Home

D3 User Manual with MVP

image

Contents

1. Site Power Available dotworkz 24 VAC VDC Step Down Transformer Voltaae Matrix for Input Output High Voltage to 24 VAC P S Input Voltage To Power D2 4 mumovwc ET 7 awae r av pex 71 7 utput Voltage to Power Camera O MVP provides step down voltage to supply camera power for 12VDC and 24V Cameras 24V Camera Supply 24V output depends on Site Power Input for either 24V Direct Current or Alternating Current see table above Power Chassis integrated into D Series MVP Optional 24VAC Transformer Module available for 24VAC only cameras to convert 110 220 VAC to 24 VAC sold separately 5 dotworkzA Input Power Configuration for 24 VAC VDC 4 2 N Site Power Available Inside all D3 MVP is a Chassis similar to shown 110 220 VAC Power Source Step Down Transformer dotworkz A Single Phase Only High Voltage to 24 VAC a af Se zi The MVP comes ready for 110 220VAC Input power du Uriel Ds For 24 VAC VDC inputs Installer must take a moment to allow input configuration for Low Voltage Input Use Blue 24 VAC Bypass Cable To hook up Power inside D3 as shown below Unplug Green Plug on Chassis Then insert similar Plug Locate 24V Bypass Cable gate Green Plug on Chassis from panel mount socket then on 24V Bypass Cable Hardware Pack Provided push aside Tighten screws on plug to secure 24 VDC Color Code Red Pos
2. diameter ready for standard 7 I D NPT connector or PG13 fittings However we realize our customers are retrofitting these connectors with electrical conduit fittings We acknowledge this industry customization and installation practice and would like to guide customers to properly install these products Conduit Guidelines 1 If wires cabling or conduit are coming at enclosure wire entry level or above always create a drip loop 2 Please use only approved watertight electrical conduit and connectors IP66 or better with proper seals and fittings installed amp fully seal 3 Then after all wire and cables are installed into enclosure Seal wire entry ports inside of enclosure with any number of commercially available sealing putty s Silicone Sealant or similar products that are approved by applicable local and relevant electrical codes Dotworkz supplies two 7 diameter foam conduit plugs that when installed will assist in sealing off airflow in conduit feed thru at cable entry inside of enclosure Putty or Sealant can be used in conjunction with these plugs to assure a full seal inside enclosure cable feed entry FORCES AT WORK IN ANY UNSEALED CONDUIT WIRE FEED ENCLOSURE SYSTEM WARM MOIST IN UNSEALED CONDUIT MOVES THRU CONDUIT EXPANDING HEATED AIR IS PUSHED INTO ENCLOSURE THEN COOLS amp FEEDS EXPAND amp CONTRACT WHEN CONDUIT HEATS amp COOLS CONDENSES HUMID AIR CONDENSES ON SURFACES INSIDE WITH OUTSIDE T
3. 264 VAC 127 370 VDC Frequency Range 47 63 HZ Input Current Full Load Typ 1 8A 115VAC 1 0A 230VAC Recommended Min Circuit Breaker 6 A type C Int Electrical Working Temp 20 70C per 353 6Khrs min MIL HDBK 217F 25C m Available to Camera amp Accessories max D MVP using 110 220 VAC input to S Type enclosure Using ONE Output Using BOTH Output Channels 12VDC amp 24VDC Model 12 VDC Output OR 24 VDC Heater Blower 25 watts or 25 watts 25 watts first channel 5 watts on second Channel Tornado 25 watts or 50 watts 25 watts first channel 25 watts on second channel Ring of Fire 25 watts or 25 watts 25 watts first channel 5 watts on second channel ie v dotworkz amp Camera Power Output Power for MVP 12VDC 24VDC Two Voltage Options are available From the easy access screw terminal blocks The MVP comes prewired with a 12VDC power cable ready to plug in to some of the most common camera models However if the vour camera has a different power need the MVP can easilv adapt to most camera power needs All D2 environmental enclosures come standard with a 12VDC Right Angle Barrel Plug 3 3mm x 5 5mm with a 1mm center pin for majority of the IP cameras on the market 1 0mm F ae Center Pin 4 0mm 3 3mm i 3 3mm Center Pin Right Angle Standard Inline version If you IP camera s power connector is different but still accepts up to 13VDC for power please see our sec
