SoftPro EE - Water Softeners
Contents
1. 1 20 or OFF 2 Regenerant Draw Slow Rinse downflow 1 99 or OFF 3 Backwash 2 upflow 1 20 or OFF 4 Fast Rinse downflow 1 20 or OFF 5 Regenerant Refill with treated water 0 1 99 9 or OFF 6 Service downflow The user can initiate manual regeneration The user has the option to request the manual regeneration at the delayed regeneration time or to have the regeneration occur immediately 1 Pressing and releasing the REGEN button will flash towards Regen on the display and the regeneration will occur at the delayed regeneration time The user can cancel the request by pressing and releasing the REGEN button 2 Pressing and holding the REGEN button for approximately 3 seconds will immediately start the regeneration The user cannot cancel this request except by resetting the control by pressing NEXT and REGEN buttons simultaneously for 3 seconds Page 6 EE Manual User Displays General Operation Elow AM PM Days To Rat Time Regen Set Backwash Volume 1 1 Draw s SUL FF V REGEN Flow AM PM Days To Rate Time Regen E Set Backwash Volume Draw X 1000 Rinse Regen Fill next REGEN Flow AM PM Days To Rate Time Regen Set Backwash Volume Draw X 1000 Rinse Regen Fill Flow AM PM Days To Time Regen Set Backwash Volume lt Draw X 1000 Rinse Regen Fill NEXT REGEN P
2. rate user displays and the volume display in Diagnostics will be shown as 0 e If 28 is selected the regeneration will occur on the day 1 through 28 selected in Installer Display Settings The total flow and flow rate user displays and the volume display in Diagnostics will not be shown even if a meter is used e If 7 is selected the regeneration will occur on the selected day s of the week see instructions contained in Installer Display Settings The total flow and flow rate user displays and the volume display in Diagnostics will not be shown even if a meter is used Press NEXT to go to Step 4CS Press REGEN to return to previous step Step 4CS Press the A or Y buttons to select to regenerate immediately on 0 or at delayed time Immediately on 0 can only be selected if Volume gallons was selected in step 3CS and a meter must be installed Delay is the only option for the other Step 3CS selections Press NEXT to go to Step 5CS Press REGEN to return to previous step 1 When using the WS2 control valve the circuit board software must have meter selection choices of 2 0 and 2 0L The WS2 valve must be set for the 2 0 meter selection during programming If the software version does not have both the 2 0 and 2 0L selections consult your equipment supplier for a replacement circuit board When using the WS2L valve with older version software that does not have both 2 0 and 2 0L selection choices the valve must be set to 2 0 during programmi
3. type 2032 Battery Fully Seated EE Manual Page 5 Regeneration and Error Screens Regen Screen ime Displays the time remaining in the current cycle Tim Set Backwash Pressing REGEN advances to the next cycle Volume a Draw X 1000 Rinse Regen lt Fill next A _ REGEN Flow AM PM Days To Rate Regen Error Screen Alternated flashing Err and error code every 3 seconds Clear by dissconnecting the power supply at the PC board and reconneting or press the NEXT and REGEN buttons simutaneously for 3 seconds Button Operation and Function NEXT Scrolls to the next display Pressing once and releasing will schedule a regeneration at the preset delayed regeneration time Pressing again and releasing will cancel the regeneration REGEN Pressing and holding for 3 seconds will initiate an immediate regeneration Pressing while in regeneration will advance to the next cycle Pressing in the program levels will go backwards to the previous screen A V Changes variable being displayed 7 NEXT REGEN Al Key sequence to lock and unlock program settings Holding for 3 seconds initiates a control reset The software version is displayed and the piston returns to NEXT REGEN We the home service position resynchronizing the valve Regeneration Cycles and Times Range of times min 1 Backwash 1 upflow
