Home

Department of Biochemistry

image

Contents

1. C 20 72 C 0 4 C 90 C Control Accuracy 0 2 C Heating rate 3 C s or higher Cooling rate 2 C s or higher Intuitive graphic programming Booking schedule allows users to reserve the instrument in advance Customized programming allows a maximum of 20 steps and 99 cycles Runtime display shows remaining time in larger font for better view from distance System memory of more than 100 User folders and more than 700 programs 10 000 protocols USB ports for Protocol transfer Self test USB printer mouse Log book function for error messages and new calibration Machine should sent E mail Notification to the specified Email id about the instrument status Power save Standby function Option to connect up to TWO PCR machine for ultimate throughput Optional Self test dongle to check functionality of all 6 peltier elements Optional in situ adapter for running 4 slides 27 28 29 30 31 32 33 34 35 10 11 12 Ability to store methods on external card for safety and multiple user capability Adjustable ramp rate from 0 1 C to 3 0 C to meet critical amplification conditions Calibration according to NIST DKD UKAS standards Pre loaded protocols must be available Graphical LCD display must be available System must meet directives of Restriction of Hazardous Substances RoHS compliant with indication of 2011 65 EC directive in certificate CE amp ISO certified Validation and calibration fa
2. urgently Tenders should please state the guarantee delivery period they can offer As delivery date is essence of the contract this should be strictly adhered to by the successful tenders 7 No supply which is not according to the specifications and not meeting our requirement will be accepted 8 The Director shall have the right of rejecting the Limited Tender in whole or part without assigning any reason therefore 9 Incase of high precision instruments the firms should give a guarantee certificate for their satisfactory performance 10 The firms participating in the limited tender must have registered their firms with purchase section of JIPMER before their quotations 11 Limited tender quotations should be sent only by Certificate of Posting Registered Post Speed Post Reputed Courier Service 12 The quotation should be addressed to The Director JIPMER Puducherry 6 and postal address should be The Head of the Department Department of Biochemistry Second Floor Academic Block JIPMER Puducherry 605006 Please furnish you limited tender in a sealed cover subscribing as Limited tender for Gradient PCR Tender No JIP BIOCHEM ERRC LT 1 2014 15 Dated 13 08 2014 Head of the Department Department of Biochemistry JIPMER Puducherry 6 Due Date 28 08 2014 Time Upto 1 00 PM Limited tender should reach this office on or before 28 08 2014 by 1 00 pm Limited Tender received after the due date will be summarily rejected
3. JAWAHARLAL INSTITUTE OF POST GRADUATE MEDICAL EDUCATION amp RESEARCH Institution of National Importance Under Ministry of Health amp Family Welfare Government of India Dhanvantari Nagar Puducherry 605 006 Department of Biochemistry Tender No JIP BIOCHEM ERRC LT 1 2014 15 Dated 13 08 2014 To Dear Sir Madam Sub Supply of Gradient PCR Limited Tender Invited Reg Please quote your lowest rates for supply of the GRADIENT PCR as per the list given overleaf attached subject to the following terms and conditions 1 Registered firms with JIPMER only can quote for the above OR the firms should register in JIPMER before submitting quotation Please contact 0413 2296016 for Vendor Registration Purchase Section 2 Rates should be quoted only for the items which are available in stock and can be supplied immediately on receipt of order W Rate should be quoted inclusive of all Government Taxes 4 No insurance charges are payable as per the rules in the Government As such the firms before quoting may take into consideration all the risks in the transit and then furnish Limited Tender which should cover insurance charges also If any point is raised as regards insurance charges after orders are issued the same will not be entertained and the firms thereafter should effect the supply at their own cost 5 Rates should be quoted F O R Puducherry Extra packing forwarding charges etc should not be quoted 6 Delivery is required
4. Yours faithfully Copy to Purchase Section for information For DIRECTOR JAWAHARLAL INSTITUTE OF POST GRADUATE MEDICAL EDUCATION amp RESEARCH p lt O OWN AU A U N 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Institution of National Importance Under Ministry of Health amp Family Welfare Government of India Dhanvantari Nagar Puducherry 605 006 Department of Biochemistry Operational Requirement Compatible universal and user friendly suitable for both short time operation and continuous operations Technical Specification for Gradient PCR Interchangable or Multiple Thermal Block capacity in a single unit with following block should be quoted e 96 X 0 1 ml PCR Strips e 96 X 0 2ml PCR tube e 71 X 0 5ml PCR Tube e 1X 96 Well PCR Plate Heating Lid to avoid evaporation of samples Temperature control of block 4 99 C Temperature control mode Fast standard and safe all in Gradient mode Block should maintain 20 C until the set lid temperature reaches Gradient Block Over 12 Columns and gradient possible in all three steps Gradient selectable from 1 20 C across the entire temp control range Gradient should be capable of running at the specified ramping rates Heating amp cooling ramp rates should be identical both in gradient and normal operations 10 Possibility to set time and temperature increments in PCR programming Block Homogeneity 0 3
5. cility should be available in the system Auto restart option in event of Power failures Should be supplied with all standard Accessories amp Consumables for 200 reactions General Terms amp Conditions Equipment must be quoted in Indian Currency Only Taxes if any should be mentioned separately and clearly The equipment and all accessories should be under warranty for a period of THREE YEARS after successful commissioning The necessary required Consumables should be quoted separately and the rate of the same should be frozen for next 5 years Consumables rates will also be considered during price comparison All essential spare parts and service manuals should be available with the local services during warranty period AMC rates for a period of 5 years after the warranty period should be quoted separately and this would be taken into consideration in comparing the price bids AMC should include 4 preventive maintenance and any number of breakdown calls A copy of service manual should be available with local service centre The after sales service should be available preferably within 24 hours and with trained service personnel from Chennai or nearer locations Should be quoted with suitable online UPS with 30mins battery backup for equipment The equipment and all accessories should be installed tested commissioned and trained at the Department of Biochemistry JIPMER Puducherry free of cost All spare parts and consumables should be availabl
6. e with the supplier or principals for a period of 10 years A user list of the quoted equipment from reputed government institutes must be provided The supplier has to impart on site training at the time of installation To be filled by the firm in their Letter Head Declaration 1 Iam Registered Firm of JIPMER and My Registration No 2 All the Specification of the Equipment I quoted meets the specification of JIPMER requirement YES NO If No any Deviation Pls mention the S1 No and comment in the Below line 3 I accept all the General Terms and Conditions in the Tender Signature Name Designation Company Seal

Download Pdf Manuals

image

Related Search

Related Contents

CAMEO Manual - Hazmat Oklahoma  Snapper 1726794 Lawn Mower User Manual  Medisana Bloodpressure monitor MTP Plus  indicador numérico analógico manual do usuário  備品・消耗品  Honeywell Dehumidifier DR90 User's Manual  MANUAL_ATS. Tamaño :  Istruzioni per l`uso  Using Your Adapt9S12XDP Microcontroller Module  GrandTec CCD-2000 User's Manual  

Copyright © All rights reserved.
Failed to retrieve file