Home
SI005 LED Messaging Sign Operation, Installation and Service
Contents
1. Option Default Description GALEDBZ ON Turns audible annunciation buzzer on GALEDBZTY 2 Sets buzzer to three beeps GALEDSPEED 3 Sets scroll speed to setting 3 medium GALEDMESG TT default TekTone Communications for today and tomorrow GALEDMGCT AU Messages are stored in order of newest first holds 24 messages before overwriting oldest message GALEDRESCM ON Allows user to send reset text message command GALEDTM OFF Turns time display off GALEDDT OFF Turns date display off GALEDBZTM 001 Sets buzzer time to 1 second length GALEDCLRDY 270 Sets the timeout for each message at 270 seconds this is the time that will elapse before the message will clear GALEDTMSM 0 Turns off the time stamp for a message GALEDMGTM 003 Sets the holding time for a non scrolling message to 3 seconds This is the time that will elapse before going to the next message This is only applicable to messages that are short enough to not scroll GALEDDTMD 1 Sets date format to MMMM DD YY GALEDLANG ENG Sets language for date display to English GALEDTMD 2 Sets amount of time to 2 seconds to display the date and time after all the messages have been scrolled GALEDSHTM 002 Sets the hold time for the time display after the messages to 2 seconds IL891 SI005 LED Messaging Sign Rev 1 Me Sete Jon Write Read Frequenoy Range Of Frequency 199MHz 12 51 y Frequency Of Pager 45755 OH
2. DD MMM YY 1 MMMM DD YY 2 MM DD YY 3 DD MM YY 4 MM DD YY 5 DD MM YY 6 MM DD YY 7 DD MM YY 8 MM DD YY 9 DD MM YY Time Setting GALEDTIME HHmmss HH hour from 00 to 23 mm minute from 00 to 59 SS second from 00 to 59 Language to dis GALEDLANG XXX ENG English FRA France play Date Display Mode GALEDTMD X 1 display time after every message 2 display time after for the Time all messages displayed Hold time to dis GALEDSHTM XXX Allows you to choose from 001 to 999 seconds play each mes sage Length time for GALEDBZTM XXX Allows you to choose from 001 to 999 seconds Buzzer Auto Clear delay GALEDCLRDY XXX Following options allow you to have your messages cleared time for all mes automatically after the time chosen 000 auto clear dis sages able delay time 001 to 999 seconds each message will auto clear after delay time is timed out Time Stamp For GALEDTMSM X To display the time stamp format in the front or after each mat message 0 Off 1 time stamp in the head of message 2 time stamp in the end of message time stamp format is HH MM 24 hours time format Non Scroll Hold GALEDMGTM XXX Only for short messages less than the characters the dis time play holds from 001 to 999 seconds this feature only ac tive when the message length less then LED sign character length the default time is 3 seconds Table A 1 Programming Commands Complete List
3. 12 IL891 SI005 LED Messaging Sign Rev 1 Appendix B A Word about ESD Electrostatic Discharge What Is It Static electricity is a result of triboelectric charging of two dissimilar non conductive materials that are rubbed together such as rubbing your feet on a carpet on a cold winter day or in a dry climate The resulting charge is detected when you reach out to touch a doorknob or some other metallic object The resulting discharge may only be startling or in severe cases it may even be painful The actual electrical charge is dependant on the materials being rubbed together humidity the rate of separation and other factors What Can It Do While this effect may be disturbing to humans the effect on electronic equipment is often more serious ranging from operational disruption to actual component damage These effects result from the high voltages that may be developed The simple act of walking across a carpet may develop as much as 30 000 volts and changing a bed sheet may create a charge of 100 000 volts or more Such voltages readily cause arcing the spark that can be observed when you grab a doorknob after walking across a carpet etc The arcing is evidence of the discharge path Due to the high voltage involved the discharge current can jump to any nearby metallic or non metallic object If the discharge is to or through an electronic device such as the nurse call system the operation of the device may be affe
4. SI005 Sign s capabilities are limited by the system s capabilities An NC369 or NC365A T Paging Transmitter is used to send a signal from the nurse call system to the sign Therefore if the system does not already include radio pocket paging purchase an NC369 Paging Transmitter along with the sign Your TekTone SIOO5 LED Sign has been pre programmed at the factory and usually will not require reprogramming Emerg 0101 Figure 1 1 SIOO5 LED Messaging Sign IL891 SI005 LED Messaging Sign Rev 1 Chapter 2 General TekTone Sound Figure 2 1 SIOO5 LED Messaging Sign 2 1 What is in the box The following are included in your SI005 package e LED Sign e Mounting hardware e LS005 Software CD and Serial Cable if purchased 2 2 Features e Alpha LED Display e Display memory 163 200 bytes e Message size 37 characters e Wireless data input e Size 28 L X 6 3 4 H e Weight 8 4 lbs e Character Height Capital Letters 3 75 Lowercase 2 25 IL891 SI005 LED Messaging Sign Rev 1 Chapter 3 Installation 3 1 Mounting As shown in figure hardware is supplied to mount your LED sign Be sure to use proper anchors to attach the brackets to the mounting surface as the sign weighs over 8 pounds Figure 3 1 Mounting the SI005 LED Messaging Sign 3 2 Programming Your TekTone SIOO5 LED Sign has been pre programmed at the factory and normally will not require repro gramming The