4. EN to go to previous display Step 5I Use the A or Y buttons to set the regen minutes Press NEXT to exit Installer Display Press REGEN to return to previous display EE Manual Page 13 Diagnostics Step 1D Step 1D Press A and Y buttons simultaneously for 5 seconds and release Then press A and Y buttons NEXT AIV REGEN simultaneously for 2 seconds and release If screen in Step 2D does not appear the lock on the valve is activated To unlock press NEXT REGEN A in sequence then press A and W buttons simultaneously NEXT Fad EA REGEN for 5 seconds and release Then press A and Y buttons simultaneously for 2 seconds and release a in Ed Step 2D Display shows the number of days since a Rate Time Regen regeneration last occurred Press NEXT to go to Step Set a EN 3D Press REGEN to exit Diagnostics Volume E Draw X 1000 Rinse Regen Fill ey av Step 3D Step 3D Display shows the volume of water treated Flow AM PM Days To in gallons treated since the last regeneration If Volume Rate Time Regen gallons 28 Volume gallons or 7 Volume gallons Set Backwash was selected in Step 3CS and no meter is installed this x t000 E E Rinse display will read 0 Press NEXT to go to Step 4D Press Regen lt a Fil REGEN to return to previous step V REGEN Step 4D Step 4D Display shows the days in service since start Flow AM PM Days To up Press NEXT to go to Step 5D Press REGEN to Rat T
5. Installer Display Step 31 Adjust day override from 1 28 or OFF Press NEXT to go to Step 4I Press REGEN to return to previous step Step 4I Use A or Y buttons to set the regen hour Press NEXT to go to Step 51 Press REGEN to return to the previous step Step 5I Use A or Y buttons to set the regen minutes Press NEXT to exit Installer Display Press REGEN to return to previous step 28 Day or 28 Volume Gallons selected in Configuration Settings Step 3CS next A recen Ye Step 21 Flow AM PM Days To Rate Time Regen Set Backwash Draw X 1000 Rinse Fill next A REGEN y Flow AM Rate PM Days To Time Regen Set eur Backwash Volume j Draw X 1000 al Rinse Regen lt a Fill van Next V recen y Flow AM PM Days To Rate Time Regen IN Set lt Backwash EXITTO oo g Rinse DISPLAY Reden a iu Fil SCREENS NEXT A V recen Step 1I To enter Installer Display press the NEXT and A buttons simultaneously for five seconds and release Step 2I Adjust days from 1 28 Press NEXT to go to Step 3I Press REGEN to exit Installer Display Step 3I Use A or Y buttons to set time of the regen hour Press NEXT to go to Step 41 Press REGEN to return to previous step Step 4I Use A and Y buttons to set the regen minutes Press NEXT to exit Inst
6. M Days To Time Regen Set Backwash Volume Draw X 1000 5 Rinse Regen Fill PM Days To Time Regen oF Set lt Backwash Volume Draw X 1000 Rinse Regen Fill LENN CTA TY m Flow AM PM Days To Rate Time Regen Set Backwash Volume Draw X 1000 Rinse Regen Fill FETT NANN TA V Je When the system is operating one of five displays may be shown Pressing NEXT will alternate between the displays shown below User 1 Typical user display If volume is selected in Configuration Settings Step 3CS shows volume remaining to regeneration If volume is not selected in Configuration Settings Step 3CS this screen will not be shown If a meter is not used this display will not change User 2 Displays number of days to next regeneration User 3 Displays flow rate in gallons per minute If a meter is not used this display will be shown but O will be displayed This screen will not be shown if 7 day or 28 day is selected in Configuration Settings Step 3CS User 4 Displays total flow in gallons since last reset If a meter is not used this display will be shown but 0 will be displayed This screen will not be shown if 7 day or 28 day is selected in Configuration Settings Step 3CS PRESS THE DOWN V ARROW FOR 3 SECONDS TO RESET TO 0 User 5 Shows current time Setting Time of Day Push NEXT button until time of day screen is displayed Press and hold the A or Y arrow until th
