Home

BDP-1USB Owner`s Manual

image

Contents

1. hard drive pictured below and a USB DAC such as the BDA2 to the BDP 1USB Audio Connection Prior to powering your BDP 1USB on connect your BDP 1USB to your DAC using a cable with a USB A Type connector on the BDP 1USB end and the end specified by the DAC manufacturer on the other For a Bryston BDA that is a B Type connector USB A Type AES EBU 6666 Local Storage Connection Your BDP 1USB can accept most USB storage media including thumb drives buss powered hard drives and self powered hard drives Buss powered hard drives must be connected at the rear USB ports and the total power draw from the two rear ports combined cannot exceed 500mA Please check the literature that came with your hard drive to determine its power requirements if you have trouble with your drive The preferred disk format scheme for USB attached media is FAT32 HFS and EXT3 are supported as well NTFS is not recommended Network Connection Your BDP 1USB features a single 10 100 ethernet port designed to connect to your home network router to facilitate control via portable devices or computer and to obtain internet connection useful for streaming internet radio downloading firmware updates and if needed permit Bryston support personnel to acces the unit via service mode upon your request Use a CAT 5 CAT 5e or CAT6 patch cable to connect your BDP 1USB to an available ethernet port in your room or directl
2. contact Bryston for information on how to re flash your BDP 1USB s internal CF card If the error occurs upon the first boot sequence after connecting a new USB drive try removing the drive and restarting again If it boots with no If neither of these work contact Bryston for instructions on how to verify the integrity of the internal serial cable 10 11 Bryston Limited 677 Neal Drive Peterborough Ontario K9J 6X7 Canada Phone 705 742 5325 www bryston com 11 20 14
3. or higher date code format is yyww where yy is the two least significant digits of the year and ww is the week of the year must be accompanied by a copy of the bill of sale from a Bryston authorized dealer to qualify for warranty service The warranty is transferable from the original owner to a Subsequent owner as long as a copy of the bill of sale from the original authorized Bryston dealer accompanies the re sale The copy of the bill of sale to any subsequent owner need ONLY include the Name of the Bryston Authorized Dealer and the Model and Serial number of the Bryston product The warranty will only be honored in the country of the original purchase unless otherwise pre authorized by Bryston BRYSTON SERVICE in CANADA BRYSTON SERVICE in the USA BRYSTON SERVICE outside Canada and the USA Postal address PO BOX 2170 Stn Main 79 COVENTRY ST Suite 5 contact your local distributor or ne ai abel Maral CHECK OUR WEB SITE wwwbryston ca U S A 05855 E MAIL BRYSTON DIRECTLY cdnser bryston ca Courier address 677 NEAL DRIVE FAX BRYSTON DIRECTLY 01 705 742 0882 PETERBOROUGH ONTARIO PHONE 802 334 1201 PHONE BRYSTON DIRECTLY 01 705 742 5325 CANADA K9J 6X7 FAX 802 334 6658 PHONE 705 742 5325 E mail usaser bryston ca FAX 705 742 0882 E mail cdnser bryston ca SAFETY_INSTRUCTIONS_WARRANTY_CONTACT_SHEET_20120816 Table of Contents GONE Al ee eeeseecccesscccccsscceessscceessscceeeescens 4 WeElCOME acetic cen cep suns
4. to remotely power your BDP 1 on or off The control voltage is applied to the IN port will be routed to the OUT connector via an isolated relay after the BDP 1USB has fully powered up The remote trigger input takes precedence over the front panel push button e PREV NEXT eooo eooo 5 TRIGGER O switch When a valid control voltage is present at the IN port the unit cannot be powered off Navigation Keys Up A Down y Left lt and Right gt Use the Up and Down keys to step through a list of connected USB storage devices thumb drives hard drives and to scroll through menus and options Use Right and Left keys to select options and step backwards through the hierarchy respectively See Front Panel Menu Navigation on page 10 for the full menu tree When using these keys to initiate playback the Right key will open selected folders identified by a 7icon and will Play the selected track when a tile identified by the icon is selected Press the Play button when a drive folder or playlist is selected to play all files contained within Data Plate This label provides the unit s exact model number serial number electrical rating and STOP PAUSE PLAY e e MADE IN PETERBOROUGH ONTARIO CANADA B DRST BDP 1USB DIGITAL PLAYER DATE CODE REVISION DATA PLATE SERIAL NUMBER ELECTRICAL RATINGS IEC 320 C14 POWER INLET date
