1. Only mix in sealed tubes and plates Sample material can be flung out of open inadequately sealed or unstable tubes and plates A When working with hazardous toxic and pathogenic samples always comply with the nationally specified safety environment Pay particular attention to personal safety gear gloves clothing glasses etc the extraction hood and the safety class of the laboratory 11 Specification 11 1 Adapter for microplates tubes and glass vials Q Instruments offers high precision adapter plates to allow a perfect fit for all kinds of tubes vials microplates and other different disposables The adapter plates are optimized for an excellent heat transfer to the disposables and enhance the uniformity over all wells and the heat up time The exchange of adapter plates can be performed very easily within one minute If you need an adapter plate for specially shaped micro plates tubes or vials so please send us additional specific information about your used sample container manufacturer description article number You will receive your special formed adapter plate Q Instruments QUANTIFOIL Instruments GmbH 10 Operating Manual BioShake 3000 11 2 Technical Specification Changeable adapter plates for sample container Microplates 96 384 and 1536 well microplates deep well plates PCR plates Tubes 0 2 0 5 1 5 2 0 ml standard microcentrifuge tubes Glass vials 2 0 and 4 0 ml glass vials others on
2. Claims for damage in transit are directed to the freight carrier upon receipt Please use the online form for registration of your appliance and service www ginstruments com service Your completed data will serve as registered certificate of guarantee for our extended guaranteeing and will assure optimal service Please keep your sales slip for a possible warranty case which must be presented then Your personal data will not be given to third persons Q Instruments QUANTIFOIL Instruments GmbH 5 Operating Manual BioShake 3000 4 Delivery Parts Part 1 BioShake 3000 incl 1x 24 VDC cable prewired cable length 2 m incl 1x RS 232 cable prewired cable length 2 m Part 2 Power supply Part 3 Power cord 1x Europe and 1x country specific design Part 4 Operating manual calibration certificate allen key integration manual no picture 5 Installation Unpack and carefully check the instrument Report any damage or missing items to your distributor If no damage is found place the device up on a stable horizontal surface Place an adapter on the shaker chapter 6 Changing of adapter plates if necessary Adjust the shaker to your Microplate Type chapter 7 Adjustment to the Microplate Plug in the RS232 cable into a free port of your computer Plug the external power supply 2 into the 24 V socket of the BioShake Plug the power cord 3 into the power supply 2 and into the wall socket The instrument w
3. General hazard point 6 Warning Injury from rapidly rotating holder Injury from rapidly rotating imbalance compensation Injury from flying tubes and plates 7 Warning Injury from sample material being flung out Injury from incorrect vortexing 8 Warning Damage due to incorrect power supply 9 Caution Damage to the display from mechanical pressure Severe vibration 10 Caution Damage to electronic components caused by spilled liquids Damage to electronic components from condensation 11 Caution Poor safety due to missing operating manual Caution when using aggressive chemicals 12 Please start even with minimal mixing frequencies to avoid overloading 13 Only mix in sealed tubes and plates Sample material can be flung out of open inadequately sealed or unstable tubes and plates 14 When working with hazardous toxic and pathogenic samples always comply with the nationally specified safety environment 15 Please use the original power supply delivered by QUANTIFOIL Instruments 16 Please use the original accessories recommended by QUANTIFOIL Instruments Q Instruments QUANTIFOIL Instruments GmbH 3 Operating Manual BioShake 3000 Pay particular attention to personal safety gear gloves clothing glasses etc the extraction hood and the safety class of the laboratory Read this section carefully and follow the instructions before beginning installation and any procedure The unit must be placed on
