can be used Syntax SENSe SEMask NWLan CHANnel Dwidth BWIDth freq Parameter lt freq gt lt NRf gt 20 MHz or 40MHz Return parameter lt NR3 gt Example SEM NWL CHAN BAND 20 MHZ 173 GW INSTEK GSP 9300 Programming Manual SENSe SEMask OFFSet lt n gt ADDition Dwidth BWIDth RESolution Description Returns the RBW of the selected offset for the additional requirements of the selected 3GPP SEM test Query syntax SENSe SEMask OFFSet lt n gt ADDition BANDwidth BWIDth RESolution 3GPP FDD BS For operation in bands IV V X XIV and Additional XXV additional requirements listed below apply in Requirements addition to the minimum requirements listed above For 3GPP FDD UE A means 1 B means 2 UM P138 174 GW INSTEK REMOTE CONTROL Unit MHz Additional RBW Bands Il IV X 2 5 lt A lt 3 5 15dBm 30kHz 3 5 lt B lt Afmax 13dBm Unit MHz Additional RBW Bands V 2 5 lt A lt 3 5 15dBm 30kHz 3 5 lt B lt Afmax 13dBm 100kHz Unit MHz Additional RBW Bands 3 5 lt B lt Afmax 13dBm 100kHz 3GPP FDD UE Additional requirements for 3GPP FDD UE For 3GPP Additional FDD BS Requirements A means 1 B means 2 UM P137 Unit MHz AdditionalBl
109. l high fail 1 2 Main channel low fail 2 4 Adj1 high fail 3 8 Adj1 low fail 4 16 Adj2 high fail 5 32 Adj2 low fail 6 64 Adj3 high fail 7 128 Adj3 low fail Example STAT QUES ACPL NTR 3 STATus QUEStionable ACPLimit Set PTRansition Description Sets or queries the bit weight of the PTR filter for the Questionable Status ACP Limit register 211 GW INSTEK GSP 9300 Programming Manual Syntax STATus QUEStionable ACPLimit PTRansition integer Query Syntax STATus QUEStionable ACPLimit PTRansition Return parameter Bit Bit Weight Description 0 1 Main channel high fail 1 2 Main channel low fail 2 4 Adj1 high fail 3 Adj1 low fail 4 16 Adj2 high fail 5 32 Adj2 low fail 6 64 Adj3 high fail 7 128 Adj3 low fail Example STAT QUES ACPL PTR 3 STATus QUEStionable SEMLimit CONDition Query Description Returns the bit weight of the Questionable Status SEM Limit Condition register Query Syntax STATus QUEStionable SEMLimit CONDition Return parameter Bit Bit Weight Description 0 1 Offset 1 Upper fail 1 2 Offset 1 Lower fail 2 4 Offset 2 Upper fail 3 8 Offset 2 Lower fail 4 16 Offset 3 Upper fail 5 32 Offset 3 Lower fail 6 64 Offset 4 Upper fail 7 128 Offset 4 Lower fail 8 256 Offset 5 Upper fail 9 512 Offset 5 Lower fail Example STAT QUES SEML COND gt 3 212 GW INSTEK REMOTE CONTROL Set STATus QUEStionable SEMLimit ENABle Description Sets or
110. l is disabled The selected channel is enabled Query Example CALC ACPR ACH1 STAT gt CALCulate ACPR CHANnel HLIMit FAIL Description Returns the ACPR upper limit pass fail judgment for the main channel A pass indicates that every trace point in the main channel is lower than or equal to the uppder limit Query Syntax CALCulate ACPR CHANnel HLIMit FAIL Return parameter 0 lt boolean gt Pass 1 lt boolean gt Fail Query Example CALC ACPR CHAN HLIM FAIL 20 81 GW INSTEK GSP 9300 Programming Manual CALCulate ACPR CHANnel LLI Mit FAIL Description Returns the ACPR lower limit pass fail judgment for the main channel A pass indicates that every trace point in the main channel is higher than or equal to the lower limit Query Syntax CALCulate ACPR CHANnel LLIMit FAIL Return parameter 0 lt boolean gt Pass 1 lt boolean gt Fail Query Example CALC ACPR CHAN LLIM FAIL gt 0 CALCulate ACPR CHPower Query Description Returns the ACPR main channel power in the current chosen unit Query Syntax CALCulate ACPR CHPower Return parameter lt NR3 gt Power Query Example CALC ACPR CHP gt 1 028e 02 Set CALCulate ACPR STATe Description Sets or queries the state of the ACPR measurement function Syntax CALCulate ACPR STATe OFF ONJO 1 Query Syntax CALCulate ACPR STATe Parameter 0 ACPR is disabled 1 ACPR is enabled OFF ACPR is d
111. l reset the register to 0 The Service Request Enable Register controls which bits in the Status Byte Register are able to generate service requests Bit Summary Bit Weight Description 2 4 Error Event Queue Summary bit This bit is set when there is a message in the error queue 3 Questionable Status Summary Bit This is the summary bit for the Questionable Status Register 4 16 MAV This bit is set when there is a message in the output queue 57 GW INSTEK 5 32 6 64 7 128 GSP 9300 Programming Manual ESB This is the summary bit for the Standard Event Register MSS RQS The MSS bit is the summary bit for the Service Request Enable Register The RQS bit is set to 1 when the MSS bit is set to 1 Operation Status Summary Bit This is the summary bit for the Operation Status Register Standard Event Status Register ESR Overview The Standard Event Status Register Group indicates if any errors have occurred or fail limits tripped Reading this register will clear the register Bit Summary Bit Weight Description 2 4 3 8 4 16 5 32 6 64 7 28 58 Query Error When a query error has occurred this bit is set to 1 Device Specific Error When a device dependent error has occurred this bit is set to 1 Execution Error When an execution error has occurred this bit is set to 1 Command Error When a command error has occurred this bit is set to 1 User Request When a panel key is pressed
112. litude for NdB bandwidth measurements Syntax SENSe NDB BAN Dwidth BWIDth rel amp Query Syntax _ SENSe NDB BANDwidth BWIDth Parameter rel amp lt NRf gt Return parameter lt NR3 gt dB Example NDB BAND 3 dB Set SENSe OCBW BANDwidth BWIDth Description Sets or queries the OCBW bandwidth for OCBW measurements Syntax SENSe OCBW BANDwidth BWIDth freq Query Syntax SENSe OCBW BAN Dwidth BWIDth Parameter lt freq gt lt NRf gt Return parameter lt NR3 gt Hz Example OCBW BAND 4 5 6 Set SENSe OCBW PERCent Description Sets or queries the OCBW percentage OCBW parameter 165 GW INSTEK GSP 9300 Programming Manual Syntax SENSe OCBW PERCent lt integer gt Query Syntax SENSe OCBW PERCent Parameter integer lt NR1 gt 0 100 Return parameter Example OCBW PERC 90 Set SENSe 0CBW SPACe Description Sets or queries the OCBW channel space for OCBW measurements Syntax SENSe OCBW SPACe freq Query Syntax SENSe OCBW SPACe Parameter lt freq gt lt NRf gt Return parameter lt NR3 gt Example OCBW SPAC 6e 7 Set SENSe P1 DB AVERage COUNt Description Sets or queries the number of samples used for the average function in the P1dB function Syntax SENSe PTDB AVERage COUNt Query Syntax SENSe P1 DB AVERage COUNt Parameter NRI The average number Return parameter lt NR1 gt Returns the average number
113. ly Attributes VISA Properties 4 GW INSTEK GSP 9300 Programming Manual 7 Click on Configuration 8 Click on the GPIB Settings tab and confirm that the GPIB settings are correct 9 Click on the I O Settings tab 10 Make sure the Enable Termination Character check box is checked and the terminal character is n Value xA 11 Click Apply Changes crres tNSTR Ex GPIB Settings LO Settings View Attributes Standard Settings Termination Methods Timeout ms 3000 Refresh Apply Changes 12 Click on Input Output 13 Click on the Basic IO tab 42 GW INSTEK REMOTE CONTROL 14 Enter IDN in the Select or Enter Command drop down box 15 Click Query 16 The IDN query will return the Manufacturer model name serial number and firmware version in the dialog box GWINSTEK GSP9300 ENXXXXXX TX X X X 13 crrea 3 1NsTR Read Status Byte View mixed ASCl hexadecimal 5 Clear Buffer 43 GW INSTEK GSP 9300 Programming Manual USB Function Check Background To test the USB functionality National Instruments Measurement and Automation Explorer can be used This program is available on the NI website www ni com via a search for the VISA Run time Engine page or downloads at the following URL http www ni com visa In addition the IVI driver for the GSP 9300 must also be d