5. E INVESTIGATING POWER SUPPLY ISSUES DISCONNECT MAINS POWER FROM UNIT ERROR 04 AC Line voltage has momentarily sagged below threshold sufficient to maintain power to main board Minimum line voltage specs for 120V and 240V units are 100V and 190V respectively Simply rebooting the unit will clear this Toggle Show Hidden Toggle Basic Advanced Copies current playlist to selected disk voltage specs for 120V and 240V units are 128V and 254V respectively Simply rebooting the unit will clear this error presuming the faulty AC mains condition no longer exists error presuming the faulty AC mains condition no longer exists eee e ERROR 05 AC Line voltage has momentarily exceeded the high threshold the power supply can tolerate Maximum line bryston Reset network parameters to DHCP Enables Service Mode Note Service ID No Resets all user preferences to default problem contact Bryston for instructions on resolving the problem with your drive Scans CF card for integrity ERROR 09 This message occurs if the microprocessor doesn t hear from the main board running the main operating system This can happen if the firmware on the built in flash card becomes corrupted if the BDP is mistakenly trying to boot from an attached drive or in rare instances if the serial cable connecting the main board to the power supply is loose If the error occurs after a power failure failed firmware upgrade or other major system disruption
6. IRUS 2D pop 1use Owner s Manual IMPORTANT SAFETY INSTRUCTIONS The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of un insulated danger A ous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance Servicing instructions in the literature accompanying the product Read these instructions Keep these instructions Se Ot Oe o Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the pro vided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacl
7. LUE CAUTION RISK OF ELECTRIC SHOCK DO NOT OPE PRECAUTION RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR Front and Rear Panel 1 RS232 For connecting hard wired control systems like AMX Crestron Savant etc See Firmware User s Manual to enable USB Ports The BDP 1USB has four USB 2 0 ports two each on the front and back When connecting port powered USB drives use the rear ports Low a power draw or self powered devices like thumb drives and DACs can use either the front or rear The combined amperage draw from the two rear ports cannot exceed 500mA Infrared Sensor Receives control signals from IR remote controls such as the Bryston BR 2 to control basic transport operations play pause next etc Ethernet Port Cat 5 or later ethernet with RJ45 connector 6 E OO n m O 2 G ETHERNET standard ethernet network cable connects here to facilitate local network and internet connectivity for control via tablet smartphone and computer devices Port is 10 100 compatible Dot Matrix VFD Display Provides basic visual feedback when navigating menu or playing back music Remote Power ON OFF Trigger The BDP 1USB is equipped with two 3 5mm two conductor phone jacks for implementing a remote power On Off function Supplying a DC control voltage between 3 and 12 volts at greater than or equal to 1mA to the Trigger IN port will allow you
8. ailable trom Bryston Upon availability the Dashboard on the web interface will notify you To identify which version of firmware you are currently running you may either use the front panel or the web interface To determine the current version of the firmware from the front panel press the up A and left lt buttons to return to the home screen Then press the up amp button The example indicates that the firmware version is S2 04 2014 06 08 To discover your current firmware version from the Bryston Web Intertace please consult your Firmware User s Manual Display Brightness amp Auto Shutoff Your BDP 1USB is equipped with a very high quality VFD dot matrix display designed to operate without fail for many years To adjust its brightness and configure its automatic shutoff feature press A and Gin rapid succession by sliding your finger across them Use the up A and down Y buttons to switch between setting the brightness from 1 to 4 and the time delay from always ON 10 seconds 1 minute 5 minutes OFF using the lett lt and right gt buttons The menu will disappear approximately 10 seconds after the last button press and settings will be saved IDESH ppp 1use RESTOR BDP 1USB DIGITAL PLAYER ATTENTION UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE ET VALEUR DEBRANCHER AVANT DE REMPLACER LE FUSIBLE CAUTION DISCONNECT SUPPLY a CORD BEFORE REPLACING FUSE WITH SAME TYPE AND VA
