Home
TEKTRONIX DPO7104 Datasheet
Contents
1. 1 5 GHz differential probe P6330 8 3 GHz differential probe P6246 8 400 Mtz differential probe P6101B 1x passive probe 15 MHz TCPA300 TCPA400 Series current measurement systems P5200 P5205 P5210 8 High voltage differential probes P5100 P6015A High voltage probes Requires Opt SVE or SVEM 8 Probe requires TPA BNC adapter DPO7OOO Series e www tektronix com oscilloscopes 15 Digital Phosphor Oscilloscopes DPO7000 Series Cables GPIB Cable 1 m Order 012 0991 01 GPIB Cable 2 m Order 012 0991 00 RS 232 Cable Order 012 1298 00 Centronics Cable Order 012 1214 00 Accessories Mini Keyboard USB interface Order 119 7083 00 Keyboard USB interface Full size keyboard with 4 port USB hub Order 119 6297 00 Service Manual Order 071 1 740 xx Instrumented DIMM for DDR3 Order scope NEXVu card for UDIMM Raw Card E Contact www nexustechnology com Transit Case Order 016 1970 00 Video Display Clamp Order Order 013 0278 xx Rackmount Kit Order 016 1985 xx Removable HD Spare Order 065 0744 xx Oscilloscope Cart Order K420 requires 407 5192 00 bracket set Thermal Printer Paper Order 016 1969 00 WaveStar Windows application for remote access Test Fixtures TDSUSBF Test fixture for use with Opt USB Probe Calibration Power Deskew Fixture Order 067 1686 xx Ethernet Test Fixture Order t
2. 10 000 ft 3 048 m Nonoperating 40 000 ft 12 190 m Random Vibration Operating 0 000125 G2 Hz from 5 to 350 Hz 3 dB octave from 350 to 500 Hz 0 0000876 G2 Hz at 500 Hz Overall level of 0 27 GRMS Nonoperating 0 0175 G2 Hz from 5 to 100 Hz 3 dB octave from 100 to 200 Hz 0 00875 G2 Hz from 200 to 350 Hz 3 dB octave from 350 to 500 Hz 0 006132 G2 Hz at 500 Hz Overall level of 2 28 GRMS Regulatory Electromagnetic Compatibility 93 68 EEC EN61326 1997 A1 1998 A2 2000 Certifications UL 3111 1 CSA1010 1 ISO11469 EN61010 1 IEC 61010 1 Ordering Information DPO7OOO Series DPO7054 500 MHz Digital Phosphor Oscilloscope DP07104 1 GHz Digital Phosphor Oscilloscope DP07254 2 5 GHz Digital Phosphor Oscilloscope DP07354 3 5 GHz Digital Phosphor Oscilloscope for Serial and Digital applications All Models Include Accessory pouch front cover mouse quick start user manual 071 1 73x xx DPO7000 Series product software media DPO7000 series operating system restoration media Optional applications software media performance verifica tion procedure PDF file GPIB programmer s refer ence on product software media calibration certificate documenting NIST traceability Z 540 1 compliance and ISO9001 power cord one year warranty Note User to specify quick start user manual language and power plug when ordering DPO7054 also includes 4 P6139A 500 MHz
3. RECOVERED RECOVERED PROBE DATA CLOCK COMPENSATION Loa Pere rmm OO Lo Lay 10 ocale Scale Tn nari wii nin CAN and LIN Timing and Protocol Decode 1 Large 12 1 inch XGA Touch Screen Display The DPO7000 series touch screen gives up to 15 more waveform display than other oscilloscopes of its class 2 New Probe interface TekVPI probe interface provides versatility and ease of use enabled by intelligent bi directional oscilloscope to probe communication 3 Exceptional Performance The fastest waveform capture rate on the highest bandwidth oscilloscope in a mid range offering with up to 40 GS s real time sample rate and 400 M record length on one channel DPO7OOO Series www tektronix com oscilloscopes With MultiView Zoom Easily dive into very long record of acquired data analyze multiple waveform segments simultaneously and scroll automatically through the deepest records visually 5 Unmatched Usability With MyScope create your own control window with only the controls you care about The versatile user interface allows you to use the touch screen or the mouse Accelerate the Debug of Complex Designs with Pinpoint Triggering Access up to 1400 trigger combinations to address virtually any triggering Situations 7 FastAcq Acquisi tion Expedites Debugging by Clearly Showing Faults More than 250 000 waveforms per second and with a
4. 10x passive probes Probes and accessories are not included in the oscilloscope warranty Refer to the data sheet for each probe for its unique warranty and calibration terms Options Instrument Options Record Length Options Opt 2RL 80 MSamples max 20 MSamples ch Opt 5RL 200 MSamples max 50 MSamples ch DPO7254 DP07354 only Opt 10RL 400 MSamples max 100 MSamples ch Hardware Options Opt 1P Thermal printer in the pouch Printer option is available for all models DPO7104 DPO7054 only Opt 2SR 2 Double maximum real time sample rate DP07104 40 GS s 1 channel 20 GS s 2 channels 10 GS s 3 or 4 channels DP07054 20 GS s 1 channel 10 GS s 2 channels 5 GS s 3 or 4 channels Software Options Opt DDRA DDR Memory Bus Analysis Opt DJA DPOJET Jitter and Eye Diagram Analysis Advanced Opt DJE DPOJET Jitter and Eye Diagram Analysis Essentials Opt LSA Low Speed Serial Analysis includes CAN LIN Trigger Decode and Analysis Opt MTM Mask Testing for Serial Communication Standards up to 1 5 Gb s Includes hardware clock recovery on DPO7254 DP07354 1 DP07254 or DPO7354 only 2 DP07054 and DPO7104 only 3 Requires DJA and ASM Opt LT Limit Testing Opt ASM Advanced Event Search and Mark Opt ET3 TDSET3 Ethernet Compliance Test software Opt USB TDSUSBS USB 2 0 Compliance Test software only Opt
5. Box Peak Hits Median Maximum Minimum Peak to Peak Mean u Standard Deviation sigma U 1sigma U 2sigma U 3sigma Eye Pattern Related Extinction Ratio absolute dB Eye Height Eye Width Eye Top Eye Base Crossing Jitter 0 p RMS 6sigma Noise p p RMS Signal Noise Ratio Cyele Distortion Q Factor Waveform Processing Math Arithmetic Add Subtract Multiply Divide Waveforms and Scalars Algebraic Expressions Define extensive alge braic expressions including Waveforms scalars UserAdjustable Variables and Results of Parametric Measurements g Integral CH 1 Mean CH 1 x1 414xVAR1 Math Functions Average Invert Integrate Differentiate Square Root Exponential Log10 Log e Abs Ceiling FloorMin Max Sin Cos Tan ASin ACos Alan SinsCoshs Tanh Relational Boolean result of comparison gt lt gt lt a l Frequency Domain Functions Spectral Magnitude and Phase Real and Imaginary Spectra Vertical Units Magnitude Linear dB dBm Phase Degrees radians group delay IRE and mV units Window Functions Rectangular Hamming Hanning Kaiser Bessel Blackman Harris Gaussian Flattop2 Tek Exponential Waveform Definition As an arbitrary math expression Filtering Functions User definable filters Users specify a filter containing the coefficients of the filter Filter files provided Mask Function A function that gene
