Home

System Board D2440/D2932 for RX330 S1

image

Contents

1. GOO Burr s Figure 4 Schematic overview of the system boards D2440 D2932 1 J10 power supply CPU 2 2 J25 power supply Ic 3 J21 power supply ATX 4 J17 power supply CPU 1 5 J22 safety switch 6 J15 IDTEMP 7 J40 fan 1 3 Sys 8 IDE primary 9 SAS6 10 SAS5 112 SAS4 12 SAS3 13 SAS2 14 SAS1 15 SATA1 16 J51 left backplane 17 J49 right backplane 18 J8 USB front panel 19 2 J48 LED front panel 20 battery 21 DIP switches D2440 D2932 RX330 S1 Technical Manual 21 Connectors and DIP switches Features Settings with DIP switches The system board is supplied with all switches set on default position OFF Switch 1 CMOS OFF CMOS RTC settings are not cleared default ON CMOS RTC settings are cleared Switch 2 BIOS Write OFF The System BIOS can be written or deleted Flash Protect BIOS update from floppy disk is possible default ON The System BIOS can neither be written to nor deleted Flash BIOS update from floppy disk is not possible Switch 3 Password Skip OFF The password query is effective default ON The password query is skipped Passwords are deleted Switch 4 Recovery OFF The System BIOS is started with the system BIOS from the system board default ON The system boots from the Flash BIOS floppy disk and reprograms the
2. Li indicates additional information notes and tips Table 1 Notational conventions D2440 D2932 RX330 S1 Technical Manual 2 Important notes In this chapter you will find essential information regarding safety when working with your server CAUTION With the system board installed you must open the system to access the system board How to access the system board of your system is described in the appropriate service supplement When handling the system board refer to the specific notes on safety in the operating manual and or service supplement for the respective server 2 1 Notes on safety CAUTION e The actions described in these instructions should only be performed by authorized qualified personnel Equipment repairs should only be performed by qualified staff Any failure to observe the guidelines in this manual and any unauthorized openings and improper repairs could expose the user to risks electric shock fire hazards and could also damage the equipment Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability e Transport the device only in the antistatic original packaging or in packaging that protects it from knocks and jolts e Only install expansions that are allowed for the system board If you install other expansions you may damage the requirements and rules governing safety and electromagnet
3. http ts fujitsu com recycling For details on returning and reuse of devices and consumables within Europe refer to the Returning used devices manual or contact your Fujitsu Technology Solutions branch office subsidiary or our recycling centre in Paderborn Fujitsu Technology Solutions Recycling Center D 33106 Paderborn Tel 49 5251 8 18010 Fax 49 5251 8 18015 12 Technical Manual D2440 D2932 RX330 S1 3 Features For the PRIMERGY RX330 S1 server the system boards D2440 and D2932 are available The system boards differ in Firmware processors and main memory 3 1 Overview Processors D2440 D2932 2 x AMD649 Opteron Dual Core or Quad Core Barcelona processors 2 processor sockets F 1207 integrated Memory Controller AMD PowerNow Technology with Optimized Power Management OPM 2 x Opteron Quad Core Shanghai processors 2 processor sockets F 1207 integrated Memory Controller AMD PowerNow Technology with Optimized Power Management OPM Main memory D2440 D2932 8 slots for main memory ECC DDR2 533 PC4300 or ECC DDR2 667 PC5300 SDRAM memory modules with 512 MB 1Gbyte 2 Gbyte and 4Gbyte maximum 32 Gbyte of memory ECC multiple bit error detection 8 slots for main memory ECC DDR2 800 PC6400 SDRAM memory modules with 1 Gbyte 2 Gbyte and 4Gbyte maximum 32 Gbyte of memory ECC multiple bit error detection Chip s
