Home

S&S ® Cycle, Inc.

image

Contents

1. amp S with a copy ofthe original invoice of purchase and a detailed letter outlining the nature of the problem how the part was used and the circumstances at the time of failure If after an evaluation has been made by S amp S and the part was found to be defective repair replacement or refund will be granted ADDITIONAL WARRANTY PROVISIONS 1 S amp S shall have no obligation in the event an S amp S part is modified by any other person or organization 2 S amp S shall have no obligation if an S amp S part becomes defective in whole or in part as a result of improper installation improper maintenance improper use abnormal operation or any other misuse or mistreatment of the S amp S part 3 S amp S shall not be liable for any consequential or incidental damages resulting from the failure of an S amp S part the breach of any warranties the failure to deliver delay in delivery delivery in non conforming condition or for any other breach of contract or duty between S amp S and a customer 4 S amp S parts are designed exclusively for use in Harley Davidson and other American v twin motorcycles S amp S shall have no warranty or liability obligation if an S amp S part is used in any other application NOTES AND PREPARATION INSTRUCTIONS ALL INSTALLATIONS 310 0623 TC3 Cam Support Plate for 1999 06 models except 2006 Dyna models must use late style pump late style hydraulic chain tensioners 310 0625 TC3 Cam Support Pla
2. high rpm operation 310 0623 1999 06 5 4 x Cam Plate Replacement Parts 6 50 8331 Ve 27 taper pipe plug 8 1065723 Hydraulic tensioner block off kit 9 500026 O ring kit 310 0625 2007 up O x N W
3. toxic when breathed Do not smoke Perform installation in a well ventilated area away from open flames or sparks If motorcycle has been running wait until engine and exhaust pipes have cooled down to avoid getting burned before performing any installation steps Before performing any installation steps disconnect battery to eliminate potential sparks and inadvertent engagement of starter while working on electrical components Read instructions thoroughly and carefully so all procedures are completely understood before performing any installation steps Contact S amp S with any questions you may have if any steps are unclear or any abnormalities occur during installation or operation of motorcycle with a S amp S part on it Consult an appropriate service manual for your motorcycle for correct disassembly and reassembly procedures for any parts that need to be removed to facilitate installation Use good judgment when performing installation and operating motorcycle Good judgment begins with a clear head Don t let alcohol drugs or fatigue impair your judgment Start installation when you are fresh Be sure all federal state and local laws are obeyed with the installation For optimum performance and safety and to minimize potential damage to carb or other components use all mounting hardware that is provided and follow all installation instructions Motorcycle exhaust fumes are toxic and poisonous and must not be breathed Run motorcycle in
4. H D 42325 Camshaft Needle Bearing Remover Installer H D 43644 Camshaft Remover Installer H D 42314 Crankshaft Camshaft Sprocket Locking Tool Some early 1999 model engines do not have a chain oiler boss See Pictures 3 and 4 If Your engine does not have this boss screw 500 0346 must be installed to block the oil hole in the back side of the cam plate Install with red thread locker and tighten to 70 in lb See Figure 1 Picture 3 Figure 1 ITV GS 1 X P Cto s y tL Ager e 1999 models used interchangeable ball bearings on the outer end of both cams For 2000 and up the rear bearing is a roller type and the front bearing is a ball bearing type It is highly recommended to update 1999 models to the 2000 and up bearing set pictured in Picture 5 These bearings are included in the S amp S cam installation kits for chain drive cams RFPS EE IT p ge lt gt RS METER c SE te Picture 5 Y Installation steps for all cam plates Inspect plate to verify that it is the correct part number for your application Refer to assembly drawings on last two pages Find drawing for the plate that you have Check to make sure all parts listed have been included Call S amp S if any parts are missing Check to make sure all plugs have been installed Wash cam plate with clean parts cleaning solvent Before starting any work on motorcycle disconnect negative terminal of battery to eliminate potential
5. Instruction 510 0354 05 18 15 Rev 2 Copyright O 2015 by S amp S Cycle Inc All rights reserved Printed in the U S A SES Cycle Jac 14025 Cty Hwy G PO Box 215 Viola Wisconsin 54664 Phone 608 627 1497 Fax 608 627 1488 Technical Service Phone 608 627 TECH 8324 Technical Service Email sstech sscycle com Website www sscycle com Installation Instructions TC3 Cam Support Plates for 1999 up Harley Davidson Big Twins DISCLAIMER These parts are designed as service repair components for the maintenance of Harley Davidson motorcycle engines They are intended to provide the same fit and function as the stock components that they replace It is the sole and exclusive responsibility of the user to determine the suitability of the product for his or her use and the user shall assume all legal personal injury risk and liability and all other obligations duties and risks associated therewith The words Harley Harley Davidson H D Sportster Evolution and all H D part numbers and model designations are used in reference only S amp S Cycle is not associated with Harley Davidson Inc SAFE INSTALLATION AND OPERATION RULES Before installing your new S amp S part it is your responsibility to read and follow the installation and maintenance procedures in these instructions ana follow the basic rules below for your personal safety Gasolineis extremely flammable and explosive under certain conditions and
6. a well ventilated area where fumes can dissipate IMPORTANT NOTICE Statements in this instruction sheet preceded by the following words are of special significance WARNING Means there is the possibility of injury to yourself or others CAUTION Means there is the possibility of damage to the part or motorcycle NOTE Other information of particular importance has been placed in italic type S amp S recommends you take special notice of these items WARRANT Y All S amp S parts are guaranteed to the original purchaser to be free of manufacturing defects in materials and workmanship for a period of twelve 12 months from the date of purchase Merchandise that fails to conform to these conditions will be repaired or replaced at S amp S option if the parts are returned to us by the purchaser within the 12 month warranty period or within 10 days thereafter In the event warranty service is required the original purchaser must call or write S amp S immediately with the problem Some problems can be rectified by a telephone call and need no further course of action A part that is suspect of being defective must not be replaced by a Dealer without prior authorization from S amp S If it is deemed necessary for S amp S to make an evaluation to determine whether the part was defective a return authorization number must be obtained from S amp S The parts must be packaged properly so as to not cause further damage and be returned prepaid to S