114. ment amp Automation Explorer Loading plug ins Version 5 5 1999 2013 National Instruments All rights reserved Select the GSP 9300 device that now appears in the System gt Devices and Interfaces gt GSP9300 USBX node Click on the VISA Properties tab on the bottom Click Open Visa Test Panel Eile Edit View Tools Help 4 El My System Refresh Bh Open VISA Test Panel 4 Devices and Interfaces ASRLI INSTR COM1 GSP930A USB0 0x2184 0x001B EN161912 INSTR Measurement amp 5 mation Explorer 89 ASRL2 COM2 Settings ASRLI LPT amp GSP9300 USBO0 0x2184 0 Name 4 Network Devices Vendi GWINSTEK amp Software Vas ws fij IVI Drivers Model GSP9300 88 Remote Systems Serial Number EN161912 Status Present VISA Resource Name USB0 0x2184 0x001B EN1619 I i t E settings S General GW INSTEK REMOTE CONTROL 7 Click on the I O Settings tab 8 Make sure the Enable Termination Character check box is checked and the terminal character is n Value xA 9 Click Apply Changes 48 u520 012184 0x0018 EN161912 INSTR meu Refresh Apply Changes 10 Click on Input Output 11 Click on the Basic IO tab 12 Enter IDN in the Select or Enter Command drop down box 13 Click Query 14 The IDN query will return the Manufacturer model name serial number and firmware version in the dialog box GWINSTEK GSP9300 ENDOO
115. n Example CALC TOI STAT ON 115 GW INSTEK GSP 9300 Programming Manual CONFigure Commands CONEig ite MODE tette 116 Set CONFigure MODE Description Sets or queries the operating mode spectrum or power meter Syntax CONFigure MODE SA PMETer Query Syntax CONFigure MODE Parameter SA Spectrum mode Return parameter lt PMETer gt Power meter mode Example CONF MODE SA 116 GW INSTEK REMOTE CONTROL DISPlay Commands DISPhy BRIGhtneSS L18 DISPIag ENAABle iet 118 DISPlay DEMod WINDow TRACe X SCALe 119 DISPlay DEMod WINDow TRACe X SCALe POLVI Oir e 119 DISPlay DEMod WINDow TRACe X SCALe hieu 120 DISPlay DEMod WINDow TRACe X SCALe nian 120 DISPlay DEMod WINDow TRACe Y SCALe A AAN 120 DISPlay DEMod WINDow TRACe Y SCALe PDEVISIOB eee 121 DISPlay DEMod WINDow TRACe Y SCALe RPOSItOB eiui ate d p iter HOOP TREE 121 DISPlay DEMod WINDow TRACe Y SCALe RY Ae sts ii sireisas r REE 122 DISPlay WINDow NORMal eee 122 DISPlay WINDow SPECtrogram eee 122 DISPlay WINDow SPLit NORMal ALTernate 123 DISPlay WINDow SPLit NORMal ACTive 123 DISPlay WINDow SPLit SPECtrogram
116. n STAREADBSOlUt amp satt EG ae racc icri puer AR 177 SENSe SEMask OFFSet lt n gt ADDition STOP A BS Olt za incita cd iie ese ioter 177 SENSe SEMask OFFSet lt n gt BANDwidth BWIDth RBSolution toners 177 SENSe SEMask OFFSet lt n gt BANDwidth BWIDth RESolution AUTO ete oett tortis 178 SENSe SEMask OFFSet n FREQuency STARt 178 SENSe SEMask OFFSet n FREQuency STOP 179 SENSe SEMask OF FSet lt n gt STARt ABSolute 179 SENSe SEMask OF FSet lt n gt STARt RELative 179 5 5 6 5 180 SENSe SEMask OF FSet lt n gt STOP ABSolute 180 SENSe SEMask OF FSet lt n gt STOP ABSolute UR 181 SENSe SEMask OFFSet n STOP RELative 181 SENSe SEMask OF FSet lt n gt STOP RELative COUP eiiiai SENSe SEMask OF FSet lt n gt TEST ss SENSE teet tnter 5 5 5 6 SENSe SEMask W3GPP DUPLex TYPE SENSe SEMask W3GPP FDD ADDition LIMit 184 SENSe SEMask W3GPP FDD ADDition MOPOWE E iai Ss Satie E pata SENSe SEMask W3GPP FDD MO Power SENSe SEMask W3GPP FDD TRANsmit MODE 185 SENSe SEMask W3GPP TDD CHIP RATE 185 SENSe SEMask W3GPP TDD MOPowet 186 SENSe SEMask W3GPP TDD TRANsmit MODE 1
117. n gt LLIMit Description Sets or queries the low limit for the selected adjacent channel Used with ACPR measurement Syntax SENSe ACPR ACHannel lt n gt LLIMit lt ampl gt Query Syntax SENSe ACPR ACHannel lt n gt LLIMit Parameter lt ampl gt lt NRf3 gt power or voltage Return parameter lt NR3 gt Example ACPR ACHT LLIM 5 0e 1 Set SENSe ACPR ACHannel lt n gt OFFSet Description Sets or queries the adjacent channel offset for the selected adjacent channel Used with ACPR measurement Syntax SENSe ACPR ACHannel lt n gt OF FSet freq Query Syntax SENSe ACPR ACHannel lt n gt OFFSet Parameter lt freq gt lt NRf gt Return parameter lt NR3 gt Hz Example ACPR ACHT OFFSet 2 0e 6 Set SENSe ACPR BAN Dwidth BWIDth Description Sets or queries the main channel bandwidth for ACPR measurements Syntax SENSe ACPR BAN Dwidth BWIDth freq Query Syntax SENSe ACPR BAN Dwidth BWIDth Parameter lt freq gt lt NRf gt Return parameter lt NR3 gt Hz Example ACPR BAND 2 0e 6 147 GW INSTEK GSP 9300 Programming Manual Set SENSe ACPR HLIMit Description Sets or queries the high limit for the main channel Used with ACPR measurement Syntax SENSe ACPR HLIMit lt ampl gt Query Syntax SENSe ACPR HLIMit Parameter lt ampl gt lt NRf gt power or voltage Return parameter lt NR3 gt Example ACPR H
118. nce DEMod LEVel TRIGger SEQuence DEMOd MODSE TRIGger SEQuence DEMod SLOPe TRIGger SEQuence DEMod SOURce T TRIGger SEQuence DEMod TIME STAREt 222 TRIGger SEQuence DEMod TIME STOP 222 E TRIGger SEQuence EXTernal SLOPe 5 TRIGger SEQuence PMETer SOURCe 223 TRIGger SEQuence SOURce m TRIGger SEQuence VIDeo FREQuency 224 TRIGger SEQuence VIDeo LEVel 224 TRIGger SEQuence VIDeo SLOPe 225 TRIGger SEQuence DELay Description Sets the trigger delay time in seconds Syntax TRIGger SEQuence DELay lt time gt Query Syntax TRIGger SEQuence DELay Parameter time Delay time in seconds Return parameter Example TRIG DEL 1 0e 2 Set TRIGger SEQuence DEMod DELay Description Sets the AF trigger delay time in seconds for AM FM demodulation Syntax TRIGger SEQuence DEMod DELay lt time gt Query Syntax TRIGger SEQuence DEMod DELay 220 GW INSTEK REMOTE CONTROL Parameter lt time gt Delay time in seconds Return parameter Example TRIG DEM DEL 1 0 ms Set TRIGger SEQuence DEMod LEVel Description Sets the trigger level for A
119. ncy OFF Set Parameter lt freq gt lt NRf gt Return parameter lt NR3 gt Example FREQ OFFS 1 0e 6 Set SENSe FREQuency SPAN Description Sets or queries the span settings Syntax SENSe FREQuency SPAN lt freq gt Query Syntax SENSe FREQuency SPAN Parameter lt freq gt Return parameter lt NR3 gt Hz Example FREQ SPAN 2 0e 9 SENSe FREQuency SPAN FULL Set Description Set the span to Full Span Syntax SENSe FREQuency SPAN FULL Example FREQ SPAN FULL SENSe FREQuency SPAN PREVious Set Description Set the span to the previous span setting 162 GW INSTEK REMOTE CONTROL Syntax SENSe FREQuency SPAN PREVious Example FREQ SPAN PREV Set SENSe FREQuency STARt Description Sets or queries the start frequency Syntax SENSe FREQuency STARt lt freq gt Query Syntax SENSe FREQuency STARt Parameter lt freq gt lt NRf gt Return parameter lt NR3 gt Hz Example FREQ STAR 0 Set SENSe FREQuency STOP Description Sets or queries the stop frequency Syntax SENSe FREQuency STOP lt freq gt Query Syntax SENSe FREQuency STOP Parameter lt freq gt lt NRf gt Return parameter lt NR3 gt Hz Example FREQ STOP 1 0e 6 SENSe HARMonic FUNDamental Set FREQuency Description Sets or queries the harmonic frequency Syntax SENSe HARMonic FUNDamental FREQuency freq Query Syntax SEN
120. ng Manual UNIT Commands UNIT PMETer POWet iiid sardiini 226 UNTE POWef onenen eee ae A ENEE 226 Set UNIT PMETer POWer Description Sets the amplitude unit used for the Power Meter mode Syntax UNIT PMETer POWer DBM MW Query Syntax UNIT PMETer POWer Parameter DBM Decibels Return parameter MW Milliwatts Example UNIT PMET POW DBM Set UNIT POWer Description Sets the amplitude unit used for the Spectrum mode Syntax UNIT POWer DBM DBMV DBUV W V Query Syntax UNIT POWer Parameter DBM Decibels Return parameter DBMV decibels relative to one millivolt DBUV decibels relative to one microvolt W Watt V Volt Example UNIT DOW DBM GW INSTEK APPENDIX DIX ASCII to Binary Coded Decimal Table Background The PIXel query uses binary coded decimal notation when returning the value of each pixel that is displayed See page 218 for details Decimal Binary ASCII Decimal Binary ASCII 0 00000000 NUL 64 01000000 9 1 0000000 SOH 65 01000001 A 2 00000010 STX 66 01000010 B 3 00000011 ETX 67 01000011 C 4 00000100 EOT 68 01000100 D 5 00000101 ENQ 69 01000101 E 6 00000110 ACK 70 01000110 F 7 00000111 BEL 71 01000111 G 8 00001000 BS 72 01001000 H 9 00001001 HT 73 01001001 I 10 00001010 LF 74 01001010 J 11 00001011 VT 75 01001011 K 12 00001100 FF 76 01001100 L 13 00001101 CR 77 01001101 M 14 00001110 SO 78 01001110