4. length 2 m 1x documentation 1x calibration certificate Microplate thermoshaker for robots Automatic Edge Locking Mechanism ELM for robotic gripping Mixing from 0 3 000 rpm orbit 2 0 mm temperature control from RT 99 C RS232 1x BioShake 3000 T elm 1x power supply 110 240 VAC 24 VDC 2x power cords Europe amp country specific 1x 24 VDC cable fixed length 2 m 1x RS232 cable fixed length 2 m 1x documentation 1x calibration certificate Orbital shaker for 384 amp 1536 well microplates Automatic Edge Locking Mechanism ELM for robotic gripping Mixing from 0 5 000 rpm orbit diameter 1 2 mm RS232 1x BioShake 5000 elm 1x power supply 110 240 VAC 24 VDC 2x power cords Europe amp country specific 1x 24 VDC cable fixed length 2 m 1x RS232 cable fixed length 2 m 1x documentation 1x calibration certificate Adapters are not included in delivery and have to be ordered separately Accessories Software order ro 1808 9013 1808 9120 1810 0061 1810 0071 1810 0072 1810 0073 1811 0200 Description Grounding set for BioShake universal USB RS232 Converter Digitus DA 70156 USB serial adapter USB 2 0 Daisy Chain Box 4 Moxa 4 port Connects 1 4 BioShake serial devices via USB Port to a PC Moxa 8 port Connects 1 8 BioShake serial devices via USB Port to a PC Moxa 16 port Connects 1 16 BioShake serial devices via USB Port to a PC SILA Driver for BioShake compliant and approve
5. 2 m 1x RS232 cable fixed length 2 m 1x documentation 1x calibration certificate Microplate orbital shaker for robots Automatic Edge Locking Mechanism ELM for robotic gripping Mixing from 0 3 000 rpm orbit diameter 2 0 mm RS232 1x BioShake 3000 elm 1x power supply 110 240 VAC 24 VDC 2x power cords Europe amp country specific 1x 24 VDC cable fixed length 2 m 1x RS232 cable fixed length 2 m 1x documentation 1x calibration certificate BioShake 3000 elm DWP Description Scope of delivery BioShake 3000 T Description Scope of delivery BioShake 3000 T elm Description Scope of delivery BioShake 5000 elm Description Scope of delivery Orbital Shaker for Deep Well Plates DWP Specially adapted for 0 5 2 2 ml DWP Automatic Edge Locking Mechanism ELM for robotic gripping Mixing from 0 3 000 rom orbit diameter 2 0 mm RS232 1x BioShake 3000 elm DWP 1x power supply 110 240 VAC 24 VDC 2x power cords Europe amp country specific 1x 24 VDC cable fixed length 2 m 1x RS232 cable fixed length 2 m 1x documentation 1x calibration certificate Universal thermoshaker for robots For using with microplates tube glass vials or others Mixing from 0 3 000 rpm orbit 2 0 mm temperature control from RT 99 C RS232 1x BioShake 3000 T 1x power supply 110 240 VAC 24 VDC 2x power cords Europe amp country specific 1x 24 VDC cable fixed length 2 m 1x RS232 cable fixed
6. Well Plate Axygen 96 2 0 ml round bottom P DW 20 C 1808 1171 Adapter for Storage Plate Abgene 96 2 2 ml MARK II square well AB 09032 1808 1172 Adapter for Deep Well Plate Abgene 96 0 8 ml round well AB 0765 AB 0859 1808 1181 Adapter for Mega Block Sarstedt Megablock 96 2 2 ml 82 1972 002 1808 1191 Adapter for Storage Plate HJ Bioanalytik 96 1 2 ml riplate low profile 750289 1808 1201 Adapter for Storage Plate Corning 96 320 ul V bottom 3342 3347 3357 3363 3894 3898 1808 1211 Adapter for Masterblock Greiner 96 1 0 ml U bottom 78020x 78026x Thermo adapter for centrifuge tubes with conical shape 1808 1061 Adapter for tubes 24x 2 0 ml or 15x 0 5 ml 1808 1062 Adapter for tubes 24x 1 5 ml or 15x 0 5 ml 1808 1063 Adapter for tubes 40x 0 5 ml or 28x 0 2 ml 1808 1064 Adapter for tubes 96x 0 2 ml 1808 1067 Adapter for lysis tubes 35x 0 5 2 0 ml 10 2 mm 1808 1093 Adapter for FALCON tubes 4x 50 ml or 2x 15 ml 1808 1094 Adapter for FALCON tubes 12x 15 ml Accessories for tube adapter 1808 1511 IQ Rack Cover for adapter 24x 1 5 2 0 ml tubes Thermo adapter for tubes vials with cylindrical shape 1808 1069 Adapter for glass vials 35x 2 0 ml 10 8 mm 1808 1071 Adapter for glass vials 30x 2 0 ml 12 mm 1808 1072 Adapter for glass vials 20x 4 0 ml 15 mm 1808 1073 Adapter for glass vials 20x 4 0 ml 17 mm 1808 1074 Adapter for glass vials 20x 6 0 ml 19 mm 1808 1085 Adapte
7. request 200 to 3 000 rpm microplates Mixing frequency 200 to 1 800 rpm tubes glass vials Mixing orbit constant 2 mm diameter Speed setting resolution linear increments Mixing regulation accuracy 25 rpm Home position Yes self positioning within 5 sec Home position accuracy 0 1 mm Electronic control board Completely accommodated in the shaker non external components Controller Microcontroller 8 Bit RISC Prozessor Operation control Remote controlled User interface RS232 interface 2 0 m connecting cable Electrical Operating Voltages 24 V DC input 75 Watt Power supply External power supply unit 100 240 V AC 50 60 Hz Properties Housing Material Aluminum anodized Environment