Home

SPARC Enterprise M3000/M4000/M5000/M8000/M9000

image

Contents

1. deletecodlicense 8 setcod 8 command m At this time the e 1 P options of the snapshot 8 command are not supported m An XSCF user account user name cannot match an LDAP user name and an XSCF user account number UID cannot match an LDAP UID number m Incase that any failure occurred on a system board and failed to read the FRU information of system board XSCF regards the system board as a COD board The showboards va command displays the COD status as y In this case replace the failed system board XCP 1110 Issues and Workarounds For known XCP issues and possible workarounds in XCP 1110 see Known Issues and Workarounds in XCP 1110 on page 15 For fixed XCP issues in XCP 1110 see XCP Issues Fixed in XCP 1110 on page 18 Chapter 2 XCP 1110 and XCP 1110 related Information 11 Updating to XCP 1110 To update your XCP to XCP 1110 please pay attention to the following points depending on your current XCP version You can upgrade to XCP 1110 from XCP version 1050 or later Refer to the SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers XSCF User s Guide for instructions Resetting the XSCF Firmware After updating the XCP firmware to 1110 do not fail to reset the XSCF by using the rebootxscf 8 command Updating from a Version Earlier Than XCP 1050 M8000 M9000 Servers m You cannot update to XCP 1110 directly If you are currently running a version earlier than XCP 1050 you must first
2. additional PCI X card is installed or a PCI X card is replaced by using PCI hot plug been fixed in patch 120011 08 Workaround Do not insert a different type of PCI X card on the same PCI slot by using PCI hot plug Chapter 3 Information About Software 63 TABLE 3 10 Oracle Solaris OS Issues Fixed in Oracle Solaris 10 8 07 Continued M4000 M8000 CR ID M3000 M5000 M9000 Description Workaround 6509337 O O s10s_u3 wanboot fails The server No workaround is available returned 416 Requested Range Not Satisfiable 6510861 O O When Dual Channel Ultra320 SCSI For Oracle Solaris 10 11 06 this has Card SEOX7SC2F SEOX7SC2X is been fixed in patch 120011 08 mounted correctable errors CE occur and system may panic Workaround Add the following entry to the etc system file and then reboot the system set pcie pcie aer ce mask 0x31c1 6520990 O O Domain may cause a panic when For Oracle Solaris 10 11 06 this has deleteboard 8 command for kernel been fixed in patch 120011 08 board by using Dynamic Reconfiguration DR Workaround To mask this error add the following entry to the etc system file set drmach fmem timeout 30 6527781 O The cfgadm command fails while For Oracle Solaris 10 11 06 this has moving the DVD Tape drive unit been fixed in patch 125081 06 between two domains No workaround is available To reconfigure DVD Tape drive unit execute reboot r from the domain exhibiting th
3. you can log in but then when you execute the XSCF Shell or operate the XSCF Web Permission denied occurs RTIF1 O O On the XSCF Web when you use None available at this time 070914 007 Internet Explorer and select Log Archives the Status of Log Archiving screen doesn t show the status information RTIF1 O O On the XSCF Web when you select None available at this time 070914 008 POP or SMTP auth on the SMTP screen to enter Password the input value doesn t appear as RTIF1 O O On the XSCF Web when selected POP None available at this time 070914 009 or SMTP auth on the SMTP screen the setting can be done while the input field remains blank And despite the setting done the past setting data appears RTIF1 O O On the XSCF Web on the SNMPv3 When you set the SNMP User with 16 070914 010 Security Settings screen when you digits or more use the showsnmpusm 8 select Add User or Copy User of the SNMP User Based Security Model USM the Create or Copy User screen appears as a pop up On this screen when you set the SNMP User with 16 digits or more it will be registered correctly but the web browser screen displays up to 15 digits command Chapter 3 Information About Software 25 TABLE 3 3 XCP Issues Fixed in Releases Earlier Than XCP 1110 Continued ID M4000 M8000 M3000 M5000 M9000 Description Workaround RTIF1 070914 011 RTIF1 070914 012 RTI
4. AC OFF ON To turn on the system power that you turned off wait at least 30 seconds before power on M3000 server Check that XSCF is started If not started stop the domain and then execute the system power off on AC OFF ON To turn on the system power that you turned off wait at least 30 seconds before power on RTIF1 O O When connected to telnet the login or Disconnect the telnet session and try 070802 001 the password prompt doesn t appear again RTIF1 O O Using the XSCF Web when you To specify the value which exceeds the 070823 001 selected SSH on the snapshot screen maximum number of character input the maximum number of character for the XSCF Web use XSCF Shell input for Host Directory ID and Password doesn t correspond to the maximum number of character input on the XSCF Shell RTIF1 O O When you display the Logical tree on On the Menu select System Board 070823 002 the XSCF Web there may be multiple Configuration and refer to the domain displays of the same domain configuration from XSB Status All Or depending on the domain use the showboards 8 command to configuration refer to the domain configuration RTIF1 O O When you display the Logical tree on On the Menu select Device Status to 070823 003 the XSCF Web the hardware refer to the domain hardware configuration of CPU or memory which assigned to the domain appears differently from the actual domain configuration configuration Or use the showdevi
5. M3000 server Check that XSCF is started If not started stop the domain and then execute the system power off on AC OFF ON To turn on the system power that you turned off wait at least 30 seconds before power on Chapter 3 Information About Software 19 TABLE 3 3 XCP Issues Fixed in Releases Earlier Than XCP 1110 Continued M4000 M8000 ID M3000 M5000 M9000 Description Workaround RTIF1 O O The showdomainstatus a command Use the showboards command to 070418 010 shows domain status as Powered Off check the status of domain power but the showboards a command The showdomainstatus command shows the domain is testing takes a longer time to show the correct status RTIF1 O O Some commands that update Do not cancel set commands They 070418 011 configuration data take a relatively long appear to hang but eventually time to execute complete in about 30 seconds RTIF1 O O The fault memory block ue is An uncorrectable error exists in a 070418 012 encountered and reported periodically DIMM and the DIMM should be replaced RTIF1 O O When using the XSCF Web to importa Use the command getflashimage d 070418 020 firmware image if the image is to delete the corrupted image If corrupted for example if the browser necessary reboot the XSCF Unit then window is closed during import the use the flashupdate command again flashupdate command might later to clear the internal error report an internal error CR ID 653799
6. Workaround These messages can be safely ignored Chapter 3 Information About Software 59 TABLE 3 9 Oracle Solaris OS Issues Fixed in Oracle Solaris 10 5 08 Continued M4000 M8000 CR ID M3000 M5000 M9000 Description Workaround 6564934 O O Performing a DR deleteboard 8 For Oracle Solaris 10 8 07 this has been operation on a board which includes fixed in patch 127741 01 Permanent Memory when using the following adapters results in broken Workaround connections d Re configure the affected network e PCIe Qua port Gigabit Ethernet interfaces after the completion of the UTE Low Profile Adapter X4447A Z DR operation For basic network e PCle Dual 10 Gigabit Ethernet Fiber configuration procedures refer to the XFP Low Profile Adapter X1027A Z ifconf ig man page for more information 6568417 O O After a successful CPU DR For Oracle Solaris 10 8 07 or earlier deleteboard 8 operation the system this has been fixed in patch 127111 02 panics when the following adapters are Buse Workaround e PCIe o r Ethernet Add the following line to UTR Low Pro us A Apter OAA etc system and reboot the system e PCIe Dual 10 Gigabit Ethernet Fiber Set ip ip soft rings cnt 0 XFP Low Profile Adapter X1027A Z E 6571370 O O Use of the following adapters have been For Oracle Solaris 10 8 07 this has been observed to cause data corruptionin fixed in patch 127741 01 stress test under laboratory conditions PCI
7. correctly configured for the IPMP group and does not need any modification The IP addresses used in the example above should match what was previously used and what matches the etc hostname lt interface gt file Use the following operations to display all of the PCI slots 1 devfsadm at Oracle Solaris OS prompt 2 cfgadm Set the following to etc system and then reboot the domain set maxfastscan 0x2000 Reduce the amount of kernel memory that ZFS can allocate by setting the zfs_arc_max parameter in the etc system file The following example sets the maximum size to 512 Mbytes set zfs arc max 0x20000000 44 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 TABLE 3 4 Oracle Solaris OS Issues and Workarounds for All Supported Releases Continued M4000 M8000 CR ID M3000 M4000 M9000 Description Workaround 6529714 O O Warning messages occur while trying to No workaround is available configure more than four PCIe Quad port Gigabit Ethernet UTP Low Profile Adapter X4447A Z or PCIe Dual 10 Gigabit Ethernet Fiber XFP Low Profile Adapter X1027A Z into one I O Boat 6530753 O O Some of the PCI slots in the External Use one of the following operations to I O Expansion Unit PCI slots are not display all of the PCI slots displayed during a normal boot e boot r at open boot prompt operation e devfsadm C at Oracle Solaris OS prompt e cfgadm twice at Oracle Solaris OS
8. fujitsu com global contact computing sparce_index ht ml xiv SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 CHAPTER 1 Software Requirements This section contains the software requirements of SPARC Enterprise M3000 M4000 M5000 M8000 M9000 M3000 M4000 M5000 M8000 M9000 servers a XCP Oracle Solaris OS and Required Patches on page 1 Obtaining XCP and Oracle Solaris Patches on page 4 m Web Browser on page 4 XCP Oracle Solaris OS and Required Patches The supported XCP and Oracle Solaris Operating System Oracle Solaris OS depends on the processors being installed on the SPARC Enterprise M3000 M4000 M5000 M8000 M9000 servers This section lists supported XCP and Oracle Solaris OS and mandatory patches for the M3000 M4000 M5000 M8000 M9000 servers Note Apply the patches in the following order For the procedures of CPU upgrade including the patches see SPARC Enterprise M8000 M9000 Servers Service Manual TABLE 1 1 Supported XCP Oracle Solaris OS and Required Patches Server Processors XCP Oracle Solaris OS Required Patches M4000 M5000 SPARC64 VII 2 66 GHz M8000 M9000 SPARC64 VII 3 00 GHz 1100 or later Oracle Solaris 11 11 11 Oracle Solaris 10 8 11 Oracle Solaris 10 9 10 Oracle Solaris 10 10 09 Oracle Solaris 10 5 09 Oracle Solaris 10 10 08 Oracle Solaris 10 5 08 Oracle Solaris 10 8 07 No patches required No p
9. system power is controlled as follows TABLE 6 1 RCI and APCS Control with Mode Switch Function Mode Switch Locked Service RCI Remote power on power off op Remote power on power off op erations are enabled erations are disabled APCS Automatic power on power off Automatic power on is disabled operations are enabled but power off remains enabled To use the RCI function see the SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers RCI Build Procedure and the SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers RCI User s Guide 88 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 To use the APCS see the Enhanced Support Facility User s Guide for Machine Administration Automatic Power Control Function Supplement Edition Limitation for 1027A Z X1027A Z For PCIe Dual 10 Gigabit Ethernet Fiber XFP Low Profile Adapter 1027A Z X1027A Z these maximum limits apply No more than six cards per a domain m Do not use these cards in an External I O Expansion Unit Limitation for 4447A Z X4447A Z For PCIe Quad port Gigabit Ethernet UTP Low Profile Adapter 4447A Z X4447A Z these maximum limits apply No more than eight cards per a domain No more than four cards in an External I O Expansion Unit two per PCIe I O boat Patches for Emulex PCI Express PCIe Adapters The following Emulex PCle adapters require drivers supplied in patch 120222 26 m Sun Stora
10. update to an interim version of XCP between 1050 and 1070 inclusive before updating to XCP 1110 Refer to the product notes document for the interim version for instructions m Delete any accounts named admin Any accounts named admin must be deleted prior to updating to XCP 1050 or later This account name is reserved in XCP 1050 and later Use the deleteuser 8 command to delete the account Updating from a Version Earlier Than XCP 1070 M8000 M9000 Servers On a domain which has been in operation during the XCP update to 1110 when you perform Dynamic Reconfiguration DR to add or replace the SPARC64 VII processors you need to update the OpenBoot PROM firmware The OpenBoot PROM firmware is updated as you update the XCP and restart the domain For this reason it is strongly recommended to restart all the domains after you update the firmware to XCP 1110 regardless of whether you added or replaced the SPARC64 VII processors 12 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 CHAPTER 3 Information About Software This section describes the special instructions and the issues about the M3000 M4000 M5000 M8000 M9000 servers software Notes and Limitations on page 13 XCP Issues and Workarounds on page 14 Oracle Solaris OS Issues and Workarounds on page 42 Software Documentation Updates on page 66 Miscellaneous Information on page 67 Notes and Limitation
11. 125100 06 and Oracle Solaris 10 8 07 TABLE 3 10 Oracle Solaris OS Issues Fixed in Oracle Solaris 10 8 07 M4000 M8000 CR ID M3000 M5000 M9000 Description Workaround 6303418 O A M9000 server with a single domain For Oracle Solaris 10 11 06 this has and 11 or more fully populated system been fixed in patch 120011 01 boards might hang under heavy stress Workaround Do not exceed 170 CPU threads Limit the number of CPU threads to one per CPU core by using the Oracle Solaris psradm command to disable the excess CPU threads For example disable all odd numbered CPU threads 6416224 O O System performance can degrade using For Oracle Solaris 10 11 06 this has a single NIC card with more than 5 000 been fixed in patch 120011 08 connections Workaround Use multiple NIC cards to split network connections 6441349 O O The system may hang if there is an I O For Oracle Solaris 10 11 06 this has error in the system been fixed in patch 120011 07 No workaround is available 6485555 O O On board Gigabit Ethernet NVRAM For Oracle Solaris 10 11 06 this has corruption could occur due to a race condition The window of opportunity for this race condition is very small been fixed in patch 120011 08 No workaround is available Chapter 3 Information About Software 61 TABLE 3 10 Oracle Solaris OS Issues Fixed in Oracle Solaris 10 8 07 Continued M4000 M8000 CR ID M3000 M5000 M9000 Des
12. 2 0 3 5 9 3 6 22 Firefox Oracle Solaris 11 6 0 4 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 CHAPTER 2 XCP 1110 and XCP 1110 related Information This section describes the information about XCP 1110 and XCP 1110 related information What s New in XCP 1110 on page 5 Notes and Limitations on page 5 XCP 1110 Issues and Workarounds on page 11 Updating to XCP 1110 on page 12 What s New in XCP 1110 In XCP version 1110 the following new feature is introduced The restoredefaut 8 command is supported For detail see SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers XSCF Reference Manual or XSCF man pages You can specify either 1024 bit or 2048 bit as the size of the RSA host public key by SSH service For detail see SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers XSCF Reference Manual or XSCF man pages Notes and Limitations This section describes the notes and limitations at the time of this release Limitations for SPARC64 VII and SPARC64 VII Processors You must complete the upgrades to the XCP and to Oracle Solaris OS before installing the CPU memory board unit which is mounted with the SPARC 64 VII and SPARC64 VII processors on your server Notes on Active Directory a While Active Directory is enabled when you attempt to login to XSCF via the telnet you might fail to login due to timeout of the query to secondary alter
13. Archives menu of XSCF Web is not supported 10 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 m When you use the external power control interface of the external power controller the following notification signals are not supported a The OS panic or the server hardware error signal CPUN RTNU a The server hardware error signal power fail temperature error and fan error ALARM M8000 M9000 servers On the M8000 M9000 servers with XCP 1050 or later the dual XSCF Unit feature is working Therefore you can not downgrade M8000 M9000 servers with XCP 1050 or later to XCP 1040 or XCP 1041 which does not support dual XSCF Unit feature a You cannot use the following user account names as they are reserved for system use root bin daemon adm operator nobody sshd rpc rpcuser ldap apache ntp admin proxyuser and default m XSCF LAN is compliant with auto negotiation When you connect XSCF LAN and the network device which has been fixed to the full duplex mode according to the IEEE 802 3 rule XSCF LAN communicates in the half duplex mode Due to this network communication speed may slow down or communication error may occur Do not fail to set the network device which connects with XSCF LAN to the auto negotiation mode m M4000 M5000 M8000 M9000 servers While you are performing DR operation to a COD board do not execute the addcodactivation 8 addcodlicense 8 deletecodactivation 8
14. DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID SS com Ca Adobe PostScript Copyright 2012 Fujitsu Limited Tous droits r serv s Oracle et ou ses soci t s affili es ont fourni et v rifi des donn es techniques de certaines parties de ce composant Oracle et ou ses soci t s affili es et Fujitsu Limited d tiennent et contr lent chacune des droits de propri t intellectuelle relatifs aux produits et technologies d crits dans ce document De m me ces produits technologies et ce document sont prot g s par des lois sur le copyright des brevets d autres lois sur la propri t intellectuelle et des trait s internationaux Ce document le produit et les technologies aff rents sont exclusivement distribu s avec des licences qui en restreignent l utilisation la copie la distribution et la d compilation Aucune partie de ce produit de ces technologies ou de ce document ne peut tre reproduite sous quelque forme que ce soit par quelque moyen que ce soit sans l autorisation crite pr alable d Oracle et ou ses soci t s affili es et de Fujitsu Limited et de leurs ventuels bailleurs de licence Ce document bien qu il vous ait t fourni ne vous conf re aucun droit et aucune licence expresses ou tacites concernant le produit ou la technologie auxquels il se rapporte Par ailleurs il ne contient ni ne repr sente aucun engagement de quelque type que ce soit de la part d Orac
15. E541 a SPARC Enterprise M4000 M5000 Servers Documentation CD C120 E365 m SPARC Enterprise M8000 M9000 Servers Documentation CD C120 E364 Manual on the Enhanced Support Facility x x CD ROM disk Remote maintenance service a Enhanced Support Facility User s Guide for REMCS C112 B067 Information Required for Server Operation The latest information about the support for your server are provided on the websites m Message Global Site http www fujitsu com sparcenterprise msg Japanese Site http jp fujitsu com platform server sparcenterprise msg m Firmware program For the information on how to get the latest files of firmware contact your sales representative The following files or document are provided a Firmware program file XSCF Control Package XCP file Preface xiii a XSCF extension MIB OPL SP MIB definition file Note XSCF Control Package XCP XCP is a package which has the control programs of hardware that configures a computing system The XSCF firmware and the OpenBoot PROM firmware are included in the XCP file a Fault Management MIB SUN FM MIB definition file http src opensolaris org source xref onnv onnv gate usr src lib fm libfmd_snmp mibs Documentation Feedback If you have any comments or requests regarding this document or if you find any unclear statements in the document please state your points specifically on the form at the following website http www