6. EVM vs symbol EVM vs Subcarrier Common Phase Error vs Symbol and Voltage vs Time plots and complete measure ments are captured and documented for each test condition Digital Phosphor Oscilloscopes DPO7000 Series Ses ss a e ed ee eee f multiple domains SignalVu Vector Signal Analysis Opt SVE SVP SVM Easily validate wideband designs and characterize wideband spectral events By combining the signal analysis engine of the RSA6100A Real Time Spectrum Analyzer with that of the industry s widest bandwidth digital oscilloscopes you can now evaluate complex signals up to 20 GHz without the need of an external down converter You get the functionality of a vector signal analyzer a spectrum analyzer and the powerful trigger capabilities of a digital oscillo scope all in a single package Whether your design validation needs include wideband radar high data rate satellite links or frequency hopping communications Signalvu vector signal analysis software can speed your time to insight by showing you time variant behavior of these wideband signals DPO7OOO Series www tektronix com oscilloscopes 7 Digital Phosphor Oscilloscopes DPO7000 Series Basic spectral Ul control window F ispi THe ee E af 9 5 12 TOR Tektroni DPO 7254 Digital Phosph r Oscilloscope ie E r a nd O Baa a 40 0GSia 25 0paip Samplu K 273 408 acqs 4 September 19 70045
7. UWBE Ultra Wideband Spectral Analysis Essentials Opt UWB Ultra Wideband Spectral Analysis software Opt PWR DPOPWR Power Measurement and Analysis Software Opt SVE SignalVu Essentials Vector Signal Analysis Software Opt SVP Advanced Signal Analysis including pulse measurements Requires option SVE Opt SVM General Purpose Modulation Analysis Requires option SVE DPO7254 DP07354 only Opt PTM 8b 10b protocol triggering and NRZ serial pattern triggering Includes hardware clock recovery up to 1 5 Gb svand pattern lock triggering Opt RTE RT Eye Serial data compliance and analysis software DPO7354 only Opt DVI Digital Visual Interface compliance test software Bundle Options Opt PS1 Power Bundle optionancludes TPA BNC adapter Probe Calibration and deskew fixture 067 1686 xx P5205 TCPQ030_and Opt PWR User Manual Options Opt LO Englishsmanual Opt L1 French manual Opt L3 German manual Opt amp 5 Japanese manual Opt L7 Simple Chinese manual Opt L8 Standard Chinese manual Opt L9 Korean manual Opt L10 Russian manual Power Plug Options Opt AO North America Opt A1 Universal European Union Opt A2 UK Opt A3 Australia Opt Ad Switzerland Opt A6 Japan Opt A10 China Opt A11 India Opt A99 No power cord 4 Requires Ethernet Test Fixtur
8. YT and XY display modes make it easy to investigate phase relationships and Safe Operating Area violations Select from 53 automatic measurements using a graphical palette that logically organizes measurements into Amplitude Time Combination Histogram and Communications categories Gather further insight into your measurement results with statistical data such as mean min max standard deviation and population Define and apply math expressions to waveform data for on screen results In terms that you can use Access common waveform math functions with the touch f button Or for advanced applications create algebraic expres sions censisting of live waveforms reference waveforms math functions measurement values scalars and user adjustable variables with aa easy to use Calculator style editor FFT Jo analyze your signal in the spectral domain use the basic spectral provides you with the best parameter or use advanced spectral with the manual time base horizontal mode to directly control the frequency span center frequency and resolution bandwidth Digital Phosphor Oscilloscopes DPO7000 Series An integrated toolset for digital design and troubleshooting Basic spectral Ul control window Filtering Enhance your ability to isolate or remove some important component of your signal noise or specific harmonics of the signal by creating your own filters or using the filters provided as standard wi
9. Your High speed Serial Designs Optional NRZ Serial Pattern triggering plus Recovered Clock and Recovered Data avail able on the front of the DPO7254 or the DPO7354 instruments Event Search and Mark for faster event analysis Advanced Jitter and Timing application specific and compli ance measurements and tests DPO7OOO Series e www tektronix com oscilloscopes 9 Digital Phosphor Oscilloscopes DPO7000 Series Characteristics Vertical System DPO7054 DPO7104 DPO7254 DPO7354 Input Channels 4 Bandwidth DSP Bandwidth Enhance n a n a n a 3 5 GHz Risetime DSP Bandwidth Enhance n a n a n a 115 ps Hardware Analog Bandwidth 3 dB 500 MHz 1 GHz Z o GNZ 2 5 GHZ Rise Time 10 to 90 typical 460 ps 300 ps 160 ps 145 ps Rise Time 20 to 80 typical 310 ps 200 ps 100 ps 95 ps DC Gain Accuracy 1 with offset position set to 0 Bandwidth Limits Depending on instrument model 3 0 GHz 2 5 Ghz 2 Ghz 1 GHz 500 Mhz 250 Mhz or 20 Mhz Input Coupling AC DC GND Input Impedance software selectable 1 MQ 1 with 13 pF 2 pF or 50 Q 1 Input Sensitivity 1 MQ 1 mV div to 10 V div 50 Q 1 mV div to 1 V div Vertical Resolution 8 bit gt 11 bit with averaging Max Input Voltage 1 MQ 150 V CAT I derate at 20 dB cecade to 9 Vey above 200 kHz Max Input Voltage 50 Q 5 Vays With peaks less than 24 V Position Range 5 divisions Offset Range tamV div to 50 mV div 1 V 50 5 mV div to 99 5 mV div 1 5 V to 10 Divisions 100 mV d
10. other encoded serial data streams or you can set the desired encoded words for the serial pattern trigger to capture This serial trigger option covers NRZ serial standards up to 1 25 Gb s Triggering on an analog HDTV tri level sync signal and examining horizontal blanking interval Pattern Lock Triggering adds a new dimension to NRZ serial pattern trig gering by enabling the oscilloscope to take synchronized acquisitions ofa long serial test pattern with outstanding time base accuracy Pattern lock triggering can be used to remove random jitter from long serial dataypatterns Effects of specific bit transitions can be investi gated and_averaging can be used with mask testings This feature is included as part of Option PIM on the DP 7254 and 7354 models Large 12 1 inch XGADisplay Screen The DPQ7000 Seri s has the largest display in the industrywith a 12 1 XGA touchscreen that gives up to 15 more waveform display than other oscilloscope series in its class 10 vertical divisions give you 25 more vertical measurement resolution 4 DPO7OOO Series e www tektronix com oscilloscopes Serial pattern triggering to debug pattern dependent issues Unmatched Usability The TekVPI probe interface provides versatility and ease of use enabled by intelligent bi directional oscilloscope to probe communication The DPO7000 Series are fast responding instruments and contain a comprehensive suite of features such as a t