operating range 5 C to 45 C 80 max relative humidity 142 mm x 99 mm x 48 2 mm 5 59 in x 3 897 in x 1 8976 inches Weight 1 5 kg 3 3 Ibs Dimensions W x D x H Technical specifications subject to change Operating Manual BioShake 3000 12 CE Certificate of Conformity TH RINGEN ZERTIFIKAT CERTIFICATE Konformit tsbest tigung Certificate of Conformity Registrier Nr Registered No 074 13 3510 B Zeichen des Antragstellers Antragsdatum Aktenzeichen Pr fbericht Nr g ltig bis Reference of Applicant Date of Applicaton Fie Reference Test Report No valid wart 27 09 2013 3510 3280 13 3280 13 01 30 09 2015 Hiermit wird best tigt dass das nachfolgend genannte Produkt den Sicherheitszi
8. shown above Contact the factory at the address above for a Return Material Authorization RMA number before returning the product QUANTIFOIL Instruments shall be the sole judge of the warrant ability of alleged product defects Products that are returned for warranty examination and that are found to be non warrantable are chargeable and are returned freight collect A copy of a purchase order with the amount of the charge must be received by QUANTIFOIL Instruments either by mail or by FAX before any equipment is returned Warrantable products are repaired or replaced at no charge and returned freight prepaid THIS EXPRESS WARRANTY EXCLUDES ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PURPOSE QUANTIFOIL INSTRUMENTS GmbH SHALL NOT BE LIABLE FOR WARRANTY IN ANY AMOUNT EXCEEDING THE PURCHASE PRICE OF THE GOODS QUANTIFOIL INSTRUMENTS GmbH SHALL NOT BE LIABLE FOR ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES WHETHER IN CONTRACT TORT OR OTHERWISE The buyer acknowledges that he she is not relying on the seller s skill or judgment to select or furnish goods suitable for any particular purpose and that there are no warranties that extend beyond the description on the face hereof This warranty extends only to the original purchaser and shall not apply to any products or parts that have been subject to misuse neglect accident or abnormal conditions or operations
9. system Please call the service line Sensor with the requested ID is not found while working Please call the service line Errors caused by a faulty temperature measurement while working Please call the service line O 5 2 3 D 3 n O Cc gt Z 2 2 3 D l n Q 3 oO I co Operating Manual BioShake 3000 10 Tips for shaker operation A wide variety of well plates are commercially available To ensure that the plates are positioned securely in the plate Sir baoe Newion amo 1887 holder they must correspond with the ANIS SBS Standard for Microplates H If the filled plate has a weight of more than 80 g then the O 2N maximum rated shaking frequency of 3 000 rom may not be attainable with a safety stand Select a lower shaking 2 frequency in this case However there is no risk of damage F mo r to the BioShake even if the weight is too high then the shaking action stops due to excessive weight or excessive shaking frequencies As soon as you reduce the frequency Angular frequency orbital mixing the unit will stand firm radius 7 and centripetal force F are important values for efficient mixing Maximum shaker platform load 500 g filled well plate The shaker is driven by a maintenance free brushless motor which enables silent operation and constant shaking speed independent of the load IMPORTANT NOTES Please start even with minimal mixing frequencies to avoid overloading
10. BioShake QUANTIFOIL Instruments GmbH Trademarks of third parties may appear in this document when referring to those entities or their products or services All registered names trademarks etc used on this document even when not specifically marked as such are not to be considered unprotected by law Any names and trademarks not specifically marked or listed are property of the respective owner Further trademarks used in this website and catalogs Brand BRAND GmbH Co KG Corning Corning Inc Eppendorf Eppendorf AG Thermomixer Eppendorf AG Eppendorf Tubes Eppendorf AG Eppendorf twin tec Eppendorf AG Falcon Becton Dickinson And Company Greiner Greiner Labortechnik GmbH MOXA Moxa Inc NUNC Nunc NS Corporation SILA Rapid Integration Association Consortium Standardization in Lab Automation Windows Microsoft Corporation Technical specifications are subject to change without notice All rights reserved Q Instruments QUANTIFOIL Instruments GmbH 16