4. AKDT 1007 V5 Lo I iE OTE in order io get a bracket height of 3 3 8 the Adjustment bracket must be Eet to an INVERTED height of 3 50 then the 0 125in standofi used to subtract 1 8 from it UA CB Installation Example Bracket Heights in 1 4 increment NOTE for 1 8 offsets see next page dotworkz amp systems UA CB Installation into D3 Lower Housing TEM NO PART NUMBER qm A SLD2 2 CB 1007 V5 8 32xC A H UA FXDI 2 0 375in standoff D3 Lower V2 Bracket Heights 25 3 37 5 Bracket Height measured from top Of fixed bracket to bottom of adjustment bracket UA CB Installation into D3 Lower Housing Bracket Heights 3 5 6 5 ITEMNO PART NUMBER tO 32XU f A 2 UA SLD2 3 WARGO N Bracket Height measured from top surfaces dotworkz amp COOLDOME Input Power Configuration D3 CD 12VDC Turn Off Power or leave power disconnected during Installation of All Wiring Follow all local and relevant electrical codes amp standards Test all Wiring and confirm correct voltages before wiring up amp powering up COOLDOME 4 N Site Power Available Provided P S SP500 Must be Housed Indoors or in a NEMA Electrical Enclosure 4 gt Re 110 220 VAC Power Source Single Phase Only LOW VOLTAGE RUN 12 VDC Cable to COOLDOME 500 watt Step Down P S High Voltage to 12 VDC A Wiring from
5. EMPERATURES ENCLOSURE Humid Air 6 Condensing to Water t SHOCK HAZARD Failure to fully seal enclosure wire and cabling entry ports may lead to shock hazard unsatisfactory product performance a possibility of damage to electronics in the Dotworkz enclosure product including camera damage and damage to integrated electronics due to air driven moisture traveling thru the conduit condensing and collecting in the enclosure creating a short circuit hazard Electrical Putty amp Putty Tapes Silicone Sealants Foam Sealants use very sparingly Dotworkz does not endorse nor has it evaluated any of these products Test products first and follow all manufacturers instructions Follow all applicable electrical and building codes and installation guidelines End user assumes liability for applicability of these products and their effectiveness and incurred liability in using these products 2 dotworkz amp systems gt Conduit Feeds Must Be Sealed and Satisfactory Product nce A IMPORTANT AN Foam Conduit Feed Pugs far LD Conduit Fittings Conduit Stopper Plugs prevent Humid Air exchange from venting thru external conduit into Dotworkz sealed enclosure when conduit is used with Dotworkz enclosures Vent Stopper Plugs eliminate Conduit driven condensation in surveillance camera enclosures or other outdoor enclosure products QUICK INSTALLATION GUIDE Pus plug nto c
6. FORM COMMERCIAL CODE AND OR IN ANY OTHER COMPARABLE STATE STATUTE DOTWORKZ SYSTEMS HEREBY DISCLAIMS ANY REPRESENTATIONS OR WARRANTY THAT THE PRODUCT IS COMPATIBLE WITH ANY COMBINATION OF NON V1DEOLARM PRODUCTS OR NON DOTWORKZ SYSTEMS RECOMMENDED PRODUCTS THAT THE PURCHASER CHOOSES TO CONNECT TO THE PRODUCT LIMITATION OF LIABILITY THE LIABILITY OF DOTWORKZ SYSTEMS IF ANY AND PURCHASER S SOLE AND EXCLUSIVE REMEDY FOR DAMAGES FOR ANY CLAIM OF ANY KIND WHATSOEVER REGARDLESS OF THE LEGAL THEORY AND WHETHER ARISING IN TORT DP CONTRACT SHALL NOT BE GREATER THAN THE ACTUAL PURCHASE PRICE OF THE PRODUCT WITH RESPECT TO WHICH SUCH CLAIM IS MADE IN NO EVENT SHALL DOTWORKZ SYSTEMS BE LIABLE TO PURCHASER FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND INCLUDING BUT NOT LIMITED TO COMPENSATION REIMBURSEMENT OR DAMAGES ON ACCOUNT OF THE LOSS OF PRESENT OR PROSPECTIVE PROFITS OR FOR ANY OTHER REASON WHATSOEVER dotworkz amp PRODUCT INSTALLATION PRECAUTIONS WARNINGS ADDITIONAL INFORMATION RETAIN THIS DOCUMENT IMPORTANT SAFEGUARDS 1 Read Instructions All the safety and operating instructions should be read CAUTION TO REDUCE THE RISK OF ELECTRICAL SHOCK DO NOT EXPOSE Sc uc ies COMPONENTS TO WATER OR MOISTURE 2 Retain Instructions The safety and operating instructions should be retained for The lightning flash with an arrowhead future reference 3 Heed Warnings All warnings on the unit and in the operatin