121. ng Numeric DC power Micro SD generator Enter and supply port output BK SP keys LCD display 800x600 color LCD display The display shows the soft keys for the current function frequency amplitude and marker information Function keys E E The F1 to F7 function keys directly correspond to the soft keys on the right hand side of display Main keys Sets the center frequency start frequency stop frequency center frequency step and frequency offset values 12 GW INSTEK GETTING STARTED Sets the span with options for full span zero span and last span Span Sets the amplitude reference level attenuation pre amplifier controls scale and other options for attenuation and scale Amplitude Automatically searches the peak signal with maximum amplitude and displays it with appropriate horizontal and vertical scales Sets the resolution bandwidth video bandwidth average type and turns the EMI filter on off Control keys BW Avg Sets the sweep time and gate time Toggles the Sweep Control between Fast and Normal mode Accesses measurement options such as ACPR OCBW demodulation measurements SEM TOI 2FSK phase jitter and other advanced measurements EMC Dedicated EMI testing and setup Pretest menu Sets traces and trace related functions Trace Limit Sets and tests Pass Fail limit lines Line 13 GW INSTEK GSP 9300 Programming Manual The Display key c
122. nuous or single mode or queries its state Syntax INITiate CONTinuous OFF ONJO 1 Query Syntax INITiate CONTinuous Parameter 0 single 1 continuos OFF single ON continuos Return parameter 0 single 1 continuos Example INITiate IMMediate Set Description Initiates an immediate single sweep then stops the sweep Syntax INITiate IM Mediate Example INIT 131 GW INSTEK GSP 9300 Programming Manual INPut Commands 132 3 132 INPut MPedance a x STIN Plats OB PS 1 Set INPut ATTenuation Description Sets or queries the input attenuation Syntax INPut ATTenuation lt integer gt Query Syntax INPut ATTenuation Parameter integer 0 to 50 Return parameter Example INP ATT 10 dB Set INPut ATTenuation AUTO Description Sets or queries whether the automatic input attenuation is on off Syntax INPut ATTenuation AUTO OFF ON 0 1 Query Syntax INPut ATTenuation AUTO Parameter 0 Turn automatic input attenuation off Turn automatic input attenuation on OFF Turn automatic input attenuation off ON Turn automatic input attenuation on Return parameter 0 Automatic input attenuation is off Automatic input attenua
123. od WINDow T RACe Y SCALe RPOSition integer Query Syntax DISPlay DEMod WINDow T RACe Y SCALe RPOSition Parameter integer 10 Return parameter Example DISP DEM TRAC Y RPOS 2 121 GW INSTEK GSP 9300 Programming Manual DISPlay DEMod WINDow TRACe Y Set SCALe RVALue Description Sets or queries the Reference value AM FM Hz Syntax DISPlay DEMod WINDow TRACe Y SCALe RVALue lt NRf gt Query Syntax DISPlay DEMod WINDow TRACe Y SCALe RVALue Parameter lt NRf gt AM Unit FM Unit Hz Return parameter lt NR3 gt AM Unit FM Unit Hz Example DISP DEM TRAC Y RVAL 2 DISPlay WINDow NORMal Set Description Sets the display window to the normal trace mode Syntax DISPlay WIN Dow NORMal Example DISP NORM DISPlay WINDow SPECtrogram Set Description Sets the display window to spectrogram mode Syntax DISPlay WIN Dow SPECtrogram Example DISP SPEC GW INSTEK REMOTE CONTROL DISPlay WINDow SPLit NORMal ALTernate Set Description Turns on the Alternate Sweep function for split window mode both windows are in the normal trace mode we also have Spectrogram and Topographic mode Syntax DISPlay WINDow SPLit NORMal ALTernate Example DISP SPL NORM ALT DISPlay WINDow SPLit NORMal ACTive Description Sets which window upper or lower to display the normal trace mode in It also
124. ogress The sweep progress bar shows the progress of bar slow sweeps greater than 2 seconds 22 GW INSTEK GETTING STARTED Status Icon Overview 3G Adapter Demo Kit PreAmp AC Charge Alarm Off Alarm On Amplitude Offset Battery indicator Bandwidth Indicator Indicates that the 3G adapter is installed and turned on Indicates that the demo kit is installed and turned on Indicates that the pre amplifier is on Shown when running on AC power Shown when the AC power is charging the battery Alarm buzzer output is currently off Alarm buzzer output is currently on Indicates that the amplitude shift is active This icon appears when amplitude related functions are used Reference level offset Amplitude Correction Input Z 750 amp Input Z cal 20 Indicates the battery charge Indicates that the RBW or VBW settings are in manual mode GW INSTEK GSP 9300 Programming Manual Average External Lock External Trigger Math Sequence Indicator Sweep Indicator Tracking generator TG Normalization Wake up clock USB Micro SD 24 Indicates that the Average function is active Indicates that the system is now locked and refers to the external reference input signal External trigger signal is being used Trace math is being used Shown when a sequence is running Indicates that the sweep time is manually set Indicates that the tracking gen
125. onfigures the windowing mode and basic display properties Sets the triggering modes File File utilities options Save the trace state etc and save options Recall the trace state etc and recall options Marker Turns the Markers on off and configures the markers The Marker key positions the markers on the trace Finds each maximum and Ses minimum peak Used with the Marker function Auxiliary Access set and edit program sequences The Option Control key allows you Control to setup optional accessories such as the Tracking Generator Power Meter or Demo Kit The System key shows system information settings and other system related functions 14 GW INSTEK GETTING STARTED Preset Local key The Preset key will restore the SCAL spectrum analyzer to the Factory or User Preset settings The Preset key will also return the instrument back to local control after it has been in remote control mode The Quick Save utility allows you save to save either the state trace display screen limit line single press Power key Scroll wheel correction or sequence with only a yellow off blue Turns the instrument on off On Arrow keys Edit values select listed items Increment decrement values in steps select listed items RF input terminal RF INPUT 509 DC 450V MAX 4 30dBm MAX N RF input port Accepts RF inputs e Maximum input 30dBm
126. ording TIME STEP lt time gt Query Syntax SENSe PMETer RECording TIME STEP Parameter lt time gt lt NRf gt Return parameter lt NR3 gt seconds Example PMET REC TIME STEP 10s Set SENSe POWer RF GAIN Description Sets the preamplifier to Auto or Bypass mode or queries its state Syntax SENSe POWer RF GAIN AUTO BYPASS Query Syntax SENSe POWer RF GAIN Parameter AUTO Sets the preamplifier to auto mode Return parameter BYPASS Sets the preamplifier to bypass mode Example POW GAIN AUTO 169 GW INSTEK GSP 9300 Programming Manual SENSe SEMask BAN Dwidth BWIDth Set INTegration Description Sets or queries the channel integration bandwidth for SEM measurements user defined only Syntax SENSe SEMask BAN Dwidth BWIDth INTegration lt freq gt Query Syntax SENSe SEMask BANDwidth BWIDth I NTegration Parameter freq lt NRf gt Return parameter lt NR3 gt Hz Example SEM BAND INT 3 84e 6 SENSe SEMask BANDwidth BWIDth Set RESolution Description Sets or queries the RBW for SEM measurements Syntax SENSe SEMask BAN Dwidth BW1Dth RESolution lt freq gt Query Syntax SENSe SEMask BAN Dwidth BWIDth RESolution Parameter lt freq gt lt NRf gt Return parameter lt NR3 gt Hz Example SEM BAND 2 2e 4 SENSe SEMask BAN Dwidth BWIDth Set RESolution AUTO Description Turns the RBW setting to auto on or manual off
127. ownloaded The IVI driver can also be downloaded from the NI website with a search for the GSP 9300 in the thirdparty drivers section http www ni com downloads instrument drivers Requirements Operating System Windows XP 7 8 GW INSTEK REMOTE CONTROL Functionality 1 Set the Remote interface to USB see page 26 check 2 From the Windows Device Manager sure the IVI driver recognizes the USB connection The GSP 9300 will be recognized as a USB Test and Measurement device IVI when the connection is successful If the connection is not recognized reinstall the IVI driver and set the interface to USB again To access the Device Manager in Windows 7 Start gt Control Panel gt Hardware and Sound gt Device Manager By Device Manager oO Eile Action View Help 9 m i t Gg IDE ATA ATAPI controllers Keyboards 7 Mice and other pointing devices K Monitors amp Network adapters MI Portable Devices Y Ports COM amp LPT a Processors 5 Smart card readers 9 Sound video and game controllers iM System devices Universal Serial Bus controllers USB Test and Measurement Devices USB Test and Measurement Device IVI 3 Start the NI Measurement and Automation Explorer MAX program Using Windows press Start All Programs National Instruments Measurement amp Automation 45 GW INSTEK GSP 9300 Programming Manual Measure