9. entednacvndwarssstnteteeseatsasnes 4 FOO WURCS consveeccavesenesasssuahosasossetannsoaienceucssassses 4 Power Considerations cccccessescceesseceeeee 5 Fuses amp Electrical Safety cccsssssccceeeees 5 Firmware UPCates ssscccseeceececceeeeeeeees 5 Display Brightness amp Auto Shutoff 5 Front and Rear Panel eeeeccceeseeceeeee 6 I ts 7c erii 6 2 U BPOS enics mien naa 6 3 Infrared Sensor ssssessssesssssseses 6 4 Ethernet Port wciscecsesvesncsvtvisssastwone 6 5 Dot Matrix VFD Display 0066 6 6 Remote Power ON OFF Trigger 6 T Navigation eG are eee eee T 8 Data Plate svassssecstereceriertvensssciwones 7 9 Transport Function Keys I 10 Power Button amp LED Indicator T 11 IEC Power Inlet essensen T Connecting To Your SystemM see 8 Audio COnnectiOn sssssssssssersssesssscesssseses 8 Local Storage Connection eeeeeeeeesssssssss 8 Network Connection ccecccccsssecceeeseceeeee 8 Wireless Bridge wecmerasrunvendeaparvereonmmeneuanevcens 9 DiMenSIOnS sesssssssessesssessessscessesserseeeseesees 9 Front Panel Menu Navigation 6 10 Error CodeS sssssssssesssseessssessssersssesssssesss 10 3a 7STLICOLD epp 1use General O OZO O OOOO O OO Welcome Thank you for your purchase of a Bryston BDP 1USB a state of the art digital music player that can play back the vast majority of digital mus
10. es and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over e 13 Unplug this apparatus when moving it amp during lightning storms or when unused for long periods of time A2 14 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE DO NOT EXPOSE THIS EQUIPMENT TO DRIPPING OR SPLASHING AND ENSURE THAT NO OBJECTS FILLED WITH LIQUIDS SUCH AS VASES ARE PLACED ON THE EQUIPMENT TO COMPLETELY DISCONNECT THIS EQUIPMENT FROM THE AC MAINS DISCONNECT THE POWER SUPPLY CORD PLUG FROM THE AC RECEPTACLE THE MAINS PLUG OF THE POWER SUPPLY CORD SHALL REMAIN READILY OPERABLE UNPLUG MAINS CORD DURING TRANSPORTATION BRYSTON LIMITED WARRANTY Bryston analog audio circuits are warranted to be free from manufacturing defects for twenty 20 years from the original date of manufacture The warranty i
11. ic file formats including today s most popular lossless codecs including AIFF FLAC WAVE APPLE LOSSLESS and more at resolutions up to 192kHz 24 bit PCM and up to DSD 128 into compatible USB DACs Music stored on both locally attached USB media and network attached storage NAS devices is aggregated and indexed into a single library The BDP 1USB includes intuitive software for controlling your BDP that requires no installation and is accessible from any modern web browser A wide variety of compatible third party applications are also available for iOS and Android mobile devices In stand alone systems the BDP 1USB can also be controlled via front panel buttons and the 2 line dot matrix display or with our optional BR 2 IR remote control Integration with whole house control systems is also possible using the provided RS 232 connector We have designed the BDP 1USB to provide the highest sound quality possible and an enjoyable user experience free from the hassles normally associated with computer based audio playback A Quick Start Guide has been provided to help you setup and play music right away This manual provides a technical reference for hardware setup interconnectivity warranty and safety Bryston stands committed to ongoing improvement and software development For that reason we have separated the Firmware User s Manual in which you ll find detailed information on day to day use from this document See www b