5. full listing found in the Appendix Table 3 3 Optional LS005 Programming Software As described previously the sign comes with a pre programmed CAP Code It may be necessary to change it in the future due to some conflict with a Radio Pocket Pager system or you may desire more than one CAP Code per sign Use LS005 to make these changes The SIOO5 LED Sign can be assigned any Pager ID up to 9999999 and each sign can be assigned up to six Pager IDs For Signs used with the Tek CARE400 nurse call system or the Tek CARE500 wireless emergency call system choose a CAP Code between 000 and 999 Use this formula to convert the desired CAP Code to its corresponding Pager ID Pager ID Sign s CAP code 8 10000 See CAP Code to Sign Pager ID Conversion Table for CAP codes most commonly used with TekTone pagers Figure A 3 3 3 1 LS005 Software Direct Connect 1 Connect DB9 serial cable from the serial port on the PC to the serial port on the SI005 Boot up the PC and power on the SI005 Insert LSOO5 CD and double click Ledsignprm 2 3 4 The programming window will load Figure 3 2 5 Click on the Read button and confirm that the settings are read from the SI005 6 In order to commit any changes to the SI005 click on the Write button and confirm that the settings are written to the SI005 IL891 SI005 LED Messaging Sign Rev 1 Table 3 1 Programming Commands Factory Default
6. most common generation of ESD in hospitals is due to changing linen on hospital beds while the patient call cord or pillow speaker is still connected to the nurse call system The following precautions will help Remove the call cord or pillow speaker from the bed before changing the linen It will be necessary for the nursing staff to discharge themselves by contacting a grounded metal object before placing the call cord or pillow speaker back on the bed otherwise a spark will jump to the nurse call equipment causing the very damage they are trying to avoid To avoid a shock while discharging static electricity on the body hold a metal object such as a key and use that object to contact the grounded surface This information is provided to make you aware of ESD problems so that precautions may be taken to avoid damage and disruption of system operation 14
7. to send each capcode and function will locate its message slot messages would come in order as sent for each slot AU Auto you also have 24 message slots but does not keep each message for its location this means that messages come in as they are sent by order of the time the message is sent example the 25th message would replace the first message sent 26th message would display the second message sent and so on Clear by Reset command GALEDRESCM ON or OFF To reset and clear a specific message ON Allows you to clear a specific message by using typing header or trailer with reset word then the same message will be cleared a the header format is reset your message b the trailer format is your message reset The reset will recognize the message in the lower or upper caps Part 1 continued on next page 11 IL891 SI005 LED Messaging Sign Rev 1 Part 2 continued from previous page Features Command Parameters Description Time display GALEDTM ON or OFF ON Time display enable OFF Time display disable On Off Time Date GALEDDT ON or OFF To turn Date display ON or OFF On Off Setting the Date GALEDDATE YYMMDD YY year from 0 to 99 MM month from 1 to 12 DD day from 1 to 31 Format to dis GALEDDTMD X O to 9 means different formats to display the date 0 play the Date
8. Code ID ID ID ID 1D Figure A 3 Cap Code to Sign Pager ID Conversion Table 10 IL891 SI005 LED Messaging Sign A 2 Other Tables Rev 1 Features Command Parameters Description Delete All Mes sages GALEDDELALL This command will clear all messages displayed then it will show the default message on the LED sign Buzzer On Off GALEDBZ ON or OFF Allows you to turn the buzzer on or off Buzzer music type GALEDBZTY X Allows you to change the tone of the beep and change Music types from 0 to 9 Scroll control Speed GALEDSPEED X Allows you to change the speed of message scroll from X 1 slowest to 5 fastest note that scroll feature only works if the number of the characters are more than the numbers the LED holds on a single screen otherwise the message would stay still Default message GALEDMESG Automatically sends the pre stored 50 character default message to the sign Apollo LED signs moving display Message Counter GALEDMGCT This function gives you 3 options 01 Allows you to only use one message slot for any capcode and function bit this means that you have 6 capcodes and 4 function bits per each capcode which gives you the total of 24 message slots in this option each message should be sent to that specific message slot to be able to replace that particular message the other slots would remain unchanged 24 Allows you
