Home

ARMEN SKID LC SYSTEM - Essential Life Solutions

image

Contents

1. 40 02 00 02 20 02 40 03 00 03 20 03 Zo 00 00 00 20 00 40 01 00 01 20 01 40 02 00 02 20 02 40 03 00 03 20 03 40 Armen Instrument ZI de Kermelin 16 rue Amp re 56890 St Av France Phone 33 0 2 97 61 84 00 Fax 33 0 2 97 61 85 00 contact armen instrument com www armen instrument com AP HPG2 TRIX 5000 70 SKID ALOU eee TTT Te Configuration AP HPG2 binary High Pressure gradient pump 5000 ml min 70 bar max Priming valve Injection through pump unit Fraction collector 4 ways and 1 waste Back flush valve unit Recycling valve unit UV VIS with prep cell Armen Glider Prep software Computer 17 flat screen Soft installed and tested Power supply cabinet including components Flow rate range Specifications Performances Flow rate range 10 to 5 000 mL min Flow rate performance 1 accuracy with H O degassed at 20 C Repeatability better than 0 5 Gradient former Linear response from 0 5 to 99 5 System protection Pressures Min and Max adjustable Software Control via PC amp software AC mains supply voltage 220 240V 20A max 50 Hz Dimensions Width x Height x Depth in millimetres without connections Trolley 1270 x 1281 x 950 Weight 250 kg SUT E a gt ast si j anr aE ma a Linear and step gradient at 2000 mL min ss ait i LF 1 EE ba i aE id am we n
2. o The materials in contact with the liquids are Stainless steel 316L PTFE bonded with Blass fibers PTFE bonded with carbon fibers FEP KelF PVDF PEEK Kalrez Sapphire Rubies Hastelloy Zirconium Armen Instrument ZI de Kermelin 16 rue Amp re 56890 St Av France Phone 33 0 2 97 61 84 00 Fax 33 0 2 97 61 85 00 contact armen instrument com www armen instrument com
3. ARMEN SKID LC SYSTEM EETA 5 ARMEN gt INSTRUMENT d a f LO Custom solution for preparative and industrial HPLC Armen Instrument ZI de Kermelin 16 rue Amp re 56890 St Av France Phone 33 0 2 97 61 84 00 Fax 33 0 2 97 61 85 00 contact armen instrument com www armen instrument com Example of Armen Skid LC system AP HPG2 500 125 SKID p I hahaa iy vel x Configuration Binary High Pressure gradient pump 500 ml min 125 bar max Manual injector with loop Injection through pump unit Fraction collector 20 ways and 1 waste Priming valve Back flush valve unit Recycling valve unit UV VIS with prep cell RI detector Armen Glider Prep software Computer 17 flat screen Power supply cabinet including components Specifications Performances Flow rate range 1 to 500 mL min Flow rate performance 1 accuracy with H O degassed at 20 C Repeatability better than 0 5 Gradient former Linear response from 0 5 to 99 5 System protection Pressures Min and Max adjustable Software Control via PC amp software Dimensions Width x Height x Depth in millimetres without connections Trolley 1270 x 1281 x 950 Weight 250 kg Temperature 5 C to 40 C mAU mAU 4100 Linear and step gradient at 500 mL min i i i l H i i i i i i 00 00 00 00 20 00 40 01 00 01 20 01
4. a ot nn ree i EC p Linear and step gradient at 5000 mL min T LT sh Armen Instrument ZI de Kermelin 16 rue Amp re 56890 St Av France Phone 33 0 2 97 61 84 00 Fax 33 0 2 97 61 85 00 contact armen instrument com www armen instrument com Custom system on request Armen SKID LC systems could be set up according to your needs and application Large range of pumping system are available from 500 mL min to 15 L min isocratic low pressure or high pressure gradient and all kind of detectors fraction collectors and hydraulic valves could be installed All those peripherals are installing in one box and controlled through our dedicated Armen Glider Software for GMP compliance and convenient purification Design your system by indicated which peripherals you would like for a quote Pumping system AP TRIX range Isocratic or low pressure gradient mixing 500 mL min pump 250 bar Isocratic 1000 mL min pump 200 bar Isocratic 2000 mL min pump 100 bar Isocratic 3000 mL min pump 100 bar Isocratic 5000 mL min pump 100 bar Isocratic 10000 mL min pump 100 bar Isocratic 15000 mL min pump 100 bar Isocratic Quaternary gradient for AP TRIX AP HPG2 TRIX range High pressure binary gradient mixing 2 x 500 mL min pump 125 bar 2 x 1000 mL min pump 125 bar 2 x 2000 mL min pump 100 bar 2 x 3000 mL min pump 70 bar 2 x 5000 mL min pump 100 bar 2 x 6000