11. 100 1000Base T signals Optional USB Compliance Testing Opt USB Provides compliance testing for USB 2 0 signals Optional DDR Memory System Analysis Opt DDRA Accelerate the validation of a memory system based on DDR1 LP DDR1 DDR2 DDR3 or DDR variants technology like GDDRS This new DDR search algorithm auto matically detects the rates and the voltage levels of the data and strobe signals and marks every occurrence of read or write bursts You can then generate an eye diagram of the data or perform JEDEC standard measure ments qualified on read or write bursts with DPOJET Optional Ultra Wideband Spectral Analysis and Ultra Wideband Spectral Analysis Essentials UWBE Ultra Wideband microwave optical and electrical signals require more real time bandwidth than is possible with spectrum analyzer based solutions Spectral analysis and digital down conversion of RF data is fast and easy and the down converted frequency span of interest may be exported for further analysis in tools such as RSAVu and MATLAB USB compliance testing E pa jpa TU Ethernet compliance testing UWB in addition adds With aut matic packet TFC and data rate detec tion support for all bandgroups Time Frequency Codes and data rates WiMedia PHY 1 2 analysis provides a complete solution Rapid visualization debug and seport generation of the spectrograms power spectral density QPSK DCM constellations
12. 4 only BNC connector lt 1 25 Gb s Output swing 200 mV into 50 Q Requires option to enable USB 2 0 Port One USB 2 0 connector Aux Trigger Input See Trigger specification DPO7OOO Series e www tektronix com oscilloscopes 13 Digital Phosphor Oscilloscopes DPO7000 Series Side Panel Parallel Port IEEE 1284 DB 25 connector Audio Ports Miniature phone jacks disabled Keyboard Port PS 2 compatible Mouse Port PS 2 compatible USB Ports Four USB 2 0 connectors LAN Port RJ 45 connector supports 10Base T 100Base T and Gigabit Ethernet Serial Port DB 9 COM1 port VGA Video Port DB 15 female connector connect a second monitor to use dual monitor display mode Supports basic requirements of PC99 specifications Oscilloscope VGA Video Port DB 15 female connector 31 6 kHz sync EIA RS 343A compliant connect to show the oscilloscope display including live waveforms on an external monitor or projector Rear Panel Power 100 to 240 VRMS 10 47 to 63 Hz lt 550 W 115 VRMS 10 400 Hz CAT lt 500 VA Analog Signal Output BNC connector provides a buffered version of the signal that is attached to the Ch 3 input Amplitude 50 mV div 20 into a 1 MQ load 25 mV div 20 into a 50 Q load Bandwidth 100 MHz into a 50 Q load Software Switchable BNC Connector External Time Base Reference In BNC connector time base system can p
13. 7354 as part of Opt LSA Serial Pattern option PTM Captures serial data stream with built in clock recovery for NRZ stan dards up to 1 25 Gb s Extended with pattern lock triggering to capture repeated acquisitions of long serial test patterns Search and Mark Events Basic Mark any events and document wave forms Search positive negative slopes or both on any channels Event table summarizes all found events All events are time stamped in reference to trigger position Users can choose to stop acquisi tions when an event is found Advanced Search glitches or runts as well as transition rate pulse width setup and hold timeout window violations or find any logic or state pattern on any number of channels Search DDR read or write bursts with Opt DDRA Waveform Measurements Automatic Measurements 53 of which 8 can be displayed on screen at any one time measurement Statistics user definable reference levels measure ment within gates isolating the specific occurrence within an acquisition to take measurements on Amplitude Related Amplitude High Low Maximum Minimum Peak to Peak Mean Cycle Mean RMS Cycle RMS Positive Overshoot Negative Overshoot Time Related Rise Time Fall Time Positive Width Negative Width Positive Duty Cycle Negative Duty Cycle Period Frequency Delay Combination Area Cycle Area Phase Burst Width Histogram Related Waveform Count Hits in
14. Complex Electrical Designs FastAcq Acquisition Mode Expedites Debugging by Clearly Showing Imperfections More than just color grading FastAcq enabled by Tektronix proprietary DPX acquisition technology captures signals up to more than 250 000 waveforms per second on all 4 channels simulta neously dramatically increasing the probability of discovering infrequent fault events And with a simple turn of the intensity Knob you can clearly see a world others don t see because frequency of occurrence is color coded Some oscilloscope vendors claim high waveform capture rates for short bursts of time but only the DPO7000 Series Isolate glitches down to 200 ps wide enabled by DPX technology can deliver these fast waveform capture rates on a sustained basis saving minutes hours or even days by quickly revealing the nature of faults so sophisticated trigger modes can be applied to isolate them The Ability to Trigger an Oscilloscope on Events of Interest is Paramount in Complex Signal Debug and Validation Whethenyou re trying to finda system erromer need to Isolate asectio of a complex signal for further analysis like a DDR read or write bursty Tektronix Pinpoint triggering provides the solu tion The Pinpoint trigger system uses Silicon Germanium SiGe technology to provide trigger sensitivity of up to the bandwidth of the instrument and allows selection of most trigger types on both Avand B trig
15. DPO07104 DP07254 DPO7354 FastAcg Acquisition Mode FastAcq optimizes the instrument for analysis of dynamic signals and capture of infrequent events Maximum FastAcg Waveform Capture Rate _ gt 250 000 wims s on all 4 channels simultaneously Waveform Database Accumulate waveform database providing three dimensional array of amplitude time and counts Sample Acquire sampled values Peak Detect Captures narrow glitches at all real time sampling rates 1 sample rate at lt 10 GS s Averaging From 2 to 10 000 waveforms included in average Envelope From 1 to 2x109 waveforms included in min max envelope Hi Res Real time boxcar averaging reduces random noise and increases resolution FastFrame Acquisition Acquisition memory divided into segments maximum trigger rate gt 310 000 waveforms per second Time of arrival recorded with each event Frame finder tool helps to visually identify transients Roll Mode Up to 10 MS s with a maximum record length of 40 M DPO7000 Series www tektronix com oscilloscopes 11 Digital Phosphor Oscilloscopes DPO7000 Series Pinpoint Trigger System DPO7054 DP07104 DP07254 DPO7354 Sensitivity Internal DC Coupled 0 7 div DC to 50 MHz increasing to 1 2 div at rated analog bandwidth typical 2 5 div at 3 5 GHz with DSP Bandwidth enhance External Auxiliary Input 1 MQ 200 mV from DC to 50 MHz increasing to 350 mV at 250 MHz typical Trigger Characteristics A Event and Delayed B Event Trigger Types Edge Glitch
