1. Page 16 GardTec 595 Programming Time amp Date 1 10 11 With the display showing Enter a Master Code the display will show Press NO six times the display will show Press YES the display will show Press YES for Auto Adjust for British Summer Time the display will show Press NO to change display will show Enter the last two digits of the Year then press YES Display will show Press YES Display will show Enter the Date in the form dd mm followed by YES Display will show Enter the Time using the 24Hr Clock format then YES Display will show Press 0 to return to Unset Page 17 User Manual 01 JAN 18 58 01 Do you want to SET the System Do you want to Set DATE TIME Summer Adjust is On ok Year is 2004 ok Enter Year 20 Then YES Year is 2005 ok Enter Day Month Then YES Enter Hrs Mins Then YES Do you want to Set Date Time User Manual GardTec 595 Vo Comm if fitted Vo Comm is a method of transmitting signals to a standard land line or mobile telephone giving information regarding the status of your security system This may be in addition to or instead of central station communications It should be noted that Vo Comm should not under any circumstances be u
2. Anti Code 1234 Can t Set use Anti Code 1234 GardTec 595 User Manual 7 To reset the system with an Anti Code contact the central station or engineer as instructed by the installation company and quote the number given by the display 8 The central station or engineer will give a return Anti Code this may contain the YES amp NO keys for example 5 YES 2 4 9 Enter this Anti Code into the keypad 10 The system is now reset Page 25 User Manual GardTec 595 Setting Engineer Authorisation A User Code may be required to authorise an engineer to gain access to the system in the event of service or maintenance schedules The level of User Code required to authorise the engineer to access the system is set within the User Menu that is accessed via a Master Level Code Setting the Engineer Authorisation Level 1 Enter a Master User Code The display will Do you want to show SET the System 2 Press NO until the display shows Do you want to Then press YES Authorise Engnr 3 Press NO until the required setting is displayed Engnr Authorisor Any Master Main and Any are user code levels If None is selected no user authorisation will be required to grant engineer access to the alarm system 4 Press YES The display will show Engineer Access This option is dealt with later is Off Ok
3. For more details on Vo Comm please refer to the Vo Comm section Press NO until the setting you require is displayed YES or NO Then press Yes Note The Vo Comm will need to be programmed in order for this option to work please refer to the Vo Comm section in this manual User31 Name 10 The display will show for example Rod 11 If you wish to accept the User Name shown press YES and jump to step 15 Or If you wish to change the User Name shown press User 1 Name NO the display will show a 12 You may now enter up to nine characters for the user name using the layout shown below for the allocation of characters f l ABC DEF GHI I l TED Ca STU VWX YZ NO Co te l User Manual GardTec 595 13 14 15 16 Referring to the character map enter the required character pressing the 3 key will display G pressing it again will show H and again will show I once the correct character is displayed press YES and the display will move on to the next position Continue entering characters up to 9 If you require a blank space press YES while the is displayed As you press YES for the ninth character or if you have jumped from step 11 the display will change to Do you want to Prog USER CODES If you wish to program other User Codes return to step 4 Or Press 0 to return to 01 JAN 18 58 01
4. are available for viewing Page 23 User Manual 8 Press the YES key to view the next event and carry on to view any others if present When viewing the last event the display will show for example GardTec 595 Zone 005 TAMPER 01 JAN 18 58 01 lt The left arrow now indicates that you are at the end of events The NO key may be used to scroll back the opposite way Re setting the system 1 If the system is programmed for Any code reset enter a User code The display will show Note If NO is NOT pressed then the alarm status will only be displayed for ten seconds The display will then show Enter your user code again The display will show Press YES The exit tone will sound and the display will show for example Enter the code again to abort the setting The system is now reset Or If a higher level of code is required one of the following displays will be shown Use a Master code to reset the system Or Call the installation company Or Call the central station or installation company as instructed and quote the number given Or Page 24 lt lt lt lt ALARM gt gt gt gt Press NO to view Enter Code 1 Check Do you want to SET the System EXIT 1 All Zones ON 15 Can t Set use Master Can t Set use Eng Code Can t Set use Eng
5. As areas are turned off they will be removed from the display Exit the premises or retire to an un protected area as detectors are violated the continuous exit tone will change Areas must first be programmed by the installation company before they will appear on the display Area Setting using Area codes Area codes are only effective to their own area with the exception of the cleaner area This may be turned off by an area code only if all areas are in the unset condition Use is the same as Setting the system shown on page 5 but only the relevant area will be set Page 8 GardTec 595 Removing Zones Master amp Main codes only User Manual If programmed by the installation company individual zones may be removed this may only be done by a Master or Main level of code It should be noted that if an Area Main code is being used only zones associated with that area may be removed 1 With the display showing 2 Enter a Master or Main level code the display will show 3 Press NO the display will show 4 Press YES the display will show 5 Enter the zone number you wish to remove followed by YES pressing NO will un remove a zone the display will show 6 Repeat step 5 until you have removed all the required zones 7 Press 0 to escape the display will show 8 Press YES the continuous exit tone will sound 9 Exit the premises via the authorised exit route the exit tone w
6. with that code Setting an unset system with a cleaner code will set the full system Unsetting The System 1 2 3 Note Note Note Enter the premises via the authorised entry route the broken entry tone will sound Proceed to the keypad enter a valid User code the display will show Un The system is now Unset After 10 seconds the display will show If an area code has been entered only the area associated with that code will be Unset If a cleaner code has been entered only the cleaner area will be Unset In the event of the system being set using ACE when the battery is low the display will show Ab when the system is unset Press NO to clear the display and then change the battery in the Keyfob Page 31 User Manual GardTec 595 Part Setting The System using Master amp Main type codes 1 2 Note Note With the display showing Enter a Master or Main type code The display will show SE flashing Press 1 2 or 3 for Part 1 2 or 3 the display will show the E and The two bottom bars if Part 1 has been selected The top and bottom bars if Part 2 has been selected The bottom bar only if Part 3 has been selected If a Global code Master or Main has been used all areas that are being set would be Part Set If an Area Main code has been used only the Part Set associated with that area would be Part Set The exit tone may or may not be heard dependa