128. parameter 7 68Mcps n 1 for 43 lt P n 2 for 39 lt P lt 43 n 3 for 31 lt P lt 39 n 4 for P lt 31 for 3GPP TDD BS 1 28Mcps n 1 for 34 lt P n 2 for 26 lt P lt 34 n 3 for 26 lt 31 Example SEM W3GPP TDD MOP LEVI SENSe SEMask W3GPP TDD TRANsmit Set MODE Description Selects or queries the transmit mode of the TDD 3GPP test Base station or User Equipment Syntax SENSe SEMask W3GPP TDD TRANsmit MODE BS UE Query Syntax SENSe SEMask W3GPP TDD TRANsmit MODE Parameter BS Base station Return parameter UE User Equipment Example SEM W3GPP TDD TRAN MODE UE GW INSTEK REMOTE CONTROL SENSe SEMask WIMax CHANnel Set BANDwidth BWIDth Description Selects or queries the 802 16 channel bandwidth 10M or 20M channelization Syntax SENSe SEMask WIMax CHANnel BAN Dwidth BWIDth le 7 2e 7 Query Syntax SENSe SEMask WIMax CHANnel BAN Dwidth BWIDth Parameter le 7 lt freq gt Return parameter 2e 7 lt freq gt Example SEM WIM CHAN BAND 1e 7 SENSe SEQuence lt n gt DELete Set Description Deletes the chosen sequence Syntax SENSe SEQuence lt n gt DELete Parameter lt n gt NRI sequence 1 to 5 Example SEQT DEL Set SENSe SWEep EGATe DELay Description Sets or queries the gate delay time Syntax SENSe SWEep EGATe DELlay lt time gt Query Syntax SENSe SWEep EGATe DELlay Parameter lt time gt Gate delay
129. queries the Questionable Status SEM Limit Enable register Syntax STATus QUEStionable SEMLimit ENABle integer Query Syntax STATus QUEStionable SEM Limit ENABle Return parameter Bit Bit Weight Description 0 1 Offset 1 Upper fail 1 2 Offset 1 Lower fail 2 4 Offset 2 Upper fail 3 8 Offset 2 Lower fail 4 16 Offset 3 Upper fail 5 32 Offset 3 Lower fail 6 64 Offset 4 Upper fail 7 128 Offset 4 Lower fail 8 256 Offset 5 Upper fail 9 512 Offset 5 Lower fail Example STAT QUES SEML ENAB 3 STATus QUEStionable SEMLimit EVENt Description Returns the bit weight of the Questionable Status SEM Limit Event register Reading this register will clear the event register Query Syntax STATus QUEStionable SEM Limit EVENt 213 GW INSTEK GSP 9300 Programming Manual Return parameter Bit Bit Weight Description 0 1 Offset 1 Upper fail 1 2 Offset 1 Lower fail 2 4 Offset 2 Upper fail 3 8 Offset 2 Lower fail 4 16 Offset 3 Upper fail 5 32 Offset 3 Lower fail 6 64 Offset 4 Upper fail 7 128 Offset 4 Lower fail 8 256 Offset 5 Upper fail 9 512 Offset 5 Lower fail Example STAT QUES SEML gt 3 STATus QUEStionable SEMLimit Set NTRansition Description Sets or queries the bit weight of the NTR filter for the Questionable Status SEM Limit register Syntax STATus QUEStionable SEMLimit NTRansition integer Query Syntax STATus QUEStionable SEMLimit NTRansition
130. r lt n gt lt NR1 gt offset 1 5 Example SEM OFFS1 STOP ABS 1 5e 1 180 GW INSTEK REMOTE CONTROL SENSe SEMask OFFSet lt n gt STOP Set ABSolute COUPle Description Couples the Absolute Stop amplitude to the Absolute Start amplitude for the selected offset Syntax SENSe SEMask OFFSet lt n gt STOP ABSolute COUPle OFF ON O 1 Query Syntax SENSe SEMask OFFSet lt n gt STOP ABSolute COUPIle Parameter 0 Turns coupling off Turns coupling on OFF Turns coupling off ON Turns coupling on Return parameter 0 Coupling is off Coupling is on Example SEM OFFS1 STOP ABS COUP 0 SENSe SEMask OFFSet lt n gt STOP Set RELative Description Sets or queries the amplitude of the stop frequency of the Relative Mask for the selected offset Syntax SENSe SEMask OFFSet lt n gt STOP RELative lt ampl gt Query Syntax SENSe SEMask OFFSet lt n gt STOP RELative Parameter lt ampl gt lt NR3 gt dBc Return parameter lt n gt lt NR1 gt offset 1 5 Example SEM OFFS1 STOP REL 1 5e 1 181 GW INSTEK GSP 9300 Programming Manual SENSe SEMask OFFSet lt n gt STOP Set RELative COUPle Description Couples the Relative Stop amplitude to the Relative Start amplitude for the selected offset Syntax SENSe SEMask OFFSet lt n gt STOP RELative COUPle OFF ON O 1 Query Syntax SENSe SEMask OFFSet lt n gt STOP RELative COUPIle Parameter 0 Turns coupling off 1 Turns co
131. rd The password appears on the bottom of the screen as it is created Password Press to confirm setting the password Hi SLIP Port 8 Press S9 More F7 Rmtinterface Config F1 gt LAN F2 gt HiSLIPPort to see the Hi Slip Port number HiSlip port 4880 33 GW INSTEK GSP 9300 Programming Manual Reset LAN It may be necessary to reset the LAN configuration settings before the LAN can be used 9 Press sem gt More F7 gt RmtInterface Config F1 gt LAN Reset F3 to reset the LAN 10 The GSP 9300 will now automatically reboot Each time the LAN is reset the default Note di d password is restored Default password Ixi WNpwd 34 GW INSTEK REMOTE CONTROL Configure RS232C Background The RS232C interface is used for remote control with a PC RS232C Baud Rate Stop bit 1 fixed Configuration Parity none fixed Data bit 8 fixed settings Connection Connect an RS232C cable from ae the PC to the rear panel RS232 port 1 Press 9e More F7 RmtlInterface Config F1 gt RS232 BaudRate F4 to set the baud rate 300 600 1200 2400 4800 9600 19200 38400 57600 115200 RS232C Remote Control Function Check Functionality Invoke a terminal application such as Realterm check To check the COM port No see the Device Manager in the PC For WinXP Control panel System Hardware tab Run this query command via the terminal after the instrument has
132. rn Y Cancel password Menu tree to enter the password 5 The password appears on the bottom of the screen as it is created Password 6 Press to confirm setting the password Hi SLIP Port 7 Press 5 More F7 Rmtlnterface Config F1 LAN F2 gt HiSLIPPort to see the Hi Slip Port number HiSlip port 4880 29 GW INSTEK GSP 9300 Programming Manual Reset LAN It may be necessary to reset the LAN configuration settings before the LAN can be used 8 Press sem gt More F7 gt RmtInterface Config F1 gt LAN Reset F3 to reset the LAN 9 The GSP 9300 will now automatically reboot Each time the LAN is reset the default Note password is restored Default password Ixi WNpwd Configure the WLAN Interface The WLAN settings operate using any standard 3G USB modem For remote locations using a 3G modem allows you to access the GSP 9300 web server or to control the GSP 9300 via remote control commands Background To use the GSP 9300 as a server using a 3G modem you must first obtain a fixed IP address from a network provider Each provider will assign different fixed IP addresses WLAN IP Address Default Gateway configuration Subnet Mask DNS Server Settings 30 GW INSTEK REMOTE CONTROL Connection Connect the 3G USB modem to the front panel USB A port The 3G status icon will appear when the 3G USB adapter is connected When it is first connected it will
133. rn peak threshold on Return parameter 0 Peak threshold is off 1 Peak threshold is on Example CALC MARK PEAK THR STAT ON CALCulate MARKer lt n gt SET Set Description Sets the selected marker to one of five preset positions Query Syntax CALCulate MARKer lt n gt SET CENTer STARt STOP STEP RLEVel Parameter lt n gt lt NR1 gt Marker number 1 6 CENTer Set to center frequency STARt Set to start frequency STOP Set to stop frequency STEP Set to CF STEP frequency RLEVel Set to the Reference level Example CALC MARKI SET CENT 103 GW INSTEK GSP 9300 Programming Manual Set CALCulate MARKer lt n gt STATe Description Sets or queries the state of the selected marker Syntax CALCulate MARKer lt n gt STATe ON OFF 1 0 Query Syntax CALCulate MARKer lt n gt STATe Parameter lt n gt NRI Marker number 1 6 0 Turn the selected marker off 1 Turn the selected marker on OFF Turn the selected marker off ON Turn the selected marker on Return parameter 0 The selected marker is off 1 The selected marker on Example CALC MARK1 STAT ON Set CALCulate MARKer TABLe STATe Description Sets or queries the state of the marker table Syntax CALCulate MARKer TABLe STATe ON OFF 1 0 Query Syntax CALCulate MARKer TABLe STATe Parameter 0 Turn the table off 1 Turn the table on OFF Turn the table off ON Turn the table on Return parameter 0 The table is off 1 The table
