1. 45 XLS1000 Installation and Service Manual for complete system requirements NOTE NOT TO BE USED FOR INSTALLATION PURPOSES CLASS A WIRING STYLE 6 3 SAC MODULE A B TB2 SAC SAC BUS BUS 7 47 410 OO Oh AA LCD KEYPAD CLASS B WIRING 3 SAC MODULE A B TB2 SAC SAC BUS BUS 4 7 4 l A AA LCD KEYPAD 120 OHM TERMINATING RESISTOR 120 OHM TERMINATING RESISTOR N secun CONTROL BUS A 4 000 FT 2 110M MAXIMUM CIRCUIT LENGTH ALL WIRING IS POWER LIMITED AND SUPERVISED NOTE XLS KPDISP REQUIRES 24 VDC FOR POWER M21102 Fig 1 Typical 3 SAC wiring 3 74 3639 1 SECURITY CONTROL MODULE AND KEYPAD DISPLAY 24 VDC SUPPLY 24 VDC SUPPLY TO NEXT DEVICE FROM LAST DEVICE RS 485 LINE RS 485 LINE M21101 Fig 2 Typical XLS KPDISP wiring ORDERING INFORMATION Shipping Wt Catalog Number Description Ib kg 3 SAC Security Control 0 5 23 Module XLS KPDISP Keypad Display 1 0 45 Cycoloy is a registered trademark of Borg Warner Corporation Automation and Control Solutions Honeywell International Inc Honeywell Limited Honeywell Limit e 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 www honeywell com buildingsolutions Honeywell U S Registered Trademark 2006 Honeywell International Inc 74 3639 1 Jl Rev 08 06
2. Honeywell Security Control Module and Keypad Display 3 SAC XLS KPDISP i i m raan 09094200 o 9 PASSUORD sICLEAR J ee _ beaa Security Control Module Keypad Display APPLICATION The 3 SAC Security Control Module is a key component in the true integration of security into the XLS1000 multiplexed life safety system The 3 SAC is the demarcation point between fire and security functions For jurisdictions requiring independent wiring of fire and security devices the 3 SAC offers two independent circuits Where fire and security devices are permitted to be connected to the same circuit both circuits can support fire and security functions All security devices that connect to a 3 SAC are designed and tested to strict fire alarm standards For example to enhance reliability the 3 SAC can be wired in a Class A Style 6 configuration thus delivering an additional level of system survivability over traditional systems employing Class B wiring The 3 SAC can be used in combination with the MODCOM Modem Communicator 3 MODCOM The MODCOM s dialer DACT function is used to transmit alarms to one or more central monitoring stations and or paging terminals SPECIFICATION DATA FEATURES e Listed for fire and security Security Control Module e Two supervised RS 485 device circuits e 4 000 ft 1 220 m maximum circuit length e XLS1000 local rail module e Supports cont
3. cate PINs are permitted by the XLS KPDISP so a user can pick a number that is easy for him her to remember The XLS KPDISP can also annunciate fire functions and be programmed to act as a full function fire annunciator In the event of a problem context sensitive help is readily available using the HELP button SPECIFICATIONS Security Control Module Model 3 SAC Security Control Module Electrical Ratings Circuit Capacity 30 devices on one Class A circuit 62 devices on two circuits wired Class B Input Current 40 mA under all conditions Maximum Line Resistance 52 ohms Maximum Capacitance 0 1 uF Temperature Ratings 32 F to 120 F 0 C to 49 74 3639 1 2 Humidity Ratings 0 to 85 RH non condensing Wiring See Fig 1 Wire Size 22 AWG to 14 AWG 0 25 sq mm to 1 5 sq mm depending on specifications of connected devices Mounting One local rail space Compatibility Compatible with Honeywell Signature Loop Controller operating under Honeywell SDU version 3 1 or higher Approvals UL ULC see NOTE NOTE The XLS1000 is modularly listed under the following standards UL 864 categories UOJZ UOXX UUKL and SYZV UL 294 category ALVY UL 609 category AOTX UL 636 category ANET UL 1076 category APOU UL 365 category APAW UL 1610 category AMCX UL 1635 category AMCX ULC S527 ULC S301 ULC S302 ULC S303 ULC S304 ULC S306 ULC ORD C1076 ULC ORD C693 Refer to form no 95 7545 XLS1000 In
