Home

SPECIFICATION SHEET lumentouch™

image

Contents

1. reserves the right to make changes to this product at any time without prior notice EM R12 and such modification shall be effective immediately Sustainable architectural LED lighting systems SPECIFICATION SHEET INSTALLATION 3 5 2013 05 15 EM R12 1 Mount an electrical box inside the wall electrical backbox If you use a double size box you can insert the power supply inside 2 Connect the wires DMX Connect the DMX cable to the lighting for XLR 1 ground 2 dmx 3 dmx POWER Connect a 9V DC 0 65A Secondly plug the 2 connectors see blue arrow Then close the interface using one screw The S T I C K controller can be installed in any standard receivers Leds Dimmers Fixtures a Be sure to not invert the and the ground lumentouch PORT 1 2 3 4 If your application need to have some external contact closures make the contacts between the ground and the ports 3 Mount the interface on the wall First mount the back side of the interface on the wall with 2 or more screws Lumenpulse 1751 Richardson Suite 1505 Montreal Quebec Canada H3K 1G6 1 877 937 3003 P 514 937 3003 F 514 937 6289 into lumenpulse com www lumenpulse com Copyright 2013 Lumenpulse Lumenpulse reserves the right to make changes to this product at any time without prior notice and such modification shall be effective immediately lumenpulse Sustainable architectural LED lighting sy
2. 6 1 877 937 3003 P 514 937 3003 F 514 937 6289 i info lumenpulse com www lumenpulse com Copyright 2013 Lumenpulse 2013 05 15 Lumenpulse reserves the right to make changes to this product at any time without prior notice EM R12 and such modification shall be effective immediately Sustainable architectural LED lighting systems SPECIFICATION SHEET _lumentouch PROGRAMMING Some functions are available directly from the STICK keypad using the SELECT button Ay WARNING Fr 3 30pm 15 30 1530 lumentouch A B C D E dimmer O speed O select Q color 9 DEC 2008 ooeec 5 DEC a gt 051208 lumenpulse Exar ple view 2 45pm a 4 45 a 1445 ser e 1 View time 1445 2 45pm USA or 14 45 Europe Example view 6 SEP 2009 date 060999 suer 2 View date 060909 September 6th 2009 Example set 3 30pm 15 30 1530 SELECT FF 3 set time t S gt 1 1530 Example set 5 DEC 27008 date 051770 were 4 Setdate 0 5 4 2 0 8 051208 5 Set Fade SELECT 0132 ll Example assign an IR key to Scene 2 SELECT 9 Set IR 2 view 1 02 firmware versi n 0107 _ a Firmware sect O En version 0102 firmware version 1 072 5 5 Lumenpulse 1751 Richardson Suite 1505 Montreal Quebec Canada H3K 1G6 1 877 937 3003 P 514 937 3003 F 514 937 6289 i info l
3. SPECIFICATION SHEET Client lumentouch Project name Order lype FEATURES AND BENEFITS e Flat wall mounted lighting controller e Universal mounting plate compatible with any electrical backbox e MINIUSB connection for software programming e Can be used without a computer in stand alone mode e Touch sensitive control panel e 2 DMX universes 1024 channels Unlimited memory via Micro SDCARD e Integrated clock calendar e RS 232 serial and I O ports e Universal infrared receiver Standard with ETHERNET card e lumentouch is supplied with the Lumenstudio programming software PACKAGE CONTENT e lumentouch hardware stand alone wall mounted DMX controller e User manual e Mini USB cable e Micro SDCARD and adapter 9V DC power supply 1 20 240V AC input voltage with connector block for DMX connection Compatible with Windows XP VISTA and 7 32 bit or 64 bit HOW TO ORDER LTO Housing 1 Qty Universal back mounting plate Hole pattern to fit most standard junction boxes Please remove protective film before use to ensure proper operation of the controller 1 5 Lumenpulse 1751 Richardson Suite 1505 Montreal Quebec Canada H3K 1G6 1 877 937 3003 P 514 937 3003 F 514 937 6289 into lumenpulse com www lumenpulse com Copyright 2013 Lumenpulse 2013 05 15 Lumenpulse reserves the right to make changes to this at any time
4. stems SPECIFICATION SHEET lumentouch EXTENSION CONNECTORS 2x10 pins EXTENSION connector P3 You can easily RS232 TX a L OND DMX RS RX l 2 mxi TEP ACE DME PORT z Ug L L DMXI CHIPS PORTS 7 s puxa PORTS la a DMX PORTS 12 _ Relay DMX PORTS MEER universe 2 Port 15 16 oND a M PORTO 19 99 VIN DMX 7 universe 1 PORTS 1 to 8 make contacts Ref between G GND and P1 P8 SP485ECP L MAX485CPA BLACKOUT relay energy save using the 2 pins BK and G GND el gt Sc es RS232 triggering The command string for selecting scenes is 01 XX FF where XX equals the scene number with 2 digits So to select scene 01 which is Page A scene 1 the string is 0101FF To select scene 11 which is Page B scene 3 the string is 0111FF Notes RS232 triggering is only for selecting playing scenes on the LTO The scenes you want to select play must be programmed to the buttons on the LTO The RS232 triggering must be enabled checked ON in LTPO Hardware Tools under Parameters The RS232 connections must be landed on the LTO via the COM Plus or External LTO Connector The TX and RX must be crossed over aka TX to RX and RX to TX Ground still goes to Ground All command strings must be sent as HEX values Com settings are 9600 baud 8 bit 2 stop bits no parity no hardware flow 4 5 Lumenpulse 1751 Richardson Suite 1505 Montreal Quebec Canada H3K 1G
5. umenpulse com www lumenpulse com Copyright 2013 Lumenpulse 2013 05 15 Lumenpulse reserves the right to make changes to this product at any time without prior notice EM R12 and such modification shall be effective immediately Sustainable architectural LED lighting systems
6. without prior notice e ctive immediately EM R12 and such modification shall be ef lumenpulse Sustainable architectural LED lighting systems SPECIFICATION SHEET lumentouch CONNECTIONS 128 mm A Touch sensitive s user interface Extension socket rear connectors 2x10 pins Ethernet socket RJ45 168 mm Screw terminal rear connector 9 pins Front access I a m connections open cover OO O E e k a 11 5 mm solvers tumens CSCS Dimensions 168x128x11 5 mm Complete package 25015055 mm Weight 0 2k9 044 bs Compete package 06kg 1321s reset mini power on off micro data button USB led switch sdcard led screw terminal extension socket front access S pP E C F l C ATI O N S C O N N E CT O N S bane rear connector rear connectors connections 9 pins 2x10 pins open cover 4 Contact closure inputs connect to ground for operating Ports 5 6 7 8 4 Contact closure inputs connect to ground for operating Advanced networking features User interface 14 buttons 1 fader 28 leds Touch sensitive keypad ied power data leds Infrared receiver Easy learning triggering from any 36Khz remote control 2 5 Lumenpulse 1751 Richardson Suite 1505 Montreal Quebec Canada H3K 1G6 1 877 937 3003 P 514 937 3003 F 514 937 6289 into lumenpulse com www lumenpulse com Copyright 2013 Lumenpulse 2013 05 15 Lumenpulse