7. 37 that some of the user numbers on your system have been reserved you should not use them whilst programming user codes If you do so your system may be adversely affected 1 With the display showing FeSP Sowing 01 JAN 18 58 01 i F ag Do you want to 2 Enter a Master Code the display will show SET the System 3 Press NO five times the display will show Do you want to Prog USER CODES 4 Press YES the display will show Enter User No 1 31 Then YES 5 Enter the user number 1 to 31 that you wish to program followed by YES the display will show Now Enter Code Then YES 6 Either Enter the User Code you require followed by YES If you wish to Delete a Code enter six Zeros followed by YES Or Present your G Tag to the Reader Code Type The display will show Master ok Page 14 GardTec 595 User Manual 7 Press NO until the Code Type you require is eo de ode Group displayed then press YES Display will show Nne OE 8 Code Groups are only used in conjunction with controlling outputs This is dealt with in the Advanced Code Programming section page 39 of this manual Press YES to accept None 9 The display will show VoComm Trigger This determines if using this user code to Set or GRISES Unset the system will trigger the Vo Comm
8. Master or Main type code Can t Set Check has been used 4 Then press YES The display will show EXIT 1 Note The display will switch between the EXIT display and All Zones ON 15 the Power Cut FAULT display as the time counts down Page 28 GardTec 595 5 6 Exit the premises via the authorised exit route Once the premises are secure listen from outside User Manual the protected area and wait until the exit tone finishes before leaving Re setting the display after a Mains Fail Note In the event of a Mains Power Failure the control panel will display that a fault has occurred if the pre programmed time has been exceeded In the event of a mains power failure the display will show Enter your User code The display will show Enter I I Check Code Power Cut 01 JAN 18 58 01 gt FAULT The right arrow is now indicating that more events are available for viewing Press the YES key to view the next event and carry on to view any others When viewing the last event the display will show for example Mains Ok Ack 01 JAN 18 58 01 lt The left arrow now indicates that you are at the end of events The NO key may be used to scroll back the opposite way Enter your User code again The display will then show Followed by YES if a Master or Main type code has been used Enter the code aga
9. Set 1 2 3 1 one No Example E E 182 Page 37 User Manual GardTec 595 System G Tag G Tag Readers are available in three variants with the reader built into the display area of an LCD RKP as an Internal Stand alone Reader or as an External Stand alone Reader When using G Tag the system may be Set Unset by presenting a valid Tag to one of the Readers Each Tag is programmed onto the system as an individual User Code therefore giving indication via the system Log of who has set and unset the system As the Tags are a close proximity device the risk of code capture is eliminated When programming the G Tags follow the normal Programming Codes instructions to the point when you are asked for the Code for example Now Enter Code Then YES At this point present your G Tag to the reader and the code will be entered If you have more than one reader on your system the G Tag MUST be programmed onto each of the readers on the same User Number Because of this it is essential that you use good housekeeping for the G Tags Mark each of the G Tags and record what User Number the G Tag has been allocated to The readers will be allocated to a specific keypad The G Tag information is stored in the keypad therefore a single keypad having two readers would only require the G Tag to be programmed into one of its readers For multiple keypads with readers the sequence for programming the G Tags would
10. has an Area or Areas already Set you may add more Area s as required 1 With the display showing for example Area 1 is already Set 01 JAN 18 58 01 2 Enter a Group Master or Group Main level RESET oe Code Display will show Set Area s 3 Press YES Display will show SSLALL ATOA 4 If you Press YES all the remaining Areas allocated to Code will be Set Or Set If you Press NO Display will show Cros GS 5 In this example use the 2 or 3 key to add Area s 2 or 3 to the system Set 6 When you are happy with your selection Press YES The Exit sounder will sound then lt lt SET13 the display will show for example 01 JAN 18 58 01 In this example Area 3 has been added to the Set 7 After 10 seconds the display will show 01 JAN 18 58 01 Page 48 GardTec 595 User Manual Display Blanking Dependant on the level of your system and the legislation that it is required to comply with your installation company may have initialised Display Blanking When this is used the Status of the system will only be indicated on the display for ten seconds after it has been Set and for ten seconds after it has been Unset The Status of the system may be shown by following the procedure below Please note Control Codes or Group codes cannot be used for this feature 1 W
11. of a selected group of areas Group Area Codes are classed as an Advanced User Function as they allow for greater flexibility on systems that are using multiple areas For details on using Group Area Codes please refer to the section Advanced Setting and Unsetting Using Group Area Codes on page 42 Control Code Levels affecting an output Control Allows an output that has been pre programmed by the installation company to be operated May also have an attribute of Can or Can t Unset Control level codes can never Set a system Page 4 GardTec 595 User Manual Setting The System 1 With the display showing 01 JAN 18 58 01 2 Enter your User code Followed by YES if a Master or Main type code has been used The display will show ie 1 i ones ON 15 and a continuous exit tone will sound See Pre Exit Check note below Time will count down Note Count down in display is dependant on the setting mode programmed by the Engineer 3 Exit the premises via the authorised exit route The exit tone will change if any detectors are violated during exit 4 Once the premises are secure listen from outside the protected area that the exit tone returns to the continuous tone 5 Wait until the exit tone finishes before leaving Note Setting the system with an area code will set only the area s associated with that code Note Setting an unset system with a clean