134. scription Sets or queries the value of the TotalPwrRef amplitude for SEM measurements Syntax SENSe SEMask CARRier POWer lt ampl gt Query Syntax SENSe SEMask CARRier POWer Parameter lt ampl gt lt NRf gt Return parameter lt NR3 gt dBm Example SEM CARR POW 2 dbm Set SENSe SEMask FREQuency SPAN Description Sets or queries the channel span for SEM measurements user defined only Syntax SENSe SEMask FREQuency SPAN lt freq gt Query Syntax SENSe SEMask FREQuency SPAN Parameter lt freq gt lt NR3 gt Return parameter lt NR3 gt Hz Example SEM FREQ SPAN 2 2e 7 Set SENSe SEMask GWLan MODulation Description Sets or queries the modulation type for the 802 116 SEM measurement Syntax SENSe SEMask GWLan MODulation GRoup lt n gt Query Syntax SENSe SEMask GWLan MODulation 172 GW INSTEK REMOTE CONTROL Parameter lt n gt 1 ERP DSSS ERP PBCC ERP CCK Return parameter lt n gt 2 ERP OFDM DSSS OFDM Example SEM GWL MOD GRI Set SENSe SEMask HELP STATe Description Turns the on screen help window on off or queries its state Syntax SENSe SEMask HELP STATe OFF ON 0 1 Query Syntax SENSe SEMask HELP STATe Parameter 0 Turns the help window off Turns the help window on OFF Turns the help window off ON Turns the help window on Return parameter 0 Help window is off Help window is on Example SEM HELP STATE 1 SENSe SEMas
135. seenossocsotsatetsoesess SEINSe A CPRiSPA Ceisiasssdisssssisedstesassseessdssezeas er patente SENSeJ ASET AMPLitude si 5 5 5 1 4 5 5 i obtineret tttm ESENS ASET SPAN rinnan 68 GW INSTEK REMOTE CONTROL RE SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe SENSe EMIFilter BANDwidth BWIDth 160 161 SENSe FREQuency CENTet STEP 161 SENSe FREQuency CENTer STEP AUTO 161 SENSe FREQuency OFFSet eee 162 SENSe FREQuency SPAN eee 162 SENSe FREQuency SPAN FULL es 162 SENSe FREQuency SPAN PREVI0US 162 SENSe FREQuency STAREt eeeeeeenee 163 5 163 SENSe HARMonic FUN Damental FREQuency 163 SENSe HARMonic NUMBer eee SENSe LIMit lt n gt DELete SENSe JITTer OFFSet STARt SENSe JITTer OFFSecSTOP SENSe NDB BAND width BWIDth ASET SPAN AUTO
136. starts the CTB measurement Syntax CALCulate CTB RESTart CALCulate DELTamarker lt n gt PAIR SPAN Set Description Sets the span between the chosen marker and the delta marker Syntax CALCulate DELTamarker lt n gt PAIR SPAN freq Parameter lt n gt Marker number lt freq gt lt NRf gt frequency of span Example CALC DELT1 PAIR SPAN 1e 9 CALCulate DELTamarker lt n gt PAIR CENTer Description Takes the current span between the chosen markers and relocates that center frequency to the chosen center frequency Syntax CALCulate DELTamarker lt n gt PAIR CENTer lt freq gt Parameter lt n gt Marker number lt freq gt lt NRf gt center frequency Example CALC DELTT PAIR CENT 1e 9 Set CALCulate DELTamarker lt n gt X Description Sets or queries the selected delta marker position 86 GW INSTEK REMOTE CONTROL Syntax CALCulate DELTamarker lt n gt X freq Query Syntax CALCulate DELTamarker lt n gt X Parameter lt n gt Marker number Return parameter lt freq gt lt NR3 gt frequency in Hz Example CALC DELTT X gt 1e 9 CALCulate DELTamarker lt n gt Y Que Description Returns the selected delta marker Y axis value Query Syntax CALCulate DELTamarker lt n gt Y Parameter lt n gt Marker number Return parameter lt rel_ampl gt lt NR3 gt in dB Example CALC DELT1 Y gt 1 032e 1 CALCulate DEMod AM RESult CURRent
137. ster e Event Register Event Enable Register Condition The condition registers report the state of the Registers GSP 9300 Condition registers can only be read PTR Registers The positive transistion registers are used to filter for events that occur from a negative to a positive transition NTR Registers The negative transition registers are used to filter for events that occur from a positive to negative transistion Event Registers The PTR NTP registers dictate the type transistion conditions that will set the corresponding bits in the event registers The event registers can only be read Reading an event register will clear it Event Enable The event enable registers determine which Registers events in the corresponding event registers will set the summary bits in a higher order register 56 GW INSTEK REMOTE CONTROL To higher order register 9 Event Condition Enable Register Register Register D amp o EH Te F SZ Status Byte Register STB Overview The Status Byte register consolidates the status events of all the status registers The Status Byte register can be cleared with the CLS command Any bits set in the Status byte register acts as a summary register for all the other status registers and indicates if there is a service request an error in the Error Queue or data in the Output Queue Reading the Status Byte register wil
138. sure the spectrum anlayzer is off before proceeding GPIB Connect a GPIB cable from a qe GPIB controller to the GPIB port e on the spectrum analyzer A y X97 Turn the spectrum analyzer on GW INSTEK REMOTE CONTROL 4 Press 9e More F7 RmtInterface Config F1 gt GPIB Addr F1 and set the GPIB address GPIB address 0 30 GPIB constraints Maximum 15 devices altogether 20m cable length 2m between each device e Unique address assigned to each device At least 2 3 of the devices turned On e No loop or parallel connection Configure the LAN and LXI Interface The GSP 9300 is a class C LXI compliant instrument The LXI specification allows instrumentation to be configured for remote control or monitoring over a LAN or WLAN The GSP 9300 also supports HiSlip HiSlip High Speed LAN Instrument Protocol is an advanced LAN based standard for 488 2 communications For details on the LXI specification and compliance classes please see the LXI website 9 http www lxistandard org Background The LAN interface is used for remote control over a network The spectrum analyzer supports DHCP connections so the instrument can be automatically connected to an existing network Alternatively network settings can also be manually configured LAN IP Address Default Gateway configuration Subnet Mask DNS Server Settings DHCP on off Connection Connect an Ethernet c
139. t Parameter lt freq gt lt NRf gt Only 200Hz 9kHz 120kHz are valid settings Example EMIF BAND 2 0e 2 160 GW INSTEK REMOTE CONTROL Set SENSe FREQuency CENTer Description Sets or queries the center frequency Syntax SENSe FREQuency CENTer freq Query Syntax SENSe FREQuency CENTer Parameter lt freq gt lt NRf gt Return parameter lt NR3 gt Hz Example FREQ CENT 1 0e 9 Set SENSe FREQuency CENTer STEP Description Sets or queries the CF Step frequency Syntax SENSe FREQuency CENTer STEP freq Query Syntax SENSe FREQuency CENTer STEP Parameter lt freq gt lt NRf gt Return parameter lt NR3 gt Hz Example FREQ CENT STEP 1 0e 3 Set SENSe FREQuency CENTer STEP AUTO Description Turns the CF Step frequency setting to auto on or manual off or queries its state Syntax SENSe FREQuency CENTer STEP AUTO OFF ON O 1 Query Syntax SENSe FREQuency CENTer STEP AUTO Parameter 0 Turn CF Step to manual off 1 Turn CF Step to auto on OFF Turn CF Step to manual off ON Turn CF Step to auto on 161 GW INSTEK GSP 9300 Programming Manual Return parameter 0 CF Step is set to manual 1 CF Step is set to automatic Example FREQ CENT STEP AUTO OFF Set SENSe FREQuency OF FSet Description Sets or queries the frequency offset settings Syntax SENSe FREQuency OFF Set freq Query Syntax SENSe FREQue
140. t ABSolute Parameter lt ampl gt lt NR3 gt dBm Return parameter lt n gt lt NR1 gt offset 1 5 Example SEM OFFS1 STAR ABS 1 5e 1 SENSe SEMask OFFSet lt n gt STARt Set RELative Description Sets or queries the amplitude of the start frequency of the Relative Mask for the selected offset 179 GW INSTEK GSP 9300 Programming Manual Syntax SENSe SEMask OFFSet lt n gt STARt RELative lt ampl gt Query Syntax SENSe SEMask OFFSet lt n gt STARt RELative Parameter lt ampl gt lt NR3 gt dBc Return parameter lt n gt NRI offset 1 5 Example SEM OFFS1 STAR REL 2 5e 1 Set SENSe SEMask OFFSet lt n gt STATe Description Turns the selected offset on off or queries its state Syntax SENSe SEMask OF FSet lt n gt STATe OFF ON 0 1 Query Syntax SENSe SEMask OFFSet lt n gt STATe Parameter 0 Turns the selected offset off 1 Turns the selected offset on OFF Turns the selected offset off ON Turns the selected offset on Return parameter 0 The selected offset is off 1 The selected offset is on Example SEM OFFST STAT 1 SENSe SEMask OFFSet lt n gt STOP Set ABSolute Description Sets or queries the amplitude of the stop frequency of the Absolute Mask for the selected offset Syntax SENSe SEMask OFFSet lt n gt STOP ABSolute lt ampl gt Query Syntax SENSe SEMask OFFSet lt n gt STOP ABSolute Parameter lt ampl gt lt NR3 gt dBm Return paramete