7. Water Specialist EE Control Valve Programming and Cover Drawing Manual Page 2 EE Manual EE Manual Page 3 Table of Contents BE Front Cover and Drive Assembly seat dea 4 Regeneration and Error Screens Button Operations and Functions unseessersnesnerseesnennnesnnennennnennesnennnennnnnnennnnnennnennen 5 MISC TIS DIAS u un is a ia 6 Configuration SEUS A o its a setting Regeneration Cycle Mes ua nennen ra 10 Installer Dis play Settings vs 11 Dianos cv Eee aa aa E A E vasqaes yates subs E deepubstocguetseev secs 13 Page 4 EE Front Cover and Drive Assembly EE Manual Drawing No Order No Description Quantity 1 V3175EE 01 WSIEE FRONT COVER ASSEMBLY 1 V3107 01 WS1 MOTOR V3106 01 WS1 DRIVE BRACKET amp SPRING CLIP V3408EE 02BOARD WSITHRU2L EEPCBRD MAV ALT REPL V3110 WS1 DRIVE GEAR 12X36 Nin Ri wld V3109 WS1 DRIVE GEAR COVER me W V3186 WS1 AC ADAPTER 110V 12V Not Shown V3186 01 WS1 AC ADAPTER CORD ONLY Not Shown V3178 WS1 Drive Back Plate Refer to Control Valve Service Manual for other drawings and part numbers AC Adapter US International Supply Voltage 120 VAC 230V AC Supply Frequency 60 Hz 50 Hz Output Voltage 12 VAC 12 VAC Output Current 500 mA 500 mA When replacing the battery align positives and push down to fully seat an a N Battery replacement is 3 volt lithium coin cell
8. Y buttons simultaneously for 5 seconds and release If screen in Step 2CS does not appear the lock on the valve is activated To unlock press V NEXT REGEN A in sequence then press A and Y buttons simultaneously for 5 seconds and release Step 2CS Choose 1 0 for 1 1 25 for 1 25 1 5 for 1 5 2 0L for 2L 2 0 for 2 valve Press NEXT to go to Step 3CS Press REGEN to exit Configuration Settings Note When using the WS2 valve if 2L is set instead on 2 0 for valve type when the valve is in regeneration and the piston drives to the Draw cycle the piston will stall and generate a 1002 error code Clear error code by pressing NEXT and REGEN simultaneously until the valve resets then re program to proper valve type setting Step 3CS Press the A or Y buttons to select one of the following e If Volume gallons is selected the regeneration will occur after the specific volume has been used or on the day override if selected whichever comes first e If 28 Volume gallons is selected the regeneration will occur on the day 1 through 28 selected in Installer Display Settings If a meter is not used the total flow and flow rate user displays and the volume display in Diagnostics will be shown as 0 e If 7 Volume gallons is selected the regeneration will occur on the selected day s of the week see instructions contained in Installer Display Settings If a meter is not used the total flow and flow
9. aller Display Press REGEN to return to previous step Page 12 EE Manual 7 Day or 7 Volume Gallons selected in Configuration Settings Step 3CS REGEN Step 2I PM Days To Regen Flow AM Rate Time Set Backwash Volume Draw X 1000 Rinse Regen Fill fee ATV Tes Step 31 PM Days To Regen Flow AM Rate Time Backwash d Draw u Rinse a N Fill Bay BETTEN PM Days To Regen Set lt Volume X 1000 Regen Flow AM Rate Time Backwash Draw Rinse Fill CNS Step 51 Step 51 PM Days To Regen Flow AM Rate Time ANS Backwash Volume y D a X 1000 a E Regen Fill LANNIAINA Jai v Set EXIT TO DISPLAY SCREENS Step 1I To enter Installer Display press the NEXT and A buttons simultaneously for 5 seconds and release Step 21 Use A or Y buttons to set the current day of the week Default 2 Monday 1 SUNDAY 2 MONDAY 3 TUESDAY 4 WEDNESDAY 5 THURSDAY 6 FRIDAY 7 SATURDAY Press NEXT to go to Step 31 Press REGEN to exit Installer Display Step 31 Scroll through days 1 to 7 using the NEXT button Use the A or Y buttons to turn regen on or off for each individual day regen indicator on means regeneration will happen After completing the 7th day press NEXT to go to Step 41 Press REGEN to go to previous display Step 4I Use the A or Y buttons to set the regen hour Press NEXT to go to Step 51 Press REG