7. RKZ INC PRODUCTS DOTWORKZ SYSTEMS INC Warrants this Product to be free from defects in material or workmanship as follows PRODUCT CATEGORY PARTS LABOR All Enclosures and Electronics One 1 Year One 1 Year Power Supplies One 1 Year One 1 Year Accessory Brackets One 1 Year One 1 Year During the warranty period to repair the Product the Purchaser will deliver it to Dotworkz Systems Inc San Diego CA or return the defective product freight prepaid The Product to be repaired is to be returned in either its original carton or a similar package presenting an equal degree of protection with a Return Materials Authorization number displayed on the outer box or packing slip To obtain RMA H you must contact our Technical Support Team at 866 575 4689 Dotworkz Systems will return the repaired Product freight paid Dotworkz Systems is not obligated to provide Purchaser with a substitute unit during the warranty period or at any time After the applicable warranty period Purchaser must pay all labor and or parts and shipping charges The limited warranty stated in these product instructions is subject to all of the following terms and conditions 1 NOTIFICATION OF CLAIMS WARRANTY SERVICE If Purchaser believes that the Product is defective in material or workmanship then a written notice with an explanation of the claim shall be given promptly by Purchaser to Dotworkz Systems but all claims for warranty service must be made within the warra
8. Step Down P S to D3 CD Front of Power Supply with terminal strip The D3 CD has two Coolers that run independently To reduce low voltage current load it is best to run two pairs individually So each 12VDC paired wiring runs load of one cooler Round Water rated cable bundle such as SJOOW 4 conductor makes for an easy install and seal into provided cable ports EE EEE 2 a 4 l E High Voltage A C Input Single Phase USA Wiring Color Code Low Voltage 12 VDC Output Terminals Color oymbol Terminal Description Color Symbol Terminals Description Black L 1 Line Conductor AKA Live Hot Hed V 9 10 11 Positive VDC White N 2 Neutral Conductor Black V 12 13 14 Negative VDC Green FG 3 FG Field Ground Chassis Ground X PES P LOW VOLTAGE RUN Wire Gauge Chart for D3 CD 12VDC each cooler wired on independent 12VDC wire pairs 12 Volts D C Voltage Drop for Dotworkz I Cool Dome Wire guage In AWG below Humidity Control Pack Distance ft gt gt 0 098 0 196 0 294 0 392 0490 0 980 oss ost ose 0624 oren uuu 0 744 mura R BABA o o e CO Ce A ah A I HH SES th a Gauge Multiplier Vdc drop ft Voltage drop vdc distance ft o Acceptable line drop for Wire Gauge and Distance Gi Excessive line drop for Wire Gauge and Distance APEMBAPAPAPAPI CO A AA AA gg JM T 12 dotworkz amp COOLDOME Input Po
9. ational Security Industry Organization Furthermore Dotworkz Systems shall have no liability where a schedule is specified for regular replacement maintenance or cleaning of certain parts based on usage that the end user has failed to abide to such schedule attempted repair by non qualified personnel operation of the Product outside of the published environmental and electrical parameters if such Product s original identification trademark serial number markings have been defaced altered or removed Dotworkz Systems excludes from warranty coverage Products sold AS IS and or WITH ALL FAULTS and excludes used Products which have not been sold by Dotworkz Systems to the Purchaser All software and accompanying documentation furnished with or as part of the Product is furnished AS IS i e without any warranty of any kind except where expressly provided otherwise in any documentation or license agreement furnished with the Product 4 PROOF OF PURCHASE The purchaser s dated bill of sale must be retained as evidence of the date of purchase and to establish warranty eligibility DISCLAIMER OF WARRANTY EXCEPT FOR THE FOREGOING WARRANTIES DOTWORKZ SYSTEMS HEREBY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES EXPRESSED OR IMPLIE D INCLUDING BUT NOT LIMITED TO ANY AND OR ALLIMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND OR ANY WARRANTY WITH REGARD TO ANY CLAIM OF 1NFRINGEMENT THAT MAY BE PROVIDED IN SECTION 2 312 3 OF THE UNI
