1. ac CMRR 70 dB Integration Time and Normal Mode Rejection2 100 plc 1 67 s 2 s 60 dB 10 plc 167 ms 200 ms 60 dB 1 plc 16 7 ms 20 ms 60 dB lt 1 plc 3 ms or 800 ps 0 dB Operating Characteristics Function Digits Reading s deV dclpand 67 0 6 0 5 Resistance 67 6 5 5 60 50 5 300 4 1000 acV acl 6 0 15 slow 3 Hz 6 1 medium 20 Hz 6 10 fast 200 Hz 67 50 Frequency 6 1 or Period 54 98 4 2 80 Frequency and Period Configuration rates 26 s to 50 s Autorange rate dc Volts gt 30 s ASCII readings to RS 232 55 s ASCII readings to RS 232 1000 s Maximum internal trig rate 1000 s Max ext trig rate to mem 1000 s Triggering and Memory Reading HOLD Sensitivity 10 1 0 1 or 0 01 of range Samples Trigger 1 to 50 000 Trigger Delay 0 to 3600 s 10 us step size External Trigger Delay lt 1 ms External Trigger Jitter lt 500 us Memory 512 readings Math Functions NULL min max average dBm dB limit test with TTL output Standard Programming Languages SCPI IEEE 488 2 Agilent 3478A Fluke 8840A 42A Accessories Included Test lead kit with probe alligator and grabber attachments Operating manual service manual test report and power cord General Specifications Power Supply 100 V 120 V 220 V 240 V 10 Power Line Frequency 45 Hz to 66 Hz and 360 Hz to 440 Hz Automatically sensed at power on Power Consumption 25 VA peak 10 W averag
2. 0 0020 0 0005 0 008 0 001 0 010 0 001 0 0006 0 0001 100 0000 kO 10 pA 0 0020 0 0005 0 008 0 001 0 010 0 001 0 0006 0 0001 1 000000 MO 5 0 pA 0 002 0 001 0 008 0 001 0 010 0 001 0 0010 0 0002 10 00000 MO 500 nA 0 015 0 001 0 020 0 001 0 040 0 001 0 0030 0 0004 100 0000 MO 500 nA 10 MO 0 300 0 010 0 800 0 010 0 800 0 010 0 1500 0 0002 DC current 10 00000 mA lt 0 1 V Burden Voltage 0 005 0 010 0 030 0 020 0 050 0 020 0 0020 0 0020 100 0000 mA lt 0 6 V 0 010 0 004 0 030 0 005 0 050 0 005 0 0020 0 0005 1 000000 A lt 1 0 V 0 050 0 006 0 080 0 010 0 100 0 010 0 0050 0 0010 3 00000 A lt 2 0 V 0 100 0 020 0 120 0 020 0 120 0 020 0 005 0 0020 True rms 1 000000 A 3 Hz 5 Hz 1 00 0 04 1 00 0 04 1 00 0 04 0 100 0 006 AC current4 5 Hz 10 Hz 0 30 0 04 0 30 0 04 0 30 0 04 0 035 0 006 10 Hz 5 kHz 0 10 0 04 0 10 0 04 0 10 0 04 0 015 0 006 3 00000 A 3 Hz 5 Hz 1 10 0 06 1 10 0 06 1 10 0 06 0 100 0 006 5 Hz 10 Hz 0 35 0 06 0 35 0 06 0 35 0 06 0 035 0 006 10 Hz 5 kHz 0 15 0 06 0 15 0 06 0 15 0 06 0 015 0 006 Frequency 100 mV to 3 Hz 5 Hz 0 10 0 10 0 10 0 005 or period8 750 V 5 Hz 10 Hz 0 05 0 05 0 05 0 005 10 Hz 40 Hz 0 03 0 03 0 03 0 001 40 Hz 300 kHz 0 006 0 01 0 01 0 001 Continuity 1000 0 Q 1 mA test current 0 002 0 030 0 008 0 030 0 010 0 030 0 001 0 002 Diode test 1 0000 V 1 mA test current 0 002 0
3. 010 0 008 0 020 0 010 0 020 0 001 0 002 1 Specifications are for 1 hr warm up and 6 digits slow ac filter 2 Relative to calibration standards 3 20 over range on all ranges except 1000 Vdc and 750 Vac ranges 4 For sinewave input gt 5 of range For inputs from 1 to 5 of range and lt 50 kHz add 0 1 of range additional error 5 750 V range limited to 100 kHz or 8 x 107 Volt Hz 6 Typically 30 of reading error at 1 MHz 7 Specifications are for 4 wire ohms function or 2 wire ohms using Math Null Without Math Null add 0 2 Q additional error in 2 wire ohms function 8 Input gt 100 mV For 10 mV to 100 mV inputs multiply of reading error x10 9 Accuracy specifications are for the voltage measured at the input termi nals only 1 mA test current is typical Variation in the current source will create some variation in the voltage drop across a diode junction 212 6 mm 348 3 mm NJ Measurement Characteristics DC Voltage Measurement Method Continuously integrating multi slope III A D converter A D Linearity 0 0002 of reading 0 0001 of range Input Resistance 10 MQ or 0 1 V 1 V 10 V ranges Selectable gt 10 000 MO 100 V 1000 V ranges 10 MO 1 Input Bias Current lt 30 pA at 25 C Input Protection 1000 V all ranges dcV dcV ratio accuracy Vinput Accuracy V Accuracy relevance True RMS AC Voltage Measurement Method AC co
