Home

Pro Line Gas Cooktop With TripleTier Crown Burner

image

Contents

1. 40 KitchenAid TECHNICAL EDUCATION Pro Line Gas Cooktop With TripleTier Crown Burner Models KGCV465MSS amp KGCV465MMT JOB AID 4317358 FORWARD This KitchenAid Job Aid Pro Line Gas Cooktop With TripleTier Crown Burner Part No 4317358 provides the technician with information on the installation operation and service of the Pro Line Gas Cooktop It is to be used as a training Job Aid and Service Manual For specific information on the model being serviced refer to the Use and Care Guide or Wiring Diagram provided with the cooktop The Wiring Diagram used in this Job Aid is typical and should be used for training purposes only Always use the Wiring Diagram supplied with the product when servicing the unit GOALS AND OBJECTIVES The goal of this Job Aid is to provide detailed information that will enable the service technician to properly diagnose malfunctions and repair the Pro Line Gas Cooktop The objectives of this Job Aid are to e Understand and follow proper safety precautions Successfully troubleshoot and diagnose malfunctions Successfully perform necessary repairs Successfully return the cooktop to its proper operational status WHIRLPOOL CORPORATION assumes no responsibility for any repairs made on our products by anyone other than Authorized Service Technicians Copyright 2004 Whirlpool Corporation Benton Harbor MI 49022 TABLE OF CONTENTS
2. b Remove the three T 20 torx burner base screws Rear Gas Line le jern he E n N 7 i e A kai NM VE iang k ih 4 s D b YA Burner Base Screw 1 of 3 c Lift the burner base from its bracket as 5 remove the ignitor from the far as the bottom gas line will allow and TripleTier Crown burner base then remove the gas line a Remove the burner base from the mum bracket see step 4 b Slide the clip off the ignitor and remove the ignitor from the base Bottom Gas Line c Remove the control and front panels from the unit see pages 4 6 and 4 7 for the procedures d Disconnectthe orange ignitor wire from the spark module terminal Orange Wire Connector Spark Module AWARNING 1 Turn off gas supply and disconnect power to the cooktop 2 Remove the knobs from the gas valve stems REMOVING STANDARD GAS VALVE AND THE IGNITION SWITCH ASSEMBLY 4 Toremove a standard gas valve a Remove the rubber shield from the Electrical Shock Hazard standard gas valve you are servicing Standard Valve Rubber Shield 1 of 4 Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or electrical shock Fire Hazard Shut off gas supply line valve before servicing Check all gas line connections and replace all par
3. 2 b Remove the three T 20 torx screws from the burner cover and remove the cover Burner Cover Screw 1 of 3 c Remove the two T 20 torx screws from the orifice cover and remove the cover Orifice Cover Fv 2 Screws BE X d Use a 7 mm nut driver and remove the two burner orifices AER External Burner Orifice Internal Burner Orifice 8 Install the L P orifices in the burners see the charts for the proper locations Parts provided with conversion kit L P Orifice Package 8285442 Conversion Instructions 8285441 Conversion Label 8285453 L P Orifice Package for TripleTier Crown Burner 8285443 Standard Burners 4 Rating Color Size Burner 5 000 B T U Red 070mm small 12 000 B T U Blue 1 10 mm Large TripleTier Crown Burner Rating Color Size Burner 11 800 B T U Internal Replace the burner caps and grates To set the low flame size for the stan dard burners a Remove the control knob from the gas valve b Turn on the power and gas and set the flame to the LO setting Insert a flat blade screwdriver into the hollow stem of the gas valve and en gage it with the slot in the adjustment screw Turn the screw until the flame size is as small as possible without going out NA A 3 lt SALA V a EEG AA x CN A N 4 20 Be pri 2 at yy PEU Ser ae BE UV 4 Lx VR Wa