10. closure prior to enclosure use Double stick tape Velcro tape large zip ties or fine wire are common ways to secure the canister Secure canister above camera on top of camera bracket or where space provides Be sure not to obscure holes on canister so as to allow it to operate effectively There is a small window on the canister see white circle on image Ensure that the crystals are blue Occasionally especially in humid environments the canister may need to be serviced If so the crystals in the window turn pink when silica gel is saturated with moisture The tin canister can be reactivated by being placed in an oven at 300F for three hours or until crystals turn blue again The gel can be reactivated virtually and infinite number of times 13 dotworkzA systems D3 High Voltage Power Supply Specifications D3 COOLDOME SP 500 12 Power Supply VOLTAGE RANGE Note 5 88 264VAC 124 370VDC FREQUENCY RANGE 47 63Hz POWER FACTOR Typ PF20 95 280VAC PF 0 95 115VAC at full load EFFICIENCY Typ CTUM NNI 86 5 87 AC CURRENT Typ 7A115VAC 3 5A 230VAC INRUSH CURRENT Typ 18A 115VAC 36A 230VAC LEAKAGE CURRENT 3 5mA 240VAC OVERLOAD 105 13596 rated output power Protection type Fold back current limiting recovers automatically after fault condition is removed PROTECTION 138 16 2V 155 182V 18 21V 27 6 324V 31 36 5V 57 6 67 2V OVER VOLTAGE Protection type Hiccup mode recover
11. dotworkz amp systems PRODUCT INSTRUCTIONS D3 SERIES ENCLOSURES Available with MULTI VOLT PLATFORM dotworkz SYSTEMS Intentionally Blank Table of Contents Limited Warranty Info eoo ost Ir PC OR m FRED ted FR RR SERVIS DAN EROR ARE e Ded TUE er IR PREX NINNE RR aS QUE dV UIS ee Lev aaa Us sah Sero Etain seS 0 Product Installation Precautions Warnings and Installation Guidelines 1 Conduit Gu1delines sasanga agan EE 2 Vent Plugs Installation Guide 3 D3 Component Checklist for camera installation Camera Mount Bracket cccsssssccccccsssssscecccccssssecccccceesssccccccecasseeeccceeaesseeeccceeasseeeeeeeeeaes 4 intro t MVP POWET etr 5 24V Input MVP ues eeeeeeeeee 6 High Voltage odo ou d ua Dis ames EE 7 Camera Power Setup Standard 12VDC Connector and NON STANDARD 12VDC CONNECTOR 8 Cameralnstallation Generic u sas ss aaa v EVO NV Eva Y EV OPE OG caiovaiensucinsctuswatenskevann P UP TCUL aaa aa V VETE VEU UU FEY CVRELEK VE VATI used VENE 9 Steady Step Mounting Instructions 10 11 COOEDOME Input Configuration 4 12 13 Power Specifications High Voltage InpUts 14 D3 Exploded VIEW 5555545555 15 D3 Mounting Tenp eee NTEN TG NENGGAR Gahan ean Gon Gu Ga EN TUNG TEGEN TG GR ae 16 dotworkz amp LIMITED WARRANTY DOTWO
12. g instructions symbol within an equilateral triangle should be adhered to is intended to alert the user to the 4 Follow Instructions All operating amp user instructions should be followed presence of non insulated dangerous 5 Electrical Connections Only a qualified electrician should make electrical voltage within the product s enclosure connections that may be of sufficient magnitude to 6 Attachments Do not use attachments not recommended by the product constitute a risk of electric shock to manufacturer as they may cause hazards persons T Cable Runs All cable runs must be within permissible distance 8 Mounting This unit must be properly and securely mounted to a supporting structure capable of sustaining the weight of the unit Accordingly a Installation should be made by a qualified installer b Installation should be in compliance with local codes c Care should be exercised to select suitable hardware to install the unit taking into account both the composition of the mounting surface and the weight of the unit Be sure to periodically examine the unit and the supporting structure to make sure that the integrity of the SERVICE The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance installation If the unit ever needs repair service customer should contact Dotworkz S