11. BioShake 3000 Operating Manual Q Instruments QUANTIFOIL Instruments GmbH Operating Manual BioShake 3000 Table of contents OONOOOFWND Q Instruments QUANTIFOIL Instruments GmbH Sa Oly and GO AU OH ee er E E EA 3 General Morna O eisene 5 WAAN einstellen e 5 DIVE all arten este 6 MN STAN ATION see esse Nessie 6 Changing ot adapter Blales n nn ee a 7 Adjustment to the miclopl ate un esas ee ateussanGyeteacinavavedeuresetewseesecee 8 ODS AMON ae ee ee see 9 ETON COMMU Ol Een as E T E TE 9 11PS 107 Shaker ODEFALlONn nee nee en 10 SPEENEANON ee es een dee 10 11 1 Adapter for microplates tubes and glass vials nsnssensneeeneeeenrreerrnresrrnrrsrnnne 10 11 2 Technieal Speeiflicalon s au ee 11 GE Gerlilficate Of COnmonmity aaa ieee adeeeee 12 BioShake Gontrol test8olwaren a ssenn elek 13 Maintenant Saree haa anh ee Er erden 13 Ordeting lnformalions sessn ansehe 14 SUPPO eke een neta er a ae ae ee ee a ee een 16 Operating Manual BioShake 3000 1 Safety and Caution AA AAA A 1 Do not operate the device in rooms where work is being carried out with explosive substances 2 Do not use this device to process any explosive radioactive or highly reactive substances 3 Do not use this device to process any substances which could create an explosive atmosphere 4 Danger Electric shock from damage to device power cable Danger Lethal voltages inside the device 5 Warning
12. FOIL Instruments Using spare parts or disposables which we have not recommended can reduce the precision accuracy and life of the BioShake QUANTIFOIL Instruments do not honour any warranty or accept any responsibility for damage resulting from such action 16 Support P lease contact Q Instruments for additional information and availability about the BioShake If you have any problems with the control of the BioShake please contact the Q Instruments support team We provide a range of technical material e g application notes bulletins instruction manuals and selection and use guides that support our products and key applications All of our technical documents can be viewed and printed Many documents are available as PDF Portable Document Format files which may be downloaded http www qinstruments com en service downloads html QUANTIFOIL Instruments GmbH Loebstedter Str 101 07749 Jena Germany Phone 49 0 3641 876 12 0 Fax 49 0 3641 876 12 99 www Qlnstruments com info QInstruments com DISCLAIMER LEGAL NOTICES AND TRADEMARKS All document design text graphics the selection and arrangement thereof and all other materials in this document are copyright QUANTIFOIL Instruments GmbH Q Instruments is owner of numerous patents worldwide Please respect our intellectual property Q Instruments trademarks are recognised worldwide Please respect our trademarks as we will vigorously protect their proper usage
13. a horizontal solid work space The device must be saving from shocks and falling The unit must be placed in sufficient distance to heat registers or radiators to ensure ambient temperature conditions in accordance with the technical specifications Use the normal care and precaution one would use with any electrical appliance Be sure to use a power cord with the same rating and of the same type three wire with neutral conductor as the one supplied with the instrument Ensure that voltage and frequency of your power source match the input voltage and frequency inscribed on the electrical rating label of the power supply AC DC adaptor and that the output voltage matches the rating of the equipment The AC DC adaptor is designed to work with a single phase power system having a grounded neutral conductor If you are not sure what type of power is supplied to your building contact your facilities manager As BioShake is an electrical device do not spill large quantities of liquid onto the device Do not use it in an explosive atmosphere As parts of the device may generate electric magnetic or electromagnetic fields keep parts away that may be affected e g data storage units BioShake is capable of heating the plate surface up to 100 C This temperature is high enough to cause serious burns if touched Use extreme caution at all times Never leave your unit accessible to others when it is hot Never touch the plate surface unles