16. Easily create your ow personalized toolbox of oscilloscope features in a matter of minutes using a simple visual drag and drop process Once created these lt custom control windows are easily accessed through a dedicated MyScope button and menu selection on the oscilloscope button menu bar just like any other control window You can make an unlimited number of custom control windows enabling each person who uses the oscilloscope in a shared environment to have their own unique control window MyScope control windows will benefit all oscilloscope users eliminating the ramp up time that many face when returning to the lab after not using an oscilloscope for a while and enables the power user to be far more efficient Everything you need is found in one control window rather than having to constantly navigate through menu after menu to repeat similar tasks 2 DPO7OOO Series e www tektronix com oscilloscopes Tii med eager eee be ee ee Drag and drop menu items of interest to create the MyScope control window Eje ia pee paa me pa pe ete coe pa ee I ie Aran ons if i DP 2 AFF Capture data into Microsoft Excel using the unique Excel toolbar and create custom reports using the Word toolbar With OpenChoice Software Customize Your Test and Measurement System with Familiar Analysis Tools The analysis and networking features of OpenChoice software add flexibility to Tektronix Windows XP oscilloscopes Using
17. Runt Width Transition Time Timeout Pattern State Setup Hold Window all except Edge Pattern and State can be Logic State qualified by up to two channels Low Speed Serial Protocol IC SPI and RS 232 standard CANbus available as Opt LSA Trigger Type A Event onl Trigger on address data and special handshaking states and other conditions Main Trigger Modes Auto Normal and Single Enhanced Triggering User selectable it corrects the difference in timing between the trigger path and the acquired data path it supports all Pinpoint trigger tyoes on both A and B Events except pattern trigger and not available in FastAc Trigger Sequences Main Delayed by Time Delayed by Events Reset by Time Reset by State Reset by Transition All sequences can include separate horizontal delay after the trigger event to position the acquisition window in time Communications Related Triggers Requires Opt MTM Support for AMI HDB3 BnZS CMI MLT3 and NRZ encoded communications signals Select among isolated positive or negative one zero pulse form or eye patterns as applicable to the standard Serial Pattern Trigger On DPO7254 or DPO7354 only and requires Opt PTM Up to 64 bit serial word recognizer bits specified in binary high low don t care or hex format Trigger on NRZ encoded data up to 1 25 Gb s Video Type Trigger Formats and Field Rates Triggers from negative sync composite video field 7 or field 2 for interlaced ed any field specific line or any l
18. Se E E pis it CAN and LIN Timing and Protocol Decode CAN and LIN Timing and Protocol Decode Software Opt LSA When you need to ensure seamless and reli alole operation of a CAN or LIN network this option enables CAN bus triggering and provides the solution to measure oscillator tolerance propagation delay and simultaneously decode CAN and LIN messages with the protocol lever aging the trigger capabilities This option is offered on DPO7354 DPO7254 DPO7104 and DPO7054 as Opt LSA Optional Power Measurement and Analysis Opt PWR Analyze power dissipation in power supply switching devices and magnetic components and generate detailed reports in customiz able formats The HiRes acquisition mode delivers greater than 8 bits of vertical resolution on single shot or repetitive signals at bandwidth up to 125 MHz The powerful and flexible measurements math and math on math capabilities make it an ideal solu tion for performing power measure ments such as voltage current instan taneous power and energy for power device designers The new TekVPI interface provides smart communication between the oscilloscope and the probe TekVPI probe interface also provides more power to the probe interface allowing customers to directly connect current probes to the front of the oscilloscope Power Measurement and Analysis Optional Ethernet Compliance Testing Opt ET3 Provides compliance testing for 10
19. TM Opt MTM PWR Opt PWR SVEM Opt SVE SVP Opt SVP SVM Opt SVM Other Upgrades PTM To upgrade DP07254 or DPO7354 with Opt PTM CP2 8 TDSGRM2 ANSI ITU Telecom pulse compliance testing software requires Opt MTM on DPQ 000 Series J2 DSDDM2 disk drive analysis software tP Thermal Printer Requires Opt SVE or SVEM 8 Requires Opt MTM Belgium 07 81 60166 Brazil amp South America 11 40669400 Canada 1 800 661 5625 Central East Europe Ukraine and the Baltics 41 52 675 3777 Central Europe amp Greece 41 52 675 3777 Denmark 45 80 88 1401 Finland 41 52 675 3777 France 33 0 1 69 86 81 81 Germany 49 221 94 77 400 Hong Kong 852 2585 6688 India 91 80 22275577 Italy 39 02 25086 1 Japan 81 3 6714 3010 Luxembourg 44 0 1344 392400 Mexico Central America amp Caribbean 52 55 5424700 Middle East Asia and North Africa 41 52 675 3777 The Netherlands O90 02 021797 Norway 800 16098 People s Republic of China 86 10 6235 1230 Poland 41 52 675 3777 Portugal 80 08 12370 Republic of Korea 82 2 6917 5000 Russia amp CIS 7 495 7484900 South Africa 27 11 206 8360 Spain 34 901 988 054 Sweden 020 08 80371 Switzerland 41 52 675 3777 Taiwan 886 2 2722 9622 United Kingdom amp Eire 44 0 1344 392400 USA 1 800 426 2200 For other areas contact Tektronix Inc at 1 503 627 7111 Updated 12 November 2007 For Further I
20. Test Equipment Solutions Datasheet Test Equipment Solutions Ltd specialise in the second user sale rental and distribution of quality test amp measurement T amp M equipment We stock all major equipment types such as spectrum analyzers signal generators oscilloscopes power meters logic analysers etc from all the major suppliers such as Agilent Tektronix Anritsu and Rohde amp Schwarz We are focused at the professional end of the marketplace primarily working with customers for whom high performance quality and service are key whilst realising the cost savings that second user equipment offers As such we fully test amp refurbish equipment in our in house traceable Lab Items are supplied with manuals accessories and typically a full no quibble 2 year warranty Our staff have extensive backgrounds in T amp M totalling over 150 years of combined experience which enables us to deliver industry leading service and support We endeavour to be customer focused in every way right down to the detail such as offering free delivery on sales covering the cost of warranty returns BOTH ways plus supplying a loan unit if available and supplying a free business tool withevery order As well as the headline benefit of cost saving second user offers shorter lead times higher reliability and multivendor solutions Rental of course is ideal for shorter term needs and offers fast delivery flexibility try before you buy zero capital expendi