4. a KitchenAid designated service company SECOND THROUGH FIFTH YEAR LIMITED WARRANTY ON ELECTRIC ELEMENTS CERAMIC GLASS COOKTOP GAS BURNERS AND SOLID STATE TOUCH CONTROL SYSTEM On electric ranges and electric cooktops in the second through fifth years from the date of purchase when this appliance is operated and maintained according to instructions attached to or furnished with the product KitchenAid will pay for factory specified parts for any electric element to correct defects in materials or workman ship On ceramic glass ranges and ceramic glass cooktops in the second through fifth years from the date of pur chase when this appliance is operated and maintained according to instructions attached to or furnished with the product KitchenAid will pay for factory specified parts for the ceramic glass cooktop KitchenAid warrants that the ceramic glass cooktop will not discolor the cooktop pattern will not wear off the rubber seal between the ceramic glass cooktop and porcelain edge will not crack the ceramic glass cooktop will not crack due to thermal shock and the surface unit elements will not burn out On gas ranges and gas cooktops in the second through fifth years from the date of purchase when this appli ance is operated and maintained according to instructions attached to or furnished with the product KitchenAid will pay for factory specified parts for any gas burner to correct defects in materials or workmanship On ranges
5. er anh UM STI RUNE T C s E ART SRG an Je 00 y IS e Standard Burner Flame LO Adjustment d Quickly turn the gas valve from LO to HI and then back to LO The flame should be on steady and not go out 11 To set the TripleTier Crown Burner a Remove the control knobs from the five gas valves b Remove the control panel from the front panel see page 4 6 Pull the rubber shield off the gas valve stem d Turn on the power and gas and set the inner and outer burner flames to the LO setting e One at a time insert a flat blade screw driver into the slot in the external and internal adjustment screws Turn each of the screws until the flame sizes are as small as possible without going out 3 TripleTier Burner Internal Flame LO d Adjustment TripleTier Burner External Flame LO Adjustment f Quickly turn the gas valve from LO to HI and then back to LO Both flames should be on steady and not go out NOTES 2 4 THEORY OF OPERATION TripleTier CROWN BURNER The burner valve for the new 18 000 BTU TripleTier Crown burner has two gas outlets and two burner orifices The center burner operates as a 600 BTU sim mer burner and an 18 000 BTU full burner The simmer burner operates when the valve burner stem is turned to that position of its rotation see the following page A valve mounted ig nition switch provides burner ignition from the
6. single 6 slot spark module which is mounted on the left side behind the front panel TripleTier Valve W Ignition Switch n 4 E A e 4 u a l n Ignition Switch TripleTier CROWN BURNER VALVE OPERATION VALVE OPERATION LIGHT 42 STOP LIGHT 75 INNER BURNER 90 OFF POSITION 19 FULL RATE INNER BURNER 130 LOW RATE Inner Crown Ignition 42 to 75 Degrees 230 TRIPLE FLAMES LOW RATE 180 TRIPLE FLAMES FULL RATE Outer Crown Ignition Angle gt 130 Degrees Inner Crown Maximum 90 Degrees All Crowns Maximum 180 Degrees Inner Crown Minimum Detention 130 Degrees All Crowns Minimum 230 Degrees TripleTier CROWN BURNER CONSTRUCTION The exploded view of the Crown mounted in the top of the burner base while burner shows how the burner is disassembled the other orifice is concealed by a cover Tech The burner uses two orifices that are located nicians should be aware of the second orifice in the burner base One of the orifices is when performing any service or gas sion Burner Caps 3 Burner Ring gt Burner Base gt Cover TripleTier Crown Burner Assembly NOTES 3 4 COMPONENT ACCESS This section instructs you on how to service each component inside the KitchenAid Pro Line Gas Cooktop With TripleTier Crown Burner The cooktop c