12. less Bridge Ifyou do not have easy access to an ethernet connection in your listening room you may purchase an after market wireless bridge from most computer electronics stores Contact Bryston for further information as needed TELU 10 860 Side view with C series dress panel Side view with Rack mount dress panel O m O n Lr LA C N N oN UI p a i N O N O N U1 ul N O O 4 re NI NI Rubber Ul Rubber Ul Ln Foot e O oO Foot a oO 1606 1606 N k J aAISTICLD BDP 1USB Front Panel Menu Navigation Firmware Version Press the play key to instantly play the selected disk folder or track Subject to playlist length limit A second ethernet port is only available on the Address BDP 2 Toggle On Off Toggle On Off Use A eond aes Playback Stopped Toggle On Off arrows to lt navigate i Currently Playing menu Brief Description of 3 Toggle On Off ii Music Library Updating Clears Playlist Updates Music Library Error Codes Your BDP 1USB may display an error code in certain power line disruption events or if there is a problem booting The following is a brief description of each ERROR 03 Microprocessor does not detect voltage on main Analog Power Supply perhaps due to blown fuse faulty power supply wiring harness BEFOR
13. ncludes parts and labour Bryston Digital circuits and cables are warranted for five years from the original date of manufacture The warranty includes parts and labour Bryston products having motorized moving parts excluding motorized volume controls are warranted for three years from the original date of manu facture The warranty includes parts and labour Bryston will remedy the problem by repair or replacement as we deem necessary to restore the product to full performance Bryston will pay only return shipping costs for the full length of the specific products warranty In the event of a defect or malfunction contact Bryston s repair centers for return authorization Products must be returned using original packaging material only Packing material may be purchased from Bryston if necessary This warranty is considered void if the defect malfunction or failure of the product or any component part was caused by damage not resulting from a defect or malfunction or abuse while in the possession of the customer Tampering by persons other than factory authorized service personnel or failure to fully comply with Bryston operating instructions voids the warranty This warranty gives you specific legal rights and you may also have other rights which may vary from province to province and country to country As of 2006 02 22 Bryston will only warranty Bryston products purchased through authorized Bryston dealers Bryston products with a date code of 0608
14. nded line cord you can reduce the possibility of local ground loops which could cause hum or noise in the system by plugging its line cord into the same wall outlet next to the power amp and other equipment in your system Fuses amp Electrical Safety The BDP 1USB contains two 5x20mm cylindrical glass fuses One is for the standby power supply and one is for the main linear power supply If it should become necessary to replace either we recommend that you seek the assistance of qualified service personnel If you decide to change the fuse yourself we advise the following 1 Turn off the BDP 1USB 2 Disconnect ALL cables from the rear of the BDP 1USB especially the power cord 3 Remove all 10 screws securing the top cover to the chassis using a Torx T8 driver and remove the top cover 4 Locate the 5x20mm glass fuses on the power supply board near the IEC power inlet Replace blown fuses only with the same type and value All fuses are rated at 250V and are slow acting time lag types Refer to the fuse label inside the unit for the exact replacement value 5 Replace the top cover and all screws and reconnect all cables before reconnecting the unit to AC power and turning it back on MAINS STANDBY FUSE VOLTAGE 250 218 250 500 218 500 500 218 500 120 250 218 250 315 218 315 218 315 230 230 345 218 315 315 210 315 Firmware Updates BDP 1USB firmware updates will periodically become av
