Service bulletin
Contents
1. No Files appear in the connect window beside the STATUS bar the transfer is complete Upon completion reboot the LOGMAN Choose Copy SW PC gt in Command and then press Execute Please note that the LOGMAN internal clock must be updated with GMT time and date before downloading logs In the main menu of the LOGMAN select D LOGMAN functions then C Set Logman time and insert correct date and time GMT time STARCOOL Bjerndrupvej 47 e 6360 Tinglev Denmark e Phone 45 7364 3400 e Fax 45 7364 3569 CVR SE no 13 82 37 74 e starcool starcool dk e www maerskbox com X a Service bulletin M S a Transfer Star Cool controller software to the LOGMAN Download the newest version of Star Cool controller software RCCUOxxx bin from the Star Cool website www starcool dk Save the bin file to a Known folder The software for the different reefer unit controllers are stored on the M disk permanent disk of the LOGMAN 1 Connect the LOGMAN to the PC with the transfer cable 2 Select connect to PC on the LOGMAN by pressing E and use up down arrows to choose PC 112K then press Enter The LOGMAN is now ready to receive the controller software 3 On the PC open the LOGVIEW program In the left side window choose the folder in where you saved the new Star Cool controller software 4 In the toolbar click on Retrieve 5 Click on the
2. i Service bulletin M ey To Service technicians From Star Cool Service Team Date 2007 03 05 Regarding Upload of controller software using the LOGMAN How to upload new controller software to a Star Cool controller The right software in LOGMAN Transfer Star Cool controller software to the LOGMAN Upload new Star Cool controller software with the LOGMAN This instruction requires LOGVIEW preferably the newest version and EPOC CONNECT LITE to be installed in order to communicate with the LOGMAN unit The right software in the LOGMAN In order to communicate with the Star Cool i a controller the LOGMAN needs LOGMAN 2 14 MEE Vhs colle Se software or higher Required programs To install new software in the LOGMAN If old LOGMAN software is still installed on the PC it is suggested to remove delete it first To remove old LOGMAN software from the PC Left click on start go into settings gt control panel Double click on add remove program highlight LOGMAN and press OK This should uninstall the LOGMAN software Download the newest software and run the LOGMAN exe file The LOGMAN software will install itself under C Program files York LOGMAN Srca Before formatting and uploading software to the LOGMAN it is a good idea to replace the main batteries in the LOGMAN If the batteries are low on power it can create difficulties when writing on LOGMAN the disks STARK LOOL Bjerndrupvej 47 e 6360 Ting
3. Psion Link A Psion Link window is now shown 6 Choose Copy CTRL SW PC gt in command and LOGMAN in Device 7 Click on Execute to transfer the software When the Execute button once again is highlighted the transfer is complete STARK LOOL Prepare LOGMAN for PC connection Select Archive Path gt star Cool gt SW ie gt Release ACCU 0240 aa BT R L i Select path to Star Cool controller software Psion Link Command Device copy Logs Peas Locman Copy Logs PCS Copy Cud ote oy sian Copy Setup POC gt Copy si TEPL S Copy CTRL si PC gt Del CTEL SW PEC Format Drive PC Close Execute Cancel Choose Copy CTRL SW PC gt in Command and then press Execute Bjerndrupvej 47 e 6360 Tinglev Denmark e Phone 45 7364 3400 e Fax 45 7364 3569 CVR SE no 13 82 37 74 e starcool starcool dk e www maerskbox com Service bulletin M S a Upload new Star Cool controller software with the LOGMAN With the Star Cool unit connected to main power Connect the LOGMAN to the Star Cool controller via the retriever cable to the retriever port 1 Turn ON the Star Cool unit and the LOGMAN 2 Press E on the LOGMAN and use arrows to choose StarCool RCCU 5 and then press Enter 3 Press D for Logman function then E for Flashload S
4. Press Menu Choose System screen Choose Data gt press Menu Choose Disk gt Format Disk gt ay Bjerndrupvej 47 e 6360 Tinglev Denmark e Phone 45 7364 3400 e Fax 45 7364 3569 CVR SE no 13 82 37 74 e starcool starcool dk e www maerskbox com Service bulletin Upload of new LOGMAN software 1 Switch ON the LOGMAN 2 Open the LOGMAN by pushing the release button on the back side of the LOGMAN 3 Boot the LOGMAN by pushing bottom left key U Ctrl and Del simultaneously Choose System screen 4 Make sure the two solid state discs are not write protected The display should now read Insert Startup autoexe SSD and press Enter or press Menu for System Interface Close the LOGMAN again 5 Push the Menu key Choose Data gt press Menu 6 There are now 4 options shown in the display Choose System Screen by scrolling with the arrow keys and press Enter 7 You can now scroll with the left and right arrow key Choose Data and press the Menu key 8 Scroll with the left or right arrow and place the cursor on the Spec Now use the down arrow and choose Remote link and press Enter Choose Spec gt Remote link gt Remote link 9 In Remote link set it to ON with the left or right key 10 Scroll down with the arrow key to Baud rate Choose