12. to escape Pressing 6 will silence the internal sounder Pressing 4 will toggle the Strobe On Off Pressing 9 will toggle the Bell On Off Page 10 GardTec 595 9 10 Whilst in Test mode any zones violated will sound the internal sounder if it has not been silenced and show on the display When you have finished testing the system press 0 twice the display will show Viewing The Event Log Master code only 1 With the display showing Enter a Master Code the display will show for example Press NO three times the display will show Press YES the display will show for example Page 11 User Manual 01 JAN 18 58 01 01 JAN 18 58 01 SET the System Do you want to Do you want to View the LOG Read Log 01 JAN 18 58 01 User Manual GardTec 595 5 This is the most recent event in the log Whilst viewing the Log Pressing NO will move back to the previous event Pressing YES will move forward to the next event Pressing 7 will take you to back to the last event of the previous day Pressing 9 will take you forward to the first event of the next day Whilst viewing a zone descriptor pressing 5 will show the zone number When you have finished viewing the Log press 0 twice the display will show 01 JAN 18 58 01 Changing The Chime Status Master code on
13. 5 Press YES The display will show Do you want to Authorise Engnr 6 Press 0 to return to 01 JAN 18 58 01 Using Engineer Authorisation A valid Authorisor code will be required to give an engineer access to the alarm system This may be done in two ways 1 The engineer will enter his her code The display Enter Authorisor will show Code 2 Enter a valid level of User code to grant the engineer access Page 26 GardTec 595 User Manual Or D tto 1 Enter a Master User code The display will show SET the System 2 2 Press NO until the display shows Do you want to Authorise Engnr 3 Press YES The display will show for example ry Authonsor Engineer Access 4 Press YES The display will show is Off Ok y r Engineer Access 5 Press NO The display will show is On Ok D tto 6 Press YES The display will show Ahotie Enda 7 Press 0 to return to Sno erodi Provided that the next code entered is a valid engineer code access will be granted to him her without further user intervention Page 27 User Manual GardTec 595 Mains Failure F Il Enter Code In the event of a Mains Power Failure the display will show ILII Check At this point the system will revert to battery back up The battery will only hav
14. Assigned Area s 123C ok Code Group None ok User Manual GardTec 595 10 This determines if using this user code to E set the system will trigger the Vo Comm xo amo a For more details on Vo Comm please refer to the Vo Comm section Press NO until the setting you require is displayed YES or NO Then press Yes Note The Vo Comm will need to be programmed in order for this option to work please refer to the Vo Comm section in this manual 11 If you wish to accept the User Name shown press User 02 Name YES and jump to step 16 User 02 Or If you wish to change the User Name shown press User 1 Name NO the display will show gt 12 You may now enter up to nine characters for the user name using the layout shown below for the allocation of characters STU VWX YZ 0 9 HA an ia pa at i ee a pa A a i S a aa a a aa iaa a a a J 13 Referring to the character map enter the required character pressing the 3 key will display G pressing it again will show H and again will show I once the correct character is displayed press YES and the display will move on to the next position 14 Continue entering characters up to 9 If you require a blank space press YES while the is displayed Page 44 GardTec 595 15 16 As you press YES for the ninth character or if you have jumped from step 11 the
15. RISC Creating Security Solutions 9 y With Cove 595 Control Panel LCD User Instructions amp LED User Instructions GardTec 595 Contents User Information Using LCD Keypads Introduction is serioa heat User Code Types Setting The System 0 0 eeeceeseescesseeeneeseaeeeeeteaeeeaeetaas Setting Unsetting via Keyswitch Unsetting The System 0 ceceecesseeeeeeeeeeeeeneeeeeeeeeeeaas Part Setting The System Quick Part Setting Area Setting eteesi inn anaes de REMOVING Zones Testing The System Viewing The Event Log Changing The Chime Status Programming User Codes c cccecceeseeeeeeeeeeeeeeeeeetees Programming Time amp Date eerren Vo Comm if fitted Using Vo Comm ceceeeceeeeeteees Messages From Vo Comm User Initiating Remote Access Optional Resetting After An Alarm eecceesereeesnereeeseeeeeneeeeee Setting Engineer Authorisation Setting The System With Mains Fail Re setting the Display After a Mains Fail Setting the System With a Line Fault Using LED Keypads Setting The System 0 0 eeceeceeeeeeeeeeneeeeeeeneeeeeeeeetaas U
16. be 1 Enter User Programming Mode 2 Choose what User Number you are using in this case User 2 for G Tag A 3 Program G Tag A onto the first reader 4 At the next Keypad re enter User Programming Mode 5 Choose the same User Number 2 6 Program the same G Tag A onto the second reader 7 Keep repeating until your G Tag A is programmed onto all readers 8 Now move on to G Tag B on User Number 3 Remember to mark your G Tags Page 38 GardTec 595 User Manual Advanced Code Programming Control Codes Codes may be programmed to control Outputs and Unset the system The Outputs that may be controlled will have been pre programmed by your installation company and may not be changed by the user Master user however does have the ability to allocate the codes not User No 1 to these Group Outputs 1 With the display showing 01 JAN 18 58 01 2 Enter a Master Code the display may show Do you want to SET the System 3 Press NO five times the display will show Do USER CAES 2 4 Press YES the display will show Enter User No 1 31 Then YES 5 Enter the user number 1 to 31 that you wish to program followed by YES the Now Enter Code display will show Then YES 6 Either enter the User Code you require followed by YES Or Present your G Tag to the Reader The display will show Code Type Master o
17. d be noted that if an Area Main code is being used only zones associated with that area may be removed 1 With the display showing Enter a Master or Main level code 2 The display will show SE flashing press NO 3 The Display will show F E flashing press YES 4 The display will show r 5 Enter the zone number you wish to remove followed by YES 6 The display will show r 7 If you wish to remove other zones return to step 5 Or To escape press 0 the display will show SE flashing 8 Press YES to start setting the system 9 Exit the premises or retire to an unprotected part of the system At the end of the exit time the exit tone will stop provided the system was clear Note Zone remove is only effective for the one set Page 33 User Manual GardTec 595 Setting the system with Mains Fail In the event of a short term power cut where it is known when power will be restored e g Engineers working on power lines that affect your premises it might be necessary to set this system Please follow the steps outlined below With the display showing Enter the User Code The display will show PC In the event of a mains power failure the control panel will display that a fault has occurred if the pre programmed time has been exceeded Enter your User code again Followed by YES if a Master or Main type code has been used Then press YES again Note The display will switch bet