21. ate between the events of interest effortlessly A basic event edge only search and mark is provided as a standard feature and support for more advanced event types like transition setup and held or logic pattern is provided with the ASM option Limit Testing Opt LT This feature consists of comparing an acquired waveformrto Oundaries These bourd aries are typically defined by the user to specify a tolerance band around a reference waveform If any part ofthe acquired waveform falls outside of the limit the software returns a failure message and the location of the failure is Shown on the waveform Communications Mask Testing Opt MTM This feature provides a camplete portfolio of masks for verifying compliance to serial communications standards It supports 156 Standards Masks ITU T 64 Kb s to 155 Mb s ANSI 11 102 1 544 Mb s to 155 Mb s Ethernet IEEE 902 3 ANSI X3 263 125 Mb s to 1 25 Gb s Sonet SDH 51 84 Mb s to 622 Mb s Fibre Channel 133 Mb s to 2 125 Gb s USB 12 Mb s to 480 Mb s IEEE 1394 491 5 Mb s to 1 966 Gb s Rapidl O up to 2 Gb s OIF Standards 1 244 Gb s Video 143 18 Mb s to 1 485 Gb s 6 DPO7OOO Series e www tektronix com oscilloscopes T i oooG OO Be oO ANTS Pr ores T j mam T il EA m aa iss ME EC ECE EE st Saima o aida batai EA ELELCOOCELTCA pepe EE ase peat Es Ea ieme ume OE E ae eee a ee
22. d phase tinearity within the newdtrequency range therebyreducing the effects of out of batad noise on measurements Now designerscean purchase one instrument for their highest bandwidth needs and easily optimizeat to handle lower frequency meas urements as well lt Very low jitter noise floor and vertical accuracy for very accurate measurements Longest acquisition of the industry to provide more resolution and longer time sequence Standard 10 million data points per channel on the DPO7000 Series Optional up to 400 million total data points on 2 5 GHz and 3 5 GHz models 3 5 GHz DSP 3 0 GHz DSP 500 MHz DSF 250 0 MHz H 20 0 MHz H User selectable bandwidth limiting choices Features amp Benefits 3 5 GHz bandwidth model for serial and digital applications 2 5 GHz 1 GHz and 500 MHz band width models for all applications Up to 40 GS s real time sample rate on one channel and up to 10 GS s on all four channels Up to 400 megasamples record length with MultiView Zoom feature for quick navigation gt 250 000 WFMS s maximum wave form capture rate User selectable bandwidth limit filters for better low frequency measurement accuracy MyScope custom windows and right mouse click menus for exceptional efficiency Event search and mark to facilitate the comprehension of event relationships Pinpoint triggering provides the most flexible and highest perform ancetriggering w
23. e Requires TDSUSBF USB Test Fixture 6 DP07354 only Digital Phosphor Oscilloscopes DPO7000 Series Service Options Probes and accessories are not included in the oscilloscope warranty Refer to the data sheet for each probe for its unique warranty and calibration terms Opt C3 Calibration Service 3 Years Opt C5 Calibration Service 5 Years Opt D1 Calibration Data Report Opt D3 Calibration Data Report 3 Years with Opt C3 Opt D5 Calibration Data Report 5 Years with Opt Cd Opt R3 Repair Service 3 Years Opt R5 Repair Service 5 Years Recommended Accessories Probes TCP0150 20 MHz TekVPI AC DC 150 A current probe TCP202 DC coupled current probe TDP0500 500 MHz TekVPI high voltage differential probe 1DP1000 1 Ghz TekVPI high voltage differential probe TDP1500 1 5 GHz TekVPI high voltage differential probe TDP3500 3 5 GHz TekVPI high voltage differential probe TAP3500 3 5 GHz TekVPI active single ended probe TAP2500 2 5 GHz TekVPI active single ended probe TAP1500 1 5 GHz TekVPI active single ended probe TCP0030 gt 120 MHz TekVPI AC DC 30 A current probe TPA BNC TekProbe BNC Level 2 to TekVPI adapter P6139A 500 MHz passive probe P6158 3 GHz 20x low C probe P6247 8 1 GHz differential probe P6243 8 1 GHz active probe P6245 8 1 5 GHz active probe P6248 8
24. e triggering is a Standard feature and includes trig gering on a data pattern within a user definable frame RS 232 triggering is a standard feature CAN Controller Area Network trig gering is an optional feature Opt LSA and includes synchronization to the Start or End of a CAN frame on any CAN high or CAN low signal triggering on Type of Frame Data Remote Overload Identifier Data Missing Acknowledge and Bit Stuffing error DPO7OOO Series e www tektronix com oscilloscopes 3 Digital Phosphor Oscilloscopes DPO7000 Series Easily trigger on a specific IC address Analog HDTV EDTV Triggering for emerging standards like 1080i 1080p 720p and 480p as well as standard video triggering on any line within a field all lines all fields odd or even fields for NTSC SECAM and PAL video signals In addition IRE and mV gratic ules can be selected for easier meas urements and visual inspection This is a standard feature Serial Pattern Triggering To debug serial architectures use the serial pattern triggering option for NRZ serial data stream with built in clock recovery available on models DPO7254 and DPO7354 only The instrument can recover the clock signal identify the transitions and decode characters and other protocol data With the combina tion of the Serial Trigger and Protocol Decode software you can see the captured bit sequences decoded into their words for convenient analysis for 8 b 10 b and
25. ger circuits It can capture very narrow glitches with very little trigger jitter Other trigger systems offer multiple trigger types only on a single event A event with delayed trigger B event selection limited to edge type triggering and often do not provide a way to reset the trigger sequence if the B event doesn t occur But Pinpoint triggering provides a full suite of advance trigger types on both A and B triggers with reset triggering to begin the trigger sequence again after a specified time state or transition so that even events in the most complex signals can be captured Other oscilloscopes Isolate setup and hold violations down to 360 ps typically offer less than 20 trigger combi nations Pinpoint triggering offers over 1400 combinations all at full perform ance With enhanced triggering you can chogse to compensate for the difference in time there is between the trigger path anad the display path and eliminate virtu ally any trigger jitter at the trigger point In this mode the trigger point can be used as a measurement reference Trigger on the Most Relevant Bit Sequence of the Industry Standard Serial Bus 2C Inter Integrated Circuit triggering is a standard feature and includes Start condition Missing Acknowledge Restart Data Read Address and or Data Frame in a 10 bit or 7 bit format with a specific selection to choose whether or not to include the RAW bit SPI Serial Peripheral Interfac