16. Enterprise M3000 M4000 M5000 M8000 M9000 Servers Administra C120 E331 tion Guide SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers XSCF User s C120 E332 Guide SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers XSCF Refer Varies per ence Manual release SPARC Enterprise M4000 M5000 M8000 M9000 Servers Dynamic C120 E335 Reconfiguration DR User s Guide SPARC Enterprise M4000 M5000 M8000 M9000 Servers Capacity on Demand C120 E336 COD User s Guide SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers RCI User s C120 E360 Guide SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers Product Notest Varies per release SPARC Enterprise M3000 Server Product Notes Varies per release SPARC Enterprise M4000 M5000 Servers Product Notes Varies per release SPARC Enterprise M8000 M9000 Servers Product Notes Varies per release xii SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 Related SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers Documents Manual Code External I O Expansion Unit Product Notes C120 E456 SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers Glossary C120 E514 SPARC Enterprise PRIMEQUEST Common Installation Planning Manual C120 H007 This is a printed document t Beginning with the XCP 1100 release Documentation CD For the Documentation CD please contact your local sales representative m SPARC Enterprise M3000 Server Documentation CD C120
17. and or licensed from the suppliers to Oracle and or its affiliates and Fujitsu Limited including software and font technology Per the terms of the GPL or LGPL a copy of the source code governed by the GPL or LGPL as applicable is available upon request by the End User Please contact Oracle and or its affiliates or Fujitsu Limited This distribution may include materials developed by third parties Parts of the product may be derived from Berkeley BSD systems licensed from the University of California UNIX is a registered trademark in the U S and in other countries exclusively licensed through X Open Company Ltd Oracle and Java are registered trademarks of Oracle and or its affiliates Fujitsu and the Fujitsu logo are registered trademarks of Fujitsu Limited All SPARC trademarks are used under license and are registered trademarks of SPARC International Inc in the U S and other countries Products bearing SPARC trademarks are based upon architectures developed by Oracle and or its affiliates SPARC64 is a trademark of SPARC International Inc used under license by Fujitsu Microelectronics Inc and Fujitsu Limited Other names may be trademarks of their respective owners United States Government Rights Commercial use U S Government users are subject to the standard government user license agreements of Oracle and or its affiliates and Fujitsu Limited and the applicable provisions of the FAR and its supplements Disclaimer
18. certificate 38 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 TABLE 3 3 XCP Issues Fixed in Releases Earlier Than XCP 1110 Continued M4000 M8000 ID M3000 M5000 M9000 Description Workaround RTIF1 O O O The XSCF might go down and require a Use only user accounts with a user ID 090824 001 reboot or you might see console error UID value between 100 and 60000 messages and a core dump This is the range of auto assigned UIDs ereport chassis software core for the XSCF command adduser 8 when one of these conditions occurs e A local account has been created with a user ID explicitly assigned to a value larger than 65536 adduser u uid e An LDAP account has been used that has a UID value larger than 65536 RTIF1 O O O While Active Directory is enabled if No workaround is available 091021 001 you log in to XSCF using the user name that registered in the Active Directory server the showconsolepath 8 command displays not the log in user name but proxyuser RTIF1 O O O The loadcert console operand is For how to use the loadcert console 091105 001 missing in the usage of the setad 8 operand of the setad 8 command and command and the setldapss1 8 the set ldapss1 8 command see the command man page RTIF1 O O O Once domain detected a failure related This error log can be safely ignored 091109 001 to DIMM or PCI the error log about this detected failure is registered every time you rese
19. medium in advance 87 The data stored will include the information about the system To use USB memory you need to pay attention to the management of the USB memory in which the data stored from the data security viewpoint We do not provide guarantees to every USB memory from any manufacturers that currently on the market against its connectivity to XSCF and proper operation Depending on the USB memory in use defects such as the XSCF firmware error or reset may occur In case such defects occurred stop the use of USB memory immediately To connect the USB memory to the USB port for XSCF connect the USB memory directly to the USB port If connected via USB hub or USB extension cables it may cause errors Power Control and Operator Panel Mode Switch Note Before using the RCI function see Notes on RCI Function on page 13 When you use the remote power control utilizing the RCI function or the automatic power control system APCS you can disable this remote power control or the APCS by setting the mode switch to Service mode on the operator panel Disabling these features ensures that you do not unintentionally switch the system power on or off during maintenance Note that system power off with the APCS cannot be disabled with the mode switch Therefore be sure to turn off automatic power control via APCS before starting maintenance If you switch the mode while using the RCI or the automatic power control the
20. par Oracle et ou ses soci t s affili es SPARC64 est une marque de SPARC International Inc utilis e sous licence par Fujitsu Microelectronics Inc et Fujitsu Limited Tout autre nom mentionn peut correspondre a des marques appartenant a d autres propri taires United States Government Rights Commercial use U S Government users are subject to the standard government user license agreements of Oracle and or its affiliates and Fujitsu Limited and the applicable provisions of the FAR and its supplements Avis de non responsabilit les seules garanties octroy es par Oracle et Fujitsu Limited et ou toute soci t affili e de l une ou l autre entit en rapport avec ce document ou tout produit ou toute technologie d crits dans les pr sentes correspondent aux garanties express ment stipul es dans le contrat de licence r gissant le produit ou la technologie fournis SAUF MENTION CONTRAIRE EXPRESSEMENT STIPULEE DANS CE CONTRAT ORACLE OU FUJITSU LIMITED ET LES SOCI T S AFFILIEES A L UNE OU L AUTRE ENTITE REJETTENT TOUTE REPRESENTATION OU TOUTE GARANTIE QUELLE QU EN SOIT LA NATURE EXPRESSE OU IMPLICITE CONCERNANT CE PRODUIT CETTE TECHNOLOGIE OU CE DOCUMENT LESQUELS SONT FOURNIS EN L TAT EN OUTRE TOUTES LES CONDITIONS REPRESENTATIONS ET GARANTIES EXPRESSES OU TACITES Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALIT MARCHANDE A L APTITUDE A UNE UTILISATION PARTICULI RE OU A L ABSENCE DE CONTREFA ON SON
21. qelete the following setting from Unit adding by hotplug or the FMEMA etc system operating by DR set pcie_expected_ce_mask 0x2001 SUNW MSG ID SUN4 8000 75 TYPE Fault VER 1 SEVERITY Workaround Critical are Add the following to etc system Pra and then reboot the domain DESC A problem was detected in the set pcie expected ce mask PCI Express subsystem 0x2001 a Refer to http sun com msg SUN4 8000 75 for more information 6720261 O O O M4000 M5000 M8000 M9000 servers This has been fixed in patch 137137 09 If your domain is running one of the following versions of Oracle Solaris OS the system might panic trap during normal operation e Oracle Solaris 10 5 08 OS e An earlier version of Oracle Solaris 10 OS with patch ID 127127 11 M3000 server If your domain is running Oracle Solaris 10 5 08 OS the system might panic trap during normal operation Workaround Set the following parameter in the system specification file etc system set heaplp use _stlb 0 Then reboot the domain Chapter 3 Information About Software 55 Oracle Solaris OS Issues Fixed in Oracle Solaris 10 5 08 TABLE 3 9 lists issues that have been fixed in Oracle Solaris 10 5 08 OS You might encounter them in supported releases earlier than Oracle Solaris 10 5 08 TABLE 3 9 Oracle Solaris OS Issues Fixed in Oracle Solaris 10 5 08 M4000 M8000 CR ID M3000 M5000 M9000 Description Workaround 5076574 O A PCIe e
22. the operation disabling email report is completed even if C is used e showemailreport can be used to confirm that the email service has been disabled RTIF1 O O While executing the firmware update Do not execute the import of XCP by 070914 001 by using the flashupdate 8 using the getflashimage 8 command command or BUI when the import of XCP executed by using the getflashimage 8 command or BUI the firmware update aborts or BUI while executing the firmware update 24 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 TABLE 3 3 XCP Issues Fixed in Releases Earlier Than XCP 1110 Continued M4000 M8000 ID M3000 M5000 M9000 Description Workaround RTIF1 O O When the XSCF switching performed Execute the showhardconf 8 070914 002 the monitor message doesn t show the command to refer to the state of XSCF number of XSCF unit which turned unit active RTIF1 O O When the XSCF switching performed No workaround is available 070914 003 there may be SCF Board control This message can be safely ignored error DMA timeout stored in the error log RTIF1 O O On the XSCF Web when using Internet None available at this time 070914 005 Explorer 7 on the User Accounts screen User Local Accounts doesn t show the Status of each user RTIF1 O O When you set the XSCF user account Use up to 31 characters to set the XSCF 070914 006 name to the maximum 32 characters user account name
23. this event occurred change the environmental variable auto boot setting to false and use the reset all command to reset the domain Then specify the correct value after of the disk node and execute the boot command 40 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 TABLE 3 3 XCP Issues Fixed in Releases Earlier Than XCP 1110 Continued M4000 M8000 ID M3000 M5000 M9000 Description Workaround RTIF1 O When you use the setroute 8 To set the gateway address confirm 101029 001 command to set the gateway address that the specified address is correct and if you mistake the setting or the Before resetting XSCF by using the gateway has been stopped XSCF hangs repootxscf 8 command confirm that up the gateway is operating properly RTIF1 O When the RCI of XSCF 0 and XSCF 1 No workaround is available 101102 001 both got the communication error the RCI asynchronous monitoring of PRIMECLUSTER does not stop normally but gets the monitoring timeout which delays the switching of the clusters after the error detected RTIF1 O O O While XSCF is running a process may No workaround is available 101215 001 go down After this XSCF may reset This error log can be safely ignored RTIF1 O When you execute the No workaround is available 110216 001 showenvironment power command The correct value is 505 W for AC on the M3000 server with SPARC64 power supply model and is 510 W for VII process
24. with SPARC64 VII processors 6449315 O The Oracle Solaris OS cfgadm 1M command does not unconfigure a DVD drive from a domain on a M8000 M9000 server This has been fixed in patch 144563 02 Workaround No workaround is available Disable the Volume Management Daemon vold before unconfiguring a DVD drive with the cfgadm 1M command To disable vold stop the daemon by issuing the command etc init d volmgt stop After the device has been removed or inserted restart the daemon by issuing the command etc init d volmgt start 42 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 TABLE 3 4 Oracle Solaris OS Issues and Workarounds for All Supported Releases Continued M4000 M8000 CR ID M3000 M4000 M9000 Description Workaround 6459540 O O The DAT72 internal tape drive on a Add the following definition to server may time out during tape kernel drv st conf operations The device might also be identified by the system as a QIC drive tapi contig iist SEAGATE DAT DAT72 000 SEAGATE DA DAT72 000 SEAGATE DA DAT72 000 SEAGATE DAT DAT72 000 1 0x34 0 0x9639 4 0x00 0x8c 0x 8c Ox8c 3 There are four spaces between SEAGATE DAT and DAT72 000 6466617 O O Performing a hot plug operation with Pause a few seconds between the issue the PCI Express slot too quickly of each cfgadm c command interrupts a PCI leaf reset and occurs the following err
25. 08 Oracle Solaris 10 5 08 No patches required No patches required No patches required No patches required No patches required No patches required 119254 59 138866 01 137137 09 138504 04 If 8GB DIMM is installed on a server update XCP to XCP 1081 or later t XCP 1080 is the first XCP release for the M3000 server t For more information on the PTF contact a sales representative or a qualified service engineer Apply 118833 36 before 125100 04 Chapter 1 Software Requirements 3 Note You cannot boot a domain mounted with the SPARC64 VII processors using the Oracle Solaris 10 8 07 installation DVD Use the Oracle Solaris 10 5 08 or later installation DVD to boot a domain mounted with the SPARC64 VII processors For additional Oracle Solaris OS information see Oracle Solaris OS Issues and Workarounds on page 42 Obtaining XCP and Oracle Solaris Patches For the information on how to get the latest XCP firmware or the latest patch for Oracle Solaris OS contact your sales representative Web Browser Many web browsers support the XSCF Web The browsers in TABLE 1 2 have demonstrated compatibility with the XSCF Web through testing For other information about XSCF Web see Notes on XSCF Web on page 9 TABLE 1 2 Tested Web Browser Versions Web Browser Application Version Microsoft Internet Explorer 6 0 7 0 8 0 9 0 Firefox Windows 3 6 25 8 0 9 0 Firefox Oracle Solaris 10
26. 081030 002 RTIF1 081104 001 RTIF1 090108 001 RTIF1 090108 002 RTIF1 090108 004 O O O When the timezone other than three characters has been set the error logs cannot be displayed on XSCF Web Error Log page In addition XSCF Web Panic Log and IPL Message Log pages display the date on the table with The monitor message log might not be registered when a PCI slot error detected The domain console may display this message ipsec_check_inbound_policy Policy Failure for the incoming packet not secure In the dual power feed system when the power failure and the power recovery occurred repeatedly on one line all domains will be forcibly powered off And in the power recovery from the forced power off a PSU illegal configuration might be registered in the error log and the power recovery might not be started When you replaced the XSCF unit by using the replacefru 8 command there may be the DB synchronization timeout error log and the replacement may fail Use the showlogs 8 command on the XSCF shell No workaround is available Use the showlogs error command or the mdump command to check the fault information of PCI slot This message can be safely ignored You need to remove and insert the power cable Turn off all mainline switches and then turn on again Or just after the XSCF reset using the rebootxscf 8 command execute the replacefru 8 command and extra
27. 116 001 misleading message regarding the the maintenance menu of the addfru 8 board being unavailable for DR after or replacefru 8 command In case of the addfru 8 or replacefru 8 missing the diagnostic test in the command have been used for active maintenance menu of the addfru 8 or replacement This happens when the the replacefru 8 command execute active replacement is done without the the testsb 8 command or delete the diagnostic test in the maintenance CPU memory board unit using the menu deletefru 8 command and then retry the addfru 8 command RTIF1 O O Using the XSCF Web when you Use showcodusage 8 command to 071116 003 selected COD codusage details display the cod usage cannot be displayed correctly 28 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 TABLE 3 3 XCP Issues Fixed in Releases Earlier Than XCP 1110 Continued M4000 M8000 ID M3000 M5000 M9000 Description Workaround RTIF1 O O When Internet Explorer 7 browser is Use deletecodlicense 8 command 071116 004 used the License key deletion cannot be to delete a license key Or use other executed on the BUI COD page browsers e Microsoft Internet Explorer 6 0 e Firefox 2 0 or later e Netscape Navigator 7 1 or later RTIF1 O While system power on when the XSCF No workaround is available This 071116 005 switching performed by switchscf 8 message can be safely ignored command PANIC might be generated in XSCF befo
28. 29 characters or more use XSCF 090427 004 number of characters which can be Shell specified differs between XSCF Web and XSCF Shell On XSCF Web you can enter up to 128 characters RTIF1 O O O After you set https using the self To set the self certificate authority do 090430 001 certificate authority by XSCF and not specify a blank character created a web server certificate https is not enabled RTIF1 O O O In a domain mounted with the 10 The entire output can be safely ignored 090508 001 Gigabit Ethernet card SE0X7HE1F To avoid these outputs execute the when you set the OpenBoot PROM following command at the ok prompt environmental variable diag switch and set the OpenBoot PROM to true the following warning environmental variable diag switch message appears on the console and at to false the same time Msg Device error setenv diag switch false FCode informed error is recorded in the error log WARNING pci 7 700000 FCODE map in doesn t match decoded register type And when you execute the showstatus 8 command Degraded might be indicated to the FRU which has installed the relevant card RTIF1 O O O When you use the sethttps 8 Specify up to 100 characters in the 090729 001 command to create a self signed web parameter and execute the sethttps 8 server certificate if the number of command again characters specified in a parameter exceeds 100 it might result in an internal error and you might fail to create the
29. 3000 Server Overview Guide SPARC Enterprise M4000 M5000 Servers Overview Guide SPARC Enterprise M8000 M9000 Servers Overview Guide SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers Important Legal and Safety Information SPARC Enterprise M3000 Server Safety and Compliance Guide SPARC Enterprise M4000 M5000 Servers Safety and Compliance Guide SPARC Enterprise M8000 M9000 Servers Safety and Compliance Guide C120 H030 C120 H015 C120 H014 C120 H016 C120 E536 C120 E345 C120 E323 C120 E537 C120 E346 C120 E324 C120 E633 C120 E538 C120 E348 C120 E326 Preface xi Related SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers Documents Manual Code External I O Expansion Unit Safety and Compliance Guide C120 E457 SPARC Enterprise M4000 Server Unpacking Guide C120 E349 SPARC Enterprise M5000 Server Unpacking Guide C120 E350 SPARC Enterprise M8000 M9000 Servers Unpacking Guide C120 E327 SPARC Enterprise M3000 Server Installation Guide C120 E539 SPARC Enterprise M4000 M5000 Servers Installation Guide C120 E351 SPARC Enterprise M8000 M9000 Servers Installation Guide C120 E328 SPARC Enterprise M3000 Server Service Manual C120 E540 SPARC Enterprise M4000 M5000 Servers Service Manual C120 E352 SPARC Enterprise M8000 M9000 Servers Service Manual C120 E330 External I O Expansion Unit Installation and Service Manual C120 E329 SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers RCI Build Pro C120 E361 cedure SPARC