18. display will change to If you wish to program other User Codes return to step 4 Or Press 0 to return to Page 45 User Manual Do you want to Prog USER CODES 01 JAN 18 58 01 User Manual GardTec 595 Setting Using Group Master amp Group Main Codes Group Master amp Group Main codes follow global Master amp Main codes with respect to the level functionality The difference lies in the ability to have individual control of the Areas that been allocated to the code 1 With the display showing 01 JAN 18 58 01 2 Enter a Group Master or a Group Main Code Do VOU WanttS 2e Display will show SET the System 3 Press YES Display will show Set ALL Areas If you Press YES the system will start to Set all the Areas that have been allocated to this Code Or If you Press NO the display will show Set The Areas shown will differ dependant on what Off 123 Ok Areas have been allocated to your Code The Top line shows the Areas that are Set and the Bottom line shows the Areas that are Off Unset Use the 1 2 3 amp 0 0 for cleaner Area to toggle the Areas between the Top amp Bottom line When you have finished the display may PRE show for example Of 2 Ok In this example Areas 1 amp 3 will be Set but Area 2 will remain Off Unset 4 Press YES The sy
19. e a limited time that it can sustain the system for Note Your installation company will have determined what size battery is required to comply with legislation It is important that your security system is serviced on a regular basis on order that it continues to comply with the legislation Servicing may also be a requirement of you insurance policy In the event of a sustained power cut the system battery will continue to supply the system until the battery voltage falls Fuse Bat eee to a set point at this stage the display will show ES See A fault sounder will start enter a valid User Code to stop the fault sounder At this point it is essential that you contact your installation company Setting the system with Mains Fail In the event of a short term power cut where it is known when power will be restored e g Engineers working on power lines that affect your premises it might be necessary to set this system Please follow the steps outlined below 5 z g Enter Code 1 With the display showing IILI Check I Note In the event of a mains power failure the control panel will display that a fault has occurred if the pre programmed time has been exceeded 2 Enter your User code The display will show Power Out LEADER y p ay 01 JAN 18 58 01 3 Enter your User code again The display will then show Power Cut FAULT Followed by YES if a
20. entral Station and or Vo Comm message communication to inform of system status and alarm events Vo Comm messages may be sent to standard land line telephones or mobile telephones Please take time to familiarise yourself with the type of equipment fitted to your premises as it will prove invaluable whilst using this manual IMPORTANT USER INFORMATION If the Control Panel is non EN then all displays will be shown and ENTER CODE CHECK will not be displayed All information displays will remain until cleared by the User User Code Types Master Level User Code EN2 default 5678 ENS default 005678 Several types of User Codes are available on the Gardtec 595 and each type allows for different levels of access In total 31 User codes may be programmed by a Master Level User Code User number 1 will always be a Master Level User but the remaining 30 User Codes may be programmed to the required level of access You will be advised by your installation company on the code length required The Code Levels should be viewed as four groups Global codes that give system control Area codes that give area control Group codes giving control of more than 1 area and Control codes giving control off outputs The User Code levels available and the functions available for the levels are Global Code Levels affecting full system Set Only Only Allows for the setting of the system Main Allows Setting Part Setting Area Setting Z
21. er area will be unset In the event of the system being set using ACE when the battery is low the display will show ACE Battery Low when the system is unset Press NO to clear the display and then change the battery in the Keyfob Part Setting The System using Master amp Main type codes 1 Note Note Note With the display showing eer eer Enter a Master or Main type code the Do you want to display will show for example Set the System Press 1 2 or 3 for Part 1 2 or 3 the EXIT 1 display will show for example Part 1 15 If a Global code Master or Main has been used all areas that are being set will be Part 1 set If an Area Main code has been used only Part 1 set for that associated area will occur Your installation company will have informed you what zones are being removed omitted for the Part Set you are using Refer to the System Attributes section for what zones have been programmed as Part Set zones Page 6 GardTec 595 4 The exit tone may or may not be heard dependant on the system settings Exit the premises or retire to an unprotected part of the system At the end of the exit time either the exit sounder will stop or a single beep will be emitted dependant on system settings Part Setting System using Area 1 2 or 3 codes 1 With the display showing Enter an Area Code 1 2 or 3 the exit tone will sound a
22. er code will set the full system Note To Set the system with cleaner on site Press CODE YES YES 0 Pre Exit Check At the start of the setting procedure any non exit routes that are open will sound a fault tone The display will show for Zone 008 12hr example n ne All Zones ON If the fault clears within 20 seconds then the exit will begin otherwise the display will return to Day Unset Mode Setting amp Unsetting the System via a Keyswitch One of two types of keyswitch es may have been fitted to your system Normal To set the system with a normal keyswitch insert the key and turn to the ON position then remove the key Follow the instructions from step 3 above To unset insert the key and turn to the OFF position Biased To set the system with a biased keyswitch insert the key and turn it then return the key to the original position and remove Follow the instructions from step 3 above To unset repeat this operation Page 5 User Manual GardTec 595 Unsetting The System 1 Note Note Note Enter the premises via the authorised entry route the broken entry tone will sound proceed to the keypad At the keypad enter a valid code the display will show 01 JAN 18 58 01 The system is now unset If an Area Code has been entered only the area associated with that code will be unset If a Cleaner Code has been entered only the clean
23. ermines if using this user code to Unset the system will trigger the Vo Comm For more details on Vo Comm please refer to the Vo Comm section Press NO until the setting you require is displayed YES or NO Then press Yes The Vo Comm will need to be programmed in order for this option to work please refer to the Vo Comm section in this manual Page 40 Control Code Can Unset ok Or Control Code Can t Unset ok Assigned Area s 123C ok VoComm Trigger On Ok GardTec 595 User Manual 13 If you wish to accept the User Name shown press 7 7 7 ser 02 Name YES and jump to step 18 User 02 Or If you wish to change the User Name shown press U i 3 ser 1 Name NO the display will show a 14 You may now enter up to nine characters for the user name using the layout shown below for the allocation of characters STU VWX YZ 0 9 De i LE ER EC RER ES J 15 Referring to the character map enter the required character pressing the 3 key will display G pressing it again will show H and again will show I once the correct character is displayed press YES and the display will move on to the next position 16 Continue entering characters up to 9 If you require a blank space press YES while the is displayed 17 As you press YES for the ninth character or if you have ju