26. hase lock to external 10 MHz reference Time Base Reference Out BNC connector provides TTL compatible output of internal 10 MHz reference oscillator Aux Trigger Output BNC connector provides a TTL compatible polarity switchable pulse when the oscilloscope triggers GPIB Port IEEE 488 2 standard Physical Characteristics Benchtop Configuration Dimensions mm in Height 292 11 48 Width 451 17 75 Depth 265 10 44 Weight kg Ibs Net 15 32 Shipping 28 9 63 75 Rackmount Configuration Dimensions mm iN Height 323 12 25 Width 419 18 85 Depth from 231 75 9 12 rackmounting ear to back of instrument Weight kg Ibs Net 17 4 Fa Rackmount Kit AG 9 0 Mechanical Cooling Required Clearance mm in Top 0 0 Bottom 0 0 Left side 76 3 Right side 0 0 Front 0 0 Rear 0 0 14 DPO7000 Series www tektronix com oscilloscopes Environmental Temperature Operating 0 C to 50 C excluding CD R W drive 10 C to 45 C including CD R W drive Nonoperating 40 C to 71 C Humidity Operating 5 to 95 relative humidity RH with a maximum wet bulb temperature of 29 C at or below 50 C noncondensing Upper limit derated to 45 RH above 30 C up to 50 C Nonoperating 5 to 95 relative humidity RH with a maximum wet bulb temperature of 29 C at or below 60 C noncondensing Upper limit derated to 45 RH above 30 C up to 50 C Altitude Operating
27. hrough Crescent Heart Software htto www c h s com Adapters AMT75 1 GHz 75 Q adapter P6701B Optical electrical converter multi mode P6703B Optical electrical converter single mode 1 Probe requires TPA BNC adapter 2 DP07254 or DP07354 only 3 DP07354 only 4 Requires DJA and ASM 5 Requires Ethernet Test Fixture 6 Requires TDSUSBF USB Test Fixture Contact Tektronix ASEAN Australasia 65 6356 3900 Austria 41 52 675 3777 Balkans Israel South Africa and other ISE Countries 41 52 675 3777 Instrument Upgrades To upgrade your DPO7000 Series Oscilloscope order option as noted To upgrade record length DPO7UP with Opt RLO2 From standard configuration to Opt 2RL configuration RLO5 From standard configuration to Opt SRL configuration RLO10 On DP07254 or DPO7354 from standard configuration to Opt 10RL configuration RL25 From Opt 2RL configuration to Opt SRL configuration RL210 2 On DPO7254 or DPO7354 from Opt 2RL configuration to Opt 10RL configuration RL510 On DP07254 or DPO7354 from Opt ORL configuration to Opt 10RL configuration To upgrade DPO7000 Series with DVI Opt DVI RTE Opt RTE or TDSRT Eye software LSA Opt LSA LT Opt LT ASM Opt ASM DDRA Opt DDRA DJAM Opt DJA DJEM Opt DJE ET3 Opt ETS USB 6 Opt USB UWBE OptUWBE UWB Opt UWB M
28. ine for interlaced or noninterlaced systems Supported systems include NTSC PAL SE AMband HDTV 1080 24sF 1080p 25 t080i 50 1080i 60 1080p 24 720p 60 480p 60 Clock Recovery System On DPO07254 or DPO7354 only and requires Opt PIM or MTM Clock Recovery Phase Fixed at FBaud 500 Locked Loop Bandwidth Frequency Range 1 5 MBaud to 1 25 GBaud Clock Recovery Jitter RMS 20 PSgys 1 25 Unit Interval RMS for PRBS data patterns 20 PSpus 1 25 Unit Interval RMS for repeating 001 1 lt data pattern Tracking Acquisition Range 5 of requested baud typical Minimum Signal Amplitude 1 div up to 1 25 GBaud typical needed for Clock Recovery Trigger Level Range Internal 12 divisions from center of screen AUX Trigger TekVPI interface 5 V 50 150 V CAT derate at 20 dB decade to 9 Vay above 200 KHz 1 MQ Line Fixed at 0 V Trigger Couplin DC AC attenuates lt 60 Hz KF Rej attenuates gt 30 kHz LF Rej attenuates lt 80 kHz Noise Reject reduces sensitivi Trigger Holdoff Range 250 ns min to 12 S max 12 DPO7000 Series e www tektronix com oscilloscopes Trigger Modes Edge Positive or negative slope on any channel or front panel auxiliary input Coupling includes DC AC noise reject HF reject and LF reject Glitch Trigger on or reject glitches of positive negative or either polarity Minimum glitch width is down to 170 ps typical with rearm time of 250 ps for DPO7254 or DPO7354 Width Trigge
29. ing debugging and testing sophisticated electronic designs The family features exceptional perfor mance in signal acquisition and analysis operational simplicity and unmatched debugging tools to accelerate your day to day tasks The largest screen in the industry and the intuitive user interface provide easy access to the maximum amount of information Unmatched Acquisition Performance Signal Fidelity of Tektronix Oscilloscopes Ensures Confidence in Your Measurement Results High sample rate on all models on all channels to capture more signal details transients imperfections fast edges 40 GS s on one channel on the 2 5 GHz and 3 5 GHz models Option 2SR to double the maximum real time sample rate for the 500 MHz and 1 GHz models High bandwidth up to 3 5 GHz matched across 2 3 or 4 channels and enabled by Tektronix proprietary DSP enhancement The user selec table DSP filter on each channel provides magnitude and phase correction plus extension to 3 5 GHz for more accurate signal fidelity for complex measurements The DSP filter on each channel can also be switched off to take advantage of true 2 6 GHz analog bandwidth for applications needed the highest available raw data capture The DPOZO00 Series oscilloscopes include as apstandard feature a series of user selectable bandwidth limit filters These filters preserve the instrument s bandwidth rell off character istics flatness an
30. ith over 1400 combinations to address virtually any triggering situation Small footprint and light weight 12 1 largest XGA touch screen display in the industry Communications mask testing Clock recovery from serial data streams 64 bit NRZ serial pattern trigger for isolation of pattern dependent effects up to 1 25 Gb s NRZ serial test pattern triggering Low speed serial protocol triggering 12C SPI RS 232 CAN Technology specific software solutions provide built in domain expertise for Ethernet USB 2 0 compliance testing jitter timing eye diagram power DDR memory bus analysis CAN and LIN network design OpenChoice software with Microsoft Windows XP OS enables built in networking and extended analysis Applications Signal integrity jitter and timing analysis Verification debug and characteriza tion of sophisticated designs Debugging and compliance testing of serial data streams for telecom and datacom industry standards Low speed serial bus design I2C SPI CAN LIN RS 232 Investigation of transient phenomena Power measurements and analysis Spectral analysis Tektronix S Digital Phosphor Oscilloscopes DPO7000 Series Zoom in on four areas of interest simultaneously to compare them Optional up to 200 million total data points on the 500 MHz and 1 GHz models Easily manage this deep record length provide detailed comparison and analysis of multiple waveform segments w
