Home

HEAVY DUTY DEHUMIDIFIER USER MANUAL

image

Contents

1. i e This machine should be serviced by qualified Ebac personnel or other persons having technical competence servicing refrigeration equipment following the instructions in the Ebac service manual e Ebac service manuals and spares lists are available upon request by contacting your local Ebac distributor Never operate the unit in a bathroom or swimming pool area Do not use the machine if the power cord or cabinet are damaged Do not poke objects into and of the grilles on the machine Do not cover or obstruct the air inlet or outlet When running the noise level of this machine is less than 70dba This machine complies with the electromagnetic compatibility 1992 regulations This machine has been manufactured in the United Kingdom Ensure this unit is orotected bv a 15A Circuit Drawing No TPC207 Issue 2 Date 24 01 12 Your Ebac Dehumidifier is packed in a plastic wrapper please ensure that it is disposed of safely and where it will not be a danger to children INTRODUCTION Your Ebac Heavy Duty Dehumidifier is designed to help dry flooded or damp areas Ideal where natural drying is just too slow Drying with a dehumidifier enables fast drying without problems assosiated with heat drying plaster etc can crack HOW YOUR DEHUMIDIFIER WORKS Your dehumidifier draws in the moist air cooling it to a temperature where excess moisture will condense thereby removing the excess moisture This in turn
2. 1 Check that the plug is fully pushed into the markings identifying the terminals in your own plug socket and is switched on proceed as follows 2 Check with some other electrical device that The wire which is coloured Green and Yellow must the wall socket is live If it is not contact a Pe Connected to the terminal in the plug which is IF YOUR DEHUMIDIFIER FAILS TO As the colours of the wires in the mains lead of this B OPERATE appliance may not correspond with the coloured l E LTD qualified electrician marked with the letter E or by the Earth Symbol or 3 Check the fuse in the plug If you replace the coloured Green and Yellow The wire which is fuse refit with a 13Amp fuse coloured Blue must be connected to the terminal in 4 Check the humidistat control is turned te plug which is marked with the letter N or Fi EAVY DU i Y clockwise coloured Black The wire which is coloured Brown 5 Check that the faulty pump indicator light is must be connected to the terminal which is marked not illuminated on the control panel with the letter L or coloured Red Should none of the above remedies work then You must dispose of the non rewireable plug once it disconnect from the mains Contact the help line Pas been removed from the flexible cord It is on 01388 664400 DO NOT attempt to repair the dangerous to attempt to insert the plug into any unit or unscrew the outer casing electrical socket elsewhere in the house If the D fe H
3. dries anything in the immediate area which is damp The moisture is collected in the water container The air is rewarmed and passed back approximately 2 C warmer Condenser Evaporator Cooting Coil OPERATING YOUR DEHUMIDIFIER IMPORTANT OPERATING YOUR DEHUMIDIFIER The amount of moisture removed by your dehumidifier will vary according to the conditions in which it is operating For example operating in very cold temperatures will reduce water extraction levels The time taken to dry an area will depend on the size of area to be dried and level of moisture to begin with To achieve maximum benefit form your dehumidifier you should ensure a It is permanently connected to the mains and controlled via the Humidistat b It is not switched off for long periods of time due to an incorrect setting of the Humidistat or because the condensate pump is not working c Door to areas not to be dried are kept closed d External doors and windows are kept closed as much as possible CONTROLS Your dehumidifier is fitted with an adjustable humidistat and faulty condensate pump indicator SWITCHING ON YOUR DEHUMIDIFIER Before connecting it to the mains you should ensure that the humidistat is turned fully anti clockwise fig A Once connected to the mains power the humidistat control should be turned clockwise until you hear the unit operate fig B To protect the compressor you should allow 5 minutes be
4. i U M i DI Fi E R flexible cord becomes damaged it must be replaced ELECTRICAL CONNECTION RERE iiedl cord If the appliance is fitted with a plug for which your an appropriate plug fitted CHANGING THE FUSE U S E R MAN UAL socket is unsuitable then it should be cut off and l l l l l Only 13 Amp fuses that are ASTA approved to This appliance complies with the suppression BS1362 should be used requirements of the EEC direction 82 199 EEC aS The fuse cover must be refitted after replacement embodied in BS800 1988 of the fuse In the event of the fuse cover being IMPORTANT The wires in this mains lead are lost or damaged the plug must not be used until a coloured in accordance with the following code replacement is obtained Replacement fuse Green amp Yellow Earth covers which must be coloured BLACK are Blue Neutral obtainable from electrical retailers Brown Live WARNING THIS APPLIANCE MUST BE EARTHED TECHNICAL SPECIFICATIONS CD35P 230V 50Hz 1 Phase Height 550mm OO we SS Oa SSS SSS ES Depth 350mm Se Weight 26 kg SS eee lS Min Operating Temperature 1 C SES To S l S Se Max Operating Temperature 35 C SoS PSS SS ee Water Extraction 24hrs 32 C 90 RH 101 SS Max Power Consumption 32 C 90 RH 250 W SSS SSS eS i lt pa Sie d Max Running Current 2 A Sorote Oooo oeoS Fuse Rating UK 13 A SSS SS SSS SSS i SSS SSS SSS SSS OH Pump Capacitv 3 2 a SS a er e Do not remove the front or rear panels CSS P
5. lluminate NOTE after the pump has emptied there will still be a small amount of water standing in the pump reservoir which will leak if the dehumidifier is not kept upright PERMANENT DRAINAGE When your dehumidifier is to be used constantly in one area it can be fitted to drain continuously Ideal when the property is to be left unoccupied To do this fit the supplied tubing 7meters long to the quick release connection at the back of the dehumidifier and run the tubing to a suitable drain If no tube is supplied then a Suitable length of tubing with a 3 8 inside diameter should be used Once the tubing is fitted the dehumidifier will automatically empty as the pump fills NOTE the tubing should not be more than 2meters above the height of the pump as flooding within the unit may occur or the condensate pump damaged USE OF PERMANENT DRAINAGE When in use tubing should be run to a Suitable drainage point ensuring that the tube doesn t rise more than 2meters above the condensate pump outlet otherwise flooding may occur
6. tween switching the dehumidifier off and on again CY ECT Y OPERATING THE HUMIDISTAT The humidistat works in a similar way to a central heating thermostat but instead of measuring temperature it measures the amount of moisture in the air You may select the level of moisture you require Known as Relative Humidity and the unit will operate to achieve that level and then switch off As a general guide the higher the setting the lower the Relative Humidity will be before the machine switches off Therefore the machine will operate longer to achieve this If the dehumidifier switches off and drying is not complete it is possible that the humidistat setting is too low and may need increasing fig C Conversely if you no longer have condensation and the unit is still operating then the humidistat setting may need reducing fig D DEFROST OPERATION At certain temperatures the water taken freezes onto the pipes inside your dehumidifier and therefore needs to be defrosted This model features an automatic defrost which will clear any ice build up MAINTENANCE EMPTYING THE WATER CONTAINER As the condensate pump fills with water it will automatically activate and empty via the tube outlet located at the back of the dehumidifier this should be connected to a water container or permanent drain If the pump fails then the dehumidifier will automatically switch off and the warning indicator on the controls panel will i