13. itive Blue Negative Run 24V into D3 via weatherproof wiring ports provided Connect wires to appropriate Color Coded terminal shown here 24 VDC Connect wires to appropriate Color coded terminal shown above 24 VAC hook up has no polarity When all wiring is complete secure screws from plug to panel mount Then secure all wiring to be sure it does not interfere damage fan s or camera pan tilt operation dotworkzA Input Power Configuration for 110 220 VAC Shut off all power before and during wiring amp servicing Use Color coded terminals for High All Wiring must be done by a Qualified technician Voltage Input to hook up inside D3 Observe all local and applicable electrical codes a UN Inside all D3 MVP is a Chassis similar to shown Site Power Available d E m 110 220 VAC Power Source All Wiring Connections are to be made fully inside of D3 x Single Phase Only p C J The MVP comes ready for 110 220VAC Input power Use Single Phase Voltage Wiring Only Run 110 220 VAC into D3 via weatherproof wiring ports provided Connect wires to appropriate Color Coded terminal shown here High Voltage A C Typical Conventions single phase USA wiring UN convention Color Symbol Description Black L Line Conductor aka Hot wire White N Neutral Conductor C Green G Ground Wire Chassis Ground J inou Specifications B Input Voltage 90
14. nclosure This may lead to electrical shock failure and damage to electrical systems installed within enclosure including but not limited to damage to camera heater and blower circuitry cooling circuitry and other systems installed in unit Do not over tighten any Screws Stand Offs or other fasteners on this unit Failure to heed this warning will cause damage or failure of the D2 enclosure Besureto take extra care to Protect Lens of unit prior to and during installation and during service Suspension packaging box is a handy platform to protect lens and enclosure while installing camera and accessory electronics before installation Failure to protect lens will adversely affect product perform dotworkzZ Electrical Conduit Guidelines For optimal performance your Dotworkz Enclosure is designed to be Air amp Water Tight to eliminate any moisture dust and insect damage safety performance reliability and maintenance related issues Use of Electrical Conduit without sealing the entry ports inside wire feeds within Camera Enclosure will subject the inside of your enclosure to possibility of condensation driven moisture dust and insect contamination hazards Dotworkz has provided each enclosure with two Cable Gland Strain Relief seal ports that fully seal enclosure to an IP68 rating Waterproof and Airtight Seal To properly seal only one round cable is used in each e cable gland port Holes on enclosure are 7 8
15. nty period If after investigation Dotworkz Systems determines that the reported problem was not covered by the warranty Purchaser shall pay Dotworkz Systems for the cost of investigating the problem at its then prevailing per incident billable rate No repair or replacement of any Product or part thereof shall extend the warranty period as to the entire Product The specific warranty on the repaired part only shall be in effect for a period of ninety 90 days following the repair or replacement of that part or the remaining period of the Product parts warranty whichever is greater 2 EXCLUSIVE REMEDY ACCEPTANCE Purchaser s exclusive remedy and Dotworkz System s sole obligation is to supply or pay for all labor necessary to repair any Product found to be defective within the warranty period and to supply at no extra charge new or rebuilt replacements for defective parts 3 EXCEPTIONS TO LIMITED WARRANTY Dotworkz Systems shall have no liability or obligation to Purchaser with respect to any Product requiring service during the warranty period which is subjected to any of the following abuse improper use negligence accidents lightning damage or other acts of God i e hurricanes earthquakes modification failure of the end user to follow the directions outlined in the product instructions failure of the end user to follow the maintenance procedures written and recommended in the product instructions and service manual or recommended by the Intern