5. a protected database o User Login Logout Method Ran Stopped Device communication errors Times stamped records of every event RUN STOP and PAUSE Data records with all parameters every second AU flow rate gradient pressure collector position wavelength o Collection information timestamp seal number peak number volume area Three files are generated while running methods ASCII files suitable for EXCEL Software versioning Documentation User Requirements definition User manual Automated installation procedure Software engineering practices Integrated testing and debugging procedures O O O O Regulation CE Directive C E M n 89 336 CEE modified by directive n 92 31 CEE and 93 68 CEE Directive Low voltage n 73 23 CEE modified by Directive n 93 68 CEE and according to the following norms Norm CEM EN55011 amendment 1 amp 2 EN61000 4 2 amendment 1 EN61000 4 3 amendment 1 amp EN61000 4 4 Norm electrical safety EN61010 1 amendment 2 07 95 FDA GMP Good Manufacturing Practice added note o The conception of this instrument was done to avoid any retention volume in the liquid circuit o A user manual and a service manual are delivered with the instrument giving all necessary information to use the instrument to replace the seals of the pumps and check valves It s explained in detail how to clean every parts of the instrument o A practice training will be done during the IQ OQ
6. mL min pump 100 bar Hydraulic devices Manual solvent selectors Manual purge valve Recycling valve Backflush valve Column selection valve for 2 columns connection Injection unit Injection through external pump 50 mL min pump 300 bar Isocratic 100 mL min pump 250 bar Isocratic 250 mL min pump 200 bar Isocratic 500 mL min pump 100 bar Isocratic 1000 mL min pump 100 bar Isocratic 2000 mL min pump 100 bar Isocratic 3000 mL min pump 70 bar Isocratic Armen Instrument ZI de Kermelin 16 rue Amp re 56890 St Av France Phone 33 0 2 97 61 84 00 Fax 33 0 2 97 61 85 00 contact armen instrument com www armen instrument com AU OI ND LE Loop injection through manual valve Injector for AP HPG2 250 500 1000 1 mL stainless steel Loop 1 8 OD 2 mL stainless steel Loop 1 8 OD 5 mL stainless steel Loop 1 8 OD 10 mL stainless steel Loop 1 8 OD 20 mL stainless steel Loop 1 8 OD 30 mL stainless steel Loop 1 8 OD 40 mL stainless steel Loop 1 8 OD 50 mL stainless steel Loop 1 8 OD Injection through pump unit with AP HPG2 pumps Injection unit for AP HPG2 250 Injection unit for AP HPG2 500 Detection UV 06S SINGLE standard filter 254 nm other filter on request UV 06S DUAL standard filters 254 and 280 nm other filters on request UV 06S DAD 400 200 400 nm four wavelengths simultaneously scan of spectrum UV 06S DAD 600 200 600 nm four wavelengths simultaneo
7. usly scan of spectrum UV 06S DAD 800 200 800 nm four wavelengths simultaneously scan of spectrum RI Detector KNAUER 2300 Evaporative Light Scattering Detector ELSD SEDERE SEDEX Model 80LT Fraction collector Number of ways needed Armen Instrument ZI de Kermelin 16 rue Amp re 56890 St Av France Phone 33 0 2 97 61 84 00 Fax 33 0 2 97 61 85 00 contact armen instrument com www armen instrument com SU EE CN INR I General features Hardware interfaces PC to Armen instruments By RS232 Between Armen instruments Bus Can PC to UV detector By RS232 Software interfaces Controlling Armen Glider Prep software AGP CRE supervision screen allows following and controlling all operating M lc MT parameters EEE a T Pump flow rate pressure high and low pressure safety He NRA Sample volume or injection time HE Gradient former and all switching valves HOSUR et Be Detectors and data acquisition Fractions collector drove by time level and derivate peak detection Level of the solvent fractions and waste reservoirs Methods and data acquisitions are saved Recordio CFR 21 part 11 compliant Armen Glider Prep list ST Access control Software access is limited to authorized only persons through a login password mechanism Access to each screen is restricted following the user profile scheme Each event below is recorded times tamped in

Download Pdf Manuals

image

Related Search

Related Contents

NOTICE D`UTILISATION EPI  PDF版カタログをダウンロード  Télécharger - Fédération Française de Voile  Manual de Instrucciones  D2B divice address initialization by use of default address  Super-Vee Operating Instructions  Sensor Tuner  Visualizza - Industry Support Siemens  PDS-375 TR User`s Manual  Gas-Gebläsebrenner Forced draught gas burner Quemador de gas  