30. 6 is similar RTIF1 O O Attempting to move a COD board using Use the deleteboard 8 and 070418 021 the moveboard 8 command might fail addboard 8 commands instead of the moveboard 8 command RTIF1 O O The XSCF firmware monitors itself and Allow the XSCF Unit to finish resetting 070418 022 if it detects any abnormalities it will It will return to normal operation force a reset within approximately 5 minutes RTIF1 O O Using the rebootxscf 8 command Ignore this event 070418 023 may result in a process down error and possibly an FMA event with MSG ID SCF 8005 NE RTIF1 O O showaudit all shows a long listof Update the database with the following 070418 025 defaults in the policy section after the setaudit a opl enable database is cl ared setaudit a opl default RTIF1 O O When you have updated the No workaround is available 070528 001 etc ttydefs file of Oracle Solaris OS to disable the console flow control you cannot disable the console flow control on the telnet via a server 20 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 TABLE 3 3 XCP Issues Fixed in Releases Earlier Than XCP 1110 Continued M4000 M8000 ID M3000 M5000 M9000 Description Workaround RTIF1 O O O While XSCF is running watchdog M4000 M5000 M8000 M9000 servers 070528 002 timeout may occur and XSCF may Check that XSCF is started If not reboot started stop all the domains and then execute the system power off on
31. 9000 Description Workaround 6499304 O O CPU isn t offlined and unexpected For Oracle Solaris 10 11 06 this has message is displayed on console when been fixed in patch 125369 05 many correctable error CE occurs Example Workaround SUNW MSG ID FMD 8000 11 Check CPU status on XSCF TYPE Defect VER 1 SEVERITY Minor EVENT TIME Fri Feb 2 18 31 07 JST 2007 PLATFORM SPARC Enterprise CSN BE80601035 HOSTNAME FF2 35 0 6502204 O O Unexpected error messages may be For Oracle Solaris 10 11 06 this has displayed on console on booting after been fixed in patch 125369 05 CPU UE panic Example Workaround SUNW MSG ID FMD 8000 11 If you see unexpected messages use the YPE Defect VER 1 XSCF command SEVERITY Minor EVENT TIME showdomainstatus 8 to check system Tue Jan 9 20 45 08 JST 2007 status on XSCE PLATFORM SUNW SPARC Enterprise CSN 2030636002 HOSTNAME P2 DC1 16 d0 6502750 O O Notification message for inserted or For Oracle Solaris 10 11 06 this has removed card by PCI hot plug may not been fixed in patch 120011 08 output No workaround is available 6508432 O O Many correctable errors CE may occur For Oracle Solaris 10 11 06 this has and despite these are the correctable been fixed in patch 120011 08 errors domain may panic Workaround Set the following to etc system and then reboot the domain set pcie pcie aer ce mask 0x2001 6508434 O O The domain may panic when an For Oracle Solaris 10 11 06 this has
32. ARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 CHAPTER 5 Information About Hardware of M4000 M5000 Servers This section describes the special instructions and the issues about the M4000 M5000 servers hardware a Notes and Limitations on page 81 a Hardware Issues and Workarounds on page 84 a Hardware Documentation Updates on page 84 Notes and Limitations Notes on Server Installation The plug NEMA L6 20 of the power cables supplied with the M4000 M5000 servers has the following dimensions Confirm in advance that the plug does not become an obstruction when plugged into the input power source at the installation site m Outside diameter of the connector part of the plug 50 mm Maximum outside diameter of the plug cover 57 mm m Plug cover length from the connector end 69 9 mm Notes on DVD Drive and Discs See the Notes on DVD Drives and Discs in SPARC Enterprise on the website below before using the CD DVD discs in the standard DVD drive mounted in this server 81 http www fujitsu com sparcenterprise manual Notes on the Use of USB Memory To execute the dumpconfig 8 restoreconfig 8 or snapshot 8 command if you specify USB memory as the destination to store data prepare the USB memory as a medium in advance The data stored will include the information about the system To use USB memory you need to pay attention to the management of the USB mem
33. F and XSCF reset the subsequent SNMP traps will not be notified Chapter 3 Information About Software 15 TABLE 3 1 Known Issues and Workarounds in XCP 1110 Continued ID M4000 M8000 M3000 M5000 M9000 Description Workaround RTIF1 081016 002 RTIF1 081225 001 RTIF1 090108 003 RTIF1 090427 005 RTIF1 090731 001 RTIF1 100331 002 RTIF1 110222 001 O O O O O O O O O When FRUs are cold replaced with the system off after poweron the monitor process might not generate entries in the monitor message log identifying the replacement operation that has occurred In the settimezone c adddst command when you set eight or more letters to the abbreviation of time zone and the name of Daylight Saving Time execution of the showlogs command induces a segmentation fault and results in an error Date and time of the Last Update which displayed on the XSCF Web may not be updated When you use the setpasswordpolicy 8 command and set 9999999999 10 digits in Different Characters the showpasswordpolicy 8 command displays 1 While a DIMM correctable error CE has been occurred when XSCF failover is started a message XSCFU hang up is detected might appear in the error log When you start up a domain from a disk that is connected to the 8 Gbps fibre channel card SEOX7F21F SEOX7F22F and if it is unable to start the domain due to causes such as disk
34. F1 070914 013 RTIF1 070914 014 RTIF1 070914 015 O O On the XSCF Web on the SNMPv3 Security Settings screen when you select Change Password of the SNMP User Based Security Model USM the Change Password screen appears as a pop up On this screen despite the Confirm Password is a field which must be entered it is not displayed with the note Indicates require field On the XSCF Web on the SNMP Properties screen when you don t select Trap Host and execute the Remove button the invalid message The trap host will be removed appears as a pop up And when you select OK on the pop up screen the invalid message Remove trap host failed setsnmp invalid trap type appears On the XSCF Web on the Audit Properties screen when you execute the Add Policy button the Set User Policy appears as a pop up On this screen when you specified a user name which is not registered in XSCF and an input error resulted the value entered won t be cleared though you execute the Reset button to clear the specified user name On the XSCF Web when you use a user account without an appropriate privilege to select Snapshot set the parameters of Start time or End time and execute the Download button it doesn t result in a privilege error but the parameter error will be displayed On the XSCF Web when you select User Manager to add the user account the user name to be specified is li
35. Function The REMCS agent function is enabled as the default settings To enable or disable the REMCS agent function contact a field engineer The Timezone Setting for REMCS Agent Function The REMCS agent uses the current server timezone So when you change the server timezone by XSCF the Periodical Connection Schedule setting is required again for updating the information of the REMCS center XCP Issues and Workarounds This section contains information about XCP issues TABLE 3 1 TABLE 3 2 and TABLE 3 3 list issues you might encounter depending upon which XCP release you are using 14 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 Known Issues and Workarounds in XCP 1110 TABLE 3 1 lists known XCP issues and possible workarounds in XCP 1110 TABLE 3 1 Known Issues and Workarounds in XCP 1110 M4000 M8000 ID M3000 M5000 M9000 Description Workaround RTIF1 O When you execute XCP Sync on the No workaround is available However 070914 025 Firmware Update page after 15 the XCP Sync process has been minutes the error message Another continuously executed Check the XSCF flashupdate is now processing update completion message on the or The page cannot be monitoring message to confirm the displayed may appear completion of Sync process RTIF1 O DR operations might fail with a Do not fail to execute the diagnosis in 071116 001 misleading message regarding the the main
36. M4000 M5000 M8000 M9000 Servers RCI Build Procedure and the SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers RCI User s Guide To use the APCS see the Enhanced Support Facility User s Guide for Machine Administration Automatic Power Control Function Supplement Edition Limitation for 1027A Z X1027A Z For 1027A Z X1027A Z PCIe Dual 10 Gigabit Ethernet Fiber XFP cards this maximum limit apply m No more than one card in an M3000 server Limitation for 4447A Z X4447A Z For PCIe Quad port Gigabit Ethernet UTP Low Profile Adapter 4447A Z X4447A Z this maximum limit apply a No more than four cards in an M3000 server Patches for Emulex PCI Express PCIe Adapters The following Emulex PCle adapters require drivers supplied in patch 120222 26 a Sun StorageTek Enterprise Class 4Gb Dual Port Fibre Channel PCIe HBA XSEFC402AF m Sun StorageTek Enterprise Class 4Gb Single Port Fibre Channel PCIe HBA XSEFC401 AF 74 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 Hardware RAID Function RAID technology enables the construction of a logical volume made up of several physical disks to provide data redundancy improved performance or both The on board SAS controller of the M3000 server which consists of the SPARC64 VII processors supports RAID 1 mirroring volumes using the Oracle Solaris OS raidctl utility Supported Conditions This section lists supported conditions for
37. M9000 Description Workaround 6724307 O Scheduler decisions systems are This has been fixed in patch 141414 01 occasionally unbalanced Sometimes two threads will be on one Workaround Soe causing port iO tum a about E Use processor sets to prevent uneven speed while another core is idle For threads to core assignment many OpenMP and similar parallel applications the application performance is limited by the speed of the slowest thread Uneven scheduling is not common perhaps 1 in 50 or 1 in 100 decisions But if there are 128 threads running then the application might have at least one uneven schedule event 6800734 O O The deleteboard 8 command hangin This has been fixed in patch 141444 09 a domain No workaround is available 6816913 O O The XSCF showdevices 8 command Use the prtdiag 1M command on the displays the incorrect processor cache domain to report processor information size MB for fractional processor cache sizes such as displaying 5 when the correct display would be 5 5 6821108 O O DR and showdevices 8 command do This has been fixed in patch 140589 02 not work after XSCF reset Workaround Reset the XSCF service processor twice Half the SAs Security Associations are deleted the first time half are deleted the second time so the second addition succeeds and IPsec communication is reestablished 6827340 O O O DR and Memory patrol might fail due This has been fixed in patch 142344 01
38. Number Update SPARC Enterprise M8000 M9000 Servers Site Planning Guide SPARC Enterprise M8000 M9000 Servers Installation Guide 1 35 For the order number of Vibration proof bracket and Vibration proof feet see Cabinet Stabilization Measures on page 92 TABLE 2 3 Power Supply Connection Specifications The following note will be added Note For the servers that have the plug with lock function confirm that a 30A overcurrent protection device is available outside the server If one is not available prepare an external 30A overcurrent protection that can be achieved by means of no fuse breakers NFBs or fuses The plug with lock function refers to plugs other than grounding type ones with two parallel blades such as the NEMA L6 30 L6 20 L6 15 and L5 15 90 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 TABLE 6 2 Hardware Documentation Updates Continued Title Page Number Update 3 39 The step 1 Confirm that the system is powered on in 3 7 5 Checking the Dual Power Feed will be changed to Confirm that the system is powered on by checking the output of the showdomainstatus a command from the XSCF Shell SPARC Enterprise 4 10 4 5 Verifying the Operation Using the Oracle VTS Software M8000 M9000 Servers Step 3 Installation Guide The following description will be deleted For details on items to be diagnosed see the test reference manual for Oracle VT
39. S Chapter 6 Information About Hardware of M8000 M9000 Servers 91 Miscellaneous Information Cabinet Stabilization Measures This section shows useful methods of securing an M8000 M9000 server to prevent it from shifting due to vibration Method of Securing the Cabinet to the Floor Surface Vibration proof Bracket m order number CA06620 H901 By specifying the above you can issue an order to get the following four kinds of parts You should order the bolt separately Fixing bracket C230 4130 X514 x4 Bushing C230 4080 X003 x4 Metal washer F6 WB12 121 x4 Metal washer F6 WM12 121 x4 m Bolt F6 B12 121 Bolt diameter M12 Bolt length mm The bolt length must be specified here Note Consult with the company that constructed the building because the length depends on the structure of the building Vibration proof Feet m order number CA06620 H902 By specifying the above you can issue an order to get the following parts You should order the bolt separately a F6 DA6G x4 Change this board leg height adjustment leg to the F6 DA6G and tighten the bolt from under the floor 92 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 Bolt diameter M20 Bolt length 15 mm floor thickness Note Consult with the company that constructed the building because the length depends on the structure of the building Chapter 6 Information Abo
40. T EXCLUES DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE Sauf mention contraire express ment stipul e dans ce contrat dans la mesure autoris e par la loi applicable en aucun cas Oracle ou Fujitsu Limited et ou l une ou l autre de leurs soci t s affili es ne sauraient tre tenues responsables envers une quelconque partie tierce sous quelque th orie juridique que ce soit de tout manque a gagner ou de perte de profit de probl mes d utilisation ou de perte de donn es ou d interruptions d activit s ou de tout dommage indirect sp cial secondaire ou cons cutif m me si ces entit s ont t pr alablement inform es d une telle ventualit LA DOCUMENTATION EST FOURNIE EN L TAT ET TOUTE AUTRE CONDITION DECLARATION ET GARANTIE EXPRESSE OU TACITE EST FORMELLEMENT EXCLUE DANS LA MESURE AUTORISEE PAR LA LOIEN VIGUEUR Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALIT MARCHANDE A L APTITUDE A UNE UTILISATION PARTICULI RE OU A L ABSENCE DE CONTREFA ON Contents Preface ix Software Requirements 1 XCP Oracle Solaris OS and Required Patches 1 Obtaining XCP and Oracle Solaris Patches 4 Web Browser 4 XCP 1110 and XCP 1110 related Information 5 What s New in XCP 1110 5 Notes and Limitations 5 Limitations for SPARC64 VII and SPARC64 VII Processors 6 Notes on Active Directory 6 Notes on LDAP SSL 6 Notes on Power Consumption Monitoring Function M3000 Server 6 Notes on Airflow Indicato
41. TABLE 3 8 Oracle Solaris OS Issues Fixed in Oracle Solaris 10 10 08 CR ID M4000 M8000 M3000 M5000 M9000 Description Workaround 6511374 O O Unexpected error messages may be This has been fixed in patch 137137 09 displayed on console after changing the system configuration This message can be safely ignored Example WARNING Translation error source LSB0 B0 0 PA 3c000000000 target LSB0 B0 20000000 52 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 TABLE 3 8 Oracle Solaris OS Issues Fixed in Oracle Solaris 10 10 08 Continued M4000 M8000 CR ID M3000 M5000 M9000 Description Workaround 6533686 O O When XSCF is low on system resources This has been fixed in patch 138397 01 DR operations involving relocating permanent memory such as Workaround deleteboard 8 or moveboard 8 R he DR l might fail with one or more of these etry tie operabon ata tater time errors SCF busy DR parallel copy timeout This applies only to Quad XSB configured system boards hosting multiple domains 6535018 O In Oracle Solaris domains that include This has been fixed in patch 137111 01 SPARC64 VII processors workloads a sa eal ene oe ve Workaround te ey ee ee ee For Oracle Solaris domains that include expected when you increase the thread oe SPARC64 VII processors limit domains count to a value greater than 256 to a maximum of 256 threads 6608404 O Hot plug of the PCI
42. The only warranties granted by Oracle and Fujitsu Limited and or any affiliate of either of them in connection with this document or any product or technology described herein are those expressly set forth in the license agreement pursuant to which the product or technology is provided EXCEPT AS EXPRESSLY SET FORTH INSUCH AGREEMENT ORACLE OR FUJITSU LIMITED AND OR THEIR AFFILIATES MAKE NO REPRESENTATIONS OR WARRANTIES OF ANY KIND EXPRESS OR IMPLIED REGARDING SUCH PRODUCT OR TECHNOLOGY OR THIS DOCUMENT WHICH ARE ALL PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID Unless otherwise expressly set forth in such agreement to the extent allowed by applicable law in no event shall Oracle or Fujitsu Limited and or any of their affiliates have any liability to any third party under any legal theory for any loss of revenues or profits loss of use or data or business interruptions or for any indirect special incidental or consequential damages even if advised of the possibility of such damages DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE
43. Under Oracle Solaris 10 11 06 do not Use an alternate type of adapter or use the following adapters for network onboard network device to install the access when you are using the boot Oracle Solaris OS via the network net install command to install the Oracle Solaris OS e PCIe Quad port Gigabit Ethernet UTP Low Profile Adapter 4447A Z X4447A Z e PCIe Dual 10 Gigabit Ethernet Fiber XFP Low Profile Adapter 1027A Z X1027A Z 6542632 O O Memory leak in PCIe module if driver For Oracle Solaris 10 11 06 this has attach fails been fixed in patch 120011 09 No workaround is available Chapter 3 Information About Software 65 Software Documentation Updates This section contains late breaking software information that became known after the documentation set was published and corrections in the M3000 M4000 M5000 M8000 M9000 servers software documentation The corrections for SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers XSCF Reference Manual if not otherwise specified also apply to the man pages which XSCF provides And they supersede the information on the man pages TABLE 3 11 lists known documentation updates TABLE 3 11 Software Documentation Updates Title Page Number Update SPARC Enterprise 44 The description The HTTPS service starts immediately after M3000 M4000 M5000 being enabled in step 3 of section To Enable or Disable the M8000 M9000 Servers Administration Guide XSCF man pages p
44. XCP Version 1110 January 2012 2 Execute the following command XSCF gt showdevices d domain_id The following example shows a display of the showdevices d command where 0 is the domain_id XSCF gt showdevices d 0 Memory board perm base domain target deleted remaining DID XSB mem MB mem MB address mem MB XSB mem MB mem MB 00 00 0 8192 O 0x0000000000000000 24576 00 00 2 8192 1674 0x000003c000000000 24576 00 00 3 8192 O 0x0000034000000000 24576 The entry for column 4 perm mem MB indicates the presence of permanent memory if the value is non zero The example shows permanent memory on 00 2 with 1674 MB If the board includes permanent memory when you execute the deleteboard 8 command or the moveboard 8 command the following notice appears System may be temporarily suspended proceed y n Chapter 3 Information About Software 69 70 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 CHAPTER 4 Information About Hardware of M3000 Server This section describes the special instructions and the issues about the M3000 server hardware a Notes and Limitations on page 71 a Hardware RAID Function on page 75 a Hardware Documentation Updates on page 75 Notes and Limitations Notes on Hardware RAID Notes on Using the Hardware RAID m Make backup copies of important data and programs periodically In some failu