7. unit Remove Power A Cord Strain Relief Ground Wire Screw P Black VWire Connector Black Wire TESTING Before testing any of the components perform the following checks The most common cause for control failure is corrosion on connectors Therefore discon necting and reconnecting wires will be nec essary throughout test procedures All tests checks should be made with VOM or DVM having a sensitivity of 20 000 ohms per volt DG or greater e Check all connections before replacing com ponents looking for broken or loose wires failed terminals or wires not pressed into connectors far enough Resistance checks must be made with power cord unplugged from outlet and with wiring harness or connectors disconnected 4WARNING Electrical Shock Hazard Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or electrical shock IGNITION SWITCHES Refer to pages 4 6 and 4 8 for the procedure for servicing the ignition switches NOTE The four standard ignition switches will be serviced as a complete assembly If a switch is defective the complete assembly must be replaced The TripleTier Crown burner igni tion switch is serviced separately 1 Turn off gas supply and disconnect power to the cooktop 2 Setthe ohmmeter to the R x 1 scale Standard Burner Ignition Switch TripleTier Crown Burner Ig
8. Lid iv REMOVING THE SPARK MODULE amp POWER GORD A WARNING Electrical Shock Hazard Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or electrical shock Fire Hazard Shut off gas supply line valve before servicing Check all gas line connections and replace all parts and panels before operating Failure to do so can result in explosion fire or other injury 1 Turn off gas supply and disconnect power to the cooktop 2 Remove the control and front panels from the unit see pages 4 6 and 4 7 for the procedures Power Cord Spark Module 3 Toremove the spark module a Disconnect the wire connectors from the spark module terminals see the wiring photo at the top of the right column b Remove the two hex head screws from the spark module and remove it from the unit TEL iA Screw 10 of 2 Es 4 10 gt TAY Spark Sm ML AR W a m mi Light Brown Brown Orange Dark White Brown Green Yellow To remove the power cord a Cut or loosen the wire tie and discon nect the black power cord wire from the spark module terminal b Disconnect the other black power cord wire from the harness connector c Remove the screw and disconnect the green ground wire from the chassis d Remove the strain relief from the chas sis and remove the power cord from the
9. ND SERVICE POINTERS www servicematters com IN CANADA FOR PRODUCT SPECIFICATIONS AND WARRANTY INFORMATION CALL 1 800 461 5681 FOR TECHNICAL ASSISTANCE WHILE AT THE CUSTOMER S HOME CALL THE TECHNICAL ASSISTANCE LINE 1 800 488 4791 HAVE YOUR STORE NUMBER READY TO IDENTIFY YOU AS AN AUTHORIZED SERVICER KitchenAid FOR THE WAY IT S MADE
10. NDRAFT N INTERNATIONAL COLLECTION P COMMERCIAL S STANDARD PORCELAIN METAL T TEMPERED GLASS V VBL PRO LINE SERIES X 208 VOLTS CAPACITY SIZE SERIES CONFIGURATION 1ST POSITION 2ND POSITION 1 STANDARD 0 30 WIDE 2 GRILL GRIDDLE 2 42 OR 12 WIDE 3 TEMPERED GLASS 3 33 WIDE 4 COMMERCIAL 5 15 WIDE 5 CERAMIC GLASS 6 36 WIDE 8 MODULAR DOWNDRAFT 8 48 WIDE 0 2 BURNER ELE SYS FEATURES 0 STANDARD ELEMENTS BURNERS 1 RADIANT ELEMENTS 2 DUAL ELEMENTS 3 SEALED BURNERS WITH GRIDDLE 4 SEALED BURNERS WITH GRILL amp GRIDDLE 5 SEALED BURNERS CAST ELEMENTS OR SEALED BURNERS WITH TRIPLE TIER 6 2 5 BURNERS ELEMENTS 7 HALOGEN ELEMENTS OR 6 BURNERS 8 TOUCH CONTROLS 9 INDUCTION YEAR OF INTRODUCTION M 2003 COLOR CODE MT METEORITE SS BRUSHED STAINLESS STEEL ENGINEERING CHANGE 0 BASIC RELEASE SERIAL NUMBER SERIAL NUMBER x P 27 06472 MANUFACTURING SITE X OXFORD YEAR OF PRODUCTION P 2003 WEEK OF PRODUCTION 27th Week PRODUCT SEQUENCE NUMBER 1 1 MODEL amp SERIAL NUMBER LABEL AND WIRING DIAGRAM LOCATIONS The Model Serial Number label and Wiring Diagram locations are shown below Model amp Serial Number Label Location Bottom Of Front Panel Wiring Diagram Location Behind Front Panel SPECIFICATIONS Release Info Ultra Power Wok Burner Dimensions Specifications Exterior Dimensi