4. 30 A current shunt E2308A 5 k thermistor probe Y1133A Low thermal external digital multimeter scanning kit Rack Mount Kits 34190A Rackmount kit designed for use with only one instrument mounted on either the left or the right side of the rack 34191A 2U Dual flange kit secures the instrument to the front of the rack This kit can be used with the 34194A dual lock link kit to mount two half width 2U height instruments side by side 34194A Dual lock link kit recommended for side by side combinations and includes links for instruments of different depths This kit can be used with the 34191A 2U dual flange kit to mount two half width 2U height instruments side by side Other Accessories 34131A Hard transit case 34161A Accessory pouch 34398A RS 232 cable 9 pin f to 9 pin f E5810A LAN GPIB gateway www agilent com quality Bey Agilent Email Updates www agilent com find emailupdates Get the latest information on the products and applications you select LAI www lxistandard org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems Agilent is a founding member of the LXI consor tium Agilent Channel Partners wwagilent com find channelpartners Get the best of both worlds Agilent s measurement expertise and product breadth combined with channel partner convenience www agilent com www agilent com find 34401A For more information on Agilent Tech nolog
5. 4401A provides a combination of resolution accuracy and speed that rivals DMMs costing many times more 6 7 digits of resolution 0 0015 basic 24 hr dcV accuracy and 1 000 readings s direct to GPIB assure you of results that are accurate fast and repeatable Use It on Your Benchtop The 34401A was designed with your bench needs in mind Functions com monly associated with bench operation like continuity and diode test are built in A Null feature allows you to remove lead resistance and other fixed offsets in your measurements Other capabilities like min max avg readouts and direct dB and dBm measurements make checkout with the 34401A faster and easier Agilent 34401A Multimeter Uncompromising Performance for Benchtop and System Testing Data Sheet The 34401A gives you the ability to store up to 512 readings in internal memory For trouble shooting a reading hold feature lets you concentrate on placing your test leads without having to constantly glance at the display Use It for Systems Testing For systems use the 34401A gives you faster bus throughput than any other DMM in its class The 34401A can send up to 1 000 readings s directly across GPIB in user friendly ASCII format You also get both GPIB and RS 232 interfaces as standard features Voltmeter Complete and External Trigger signals are provided so you can synchronize to other instruments in your test system In addition a TTL output indi
6. C 18 C 28 C 55 C DC voltage 100 0000 mV 0 0030 0 0030 0 0040 0 0035 0 0050 0 0035 0 0005 0 0005 1 000000 V 0 0020 0 0006 0 0030 0 0007 0 0040 0 0007 0 0005 0 0001 10 00000 V 0 0015 0 0004 0 0020 0 0005 0 0035 0 0005 0 0005 0 0001 100 0000 V 0 0020 0 0006 0 0035 0 0006 0 0045 0 0006 0 0005 0 0001 1000 000 V 0 0020 0 0006 0 0035 0 0010 0 0045 0 0010 0 0005 0 0001 True rms 100 0000 mV 3 Hz 5 Hz 1 00 0 03 1 00 0 04 1 00 0 04 0 100 0 004 AC voltage 5 Hz 10 Hz 0 35 0 03 0 35 0 04 0 35 0 04 0 035 0 004 10 Hz 20 kHz 0 04 0 03 0 05 0 04 0 06 0 04 0 005 0 004 20 kHz 50 kHz 0 10 0 05 0 11 0 05 0 12 0 05 0 011 0 005 50 kHz 100 kHz 0 55 0 08 0 60 0 08 0 60 0 08 0 060 0 008 100 kHz 300 kHz 4 00 0 50 4 00 0 50 4 00 0 50 0 20 0 02 1 000000 V 3 Hz 5 Hz 1 00 0 02 1 00 0 03 1 00 0 03 0 100 0 003 to 750 000 V 5 Hz 10 Hz 0 35 0 02 0 35 0 03 0 35 0 03 0 035 0 003 10 Hz 20 kHz 0 04 0 02 0 05 0 03 0 06 0 03 0 005 0 003 20 kHz 50 kHz 0 10 0 04 0 11 0 05 0 12 0 04 0 011 0 005 50 kHz 100 kHz 0 55 0 08 0 60 0 08 0 60 0 08 0 060 0 008 100 kHz 300 kHz 4 00 0 50 4 00 0 50 4 00 0 50 0 20 0 02 Resistance 100 0000 Q 1 mA Current Source 0 0030 0 0030 0 008 0 004 0 010 0 004 0 0006 0 0005 1 000000 kO 1 mA 0 0020 0 0005 0 008 0 001 0 010 0 001 0 0006 0 0001 10 00000 kO 100 pA