16. o adjust stable mounting system that adjusts to fit virtually every major PTZ camera on the market By utilizing the lower mounts around the lens on hinged lower of D3 virtually any PTZ or Mini Dome Camera can be mounted into the enclosure at any level By using the included 1 8 tall brass standoff set the Steady Step system can be attain half steps of 1 8 steps for a precision optimized camera height adjustment within dome lens The enclosure lens bubble has 3 5 of internal depth clearance beyond housing depth that enables the D3 to house cameras of heights from mini domes to camera heights of over 12 tall while providing plenty of room for integrated products with convenient mounting anchoring inserts in upper of housing The Upper mounts above the camera are freed up to mount accessories by utilizing the lower mounts only for all sizes of cameras dotworkz amp Steady Step Bracket Steps adjust in increments To adjust 1 8 between step settings add 1 8 brass male male hex stand off ITEM NO 6 shown in detail D below and provided in D3 hardware pack by threading on top of movable slide bracket of steady Steady Step Mounting System step bracket system then fastening camera bracket CB 1007 or AB 1007 UA CB Installation 1 8 Offset Add an 1 8 male male standoff to each comer DETAIL D e SCALE 1 2 ITEM NO PART NUMBER 1 832 Hex Nut 2 PEMS 8322Z N 3 0 375in standoff 4
17. on to recover 20 70 C Refer to output load derating curve WORKING HUMIDITY 20 90 RH non condensing ENVIRONMENT STORAGE TEMP HUMIDITY 40 85 C 10 95 RH TEMP COEFFICIENT 0 03 C 0 45 C VIBRATION 10 500Hz 2G 10min 1cycle period for 60min each along X Y Z axes SAFETY STANDARDS UL60950 1 TUV EN60950 1 UL60601 1 TUV EN60601 1 IEC60601 1 approved WITHSTAND VOLTAGE VP O P 4KVAC I P FG 1 5KVAC O P FG 1 5KVAC ISOLATION RESISTANCE P O P I P FG O P FG 100M Ohms 500VDC EMI CONDUCTION amp RADIATION Compliance to EN55011 CISPR11 EN55022 CISPR22 Class B HARMONIC CURRENT Compliance to EN61000 3 2 3 Compliance to EN61000 4 2 3 4 5 6 8 11 ENV50204 EN55024 EN60601 1 2 EN61204 3 medical level criteria A 353 6Khrs min MIL HDBK 217F 25 C OTHERS 101 6 50 8 29mm L W PACKING 0 15Kg 96pcs 15 4Kg 0 89CUFT Recommended circuit breaker 6 A characteristic C or slow blow fuse 14 dotworkz amp D3 Exploded Detail Detau HEM NO PART NUMBER DESCRIPTION It C9TY 1 D_upper 2 D3lower V2 3 gqingepin 4 Main Gasket 5 UA Brkt VI CB 1007 V5 lens Gasket 5 Phillips Pan sheetmetal 15 dotworkz D3 Mounting Detail 2 00 ol He pe ur 5 90 AL AUI 3 8 Dia Bolt Clearance Holes Key slots 4 All dimension in inches
18. onduit mouth with finger tips till it usF with outside of Fitting 2 Pull wires La line installed length 5 Reaest steps 1 4 for any other conduit feeds a needed 2 Open Verl Slop Plug and install over wire 3 Pinch Plug lo compress over wire and insert inte conduil feed c ut bj Ta assum an alip hi seal caulk aruowi wires and cables coating enlre glug sarface with sealant t AN X y as wo dotworkz amp systems dotworkz amp Component Check List For D3 Included Standard Hardware for Camera Mounting IY o ee 18 32 Hexnut J 1 1 1507 0 25 Harrow Washer 2 025 Lock Washer 0 25 20 3 5 Long Hex Head Bolt TTTTE 6660o TIIE C9 9990 ho 32H 20 24V Input Blue Bypass Cable In MVP models only uc n Optional RP AXBR Bracket Direct Compatibility U ff Q IN Available by special order ao Axis 231D amp 232D nf N M DVTel 9840 OU J Merit LiLin PIH 7000 7600 7625 NG PiXORD P 463T Fast Speed Dome pa c Pelco Spectra IV Nu A Sony SNCRH124 SNC RS44N SNC RS46N L Toshiba IK DP30A dotworkz amp MVP Voltage Matrix Enclosure Input Camera Output Input Voltage to Enclosure The MVP Enclosures can be powered by Inputs of either High Voltage 110 220 VAC Or Low Volt 24 VAC VDC Site Power Available 110 220 VAC Power Source Single Phase Only a