45. and you should change it to refer to another clock source When you change the clock source of an NTP server make sure in advance that it has no impact on other NTP clients Change the address of the local clock of the NTP server Of the NTP server which XSCF refers to change the address of the local clock to 127 127 1 1 127 127 1 2 or 127 127 1 3 Change etc inet ntp conf of Oracle Solaris OS To enable the change restart of the NTP daemon is required When you change the address of the local clock of an NTP server make sure in advance that it has no impact on other NTP clients Change the stratum value of the NTP server Of the NTP server which XSCF refers to change the stratum value to 1 An NTP server which has the stratum value of 1 becomes the most significant clock source and has no refid Therefore there is no chance that it will have the same address as the XSCF s own local clock When you change the stratum value of an NTP server make sure in advance that it has no impact on other NTP clients Change the address of the XSCF s own local clock By using the setntp m localaddr value command change the address of the XSCF s own local clock In value specify the least significant byte of the clock address of the local clock 127 127 1 x for value A numeric from 0 to 3 can be 8 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 specified By specifying either from 1 to 3 the ad
46. ases Earlier Than XCP 1110 Continued ID M3000 M5000 M9000 Description Workaround RTIF1 The initial value that set with the In the OpenBoot PROM prompt ok 080725 003 setdomparam set defaults option execute the set defaults command differs from the initial value of to restore the OpenBoot PROM OpenBoot PROM environmental variables to the initial parameters current value expected value value diag level none 0x00 min 0x20 auto boot false 0x00 true Oxff RTIF1 O After set the Daylight Saving Time by No workaround is available 080725 004 using the XSCF shell XSCF Web does Use the showlogs 8 command of the not show the correct time in the Logs XSCF shell menu RTIF1 On the cluster system using the Refer to the manual of the 080808 001 PRIMECLUSTER software when there PRIMECLUSTER software to check the are 10 or more RCI units the RCI busy cluster status If no problem found on status may be temporarily unreleased the status this message can be safely and output the following syslog ignored If any problem follow the message instructions on the manual to solve the SA_pprcir so to test host problem host_name failed RTIF1 O The error log XSCF FMEM write Power off AC OFF the system and 081006 001 error recorded and the firmware power on AC ON again Then re update might fail execute the firmware update RTIF1 O In the setemailreport 8 command Do not specify over 255 characters in 081006 002 when you specifie
47. atches required No patches required No patches required All patches contained in the PTF R10021 or later All patches contained in the PTF R10021 or later All patches contained in The PTF R10021 or later All patches contained in The PTF R10021 or later M4000 M5000 SPARC64 VII 2 53 GHz M8000 M9000 SPARC64 VII 2 88 GHz 1090 or later Oracle Solaris 11 11 11 Oracle Solaris 10 8 11 Oracle Solaris 10 9 10 Oracle Solaris 10 10 09 Oracle Solaris 10 5 09 Oracle Solaris 10 10 08 Oracle Solaris 10 5 08 Oracle Solaris 10 8 07 No patches required No patches required No patches required No patches required All patches contained in the PTF R10021 or later All patches contained in the PTF R10021 or later All patches contained in the PTF R10021 or later All patches contained in the PTF R10021 or later M4000 M5000 SPARC64 VII 2 4 GHz M8000 M9000 SPARC64 VII 2 52 GHz 1070 or later Oracle Solaris 11 11 11 Oracle Solaris 10 8 11 Oracle Solaris 10 9 10 Oracle Solaris 10 10 09 Oracle Solaris 10 5 09 Oracle Solaris 10 10 08 Oracle Solaris 10 5 08 Oracle Solaris 10 8 07 No patches required No patches required No patches required No patches required No patches required No patches required 137137 09 119254 51 or later 125891 01 or later 127755 01 or later 127127 11 2 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 TABLE 1 1 Supported XCP Oracle Solaris OS and Requir
48. ays current LDAP certificates will show proper data only when used with the same user account that had originally provided certificate information using setldap c Any other user account will generate Permission denied error Similarly the XSCF Web s LDAP Configuration pop up screen will display no data when a different user account is used On the User Account setting page on the User Manager screen after the password change resulted in Change Password Error when you click on the REFRESH button there appears the error message No user The request is aborted During the OpenBoot PROM process when you power off the domain the error log of Domain hang up detected level3 may be registered Since 0 is an invalid value in the LDAP Search Timeout do not fail to set a value other than 0 None available at this time The maximum 2147483647 seconds will be set to the LDAP Search Timeout The configuration is not deleted To show the configuration information again select LDAP from the Menu Use the same user account for all LDAP display or configuration operations for both CLI and XSCF Web To change the password select User Manager on the Menu again This error log can be safely ignored Chapter 3 Information About Software 27 TABLE 3 3 XCP Issues Fixed in Releases Earlier Than XCP 1110 Continued M4000 M8000 ID M3000 M5000 M9000 Description Workaround RTIF1 O O Whe
49. cO FUJITSU SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers Product Notes for XCP Version 1110 Manual Code C120 E669 01EN January 2012 Revision A Copyright 2012 Fujitsu Limited All rights reserved Oracle and or its affiliates provided technical input and review on portions of this material Oracle and or its affiliates and Fujitsu Limited each own or control intellectual property rights relating to products and technology described in this document and such products technology and this document are protected by copyright laws patents and other intellectual property laws and international treaties This document and the product and technology to which it pertains are distributed under licenses restricting their use copying distribution and decompilation No part of such product or technology or of this document may be reproduced in any form by any means without prior written authorization of Oracle and or its affiliates and Fujitsu Limited and their applicable licensors if any The furnishings of this document to you does not give you any rights or licenses express or implied with respect to the product or eee ae to which it pertains and this document does not contain or represent any commitment of any kind on the part of Oracle or Fujitsu Limited or any affiliate of either of them This document and the product and technology described in this document may incorporate third party intellectual property copyrighted by
50. can be safely ignored 080512 002 message as follows may appear on the No workaround is available XSCF console Output sample XX XXX XXX XXX mode 4 code 1 auth 0 clock filter n 8 off 0 000310 del 0 001300 dsp 0 001158 jit 0 000172 age 0 clock _update at 637535 assoc 2 local_clock assocID 54190 offset 0 000309657 freq 9 765 state 4 RTIF1 O O To a domain which is in Quad XSB Do not perform active addition of PCI 080512 003 configuration when you perform active cards When you failed in active addition of PCI cards and then restart addition of PCI cards stop the domain the domain active addition of PCI to add on the cards cards may become unavailable afterwards RTIF1 O BUI Domain Operation page mistakes Do not perform active addition of PCI 080520 001 the operation demand for Domain 8 or cards When you failed in active 9 and it issues it to DID 00 wrongly addition of PCI cards stop the domain to add on the cards RTIF1 O O When the system is stressed with many Reboot the service processor using the 080526 001 faults the fmd process on the service XSCF command rebootxscf 8 processor might hang Once this happens fma commands on the service processor can fail or hang RTIF1 O O The SNMP trap not notified in the event No workaround is available 080620 001 that the power cable of the server got unplugged accidentally Chapter 3 Information About Software 33 TABLE 3 3 XCP Issues Fixed in Rele
51. ces 8 command to refer to the domain hardware configuration Chapter 3 Information About Software 21 TABLE 3 3 XCP Issues Fixed in Releases Earlier Than XCP 1110 Continued M4000 M8000 ID M3000 M5000 M9000 Description Workaround RTIF1 070824 001 O O O RTIF1 070824 002 RTIF1 070824 003 RTIF1 070824 004 RTIF1 070824 005 M8000 M9000 servers When remote power control mode of interlocking mechanism for power supply to domain is enabled after XSCF Unit is replaced the interlocking for power supply by RCI cannot work M3000 M4000 M5000 servers When remote power control mode of interlocking mechanism for power supply to domain is enabled after the motherboard unit is replaced the interlocking for power supply by RCI cannot work On the XSCF Web when you select Domain Mode Configuration to perform various settings the pop up screen may not appear but Undefined may be displayed on the screen On the XSCF Web while the XCP import is in process from the Firmware Update screen when you execute the REFRESH button the pop up of Uploading Now disappears and the XCP import terminates abnormally On the XSCF Web on the Domain Status screen when you select an XSB displayed on the Domain Component List and in case the selected XSB is not yet mounted or is Uni XSB the pop up screen displays no data On the XSCF Web when you changed the Refresh Interval value of
52. cription Workaround 6496337 O O The cpumem diagnosis module may For Oracle Solaris 10 11 06 this has fail to load after uncorrectable error UE been fixed in patch 125369 05 panic Systems will function correctly but Workaround events normally e d If problem occurred implement the diagnosed by FMA using t is mo ule followin g will require manual diagnosis E i workaround xample P 1 Remove the following file SUNW MSG ID FMD 8000 2K TYPE Defect VER 1 Hrm SEVERITY Minor var fm fmd ckpt cpumem diagnosis cpumem diagnosis EVENT TIME Thu Feb 15 2 Restart fmd 15 46 57 JST 2007 ERS Soe nse PLATFORM SUNW SPARC svcadm restart fmd Enterprise CSN BE80601007 HOSTNAME col2 ff em7 d0 To avoid this problem in advance add rm f var fm fmd ckpt cpumem diagnosis cpumem diagnosis in lib svc method svc dumpadnm file as below We haven t run savecore on a dump device yet savedev none rm f var fm fmd ckpt cpumem diagnosis cpumem diagnosis 6498283 O O Using the DR deleteboard 8 For Oracle Solaris 10 11 06 this has command while psradm operations are been fixed in patch 120011 07 running on a domain might cause a Systemi panic No workaround is available 62 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 TABLE 3 10 Oracle Solaris OS Issues Fixed in Oracle Solaris 10 8 07 Continued M4000 M8000 CR ID M3000 M5000 M
53. ct and insert the XSCF unit which failed in replacement If time passed after the XSCF reset the replacefru 8 command may fail again In such a case re execute the reboot xsc 8 command and the subsequent processes 36 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 TABLE 3 3 XCP Issues Fixed in Releases Earlier Than XCP 1110 Continued M4000 M8000 ID M3000 M5000 M9000 Description Workaround RTIF1 O O O When you execute the settelnet c After you stopped the Telnet service 090115 001 disable command the Telnet service execute the rebootxscf 8 command will be stopped immediately However to reset XSCF unless you reset XSCF by using the rebootxscf 8 command you might fail in the subsequent restart of the Telnet service RTIF1 O O O Power recovery message is output After the Power recovery message 090122 001 before a PSU has recovered is output wait 60 seconds before removing power from another PSU RTIF1 O O O In a system connecting multiple hosts All the RCI hosts shall be powered on 090220 001 and one or more I O units with RCI the power on operation to one of those RCI hosts may not power on any of the RCI I O units RTIF1 O O O M3000 server M3000 server 090220 002 After replaced the motherboard unit If you have set the power interlocking the RCI power interlocking setting to a value other than the default restores to its default value replace the motherboar
54. d 6505921 O Correctable error on the system PCle For Oracle Solaris 10 8 07 or earlier bus controller generates an invalid this has been fixed in 120011 14 and fault 125369 05 Workaround Contact a qualified service engineer 6522433 O O After the CPU hardware error occurred For Oracle Solaris 10 8 07 or earlier the fmdump 1M command on the this has been fixed in patch 127127 11 domain may display an incorrect faulty component Workaround Check system status on XSCF 6527811 O O The showhardconf 8 command on For Oracle Solaris 10 8 07 or earlier the XSCF cannot display PCI card information that is installed in External I O Expansion Unit if the External I O Expansion Unit is configured using PCI hotplug this has been fixed in patch 128346 01 No workaround is available Chapter 3 Information About Software 57 TABLE 3 9 Oracle Solaris OS Issues Fixed in Oracle Solaris 10 5 08 Continued CR ID M4000 M8000 M3000 M5000 M9000 Description Workaround 6536564 6545143 O O showlogs 8 and showstatus 8 command on XSCF might report wrong I O component due to wrong diagnosis by Oracle Solaris Fault management Architecture when faults in I O devices occur There is a low probability that a system panic can occur during trap processing of a TLB miss for a user stack address The problem can occur if the user stack is unmapped concurrently with the user process executing a flush windows trap
55. d over 255 characters the SMTP address in the SMTP address an error results RTIF1 O During the domain operation after the Replace the motherboard unit only 081006 003 XSCF reset due to the XSCF unit failure When no failure found on the memory the hardware status shows you do not need to replace the memory Deconfigure in the status of CPU and memory RTIF1 O During the firmware update there Reset XSCF and use the 081006 004 might be the following output message flashupdate 8 command to retry the and a XSCF panic might occur kernel BUG in jffs2_do_read_inode at fs jffs2 readinode c XXX firmware update 34 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 TABLE 3 3 XCP Issues Fixed in Releases Earlier Than XCP 1110 Continued ID M3000 M5000 M9000 Description Workaround RTIF1 The network configuration on the XSCF Use the setnetwork r command on 081006 005 Web does not support the function the XSCF shell equivalent to the setnetwork r command And when you specified localhost or localdomain to the host name or the domain name the error message SessionID has expired appears RTIF1 The panic log on the XSCF Web might When the output is insufficient execute 081006 006 not be displayed from the top of the the showlogs panic command on the message XSCF shell RTIF1 The password 8 command indicates No workaround is available 081006 007 that the user operand is optional but Sp
56. d unit and then use the setpwrmode 1M command to set the power interlocking setting again M4000 M5000 M8000 M9000 servers M4000 M5000 M8000 M9000 servers Uae Nag alr A i o a value other than the default Aner replaced the XCF Hiat Tne RoI replace the XSCF unit and then use the power interlocking setting restores to its setpwrmode 1M command to set the default value f power interlocking setting again RTIF1 O O O Despite the normal status of ppp No workaround is available 090427 001 network interface for the XSCF to Oracle Solaris OS communication SNMP MIB notifies abnormal down status RTIF1 O O O After the XSCF reset or switching you No workaround is available 090427 002 cannot login to XSCF using the LDAP server Log in to active XSCF with initial account and execute the following command to re import the certificate chain setldap c lt remote file gt Chapter 3 Information About Software 37 TABLE 3 3 XCP Issues Fixed in Releases Earlier Than XCP 1110 Continued M4000 M8000 ID M3000 M5000 M9000 Description Workaround RTIF1 O After changed the SNMP configuration No workaround is available 090427 003 when the XSCF switching occurred the py case this event occurred the SNMP function may be disabled following command may restore the function setsnmp disable setsnmp disable run setsnmp disable twice setsnmp enable RTIF1 O O O In the setting of the LDAP server the To set 1
57. dress of an NTP server which is referring to the local clock does not correspond to the address of the XSCF internal local clock anymore and a server which is referring to the local clock can also be set as the NTP server of XSCF Notes on XSCF Web a Under the Windows 7 with Internet Explorer 8 0 or 9 0 environment XSCF Web does not support the use through the built in Administrator account m On Internet Explorer 8 0 when you move the on screen horizontal frame up or down to change the frame height and use the Monitor Msg Show Hide button the screen background color may turn black In this case click Refresh on the View menu or press F5 key to refresh the display to go back to the screen right after the login When you moved the on screen horizontal frame up or down to change the frame height do not use the Monitor Msg Show Hide button m M4000 M5000 M8000 M9000 servers XSCF Web does not support the External I O Expansion Unit Manager feature The M3000 server does not support External I O Expansion Unit M3000 M4000 M5000 servers Using the XSCF Web when you import XCP or update the firmware Session ID error may be displayed on the web browser And in the Autologout setting when you specify the timeout period as over 30 minutes Internal Server Error might be displayed when you perform the firmware update Please close the current browser and open the new browser to reconnect to XSCF Web M8000 M9000 servers Using t
58. e interpreter Xxxx ABORT Bus Error Fault Addr OXXXXXXXXX efdaemon xxx Wait pid xxxx status XXX WARNING IKP Unable to probe PCI leaf x x x Chapter 3 Information About Software 17 XCP Issues Fixed in XCP 1110 TABLE 3 2 lists XCP issues fixed in XCP 1110 TABLE 3 2 XCP Issues Fixed in XCP 1110 M4000 M8000 ID M3000 M5000 M9000 Description Workaround RTIF1 O O O XSCF sends Rst packets without AH This message can be safely ignored 110222 002 header when dscp disconnects resulting in false security vulnerability alarms The domain console may display this message ipsec_check_inbound_policy Policy Failure for the incoming packet not secure RTIF1 O O O Invoking setsnmp without options To view setsnmp usage options use 110526 001 results in segmentation fault setsnmp h RTIF1 O O O In the setemailreport 8 Do not specify these characters in the 111028 001 setsmtp 8 or setupplatform 8 email address command any of the following characters in the email address will result in an error L SSE 4 2 gt RTIF1 O O In case of connecting an External I O No workaround is available 111227 001 Expansion Unit a message watchdog timeout might be registered in an error log under the following conditions e Executes the switchscf 8 command on an M8000 M9000 server e Executes the reboot xscf 8 command on an M4000 M5000 server 18 SPARC Enterprise Mx000 Server
59. e Mx000 Servers Product Notes for XCP Version 1110 January 2012 Using the showdevices Command 67 Using the prtdiag Command to Identify Memory Size 68 Identifying Permanent Memory in a Target Board 68 4 Information About Hardware of M3000 Server 71 Notes and Limitations 71 Notes on Hardware RAID 71 Notes on Using the Hardware RAID 71 Notes on Building or Deleting the Hardware RAID 72 Notes on Operating the Hardware RAID 72 Notes on raidct1 1M Command 72 Notes on DVD Drive and Discs 73 Notes on the Use of USB Memory 73 Power Control and Operator Panel Mode Switch 73 Limitation for 1027A Z X1027A Z 74 Limitation for 4447A Z X4447A Z 74 Patches for Emulex PCI Express PCIe Adapters 74 Hardware RAID Function 75 Supported Conditions 75 Hardware Documentation Updates 75 Updates of the SPARC Enterprise M3000 Server Service Manual 76 Reactivating a Hardware RAID Boot Volume 76 5 Information About Hardware of M4000 M5000 Servers 81 Notes and Limitations 81 Notes on Server Installation 81 Notes on DVD Drive and Discs 81 Notes on the Use of USB Memory 82 Power Control and Operator Panel Mode Switch 82 Contents vii Notes on Air Filter 83 Limitation for 1027A Z X1027A Z 83 Limitation for 4447A Z X4447A Z 83 Patches for Emulex PCI Express PCIe Adapters 84 Hardware Issues and Workarounds 84 Sun Crypto Accelerator 6000 84 Hardware Documentation Updates 84 6 Information About Hardware of M8000 M9000 Servers 87 Notes and Limitatio