9. TekTone SOUND amp SLEG Communications for today and tomorrow SI005 LED Messaging Sign Operation Installation and Service Manual TekTone Sound amp Signal Mfg Inc Website Email tektone tektone net TT D Address Par Franklin NC 28734 United States Phone 828 524 9967 800 327 8466 Toll Free Tech Support Option 2 Sales Option 3 Fax 828 524 9968 IL891 March 2010 Rev 1 oom ality Syste Oo y gt Abstract The SIOO5 LED Messaging Sign can be used to provide ancillary annunciation of calls placed on the Tek CARE400 Nurse Call and Tek CARE500 Emergency Call systems Annunciation is visual and can be ac companied by an optional tone The SIOO5 acts like a pager it receives a wireless transmission and then subsequently clears the call after a programmed time If the nurse call system has been set up for manual text messaging the SI005 can provide this function ality as well The SI005 sign is provided with default settings changes are made by sending a manual text message to the sign The SIOO5 CAP Code is pre programmed at the factory For reprogramming CAP Codes software LS005 is available separately and runs on a laptop computer The software package may be used for multiple signs IL891 SI005 LED Messaging Sign Rev 1 Operation Installation and Service Manual Copyright 2003 2010 TekTone Sound 8 Signal Mfg Inc All rights reserved No part of this pu
10. Z Baud Rate 512 by Signal Polarity Normal s Language English y Sequential Lock 0 Sec Capcode Decimal Address Capcode 1 123454 BON Fun Bit A Alpha B Alpha C Alpha D Alpha 7 Capcode 2 123456 ON Fun Bit A Alpha B Alpha C Alpha D Alpha Capcode 3 123454 IN Fun Bit A Alpha B Alpha C Alpha p Alpha gt Capcode 4 1254504 ON Fun Bit A Alpha B Alpha C Alpha D Alpha Capcode 5 123456 ON Fun Bit A Alpha B Alpha c Alpha p Alpha x Capcode 6 123456 ON Fun Bit A Alpha B Alpha c Alpha D Alpha S Ready Figure 3 2 SI005 LED Messaging Sign Program Screen 7 Unplug the serial cable from the PC and the S1005 8 Cycle power to the SIOO5 All changes should now be committed 3 4 Programming Notes By default the frequency of the SI005 will be 457550000 Hz and the baud rate will be 512 However with the programming software LS005 these values can be changed Up to six Pager IDs can also be added for the SI005 The pager type can also be changed however it is recommended that this setting remain on Alpha 3 5 System Testing To test the SIOO5 LED Messaging sign 1 Place a call on the system 2 Verify that the call is received by the SI005 and clears after the preset time period IL891 SI005 LED Messaging Sign Rev 1 3 If using manual text messaging use the Tek CARE400 or Tek CARE500 s message editor and send a specific message 4 Verify the test message is receive
11. blication may be copied without the express written permission of TekTone Sound amp Signal Mfg Inc The content of this manual is furnished for informational use only is subject to change without notice and should not be construed as a commitment by TekTone Sound amp Signal Mfg Inc TekTone Sound amp Signal Mfg Inc assumes no responsibility or liability for any errors or inaccuracies that may appear in this documentation TekTone the TekTone logo Tek Bridge Tek Call Tek Care Tek Check In Tek Com Tek Digicare Tek Door Tek Entry III Tek Guard Tek Micro Tek Micro II Tek MMARS II TekNIOS TekNIOS II Tek Paging Tek Phone Tek Safe Tek Select II Tek Sentry Tek Sound Tek Status Tek Trio and Tek View are either reg istered trademarks or trademarks of TekTone Sound amp Signal Mfg Inc in the United States and or other countries All other trademarks are the property of their respective owners TekTone Sound amp Signal Mfg Inc 277 Industrial Park Road Franklin North Carolina 28734 USA IL891 SI005 LED Messaging Sign Rev 1 About This Manual This manual is designed to assist with installation of this TekTone product Each component of the system is described with step by step instructions to facilitate hardware installation and software configuration A 1 Important Please take all precautions against high voltage shock This is a mains powered unit A 1 Important Please use proper mo