4. LAN connectors Dual Gbit LAN controller 1 LAN link activity green on LAN connection off no LAN connection flashing LAN transfer 2 LAN transfer rate green 4 off transfer rate 10 Mbit s or yellow no connection green on transfer rate 100 Mbit s yellow on transfer rate 1000 Mbit s 1 2 Figure 7 LAN connector Service LAN controller 1 LAN link activity green on LAN connection off no LAN connection flashing LAN transfer 2 LAN transfer rate green off transfer rate 10 Mbit s or no connection on transfer rate 100 Mbit s 24 Technical Manual D2440 D2932 RX330 S1 4 Replacing the lithium battery In order to save the system information permanently a lithium battery is installed to provide the CMOS memory with a current When the charge is too low or the battery is empty a corresponding error message is provided The lithium battery must then be replaced CAUTION The lithium battery must be replaced with an identical battery or a battery type recommended by the manufacturer CR2032 Do not throw lithium batteries into the trash can It must be disposed of in accordance with local regulations concerning special waste Make sure that you insert the battery the right way round The plus pole must be on the top ma zal Figure 8 Replacing the lithium battery gt Press the locking spring into direct
5. electromagnetic compatibility EPROM Erasable Programmable Read Only Memory 28 Technical Manual D2440 D2932 RX330 S1 Abbreviations ESD ElectroStatic Discharge elektrostatische Entladung EVRD Enterprise VRD HPC Hot plug Controller FPC Front Panel Controller FRU Field Replaceable Unit FSB Front Side Bus ICE In Circuit Emulation IDE Integrated intelligent Drive Electronics IEC International Electrotechnical Commission IME Integrated Mirroring Enhanced IOOP Intelligent Organisation Of PCI IPMB Intelligent Plattorm Management Bus IPMI Intelligent Plattorm Management Interface iRMC integrated Remote Management Controller D2440 D2932 RX330 S1 Technical Manual 29 Abbreviations ISO International Organisation for Standardisation LAN Local Area Network LED Light Emitting Diode MPS Multi Processor Specification NMI Non Maskable Interrupt OEM Original Equipment Manufacturer OHCI Open Host Controller Interface OS Operating System PCI Peripheral Components Interconnect PDA Prefailure Detection and Analyzing PIO Programmed Input Output PDB Power Distribution Board PLD Programmable Logic Device PS U Power Supply Unit 30 Technical Manual D2440 D2932 RX330 S1 Abbreviations PWM Pulse Wide Modulation PXE Preboot eXecution Environment RAID Redundant Array of Inexpensive Disks RoHS Restriction of the Use of Certain Hazardous Subst
6. ensure that extension boards are slotted in straight without damaging components or conductors on the system board or any other components for example EMI spring contacts Be careful with the locking mechanisms catches centring pins etc when you replace the system board or components on it for example memory modules or processors Never use sharp objects screwdrivers for leverage 2 2 CE certificate of the EEC directive 89 336 EEC Electromagnetic compatibility C The shipped version of this board complies with the requirements Compliance was tested in a typical PRIMERGY configuration 10 Technical Manual D2440 D2932 RX330 S1 Important notes Environmental protection 2 3 Environmental protection Environmentally friendly product design and development This product has been designed in accordance with standards for environmen tally friendly product design and development This means that the designers have taken into account important criteria such as durability selection of materials and coding emissions packaging the ease with which the product can be dismantled and the extent to which it can be recycled This saves resources and thus reduces the harm done to the environment Notes on saving energy Devices that do not have to be on permanently should not be switched on until they need to be used and should be switched off during long breaks and on completion of work Notes on packaging Ple