141. t CONDition 209 e ACPLimit ENABle 210 e ACPLimit EVENEtE 210 e ACPLimit NTRansition 211 e ACPLimit PTRansition 211 eSEMLimitENABle 213 e SEMLimit EVENE 213 eSEMLimit NTRansition 214 eSEMLimit PTRansition 215 SSTATus QUEStionable TOILimit ENA Ble 216 SSTATus QUEStionable TOILimit EVENtE 216 SSTATus QUEStionable TOILimit NTRansition 216 SSTATus QUEStionable TOILimit PTRansition 217 SSTA Tus PRESE nee css sese cous istos thread 217 STATus OPERation CONDition Query Description Returns the bit weight of the Operation Status Condition register Query Syntax STATus OPERation CONDition 202 GW INSTEK REMOTE CONTROL Return parameter Bit Bit Weight Description 0 2 N A Not used 3 8 Sweeping 4 16 Measuring 5 32 Wait for Trigger 6 15 N A Not used Example STAT OPER COND 28 Set STATus OPERation ENABle Description Sets or queries the Operation Status Event Enable register Syntax STATus OPERation ENABle integer Query Syntax STATus OPERation ENABle Return parameter Bit Bit Weight Description 0 2 N A Not used 3 8 Sweeping 4 16 Measuring 5 32 Wait for Trigger 6 15 N A Not used Example STAT OPER ENAB 32 STATus OPERation EVENt Description Returns the bit weight of the Operation Status E
142. t T 1 0 0 0 SYSTem VERSion SOFTware Query Description Returns the system software version Query Syntax SYSTem VERSion SOFTware 200 GW INSTEK REMOTE CONTROL Return parameter lt string gt T1 00_2014 05 28_22 Where T1 00 firmare version 2014 year 05 month 28 day 22 internal reference not for end user Example SYST VERS SOFT gt T1 00_2014 05 28_22 n 201 GW INSTEK GSP 9300 Programming Manual STATus Commands SSTATus OPERation CONDJition eee 202 STATus OPERation ENABle SSTATus OPERationEEVENI STATus OPERation NTRansition eee SSTATus OPERation PTRansition eee SSTATus QUEStionab STATus QUEStionable SSTATus QUEStionab SSTATus QUEStionab SSTATus QUEStionab SSTATus QUEStionab SSTATus QUEStionab SSTATus QUEStionab SSTATus QUEStionab SSTATus QUEStionab SSTATus QUEStionab STATus QUEStionab SSTATus QUEStionab SSTATus QUEStionab SSTATus QUEStionab SSTATus QUEStionab SSTATus QUEStionab STATus QUEStionab STATus QUEStionab SSTATus QUEStionab SSTATus QUEStionab e CONDition eSEMLimit CONDition 212 e TOILimit CONDition 215 e FREQuency CONDition 207 e FREQuency ENABBle 208 e FREQuency EVEN E 208 e FREQuency NTRansition 208 e FREQuency PTRansition 209 e ACPLimi
143. t ampl gt lt NRf gt Power or voltage Return parameter lt NR3 gt Example SOUR POW 30 dbm SOURce POWer LEVel IM Mediate Set AMPLitude OFFSet Description Sets or queries the tracking generator offset level Syntax SOURce POWer LEVel IMMediate AMPLitude OFFSet lt rel_ampl gt Query Syntax SOURce POWer LEVel IMMediate AMPLitude OFFSet 191 GW INSTEK GSP 9300 Programming Manual Parameter lt rel_ampl gt lt NRf gt Return parameter lt NR3 gt dB Example SOUR POW OFFS 10 db SOURce POWer LEVel MMediate Set AMPLitude STEP Description Sets or queries the tracking generator step level Syntax SOURce POWer LEVel I MMediate AM PLitude STEP rel ampl Query Syntax SOURce POWer LEVel IMMediate AM PLitude STEP Parameter lt rel_ampl gt lt NRf gt Return parameter lt NR3 gt dB Example SOUR POW STEP 5 db SOURce POWer LEVel IM Mediate Set AMPLitude STEP AUTO Description Turns the tracking generator step level setting to auto on or manual off Syntax SOURce POWer LEVel IMMediate AM PLitude STEP AUTO OFFJON 0 1 Query Syntax SOURce POWer LEVel IM Mediate AM PLitude STEP AUTO Parameter 0 Turn TG step level to manual off 1 Turn TG step level to auto on OFF Turn TG step level to manual off ON Turn TG step level to auto on Return parameter 0 TG step level is set to m
144. tax DISPlay ENABle OFF ON 0 1 Query Syntax DISPlay ENABle Parameter 0 Turn LCD backlight off 1 Turn LCD backlight on OFF Turn LCD backlight off ON Turn LCD backlight on Return parameter 0 LCD backlight is off 1 LCD backlight is on Example DISP ENAB gt 118 GW INSTEK REMOTE CONTROL DISPlay DEMod WIN Dow TRACe X Set SCALe AUTO Description Turns auto scale on off for AM FM demodulation or queries its state When set to ON the auto scale function will be executed continuously Syntax DISPlay DEMod WINDow TRACe X SCALe AUTO OFF ON O 1 Query Syntax DISPlay DEMod WINDow TRACe X SCALe AUTO Parameter 0 Turn Auto Scale off Turn Auto Scale on OFF Turn Auto Scale off ON Turn Auto Scale on Return parameter 0 Auto Scale is off Auto Scale is on Example DISP DEM TRAC X AUTO ON DISPlay DEMod WINDow TRACe X Set SCALe PDIVision Description Sets or queries the time axis scale div Syntax DISPlay DEMod WINDow TRACe X SCALe PDIVision time Query Syntax DISPlay DEMod WINDow TRACe X SCALe PDIVision Parameter time lt NRf gt Return parameter lt NR3 gt Seconds Example DISP DEM TRAC X PDIV 2 ms 119 GW INSTEK GSP 9300 Programming Manual DISPlay DEMod WINDow TRACe X Set SCALe RPOSition Description Sets or queries the Reference Position of the trace for AM FM demodulation x axis grid division Syntax DIS
145. te NORMalize STATe ON OFF 1 0 Query Syntax CALCulate NORMalize STATe Parameter 0 Turn normalization off 1 Turn normalization on OFF Turn normalization off ON Turn normalization on Return parameter 0 normalization is off 1 normalization is on Example CALC NORM STAT ON 108 GW INSTEK REMOTE CONTROL Set CALCulate OCBW STATe Description Turns the OCBW measurement on off or queries its state Syntax CALCulate OCBW STATe ON OFF 1 0 Query Syntax CALCulate OCBW STATe Parameter 0 Turn OCBW off 1 Turn OCBW on OFF Turn OCBW off ON Turn OCBW on Return parameter 0 OCBW is off 1 OCBW is on Example CALC OCBW STAT ON CALCulate OCBW BANDwidth BWIDth Description Returns the OCBW bandwidth measurement Query Syntax CALCulate OCBW BANDwidth BWIDth Return parameter lt NR3 gt OCBW bandwidth in Hz Example CALCCOCBW BAND gt 4 1e 03 CALCulate OCBW CHPower Description Returns the OCBW channel power measurement Query Syntax CALCulate OCBW CH Power Return parameter lt NR3 gt OCBW channel power in the current Y axis unit Example CALCCOCBW CHP gt 9 13e 01 109 GW INSTEK GSP 9300 Programming Manual CALCulate OCBW POWer Query Description Returns the OCBW total power measurement Query Syntax CALCulate OCBW POWer Return parameter lt NR3 gt OCBW total power in the current Y axis unit Example CALC OCBW POW gt 1
146. te citri tese ae edi SYSTem VERSion HARDwate wA SYSTem VERSion SOF T wate eee 200 Set SYSTem ALARm STATe Description Sets the system alarm output on off Syntax SYSTem ALARm STATe OFF ON 0 1 Query Syntax SYSTem ALARm STATe Parameter 0 Turn the alarm off 1 Turn the alarm on OFF Turn the alarm off ON Turn the alarm off Return parameter 0 The alarm is off 1 The alarm is on 194 GW INSTEK REMOTE CONTROL Example SYST ALAR STAT 1 Set SYSTem CLOCk lt n gt DATE Description Sets the day for the selected wake up clock Syntax SYSTem CLOCk lt n gt DATE MONday TUESday WEDnesday THURsday FRIday SATurday SUNday Query Syntax SYSTem CLOCk lt n gt DATE Parameter lt n gt Wake up clock number 1 to 7 Return parameter MONday Set to Monday TUESday Set to Tuesday WEDnesday Set to Wednesday THURsday Set to Thursday FRIday Set to Friday SATurday Set to Saturday SUNday Set to Sunday Example SYST CLOC1 DATE MON Set SYSTem CLOCk lt n gt MODE Description Sets the alarm mode for the selected wake up clock Syntax SYSTem CLOCk lt n gt MODE REPeat SINGle Query Syntax SYSTem CLOCk n MODE Parameter n Wake up clock number 1 to 7 Return parameter REpeat Set the wake up clock to repeat SINGle Set the wake up clock to single Example SYST CLOC1 MODE REP 195 GW INSTEK GSP 9300 Programming Manual
147. ters Overview Description The status registers are used to determine the status of the spectrum analyzer The status registers maintain the status of the pass fail limits trigger status and other operation statuses The status registers are arranged in a number of groups e Questionable Status Registers e Standard Event Status Registers e Operation Status Registers e Status Byte Register e Service Request Enable Register e Error Event Queue e Output Buffer 54 GW INSTEK REMOTE CONTROL es i Questionable Questionable Questionable Questionable P Essar FENNE Status ACP Limit Status SEM Status TOI Limit Status Demod g Register Limit Register Register Fail Register 15 15 15 15 15 15 14 14 14 14 14 14 13 13 13 13 13 13 Not used 12 12 12 12 12 12 Not used 11 11 11 11 11 11 Not used Not used 10 10 10 10 10 10 9 9 9 9 Offset 5 9 9 Lower Fail Not used Not used 8 8 8 8 Upper Fail 8 8 Adj3 Low Offset 4 7 7 7 Fail 7 Lower Fail 7 7 Adj3 High Offset 4 6 6 6 Fail 6 Upper Fail 6 6 Wait for Invalid Adj2 Low Offset 3 5 trigger 5 span of BW 5 Fail 5 Lower Fail 5 5 Adj2 High Offset 3 4 Measuring 4 4 Fail 4 Upper Fail 4 4 Adjt Low Offset 2 3 Sweeping 3 3 Fail 3 Lo