15. of manufacture Do not remove 9 Transport Function Keys Play Pause Stop Previous and Next function in essentially the same manner as they would on a CD player Next and Previous skip ahead or behind the currently queued track in the playlist 10 Power Button amp LED Indicator When the LED above the power switch is lit red the unit is in standby When it is green the unit is fully powered up If your unit is equipped with an optional blue red LED blue represents the power on state 11 IEC Power Inlet The IEC 320 C14 power inlet accepts IEC 320 C13 equipped power cords such as the unit provided Use only appropriate power cords that have been approved for your region ONRUST pop 1use Connecting To Your System The BDP 1USB is designed for the explicit purposes of playing back your digital music library in a bit perfect manner As a very precisely engineered digital audio device sound quality can vary based on the digital to analog converter to which it is connected A high quality converter such as those offered by Bryston are recommended Compatible digital to analog converters will have USB inputs that are USB Audio Class 2 0 Compliant No other digital outputs are provided The BDP 1USB also requires that you store and organize your music library on a connected USB drive and or via network attached storage Thus the minimum hookup requirements include attaching a music storage device like the portable
16. ryston com for the most current edition Again thank you for choosing Bryston Features Extensive technical research and development has been undertaken to ensure the highest quality playback and durability of your BDP 1USB The following details describe some of these features e Linear power supply for audio processing circuitry e Aseparate power supply for microprocessors and for maintaining standby mode e Four USB 2 0 backwards compatible with USB 1 1 and 1 0 specifications ports e Wide variety of control options including e Front panel push button controls e Responsive web interface compatible with iOS Android Macintosh and windows devices e Third party app compatibility with diverse software such as MPoD and MPaD for iOS and MPDroid for Android e IR Remote control such as Bryston s BR 2 or other universal remote controls e RS 232 2 way control Interconnectivity with USB Class 2 0 digital to analog converters including those that support DSD over PCM DoP e Extensive compatibility with different music file formats See current firmware manual for details e User upgradeable firmware e Remote 12 Volt On OF trigger IN amp OUT via 3 5mm 2 conductor phono jacks e Compatible with USB hard disk and solid state storage media as well as network attached storage e Cosmetic unity with other Bryston products Power Considerations In general if your BDP 1USB has a three prong grou
17. y to your home router Successful network connection will be indicated by green and amber LEDs lighting on the BDP 1USB ethernet port and by assignment of an IP address M TRIGGER IN OUT romo O AICS TCDC 804 2 D A CONVERTER OPTO 2 OPTO 1 YN SPDIF 3 SPDIF 2 SPDIF 1 PEN TRIGGER meL A A C 320 014 PRECAUTION POWER INLET SOW CE CHOC ELECTRODE NE PAS OUR by the router View the IP address on the front panel by pressing the Down V key Your IP Address begins after eth0 You can use this IP address to access the Bryston Web Interface trom any web enabled device on the same local network as the BDP 1USB Enter the IP address in your web browser s address bar Also any device running the Bonjour service will respond to the URL http bryston bdp 1 local instead of the IP address All Macintosh computers and iOS have this service built in Windows computers can run this service once downloaded trom the Apple website Android devices do not currently support Bonjour and must use the numerical IP address Since virtually all modern routers assign IP addresses to client devices this IP address may periodically change which can be a nuissance To fix your BDP 1USB s IP address either invoke the 11 410 l 10 860 a DHCP reservation function in your router or simply set a Static IP address in Bryston Web Interface Instructions on how to do so are located in the Firmware User s Manual Wire

Download Pdf Manuals

image

Related Search

Related Contents

View a product catalog[PDF/2.6 MB]  Blue Ox Patriot Braking System Installation  Timpdon Electronics Crossing Controller Model XC1 User Manual  LSM.Connect 02.02 User manual  US Instructions  Stellaris® LM4F120 LaunchPad Evaluation Kit User`s Manual (Rev. A)  MOBILE POWER SUPPLY - Lidl Service Website  Austin Hughes Electronics Ltd CBC-6 keyboard video mouse (KVM) cable  

Copyright © All rights reserved.
Failed to retrieve file