7. system BIOS on the system board 22 Technical Manual D2440 D2932 RX330 S1 Features Connectors and DIP switches 3 6 1 External connectors Figure 5 External connectors of the system boards D2440 D2932 1 PS 2 mouse port 6 LAN port 1 2 Serial port COM2 7 USB port 3 USB port 2 8 VGA port 4 LAN port M Service LAN 9 Serial port COM1 5 LAN port 2 10 PS 2 keyboard port LAN connectors On this system board you will find a Broadcom 5715 Dual Gbit LAN controller and a Service LAN controller The Dual Gbit LAN controller supports the transfer rates of 10 Mbit s 100 Mbit s and 1 Gbit s and supports WOL function through Magic Packet It is also possible to boot a device without its own boot hard disk via LAN Here PXE and iSCSI protocol is supported The LAN controller connectors are equipped with two LEDs light emitting diode indicating the transfer rate and the activity It is possible to define the LAN port 2 as the Service LAN port and Standard LAN port via BIOS setting In this case the LAN port M will be deactivated The LAN port 2 takes over the Service LAN functionality and the standard LAN port in common virtual LAN requires two different IP addresses D2440 D2932 RX330 S1 Technical Manual 23 Connectors and DIP switches Features Figure 6
8. Connectors and DIP switches 3 6 1 External connectors 2 229249 en aaa S x REX S 4 Replacing the lithium battery Abbreviations a ss sa ss weed a anna D2440 D2932 RX330 S1 Technical Manual 1 Introduction This technical manual describes the system boards D2440 D2932 which can be equipped with one or two AMD processors Further information about drivers is provided in the readme files on the hard disk on the supplied CDs or DVDs You will find further information in the BIOS description Notational conventions The meanings of the symbols and fonts used in this manual are as follows italics indicates commands menu items file and path names or software programs fixed font indicate system output on the monitor semi bold fixed font indicates values to be entered through the keyboard Key symbol indicates keys according to their representation on the keyboard If capital letters are to be entered explicitly then the Shift key is shown e g SHIFT A for A If two keys need to be pressed at the same time then this is shown by placing a hyphen between the two key symbols quotation marks indicates names and terms that are being empha sized indicates an operation that to be performed CAUTION indicates warnings which if ignored will endanger your health destroy the system or lead to the loss of data
9. DDR2 667 PC5300 D2932 ECC DDR2 800 PC6400 ECC with memory scrubbing is supported You will find the descriptions how to install memory modules in the Options Guide of your server Module population ao DIMM1B co a4 DIMM1A co CPU 2 ci DIMM2B co umm DIMM2A co co DIMM4A co DIMM4B a DIMM3A um DIMM3B CPU 1 Figure 2 Main memory Ifthe memory modules are populated in pairs each pair must consist of identical memory modules 2 way interleaved mode The module capacity between pairs can differ pair 2A 2B can be populated with two 1 GMbyte modules and pair 1A 1B with two 2 Gbyte modules CPU 2 must be installed to access DIMM3A 3B and DIMM4A 4B D2440 D2932 RX330 S1 Technical Manual 15 PCI bus Features Following table shows the mandatory population order DIMM DIMM DIMM DIMM 2A 2B 1A 1B 2 empty empty popu popu DIMMs lated lated 4 popu popu popu popu DIMMs lated lated lated lated CPU 1 DIMM DIMM DIMM DIMM DIMM DIMM DIMM DIMM 2A 2B 1A 1B 4A 4B 3A 3B 4 empty empty popu popu empty empty popu popu DIMMs lated lated lated lated 8 popu popu popu popu popu popu popu popu DIMMs lated lated lated lated lated lated lated lated CPU 1 CPU2 3 3 PCI bus coc PCI Express x8 Figure 3 PCI sl
10. System Board D2440 D2932 for RX330 S1 Technical Manual Edition June 2009 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual Your feedback helps us optimize our documentation to suit your individual needs Feel free to send us your comments by e mail to manuals ts fujtsu com Certified documentation according to DIN EN ISO 9001 2000 To ensure a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2000 cognitas Gesellschaft f r Technik Dokumentation mbH www cognitas de Copyright and Trademarks Copyright 2009 Fujitsu Technology Solutions GmbH All rights reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trademarks of their respective manufacturers Contents 1 introductio M TTE 2 Important notes so 22 ss xxu Rn 2 1 Holes ON safety au een 2 2 CE Cerilicae a uuucs xum 98x eek 2 3 Environmental protection 3 a i EM MEM TIT 3 1 OVOIVIEW ua 44a dca RO ORA EROR CR CA UR EC 3 2 Mail IBeImDEV 6 4 6 45 084 Go Pee ee GR k OR CR rE 3 3 PEIDUS cach xdeqeue5x qe ReEq SA Sq dus 3 4 Screen resolution 3 5 Temperature system monitoring 3 6