148. time in seconds Return parameter Example SWE EGAT DEL 10 ms 187 GW INSTEK GSP 9300 Programming Manual Set SENSe SWEep EGATe LENGth Description Sets or queries the gate length time Syntax SENSe SWEep EGATe LENGth lt time gt Query Syntax SENSe SWEep EGATe LENGth Parameter lt time gt Gate length time in seconds Return parameter Example SWE EGAT LENG 10 ms Set SENSe SWEep EGATe STATe Description Turns the gated sweep mode on off or queries its state Syntax SENSe SWEep EGATe STATe OFF ON 0 1 Query Syntax SENSe SWEep EGATe STATe Parameter 0 Turns gated sweep mode off 1 Turns gated sweep mode on OFF Turns gated sweep mode off ON Turns gated sweep mode on Return parameter 0 Gated sweep mode is off 1 Gated sweep mode is on Example SWE EGAT STAT 1 Set SENSe SWEep MODE Description Sets or queries the sweep mode Syntax SENSe SWEep MODE FAST NORMal Query Syntax SENSe SWEep MODE Parameter FAST Sets to fast mode NORMAL Sets to normal mode GW INSTEK REMOTE CONTROL Return parameter FAST Sets to fast mode NORMAL Sets to normal mode Example SENS SWE MODE FAST Set SENSeJ SWEep TIME Description Sets the sweep time Syntax SENSe SWEep TIME time Query Syntax SENSe SWEep TIME Parameter lt time gt Sweep time in seconds Return parameter Example SWE TIME 60 ms Set SENSe SWEep TIME AUTO
149. tion 5 erri nig 170 SENSe SEMask BAND width BWIDth RESolution AU TO ti tete oi 5 5 5 5 SENSe SEMask CARRier CPSD sss SENSe SEMask CARRier POWer SENSe SEMask FREQuency SPAN 12 SENSe SEMask GWLan MODulation 172 SENSe SEMask HELP STATe eee 73 SENSe SEMask NWLan CHANnel BAND width BWIDth eee 73 SENSe SEMask OF FSet lt n gt ADDition BANDwidth BWIDth RESolution 74 SENSe SEMask OFFSet lt n gt ADDition PRE Quency S TARE 76 SENSe SEMask OF FSet lt n gt ADDition EFREQuency S T OD iei tipi citi i cite 76 SENSe SEMask OFFSet lt n gt ADDition STARGA BSOlUtE or 177 SENSe SEMask OF FSet lt n gt ADDition STOP ABSolute itii disessinddadsseustaseideassssedsdevsesp idesseas 177 SENSe SEMask OFFSet lt n gt BANDwidth BWIDth ERESolution retient pete 177 SENSe SEMask OFFSet lt n gt BANDwidth BWIDth RBSolution AU TG nidi retro 178 SENSe SEMask OF FSet lt n gt FREQuency STARt 178 SENSe SEMask OF FSet lt n gt FREQuency STOP 179 SENSe SEMask OF FSet lt n gt STARt ABSolute 179 GW INSTEK REMOTE CONTROL SENSe SEMask OFFSet lt n gt STARt RELative 179 SENSe SEMask OFFSet lt n gt STATe
150. tion 0 1 314 lower fail 1 2 34 upper fail Example STAT QUES TOIL PTR 1 STATus PRESet Set Description Loads the preset settings Syntax STATus PRESet TRACe Commands FRA uideat fecti dachte 217 PIXel TRACES 218 TRACe DATAJ Description Returns the trace data for the selected trace in CSV format There are 601 data points in total Query Syntax STRACe DATA TRACe lt n gt 217 GW INSTEK GSP 9300 Programming Manual Parameter lt n gt NRI 1 4 Return Parameter csv data Trace data in CSV format point 1 point 2 point n Example TRAC TRAC gt 5 234e 01 4 593e 01 5 533e 01 4 604e 01 gt 5 353e 01 4 557e 01 5 280e 0 1 4 785e401 5 459e 01 4 578e4 0 1 PIXel TRACe lt n gt Description Returns the trace pixel data real pixel value x100 for the selected trace in binary coded decimal format represented by 2 characters per pixel Highbyte Lowbyte Each trace has 601 pixels In total the query will return 1208 characters 601x2 1 EOF character If you wish to determine the real value of a pixel simply divide the binary coded decimal character by 100 A binary coded decimal to ASCII lookup table is included in the Appendix on page 227 The pixel data that is returned is the y axis pixel data for each nth pixel The pixel data is taken from the display image data 450 x 600 pixels total Image data f 58
151. tion is on Example INP ATT AUTO ON 132 GW INSTEK REMOTE CONTROL Set INPut IMPedance Description Sets or queries the input impedance in Q Syntax INPut IMPedance 50 75 Query Syntax INPut IMPedance Parameter 50 NRI Q Return parameter 75 NRI Q Example INP IMP 75 Set INPut OFFSet Description Sets or queries the input offset Input Z Calibration Syntax INPut OFFSet rel ampl Query Syntax INPut OFFSet Parameter lt rel_ampl gt lt NR3 gt dB Return parameter Example INP OFFS 10 dB 133 GW INSTEK GSP 9300 Programming Manual MMEMory Commands MMEMory CATalog reiini 134 MMEMory CDlIRectory MMEMory COPDY s MMBMoty DELete ueeetiti bees iere ftoi stebe eeepc onto MMEMory DESTination eee MMEMory LOAD CORRection T MMBMoty EOAJD LEMit o oeaecaen oen teen oreet peres MMEMory LOAD PMETer MMEMory LOAD SEQuence 7 MMEMory lOAD STATe tenir tnnt esee MMEMory REName MMEMory STORe CORRection eee 139 MMEMory STORe LIMit MMEMory STORe PMETer eee MMEMory STORe SCReen eene MMEMory STORe SEQuence 7 MMEMory STOReS LATe eerie tnnc MMEMory STORe TRACe eee
152. ulate DEMod FM STATe Description Sets or queries the state of the FM Analysis function Syntax CALCulate DEMod FM STATe ON OFF 1 0 Query Syntax CALCulate DEMod FM STATe Parameter 0 Turn FM Analysis off Turn Analysis on OFF Turn FM Analysis off ON Turn FM Analysis on Return parameter 0 FM Analysis is off FM Analysis is on Example CALC DEM FM STAT 1 CALCulate DEMod RESet Set Description This command will reset the max and min records for the current demodulation analysis Syntax CALCulate DEMod RESet CALCulate HARMonic DISTortion Description Returns the harmonic distortion as a percentage of the fundamental and as dBc Query Syntax CALCulate HARMonic DISTortion Return parameter lt gt lt dBc gt 926 THD as 96 lt NR1 gt format lt dBc gt THD as dBc lt NRf gt format Query Example CALC HARM DIST gt 32 34 9 81e 00 GW INSTEK GSP 9300 Programming Manual CALCulate HARMonic RESult Query Description Returns the amplitude of each harmonic in dBm Query Syntax CALCulate HARMonic RESult lt fundamental gt lt harmonic 2 gt lt harmonic n gt lt fundamental gt Returns the amplitude of the fundamental harmonic frequency in dBm lt harmonic n gt Returns the amplitude of the nth harmonic in dBm Query Example CALC HARM RES gt 7 572e 01 0 00e 00 0 00e 00 0 00e 00 0 00e 00 Set CALCulate HARMonic STATe Description S
153. ulate CNR STATe Parameter 0 CNR is off 1 CNR is on OFF CNR is off ON CNR is on Return parameter 0 CNR is off CNR is on Query Example CALC CNR STAT gt CALCulate CSO RESult Query Description Returns the CSO measurement result in dB Query Syntax CALCulate CSO RESult Return parameter lt NR3 gt CSO measurement in dB Query Example CALC CSO RES gt 4 04e 00 g GW INSTEK REMOTE CONTROL Set CALCulate CSO STATe Description Sets or queries the state of the CSO measurement function Syntax CALCulate CSO STATe ON OFF 1 0 Query Syntax CALCulate CSO STATe Parameter 0 CSO is off 1 CSO is on OFF CSO is off ON CSO is on Return parameter 0 CSO is off 1 CSO is on Query Example CALC CSO STAT gt CALCulate CTB RESult Description Returns the CTB measurement result in dB Query Syntax CALCulate CTB RESult Return parameter lt NR3 gt CTB measurement in dB Query Example CALC CTB RES gt 4 237e 01 Set CALCulate CTB STATe Description Sets or queries the state of the CTB measurement function Syntax CALCulate CTB STATe ON OFF 1 0 Query Syntax CALCulate CTB STATe Parameter 0 CTB is off 1 CTB is on OFF CTB is off GW INSTEK GSP 9300 Programming Manual ON CTB is on Return parameter 0 CTB is off CTB is on Query Example CALC CTB STAT 20 CALCulate CTB RESTart Set Description Re
