USER MANUAL For Surgical Lamp REFTECH Series Mobile Type

image

Contents

1. Shaowless reate with single baffle in deep cavity 220 Shaowless reate with double baffles in deep cavity 230 B v1 0 File No BW QS04 02 Shadowless effective of Shadowless rate with single baffle 210 Shadowless rate with double baffles 230 Shadowless rate in deep cavity of the body 290 50cm domes Shaowless reate with single baffle in deep cavity 210 Shaowless reate with double baffles in deep cavity 230 Ra Ra 294 Color Temp 4300K 250K Total pa Ee lt 1000W m Ee Ec lt 6mW m Irradiance Recourse 150W 24V re 200VA Consumption Net Weight 88Kg 51Kg Safety Level I Sterilization Follow the manual Fuse RT1 30 T4AL 250V in network
2. Date May 2009 USER MANUAL For Surgical Lamp REFTECH Series Mobile Type Bowin Medical Co Ltd R 2105 No 1619 Dalian Road Shanghai 200086 China Tel 8621 65038590 Fax 8621 65038586 www bowin med com File No BW QS04 02 Caution The surgical lamp has strictly requirement during the installation please check the relative clause of the manual carefully 1 Don t scratch and knock the glass of the lampshade 2 Please shutdown the power and wait until the bulb being cool to avoid the accident of scald when you change the bulbs 3 As the inner temperature of some parts of the domes will above 75 C the lamp choose Fluorine plastic high temperature wire which shall resist the temperature above 200 C 4 Please note if the endothermic glass of the domes broken uninstall or two domes irradiation into the same area the temperature rise is possible to exceed the standard The user should take care about this 5 Please usually check the fastener of the suspension system of the surgical lamp to prevent any kind of accident happen 6 For the security reason please do not dismantling or modify the surgical lamp without the permission of our manufacturer 7 The usual life of the surgical lamp is ten years please do not exceed such recommendation Symbols Explaination O ON OFF amp MAIN BULB BROKEN i a LUMINATION ADJUSTMENT UP BACK UP BULB BROKEN L V LUMINATION ADJUSTMENT DOWN OoOO O O O O O LUM
3. INATION INDICATION BAR The surgical lamp REFTECH Series is shadowless which meet the request of illumination by most hospitals clinics The domes part is for illumination the balance arm is for hang the domes and control the B v1 0 File No BW QS04 02 balance of movement and location of the domes And the electrical control part is for control the luminance of the light bulb replacement and bulb broken alarming Model REFTECH6000M Mobile type with 60cm centimeter domes REFTECHS5000M Mobile type with 50cm centimeter domes Installation See the diagram 1 Fix the brake on the balance lock of the base and take the wire through the inferior column Fix the inferior column with 4 sets of screws and put on the decorative cover fix with anchors are prohibited See diagram 1 2 Set the decorative gasket on the inferior column Peel the wire 10mm each in red blue green which are on the lateral of the column Link the same color on with connection cap and fix with 2 sets of screws See diagram 2 3 Put the decorative gasket on the bottom of balance arm Lift it up balanced and interlink the top of the top column then fix with 2 sets of screws See diagram 3 Insert the bend of the domes into the balance arm and fix the screws See diagram 4 5 Set and adjust the power line well See diagram 6 a oe gt NS Balance Arm Under Column a 6 1 The Base Pa Power Socket Operation Lamp Mobile Type N
4. e item of the fuse indicate on the label 5 Once the OT Lamp can not be located please repeat the Installation No 6 6 Recommendation Clean the OT Lamp with wet fabric out of liquid then sterilized with Formaldehyde or ozone fumigation agent and irradiate with UV Put the focusing handle into Glutaraldehyde or 134 C steam to sterilize it for 20 miniutes Prevent the handle from extrusion during the sterilization Please follow the instruction of medical instruments sterilization of your regional requirement After Sale Service 1 REFTECH Series OT Lamp can be used for 10 years and the warranty will be 18 months after the B L date The following situations are out of our warranty include Improper Use Illegal Modification Damage cased by dismantling 2 Disposables such as bulb fuse focusing handle are all out of the range of warranty 3 We offer forever service and technical consults we will offer the service manual if necessary Maintains The user should check the OT Lamp each three months for the follow Fastener Back up Bulb If the domes can be located balanced If any problem exist please check the manual and if the problems still unsolved please contact us Environmental protection Erase the OT Lamp at the end of its life please accord to the treatment of general lighting Fault analysis and solution B v1 0 File No BW QS04 02 Phenomanon Analysis Solution The indication on the 1 Plug off 1 Pl
5. ote External power line should meet the request of IEC60245 1 with either ordinary wear rubber sheathed flexible cable or ordinary PVC sheathed flexible cord the diameter will be 1 0 mm B v1 0 File No BW QS04 02 6 Choose the relative Allen Wrench to adjust the screws of the brake and the balance arm until the balance arm with the domes can be located in any points of the area and feel flexible Operation i 1 Connect the plug and the indication light on the control panel on Click D to switch on the lamp click the button to adjust the luminance After the operation click D again to switch off the lamp then power off the master switch 2 Rotate the focusing handle for focusing and position adjustment the handle can be put off for sterilization The focusing handle is for operators only other is prohibited for touch the handle for the consideration of purification Click the button on the beneath of the focusing handle to put it off 3 Once the light on the control panel shining please change the bulb after the surgery for the preparation of the next one Please remember switch off the main power and ensure the bulb become cool before change the bulbs Please read the instruction manual on the box of the bulb how to handle to bulb Bulb model OSRAM HLX64640 24V 150W 4 When the fuse broken please switch of the main power and shut down the base together with the electrical box first please choose the relativ
6. ug on control panels useless 2 Fuse burned 2 Change the Fuse Lamp doesn t work Indication on the 1 Both bulbs burned 2 Bad Electrical 3 Panel Fault 1 replace blubs 2 Check the 24V output to the bulb with multimeter panel flick 3 replace the control panel 1 Bad brush or wire point 1 Check the 24V output to the OT Lamp flick f 2 High frequency equipments in the bulb with multimeter disordered same network such as ESU 2 Erase the effective equipments Arm and domes can t be located well 1 Loose screws of the brake 2 Fatigue spring of the arm l adjust the screws 2 adjust the spring Normal environment for USE Power 220V 50Hz 110V 60Hz Temperture 10 30 C Humidity lt 75 Atmospheric Pressure 700 1060hpa The Lamp can t be used in the environment of follow 1 The combination of Combustible Anesthesia and Air 2 The combination of Oxygen and Nitrous Oxide Transportation and storage condition Temperture 40 55 C Relative Humidity lt 93 Atmospheric Pressure 500 1060hpa Main Specification Model REFTECH6000M REFTECHS5000M soe on 130000Lx lt Ec lt 160000Lx 80000Lx lt Ec lt 140000Lx a aan dio 130mm dso 70mm Focusing 800mm Depth Shadowless rate with single baffle 225 Shadowless_ Shadowless rate with double baffles 230 effective of Shadowless rate in deep cavity of the body 290 60cm domes