60. e Quad port Gigabit Ethernet Workaround UTP Low Profile Adapter X4447A Z Add the following line in e PCIe Dual 10 Gigabit Ethernet Fiber etc system and reboot the system XFP Low Profile Adapter X1027A Z set nxge nxge rx threshold hi 0 6584984 O On the M8000 M9000 servers For Oracle Solaris 10 8 07 or earlier busstat 1M command may cause this has been fixed in patch 127127 11 rebooting of domains No workaround is available Do not use busstat 1M command Check for the availability of a patch for this defect 6589546 O O prtdiag 8 command does not show For Oracle Solaris 10 8 07 or earlier all I O devices of the following this has been fixed in patch 127127 11 adapters e Sun StorageTek Enterprise Class 4Gb Workaround Dual Port Fibre Channel PCIe HBA Use prtd v for full output XSEFC402AF A ee ee e Sun StorageTek Enterprise Class 4Gb Single Port Fibre Channel PCIe HBA XSEFC401AF 60 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 Oracle Solaris OS Issues Fixed in Oracle Solaris 10 8 07 TABLE 3 10 lists issues that have been fixed in Oracle Solaris 10 8 07 OS You might encounter them in supported releases earlier than Oracle Solaris 10 8 07 Caution CR ID 6534471 Improper handling of large page in kernel memory may cause random panics Implement the workaround for CR ID 6534471 or check for the availability of a patch and install it immediately This bug has been fixed by
61. e Quad port Gigabit To avoid the defect do not install this Ethernet UTP Low Profile Adapter X4447A Z in slot 1 might cause other network devices to fail adapter in slot 1 Chapter 3 Information About Software 53 TABLE 3 8 Oracle Solaris OS Issues Fixed in Oracle Solaris 10 10 08 Continued M4000 M8000 CR ID M3000 M5000 M9000 Description Workaround 6614737 O O The DR deleteboard 8 and For Oracle Solaris 10 5 08 or earlier moveboard 8 operations might hang if this has been in patch 137111 01 any of the following conditions exist Workaround e A DIMM has been degraded Avoid performing DR operations if any e The domain contains system boards of the listed conditions exist with different memory size To determine whether the system contains degraded memory use the XSCF showstatus 8 command For sample output see Identifying Degraded Memory in a System on page 67 To determine whether the domain contains system boards with different memory sizes display the list of memory sizes using the XSCF showdevices 8 command or the prtdiag 8 command on the domain For sample of output see Identifying Different Memory Sizes in a System Board on page 67 If a DR command hangs reboot the domain to recover 6619224 O For Oracle Solaris domains that include This has been fixed in patch 137111 03 SPARC 64 VII processors a single A ret a a or Workaround more might hang for an extende f period of tim
62. e Switch Function Mode Switch Locked Service RCI Remote power on power off op Remote power on power off op erations are enabled erations are disabled APCS Automatic power on power off Automatic power on is disabled operations are enabled but power off remains enabled To use the RCI function see the SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers RCI Build Procedure and the SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers RCI User s Guide To use the APCS see the Enhanced Support Facility User s Guide for Machine Administration Automatic Power Control Function Supplement Edition Notes on Air Filter Fujitsu does not handle the air filter which is shown in the SPARC Enterprise M4000 M5000 Servers Service Manual as a product Limitation for 1027A Z X1027A Z For PCIe Dual 10 Gigabit Ethernet Fiber XFP Low Profile Adapter 1027A Z X1027A Z these maximum limits apply No more than two cards per a domain in an M4000 server No more than four cards per a domain in an M5000 server m Do not use these cards in an External I O Expansion Unit Limitation for 4447A Z X4447A Z For PCIe Quad port Gigabit Ethernet UTP Low Profile Adapter 4447A Z X4447A Z these maximum limits apply No more than four cards per a domain in an M4000 server No more than eight cards per a domain in an M5000 server Chapter 5 Information About Hardware of M4000 M5000 Servers 83 No more than four cards
63. e problem 6530178 O O DR addboard 8 command can hang For Oracle Solaris 10 11 06 this has Once problem is observed further DR been fixed in patch 120011 07 operations are blocked Recovery requires reboot of the domain Noworkatound is available 6530288 O O Ap_ld format may not be shown For Oracle Solaris 10 11 06 this has correctly by c gadm 1M command been fixed in patch 120011 07 No workaround is available 64 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 TABLE 3 10 Oracle Solaris OS Issues Fixed in Oracle Solaris 10 8 07 Continued M4000 M8000 CR ID M3000 M5000 M9000 Description Workaround 6534471 O O Systems may panic trap during normal For Oracle Solaris 10 11 06 this has operation been fixed in patch 125100 06 If a patch is not available disable the kernel large page sTLB programming In the file etc system change the variable heaplp_use_stlb to 0 set heaplp_use_stlb 0 6535564 O O PCI hot plug to PCI slot 0 1 or For Oracle Solaris 10 11 06 this has External I O Expansion Unit may fail been fixed in patch 120011 08 on XSB added by DR Workaround Use DR instead of PCI hot plug if need to add or remove PCI card on the XSB 6539084 O O Under Oracle Solaris 10 11 06 there isa No workaround is available low probability of a domain panic during reboot when the PCle Quad port Gigabit Ethernet UTP Low Profile Adapter X4447A Z is present in a domain 6539909 O O
64. e under certain unusual For Oracle Solaris domains that include ae SPARC 64 VII processors do not exceed situations Upon recovery the uptime h i a domain size of 256 virtual CPUs in a command will show extremely high i k single Oracle Solaris domain This load averages i ar means a maximum of 32 CPU chips ina single domain configuration maximum configuration for an M8000 server 6632549 O O fmd service on domain might fail to This has been fixed in patch 138050 01 maintenance mode after DR operations Workaround If fmd service fails issue the following commands on the domain to recover svcadm clear fmd 54 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 TABLE 3 8 Oracle Solaris OS Issues Fixed in Oracle Solaris 10 10 08 Continued M4000 M8000 CR ID M3000 M5000 M9000 Description Workaround 6660197 O O DR might cause the domain to hang if This has been fixed in patch 138397 01 either of the following conditions exist e A domain contains 256 or more Workaround CPUs 1 Set the following parameter in the e Memory error occurred and the system specification file DIMM has been degraded etc system set drmach drmach disable mcopy 1 2 Reboot the domain 6679370 O O O The following message may be output This has been fixed in patch 137137 09 on the console during the system Note Before adapting the patch booting the External I O Expansion
65. ecify the user operand to execute the will fail if a user operand is not password 8 command when you included when other options are specify other options specified RTIF1 SNMP trap host configuration changes Modify the SNMP setting 081006 011 are not valid until setsnmp disable xsCF gt setsnmp disable and setsnmp enable XSCF gt setsnmp enable RTIF1 Power failure at the commercial AC No workaround is available 081016 001 supply connector to the UPS does not send notification send trap RTIF1 In Internet Explorer 6 or 7 clicking on Log back into the browser interface and 081016 003 the Reset button then the OK button use the Backspace key to clear text in from the Settings Audit Add Policy the User text box of the pop up screen pop up screen will log the user out with instead of using the Reset button message Error Session Error Session ID has been expired RTIF1 The information related to the defined Use the showdc1 8 addboard 8 081030 001 LSB cannot be displayed on XSCF Web deleteboard 8 moveboard 8 Domain Configuration page with an account which has single domain privilege larger than DID15 In addition the operation for such LSB by XSB Config button cannot be performed command on the XSCF shell Chapter 3 Information About Software 35 TABLE 3 3 XCP Issues Fixed in Releases Earlier Than XCP 1110 Continued ID M4000 M8000 M3000 M5000 M9000 Description Workaround RTIF1
66. ed Patches Continued Server Processors XCP Oracle Solaris OS Required Patches M4000 M5000 SPARC64 VI 2 15 GHz 1040 or later M8000 M9000 SPARC64 VI 2 28 2 4 GHz Oracle Solaris 11 11 11 Oracle Solaris 10 8 11 Oracle Solaris 10 9 10 Oracle Solaris 10 10 09 Oracle Solaris 10 5 09 Oracle Solaris 10 10 08 Oracle Solaris 10 5 08 Oracle Solaris 10 8 07 Oracle Solaris 10 11 06 No patches required No patches required No patches required No patches required No patches required No patches required 137137 09 No patches required 118833 36 125100 04 or later 120068 03 or later 123839 07 or later 125424 01 or later 125075 01 or later 125670 02 or later M3000 SPARC64 VII 2 86 GHz 1101 or later Oracle Solaris 11 11 11 Oracle Solaris 10 8 11 Oracle Solaris 10 9 10 No patches required No patches required No patches required M3000 SPARC64 VII 2 75 GHz 1091 or later Oracle Solaris 11 11 11 Oracle Solaris 10 8 11 Oracle Solaris 10 9 10 Oracle Solaris 10 10 09 Oracle Solaris 10 5 09 Oracle Solaris 10 10 08 No patches required No patches required No patches required No patches required All patches contained in The PTF R10021 or latert All patches contained in The PTF R10021 or latert M3000 SPARC64 VII 2 52 GHz 1080 or later Oracle Solaris 11 11 11 Oracle Solaris 10 8 11 Oracle Solaris 10 9 10 Oracle Solaris 10 10 09 Oracle Solaris 10 5 09 Oracle Solaris 10 10
67. ed by the XSCF This CR effects Workaround only Oracle Solaris 10 5 09 Oracle o Use mdump 8 with its v option on Solaris 10 10 09 and an earlier version he Service P identify th of Oracle Solaris OS with patch 139555 Me Service Processor to identify the 08 faulty core Once identified use i psradm 1M on the domain to offline the core 6888928 O O O IPMP interface fails since probe packets This has been fixed in patch 142900 02 are not sent through that interface Problem occurs with M3000 M4000 M5000 M8000 M9000 servers running any Oracle Solaris release running IPMP with patch 141444 09 installed Workaround Disable probe based failure detection Oracle Solaris OS Issues Fixed in Oracle Solaris 10 10 09 TABLE 3 6 lists issues that have been fixed in Oracle Solaris 10 10 09 OS You might encounter them in supported releases earlier than Oracle Solaris 10 10 09 TABLE 3 6 Oracle Solaris OS Issues Fixed in Oracle Solaris 10 10 09 CR ID M4000 M8000 M3000 M5000 M9000 Description Workaround 6572827 O O O The prtdiag v command reports PCI This has been fixed in patch 141444 09 bus types incorrectly It reports PCI for PCI X leaf devices and UNKN for A Workaround legacy PCI devices No workaround is available Chapter 3 Information About Software 49 TABLE 3 6 Oracle Solaris OS Issues Fixed in Oracle Solaris 10 10 09 Continued M4000 M8000 CR ID M3000 M5000
68. ed due to reasons such as disk failure the error log might not be registered RTIF1 100331 001 O O When you use the sethttps 8 command to create the self CA Certificate Authority or a CSR with specifying only spaces for example in the e mail operand the HTTPS function might be disabled after XSCF reset RTIF1 100713 001 O O While the Oracle Solaris 10 OS is running if the occurrence of RED State Exception or watchdog reset or the execution of the reset xir command lead to the domain CPU reset the following message might be displayed on the console and the domain might hang up Failed to complete trap processing mid 0xXX RTIF1 100713 002 Though the mainline switch is on the showhardconf 8 command might wrongly display the PSU status as Breaker off or Input fail RTIF1 101019 001 O O When you start up a domain from a hard disk that is connected to the 8Gbps fibre channel card SE0X7F21F SE0X7F22F and if you specified an erroneous value after of the disk node the message of Fast Data Access MMU Miss might be displayed on the console and an error log of the TT 0x68 trap might be registered No workaround is available When you create the self CA or a CSR do not specify only spaces in the e mail operand No workaround is available When this problem occurred turn off the domain power and then turn on No workaround is available No workaround is available When
69. elated to hardware Each chapter describes each model The information which is common in all models is provided in all of these chapters As a result the description may be overlapped when you retrieve the hardware related information of multiple models x SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 Related Documentation All documents for your sever are available online at the following locations Manual Link Sun Oracle software related manuals http www oracle com documentation Oracle Solaris OS and so on Fujitsu documents Global Site http www fujitsu com sparcenter prise manual Fujitsu documents Japanese Site http jp fujitsu com platform serv er sparcenterprise manual Note Information in these product notes supersedes the information in the M3000 M4000 M5000 M8000 M9000 servers documentation set The following table lists titles of related documents Related SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers Documents Manual Code SPARC Enterprise M3000 Server Site Planning Guide SPARC Enterprise M4000 M5000 Servers Site Planning Guide SPARC Enterprise M8000 M9000 Servers Site Planning Guide SPARC Enterprise Equipment Rack Mounting Guide SPARC Enterprise M3000 Server Getting Started Guide SPARC Enterprise M4000 M5000 Servers Getting Started Guide SPARC Enterprise M8000 M9000 Servers Getting Started Guide SPARC Enterprise M
70. elated to the XCP version you are using Global Site http www fujitsu com sparcenterprise manual Japanese Site http jp fujitsu com platform server sparcenterprise manual This section includes Audience on page x How to Use This Document on page x Related Documentation on page xi Documentation Feedback on page xiv Audience This notes is written for experienced system administrators with working knowledge of computer networks and advanced knowledge of the Oracle Solaris Operating System Oracle Solaris OS How to Use This Document This document is intended for all models of the M3000 M4000 M5000 M8000 M9000 servers Read the appropriate related items depending on your server as shown in the table below Chapter of This Document M3000 M4000 M5000 M8000 M9000 Chapter 1 Software Requirements O O Chapter 2 XCP 1110 and XCP 1110 related Information O O O Chapter 3 Information About Software O O O Chapter 4 Information About Hardware of M3000 Server O Chapter 5 Information About Hardware of M4000 M5000 Servers O Chapter 6 Information About Hardware of M8000 M9000 Servers O Chapter 1 Chapter 2 and Chapter 3 provide the information related to firmware and software for all servers These chapters contain the descriptions which are specific to particular models too The relevant server name is clearly stated Chapter 4 Chapter 5 and Chapter 6 provide the information r
71. en fixed in patch 139570 01 Adapter UTP QGC amp Sun Dual 10 GigE Fiber XFP Low Profile Adapter XGF NICs might panic under high load conditions Workaround If possible use the card in x8 slot Otherwise there is no workaround Chapter 3 Information About Software 51 TABLE 3 7 Oracle Solaris OS Issues Fixed in Oracle Solaris 10 5 09 Continued M4000 M8000 CR ID M3000 M5000 M9000 Description Workaround 6689757 O O O Sun Dual 10 GigE Fiber XFP Low This has been fixed in patch 139570 01 Profile Adapter XGF with a single or improperly installed XFP optical Workaround t i ight the followi ea Ae eaael lt lt a Check and make sure that both XFP error to show on the console i i i _ optical transceivers are firmly seated in ThE ZFR optical eranscel Ver 28 ihe housing Do not mix INTEL and broken or mresing Sun XFP optical transceivers in the same Adapter Do NOT plumb a port with the ifconfig command if the port does not contain an XFP optical transceiver or it contains one but the transceiver is not in use 6725885 O cfgadm will display non existent This has been fixed in patch 140401 01 M3000 system boards SB1 to SB15 The cfgadm output for SB1 SB15 can be ignored Oracle Solaris OS Issues Fixed in Oracle Solaris 10 10 08 TABLE 3 8 lists issues that have been fixed in Oracle Solaris 10 10 08 OS You might encounter them in supported releases earlier than Oracle Solaris 10 10 08
72. failure an error log of FRU UNSPECIFIED might be registered If setpasswordpolicy r is set to 0 existing XSCF users are unable to change their password and get the error message password Operation failed No workaround is available Specify the abbreviation of time zone and the name of Daylight Saving Time in seven letters or less Please refresh the display No workaround is available Use XSCF Web This error log can be safely ignored No workaround is available Do not execute the command setpasswordpolicy r 0 16 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 TABLE 3 1 Known Issues and Workarounds in XCP 1110 Continued M4000 M8000 ID M3000 M5000 M9000 Description Workaround RTIF1 O O M4000 M5000 servers M4000 M5000 servers 111005 001 When the system board is mounted No workaround is available with the onboard I O device if you use the addboard 8 or moveboard 8 command to add or move it by DR operation may fail M8000 M9000 servers M M 20007 M2000 Servers No workaround is available When the system board is mounted with one or more PCI cards if you use the addboard 8 or moveboard 8 command to add or move it by DR operation may fail However when it is mounted with the TOUA card only this event does not occur In either case the following message appears on the destination domain console of the system board addition or mov
73. geTek Enterprise Class 4Gb Dual Port Fibre Channel PCle HBA XSEFC402AF m Sun StorageTek Enterprise Class 4Gb Single Port Fibre Channel PCIe HBA XSEFC401 AF Hardware Issues and Workarounds DVD Drives and cfgadm The Solaris cEgadm 1M command does not always unconfigure a DVD drive from a domain on the M8000 M9000 servers Chapter 6 Information About Hardware of M8000 M9000 Servers 89 Disable the Volume Management Daemon vold before unconfiguring a DVD drive with the c gadm 1M command To disable vold stop the daemon by issuing the command etc init d volmgt stop After the device has been removed or inserted restart the daemon by issuing the command etc init d volmgt start Sun Crypto Accelerator 6000 If you are not using the correct version of the Sun Crypto Accelerator SCA 6000 driver hot plug operations on SCA 6000 can cause the M8000 M9000 servers to panic or hang Version 1 1 of the SCA6000 driver and firmware supports hot plug operations after the required bootstrap firmware upgrade has been performed Version 1 0 of the SCA6000 driver does not support hot plug and should not be used Hardware Documentation Updates This section contains late breaking hardware information that became known after the documentation set was published and corrections in the M8000 M9000 servers hardware documentation TABLE 6 2 lists known documentation updates TABLE 6 2 Hardware Documentation Updates Title Page
74. he XSCF Web when you import XCP or update the firmware Session ID error may be displayed on the web browser And Internal Server Error might be displayed when you perform the firmware update Please close the current browser and open the new browser to reconnect to XSCF Web a When you use the XSCF Web under the Internet Explorer 6 or 7 or Firefox 2 environment if a plug in such as the search tool installed with the browser remove the plug in or disable the pop up blocking When you use the XSCF Web under the Internet Explorer 8 or 9 or Firefox 3 6 8 or 9 environment if a plug in such as the search tool installed with the browser disable the pop up blocking m When you use XSCF Web under the Firefox 3 6 8 or 9 environment and attempt to log in to XSCF you may be prompted by the browser to save the login ID password In this case do not save the login ID password If you save the login ID password the stored data can be displayed unexpectedly on the LDAP SMTP and REMCS web pages Chapter 2 XCP 1110 and XCP 1110 related Information 9 Use one of two settings described below to disable the browser s ID password remember function a Disable the entire browser ID password remember function Click on the Tools menu and select Preferences On the Security panel see Passwords and uncheck the Remember passwords for sites checkbox a Designate the XSCF Web address as an exception to the ID password save operation C