154. upling on OFF Turns coupling off ON Turns coupling on Return parameter 0 Coupling is off Coupling is on Set SENSe SEMask OFFSet lt n gt TEST Description Sets or queries the masks to use for the Fail Mask s Syntax SENSe SEMask OFFSet nz TEST ABS REL AND OR Query Syntax SENSe SEMask OFFSet lt n gt TEST Parameter ABS Absolute mask Return parameter REL Relative mask AND Absolute and Relative mask OR Absolute or Relative mask Example SEM OFFS 1 TEST ABS Set SENSe SEMask SELect Description Selects or queries the type of spectrum emission mask GW INSTEK REMOTE CONTROL Syntax SENSe SEMask SELect MANual W3GPP BWLan GWLan NWLan WIMax Query Syntax SENSe SEMask SELect Parameter MANual User defined SEM Return parameter W3GPP 3GPP SEM BWLan 802 11b SEM GWLan 802 11g SEM NWLan 802 11n SEM WIMax 802 16 SEM Example SEM SEL MAN Set SENSe SEMask TYPE Description Selects or queries the method used as the reference for calculating the offset power Total power reference or power spectral density reference Syntax SENSe SEMask TYPE PSDRef TPRef Query Syntax SENSe SEMask TYPE Parameter PSDRef Power Spectral Density Reference Return parameter TPRef Total Power Reference Example SEM TYPE PSDR Set SENSe SEMask W3GPP DUPLex TYPE Description Selects or queries the type of duplexing used for 3GPP tests Syntax SEN
155. vent register Reading this register will clear the event register Query Syntax STATus OPERation EVENt 203 GW INSTEK GSP 9300 Programming Manual Return parameter Bit Bit Weight Description 0 2 N A Not used 3 8 Sweeping 4 16 Measuring 5 32 Wait for Trigger 6 15 Not used Example STAT OPER 8 Set STATus OPERation NTRansition Description Sets or queries the bit weight of the NTR filter for the Operation Status register Syntax STATus OPERation NTRansition integer Query Syntax STATus OPERation NTRansition Return parameter Bit Bit Weight Description 0 2 N A Not used 3 8 Sweeping 4 16 Measuring 5 32 Wait for Trigger 6 15 Not used Example STAT OPER NTR 32 Set STATus OPERation PTRansition Description Sets or queries the bit weight of the PTR filter for the Operation Status register Syntax STATus OPERation PTRansition integer Query Syntax STATus OPERation PTRansition 204 GW INSTEK REMOTE CONTROL Return parameter Bit Bit Weight Description 0 2 N A Not used 3 8 Sweeping 4 16 Measuring 5 32 Wait for Trigger 6 15 N A Not used Example STAT OPER PTR 32 STATus QUEStionable CONDition Description Returns the bit weight of the Questionable Status Condition register Query Syntax STATus QUEStionable CONDition Return parameter Bit Bit Weight Description 5 32 Frequency 8 256 Uncal
156. vic Aiterfaces _ GPIB Interface properties can only be changed by an Administrator mm 6 58 5 Perfor Name Value Um ASRLL INSTR COM1 7 ASRDSNSTR COMZ IP Address Not Applicable ASRLIO INSTR LPT1 amp General Settings GPIB USB HS GPIB Interface ID GPIB3 3 INSTR Primary Address 0 5 Network Devices Secondary Address None Software system Controller fil MI Drivers derma 88 Remote Systems Autopolling Termination Settings Send at End of Write Select the device GPIB address of GSP 9300 that now appears in the System gt Devices and Interfaces gt GPIBX gt Instrument X node Click on the VISA Properties tab on the bottom Click Open Visa Test Panel s Instrument 0 Measurement amp Automation Explor File Edit View Tools Help a E My System 4 Devices and I Eh Open VISA est Panel Save Ed 4 Wi GPIB3 GPI eee mJ GPIB3 3 INSTR ASRLi INSTR COM1 Pl b COMI Device Type GPIB Instrument ASRL10 INSTR LPT1 GPIB USB HS VISA Alias on My System GPIB3 3 INSTR 4 Network Devices amp Software Device Status ffi MI Drivers This device is working properly Remote Systems Help Device Usage Dev Find and Download Instrument Drivers Select the method you wantto use D Launch LabVIEW IDFinder LabVIEW gted Search IDNet frnfidnet and install manual
157. wer Fail 3 3 High Offset 2 2 2 Notused 2 Fail 2 Upper Fail 2 2 Main Channel Offset 1 3rd Lower 1 Not used 1 1 Low Fail 1 Lower Fail 1 Fail 1 FM Fail Main Channel Offset 1 3rd Upper 0 0 O Hion Fai O Upper Fail 0 Fail 0 AM Fail Questionable Status Register 15 Demod Fail 14 2FSK Fail Pmet Limit 13 Fail 12 Limit i Standard Event Service ESHER SEIS Byte SXatus Enable d Event Enable Register Register Register Register 11 SEM Limit Status F 7 amp 7 Operation 7 amp 7 Power on 10 ACP Limit User ead 6 amp 6 RQS MSS 6 amp 6 Request 9 Limit Fail 5 amp 5 ESB 5 amp 5 Command 8 Uncal 4 amp 4 MAV 4 amp 4 Bon 7 rror sae D Not used 1 evice 3 amp 3 ausstionable 3 amp 3 dependent error 6 2 2 pid 2 amp 2 Query Error 5 Frequency Request 1 amp 1 1 amp 1 control 4 mE Operation 0 amp 0 0 amp 0 complete 3 2 Notused Eee Output Buffer 1 55 GW INSTEK GSP 9300 Programming Manual Status Register Each status register excluding the status byte Structure register is divided into a number of register structures e Condition register e Positive transition register e Negative transition regi
158. x Min Hold function on Return parameter 0 The Max Min Hold function is off 1 The Max Min Hold function is on Example PEMT HOLD STAT 0 Set SENSe PMETer LLIMit Que Description Sets or queries the power meter low limit for pass fail tests Syntax SENSe PMETer LLIMit lt ampl gt Query Syntax SENSe PMETer LLIMit Parameter lt ampl gt lt NRf gt power unit default dBm Return parameter lt NR3 gt Unit current unit Example PMETLLIM 0 Set SENSe PMETer PSENsor MODE Description Sets or queries the power meter sensor mode Syntax SENSe PMETer PSENsor MODE LOW Noise FASTer Query Syntax SENSe PMETer PSENsor MODE Parameter LOWNoise Sets the power meter mode to low noise Return parameter FASTer Set the power meter mode to fast Example PMET PSEN MODE Set SENSe PMETer RECording TIME Description Sets or queries the power meter recording time 168 GW INSTEK REMOTE CONTROL Syntax SENSe PMETer RECording TIME lt hour gt lt minute gt lt second gt Query Syntax SENSe PMETer RECording TIME Parameter lt hour gt lt NR1 gt Recording time hours Return parameter minute lt NR1 gt Recording time minutes second lt NR1 gt Recording time seconds Example PMET REC TIME 1 10 30 Set SENSe PMETer RECording TIME STEP Description Sets or queries the power meter recording interval in seconds Syntax SENSe PMETer REC
159. xample CALC JITT TIME gt 5 31e 08 93 GW INSTEK GSP 9300 Programming Manual CALCulate LIMit n CLEar Set Description Clears the High Limit Low Limit and the Pass Fail state for the selected limit line Syntax CALCulate LIMit lt n gt CLEar Parameter lt n gt Selected limit line Example CALC LIMT CLE Set CALCulate LIMit lt n gt DATA Description Sets or queries the frequency amplitude limit of every point in the selected limit line The data is stored in CSV format There are total of 10 pairs of data points 20 data entries in total for the lt csv data gt data Syntax CALCulate LIMit lt n gt DATA csv data Query Syntax CALCulate LIMit lt n gt DATA Parameter csv data pt 1 freq pt 1 limit pt 10 freq Return parameter pt 10 limit n Seleted limit line Example CALCulate LIMit3 DATA 1e46 10 2e46 30 3e46 40 4e46 CALCulate LIMit FAIL Query Description Returns the Pass Fail judgment Query Syntax CALCulate LIMit FAIL Return parameter 0 Pass Fail Query Example CALC LIM FAIL gt GW INSTEK REMOTE CONTROL CALCulate LIMit LOW Set Description Selects which limit line is used for the low limit Syntax CALCulate LIMit LOW lt limit num gt Parameter lt limit NRI 1 5 num gt Example CALC LIM LOW 2 CALCulate LIMit HIGH Set Description Selects which
160. y MOVE src file name dest file name Parameter src file name dest file name 138 GW INSTEK REMOTE CONTROL Example MMEM MOVE Quick pg1 jpg Quick pg2 jpg MMEMory REName Set Description Renames the designated file from the current file Syntax MMEMory REName old file name new file name Parameter old file name new file name Example MMEM REN QuickJpgl jpg QuickJpg2 jpg MMEMory STORe CORRection Set Description Store correction data to a file from the internal memory Syntax MMEMory STOR CORRection corr num new dest file name Parameter corr num NRI correction set 1 5 new dest file name XXX cor Example MMEM STOR CORR 2 test cor MMEMory STORe LIMit Set Description Store limit line data to a file from the internal memory Syntax MMEMory STOR LIMit lim num new dest file name Parameter lim num NRI limit line 1 5 new dest file name XXX lim Example MMEM STOR LIM 2 test lim 139 GW INSTEK GSP 9300 Programming Manual MMEMory STORe PMETer Set Description Store power meter data to a file from the internal memory Syntax MMEMory STORe PMETer new dest file name Parameter new dest file name XXX pmet Example MMEM STOR PMET test pmet MMEMory STORe SCReen Set Description Store a screen shot to the current file directory Syntax