12. cted If the discharge current passes through internal components these components may be damaged or their operation degraded What Can We Do About It The manufacturer of the nurse call equipment has already taken steps to protect the equipment from elec trostatic discharge ESD effects Our peripheral equipment has been tested and listed by UL to withstand discharges of up to 30K volts However since the cause is not in the equipment but in the environment further measures are required of the installer and the user to achieve complete protection What The Installer Can Do In humid climates or in places where the relative humidity is kept at 65 or greater there will likely be few problems with ESD Where problems may occur the following measures can be taken e Ground all exposed metal surfaces Grounding should be to a 16 gauge or larger conductor e Install nurse call system wiring in metal conduit This conduit may be used to ground panels 13 IL891 SI005 LED Messaging Sign Rev 1 e Use shielded cable for nurse call system station to station wiring The use of open conductors invites inductive coupling of discharge currents which can cause the same problems as direct discharge cur rents e Ground your body before handling system components This can be done by using a wrist strap or simply by contacting a grounded metal surface Use caution to avoid hazardous voltages while grounded What The User Can Do The
13. d by the SI005 and clears after the preset time period IL891 SI005 LED Messaging Sign Rev 1 Chapter 4 User Manual 4 1 Factory Pre Programming Your TekTone SIOO5 LED Messaging Sign has been pre programmed at the factory and normally will not require reprogramming Unless otherwise programmed the SI005 will automatically receive text messages from the paging trans mitter connected to the nurse call system Your system integrator will have programmed your system accord ing to your instructions Because the nurse call system provides manual text messaging to a radio pocket pager system this ability also applies to the messaging sign 4 2 Manual Text Messaging The SI005 Sign should have been assigned a CAP Code just like a radio pager To send a manual text message to the LED sign follow these steps 1 Move through your menus to the nurse call system text message screen 2 Select the CAP Code of the SI005 sign from the group of Staff Areas Devices 3 Enter a default message or type a new message 4 Click on SEND or press the ENTER key 5 The call will begin scrolling on the SI005 LED Messaging Sign for the preset time period IL891 SI005 LED Messaging Sign Appendix A Appendix A 1 Other Figures fay ake lt Figure A 1 9 pin Straight Serial Cable Figure A 2 SIOO5 LED Messaging Sign Software CD Rev 1 IL891 SI005 LED Messaging Sign Rev 1 CAP Pager Pager Pager Pager Pager
14. sign number or CAP Code is programmed in and labeled for you It will be important to be IL891 SI005 LED Messaging Sign Rev 1 sure the sign number does not conflict with existing pocket pager numbers if pocket paging is installed on the system Please see your System Installation Manual on adding a Radio Pocket Pager Follow that procedure to add your SIOO5 LED Message Sign to a TekTone Tek CARE400 nurse call system or a Tek CARE500 Wireless Emergency Call System The manual numbers are listed below and available at www tektone com 3 2 1 List of System Installation Manuals e NC369 Transmitter IL888 e NC365A T Transmitter IL671 e Tek CARE400 Nurse Call System IL843 e Tek CARE500 Wireless Emergency Call System IL815 IL880 IL881 3 2 2 Programming Programming Commands Sent Via Manual Text Messaging Programming commands can be sent by manual text message see Send a Manual Text Message section of your system Installation Manual For example sending the desired command with the selected value i e GALEDBZ OFF as a text message to the sign would turn the audible buzzer tone off at the message sign so that any subsequent incoming message would no longer activate an audible annunciation The Programming Commands Factory Default table Table 3 1 shows a list of programming commands that are preset at the factory for the SIOO5 In the table each command includes a default and general description of what it actually does There is a
15. unting techniques to accommodate a fixture that exceeds 8 pounds iii IL891 SI005 LED Messaging Sign Rev 1 Contents 1 Theory of Operation 1 2 General 2 21 Whatisin the box 102 Stk ad Per see sake sg 2 2 2 Features ss vasse RAGS Frk Ek res SE S TE GEA AGS SE SEE kle ES 2 3 Installation 3 3 1 Mounting evo ses sog KG 6 sk k kN EEE MEG EG EE EE ET a UR aa 3 3 2 Programming es sake ed ae en BS aR Er PE p p p 3 3 2 1 List of System Installation Manuals 2 aar o ooo e 4 3 2 2 Programming gt sses es saw o n SA RR ee EOE SEEN SG 4 3 3 Optional LS005 Programming Software o o e eee 4 3 3 1 18005 Software Direct Connect o ee ee 4 3 4 Programming Notes have kler kake eee ra 6 3 5 System Testing s oca a a a a ee oa 6 4 User Manual 8 4 1 Factory Pre Programming 222 see eee eee eee krav 8 4 2 Manual Text Messaging 1 2 ee 8 A Appendix 9 Al Other Figures 2 cra eo oe a SET me Oe eae dpa hae KAT ee 9 A2 Other Tables coc oo morsa eee a MG 11 B A Word about ESD Electrostatic Discharge 13 iv IL891 SI005 LED Messaging Sign Rev 1 Chapter 1 Theory of Operation Similar to TekTone s Radio Pocket Paging equipment the SIOO5 LED Sign uses CAP Codes to distinguish between signs This allows calls to be vectored depending on assignments i e groups or zones Please note that the