24. he System with ACE 1 Point the keyfob at the ACE receiver and press the button 2 When the exit tone sounds exit the premises in the usual way Part Setting the System with ACE 1 Point the keyfob at the ACE receiver and press the button 2 When you hear the exit tone press the keyfob button again within 3 seconds for Part Set 1 or Press 1 2 or3 on the receiver keypad for the Part Set you require Unsetting the System with ACE 1 Enter the premises via an authorised entry point 2 Point the keyfob at the receiver and press the button Page 51 User Manual GardTec 595 Programming ACE Keyfobs onto your System Each keyfob will occupy a User number The number of keyfobs that may be used is limited by the maximum number of user codes available on the system up to a maximum of fourteen It is recommended that a keypad entered code is used for the Master User No 1 to allow for the programming of other User functions 1 Follow the procedure for programming user codes to the point when the user code is entered 2 Point the keyfob at the ACE unit and press the button on the fob 3 Repeat this procedure for any other fobs you wish to be programmed using a different user number each time e g User 2 or User 3 etc each time 4 If more than one ACE receiver is fitted fobs need to be programmed onto all ACE receivers retaining the same user number for each individual fob Note When programming the fob onto more than o
25. hen the system has just been Set the display will show for example lt lt SE1 gt gt 01 JAN 18 58 01 For ten seconds 2 The display will then show for example 01 JAN 18 58 01 3 To show the Status of the system Press YES The display will show for example Press CODE Show Status 4 Enter a valid Code to display the Status for a further ten seconds End User Training It is the responsibility of your Installation Company to provide adequate training for people who will be expected to use the system If further training is required for new staff etc please contact your Installation Company This user Manual should be accessible by all people who will be using the system If extra copies are required the manual may be downloaded from our web site www riscogroup com Testing Servicing Your System The system you have installed will give many years of service but it should be tested and serviced on a regular basis by a qualified installation engineer It may be a condition of your insurance policy and or your Police response that it is serviced at regular intervals For details on service periods for your system please contact your installation company Page 49 User Manual GardTec 595 Keypad Alert eo If programmed by your installation company the two PA keys Ara if programmed by the engineer when pressed together will act as alert keys The exact function will depend on what they have been programmed fo
26. ill change as detectors are violated When the premises are secure listen that the exit tone returns to the continuous tone Wait until the exit tone finishes before leaving Note Zone remove is only effective for the one set Page 9 01 JAN 18 58 01 SET the System Do you want to Do you want to REMOVE Zones Enter Zone No then YES or NO then YES or NO Enter Zone No Do you want to SET the System User Manual GardTec 595 Testing The System Master amp Main codes only 1 With the display showing Oi ANNE 20 2 Enter a Master or Main level code Do you want to the display will show SET the System 7 Do you want to 3 Press NO the display will show REMOVE Zones 4 Press NO the display will show eet re seein 9 5 Press YES the display will show TestALL Argas 6 Press YES to test the full system or NO Then select the area you wish to test Then press Yes The display will show 1 Status 4 Strobe for 3 seconds 6 Sounder 9 Bell 7 The display will then show lt All Zones ok gt TESTING 8 Pressing 1 will enter zone Status mode All zones will show on the display and will be deleted as each zone is triggered Press 0
27. in to abort the setting The display will show The system is now reset Page 29 EXIT 1 All Zones ON 15 01 JAN 18 58 01 User Manual Setting the system with Line Fault 1 With the display showing 2 Enter your User code The display will then show Followed by YES if a Master or Main type code has been used 3 Then press YES The display will show Note The display will switch between the EXIT display and the Phone Line FAULT display as the time counts down Page 30 GardTec 595 01 JAN 18 58 01 Phone Line FAULT Can t Set Check EXIT 1 All Zones ON 15 GardTec 595 User Manual Using LED Keypads This section is dedicated to using LED keypads Twin Seven Segment Note Some functions will not be available when using LED RKP s Setting The System 1 2 3 4 5 Note Note With the display showing Enter the User Code followed by YES if Master or Main type code has been used The display will show E and the exit tone will sound Exit the premises via the authorised exit route the exit tone will change if any detectors are violated during exit Once the premises are secure listen that the exit tone returns to the continuous tone Wait until the exit tone finishes before leaving Setting the system with an area code will set only the area associated
28. is Un Programmed VoComm Tel No 3 is Un Programmed VoComm Tel No 4 is Un Programmed Site ID 00 Site ID This Site ID will identify what system is calling you Display will show To change this press NO until the required setting On or Off is displayed then press YES Open Reporting On The term Open relates to the system being Unset With Open Reporting turned On the Vo Comm will report the system being opened Unset for all users who have had the attribute of Vo Comm Trigger On allocated in the User Code Programming Page 19 User Manual GardTec 595 19 The display will show Close Reporting Off The term Close relates to the system being Set With Close Reporting set to anything other then Off the Vo Comm will report the system being closed Set for all users who have had the attribute of Vo Comm Trigger On allocated in the User Code Programming 20 Options available are Off No system Close are reported Full Set Only Full Sets are reported Any Set All Sets Full amp Part are reported Press NO until your required setting is shown Make Sn Alarm then press YES Display will show Test Call 21 Press NO this is dealt with in the using Vo Comm section Do you want to The display will show Set Up VoCom