75. hen running For Oracle Solaris 10 8 07 this has been hotplug cfgadm 1M and DR fixed in patch 127741 01 operations addboard 8 and deleteboard 8 on the following Wo workaround is available adapters e PCIe Quad port Gigabit Ethernet UTP Low Profile Adapter X4447A Z e PCIe Dual 10 Gigabit Ethernet Fiber XFP Low Profile Adapter X1027A Z 6551356 O O The system panics when running For Oracle Solaris 10 8 07 this has been hotplug cfgadm 1M to configure a fixed in patch 127741 01 previously unconfigured adapter The message WARNING PCI Expansion Workaround ROM is not accessible will be seen on the console shortly before the Fetf rm efgadm ee dieconnectto f completely remove the card After system panic The following cards are ae ffected by this defect waiting at least 10 seconds the card affected by this defect ae may be configured back into the e PCIe Quad port Gigabit Ethernet domain using the cfgadm c UTP Low Profile Adapter X4447A Z configure command e PCIe Dual 10 Gigabit Ethernet Fiber XFP Low Profile Adapter X1027A Z 6559504 O O Messages of the form nxge NOTICE For Oracle Solaris 10 8 07 this has been nxge_ipp eccue valid check rd_ptr nnn wr_ptr nnn will be observed on the console with the following adapters e PCIe Quad port Gigabit Ethernet UTP Low Profile Adapter X4447A Z e PCIe Dual 10 Gigabit Ethernet Fiber XFP Low Profile Adapter X1027A Z fixed in patch 127741 01
76. hen you turn on AC power or when Before turning on AC power or you execute the rebootxscf 8 executing the rebootxscf 8 command you may become unable to command please confirm that XSCF log in to XSCF and your press on the LAN has been correctly connected and POWER switch on the operator panel linked up may fail to turn on the power In case the situation in question occurred please turn off the power of all domains and then execute the system power off on To turn on the power that you turned off wait at least 30 seconds before power on eric M8000 M9000 servers When you turn on AC power or when Before turning on AC power or you execute the rebootxscf 8 or executing the rebootxscf 8 or switchsc 8 command either of the A switchscf 8 command please following situations may occur confirm that XSCF LAN has been eF ollowing error message gets correctly connected and linked up registered in the error log the status In case the situation in question becomes Faulted and the standby d olease take either of the XSCF becomes unable to start ee a ti Device error on serial T A O AE HEN A 4 Aterconnacti ni between e Use the replacefru 8 command to XSCFUs reattach the standby XSCF unit e You become unable to log in to XSCF e Turn off the power of all domains and your press on the POWER switch and then execute the system power on the operator panel can t turn on off on To turn on the power that you the power tur
77. in an External I O Expansion Unit two per PCIe I O boat Patches for Emulex PCI Express PCIe Adapters The following Emulex PCle adapters require drivers supplied in patch 120222 26 a Sun StorageTek Enterprise Class 4Gb Dual Port Fibre Channel PCIe HBA XSEFC402AF m Sun StorageTek Enterprise Class 4Gb Single Port Fibre Channel PCIe HBA XSEFC401 AF Hardware Issues and Workarounds Sun Crypto Accelerator 6000 If you are not using the correct version of the Sun Crypto Accelerator SCA 6000 driver hot plug operations on SCA 6000 can cause the M4000 M5000 servers to panic or hang Version 1 1 of the SCA6000 driver and firmware supports hot plug operations after the required bootstrap firmware upgrade has been performed Version 1 0 of the SCA6000 driver does not support hot plug and should not be used Hardware Documentation Updates This section contains late breaking hardware information that became known after the documentation set was published and corrections in the M4000 M5000 servers hardware documentation 84 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 TABLE 5 2 lists known documentation updates TABLE 5 2 Hardware Documentation Updates Title Page Number Update SPARC Enterprise M4000 M5000 Servers Installation Guide 2 4 3 2 3 15 The following Caution will be added Caution Ensure that the circuit breaker is off when installing or removing AC p
78. karounds depending on the mode appear on the domain console at the domain start and you may fail to perform time synchronization ntpdate xx suitable for synchronization no server which has been set in the xntpd of the domain Note In case of step mode the time correction induces the time step When the time step occurred it may affect the applications running on the domain e In case of step mode Specify the w option to execute the ntpdate 1M command Until it succeeds in synchronizing with the NTP server the ntpdate command retry continues at regular intervals In the retries the message which indicates that it failed to synchronize with the NTP server can be safely ignored When the synchronization completed the time will be corrected to the time of the NTP server e In case of slew mode Execute the ntpdate 1M command without specifying the w option In slew mode the time variance from the NTP server will be corrected at 0 5 ms second intervals The message which indicates that it failed to synchronize with the NTP server can be safely ignored Before the time completely corrected there remains a time variance between the NTP server and the domain Chapter 3 Information About Software 31 TABLE 3 3 XCP Issues Fixed in Releases Earlier Than XCP 1110 Continued M4000 M8000 ID M3000 M5000 M9000 Description Workaround RTIF1 O O M4000 M5000 servers M4000 M5000 servers 080325 001 W
79. lable at this time 070824 008 when you select an undefined Domain ID the Configuration Policy remains as the content which previously displayed RTIF1 O On the System Board Configuration None available at this time 070824 009 screen when you execute Detail it is displayed as if the CPUM and the memory of MBU are all mounted on the PSB 0 side And in the detail display of PSB 0 memory is displayed as 22 2 RTIF1 O O While using Firefox 2 in the From the Menu select the Domain 070824 011 Configuration policy setting on the Configuration page again Domain Configuration screen when you specify a domain which is in operation an error display pop up appears When you click on the Back button on this error display pop up and click on the Cancel button on the inquiry screen to re display the data the system remains in the error message screen RTIF1 O CLIs executed in Standby XSCF should Only the following CLIs can be 070904 001 display executed on the Standby XSCF Permission denied snapshot 8 switchscf 8 Do not attempt to run any other CLI on the Standby XSCF Such attempts will report various errors RTIF1 O O When the snapshot CLI attempts to Do not attempt to use write protected 070904 002 write to a USB stick that has write USB devices for collecting snapshot protect set results in an I O error Chapter 3 Information About Software 23 TABLE 3 3 XCP Issues Fixed in Releases Earlier Than XCP 1110 Co
80. le ou de Fujitsu Limited ou des soci t s affili es de l une ou l autre entit Ce document ainsi que les produits et technologies qu il d crit peuvent inclure des droits de propri t intellectuelle de parties tierces prot g s par copyright et ou c d s sous licence par des fournisseurs Oracle et ou ses soci t s affili es et Fujitsu Limited y compris des logiciels et des technologies atives aux polices de caract res Conform ment aux conditions de la licence GPL ou LGPL une copie du code source r gi par la licence GPL ou LGPL selon le cas est disponible sur demande par l Utilisateur final Veuillez contacter Oracle et ou ses soci t s affili es ou Fujitsu Limited Cette distribution peut comprendre des composants d velopp s par des parties tierces Des parties de ce produit peuvent tre d riv es des syst mes Berkeley BSD distribu s sous licence par l Universit de Californie UNIX est une marque d pos e aux Etats Unis et dans d autres pays distribu e exclusivement sous licence par X Open Company Ltd Oracle et Java sont des marques d pos es d Oracle Corporation et ou de ses soci t s affili es Fujitsu et le logo Fujitsu sont des marques d pos es de Fujitsu Limited Toutes les marques SPARC sont utilis es sous licence et sont des marques d pos es de SPARC International Inc aux Etats Unis et dans d autres pays Les produits portant la marque SPARC reposent sur des architectures d velopp es
81. lick on the Tools menu and select Preferences On the Security panel see Passwords and check the Remember passwords for sites checkbox Then on the dialog for the ID password saving which appears in the login attempt to XSCF click the Never for This Site button As a result the XSCF Web address will be registered in the Exceptions list to the ID password save operation and the dialog to prompt the ID password saving will no longer be displayed in the subsequent login attempts to XSCF Miscellaneous Notes and Limitations Caution M4000 M5000 M8000 M9000 servers For dynamic reconfiguration DR and hot plug issues see Oracle Solaris OS Issues and Workarounds on page 42 m M4000 M5000 M8000 M9000 servers The following functions displaying the power consumption is not supported on M4000 M5000 M8000 M9000 servers a power operand of the showenvironment 8 command a XSCF Web Note Invalid values will be displayed by executing the commands or menu SNMP Agent Function obtains invalid values of power consumption m M4000 M5000 servers The M4000 M5000 servers are cold service machines Hot swapping of the CPU module CPUM memory board MEMB I O unit IOU or XSCF unit is not supported M8000 M9000 servers Do not use the internal CD RW DVD RW drive unit and the TAPE drive unit at the same time m The log archive feature by the setarchiving 8 and the showarchiving 8 commands and the Log
82. lue again a During the server powering on or powering off or for a while after the power on or power off complete a During the active replacement of power supply unit or for a while after the active replacement complete The figures on the airflow indicator represent the volume of air exhausted from the server The figures of peripheral devices are not included Notes on NTP Server We recommend the domain to use the XSCF Unit as NTP server In this case pay attention to the following points a XSCF must be connected to an external NTP server a When you connect one or more NTP servers in addition to XSCF connect the same NTP server as XSCF is using For details on NTP server contact a service engineer For details on NTP settings refer to the SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers XSCF User s Guide Notes on the NTP Server Referring to the Local Clock When the NTP server which XSCF refers to is referring to the server s own system time local clock and when the address of 127 127 1 0 is set to that local clock time synchronization in XSCF might fail The address of the XSCF s own local clock is fixed to 127 127 1 0 On the other hand when the address of the local clock of the NTP server which XSCF refers to is set to 127 127 1 0 the address of the clock source refid has the same value as the address of the XSCF s own local clock An NTP server like this is excluded from the target of XSCF time sy
83. mited up to 20 characters Do not fail to set Confirm Password which is a field must be entered None available at this time Set the correct user name or execute the Cancel button to close the pop up screen None available at this time To specify a user name of 20 characters or more use the adduser 8 command 26 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 TABLE 3 3 XCP Issues Fixed in Releases Earlier Than XCP 1110 Continued ID M4000 M8000 M3000 M5000 M9000 Description Workaround RTIF1 070914 016 RTIF1 070914 017 RTIF1 070914 018 RTIF1 070914 019 RTIF1 070914 020 RTIF1 070914 021 O O On the XSCF Web when you select LDAP to perform the LDAP configuration if you execute Save while the LDAP Search TImeout remains as its default value 0 it results in LDAP Configuration Update Failed Save LDAP Configuration Data failed and the setting can t be stored On the XSCF Web when you select LDAP and input the LDAP Search Timeout with a value which exceeds the maximum 2147483647 seconds it doesn t result in parameter error On the XSCF Web when you use a user account without an appropriate privilege to select LDAP and execute the Delete button it results in a privilege error but the configuration information which has been displayed will be cleared and seems as if deleted The CLI showldap c which displ
84. n Using the showdevices Command 1 Log in to XSCF Chapter 3 Information About Software 67 2 Type the following command XSCF gt showdevices d domain_id The following example displays 00 0 has 64GB of memory while the other system boards have 16GB XSCF gt showdevices d 1 Memory board perm base domain target deleted remaining DID XSB mem MB mem MB address mem MB XSB mem MB mem MB 01 00 0 63680 O 0x0000004000000000 260288 01 03 0 16384 7384 0x0000034000000000 260288 01 03 1 16384 O 0x0000030000000000 260288 01 03 2 16384 O 0x000002c000000000 260288 01 03 3 16384 O 0x0000028000000000 260288 Using the prtdiag Command to Identify Memory Size m On the domain execute the prtdiag command prtdiag The following example displays different memory sizes prtdiag Memory Configuration wore eee ee ee ee ee ee ee eee Memory Available Memory DIMM of Mirror Interleave LSB Group Size Status Size DIMMs Mode Factor 00 A 32768MB okay 2048MB 16 no 8 way 00 B 32768MB okay 2048MB 16 no 8 way 03 A 8192MB okay 2048MB 4 no 2 way 03 B 8192MB okay 2048MB 4 no 2 way 04 A 8192MB okay 204 8MB 4 no 2 way 04 B 8192MB okay 2048MB 4 no 2 way 05 A 8192MB okay 2048MB 4 no 2 way 05 B 8192MB okay 2048MB 4 no 2 way 06 A 8192MB okay 2048MB 4 no 2 way Identifying Permanent Memory in a Target Board 1 Log in to XSCF 68 SPARC Enterprise Mx000 Servers Product Notes for
85. n you specify the domain ID or Specify the available domain ID or XSB 070914 023 XSB number which are not supported number on the server on the server there appears the parameter error message RTIF1 O O When you display the physical tree on None available at this time 070914 024 the XSCF Web the warning mark is displayed on the link card for External I O expansion unit RTIF1 O O The XSCFU cannot act as a reliable NTP All domains should be configured to 070914 026 source for domains use a NTP source other than the XSCFU RTIF1 O O On the Domain Configuration screen When you define the Domain 070915 001 when you newly define the Domain Component List use CLI Component List the parameter error may be displayed RTIF1 O When the server is being installed and Turn off the system AC power then 071011 001 the mainline switch is turned on for the turn it on again first time these error messages might be displayed XSCFU hang up is detected XSCF process down detected DB synchronization timeout RTIF1 O O The XSCF firmware monitors itself and No workaround is available Allow the 071102 001 if it detects any inconsistencies it forces XSCF Unit to finish rebooting It returns an XSCF reboot to normal operation within approximately 5 minutes RTIF1 O O The snmp daemon might quit To restart the snmp daemon issue the 071102 002 command setsnmp enable RTIF1 O DR operations might fail with a Do not fail to execute the diagnosis in 071
86. nated server or later m If the specified timeout is too brief for the configuration the login process or retrieval of user privilege settings could fail In such case specify larger value for the timeout and then execute again Notes on LDAP SSL If the specified timeout is too brief for the configuration the login process or retrieval of user privilege settings could fail In such case specify larger value for the timeout and try again Notes on Power Consumption Monitoring Function M3000 Server m The amount of power consumption might not be indicated correctly in the MIB information in the showenvironment power command output and on the XSCF Web in the following cases and you should wait for one minute and check the value again a During the server powering on or powering off or for a while after the power on or power off complete a During the active replacement of power supply unit or for a while after the active replacement complete m The figures on the power consumption monitoring function represent the dissipation power from the server The figures of peripheral devices are not included 6 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 Notes on Airflow Indicator The amount of exhaust air might not be indicated correctly in the MIB information in the showenvironment air command output and on the XSCF Web in the following cases and you should wait for one minute and check the va
87. nchronization You can execute the showntp 1 command to refer to the address of the NTP server s own clock source which is set in XSCF and the address of the XSCF s own local clock Chapter 2 XCP 1110 and XCP 1110 related Information 7 XSCF gt showntp 1 remote refid st t when poll reach delay offset jitter 192 168 1 2 LOCAL 0 3 u 10 1024 377 0 000 0 000 0 000 127 127 1 0 LOCL 5 1 28 64 377 0 000 0 000 0 008 Of the two NTP server outputs the upper 192 168 1 2 indicates the NTP server which is set by using the setntp 8 command The refid is LOCAL 0 which means that the local clock which has the address of 127 127 1 0 is set to the clock source of this NTP server On the other hand the lower indicates the XSCF s own local clock The address of the XSCF s own local clock is fixed to 127 127 1 0 Due to this the NTP server 192 168 1 2 is excluded from the target of XSCF time synchronization which results in the XSCF synchronizes with its own local clock With any of the following measures to avoid the trouble time can be correctly synchronized with the NTP server which is set by using the setntp 8 command Change the clock source that the NTP server being set in XSCF refers to Use the showntp 1 command and check the clock source of the NTP server which is set in XSCF An NTP server which indicates the refid of LOCAL 0 in the output is referring to the local clock which has the address of 127 127 1 0
88. ned off wait at least 30 seconds before power on RTIF1 O O Following a dynamic reconfiguration The MSG ID assigned to the error 080404 001 operation using the XSCF commands displayed and the actual behavior may deleteboard 8 and addboard 8 not be consistent and reset or you might see I O channel degradation degradation may not occur Contact a resulting in error messages and entries qualified service engineer and give the in the corresponding ereport error code that displayed by using the If you run into this problem the showlogs error command mdump 8 command will report the following error by mistake ereport chassis SPARCEnterpris e asic ioc ch leaf fe 32 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 TABLE 3 3 XCP Issues Fixed in Releases Earlier Than XCP 1110 Continued M4000 M8000 ID M3000 M5000 M9000 Description Workaround RTIF1 O O When you use the command Always set a password of at least eight 080404 002 setsnmpusm passwd to set a characters password if you set a password of fewer than eight characters a segmentation fault occurs RTIF1 O O When you specify Localhost to the Do not specify Localhost to the 080512 001 hostname of the sethostname 8 hostname of the sethostname 8 command and reset XSCF by using the command applynetwork 8 and the rebootxscf 8 commands a process goes down in XSCF RTIF1 O When the NTP setting are enabled a This message