31. ith the MultiView Zoom feature Automatically scroll through deep records visually or create a math expression to instantly highlight differences Highest performance probing solutions for differential and single ended voltage signals as well as current measurement because accurate design verification depends on high bandwidth access to critical signals and high fidelity signal capture Unmatched Versatility Get the Most of Your Oscilloscope by Fully Controlling its Waveform Acquisition and Display Parameters You have the choice of three horizontal time base modes of operations If you are simply doing signal exploration and want to interact with a lively signal you will use the Automatic or interactive default mode that provides you with the liveliest display update rate If you want a precise measurement and the highest real time sample rate that will give you the most measurement accuracy then the Constant Sample Rate mode is for you It will maintain the highest sample rate and provide the best real time resolution The last mode is called the Manual mode because it ensures direct and independent control of the sample rate and record length Tektronix Active probes achieve high speed signal acquisition and measurement fidelity 3 modes of operation of the horizontal time base Withethe MyScope Feature Create Your Own Control Windows With Only the Controls Features and Capabilities that You Gare About
32. iv to 500 mV div 10 605 mV div to 995 mV div 15 V to A Divisions 1 V div to 5 V div 100 9 05 V div to 10 V div 1504 to 10 Divisions Offset Accuracy 1 mV div to 9 95 mV div 0 2 offset value position 0 1 div 1 5 mV 1 mV div to 99 5 mV div 0 35 offset value position 0 1 div 1 5 mV 100 mV div to 1 V div 0 35 offset value position 0 1 div 15 mV 1 01 V div to 10 V div 0 25 offset value position 0 1 div 150 mV Delay between any two channels typical lt 100 ps 50 Q DCGoupling and equal V div at or above 10 mV div Channel to channel Isolation gt 100 1 at lt 100 MHz Any Two Channels at Equal Vertical Scale Settings typical gt 30 1 between 100 MHz and 2 5 GHz gt 20 1 between 2 5 and 3 5 GHz 1 3 GHz for sine wave of more than 4 div amplitude typically Time Base System DPO7054 DPO7104 DPO7254 DPO7354 Time Base Range 100 ps div to 1000 s div 50 ps div to 1000 s div 20 ps div to 1000 s div with Opt 2SR 00 ps div to 1000 s div 20 ps div to 1000 s div Time Resolution in ET IT mode 1 ps 900 fs 200 fs with Opt 2SR 900 fs 200 fs Time Base Delay Time Range ons to 250 s Channel to channel Deskew Range 75 ns Delta Time Measurement Accuracy 0 06 sample rate 2 5 ppm x Reading RMS Trigger Jitter RMS 1 5 PSpys typical with enhanced triggering OFF lt 100 fS with enhanced triggering ON Jitter Noise Floor lt 1 PSpyg lt 2 ps peak for record duration lt 10 us typical lt 2 9 PS
33. nformation Tektronix maintains a comprehensive constantly expanding collection of application notes technical briefs and other resources to help engineers working on the cutting edge of technology Please visit www tektronix com CE x g Copyright 2008 Tektronix All rights reserved Tektronix products are covered by U S and foreign patents issued and pending Information in this publication supersedes that in all previously published material Specification and price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tektronix Inc All other trade names referenced are the service marks trademarks or registered trademarks of their respective companies 10 08 HB WOW Product s are manufactured in ISO registered facilities 4MW 19046 12 Tektronix P
34. ouch screen shallow menu struc tures intuitive graphical icons knob per channel vertical controls support for right mouse clicks mouse wheel improvements saving of waveforms and measurements available in Preview mode Export Save Recall menu improvements Interoperability with Logic Analyzers for Digital Design and Debug Tektronix Integrated View iView data display enables digital designers to solve signal integrity challenges and effectively debug and verify their systems more quickly and easily This integration allows designers to view time correlated digital and analog data in the same display window and isolate the analog characteristics of the digital signals that are causing systems fail ures No user calibration is required And once set up the iView feature is completely automated How does 12 1 display compare to the display size of other oscilloscopes More Insight into Your Complex Electrical Design for Characterization and Compliance Testing Such as a simple math expression waveform mask testing a pass fail compliance test event searching event marking or a custom application that you develop yourself the DPO7000 Series Oscilloscopes offer the industry s most comprehensive set of analysis and compliance tools A Wide Range of Built in Advanced Waveform Analysis Tools Waveform cursors make it easy to measure trace to trace timing charac teristics while cursors that link between
35. pyg for record duration lt 30 ms lt 65 parts trillion for record durations lt 10 s Time Base Accuracy 8 9 Boome Aging lt 1 pom per year S 10 DPO7000 Series www tektronix com oscilloscopes Digital Phosphor Oscilloscopes DPO7000 Series Acquisition System DPO7054 DPO7104 DPO7254 DPO7354 Real time Sample Rates 1 channel max 10 GS s 20 GS s 40 GS s with Opt 2SR 20 GS s 40 GS s 2 channels max Gols 10 GS s 20 GS s with Opt 2SR 10 GS s 20 GS s 3 4 channels max 2 0 GS S 5 GS s 10 GS s with Opt 2SR 5 GS s 10 GS s Equivalent Time Sample Rate max 4 TS s for repetitive signals Maximum Record Length per Channel with Standard Configuration 40 M 1 CH 20 M 2 CH 10 M 4 CH with Record Length Opt 2RL 80 M 1 CH 40 M 2 CH 20 M 4 CH with Record Length Opt 5RL 200 M 1 CH 100 M 2 CH 50 M 4 CH with Record Length Opt 10RL 400 M 1 CH 200 M 2 CH 100 M 4 CH Maximum Duration at Highest Real Time Resolution 1 CH DPO7054 DPO7104 DPO7254 DPO07354 Resolution 100 ps 10 GS s 50 ps 20 GS s O 225 ps 40 GS s with Opt 2SR 50 ps 20 GS s 25 ps 40 GS s Max Duration with Standard 4 ms 2 mS 1 ms Record Length and Sample Rate with Opt 2SR 2 mS 1 ms Max Duration with Opt 2RL 8 ms 4 ms 2 ms with Opt 25R 4 ms 2 mS Max Duration with Opt 5RL 20 ms 1Q ms OMS with Opt 2SR 10 ms 5 ms Max Duration with Opt 10RL gt 10 ms Acquisition Modes DPO7054
36. r on width of positive or negative pulse either within or out of selectable time limits down to 225 ps Runt Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again Event can be time or logic qualified Timeout Trigger on an event which remains high low or either for a specified time period Selectable from 300 ps Transition Trigger on pulse edge rates that are faster or slower than specified Slope may be posi tive negative or either Setup Hold Trigger on violations of both setup time and hold time between clock and data present on any two input channels Pattern Trigger when pattern goes false or stays true for specified period of time Pattern AND or NAND NOR specified for four input channels defined as high low or don t care State Any logical pattern of channels 1 2 3 clocked by edge on channel 4 Trigger on rising or falling clock edge Window Trigger on an event that enters or exits a window defined by two user adjustable thresh olds Event can be time or logic qualified Trigger Delay by Time 5 ns to 250 s Trigger Delay by Events 1 to 10 000 000 events Comm Provided as part of Opt MTM Support for AMI HDB3 BnZS CMI MLT3 and NRZ encoded signals 12C SPI and RS 232 Protocol trigger on DP07054 DPO7154 DPO7254 or DPO7354 CAN Protocol trigger on DP07054 DPO7154 DPO7254 or DPO