7. oil properly to and from your motor Inspect inner cam bearings now is the time to replace these bearings while the engine is apart Refer to manual for proper procedure and proper tools to use when replacing these bearings Install cam plate oil pump and cams per the factory manual or instructions provided by manufacturer of aftermarket cams or oil pump S amp S recommends that all mounting hardware on cam support plate and oil pump be tightened to 100 in Ib using the torque sequences shown in Figure 2 Cam support plate fasteners are shown in circles Oil pump fasteners are shown in squares Th 11 Pressure relief valve on S amp S cam plate has been set at the factory to relieve at approximately 40 psi Using a caliper note the distance from the end of the pressure relief screw to the pressure relief nut and note this dimension for future reference See Figure 3 12 The pressure relief valve is designed to keep the pump from building excessive oil pressure at high RPM s Resist the temptation to turn the screw in to try and raise the low rpm oil pressure If your engine has no oil pressure at idle turning the pressure relief screw in more will normally not help this condition as this pressure will be below the operating point of the pressure relief valve If you do adjust the pressure relief valve to something other than the factory setting We recommend not turning it more than t
8. sparks and inadvertent engagement of starter while working on motorcycle Clean and flush your oil tank pan and oil lines to prevent foreign material from being sucked through your oil pump and through your new cam support plate The oil filter should also be changed NOTE It is very difficult to remove all of the debris from oil pans with the swaged on baffle plate without removing the plate If you have a pan with a swaged on baffle plate and have had a large amount of debris go through the motor it is advisable to remove this plate clean the pan and then drill and tap the pan to accept screws to reinstall the plate 6 10 Refer to proper H D manual for the model of bike you will be working on for the proper removal of all components Save the original fasteners to be reused when S amp S cam support plate is installed Once you have properly removed the cam support plate and oil pump from the motor per HD manual inspect flywheel for pinion shaft run out Refer to manual for proper inspection procedure S amp S recommends no more than 003 total indicated run out on pinion shaft while checked in the cases If you intend to reuse your existing oil pump it must be inspected to ensure that it is serviceable Refer to manufacturer service wear limits for the gears and pump body bores If the areas under the pump gears are scored kidney shaped ports separator plate this will adversely affect the pumps ability to supply and or return
9. te for 2007 up and 06 Dyna models with bushing style cams NOTES S amp S does not manufacture a Cam Support Plate for use with early 1999 2006 oil pumps or spring loaded chain tensioners as we feel these are inferior to the later style components and are best not used e Possible failure may result if thread locking compound is not applied to the cam drive sprocket flange bolts Always prepare threads according to the instructions on the container e All reference to Harley Davidson part numbers is for identification purposes only We in no way are implying that any of S amp S Cycle s products are original equipment parts or that they are equivalent to the corresponding Harley Davidson part numbers Installation of S amp S cam support plate requires the use of special tools and repair manuals for the model bike you will be doing the work on Attempting the installation without the proper tools and manuals will be difficult Damage can result which will not be covered under warranty See Pictures 1 and 2 Picture 1 Special tools required for 2007 later models 1 Camshaft Needle Bearing Remover Installer HD Part Number 42325 2 Crankshaft Camshaft Sprocket Locking Tool HD Part Number 47941 for late roller style chains Picture 2 Special tools required for 1999 06 models H D 442313 Cam Chain Tensioner Unloader for removing cam chains from 1999 2006 bikes with spring loaded cam chain tensioners
10. urn at a time One half turn of the screw will move the adjuster 025 which typically changes oil pressure approximately 4 psi but other factors may effect the actual change in pressure I SZ A cw L eS NJF I EB O wy C 4 ai Wu H C d 7 NOTES e Turning the pressure adjusting screw in more than necessary will cause high oil pressure at high RPM s but will also needlessly raise oil temperature and rob horsepower without really raising low rpm oil pressure Ideally you want to keep your oil pressure as low as you can while keeping the tappets quiet If installing cam plate with the motor in the bike put transmission in high gear and raise rear wheel off the table so you can turn the engine over using rear wheel e S amp S does not supply hydraulic cam chain tensioners with new cam plates You will either need to reuse your stock tensioners or purchase new ones They are available from S amp S Cycle s Viola V twin service parts catalog Part numbers 330 0283 and 330 0384 for primary and secondary tensioners e Hydraulic tensioner block off kit is included for use with gear drive cams Follow gear drive cam instructions for installation S amp S recommends replacing stock spring style hose clamps on oil cooler lines where they attach to the filter adaptor with crimp style clamps Spring clamps do not provide adequate clamping force to keep oil lines secure on the hose nipples under extended

Download Pdf Manuals

image

Related Search

Related Contents

article as  Acronis Disk Director Server 10.0, AAS>AAP, ALP, 50-499u, Upg, FR  System Profiles - Renesas Electronics    Nano Manual - Air Sailing, Inc  Fantom Vacuum PT301H User's Manual  Vision Pro  セキュリティドアホン解錠ボタン付き副親機 HTUーSL  PRO TSX 101 Projektierung für  LA MESURE DIRECTE DES DISTANCES  

Copyright © All rights reserved.
Failed to retrieve file