7. Test Equipment Solutions Datasheet Test Equipment Solutions Ltd specialise in the second user sale rental and distribution of quality test amp measurement T amp M equipment We stock all major equipment types such as spectrum analyzers signal generators oscilloscopes power meters logic analysers etc from all the major suppliers such as Agilent Tektronix Anritsu and Rohde amp Schwarz We are focused at the professional end of the marketplace primarily working with customers for whom high performance quality and service are key whilst realising the cost savings that second user equipment offers As such we fully test amp refurbish equipment in our in house traceable Lab Items are supplied with manuals accessories and typically a full no quibble 2 year warranty Our staff have extensive backgrounds in T amp M totalling over 150 years of combined experience which enables us to deliver industry leading service and support We endeavour to be customer focused in every way right down to the detail such as offering free delivery on sales covering the cost of warranty returns BOTH ways plus supplying a loan unit if available and supplying a free business tool withevery order As well as the headline benefit of cost saving second user offers shorter lead times higher reliability and multivendor solutions Rental of course is ideal for shorter term needs and offers fast delivery flexibility try before you buy zero capital expendi
8. cates Pass Fail results when limit testing is used To ensure both forward and backward compatibility the 34401A includes three command languages SCPI Agilent 3478A and Fluke 8840A 42A so you don t have to rewrite your existing test software An optional rack mount kit is available Easy to Use Commonly accessed attributes such as functions ranges and resolution are selected with a single button press Advanced features are available using menu functions that let you optimize the 34401A for your applications The included Agilent IntuiLink software allows you to put your captured data to work easily using PC applications such as Microsoft Excel or Word to analyze interpret display print and document the data you get from the 34401A You can speci fy the meter setup and take a single reading or log data to the Excel spread sheet in specified time intervals Program mers can use ActiveX compo nents to control the DMM using SCPI commands To find out more about IntuiLink visit www agilent com find intuilink 1 Year Warranty With your 34401A you get full documentation a high quality test lead set calibration certificate with test data and a 1 year warranty all for one low price ie Agilent Technologies Accuracy Specifications of reading of range Function Range Frequency 24 Hour2 90 Day 1 Year Temperature Coefficient etc 23 G EJL 237G E 23 G5 C 0
9. e Operating Environment Full accuracy for 0 C to 55 C Full accuracy to 80 R H at 40 C Storage Temperature 40 C to 70 C Weight 3 6 kg 8 0 Ibs Safety Designed to CSA UL 1244 IEC 348 RFI and ESD MIL 461C FTZ 1046 FCC Vibration amp Shock MIL T 28800E Type Ill Class 5 sine only Warranty 1 year 1 For 1 kQ unbalanced in LO lead 500 V peak maximum 2 For power line frequency 0 1 3 For power line frequency 0 1 use 40 dB or 3 use 30 dB 4 Reading speeds for 60 Hz and 50 Hz operation 5 Maximum useful limit with default settling delays defeated 6 Speeds are for 4 digits delay 0 auto zero and display OFF Ordering Information Agilent 34401A multimeter accessories included Test lead kit with probe alliga tor and grabber attachments calibration certificate test report and power cord Also includes CD with IntuiLink software IVI and VXI PnP drivers Quick start tuto rial user s guide command quick refer ence service guide and data sheet Options 34401A A6J ANSI Z540 compliant calibration Accessories Probes Leads Clip Accessories 11059A Kelvin probe set 11060A Surface mount device SMD test probes 11062A Kelvin clip set 34133A Precision electronic test leads 34134A DC coupled current probe 34136A High voltage probe 34138A Test lead set 34171B Input terminal connector sold in pairs 34172B Input calibration short sold in pairs 34330A