89. nning Oracle VTS Step 2 The following description will be deleted For details on items to be diagnosed see the Oracle VTS Test Reference Manual SPARC Enterprise M3000 4 3 The following note will be added Server Service Manual 6 2 Note To activate a hardware RAID boot volume after replacing the MBU of an M3000 server with SPARC64 VII processors see Appendix F Reactivating a Hardware RAID Boot Volume on page F 1 Appendix F The procedures for reactivating a hardware RAID boot volume will be added See Reactivating a Hardware RAID Boot Volume on page 76 for detail Updates of the SPARC Enterprise M3000 Server Service Manual The following information supersedes the information in the SPARC Enterprise M3000 Server Service Manual Reactivating a Hardware RAID Boot Volume This appendix explains how to reactivate a hardware RAID boot volume after replacing the MBU of an M3000 server with the SPARC64 VII processors Non boot RAID volumes can be reactivated after booting with the Oracle Solaris raidct1 command The MBU contains the RAID controller When the MBU is replaced the disks comprising the RAID boot volume must be reactivated to be able to boot This is done from OBP via the OBP command activate volume 76 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 1 Confirm that the RAID volume is no longer listed 0 ok probe scsi all pci 0 600000 pci 0 pci 0 scsi od MPT Version 1 05 Fi
90. ns 87 Notes on DVD Drive and Discs 87 Notes on the Use of USB Memory 87 Power Control and Operator Panel Mode Switch 88 Limitation for 1027A Z X1027A Z 89 Limitation for 4447A Z X4447A Z 89 Patches for Emulex PCI Express PCIe Adapters 89 Hardware Issues and Workarounds 89 DVD Drives and cfgadm 89 Sun Crypto Accelerator 6000 90 Hardware Documentation Updates 90 Miscellaneous Information 92 Cabinet Stabilization Measures 92 Method of Securing the Cabinet to the Floor Surface 92 viii SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 Preface These product notes contain important and late breaking information about the SPARC Enterprise M3000 M4000 M5000 M8000 M9000 server hardware software firmware and documentation covering the latest XSCF Control Package XCP release Some references to server names and document names are abbreviated for readability For example if you see a reference to the M9000 server note that the full product name is the SPARC Enterprise M9000 server And if you see a reference to the XSCF Reference Manual note that the full document name is the SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers XSCF Reference Manual Note Once an XCP version newer than the XCP version supported by this manual is released only the manuals related to the new XCP version are subsequently updated You must therefore check the manuals for the latest XCP version in addition to those r
91. ntinued M4000 M8000 ID M3000 M5000 M9000 Description Workaround RTIF1 O O An incorrect domain state is reported No workaround is available This is 070904 003 After the command sendbreak 8 to expected behavior of the sendbreak 8 domain is issued operation showdomainstatus 8 continues to show the state as Running when the domain is actually at ok prompt RTIF1 O O Time can t be synchronized with the Check the stratum value of the NTP 070904 005 NTP server server The stratum value of XSCF is 5 The NTP server which the XSCF refers to must be a server on which the stratum value is smaller than 5 When you changed the NTP server to refer to reboot the XSCF When the stratum value has been set correctly and the time can t be synchronized use the showntp 8 command to check the jitter value to be displayed If this value is large please reboot the XSCF RTIF1 O O While executing the domain power on Execute the domain reset one more 070904 006 domain reset or DR in case the XSCF time or power off the domain and then reset occurred the process may be power on again aborted in some or all of the XSB RTIF1 O O If an invalid SMTP server is configured Wait for the CLI to complete The rest of 070912 001 a subsequent attempt to disable e mail the system will function normally service using the setemailreport during this time CLI may block for up to 30 minutes e The CLI can also be aborted by C Note that
92. or cfgadm Component system is busy error 6481002 O O O Installing the Oracle Solaris OS from the If you are using a Sun PCI E Dual network using certain PCI Express cards may cause a panic Gigabit Ethernet MMF Adapter or a Sun PCI E Dual Gigabit Ethernet UTP Adapter do not install the Oracle Solaris OS using either of these cards Instead use other network devices such as the onboard Gigabit Ethernet or another network device Chapter 3 Information About Software 43 TABLE 3 4 Oracle Solaris OS Issues and Workarounds for All Supported Releases Continued CR ID M3000 M4000 M9000 Description Workaround 6515648 6516135 6519290 6522017 O Replumb Failed error appears when dr 0 SB1 memory fails Ap_Id format and devices may not be shown correctly by cf gadm 1M Large amounts of I O on swap devices can cause the system to appear hung by overwhelming the I O system The amount of I O required can be generated through a number of ways eg memory shortage heavy use of tmp etc DR and ZFS may not be used in the same domain Once the DR operation is complete it can be plumbed up manually Example steps to re plumb the interface manually ifconfig interface plumb XXX XXX XXX XXX netmask broadcast up ifconfig interface group group name ifconfig interface addif XXX XXX XXX XXX failover deprecated up This workaround assumes that the etc hostname interface file is
93. ors an incorrect value of DC power supply model Permitted AC power consumption will be displayed with 470 W RTIF1 O O O From the OpenBoot PROM prompt In case this event occurred redo the 110523 001 ok when you use the nvalias settings of any devalias which is command and try setting a devalias to the environmental variable nvramrc it may fail with the message Can t create new alias because nvramre is full already defined in the environmental variable nvramrc by using the nvalias command Then in order to set the failed devalias execute the nvalias command once again Chapter 3 Information About Software 41 Oracle Solaris OS Issues and Workarounds This section contains information about Oracle Solaris OS issues TABLE 3 4 TABLE 3 5 TABLE 3 6 TABLE 3 7 TABLE 3 8 TABLE 3 9 and TABLE 3 10 list issues you might encounter depending upon which Oracle Solaris OS release you are using Oracle Solaris Issues and Workarounds for All Supported Releases TABLE 3 4 lists Oracle Solaris OS issues that you might encounter in any supported release of Oracle Solaris OS TABLE 3 4 Oracle Solaris OS Issues and Workarounds for All Supported Releases M4000 M8000 CR ID M3000 M4000 M9000 Description Workaround 6344060 O A lot of following ereports are outputted when both interfaces bge1 and bge2 are in use ereport io device badint_limit ereport io service lost This issue is caused on the M3000 server
94. ory in which the data stored from the data security viewpoint We do not provide guarantees to every USB memory from any manufacturers that currently on the market against its connectivity to XSCF and proper operation Depending on the USB memory in use defects such as the XSCF firmware error or reset may occur In case such defects occurred stop the use of USB memory immediately To connect the USB memory to the USB port for XSCF connect the USB memory directly to the USB port If connected via USB hub or USB extension cables it may cause errors Power Control and Operator Panel Mode Switch Note Before using the RCI function see Notes on RCI Function on page 13 When you use the remote power control utilizing the RCI function or the automatic power control system APCS you can disable this remote power control or the APCS by setting the mode switch to Service mode on the operator panel Disabling these features ensures that you do not unintentionally switch the system power on or off during maintenance Note that system power off with the APCS cannot be disabled with the mode switch Therefore be sure to turn off automatic power control via APCS before starting maintenance 82 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 If you switch the mode while using the RCI or the automatic power control the system power is controlled as follows TABLE 5 1 RCI and APCS Control with Mod
95. ower cords in order to avoid damage to the PSU or system B type plug in the Note in 2 2 2 Cable Connections should be substituted with the plug with lock function The following step 2 will be added 2 Verify that the input power breaker is off The step 1 Confirm that the system is powered on in 3 4 2 Checking the Dual Power Feed will be changed to Confirm that the system is powered on by checking the output of the showdomainstatus a command from the XSCF Shell Chapter 5 Information About Hardware of M4000 M5000 Servers 85 86 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 CHAPTER 6 Information About Hardware of M8000 M9000 Servers This section describes the special instructions and the issues about the M8000 M9000 servers hardware Notes and Limitations on page 87 Hardware Issues and Workarounds on page 89 Hardware Documentation Updates on page 90 Miscellaneous Information on page 92 Notes and Limitations Notes on DVD Drive and Discs See the Notes on DVD Drives and Discs in SPARC Enterprise on the website below before using the CD DVD discs in the standard DVD drive mounted in this server http www fujitsu com sparcenterprise manual Notes on the Use of USB Memory To execute the dumpconfig 8 restoreconfig 8 or snapshot 8 command if you specify USB memory as the destination to store data prepare the USB memory as a
96. pci 0 scsi o MPT Version 1 05 Firmware Version 1 31 00 00 Target 0 Volume 0 Unit 0 Disk LSILOGICLogical Volume 3000 585805824 Blocks 299 GB Target 4 Unit 0 Removable Read Only device TEAC DV W28S V J 0B SATA device PhyNum 4 0 ok boot Boot device disk a File and args SunOS Release 5 10 Version Generic _142909 17 64 bit Copyright c 1983 2010 Oracle and or its affiliates All rights reserved raidctl S O LST _1068E cotodo 2 0 0 0 0 1 0 1 SYNC 0 0 0 GOOD 0 1 0 GOOD 78 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 raidctl Volume cotodo Aug 18 mptoO Aug 18 Aug 18 mptoO Aug 18 Aug 18 mpto Aug 18 1 cOt0d0 Sub 21 21 21 2T 21 21 raidctl Volume cotodo 07 07 O7 07 207 07 1 Sub 02 02 02 02 02 02 m3000 m3000 m3000 m3000 m3000 m3000 c0t0ddo Size Stripe Size 279 3G N A 279 3G 279 3G Status Cache RAID Level SYNC OFF RAID1 GOOD GOOD scsi pci 0 600000 pci 0 pci 0 scsi od Physical disk target 1 is online scsi pci 0 600000 pci 0 pci d0 scsi od Volume 0 is enabled resyncing optimal scsi pci 0 600000 pci 0 pci d0 scsi od Volume 0 is enabled optimal Size Stripe Size Status Cache RAID Level OPTIMAL OFF RAID1 GOOD GOOD Chapter 4 Information About Hardware of M3000 Server 79 80 SP
97. prompt 6531036 O O O The error message network No workaround is available This initialization failed appears message can be safely ignored repeatedly after a boot net installation 6532215 O O O volfs or dscp service may fail when Restart the service if the failure is domain is booted observed To avoid the problem issue the following commands svc platform sun4u dscp defau lt Method svcecfg s dscp setprop lib svc method svc dscp start timeout_seconds count start failed with exit status 300 95 svcecfg s volfs setprop start timeout_seconds count svc system filesystem volfs d 300 efault Method or service exit svcadm refresh dscp timed out Killing contract svcadm refresh volfs Bos 6565553 O O DR deleteboard 8 and No workaround is available 6611966 moveboard 8 operations might fail Try DR operations again 6674266 Example for messages on domain drmach WARNING Device driver failure pci dcs lt XXXX gt config_change_state Hardware specific failure unconfigure SB1 Device driver failure pei 6588650 O O On occasion the system is unable to DR No workaround is available after an XSCF failover or XSCF reboot Chapter 3 Information About Software 45 TABLE 3 4 Oracle Solaris OS Issues and Workarounds for All Supported Releases Continued M4000 M8000 CR ID M3000 M4000 M9000 Description Workaround 6589644 O After added the system board by DR The console can be recovered by when the s
98. r 7 Notes on NTP Server 7 Notes on the NTP Server Referring to the Local Clock 7 Notes on XSCF Web 9 Miscellaneous Notes and Limitations 10 XCP 1110 Issues and Workarounds 11 Updating toXCP 1110 12 Resetting the XSCF Firmware 12 Updating from a Version Earlier Than XCP 1050 M8000 M9000 Servers 12 Updating from a Version Earlier Than XCP 1070 M8000 M9000 Servers 12 3 Information About Software 13 Notes and Limitations 13 Notes on RCI Function 13 Notes on Remote Maintenance 14 Before Setting the Remote Maintenance Service 14 Enabling and Disabling the REMCS Agent Function 14 The Timezone Setting for REMCS Agent Function 14 XCP Issues and Workarounds 14 Known Issues and Workarounds in XCP 1110 15 XCP Issues Fixed in XCP 1110 18 XCP Issues Fixed in Releases Earlier Than XCP 1110 19 Oracle Solaris OS Issues and Workarounds 42 Oracle Solaris Issues and Workarounds for All Supported Releases 42 Oracle Solaris OS Issues Fixed in Oracle Solaris 109 10 48 Oracle Solaris OS Issues Fixed in Oracle Solaris 1010 09 49 Oracle Solaris OS Issues Fixed in Oracle Solaris 105 09 51 Oracle Solaris OS Issues Fixed in Oracle Solaris 1010 08 52 Oracle Solaris OS Issues Fixed in Oracle Solaris 105 08 56 Oracle Solaris OS Issues Fixed in Oracle Solaris 108 07 61 Software Documentation Updates 66 Miscellaneous Information 67 Identifying Degraded Memory inaSystem 67 Identifying Different Memory Sizes in a System Board 67 vi SPARC Enterpris
99. re it switches and SHUTDOWN timeout may be stored in the error log RTIF1 O While XSCF is running error message Check that XSCF is started If not 071116 006 of hang up is detected might be started use the rebootxscf 8 displayed to XSCF console and XSCF command to restart XSCF or stop all may reboot the domains and then execute the system power off on AC OFF ON To turn on the system power that you turned off wait at least 30 seconds before power on RTIF1 O O If the following message is displayed on Replace the XSCF Unit 071129 001 XSCF console the XSCF might not start dbs xxx ERR scdb_init_all xx No space left on device In addition this error log might be registered XSCF process down detected RTIF1 O O When performing XSCF Shell None available at this time 071129 002 commands remotely using SSH on the remote control device the following messages might be displayed stty standard input Invalid argument RTIF1 O O An error log cannot be registeredin No workaround is available 071129 003 XSCF when the following message is displayed on Oracle Solaris OS by the I O error SUNW MSG ID TYPE Fault SUN4 8000 4P Chapter 3 Information About Software 29 TABLE 3 3 XCP Issues Fixed in Releases Earlier Than XCP 1110 Continued M4000 M8000 ID M3000 M5000 M9000 Description Workaround RTIF1 O O The following messages are displayed Confirm the OpenBoot PROM 071129 004 and you might not boo
100. res rebuild of hardware RAID and the data restore from the backup media might become necessary m To ensure data integrity in time of power failure it is recommended to use an uninterruptible power supply UPS a If you require higher availability such as the controller or the data path redundancy use the dedicated RAID system 71 Notes on Building or Deleting the Hardware RAID m The data in the disk drive is not secured during the build or the deletion of a hardware RAID When you newly build a hardware RAID while the system is running or delete the built hardware RAID once do not fail to make backup copies of the data After building a hardware RAID you need to install data newly or restore data from the backup media m The hardware RAID build or the synchronization associated with maintenance takes about 180 minutes for a 300 GB HDD with unloaded condition For 600 GB HDD it takes about 360 minutes m If there is a system restart during the hardware RAID build or synchronization the build synchronization must be started again from the beginning m When the hardware RAID applied the volume size is smaller than the size of original disk Notes on Operating the Hardware RAID In some cases RAID controller cannot conclude the disk drive is completely in failure and system slowdown might occur To do maintenance in this status follow the procedures below 1 Delete the hardware RAID 2 Replace all the member disks rela
101. rger install Oracle Solaris OS than 2TB might fail 6966086 O bge interface can not enable Jumbo This has been fixed in patch 144563 02 Frame function This issue is caused on the M3000 Workaround server with SPARC64 VII processors No workaround is available 7009474 O O O After applying 144563 01 or 144563 02 Check the link status by using the patch bge interface does not display link_state parameter from the link up down message on console and kstat 1M output syslog when plugging unplugging Oracle Solaris OS Issues Fixed in Oracle Solaris 10 9 10 TABLE 3 5 lists issues that have been fixed in Oracle Solaris 10 9 10 OS You might encounter them in supported releases earlier than Oracle Solaris 10 9 10 TABLE 3 5 Oracle Solaris OS Issues Fixed in Oracle Solaris 10 9 10 M4000 M8000 CR ID M3000 M4000 M9000 Description Workaround 6668237 O O O After DIMMs are replaced the This has been fixed in patch 143527 01 corresponding DIMM faults are not cleared on the domain Workaround Use the following commands fmadm repair fmri uuid fmadm rotate 48 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 TABLE 3 5 Oracle Solaris OS Issues Fixed in Oracle Solaris 10 9 10 Continued M4000 M8000 CR ID M3000 M4000 M9000 Description Workaround 6872501 O O O If 139555 08 has been applied to the This has been fixed in patch 143359 02 domain cores are not offlined when request
102. rmware Version 1 31 00 00 arget 4 Unit 0 Removable Read Only device TEAC DV W28S V J 0B SATA device PhyNum 4 2 Select the device and confirm that the RAID volume is reported but inactive 0 ok select pci 0 600000 pci 0 pci 0 scsi 0 0 ok show volumes Volume 0 Target 82 Type IM Integrated Mirroring Optimal Enabled Inactive 2 Members 585805824 Blocks 299 GB Disk 1 Primary Online Target 0 FUJITSU MBD2300RC 3702 Disk 0 Secondary Online Target 1 FUJITSU MBD2300RC 3702 3 Use the activate volume command to activate the RAID volume 0 ok 0 activate volume Volume 0 is now activated 0 ok show volumes Volume 0 Target 0 Type IM Integrated Mirroring Degraded Enabled Resync In Progress 2 Members 585805824 Blocks 299 GB Disk 1 Primary Online Target 8 FUJITSU MBD2300RC 3702 Disk 0 Secondary Online Out Of Sync Target 1 FUJITSU MBD2300RC 3702 Chapter 4 Information About Hardware of M3000 Server Note If there are multiple RAID volumes they must be activated in descending order as shown below 0 ok 1 activate volume Volume 1 is now activated 0 ok 0 activate volume Volume 0 is now activated 4 Confirm that it is now possible to boot off the RAID volume Activating the RAID volume causes it to re sync 0 ok unselect dev 0 ok setenv auto boot false auto boot false 0 ok reset all Resetting 0 ok probe scsi all pci 0 600000 pci 0
103. rror can lead to an invalid fault For Oracle Solaris 10 8 07 or earlier diagnosis on a large M8000 M9000 this has been fixed in patch 127127 11 domain Workaround Create a file etc fm fmd fmd conf containing the following lines setprop client buflim 40m setprop client memlim 40m 6402328 O System panic might happen due to be For Oracle Solaris 10 8 07 or earlier over the interrupt number limit when this has been fixed in patch 127127 11 one domain has seven or more IOUA cards Workaround Use six or less IOUA cards on one domain 6472153 O O If you create an Oracle Solaris OS Flash For Oracle Solaris 10 8 07 or earlier archive on a non M4000 M5000 M8000 M9000 sun4u server and install it on a M4000 M5000 M8000 M9000 sun4u server the console s TTY flags will not be set correctly This can cause the console to lose characters during stress this has been fixed in patch 137046 01 Workaround Just after installing Oracle Solaris OS from an Oracle Solaris Flash archive telnet into the M4000 M5000 M8000 M9000 server to reset the console s TTY flags a follows sttydefs r console sttydefs a console i 9600 hupcl opost onlcr crtscts f 9600 This procedure is required only once 56 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 TABLE 3 9 Oracle Solaris OS Issues Fixed in Oracle Solaris 10 5 08 Continued M4000 M8000 CR ID M3000 M5000 M9000 Description Workaroun
