1. CONNECTION TO ELECTRONIC CARD H C H L Ve En Power supply wires 110 120V 50 60Hz H C Black heating element wire H L White heating element wire H H Red heating element wire M Motor wire 4 110 120V 50 60Hz H H Power supply wires CONNECTION TO ELECTRONIC CARD H C Black heating element wire M H L White heating element wire yy gt M Motor wire Connection wires is E R sensor circuit Connection wires to IR sensor circuit BREAKDOWN LIST OF BASIC PARTS MO2 UL amp MO3 UL MO2 UL MO3 UL White painted steel cover 1 RC82010 Satin finish stainless steel cover 1 RC82020 Bright finish stainless steel cover 1 RC82030 Motor 2 RC82748UL Fan wheel 3 RC82777 Heating element 4 RC82770UL RC82720UL Electronic circuit set 5 RC82600UL RC82610UL IR sensor circuit 6 RC82601UL Main electronic card RC82602UL 8 Coal brushes set RC95750 AMT RC95750 STC www saniflowcorp com medicinics METHOD OF USE j M02A UL and M03A UL families of hand dryers operate by hand detection To achieve optimum drying of 8 2 hands it is advisable to rinse them well first eliminating any soap left o
2. USA SANIFLOW CORPORATION 2655 LeJeune Rd Suite 810 Coral Gables FL 33134 Tel 305 424 24 33 Fax 305 424 24 35 info saniflowcorp com www saniflowcorp com SPAIN MEDICLINICS S A Industria 54 E 08025BARCELONA Tel 34 93 446 47 00 Fax 34 93 348 10 39 info mediclinics com www mediclinics com 04 04 Cod 82917UL medicinics www saniflowcorp com HAND DRYERS M02A UL MO2AC UL M02ACS UL M03A UL MO3AC UL MO3ACS UL INSTALLATION AND OPERATING MANUAL www saniflowcorp com medicinics medicinics INSTALLATION Dismantling for installation The hand dryer is supplied with the metallic cover coupled to the base in a unscrewed stated The cover should be extracted taking into account its upper rib placed in its fitting on the base The cover must be removed obliquely until the upper rib has been extracted Take care to avoid Damaging the internal parts mainly electronic components Damaging the cover It is recommended placing it on a flat surface facing upwards and on a cloth Mounting The assembly should be preferably prepared for rear ducting Drill holes of 5 16 8 mm in the wall using the template supplied Clean the holes of the resulting dust and insert the plugs Pass the power cables from the wall through the 7 8 22 mm hole situated beneath the connection board of the appliance Screw the base of the appliance tightly to the wall ensuring th
3. but not limited to any defects or damage caused by or resulting from a alterations to the product b use of the product in an incorrect manner or for an unreasonable use c failure to use the product in a safe and reasonable manner and d repair of the product by unauthorized personnel LIMITATION ON LIABILITY THE WARRANTY SET FORTH ABOVE IS EXCLUSIVE AND NO OTHER WARRANTY WHETHER WRITTEN OR ORAL IS EXPRESSED OR IM PLIED MEDICLINICS S A SPECIFICALLY DISCLAIM S THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT SHALL MEDICLINICS S A BE LIABLE FOR INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAM AGES INCLUDING BUT NOT LIMITED TO LOSS OF PROFITS LOSS OF CUSTOM ERS LOSS OF USE DAMAGE TO GOODWILL OR TO BUSINESS REPUTATION OR FOR ANY OTHER LOSSES FROM ANY CAUSE INCLUDING DAMAGES CAUSED BY THE PRODUCT WHETHER OR NOT MEDICLINICS S A HAS RECEIVED NOTICE OF THE POSSIBILITY OR CERTAINTY OF SUCH DAMAGES OR LOSSES SOME STATES DO NOT ALLOW THE EXCLUSION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE ELECTRIC DIAGRAM MO2A UL MO2AC UL and MO2ACS UL models M Motor S Sensor H Heating element ELECTRIC DIAGRAM MO3A UL MO3AC UL and MO3ACS UL models M M Motor H S Sensor H Heating element
4. dures of the machine must be carried out by qualified technical staff
5. e 4 silent blocks are correctly positioned Enter the power cables and earth wire into the inside space containing the terminal strip passing them through the entry hole To reach the terminal strip the protective top should be opened Connect the cables from the mains and earth wire to their locations in the terminal strip Once the electrical connection has been made close the protective cover again Fit the metallic cover into the base placing it from top to bottom with a certain inclinations Make sure the upper rib has entered in their location in the base Place the lower screws tightening with the specially supplied key Upper ribe Location in the base medicinics www saniflowcorp com WIRING DIAGRAM www saniflowcorp com LIMITED WARRANTY This Product covered by this limited warranty is warranted to be free from defects in material and workmanship under normal conditions for a period of ten yearsfrom the date of purchase The manufacturer s obligation under this Limited Warranty isapplicable only where a product defect has been claimed during the warranty period The manufacturer s obligation under this Limited Warranty is limited to either I replacement of the Product or II replacement of defective parts To claim under this Limited Warranty contact one of Mediclinics S A official dealers Medidinics SA shall not be responsible for any other damage induding
6. n them Then once the dryer is working place the hands at the distance of approximately 2 3 8 2 3 4 6 7 cm from the air outlet and rub the hands E toguether The detection of hands is based on the emission reception of an IR light beam F SES 8 2 SNF Eg MO2A UL MO2AC UL MO2ACS UL models E 5 5 858 5 The detection distance is approximately 4 3 4 5 7 8 12 15 cm but other levels 3 E E may be set by adjusting the potentiometer wich is located in the IR sensors circuit B 5 After removing the hands the appliance stops 2 3 seconds The heating element turns off 0 5 seconds before the motor g The appliance includes a protection system against continuous improper use m EN m 3 it stops after 120 seconds of continuous use E 2 EE _ 5 These models of hand dryer has an automatic temperature control system It supplies 9 amp E the adequate heating power from 4 possible levels according to the value of room 5 a io _ temperature E m zs 8 E These models detect the presence of fixed objects as fixed targets and in this case M E ee zi it stops automatically after 4 5 seconds of starting operation a UIE Models x Q 2 E e PREVENTATIVE MAINTENANCE AND CLEANING amp E pm E Correct cleaning of the machine will lenghten its working life considerably 2 E E 8 It is
7. recommended to carry out the cleaning process at least once a year 5 9 amp 8 CLEANING METHOD amp 2 2 Ed ew Disconnect the dryer from the mains supply 3 f 5 Remove the 2 lower holding screws from the cover using the special key s 2 E 5 Remove the cover and place it carefully on a cloth avoiding scratches and scrapes E Clean the dust from the surface and the parts of the main card of the electronic circuit To do this use a soft brush SIS E Use the same brush to clean the motor surface the entrance inlet of the volute the air outlet and the air inlet grille 2 EE S With a soft cloth clean the surface of the IR sensor closure screen and remove any dust covering on its surface 3 amp S E Open the volute removing the safety screw and folding the closure clips and clean the turbine and heating element of 5 e E 2 5 dust Close the volute again putting in the closure clips and tightening the safety screw ui Clean the dust from the perimeter of the base especially the upper section Assemble the cover place the lower screws and connect the dryer once again Start up the machine repeatedly in order to expel remains of dust after the cleaning process gt 5 E 5 z T 8 g m 53 55 a 25 amp Sud EB Do not damage or force any part during the entire process 9 9385 5 28 28888282 P 38 EEE All cleaning proce