37. rates a Waveform Database pixmap from a sample wave form Sample count can be defined Digital Phosphor Oscilloscopes DPO7000 Series Display Characteristics Display Type Liquid crystal active matrix color display Display Size Diagonal 307 3 mm 12 1 in Display Resolution XGA 1240 horizontal x 768 vertical pixels Waveform Styles Vectors Dots Variable Persistence Infinite Persistence Color Palettes Normal Green Gray Temperature Spectral and User defined Display Format YT XY Computer System and Peripherals Operating System Windows XP CPU Intel Pentium 4 3 4 GHz processor PC System Memory 2 GB Hard Disk Drive Rear panel removable hard disk drive 80 GB capacity CD R W Drive Front panel CD R W drive with CD ereation software application DVD Drive Read only Mouse Optical wheel mouse USB interface Printer optional Thermal printer fits in accessories pouch provided with instrument Keyboard Order 119 7083 00 for small keyboard fits in pouch USB interface and hub Input Output Ports Front Panel Probe Compensator Output Front panel pins Amplitude 1 V 20 into a 50 Q load 500 mV from base to top into a 50 Q load frequency 1 kHz 5 Recovered Clock for DP07254 or DPO7354 only BNC connector lt 1 25 Gb s Output swing gt 130 mVp p into 50 Requires option to enable Recovered Data for DP07254 or DP0735
38. simple turn of the intensity knob clearly see the fre quency of occurrence Easy Connectivity Built in USB port at the front for easy access to save your work on a memory stick Most standard input output ports available on the side of the instrument Scale 250VRMS h 9 A Wide Range of Built in Advanced Analysis Tools Linked XY and YT cursors 53 automatic measurements Waveform boundary tolerance testing Many math functions some advanced like FFT or Filtering iwienaitw Single Clear i FastAog Mit dE n d Position il Mullivire Edge Advanced Loom Ci l Source r An j ERY Limi PEL pce Cursors RAweniuti b E s 5 lt pi Te ey bE Lawl Mee 4a gt Scale Siope Mordi Phi TET Ney on p a SEE Se ee Ch 1 Ch2 Ch3 10 For Insight into Your Low speed Serial Designs Serial Protocol Triggering for 12C SPI CAN plus a complete CAN and LIN timing and protocol analysis software package Digital Phosphor Oscilloscopes DPO7000 Series I Wi Wn I n i i Hii TH Mm Power measurement Accelerate the research of multiple events in an acquired waveform 11 For Insight into Ge 10 12 Tir 2 10 9 Compliance testing for many serial standards like USB and Ethernet 12 A Breadth of Optional Software Packages for Expanded Wave form Analysis
39. th the instrument DPO7OOO Series e www tektronix com oscilloscopes Digital Phosphor Oscilloscopes DPO7000 Series Jitter Timing and Eye Diagram Analysis Jitter Timing and Eye Diagram Analysis Jitter Timing and Eye Diagram Analysis Opt DJA Tight timing margins associated with today s serial buses demand stable low jitter designs DPOJET extends the oscillo scope capability by making itter timing and eye diagram measurements over contiguous clock and data cycles in a single shot real time acquisition With multiple measurements and a variety of analysis tools including spectral and trend plots DPOJET quickly shows system timing under variable condi tions It also provides Rj Dj on signals without a repeating pattern and without requiring a fixed pattern or length You can get insight into the signal charac teristics like SSC profile using the analysis features and perform pass fail testing using eye diagram masks and limit files for testing against statistical limits using the compliance features This tool is available for the DPO7000 Series as Opt DJA and Opt DJE Advanced Event Search and Mark Opt ASM Event Search and Mark will relieve the user from the tedious task of examining data by highlighting important events skipping the unim portant ones and enhancing the comprehension of event relationships Accelerating the research of specific events in an acquired waveform You can navig
40. the fast embedded bus wave form data can be moved directly from acquisition to analysis applications on the Windows desktop at much faster speeds than conventional GPIB trans fers Tektronix implementation of industry standard protocols such as TekVISA interface and Activex controls are included for using and enhancing Windows applications for data analysis and documentation IVl COM instrument drivers are included to enable easy communication with the oscilloscope using GPIB serial data and LAN connections from programs running on the instrument or an external PC Or use the Software Developer s Kit SDK to help create Digital Phosphor Oscilloscopes DPO7000 Series Maximize the probability of capturing elusive glitches and other infrequent events with FastAcq acquisition mode custom software to automate multistep processes in waveform collection and analysis with Visual BASIC C C MATLAB LabVIEW LabWindows CVI and other common Application Development Environments ADE Integration of the oscilloscope with external PCs and non Windows hosts is also supported by the DPO7000 Series software solutions In addition the OpenChoice architecture provides a comprehensive software infrastructure for faster more versatile operations Data transfer programs such as the Excel or Word toolbar are used to simplify analysis and documentation on the Windows desktop or on an external PC Accelerate the Debug of
41. ture lower risk and off balance sheet accounting Both second user and rental improve the key business measure of Return On Capital Employed We are based near Heathrow Airport in the UK from where we supply test equipment worldwide Our facility incorporates Sales Support Admin Logistics and our own in house Lab All products supplied by Test Equipment Solutions include No quibble parts amp labour warranty we provide transport for UK mainland addresses Free loan equipment during warranty repair if available Full electrical mechanical and safety refurbishment in our in house Lab Certificate of Conformance calibration available on request Manuals and accessories required for normal operation Free insured delivery to your UK mainland address sales Support from our team of seasoned Test amp Measurement engineers ISO9001 quality assurance Test equipment Solutions Ltd Unit 8 Elder Way Waterside Drive Langley Berkshire SL3 6EP T 44 0 1753 596000 F 44 0 1753 596001 Email info TestEquipmentHQ com Web www TestEquipmentHQ com Digital Phosphor Oscilloscopes DPO7000 Series Unmatched Performance for Greater Insight Into Your Design to Get Your Work Done Faster The DPO7000 Series are the new generation of real time digital phosphor oscilloscopes and are the industry s best solution to the challenging signal integrity issues faced by designers veri fying characteriz