11. ances Waste from Electric and Electronic Equipment EU Directive RoMB RAID on Motherboard RSB Remote Service Board RST ReSeT RTC Real Time Clock SAS Serial Attached SCSI SATA Serial ATA SCSI Small Computer Systems Interface SDDC Single Device Data Correction SDRAM Synchronous Dynamic Random Access Memory SEL System Event Log D2440 D2932 RX330 S1 Technical Manual 31 Abbreviations SHDG Server Hardware Design Guide SMB System Management Bus SMM Server Management Mode SMP Symmetrical Multi Processing UHCI Unified Host Controller Interface USB Universal Serial Bus VGA Video Graphics Adapter VRD Voltage Regulator Down VRM Voltage Regulator Module WEEE Waste from Electric and Electronic Equipment EU Directive WfM Wired for Management WOL Wake up On LAN 32 Technical Manual D2440 D2932 RX330 S1
12. ase do not throw away the packaging We recommend that you do not throw away the original packaging in case you need it later for transporting Notes on dealing with consumables Please dispose batteries in accordance with local government regulations Do not throw batteries and accumulators into the household waste They must be disposed of in accordance with local regulations concerning special waste All batteries containing pollutants are marked with a symbol a crossed out rubbish bin on wheels In addition the marking is provided with the chemical symbol of the heavy metal decisive for the classification as a pollutant Cd Cadmium Hg Mercury Pb Lead Notes on labeling plastic housing parts Please avoid attaching your own labels to plastic housing parts wherever possible since this makes it difficult to recycle them D2440 D2932 RX330 S1 Technical Manual 11 Environmental protection Important notes Returning recycling and disposal The device may not be disposed of with household rubbish This appliance is labelled in accordance with European Directive 2002 96 EC concerning used electrical and electronic appliances waste electrical and electronic equipment WEEE The guideline determines the framework for the return and recycling of used appliances as applicable throughout the EU To return your used device please use the return and collection systems available to you You will find further information on this at
13. ets on the system board HT1000 South bridge HT2100 North bridge LSI 1068 SAS RAID controller iRMC with integrated graphic controller D2440 D2932 RX330 S1 Technical Manual Overview Features Broadcom 5715 Dual Gbit LAN controller Onboard Super I O controller PC87417 Internal connectors IDE primary connector 6 SAS connectors SATA connector USB connector front panel connector ATX power connector 2 CPU 12V power connectors fan1 3 Sys connector I2C connector PSU 2 hard disk signaling connectors IDTEMP connector safety switch connector battery holder External connectors 2 serial ports COM1 COM2 2 PS 2 interfaces for keyboard and mouse 2 USB 2 0 ports VGA port 2 RJ45 LAN ports Service LAN port PCI slots Slot for riser card PCI Express x8 slot BIOS features Phoenix BlOS Trusted Core Form factor 304 8 mm x 330 2 mm 14 Technical Manual D2440 D2932 RX330 S1 Features Main memory 3 2 Main memory The system board supports up to 32 Gibyte main memory 8 slots 4 banks with 2 modules are available for the main memory Each memory bank can be populated with 512 Mbyte only D2440 1 Gbyte 2 Gbyte or 4 Gbyte ECC DDR2 SDRAM memory modules The maximum main memory is 16 Gbyte for installation with one CPU and 32 GByte with two CPUs D2440 ECC DDR2 533 PC4300 or ECC
14. ic compatibility or your system Information on which system expansions are suitable can be obtained from the customer service centre or your sales outlet e The warranty expires if the device is damaged during the installation or replacement of system expansions D2440 D2932 RX330 S1 Technical Manual 7 Notes on safety Important notes N Batteries Components can become very hot during operation Ensure you do not touch components when making extensions to the system board There is a danger of burns Transmission lines to peripheral devices must be adequately shielded To the LAN wiring the requirements apply in accordance with the standards EN 50173 and EN 50174 1 2 As minimum requirement the use