10. ies products applications or services please contact your local Agilent office The complete list is available at www agilent com find contactus Americas Canada 877 894 4414 Brazil 11 4197 3600 Mexico 01800 5064 800 United States 800 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 421 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries 65 375 8100 Europe amp Middle East Belgium 32 0 2 404 93 40 Denmark 45 45 80 12 15 Finland 358 0 10 855 2100 France 0825 010 700 0 125 minute Germany 49 0 7031 464 6333 lreland 1890 924 204 Israel 972 3 9288 504 544 Italy 39 02 92 60 8484 Netherlands 31 0 20 547 2111 Spain 34 91 631 3300 Sweden 0200 88 22 55 United Kingdom 44 0 118 927 6201 For other unlisted countries www agilent com find contactus Revised January 6 2012 Product specifications and descriptions in this document subject to change without notice Agilent Technologies Inc 2012 Published in USA April 24 2012 5968 0162EN Agg Agilent Technologies
11. ture lower risk and off balance sheet accounting Both second user and rental improve the key business measure of Return On Capital Employed We are based near Heathrow Airport in the UK from where we supply test equipment worldwide Our facility incorporates Sales Support Admin Logistics and our own in house Lab All products supplied by Test Equipment Solutions include No quibble parts amp labour warranty we provide transport for UK mainland addresses Free loan equipment during warranty repair if available Full electrical mechanical and safety refurbishment in our in house Lab Certificate of Conformance calibration available on request Manuals and accessories required for normal operation Free insured delivery to your UK mainland address sales Support from our team of seasoned Test amp Measurement engineers ISO9001 quality assurance Test equipment Solutions Ltd Unit 8 Elder Way Waterside Drive Langley Berkshire SL3 6EP T 44 0 1753 596000 F 44 0 1753 596001 Email info TestEquipmentHQ com Web www TestEquipmentHQ com e Measure up to 1000 volts with 6 2 digits resolution e 0 0015 basic dcV accuracy 24 hour e 0 06 basic acV accuracy 1 year e 3 Hz to 300 kHz ac bandwidth e 1000 readings s direct to GPIB Superior Performance The Agilent Technologies 34401A multimeter gives you the performance you need for fast accurate bench and system testing The 3
12. upled true rms measures the ac component of the input with up to 400 Vdc of bias on any range Crest Factor Maximum of 5 1 at full scale Additional Crest Factor errors non sinewave Crest factor 1 2 0 05 of reading Crest factor 2 3 0 15 of reading Crest factor 3 4 0 30 of reading Crest factor 4 5 0 40 of reading Input Impedance 1 MQ 2 in parallel with 100 pF Input Protection 750 Vrms all ranges Resistance Measurement Method Selectable 4 wire or 2 wire Ohms Current source referenced to LO input Maximum Lead Resistance 4 wire 10 of range per lead for 100 Q 1 kQ ranges 1 kQ per lead on all other ranges Input Protection 1000 V all ranges DC Current Shunt Resistance 5 0 for 10 mA 100 mA 0 10 for1A 3A Input Protection Externally accessible 3 A 250 V fuse Internal 7 A 250 V fuse True RMS AC Current Measurement Method Directly coupled to the fuse and shunt ac coupled true rms measurement measures the ac component only Shunt Resistance 0 1 0 for 1 A and 3 A ranges Input Protection Externally accessible 3 A 250 V fuse Internal 7 A 250 V fuse Frequency and Period Measurement Method Reciprocal counting technique Voltage Ranges Same as ac voltage function Gate Time 1 s 100 ms or 10 ms Continuity Diode Response Time 300 samples s with audible tone Continuity Threshold Selectable from 1 0 to 1000 0 Measurement Noise Rejection 60 50 Hz dc CMRR 140 dB