19. or independent operation and therefore will switch on and off at slightly different set points when properly powered and wired This adds fail safe redundancy to system as well as electrical efficiency as second cooler only engages only at higher thermal loads Fully Seal Enclosure D3 COOLDOME is engineered to operate in fully sealed conditions only Failure to fully seal wire ports and all seals will allow unsatisfactory cooling and condensation to form within enclosure Always completely seal wire ports when completing wiring installation especially when using conduit even within inside wire feeds See Conduit guideline section in this manual for proper conduit installation Always create a Drip Loop on wiring that comes from overhead the enclosure to reduce the risk of water entering enclosure at wire seal ports Only use one round cable per provided wire port seal cable gland Attempting to run multiple separate wires thru one cable gland will create air and water leaks and will not seal properly Use of flat cable or zip cord will not allow cable gland ports to seal properly creating leaks and product damage Humidity Control Pack A Humidity control pack is provided to eliminate humidity in trapped air within COOLDOME Each COOLDOME product includes a canister that contains 40 grams of silica gel This will prevent moisture buildup inside of the CD housing Make sure to remove canister from its sealed foil packaging and secure into en
20. re no stray wire strands that can create short between wires and terminals Wiring Guidelines Dotworkz recommends wiring the low voltage 12VDC outputs so that there are two pairs of wires from the SP 500 P S outputs to power each cooler independently to reduce the need for very heavy wire gages on low voltage wiring run thus eliminating voltage drop issues Dotworkz recommends to keep all low voltage wiring runs as short as possible by installing step down power supply near to COOLDOME Dotworkz recommends using 12gg copper wire or thicker even on shortest wire runs of 20 ft or less wired between coolers and step down power supply per cooler SJOOW 12 4 type cable provides a stranded 4 conductor round bundle ideal for under 20 ft low voltage cabling when using our stock cable gland ports creating a good waterproof seal around cabling to enclosure Follow wire gage recommendation on table provided found on prior page for proper wire gage minimums based on distance between step down power and COOLDOME Voltage drop is based on fully loaded cooler engaged conditions and camera powered allowing up to 3 amps at typical ambient temperatures of 100F Inside D3 CD at rear of upper on enclosure will be two pairs of color coded screw terminal blocks to conveniently and securely attach low voltage wiring Always check voltage to assure 12VDC is properly wired into enclosure and observe proper polarity Each of the Coolers on the D3 are set up f
21. s automatically after fault condition is removed FAN CONTROL O T P RTH1 or RTH2 50 C FAN ON 45 C FAN OFF 70 C output shutdown FUNCTION REMOTE CONTROL RC RC Short power on Open power off 10 50 C Refer to output load derating curve 20 90 RH non condensing ENVIRONMENT 20 485 C 10 95 RH 0 034 C 0 50C 10 500Hz 2G 10min 1cycle period for 60min each along X Y Z axes SAFETY STANDARDS UL60950 1 TUV EN60950 1 approved WITHSTAND VOLTAGE UP O P 3KVAC lP FG 1 5KVAC O P FG 0 5KVAC SAFETY amp isoLATIONRESISTANCE P O P I P FG O P FG 100M Ohms 500VDC F Compliance to EN55022 CISPR22 Class B Compliance to EN61000 3 2 3 Compliance to EN61000 4 2 3 4 5 6 8 11 ENV50204 light industry level criteria A MTBF 1334Khrsmin MIL HDBK 217F 25C OTHERS 170 120 93mm L W H PACKING 1 9Kg 8pcs 15 5Kg 1 06CUFT D3 MVP Models High Voltage Inputs 90 264VAC 127 370VDC REQUENCY RANGE 47 63Hz EFFICIENCY Typ 74 1 ges eaw jew J OH AC CURRENT Typ 1 8A 115VAC 1A 230VAC INRUSH CURRENT Typ COLD START 60A 230VAC 30A 115VAC LEAKAGE CURRENT For earth 200uA 264VAC For patient lt 100uA 264VAC 115 150 rated output power Protection type Hiccup mode recovers automatically after fault condition is removed 18 5v 575 6757 t38 162v 1725 20257 284 324 s52 949V OVER VOLTAGE Protection type Shutdown o p voltage re power