29. k 7 Press NO until the Code Type you require is displayed Control Then press YES The display will show a Note This screen will not appear if User No 1 is being programmed Group Codes are not available for User No 1 Page 39 User Manual 8 Note 10 11 12 Note Press NO until the Grp you wish to control is displayed For example Grp1 Then Press YES If a Code level other than Control has been chosen the selected Output Group will be activated each time the code is used and the use of the code will be as normal for that level of code If a Code level of Control has been selected the Output Group will be activated each time the code GardTec 595 is entered or G Tag presented and is normally used in conjunction with a Magnetic Lock for limited Door Entry capability and may be given an extra attribute of Can or Can t Unset A Control Level of Code can never Set the system If you have chosen a Control level of code the display will show If you are using another level of code and this screen is not displayed go to step 12 Press NO until the required setting is displayed then Press YES If Can Unset was chosen the display will show If Can t Unset was chosen this screen is not displayed jump to step 12 Use the keys 1 2 3 or O for C Cleaner to toggle the Area s you wish to control with this code When finished press YES Display will show This det
30. ly The Chime zones will have previously been programmed by the installation company A Master level code may change the status of the Chime between On and Off To do so proceed as follows 1 With the display showing 01 JAN 18 58 01 Enter a Master Code the display will Do you want to show for example SET the System Press NO four times the display will show Do you want to Change Chime Page 12 GardTec 595 User Manual 4 Press YES the display will show for example Chime is Off ok DE Chime is On ok 5 Press NO to change the status of the Chime ETTE then press YES the display will show Change Chime 6 Press 0 to escape the display will show 01 JAN 18 58 01 Page 13 User Manual GardTec 595 Programming amp Deleting User Codes Master code only The charts on pages 2 amp 37 should be completed by the engineer user for future reference of what codes have been allocated on your system You will be advised by your installation company on the code length required Under no circumstances should the actual user code be written down If your installation company has given you keyswitches for the operation of your system the last five user codes may have been reserved for use by these keyswitches If your engineer has indicated see pages 2 amp
31. m 22 Press 0 to return to 01 Jan 00 00 01 Page 20 GardTec 595 User Manual Using Vo Comm if fitted Once Vo Comm has been programmed see previous page the Vo Comm will operate in one of two ways 1 Alarms Only The Vo Comm will only communicate when an alarm occurs on a Closed Set system This mode is active when the Open Close option is Off 2 Alarms amp Status The Vo Comm will communicate when an alarm occurs or when the system is Closed or Opened Set or Unset Receiving a Call From Vo Comm When Vo Comm calls you it will start to pass its message as soon as you pick up the telephone At the end of the message you will hear a single tone at this point press a numeric key on your telephone keypad twice A rising tone will be heard that indicates that the call has been acknowledged If you do not acknowledge the call or hear the rising tone the Vo Comm will repeat the message several times and then go on to dial the remaining telephone numbers until the call is acknowledged Messages From Vo Comm Two types of message will be sent by Vo Comm Either a status message or an alarm message Typical Status Message Site 05 Close User 07 This would indicate Site ID 05 was Closed by User 1 The term Closed Set The term Open Unset Note n order for the Vo Comm to report Openings and Closings the Open Reporting for that user must be programmed to On within the Programmi
32. mped from step 13 the display will change to Do you want to Prog USER CODES 18 If you wish to program other User Codes return to step 4 Or Press 0 to return to 01 JAN 18 58 01 Page 41 User Manual GardTec 595 Advanced Setting and Unsetting Using Group Area Codes There are three levels of Group Area Codes Group Master Allows Setting Part Setting Area Setting Zone Remove System Test Viewing the Log Chime On Off Program User Codes Set Time Date Unsetting Will also allow setting unsetting of individual areas for greater system control Group Main Allows Setting Part Setting Area Setting Zone Remove System Test Unsetting Will also allow setting unsetting of individual areas for greater system control Group Area Allows group setting unsetting part setting of a selected group of areas Note Is not able to Set Unset individual Areas Group Area Codes are classed as an Advanced User Function as they allow for greater flexibility on systems that are using multiple areas An example of this may be when a system has Area 1 already Set a user with a Group Area Master or Main Code may enter his her code and change the active areas This removes the need for an Area Level user to remember more than one Area Code or for a Global Master user to unset an entire system in order to set an extra Area In this section we give examples of typical applications for Group Area Code
33. nd the display will show for example Press NO then 1 2 or 3 for the Part Set you require the display will show for example The exit sounders may or may not go silent this will depend on the system settings Exit the premises or retire to an unprotected part of the system At the end of the exit time either the exit sounder will stop or a single beep will be emitted dependant on system settings Quick Part Setting System User Manual 01 JAN 18 58 01 EXIT 1 All Zones ON 15 EXIT 1 Part 1 20 If required there is a quick method to Part Set the system regardless of the level of code being used except Control Level To Part 1 Set the system Enter YES YES CODE The system will now start to Part 1 Set Page 7 User Manual GardTec 595 Area Setting using Master or global Main codes Areas will need to have been set up by the installation company 1 Note With the display showing 01 JAN 18 58 01 Enter a Master or global Main code the Do you want to display will show for example SET the System Press YES to start setting the system the exit tone will sound and the display EXIT 123C will show All Zones ON 30 To turn Area 1 Off press YES 1 and or To turn Area 2 Off press YES 2 and or To turn Area 3 Off press YES 3 and or To turn the Cleaner Area Off press YES 0
34. ne receiver on the same system the button on the fob MUST be held down continuously between programming onto the first and other ACE receivers Note In all cases when the ACE is used only Master amp Main user levels will allow part setting via the keyfob Other code levels will only allow part setting in conjunction with the keypad Page 52 GardTec 595 User Manual User Chart Please use this chart to indicate what user names have been programmed onto your system and those that are in use Page 53 User Manual GardTec 595 Page 54 RISC Creating Security Solutions 9 y With Care RISCO Group UK Ltd Internet www riscogroup co uk Technical Support Tel 0161 655 5600 Technical Support Fax 0161 655 5610 Technical Support e mail technical riscogroup co uk RISCO Group UK Ltd reserve the right to amend the software and features without prior notice INDUSTRY ASSOCIATION A C INVESTOR N PEOPLE PR5526 Rev1 2 5IN595UM C