14. d driver according SILA standard Q Instruments QUANTIFOIL Instruments GmbH tg Operating Manual BioShake 3000 Adapter Thermo adapter only for BioShake XP BioShake iQ BioShake 3000 BioShake 3000 T BioShake 3000 T elm Ce U U U U Thermo adapter for micro well plates amp PCR plates 1808 1021 Adapter for micro well plate Flat bottom standard e g Nunc 269620 Greiner 781101 1808 1022 Adapter for micro well plate Flat bottom High Base e g Greiner HiBase 78407x 78410 1808 1024 Adapter for micro well plate Flat bottom Low Base e g Aurora storage plate Alere ArrayStrip 1808 1031 Adapter for micro well plate 96 well round bottom type 1 e g Corning 3367 3789 1808 1032 Adapter for micro well plate 96 well round bottom type 2 e g Greiner NUNC Matrix plates 1808 1041 Adapter for PCR Plate 96 well e g Eppendorf twin tec 0030 128 672 1808 1051 Adapter for PCR Plate 384 well e g Eppendorf twin tec 0030 128 532 Thermo adapter for deep well plates amp storage plates 1808 1121 Adapter for Deep Well Plate Eppendorf 96 1000 ul 0030 503 209 1808 1131 Adapter for Deep Well Plate Eppendorf 96 500 ul 0030 501 101 1808 1141 Adapter for Deep Well Plate BRAND 96 1100 ul U bottom 701350 1808 1151 Adapter for Deep Well Plate NUNC 96 2000 ul 278743 278752 1808 1161 Adapter for Deep Well Plate Axygen 96 0 6 ml V bottom P DW 500 C 1808 1162 Adapter for Deep
15. elen der Richtlinie des Rates vom 12 Dezember 2006 zur Angleichung der Rechtsvorschriften der Mitgliedsstaaten betreffend elektrische Betriebsmittel 2006 95 EG entspricht We hereby certify that the product mentioned below meets the safely destinations of the council directive of 12 December 2006 on the approximation of the laws of the member states relating to electrical appliances 2006 94 EC Hersteller QUANTIFOIL Instruments GmbH Manufacturer name Loebstedter Stra e 101 07745 Jena Erzeugnis Typ Thermosch ttler Product type Typ BioShake 3000 T elm Technische Beschreibung 24VDC 100W technical description mit Netzteil Sunny Computer Technology Europe Typ SYS1250 A324 nicht Bestandteil der Pr fung Pr fgrundlagen DIN EN 61010 1 2002 08 B1 2002 11 B2 2004 11 Tested according to DIN EN 61010 2 010 2004 06 DIN EN 61010 2 051 2004 07 Dieses Zerifikat best tigt das Ergebnis einer einmaligen Untersuchung an dem zur Pr hang worgelegien Erzeugnismuster Es siell kein allgemeing ltges Linel ber die Eigenschaften der Erzeugnisse aus der laufenden Ferigung dar Eas ER pilaar EN oaa de vom vorgeliegien Erseugnismuster abweichen oder wenn sich de Pr fgrungagen ndern Auch wenn sich vorstehend genannte Produkte nicht ndern wird mt og Giltigkeitsdatum dieses Zertlikat automatisch ung ltig Es berechtigt nicht zur F hrung eines Prifzeichens oder des Logos des TOV Th ringen Eine Verifienfichung dieses Zertificaies ist ohne schr
16. f BioShake devices in lab automation systems 9 Error control All BioShake devices as new version 2012 have internal algorithms and sensors for monitoring operating parameters and error detection Any errors are sending out via RS232 communication interface Those are easier to detect and localize indicator lights that light up either or are disabled Boot process when switching on or reset Only red indicator light Failure free operation Only green indicator light Green and red indicator lights In case of failure atthe same time In case of failure the error list should read out via RS232 command getErrorList lt CR gt to help detect the error more precisely Error Value Description Mixing function Error by the DC motor controller Error due speed failure for example happens through mechanical locking Errors caused by an uninitialized shaker or incorrect initialization parameters after switch on Please see the service manual to start a special initialization routine for optimization of motor parameters Errors caused by unsuccessful initialization routine Please see also the service manual Errors caused by not achieving of the home position at the stop command routine Please call the service line Temperature control Error due failed answers from temperature sensors or incorrect internal settings of temperature sensors Please call the service line Error due temperature communication bus