of a protected LAN line of category 5 for 10 100 MBps Ethernet and or of category 5e for Gigabit Ethernet is considered The requirements of the specification ISO IEC 11801 are to be considered Never connect or disconnect data transmission lines during a storm lightning hazard CAUTION Incorrect replacement of lithium battery may lead to a risk of explosion The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer It is essential to observe the instructions in chapter Replacing the lithium battery Technical Manual D2440 D2932 RX330 S1 Important notes Notes on safety Modules with electrostatic sensitive components Systems and components that
15. ion of the arrow 1 so that the lithium battery jumps out of its socket Remove the battery 2 Inserta new lithium battery of the same type into the socket 3 and 4 D2440 D2932 RX330 S1 Technical Manual 25 Abbreviations The technical terms and abbreviations given below represent only a selection of the full list of common technical terms and abbreviations Not all technical terms and abbreviations listed here are valid for the described system board AC Alternating Current ACPI Advanced Configuration and Power management Interface ANSI American National Standards Institute ASR amp R Automatic Server Recovery and Restart ATA Advanced Technology Attachment BBU Battery Backup Unit BIOS Basic Input Output System BMC Baseboard Management Controller CMOS Complementary Metal Oxide Semiconductor COM COMmunication port CPU Central Processing Unit D2440 D2932 RX330 S1 Technical Manual 27 Abbreviations DDR Double Data Rate DIMM Dual In line Memory Module DIP Dual In line Package DMI Desktop Management Interface DRAM Dynamic Random Access Memory ECC Error Correction Code EEPROM Electrical Erasable Programmable Read Only Memory EFI Extensible Firmware Interface EGB Elektrostatisch gef hrdete Bauteile EHCI Enhanced Host Controller Interface EMI Electromagnetic interference EMRL Embedded RAID Logic EMV Elektromagnetische Vertr glichkeit
16. might be damaged by electrostatic discharge ESD are marked with the following label A ta When you handle components fitted with ESDs you must observe the following points under all circumstances Figure 1 ESD label e You must always discharge yourself of static charges e g by touching a grounded object before working e The equipment and tools you use must be free of static charges e Remove the power plug from the power socket before inserting or removing boards containing ESDs e Always hold boards with ESDs by their edges e Never touch pins or conductors on boards fitted with ESDs e Use a grounding cable designed for this purpose to connect yourself to the System unit as you install remove the board e Place all components on a static safe base You will find a detailed description for handling ESD components in the relevant European or international standards EN 61340 5 1 ANSI ESD S20 20 D2440 D2932 RX330 S1 Technical Manual 9 CE certificate Important notes Notes about boards During installation deinstallation of the system board observe the specific instructions described in the service manual for the server Remove the plug from the mains outlet so that system and system board are totally disconnected from the mains voltage To prevent damage to the system board the components and conductors on it please take great care when you insert or remove boards Take great care to
17. monitored by this sensor run at maximum speed to achieve the greatest possible protection of the hardware Voltage monitoring The most important voltages are monitored When a voltage exceeds warning level high or falls below warning level low an alert will be generated Adequate measurements can be done by running agents Cover monitoring Opening of the cover causes an immediately shutdown of the system Unauthorised opening of the cover is detected even when the system is switched off However this will only be indicated when the system is switched on again System Event Log SEL All monitored events of the system board are recorded in the System Event Log They could be retrieved after a system reboot via ServerView 20 Technical Manual D2440 D2932 RX330 S1 Features Connectors and DIP switches 3 6 Connectors and DIP switches CPU2 J10 O us J25 J21 DIMM1B DIMM1A Im DIMM2B rm DIMM2A L J22 J17 55 DIMM4A Externe Anschl sse external connectors DIMM4B CPU 1 DIMM3A DIMM3B SS m J15 o 1234 Battery 276 J40 Er SATA1 SAS1 SAS2 SAS3 SAS4 SAS5 SAS6