11. Page GENERAL a ii rv 1 1 KitchenAid Model amp Serial Number k 1 1 Model amp Serial Number Label And Wiring Diagram Locations 1 2 SPENN DEREN 1 3 grin ao ATEN de Tm 1 4 INSTALLATION INFORMATION 0000 ccc c cece secs sees cece eeeeeeese esse eeseeeseeeseeeeseeseeeeageees 2 1 L P Gas COMS NS 2 1 THEORY OF OPERA TION u 3 1 TAPENE COW BUNE een be b e an n coast cota Sa KA 3 1 COMPONENT ACCESS se 4 1 COMPONENT LOCATIONS sa OTT 4 1 Removing The Burners And Cooktop 4 2 Removing A Burner Base amp lgnitor occococccocccccnoconoconoconoconononnonanonanononocnnnoncnonaninanenos 4 4 Removing A Standard Gas Valve And The Ignition Switch Assembiy 4 6 Removing The Triple Tier Crown Burner Ignition Switch And Gas Valve 4 8 Removing The Spark Module 8 Power Cord ooccooccoccncccncocccoccconcocococonnnncnonononanononoconnnnnos 4 10 COMPONENT FESTING teu ee 5 1 GMN SWINGING P 5 1 WIRING DIAGRAM 252 6 1 VANDO DEN NN 6 1 NOTES GENERAL KITCHENAID MODEL amp SERIAL NUMBER DESIGNATIONS MODEL NUMBER MODEL NUMBER E GC V 46 5 SS 0 K KITCHENAID BRAND PRODUCT IDENTIFICATION EC ELECTRIC COOKTOP GC GAS COOKTOP MERCHANDISING SCHEME C CERAMIC GLASS D DOWNDRAFT VENT E ELECTRONICS G GRILL GRIDDLE M MODULAR DOW
12. and built in ovens in the second through fifth years from the date of purchase when this appliance is operated and maintained according to instructions attached to or furnished with the product KitchenAid will pay for factory specified parts for the porcelain oven cavity inner door if the part rusts through due to defects in materials or workmanship KitchenAid will pay for factory specified parts for solid state touch control system and Magnetron tube in combination ovens to correct defects in materials or workmanship SIXTH THROUGH TENTH YEAR LIMITED WARRANTY ON RANGES AND BUILT IN OVENS PORCELAIN OVEN CAVITY INNER DOOR On ranges and built in ovens only in the sixth through tenth years from date of purchase when this appliance is operated and maintained according to instructions attached to or furnished with the product KitchenAid will pay for factory specified parts for the oven cavity inner door if the part rusts through due to defects in materials or workmanship KitchenAid will not pay for 1 Service calls to correct the installation of your appliance to instruct you how to use your appliance to replace house fuses or correct house wiring or to replace owner accessible light bulbs Repairs when your appliance is used in other than normal single family household use Pickup and delivery Your appliance is designed to be repaired in the home Damage resulting from accident alteration misuse abuse fire flood improper instal
13. convert the cooktop for use with L P gas AWA R N N G perform the following steps Electrical Shock Hazard 1 Turn off gas supply to the cooktop Disconnect power before 2 Disconnect power to the cooktop servicing Replace all parts and panels before operating Failure to do so can result in Access Cap death or electrical shock Gas Distribution Valve 3 Useascrewdriver and remove the access cap on the gas distribution valve Fire Hazard Shut off gas supply line valve Make all conversions before turning gas supply valve back on Failure to follow these instructions can result in explosion fire or other injury 4 Turnthe access cap so thatthe letters L P are facing up and then reinstall the cap on NOTE Gas conversion from natural to L P the valve gas must be done by a qualified installer NAT Position L P Position Ha V Stas hee eb j 2 1 Remove the grates from the cooktop and the burner caps from the burner bases To convert the left and right front and rear burners use a 7 mm nut driver and remove the orifices NOTE Place a small piece of masking tape along the inside edge of the nut driver to help keep the orifice in the driver gt Burner Orifice a oum am TripleTier Crown Burner 7 convert the TripleTier Crown burner a Remove the four T 20 torx screws from the burner ring and remove the ring Burner Ring Screw 1 of 4 2
14. lation acts of God or use of products not approved by KitchenAid or KitchenAid Canada Repairs to parts or systems resulting from unauthorized modifications made to the appliance Replacement parts or repair labor costs for units operated outside the United States or Canada In Canada travel or transportation expenses for customers who reside in remote areas Any labor costs during the limited warranty periods A N COON KITCHENAID AND KITCHENAID CANADA SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages so this exclusion or limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state or province to province Outside the 50 United States and Canada this warranty does not apply Contact your authorized KitchenAid dealer to determine if another warranty applies If you need service first see the Troubleshooting section of the Use and Care Guide After checking Trouble shooting additional help can be found by checking the Assistance or Service section or by calling the KitchenAid Customer Interaction Center 1 800 422 1230 toll free from anywhere in the U S A In Canada contact your KitchenAid designated service company or call 1 800 807 6777 1 4 INSTALLATION INFORMATION L P GAS CONVERSION To