17. iftliche Genehmigung der Pr fstelle nicht gestattet Hinsichtlich der c g grundegendan Anforderungen und zu bericksichtigender Prifgrundiagen git fir die Erzeugnisse der laufenden Produkton die aktuelle Rechtslage zum Zeitpunkt ihres Inverkehrbringens This certificata conis the res of a nonrecurring testing of fhe presented objec sample te ya s Ieee ni oh an This Sure is nmol valg fmm iara for products which deviate fom the submitted prmduction sampla or if fe test basis changes Even d points as afore speciied do not change Mis cerfiicahr becomes automaticaly inaid with above mentioned dale of validity It does not legitimate fo use a test mark or the logo of TOV Th ringen The publishing of thal certificate needs the written approval of Ie testing centre Regarding fe alora mantioned basic requiremants and feasting specifications fo consider the products of fhe curnea fabrication have fo comply wih ihe legal san up hdede by its dime of placing on the manat Arnstadt den 30 09 2013 TUV Thiringen Anlagentechnik GmbH amp Co KG Pr fstelle f r Ger tesicherheit Ichtersh user Str 32 99310 Arnstadt Tel 03628 598 370 Fax 03628 598 371 gsluev thueringen de Pr flaboratorium u Zertifizierungsstelle PT TCU CCPC CTT Teer eT TTT Te eer ee Dipl Ing FH S Thron Sachverstandiger Dieses Zertifikat besteht aus this certificate consists of 1 Blatt sheet The CE certified instrument BioShake 3000 T elm is identical in con
18. ill do a self test Now the instrument is ready to accept data s from the computer To integrate the instrument into a robotic system please refer to the document Integration Manual Integration of BioShake instruments in lab automation systems lt is advisable to carry out a test run at maximum speed to ensure that the device does not move while mixing Q Instruments QUANTIFOIL Instruments GmbH 6 Operating Manual BioShake 3000 6 Changing of adapter plates A If the security cover plate or an adapter plate is already be mounted please remove it first To change the adapter plates please follow the subsequent steps 1 2 3 4 Switch off the power supply for the instrument Remove all sample carriers tubes vials microplates etc Loosen the 3 torx screws A 1 A 2 and A 3 by using the supplied screwdriver Torx size 8 rotate left Take off the adapter plate B 2 straight up and put it on a clean soft surface Mounting of the new adapter plate 1 Please take care to a clean dirt free and particle free operation 2 Insert the new adapter plate straight into the impression into the plate holder B 1 3 Check the fixed position 4 Fix all torx screws A 1 A 2 und A 3 using clockwise rotation Please take care to uniform controlled tightening of screws to ensure a good fit 5 Please take care to good and tight fit of sample carriers tubes vials microplates etc 6 Turn On the p
19. ower supply of the instrument A Heavier blocks may limit the shaking speed Q Instruments QUANTIFOIL Instruments GmbH Operating Manual BioShake 3000 7 Adjustment to the microplate 1 Insert the two spring plungers 1 into the treated screw holes in the corner area of the plate holder 4 by turning it clockwise with the delivered allen key 3 Insert the microplate 5 you want to use Turn the knurled nuts 2 by hand a few turns in clockwise direction A Turn the spring plunger 1 clockwise A until the ball is retracted completely Turn the spring plunger 1 counterclockwise B for 45 90 Turn the knurled nuts 2 by hand clockwise A until it sits tight now the shaker is ready to be used with the microplate of your choice BARON Q Instruments QUANTIFOIL Instruments GmbH 8 Operating Manual BioShake 3000 8 Operation The BioShake is designed for shaking of liquids in tissue culture plates microplates tubes and vials The microplate or tubes have to place on the shaker platform of the BioShake The liquid to be shaken is introduced into the wells or tubes The automatic start up function of the unit ensures a gradual start of the shaking process without sample splashing The drive is absolutely wear free and maintenance free To integrate the instrument into a robotic system please refer to the document Integration o
20. r for 24x Alere ArrayTubes 1 5 ml Customized adapters 1808 1000 Customized adapters are available on request Service material and spare parts Order no Description TI Service material 1808 9001 Set of axial bearing balls for BioShake set of 3 pieces 1808 9002 Set of O rings coated special slide way coating 13x2mm set of 3 pieces 1808 9003 Service Pack for BioShake contents 1808 9001 1808 9002 1808 9004 Service set of ELM Pins for BioShake 3000 elm set of 4 pieces 1808 9009 Service set of ELM Pins for BioShake 3000 T elm set of 4 pieces 1808 9005 Service set of mass balance elements for BioShake Spare parts 1808 9011 External power supply unit 100 240 V AC 50 60 Hz 24 V DC 120 W 1808 9101 Power cord with 3 pin plug clover leaf Europe 1808 9102 Power cord with 3 pin plug clover leaf Switzerland 1808 9103 Power cord with 3 pin plug clover leaf UK 1808 9104 Power cord with 3 pin plug clover leaf Italy 1808 9110 Power cord with 3 pin plug clover leaf USA 1808 9111 Power cord with 3 pin plug clover leaf Japan 1808 9112 Power cord with 3 pin plug clover leaf China 1808 9113 Power cord with 3 pin plug clover leaf Korea 1808 9114 Power cord with 3 pin plug clover leaf Australia Q Instruments QUANTIFOIL Instruments GmbH 15 Operating Manual BioShake 3000 Please use the original accessories recommended by QUANTIFOIL Instruments Please use the original power supply delivered by QUANTI