10. e SET indicator is displayed and the hour flashes Press the A or Y button until the correct hour is displayed Then press the NEXT button The minutes will flash Press the A or Y arrow until the correct minute is displayed Press the NEXT button to return to the Display Screens Time of day should only need to be set after power outages lasting more than 8 hours if the battery has been depleted and a power outage occurs or when daylight saving time begins or ends If a power outage lasting more than 8 hours occurs the time of day will flash on and off which indicates the time of day should be reset If a power outage lasts less than 8 hours and the time of day flashes on and off the time of day should be reset and the battery replaced EE Manual next ReGen Step 2CS Flow AM PM Days To Rate Time Regen Set 4 Na Backwash Volume Draw X 1000 Rinse Regen ETE Fill next _ REGEN Flow AM Rate Set Volume 3 x 1000 775 Regen lt q 1 Step 3CS PM Days To Time Regen Backwash Draw Rinse Fill lt A REGEN NEXT Flow AM Rate Step 4CS PM Days To Time Regen Set Y Volume X 1000 Regen lt q wat IIA Backwash Draw Rinse Fill NEXT A V REGEN y Page 7 Configuration Settings Step 1CS Press A and
11. ernator systems using the WS2 valve when NEXT is pressed after selecting ALTA or ALTb a display will allow the user to set the amount of pre service rinse time for the stand by tank just prior to returning to service Press NEXT to go to Step 6CS Press REGEN to return to previous step EE Manual Flow AM Rate Step 6CS PM Days To Regen Time Set Volume X 1000 a Regen wes TIAN wis TINY Backwash Draw Rinse Page 9 Step 6CS Set duration of the special rinse cycle to be performed prior to a valve returning to Service Selectable from 1 20 minutes or OFF Only viewed if 2 0 is set in 2CS and ALTA or ALTb is set in 5CS Fill NEXT A V REGEN y Step 7CS Flow AM PM Days To Rate ime Regen Set l Backwash Volume Draw X 1000 Rinse Regen Fill GTA V REGEN EXIT TO DISPLAY SCREENS Press NEXT to go to Step 7CS Press REGEN to return to previous step Step 7CS Flow AM PMDaysTo Selecting the use of an outside signal to initiate a regeneration Selection only matters if a connection is made to the two pin Ls C Backwash Connector labeled DP SWITCH located on the printed circuit eon jt r board Following is an explanation of the options oFF Feature not used A y REGEN on0 If the dP switch is closed for an accumulative time of 2 minutes a regene
12. ime Regen return to previous step Set Backwash Volume p D Draw X 1000 Rinse Regen Fill er A V ren Step 5D Step 5D Display shows the total number of Flow AM PM Days To regeneration cycles since start up Press NEXT to exit Rat Time Regen Diagnostics Press REGEN to return to previous step Set Backwash Volume Draw X 1000 Ll N Rinse Regen Fill EXIT TO DISPLAY REGEN SCREENS Page 14 EE Manual EE Manual Page 15 Page 16 EE Manual Revision History 10 13 2008 PAGES 11 13 Updated Motorized Alternating Valve and No Hard Water Bypass instructions 1 5 2009 ro gt ep E YN NO Updated the instructions for Step 7CT 3 16 2009 PAGES 10 amp 11 Revised Step 2CS Revised Step 5CS 3 30 2009 Page order changed after page 6 PAGE 7 Added note to Step 2CS 4 1 2009 PAGES Corrected display header in Step 5CS PAGE 9 Corrected display header in Step 6CS Form No V3435EE 4 1 2009