35. ng User Codes section Typical Alarm Message Site 05 Alarm Zone 06 This would indicate an alarm at Site ID 5 has occurred on Zone 6 Page 21 User Manual GardTec 595 User Initiating Remote Access Optional Access Remote allows your installation company to examine your system and re program system settings as you need the changes without the need for an engineer to visit your premises If your system has remote communications fitted your installation company may have programmed the system so that you initialise the Access Remote call usually on lines with incoming calls barred To initiate the Remote Call follow the instructions below 1 Negotiate with your installation company when you should initiate the Remote Call 2 With the display showing 01 JAN 18 58 01 3 Enter a Master Code the display will show Do you want to SET the System 4 Press NO seven times the display will show Do you want to Access Remote 5 Press YES the display will show Please WAIT Until Dialling commences Then Please WAIT Dialling Until Connection i Please WAIT Then Connect 6 When your installation company has finished the display will show 01 JAN 18 58 01 Note In the event of any errors the display will show I I ERROR Try Again Page 22 GardTec 595 User Manual Re
36. nsetting The System 0 cceesceeseeeeneeeeeeeeneeteeeeeeeeeaas Part Setting The System Quick Part Setting The System REMOVING Zones Setting the system With Mains Fail Setting the System With a Line Fault System Attributes System C Ok 0 re Advanced Code Programming Control Codes Advanced Setting Unsetting Using Group Area Codes Setting Using Group Area Codes Programming Group Area User Codes Setting Using Group Master amp Main Codes Unsetting Using Group Area Codes Unsetting Using Group Master amp Main Codes Adding Areas To a System with Area s Already Set Display Blanking csceeeseeeeeseeeeeseeeeeneeeseneeeeeneeeeee End User Training Testing Servicing Your System Keypad Alert ut tre dote Aone Keypad Tamper pip epar ei System Tampers eeii Ace User Instructions Programming ACE Keyfobs ssssesssnseneeerrnerernerenneeee User Chart E T E LHNOOUUMWU N N _ 11 12 14 17 18 21 21 22 23 26 28 29 30 31 31 31 32 33 33 34 34 37 38 39 42 42 43 46 47 47 48 49 49 49 50 50 50 52 52 53 A 12 13 16 20 25 27 29 41 45 User Manual User Man
37. nt on the system settings Exit the premises or retire to an unprotected part of the system At the end of the exit time either the exit tone will stop or a single beep will be emitted dependant on system settings Part Setting System using Area 1 2 or 3 codes With the display showing Enter an Area code 1 2 or 3 The exit tone will sound and the display will show E Press NO then 1 2 or 3 for Part 1 2 or 3 The bars on the display will change to The two bottom bars if Part 1 has been selected The top and bottom bars if Part 2 has been selected The bottom bar only if Part 3 has been selected The exit tone may or may not be heard dependant on the system settings Exit the premises or retire to an unprotected part of the system At the end of the exit time either the exit tone will stop or a single beep will be emitted dependant on system settings Page 32 GardTec 595 User Manual Quick Part Setting System If required there is a quick method to Part Set the system regardless of the level of code being used except Control Level To Part 1 Set the system Enter YES YES CODE The system will now start to Part 1 Set Area Setting using Master or Global Main codes This function is only available via an LCD RKP Removing Zones Master amp Main codes only If programmed by the installation company individual zones may be removed this may only be done by a Master or Main level of code It shoul
38. one Remove System Test Unsetting Master Allows Setting Part Setting Area Setting Zone Remove System Test Viewing the Log Chime On Off Program User Codes Set Time Date Unsetting Page 3 User Manual GardTec 595 Area Code Levels affecting areas only Area 1 Allows Area 1 Setting Area 1 Part Setting Area 1 Unsetting Cleaner Full System Setting from unset system Cleaner Area Unsetting from set system Cleaner Part Set from part cleaner set system Area 2 Allows Area 2 Setting Area 2 Part Setting Area 2 Unsetting Area 3 Allows Area 3 Setting Area 3 Part Setting Area 3 Unsetting Main 1 Allows Area 1 Setting Area 1 Part Setting Area 1 Zone Remove Area 1 Test Area 1 Unsetting Main 2 Allows Area 2 Setting Area 2 Part Setting Area 2 Zone Remove Area 2 Test Area 2 Unsetting Main 3 Allows Area 3 Setting Area 3 Part Setting Area 3 Zone Remove Area 3 Test Area 3 Unsetting Group Code Levels affecting group or groups of areas Group Master Allows Setting Part Setting Area Setting Zone Remove System Test Viewing the Log Chime On Off Program User Codes Set Time Date Unsetting Will also allow setting unsetting of individual areas for greater system control Group Main Allows Setting Part Setting Area Setting Zone Remove System Test Unsetting Will also allow setting unsetting of individual areas for greater system control Group Area Allows group setting unsetting part setting
39. r But for example if they are pro grammed as panic pressing them will activate the alarm when the system is set or unset Keypad Tamper The keypad will monitor the number keys that are pressed without a valid User Code being entered More than 24 key presses will cause a keypad tamper This will be displayed as Keypad x Tamper and will require a valid User Code entry to stop the sounders If the system was Unset only the internal sounders will operate If the system was Set a full alarm will be generated System Tampers The full security system is tampered any attempt to remove covers from Keypads Control Panel Keypads Bell Box es or detectors will cause a tamper alarm This also applies to cut cables If the system is Unset when the Tamper occurs the alarm will be internal sounders only If the system is Set a full alarm will be generated The alarm may be silenced by entering a valid User Code The system may only be Reset when the Tamper has been cleared otherwise another Tamper alarm will be generated Page 50 GardTec 595 User Manual ACE User Instructions ACE Advanced Control Equipment allows control of your Gardtec 595 system via Infra Red Remote control Ace is available built in to a range of keypads or as a stand alone unit control is via neat remote keyfob s We strongly advise that User Number 1 is not used for ACE in order that the user retains control of the programming functions Setting t
40. s Your installation company will give you further information on the scenarios when Group Area Codes may be used on your system Setting Using Group Area Code Follow the instructions as for normal setting When you are using a Group Area Code only the Area s allocated to that code will be set Page 42 GardTec 595 Programming Group Area User Codes 1 With the display showing 2 Enter a Master Code the display may show 3 Press NO five times the display will show 4 Press YES the display will show 5 Enter the user number 1 to 31 that you wish to program followed by YES the display will show 6 Either enter the User Code you require followed by YES Or Present your G Tag to the Reader The display will show 7 Press NO until the Code Type you require is displayed Grp Mast Then press YES The display will show Note This screen will not appear if User No 1 is being programmed Group Codes are not available for User No 1 8 Use the keys 1 2 3 or 0 for C Cleaner to toggle the Area s you wish to control with this code When finished press YES Display will show 9 Press YES Page 43 User Manual 01 JAN 18 58 01 Do you want to SET the System Do you want to Prog USER CODES Enter User No 1 31 Then YES Now Enter Code Then YES Code Type Master ok