21. s you are sure it is cold Use oven gloves if necessary Do not unscrew any part of BioShake except different blocks Do not make any mechanical or electrical modifications to the equipment Never do anything else with BioShake as intended in this manual Noncompliance of the safety instructions may lead to device damage loss of warranty and may cause serious personal injury as well as death Q Instruments QUANTIFOIL Instruments GmbH Operating Manual BioShake 3000 2 General Information Warning Injury from sample material being flung out Sample material can be flung out of open inadequately sealed or unstable wells plates and tubes e Only mix in sealed tubes and plates e When working with hazardous toxic and pathogenic samples always comply with nationally specified safety environment Pay particular attention to personal safety gear gloves clothing glasses etc the extraction hood and the safety class of the laboratory When setting mixing frequency start from slower to faster speed settings 3 Warranty QUANTIFOIL Instruments warrants products manufactured by it to be free from defects in material or workmanship under normal use and service for a period of 2 years from date of shipment This warranty is specifically limited to the replacement or repair of any such warrantable defects without charge when the complete product is returned to QUANTIFOIL Instruments GmbH freight prepaid at the address
22. struction with all products of the BioShake 3000 series Q Instruments QUANTIFOIL Instruments GmbH 12 Operating Manual BioShake 3000 13 BioShake Control test software Global BioShake Control is a small Windows based program for your PC to start using the shaker in moments and to exercise all shaker features Installation 1 gt N op p tart Download the software from the download area http www qinstruments com en service downloads html Check the actual version of Windows Net Framework 4 Use this link for actual version www microsoft com en us download details aspx id 17718 Copy the BioShakeControl exe 1 1 MB to your PC Plug in the RS232 cable from the single BioShake or Daisy Chain Box into a free port of your computer If necessary use a USB RS232 converter Plug the external power supply supplies into the 24 V socket of all used BioShake Plug the power cord s into the power supply supplies Switch On all BioShake devices at the same time The instrument s will do a self test Start the program BioShakeControl exe through a double click Now the instruments and software are ready to work Select the right COM port and click the button open 11 12 13 The software starts the initialization routine for determining all connected devices Now the user can set parameters start and stop for a single device In global section the user can control all de
23. vices with global commands 14 Maintenance The device is maintenance free Before cleaning the BioShake disconnect the power cord lf contaminated the device may be cleaned using a mild soap solution and water or an alcohol based disinfectant Do not use another cleaning solution If you have any questions about cleaning please contact your distributor or directly QUANTIFOIL Instruments Should it become necessary to repair the equipment it should be returned to an authorized servicing agent The equipment must be clean and free from harmful substances Always ship the shaker well packed preferably in the original shipping container in order to avoid damage to the unit en route For more details how to service the device please refer to the document A Service Manual BioShake Q Instruments QUANTIFOIL Instruments GmbH 13 Operating Manual BioShake 3000 15 Ordering Information BioShake single modules for automation Order no Description U 1808 0016 1808 0017 1808 0516 1808 0517 1808 2017 BioShake 3000 Description Scope of delivery BioShake 3000 elm Description Scope of delivery Universal orbital shaker for robots For using with microplates tube glass vials or others Mixing from 0 3 000 rpm orbit diameter 2 0 mm RS232 1x BioShake 3000 1x power supply 110 240 VAC 24 VDC 2x power cords Europe amp country specific 1x 24 VDC cable fixed length