13. lack No Hard Water Bypass Valve is made to the two pin connector labeled ALTERNATOR DRIVE located on the printed circuit board If using a MAV the A port of the MAV must be plugged and the valve outlet connected to the B port When set to nHbP the MAV will be driven closed before the first regeneration cycle that is not FILL or SOFTENING or FILTERING and be driven open after the last regeneration cycle that is not FILL NOTE If the control valve enters into an error state during regeneration mode the no hard water bypass valve will remain in its current state until the error is corrected and reset nfiguring th ntrol Valve for r r ration Select nHbP for control operation For separate source operation the three wire connector is not used Selection requires that a connection to a Clack Motorized Alternator Valve MAV is made to the two pin connector labeled ALTERNATOR DRIVE located on the printed circuit board The C port of the MAV must be connected to the valve inlet and the A port connected to the separate source used during regeneration The B port must be connected to the feed water supply When set to nHbP the MAV will be driven closed before the first regeneration cycle and be driven open after the last regeneration cycle NOTE If the control valve enters into an error state during regeneration mode the MAV will remain in its current state until the error is corrected and reset lecting th ntrol Valve t t n alternator Prior to sta
14. me Draw X 1000 Rinse Regen B Fill DABAN EXIT TO piseLay NEXT Y REGEN SCREENS Step 1CT Press NEXT and Y simultaneously for 5 seconds and release If screen in Step 2CT does not appear the lock on the valve is activated To unlock press V NEXT REGEN A in sequence then press NEXT and Y simultaneously for 5 seconds and release Step 2CT Select between SOFTENING or FILTERING When set to FLTr 7CT is not set to off and 2CS is set to 1 0 a fixed 30 second Backwash is automatically added to the regen cycle program after Rinse 6CT The status display for this extra backwash will appear as just another cycle step in sequence Press NEXT to go to Step 3CT Press REGEN to exit Regeneration Cycle Times Step 3CT Adjust the length of the backwash from 1 20 minutes or OFF using the A or Y buttons Press NEXT to go to Step 4CT Press REGEN to return to previous step Step 4CT Adjust the length of the regenerant draw from 1 99 minutes or OFF using the A or Y buttons Press NEXT to go to Step SCT Press REGEN to return to previous step Step 5CT Adjust the length of the second backwash from 1 20 minutes or OFF using the A or Y buttons Press NEXT to go to Step 6CT Press REGEN to return to previous step Step 6CT Adjust the length of rinse from 1 20 minutes or OFF using the A or Y buttons Press NEXT to go to Step 7CT Press REGEN to return to previous step Step 7CT Adjust
15. ng If a WS2L valve is being used with newer version software that has both 2 0 and 2 0L selection choices the valve must be set to 2 0L during programming Page 8 EE Manual Step 5CS Step 5CS Allows selection of one of the following El AM PM Days To El AM PM Days To using the A or v buttons Ow ow Rate Time Regen Rate Time Regen e the Control Valve to have no hard water bypass Set lt a Backwash 4 se lt q gt Backwash the Control Valve to act as an alternator or Volume E o Volume Draw X 1000 n 1 Rinse X 1000 0 r Rinse e the Control Valve to have a separate source during the Regen i Fi er TER El regeneration cycle next A AY REGEN next A V REGEN Select OFF when none of these features are used Only use Clack No Hard Water Bypass Valves or Clack Motorized Alternating Valves MAV with these selections Clack No Hard Water Bypass Valves 1 or 1 25 V3070FF or V3070FM are not designed to be used with the alternator or separate source functions The V3063 and V3063BSPT motorized alternating valves are not designed to be used as a no hard water bypass or separate source inlet if the pressure differential is more than 60 psi nfiguring th ntrol Valve for No Har ter B ration Select nHbP for control operation For no hard water bypass operation the three wire connector is not used Selection requires that a connection to MAV or a C