41. sed to ring the Emergency Services directly It will not be possible to program 999 911 or 112 as the telephone numbers that the Vo Comm will dial Before Vo Comm can work several options will need to be programmed Please read below for information Vo Comm Programming if fitted 1 With the display showing 01 Jan 00 00 01 2 Enter a valid Master Level Code Do you want to Display will show SET the System 3 Press NO 7 times Do you want to Display will show Set Up VoComm 4 Press YES VoComm Display will show Off 5 Press NO until display will shows VoComm gt On 6 Press YES me VoComm Tel No 1 Display will show Is Un Programmed Or for example VoComm Tel No 1 12345678910 7 To enter or change this number Press NO TETES Display will show E S EIN Page 18 GardTec 595 8 10 11 12 13 14 15 16 17 18 Enter the telephone number you require followed by YES Display will show To enter or change the number repeat from step 7 Display will show To enter or change the number repeat from step 7 Display will show To enter or change the number repeat from step 7 Display will show Press NO twice Display will show Enter a unique Site ID for the premises 00 to 99 followed by YES User Manual VoComm Tel No 2
42. setting After an Alarm Fault and Alarm Displays Your installation company will have programmed the reset modes for your system so that it complies to your insurance company and legislation requirements Your installation company will have informed you as to the type of reset that your system is set for Before attempting to reset your system ensure that the system is Un set 1 In the event of a fault or an alarm occurring the internal sounder will sound along with the external i Enter Code bells for a full alarm The display will show LLLI Check 1111 if the system is unset If the system is set enter your code to unset it 2 Press the NO key to view the cause of the Alarm or lt lt lt lt ALARM gt gt gt gt Fault Press NO to view Note If NO is NOT pressed then the alarm status will only be displayed for ten seconds 3 The display will then show 11 Enter Code Enter your user code again 1111 Check Do you want to 4 The display will show SET the System ALARM 5 Press 0 The display will show sates NO 6 Press the NO key to view the cause of the alarm or Zone 005 TAMPER fault The display will show for example 01 JAN 18 58 01 7 If more than 1 event is present the display will Zone 005 TAMPER show 01 JAN 18 58 01 gt The right arrow is now indicating that more events
43. stem will start to Set the selected Areas 5 Leave the premises via an authorised exit route Page 46 GardTec 595 Unsetting Using Group Area Code User Manual Follow the instructions as for normal Unsetting When you are using a Group Area Code only the Area s allocated to that code will be Unset Unsetting Using Group Master amp Group Main Codes 1 With the display showing Areas 1 amp 3 are already Sei Enter a Group Master or Group Main level Code Display will show Press NO Display will show for example If you wish to Unset all the Areas Press YES The system will Unset all Areas Or If you wish to Unset just 1 of the Set Areas Press NO Display will show for example Areas 1 amp 3 are Set Press the key corresponding to the Area you wish to Unset in this example press 3 The display will show Press Yes when you are happy with your selection Display will now show Area 3 has now been Unset After 10 seconds the display will show Page 47 01 JAN 18 58 01 lt lt SET1 3 gt gt Set Area s Unset ALL Areas Set 1 3 Off Ok Set 1 Off 3 Ok lt lt SETI gt gt 01 JAN 18 58 01 01 JAN 18 58 01 User Manual GardTec 595 Adding Areas to a System with Area s Already Set Group Master amp Group Main Codes If your system already
44. ual GardTec 595 User Information System Information Keypad 1 Location Keypad 2 Location Keypad 4 Location Keypad 5 Location Keypad 6 Location Keypad 7 Location Keypad 8 Location Z e Q A O O w Q n alaala Keyswitch 1 Location Reserved User Code User No Keyswitch 2 Location Reserved User Code User No Keyswitch 3 Location Reserved User Code User No Keyswitch 4 Location Reserved User Code User No Keyswitch 5 Location Reserved User Code User No Keyswitch 6 Location Reserved User Code User No Keyswitch 7 Location Reserved User Code User No Keyswitch 8 Location Reserved User Code User No External Proximity Reader 1 Location External Proximity Reader 2 Location Internal Proximity Reader 1 Location Internal Proximity Reader 2 Location Installation Company Name Installation Company Tel E mail Web Address Other Information Note THIS SECTION MUST BE COMPLETED BY THE INSTALLATION ENGINEER Page 2 GardTec 595 User Manual Introduction The GardTec 595 Control Panel is capable of controlling up to 40 zones with 30 individual Users Control of the system is via Remote Keypads RKPs and two types of display variation are available LCD giving two rows of 16 character English text and LED giving two 7 segment LED digits Control is also possible via Proximity Reader s Some of the more advanced option of the system are only available through the LCD RKP s Facility is provided model dependant for C
45. ween the EXIT display and the Power Cut FAULT display as the time counts down Setting the system with a Line Fault 1 2 With the display showing Enter your User code The display will then show PL Followed by YES if a Master or Main type code has been used Then press YES Note The display will switch between the EXIT display and the Phone Line FAULT display as the time counts down Page 34 GardTec 595 User Manual Testing The System Master amp Main codes only This function is only available via an LCD RKP Viewing The Event Log Master code only This function is only available via an LCD RKP Changing The Chime Status Master code only This function is only available via an LCD RKP Programming User Codes Master code only This function is only available via an LCD RKP Programming Date amp Time This function is only available via an LCD RKP User Initiating Remote Access This function is only available via an LCD RKP Resetting After An Alarm This function is only available via an LCD RKP Page 35 User Manual GardTec 595 Vo Comm if fitted This function is only available via an LCD RKP Setting Engineer Authorisation This function is only available via an LCD RKP Re setting the display after a Mains Fail This function is only available via an LCD RKP Page 36 GardTec 595 User Manual System Attributes one Type Descriptor Areas 1 2 3 Part

Download Pdf Manuals

image

Related Search

Related Contents

Istruzione d`uso  Orbis Op Man inside (English)  Ewent EW1241 cable lock  Téléchargez la fiche technique au format PDF  N8180-41A マルチサーバ接続 BOX 取扱説明書    USER MANUAL FE1&10/100BASE  Bedienungsanleitung Click & Go Compact  Mode d`emploi testo 206 Appareil de mesure de pH/de température  Philips SWV2006W User's Manual  

Copyright © All rights reserved.
Failed to retrieve file