22. tion on Camera Power Setup NON STANDARD CONNECTOR for instructions on how to power your camera Below are pictures of typical NON STANDARD CONNECTORS DC plugs with NO center pin Terminal pin connectors Terminal connector dotworkz amp Generic Camera Installation Height Example Align camera on D3 camera bracket so as to center camera s pan axis directly over center of camera plate provided The D3 camera bracket has been pre drilled with most of the popular camera mounting hole patterns Align pre drilled holes on camera plate to best fit your camera model Use hardware provided to secure to D3 camera plate On some camera models new holes may need to be drilled by installer to secure to D3 camera bracket or for installer to provide misc hardware to secure camera to provided D3 bracket Orientation of Camera Plate when installed into D3 Enclosure This edge nests in arch at front of D3 O 0 5 c o O This edge of the bracket faces back of the D3 Secure the camera plate to Steady Step slide bracket by using 4 28 32 Pan Head Machine screws into D3 Steady Step Camera Height Adjustment Brackets Steady Step brackets are the brushed aluminum brackets pre installed in every D3 enclosure Using the Steady Step brackets as illustrated in following pages Camera mounting plate can be adjusted to any height from 0 5 to over 6 by using 4 stepping ladder system Steady Step camera bracket is an easy t
23. wer Configuration D3 CD 12VDC Warning COOLDOME Enclosure runs on 12 VDC only If high voltage is applied directly to COOLDOME enclosure you will damage housing void warranty and create electrocution hazard that can be harmful or fatal Do not start wiring until you have fully read and understand these installation instructions External Power Supply Model SP 500 The step down power supply provided with each D3 COOLDOME must be mounted outside of the D3 enclosure This ower supply is must be mounted indoors or in an environmentally protective enclosure The power supply can be powered by 95 264 VAC single phase source voltage It is self ranging so no switch adjustment is needed if you power it from a 110 VAC source or 220 VAC source voltage single phase Optional outdoor rated sealed power supplies are available sold separately The output of the SP 500 is rated up to 40 amps peak output 12VDC Output 12 VDC can be tuned up or down 10 to optimize regulated output via a small nylon adjustment to left of 12V output terminals on face of power supply It is recommended to tune the voltage at power supply between 12 0 VDC 13 5 VDC in unloaded condition A higher voltage setting may create premature fan failure and settings above 15VDC may cause costly failure to main cooling components Use voltage meter to confirm all voltages before connecting COOLDOME to power supply Firmly tighten all screw terminal connections and check there a
24. ystems 1 is intact Failure to comply with the foregoing could result in the unit 619 224 LIVE 5483 for return authorization amp shipping instructions separating from the support structure and falling with resultant damages or injury to anyone or anything struck by the failing unit UNPACKING Unpack carefully Electronic components can be damaged if improperly handled or dropped If an item appears to have been damaged in shipment replace it properly in its carton and notify the shipper Be sure to save 1 The shipping carton and packaging material They are the safest material in which to make future shipments of the equipment 2 These Installation and Operating Instructions v For technical questions or product returns call Dotworkz Customer Service 866 575 4689 7 30 AM to 4 30 PM PST The proper technician will contact you as soon as possible The External Nut on All electrical wire feed Glands must be tightened to create a weather tight seal prior to putting D2 in service Failure to create this seal may result in water incursion into enclosure This may lead to electrical shock product failure and damage to electrical systems installed within enclosure including but not limited to damage to camera heater and blower circuitry cooling circuitry and other systems installed in unit A All screws on hinged lower must be tightened to create seal on enclosure Failure to create this seal may result in water incursion into e

Download Pdf Manuals

image

Related Search

Related Contents

OM, K3000, K3000 Wet, K 3000, K 3000 Wet, 2010  IMPORT ANTE  Physics 445L Modern Physics Laboratory Atomic Spectroscopy  T12VRHD- 12V Li-ion SDS Rotary Hammer Drill  Operating Instructions  EReCHD 本体を投附 附ど強 剛才 叩 機器の破損 故障の原因と HDM  Nextiva S1900e Series User Guide.book  334 201 Operating instructions Pneumatic rotary drive Type  