104. rtfru 8 command SPARC Enterprise setupfru 8 M3000 M4000 M5000 command M8000 M9000 Servers XSCF Reference Manual and XSCF man pages Service Processor HTTPS Service will be changed as follows With disable the HTTPS service stops immediately With enable the HTTPS service starts after the XSCF is reset by execution of the reboot xsc 8 command XSCF does not support a redirection of an output The following description will be removed Output can be redirected to a file The following description also applies to M4000 M5000 servers Although a CMU with two CPUs can be configured into Quad XSB mode on an M8000 M9000 server the server generates a configuration error message for those XSBs that do not have a CPU and memory 66 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 Miscellaneous Information Identifying Degraded Memory in a System 1 Log in to XSCF 2 Type the following command XSCF gt showstatus The following example identifies that DIMM number 00A on CMU 3 has degraded memory XSCF gt showstatus CMU 3 Status Normal MEM 00A Status Degraded Identifying Different Memory Sizes in a System Board To identify if the domain contains system boards with different memory sizes you can use either of the following commands to display the list of memory sizes m showdevices 8 command on the XSCF m prtdiag 1M command on the domai
105. s Notes on RCI Function The RCI function is supported on any of the following servers m The server which you purchased in Japan from Fujitsu m The server which is bearing the Fujitsu logo on the front surface regardless of area of purchase When using the RCI function such as RCI build procedure see the SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers RCI Build Procedure and the SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers RCI User s Guide 1 This refers to the server which has the black colored chassis and is exclusively bearing the Fujitsu logo on the front surface 13 Notes on Remote Maintenance This section is explained the notes on using the remote maintenance service For details on making settings and using the remote maintenance service see the manuals about the remote maintenance service in the Enhanced Support Facility User s Guide for REMCS Before Setting the Remote Maintenance Service Before using the remote maintenance service on your M3000 M4000 M50900 M8000 M9000 server you have to complete the settings for the REMCS Agent function on XSCF Web Be sure to complete the necessary settings for using XSCF Web such as enabling the HTTPS on XSCF shell After completing specify the settings for REMCS Agent function on XSCF Web For detail on the settings for XSCF Web see SPARC Enterprise M3000 M4000 M5000 M8000 M9000 Servers XSCF User s Guide Enabling and Disabling the REMCS Agent
106. s Product Notes for XCP Version 1110 January 2012 XCP Issues Fixed in Releases Earlier Than XCP 1110 TABLE 3 3 lists XCP issues that have been fixed in releases earlier than XCP 1110 TABLE 3 3 XCP Issues Fixed in Releases Earlier Than XCP 1110 M4000 M8000 ID M3000 M5000 M9000 Description Workaround RTIF1 O O All domains must be powered off Power off domains before using the 070418 004 before upgrading the XCP flashupdate 8 command to upgrade XCP firmware RTIF1 O O If you log in to the XSCF while it is still Log out of the bash prompt and wait 070418 005 booting you may get a bash prompt for the XSCF to finish booting instead of the XSCF gt prompt and be unable to perform most operations RTIF1 O O While XSCF is running a process may M8000 M9000 servers 070418 009 go down a watchdog timeout may Check that XSCF is started If there is occur or a hang up may occur After this XSCF may reset XSCF unit which is not started execute the replacefru 8 command and then uninstall the XSCF unit and install it again Or stop all the domains and then execute the system power off on AC OFF ON To turn on the system power that you turned off wait at least 30 seconds before power on M4000 M5000 servers Check that XSCF is started If not started stop all the domains and then execute the system power off on AC OFF ON To turn on the system power that you turned off wait at least 30 seconds before power on
107. se such defects occurred stop the use of USB memory immediately To connect the USB memory to the USB port for XSCF connect the USB memory directly to the USB port If connected via USB hub or USB extension cables it may cause errors Power Control and Operator Panel Mode Switch Note Before using the RCI function see Notes on RCI Function on page 13 When you use the remote power control utilizing the RCI function or the automatic power control system APCS you can disable this remote power control or the APCS by setting the mode switch to Service mode on the operator panel Disabling these features ensures that you do not unintentionally switch the system power on or off during maintenance Note that system power off with the APCS cannot be disabled with the mode switch Therefore be sure to turn off automatic power control via APCS before starting maintenance Chapter 4 Information About Hardware of M3000 Server 73 If you switch the mode while using the RCI or the automatic power control the system power is controlled as follows TABLE 4 1 RCI and APCS Control with Mode Switch Function Mode Switch Locked Service RCI Remote power on power off op Remote power on power off op erations are enabled erations are disabled APCS Automatic power on power off Automatic power on is disabled operations are enabled but power off remains enabled To use the RCI function see the SPARC Enterprise M3000
108. t Oracle Solaris environment variable If the variable OS has errors set the variable again e Abnormal OpenBoot environment variable Boot process failed e ERROR Invalid token FATAL NVRAM contents corrupt Reinitializing NVRAM parameters RTIF1 O O In XSCF write of date and time may Execute the rebootxscf 8 command 071227 001 become an error When the domain to restart XSCF powered on the following message may appear and the domain may fail to be powered on Poweron canceled due to invalid system date and time RTIF1 O O When the showhardconf 8 command Press Ctrl C to terminate the 071227 002 executed in an environment with the showhardconf 8 command and External I O Expansion Unit the execute the showhardconf 8 showhardconf 8 command may command again appear as if hang up RTIF1 O O When a non existent device name Specify the correct device name to the 071227 003 specified to the Boot device path and Boot device path resulted in the OS Boot error the status of I O unit may become Degraded When the status of I O unit became Degraded replace the I O unit 30 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 TABLE 3 3 XCP Issues Fixed in Releases Earlier Than XCP 1110 Continued M4000 M8000 ID M3000 M5000 M9000 Description Workaround RTIF1 O O When you set XSCF as the NTP server Perform either one of the following 080313 001 of the domain following message may wor
109. t XSCF RTIF1 O O O In XSCF a host route cannot be set To set a host route do not specify the 091109 002 When you use the setroute 8 netmask m option command and set the netmask to 255 255 255 255 it returns an invalid parameter RTIF1 O O O When you use the setnameserver 8 To delete all the DNS servers or the 091109 003 command or the DNS setting of XSCF search paths which are same specify Web to register the DNS server or the search path you can specify two or more same IP address values or domain names However when you specify two or more same IP address values or domain names to delete all the DNS servers or the search paths which are same it returns an invalid parameter just one corresponding address or domain name In doing so all the DNS servers or the search paths which are same will be deleted Register the data again as needed Chapter 3 Information About Software 39 TABLE 3 3 XCP Issues Fixed in Releases Earlier Than XCP 1110 Continued M4000 M8000 ID M3000 M5000 M9000 Description Workaround RTIF1 091109 004 O O O When you start up a domain from a disk connected to the 8 Gbps fibre channel card SE0X7F21F SE0X7F22F if you fail to specify the correct device path an error log with no message might be registered In the same way when you start up a domain from a disk connected to the 8 Gbps fibre channel card SE0X7F21F SE0X7F22F even if the domain cannot be start
110. ta 3 The panic message will contain the following string bad kernel MMU trap at TL 2 For Oracle Solaris 10 8 07 or earlier this has been fixed in patch 125369 05 Workaround To avoid this problem issue the following commands on the domain cd usr platform SUNW SPARC Enterprise lib fm topo plugins mv ioboard so ioboard so orig svcadm restart fmd If the following messages are displayed on the domain contact a service engineer Example SUNW MSG ID SUNOS 8000 1L TYPE Defect VER 1 SEVERITY Minor EVENT TIME Sun May 6 18 22 24 PDT 2007 PLATFORM SUNW SPARC Enterprise CSN BE80601007 HOSTNAME sparc Ez For Oracle Solaris 10 8 07 or earlier this has been fixed in patch 127111 08 No workaround is available 58 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 TABLE 3 9 Oracle Solaris OS Issues Fixed in Oracle Solaris 10 5 08 Continued M4000 M8000 CR ID M3000 M5000 M9000 Description Workaround 6545685 O O If the following message displayed on For Oracle Solaris 10 8 07 or earlier the OS console memory degradation or this has been fixed in patch 127111 08 XSB deconfiguration may occur in the subsequent reboot Workaround Add the following to etc system Example and then reboot the domain mc opl WARNING mc opl set mc opl rewrite timeout on LSBO BO mc max rewrite loop 20000 6546188 O O The system panics w
111. ted to the hardware RAID 3 Rebuild the hardware RAID 4 Restore the data from the backup media Notes on raidct1 1M Command The following options of the raidct1 1M command can not be used because the hardware specifications do not support them m rvaidctl C r 1E To create a RAID 1E m raidctl c r 1E To create a RAID 1E m raidctl a To assign hot spare disks m raidctl p To set the cache m raidctl C z To specify the volume capacity 72 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 Notes on DVD Drive and Discs See the Notes on DVD Drives and Discs in SPARC Enterprise on the website below before using the CD DVD discs in the standard DVD drive mounted in this server http www fujitsu com sparcenterprise manual Notes on the Use of USB Memory To execute the dumpconfig 8 restoreconfig 8 or snapshot 8 command if you specify USB memory as the destination to store data prepare the USB memory as a medium in advance The data stored will include the information about the system To use USB memory you need to pay attention to the management of the USB memory in which the data stored from the data security viewpoint We do not provide guarantees to every USB memory from any manufacturers that currently on the market against its connectivity to XSCF and proper operation Depending on the USB memory in use defects such as the XSCF firmware error or reset may occur In ca
112. tenance menu of the addfru 8 board being unavailable for DR after or replacefru 8 command In case of the addfru 8 or replacefru 8 missing the diagnostic test in the command have been used for active maintenance menu of the addfru 8 or replacement This happens when the the replacefru 8 command execute active replacement is done without the the testsb 8 command or delete the diagnostic test in the maintenance CPU memory board unit using the menu deletefru 8 command and then retry the addfru 8 command RTIF1 O When the server is being installed and Turn off the system AC power then 071126 002 the mainline switch is turned on for the turn it on again first time these error messages might When the error log is displayed again be displayed turn off the system AC power then turn PSU shortage it on again To turn on the system XSCF watchdog timeout power that you turned off wait at least XSCFU hang up is detected 30 seconds before power on XSCF process down detected RTIF1 O In setsnmp addv3traphost when the No workaround is available 080725 001 authentication failed due to the reasons Confirm that the SNMP trap host is such as the trap host not working or working and re execute the set snmp 8 the wrong user name or password the command using the correct user name subsequent SNMP traps will not be notified RTIF1 O When the SNMPv3 trap has been set Reset the XSCF 080725 002 after the watchdog timeout occurred in XSC
113. terprise CSN 2020642002 HOSTNAME lt hostname gt SOURCE fmd self diagnosis REV 1 0 EVENT ID 6b2e15d7 aa65 6bcc bcb1 cb03a7dd77e3 DESC A Solaris Fault Manager component has experienced an error that required the module to be disabled Refer to http sun com msg FMD 8000 2K for more information AUTO RESPONSE The module has been disabled Events destined for the module will be saved for manual diagnosis fmadm restart cpumem diagnosis IMPACT Automated diagnosis and response for subsequent events associated with this module will not occur REC ACTION Use fmdump v u lt EVENT ID gt to locate the module Use fmadm reset lt module gt to reset the module Boot program ignores the Kadb option Use kmdb instead of kadb which causes the system not to boot Chapter 3 Information About Software 47 TABLE 3 4 Oracle Solaris OS Issues and Workarounds for All Supported Releases Continued M4000 M8000 CR ID M3000 M4000 M9000 Description Workaround 6765239 O If a SAS device containing multiple SAS Use a FUJITSU SAS card targets is connected to the onboard SE0X7SA1F SE0X7SA1X external SAS interface it will not work Alternatively check for the availability properly The enumeration of target IDs of a patch for this defect within the device may change across reboots 6794630 O An attempt to use the GUI to install Use the Command Line interface to Oracle Solaris OS in a domain la
114. the Monitor Message Frame the invalid pop up Confirmation Domain mode may appear M8000 M9000 servers After XSCF Unit is replaced configures the RCI again and sets the remote power control mode M3000 M4000 M5000 servers After the motherboard unit is replaced configures the RCI again and sets the remote power control mode Select Domain Mode Configuration one more time and perform the settings Or once terminate the XSCF Web and then perform the settings None available at this time None available at this time Ignore the pop up and close the screen 22 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 TABLE 3 3 XCP Issues Fixed in Releases Earlier Than XCP 1110 Continued M4000 M8000 ID M3000 M5000 M9000 Description Workaround RTIF1 O O On the tab browser to the same host When you use the tab browser do not 070824 006 when you perform multiple log in with perform multiple log in to the same the user accounts of different user host privileges the user privilege of the last log in user account will be applied to those pages which you ve already logged in RTIF1 O O When you change configuration on the From the Menu select the original 070824 007 XSCF Web if you select cancel on the configuration page again confirmation dialog or perform forced close the original configuration page may be unavailable RTIF1 O O On the Domain Configuration screen None avai
115. the hardware RAID TABLE 4 2 Supported Conditions for the Hardware RAID Item Description Required Oracle Solaris OS At this time no patches are required patches Required ESF Enhanced 3 2 or later Support Facility patches XSCF firmware XCP 1101 or later RAID level RAID 1 IM Integrated Mirror only Two member disks can be configured per RAID volume Disk drive The member disks in a single RAID volume shall be made up of disk drives of the same capacity and of the same rotational speed Solid State Drive SSD is not supported Number of RAID volumes Up to two RAID volumes on a server Hardware Documentation Updates This section contains late breaking hardware information that became known after the documentation set was published and corrections in the M3000 server hardware documentation Chapter 4 Information About Hardware of M3000 Server 75 TABLE 4 3 lists known documentation updates TABLE 4 3 Hardware Documentation Updates Title Page Number Update SPARC Enterprise M3000 2 4 B type plug in the Note in 2 2 1 2 Power Cord Specifications Server Installation Guide should be substituted with the plug with lock function 3 12 The step 1 Confirm that the server is powered on in 3 5 2 Checking the Dual Power Feed will be changed to Confirm that the system is powered on by checking the output of the showdomainstatus a command from the XSCF Shell 4 6 4 5 Verifying Operation by Ru
116. to command error No workaround is available 50 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 Oracle Solaris OS Issues Fixed in Oracle Solaris 10 5 09 TABLE 3 7 lists issues that have been fixed in Oracle Solaris 10 5 09 OS You might encounter them in supported releases earlier than Oracle Solaris 10 5 09 TABLE 3 7 Oracle Solaris OS Issues Fixed in Oracle Solaris 10 5 09 M4000 M8000 CR ID M3000 M5000 M9000 Description Workaround 6588555 O O M8000 M9000 servers This has been fixed in patch 139555 08 XSCF failover during DR operation to the permanent memory might cause Workaround domain panic M8000 M9000 servers Do not start an XSCF failover while a M4000 M5000 servers DR operation is running Wait for a DR XSCF reset during DR operation to the operation to finish before starting the permanent memory might cause failover If you start the failover first domain panic wait for the failover to finish before starting the DR operation M4000 M5000 servers Do not start an XSCF reset while a DR operation is running Wait for a DR operation to finish before starting the reset 6623226 O O O The Oracle Solaris OS command This has been fixed in patch 140336 01 lockstat 1M or the dtrace lockstat provider might cause a system panic Workaround Do not use the Oracle Solaris OS lockstat 1M command or the dtrace lockstat provider 6680733 O O O Sun Quad port Gigabit Ethernet This has be
117. ut Hardware of M8000 M9000 Servers 93 Example of Securing the Cabinet to the Floor Surface Using the Fixing FIGURE 6 1 Bracket M9000 Server 850 33 5 Fixing bracket i p k 4 a M 171 _ 67 gt ji L CD EEN re A H Caster 914 36 0 1260 49 6 Leveling feet 7 4 oa t a L ta F t 175 6 9 66 99 99 66 2 6 3 9 3 9 2 6 Unit mm inch Front Upper view Fixing bracket C230 4130 X514 Bolt F6 B12 121 Metal washer F6 WB12 121 TE Metal washer F6 WM12 121 Floor Bushing C230 4080 X003 A A cross section 94 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 FIGURE 6 2 Example of Securing the Cabinet Through a Hole in the Floor Leveling feet Cabinet Bolt F6 B12 121 Chapter 6 Information About Hardware of M8000 M9000 Servers 95 96 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012
118. witching occurred on the pressing Ctrl q the Ctr1 key and redundant XSCF Units the domain the q key console may hang up 6592302 O O Unsuccessful DR operation leaves Try deleteboard 8 again memory partially configured 6619344 O The Sun Crypto Accelerator SCA 6000 To avoid the defect do not hot plug this might not work if hot plug configured card in slot 1 into slot 1 6625734 O Systems with large number of Use processor sets to bind application processors in a single domain environment may have suboptimal performance with certain workloads processes or LWPs to groups of processors Refer to the psrset 1M man page for more information 46 SPARC Enterprise Mx000 Servers Product Notes for XCP Version 1110 January 2012 TABLE 3 4 Oracle Solaris OS Issues and Workarounds for All Supported Releases Continued CR ID M4000 M8000 M3000 M4000 M9000 Description Workaround 6660168 6745410 O O O O Ifa ubc piowbeue cpu error occurs If FMA service fails issue the following on a domain the Oracle Solaris Fault command on the domain to recover Management cpumem diagnosis svcadm clear fmd module might fail causing an interruption in FMA service Then restart cpumem diagnosis If this happens you will see the following output in the console log SUNW MSG ID FMD 8000 2K TYPE Defect VER 1 SEVERITY Minor EVENT TIME Fri Apr 4 21 41 57 PDT 2008 PLATFORM SUNW SPARC En

Download Pdf Manuals

image

Related Search

Related Contents

V7 Carry Case Professional  Philips DesignLine Ultra-Slim Smart LED TV 55PDL8908S  NuSMV 2.6 User Manual    平成27年7月(Vol.52)  Lettre du Maire  Descargar - People Contact  L`écho des officines : Une journée très ordinaire D`A. POTIKÈR  Trust Megapixel USB2 Webcam Live WB-5600R  Vacon NX Inverters User`s Manual FI4  