18. o the Matrox graphic controller on the system board The Matrox graphic controller is integrated in the iRMC integrated Remote Management Controller Screen resolution Supported colors 640x480 8 bit 16 bit 24 bit 800x600 16 bit 24 bit 1024x768 16 bit 1152x864 8 bit 1280x1024 8 bit If you are using an external graphic controller you will find details of supported screen resolutions in the operating manual or technical manual supplied with the graphic controller 3 5 Temperature system monitoring Temperature and system monitoring aim to reliably protect the computer hardware against damage caused by overheating In addition any unnecessary noise is also prevented by reducing the fan speed and information is provided about the system status The temperature and system monitoring is controlled by an onboard controller The following functions are supported Temperature monitoring Measurement of the processor temperature the system board temperature by an onboard sensor and measurement of the ambient temperature by a temperature sensor Fan monitoring Fans that are no longer available blocked or sticky fans are detected D2440 D2932 RX330 S1 Technical Manual 19 Temperature system monitoring Features Fan control The fans are controlled according to temperature Sensor monitoring The removal of or a fault in a temperature sensor is detected Should this happen all fans
19. ots PCI slots The following table shows an overview of the PCI slots PCI slot Description 1 PCI Express x8 slot 2 4 Slots on riser card 1 or 2 16 Technical Manual D2440 D2932 RX330 S1 Features PCI bus Slots on riser card 1 PCI slot Description 4 PCI Express x8 slot 3 PCI X slot 66 MHz 2 PCI X slot 66 MHz inclusive ZCR option Slots on riser card 2 PCI slot Description 4 PCI Express x8 slot 3 PCI Express x4 slot 2 PCI X slot 66 MHz inclusive ZCR option Zero Channel RAID PCI X slot 2 is prepared for the operation of a Zero Channel RAID ZCR controller Such a ZCR controller has no ports for hard disk drives Installing the ZCR controller in this PCI X slot upgrades the SAS controller on the system board to a fully featured RAID controller Without this upgrade the SAS controller on the system board supports only RAID 0 and RAID 1 configurations PCI PCI X PCI Express interrupts Each device connected to a PCI bus a PCI X bus or PCI Express can use up to four interrupt signals depending on the functionality PCI and PCI X buses use four lines named INTA to INTD typically connected to all devices on the bus in order to periodically balance interrupt load An interrupt signal may thereby be used simultaneously by multiple devices interrupt sharing PCI Express devices send their interrupts through messages This avoid
20. s restrictions in wiring D2440 D2932 RX330 S1 Technical Manual 17 PCI bus Features The following interrupt signals are used in the system depending on the installed riser card 1 or 2 and the use of a ZCR controller With riser card 1 Slot device Property Interrupt signal VGA iRMC graphic PCI INTA LSI 1068 PCI X SAS controller PCI X INTC LAN BCM5715 Dual Channel Slot 4 PCle x8 Slot 3 PCI X 66 MHz PCI X INTD PCI X INTA PCI X INTB PCI X INTC Slot 2 PCI X 66 MHz inclusive ZCR PCI X INTA PCI X INTB PCI X INTC PCI X INTD Slot 1 PCle x8 With riser card 2 Slot device Property Interrupt signal VGA iRMC graphic PCI INTA LSI 1068 PCI X SAS controller PCI X INTC LAN BCM5715 Dual Channel Slot 4 PCle x8 Slot 3 PCle x4 Slot 2 PCI X 66 MHz inclusive ZCR PCI X INTA PCI X INTB PCI X INTC PCI X INTD Slot 1 PCle x8 If a ZCR controller has been installed in slot 2 the LSI1068 Controller is hidden in the device list and its interrupt signal goes no longer directly to the system Assignment of the PCI interrupts If you select Auto in the BIOS setup the interrupts are assigned automatically and no further settings are required 18 Technical Manual D2440 D2932 RX330 S1 Features Screen resolution 3 4 Screen resolution Depending on the operating system used the screen resolutions in the following table refer t