15. nition owitch Locate the black and white ignition switch connectors one is connected to the spark module and the other is connected to the main wire harness and disconnect them White Wire Connector Turn all of the switches to the Off position Touch the ohmmeter test leads to the connectors on the black and white switch wires The meter should indicate an open circuit infinite Separately turn each ofthe five controls to the lite position The meter should indi cate a closed circuit O ohms for each switch NOTES 5 2 WIRING DIAGRAM POWER CORD PLUG Line Neutral 1 4 Blade 5 16 Blade 120 VAC 60 Hz 1 Phase Ground 15 or 20 Ampere N J Round Pin BLK GRN or GRN YEL WHT Connect 250 Terminals BLK IGNITION SWITCHES ON VALVES Electric circuit closed when knob is rotated 55 to 95 degrees counterclockwise from OFF IGNITOR ELECTRODES NOTES 6 2 PRODUCT SPECIFICATIONS AND WARRANTY INFORMATION SOURCES IN THE UNITED STATES FOR PRODUCT SPECIFICATIONS AND WARRANTY INFORMATION CALL FOR WHIRLPOOL PRODUCTS 1 800 253 1301 FOR KITCHENAID PRODUCTS 1 800 422 1230 FOR ROPER PRODUCTS 1 800 447 6737 FOR TECHNICAL ASSISTANCE WHILE AT THE CUSTOMER S HOME CALL THE TECHNICAL ASSISTANCE LINE 1 800 253 2870 HAVE YOUR STORE NUMBER READY TO IDENTIFY YOU AS AN AUTHORIZED SERVICER FOR LITERATURE ORDERS PHONE 1 800 851 4605 FOR TECHNICAL INFORMATION A
16. omponents and their locations are shown below COMPONENT LOCATIONS TripleTier Crown Standard Burner Burner W Ignitor W lgnitor 4 Spark Module TripleTier Crown standard Burner Burner Gas Valve Gas Valve 4 amp amp Ignition Switch Ignition Switch 4 4 1 A 2 REMOVING THE BURNERS AND COOKTOP AWARNING Electrical Shock Hazard Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or electrical shock Fire Hazard Shut off gas supply line valve before servicing Check all gas line connections and replace all parts and panels before operating Failure to do so can result in explosion fire or other injury Turn off gas supply and disconnect power to the cooktop Remove the grates from the cooktop and 3 To remove a standard burner remove the two T 20 torx screws from the left and right front and rear burners and remove the burners from the cooktop see the photo at the top of the right column 4 2 2 Burner Screws Left amp Right Front amp Rear Burners TripleTier Crown Burner To remove the TripleTier Crown burner a Remove the four T 20 torx screws from the burner ring and remove the ring Burner Ring Screw 1 of 4 b Remove the three T 20 torx screws from the burner cover and remove the cover Burner Cover Screw 1 of 3 5 Remove the four phillips screws from the 6 Lif
17. ons Overall Height in 7 1 2 Not Including Grates or Backsplash Backsplash 6 1 2 Overall Width in Overall Depth in 26 7 8 Cutout Height in Measure Or Min Max 7 1 4 36 Front Console 35 1 4 Cooktop Bod 22 1 4 Cutout Back to Corner of Notch Notch Varies Cutout Width in Measure Or Min Max Cutout Depth in Measure Or Min Max Weight Net Weight 165 Shipping Weight lbs Ratings 151 171 Exterior Yes Gas Burner Configuration Gas R Front Output BTU Nat LP Gas L Front Output BTU Nat LP Gas R Rear Output BTU Nat LP Gas L Rear Output BTU Nat LP 6000 BTU 5000 BTU 6000 BTU 5000 BTU 15000 BTU 12000 BTU 15000 BTU 12000 BTU Triple Tier Flame Ultra Simmer Gas Center Output BTU Nat LP 600 BTU 600 BTU to Ultra Power 18000 BTU 14000 BTU Gas Ignition Electronic Interior Accessories Miscellaneous 8285418 LP Conversion 8285400 AGA CGA 3 1 2 Foot 3 Wire Use amp Care Guide Part Comment Agency Approvals Power Cord Length amp Wires Warrant Full Extended Gas Burners 12 Mo 2nd through 5th year parts __ a QJ KITGHENAID WARRANTY ONE YEAR FULL WARRANTY For one year from the date of purchase when this appliance is operated and maintained according to instruc tions attached to or furnished with the product KitchenAid will pay for factory specified parts and repair labor costs to correct defects in materials or workmanship Service must be provided by