16. ration will occur immediately dELy If the dP switch is closed for an accumulative time of 2 minutes a regeneration will occur at the scheduled regeneration time HoLd If the dP switch is closed a regeneration will be prevented from occurring Not viewed if Step 5CS is set to ALTA or ALTb Press NEXT to exit Configuration Settings Press REGEN to return to previous step Page 10 EE Manual Setting Regeneration Cycle Times NEXT A REGEN Step 2CT Flow AM PM Days To Rate Time_ Regen Set ag ab ares Backwash Volume Brine X1000 Rinse Regen Fill ATAN next Y REGEN Step 3CT Flow AM PM Days To Rate Time Regen Set lt pen Backwash Volume Draw X 1000 Rinse Regen Fill ZART next REGEN Step 4CT Flow AM PM Days To Rate Time Regen Set lt lt ar am Backwash Volume Bw Draw X 1000 Rinse Regen Fill AAA next A REGEN Step 5CT Flow AM PM Days To Rate Time Regen te Set lt Volume X 1000 Regen 0 E Backwash Draw Rinse Fill UK Next A REGEN ei Flow AM PM Days To Rate Time Regen Set lt q Backwash Volume Draw X 1000 E Rinse Regen Fill NEXT A REGEN yEl Flow AM PM Days To Rate Time Regen Set lt a ER Backwash Volu
17. rting the programming steps connect the interconnect cable to each control valve board s three pin connector labeled INTERCONNECT Also connect the meter cord to either control valve to the three pin connector labeled METER Settings eo eg Step 4CS Set regeneration time option to On O Set regeneration time option to On O connector to the two pin connector labeled DRIVE on the ALTA valve Installer Display Step 21 Enter the Volumetric Capacity for the System Enter the Volumetric Capacity for the System the Setting same as Valve A Be Step 31 Set Day Over ride to oFF Set Day Over ride to oFF NOTE If the control valve is in an error state during regeneration mode the MAV will close the B port and keep open the A port until the error is corrected and reset are made nn Set to ALTb Configuration Step5CS ne ida Connect ALTb valve to the MAV s B port No Settings P P P connections between the ALTB valve and the MAV For Clack Corporation alternator systems using the WS1 WS1 25 WS1 5 and WS2L valves the stand by tank will be periodically brought on line for a short time to keep its bed fresh The logic is that once a tank is in standby and the time has passed either 6 AM or 6 PM 18 00 at the next and all subsequent 6 AM and 6 PM times the stand by tank will be brought on line until 10 gallons 37 8 liters has passed through it It will then be placed back on standby For Clack Corporation alt
18. the length of fill from 0 1 99 0 minutes or OFF WS2 valves are shipped from the factory with a refill flow control of 2 2 gpm 8 3 Ipm All other control valves are shipped from the factory with a refill flow control of 0 5 gpm 1 9 Ipm Press NEXT to exit Regeneration Cycle Times Press REGEN to return to previous step EE Manual Page 11 Installer Display Settings One of three sets of displays will be shown depending on what was selected in Configuration Settings Step 3CS Volume Gallons selected in Configuration Settings Step 3CS next Y ReGen nz Step 21 Flow AM PM Days To Rate Time Regen Backwash Draw Rinse Fill REGEN Step 31 PM Days To Time Regen Backwash Draw Rinse Fill DAS A V recen y Flow AM PM Days To Rate Regen Time se lt a Ze Backwash Volume y Draw X 1000 Rinse Regen lt Fill TIAN next Y recen Flow AM PM Days To Rate Time Regen Set lt omy Backwash Volume y Draw EXIT TO X 1000 Rinse DISPLAY Regen al eu Kl SPREENS next REGEN Step 1I To enter Installer Display press the NEXT and A buttons simultaneously for 5 seconds and release Step 21 Volumetric capacity in gallons to regeneration Press NEXT to go to Step 31 Press REGEN to exit