5. ce manual until the display will illuminate 4 Press E on the LOGMAN and use arrows to choose StarCool RCCU 5 and then press Enter 5 Press D for Logman function then E for Flashload StarCool finally choose the letter for the right software to upload RCCUOxxx bin 6 The display now shows Press any key to start flashload 7 Press any key e g Enter once nothing will change in the display Now start the upload of the new controller software by pressing twice on the wake up key 8 The display in the LOGMAN will add Flashloading After a short while the display will add Flashload completed 9 Press ESC to exit the upload screen The Star Cool controller automatically reboots Check that the new software is stated in the start up screen The unit is now updated with the newest controller software Press and hold Wake up key till display illuminates Connect to the Star Cool unit Press e g Enter once then press twice on the wake up key on the Star Cool key pad Flashloading in progress Flashload completed Press ESC on the LOGMAN STAR LOOL Bjerndrupvej 47 e 6360 Tinglev Denmark e Phone 45 7364 3400 e Fax 45 7364 3569 CVR SE no 13 82 37 74 e starcool starcool dk e www maerskbox com
6. lev Denmark e Phone 45 7364 3400 e Fax 45 7364 3569 CVR SE no 13 82 37 74 e starcool starcool dk e www maerskbox com Service bulletin M ey a Format of the A disk can be done in two ways Format of top disk directly with the LOGMAN 1 Open the LOGMAN and by pushing the release button on the back side of the LOGMAN Press left bottom key U Ctrl and Del simultaneously reeboots the LOGMAN Insert Startup autoexec will be displayed 2 Close the LOGMAN and press Menu 3 Scroll down to System screen and press Enter 4 When the icon Data is now highlighted press Menu 5 Scroll right to Disk and scroll down to Format disk and press Enter 6 At Disk select A Top disk which contains the LOGMAN software with the left or right arrow key and press Enter 7 To format the A disk top disk press Y Format of top disk by use of LOGVIEW On the PC open the LOGVIEW program and connect the LOGMAN to the PC with the transfer cable and select connect to PC on the LOGMAN by pressing E and use up down arrows to choose PC 112K then press Enter In the LOGVIEW window Select retrieve gt Psion Link gt Format drive gt pc and press execute Select A top disk and press OK This should format the A disk containing the software STARCOOL Pull out the top disk and reboot
7. tarCool finally choose the letter for the right software to upload RCCUOxxx bin 4 The display now shows Press any key to start flashload 5 Press any key e g Enter once nothing will change in the display Now switch off the Star Cool unit and turn it back on again The display in the LOGMAN will add Flashloading After a short while the display will add Flashload completed 6 Press ESC to exit the upload screen The Star Cool controller automatically reboots Check that the new software is stated in the start up screen The unit is now updated with the newest controller software STARK LOOL Connect to the Star Cool controller Press e g Enter once then switch OFF and then ON the Star Cool unit Flashloading in progress Flashload completed Press ESC on the LOGMAN Bjerndrupvej 47 e 6360 Tinglev Denmark e Phone 45 7364 3400 e Fax 45 7364 3569 CVR SE no 13 82 37 74 e starcool starcool dk e www maerskbox com Service bulletin J p m With the Star Cool unit not connected to main power The Star Cool unit can have software uploaded even though it is not connected to main power 1 Connect the LOGMAN to the Star Cool controller via the retriever cable to the retriever port 2 Turn ON the LOGMAN 3 Turn ON the Star Cool unit by holding the wake up key If in doubt refer to the Operation and servi
8. the highest speed with the right key 115200 Settings to be made in 11 Scroll down with the arrow key to Port and Remote Link gt Enter choose A and press Enter The screen will now go back to the same screen as in number 7 It is now ready to receive software SW can now be transferred to LOGMAN from LOGVIEW STARCOOL Bjerndrupvej 47 e 6360 Tinglev Denmark e Phone 45 7364 3400 e Fax 45 7364 3569 CVR SE no 13 82 37 74 e starcool starcool dk e www maerskbox com 5 Service bulletin M a a oelect Archive Fath e Frogrammer YORK gt LogMan Transfer LOGMAN software to the LOGMAN 1 Connect the LOGMAN to the PC with the transfer cable 2 On the PC open the LOGVIEW program Point Select Archive Path to 3 In the left side window choose C under the the right folder Select Archive drive Double click on the Folder Program Files Double click on the Folder YORK Double click on the Folder LOGMAN Double click Psion Link on the Folder Srca You now have the correct path Command Copy Logs 4 In the toolbar click on Retrieve 5 Click on the Psion Link Del CTRL St Format Drive 6 A Psion Link window is now shown Under the Sa aaa a a command line choose Copy SW PC gt Under Device choose LOGMAN Execute 7 To transfer the software click Execute When