4. provided to prevent accidental keypad activation and protect against dirt The XLS KPDISP transmits and receives information from to the 3 SAC Security Access Control module installed in the XLS1000 system Communications between the XLS KPDISP and the 3 SAC are supervised providing the ultimate in reliability XLS KPDISP data is stored in non volatile memory Power to the XLS KPDISP is provided by the XLS1000 ensuring a reliable supervised and backed up power source The XLS KPDISP supports bilingual operation and can be programmed to automatically display the language of the user The display is backlit and lights whenever a key is pushed An automatic timer extinguishes the light after a brief delay The keypad features tactile and audible feedback and is backlit at all times To aid in locating the keypad in the dark the back lighting is visible even with the cover closed All operations are menu driven The most common use of the XLS KPDISP is arming and disarming security partitions The display permits a user to identify off normal points and take corrective action If the problems can not be corrected the user has the option to bypass a point before arming the system When used with the XLS1000 and the 3 MODCOM opening and closing signals may be sent automatically to a central monitoring station Up to 200 authorized users are assigned a pass code consisting of a unique three digit number and a four digit PIN number Dupli
5. rol display modules e Supervised by the network controller Keypad Display e 128 x 64 backlit dot matrix LCD display e Telephone style keypad with tactile and audible feedback e Removable protective cover e 200 users and 9999 pin codes e Supports bilingual operation e Menu driven e Non volatile memory Additionally information received by the MODCOM can be downloaded through the 3 SAC to individual security devices Refer to form no 74 3336 Modem Communicator Specification Data Sheet for additional details on the Honeywell MODCOM Total integration of the XLS1000 system assures that processing of fire alarm signals always receive the highest priority over routine signal processing Power for the 3 SAC comes from the same highly reliable power supply battery combination used to power the fire alarm components Any Control Display module will mount in front of the 3 SAC allowing greater flexibility of the system user interface layout The 3 SAC is used to connect the keypad displays to the XLS1000 network This permits the network to perform functions network wide in response to fire and or security events 74 3639 1 SECURITY CONTROL MODULE AND KEYPAD DISPLAY The XLS KPDISP Keypad Display is a combination keypad and dot matrix display designed for use with the XLS1000 integrated system The unit features a large LCD display and telephone style keypad housed in an attractive Cycoloy case A removable cover is
6. stallation and Service Manual for complete system requirements Keypad Display Model XLS KPDISP Keypad Display Electrical Ratings Circuit Configuration Class A or Class B Power Requirements 24 Vdc at 95 mA Temperature Ratings 32 F to 120 F 0 C to 49 C Humidity Ratings 0 to 93 RH non condensing Wiring See Fig 2 Wire Size 22 AWG to 14 AWG 0 25 sq mm to 1 5 sq mm Terminal Blocks One pair carries data in and out of the unit while the second pair provides power Communications RS 485 Supported Languages English Spanish French Hebrew Italian Dutch Polish Russian Turkish Portuguese Slovak Users 200 maximum per XLS KPDISP Partitions Supported 255 maximum per XLS KPDISP Mounting Directly on wall using 4 in 100 mm square or 2 gang electrical boxes Dimensions W x H x D 7 1 4 in 184 mm x 4 3 4 in 121 mm x 1 1 4 in 32 mm Open height 8 3 4 in 222 mm Finish White high impact Cycoloy thermoplastic SECURITY CONTROL MODULE AND KEYPAD DISPLAY Approvals UL ULC S527 see NOTE NOTE The XLS1000 is modularly listed under the following standards UL 864 categories UOJZ UOXX UUKL and SYZV UL 294 category ALVY UL 609 category AOTX UL 636 category ANET UL 1076 category APOU UL 365 category APAW UL 1610 category AMCxX UL 1635 category AMCX ULC S527 ULC S301 ULC S302 ULC S303 ULC S304 ULC S306 ULC ORD C1076 ULC ORD C693 Refer to form no 95 75
Download Pdf Manuals
Related Search
Related Contents
Piusi S.p.A. Suzzara - Italy INDICE 1. AVVERTENZE GENERALI 2 Português Para a Sua Segurança: Leia este guia do Manual de usuario 0367-0368-0369 fisher-price.com Dell E2014T - Guida dell`utente Philips Tornado High Lumen Spiral energy saving bulb 872790080832200 Clique aqui e faça o do manual de instruções do LightMoodsTM - AveoEngineering 取扱説明書 シヤー - 電動工具のホーマーズ Copyright © All rights reserved.