18. t the cooktop off the unit front and rear corners of the cooktop Rear Screws Ld SEY C ea MEI NEM REMOVING A BURNER BASE amp IGNITOR A WARNING Electrical Shock Hazard Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or electrical shock Fire Hazard Shut off gas supply line valve before servicing Check all gas line connections and replace all parts and panels before operating Failure to do so can result in explosion fire or other injury 1 Turn off gas supply and disconnect power to the cooktop 2 Remove the cooktop from the unit see page 4 2 for the procedure 3 Toremove a standard burner base and ignitor a Use a 1 2 open end wrench and re move the gas line b Disconnect the ignitor wire from the ignitor terminal c Remove the two hex head screws from the burner base bracket and remove the burner assembly from the unit Standard Burner Base er ON Bracket Screw MU 1 of 2 Ignitor 3 Wire X Gas Line d Turnthe burner assembly upside down and remove the screw from the ignitor then remove the ignitor from the burner base e Remove the two burner base hex head screws from the bracket and remove the burner base Burner Base Screws Toremove the TripleTier Crown burner base a Use a 1 2 open end wrench and re move the rear gas line
19. ts and panels before operating Failure to do so can result in explosion fire or other injury b Pull the ignition switch off the gas valve stem and position it out of the way Pull Switch Off Valve Stem gt 32 A Standard Ignition Switches c Use a 1 2 open end wrench and re move the gas line from the valve d Remove the gas valve mounting screw and remove the valve from the gas 3 Remove the two screws from the control manifold NOTE Make sure that the panel and remove the panel from the unit rubber grommets for the valve and the screw are not cracked or damaged before you reinstall the valve Screw Screw w Grommet 4 6 5 To remove the ignition switch assem b Pullthe 4 ignition switches off the stan bly dard gas valve stems NOTE The igni a Remove the two front and three bottom tion switches must be replaced as an screws from the front panel and re ka move panel Front Screws Pull Switch Off Front Panel Valve Stem 5 c Disconnect the black ignition switch wire from the harness connector and the white wire from the spark module terminal NOTE If necessary loosen or cut the wire tie from around the black ignition switch wire Bottom Screws White Wire Connector Spark Module 4 7 REMOVING THE TripleTier CROWN BURNER IGNITION SWITCH AND GAS VALVE WARN Ne A Remove the rubber shield from the TripleTier Crown b
20. urner gas valve Electrical Shock Hazard Rubber Shield Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or electrical shock Fire Hazard Toremovethe TripleTier Crown burner Shut off gas supply line valve ignition switch before servicing a Disconnect the wire connectors from Check all gas line connections the ignition switch terminals and replace all parts and panels b Remove the two screws from the igni before operating tion switch and remove the switch from Failure to do so can result in the bracket explosion fire or other injury 1 Turn off gas supply and disconnect power to the cooktop 2 Remove the knobs from the gas valve stems WwW O 3 Remove the two screws from the control panel and remove the panel from the unit Ignition Switch amp 2 Screws Switch Wires 4 8 Toremove the TripleTier Crown burner gas valve a Use a 1 2 open end wrench and re move the two gas lines b Remove the gas valve mounting screw and remove the valve from the gas manifold NOTE Make sure that the rubber grommets for the valve and the screw are not cracked or damaged before you reinstall the valve c Remove the two ignition switch bracket screws from the gas valve and remove the bracket and ignition switch assem bly Gas Lines Switch Bracket Screw 1 of 2 A Gas Valve Screw amp Grommet y r