P6248 1.7 GHz (Typical) Differential Probe
Contents
1. Operating Basics This section discusses operating considerations and probing techniques For more detailed information about differential measurements and common mode rejection ratio CMRR see the Reference section on page 17 Input Voltage Limits The P6248 differential probe is designed to probe low voltage circuits Before probing a voltage take into account the limits for maximum input voltage the common mode signal range and the differential mode signal range Maximum Input Voltage The maximum input voltage is the maximum voltage to ground that the inputs can withstand without damaging the input circuitry of the probe CAUTION To avoid damaging the inputs of the P6248 differential probe do not apply more than 25 V DC peak AC between each input and ground Common Mode Signal Range The common mode signal range is the maximum voltage that you can apply to each input with respect to earth ground without saturating the input circuitry of the probe A common mode voltage that exceeds the common mode signal range may produce an erroneous output waveform even when the differential mode specification is met For Specifications refer to page 23 To verify the common mode signal is within specification set the probe to 10 temporarily connect one of the probe inputs to ground and connect the other probe input to one output of the P6248 1 7 GHz Differential Probe Instructions 11 Operating Basics differ
2. Reference This section contains important reference information about differential measurements and how to increase the accuracy of your measurements Problems with Single Ended Measurements While suitable in many applications single ended measurements can present problems in the following situations m When the signal is not referenced to earth ground m When connecting or disconnecting the probe ground distorts the signal m When connecting the signal reference to ground damages or upsets the circuit Differential Measurements Devices designed to make differential measurements avoid the problems posed by single ended systems These devices include a variety of differential probes differential amplifiers and isolators The differential amplifier Figure 6 is at the heart of any device or system designed to make differential measurements Ideally the differential amplifier rejects any voltage that is common to the inputs and amplifies any difference between the inputs Voltage that is common to both inputs is often referred to as the Common Mode Voltage Vcm and voltage that is different as the Differential Mode Voltage Vpm P6248 1 7 GHz Differential Probe Instructions 17 Reference 18 Vout Differential mode DM Common V mode CM Figure 6 Simplified model of a differential amplifier Common Mode Rejection Ratio In reality differential amplifiers cannot reject all of the common mode sign
3. Tektronix service center is located Customer shall be responsible for paying all shipping charges duties taxes and any other charges for products returned to any other locations This warranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care Tektronix shall not be obligated to furnish service under this warranty a to repair damage resulting from attempts by personnel other than Tektronix representatives to install repair or service the product b to repair damage resulting from improper use or connection to incompatible equipment c to repair any damage or malfunction caused by the use of non Tektronix supplies or d to service a product that has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty of servicing the product THIS WARRANTY IS GIVEN BY TEKTRONIX IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE TEKTRONIX RESPONSIBILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES he ee T
4. The lower the impedance of the probe relative to that of the source the more the probe loads the circuit under test and reduces the signal amplitude For a graph of frequency versus input impedance refer to Figure 9 on page 26 P6248 1 7 GHz Differential Probe Instructions Operating Basics Common Mode Rejection The common mode rejection ratio CMRR is the specified ability of a P6248 differential probe to reject signals that are common to both inputs More precisely CMRR is the ratio of the differential gain to the common mode gain The higher the ratio the greater the ability to reject common mode signals Common mode rejection decreases as the input frequency increases Figure 8 on page 26 is a plot of typical CMRR of the probe versus input frequency For a more extended discussion of CMRR see page 18 Probing Techniques to Maximize CMRR The common mode rejection of the probe is highest when using the accessories shown in Figures 4 and 5 These accessories minimize the distance between the probe head and the signal source Figure 4 Using the input lead accessories to achieve high CMRR P6248 1 7 GHz Differential Probe Instructions 15 Operating Basics EN A re IS IC pads being probed Conductive side TD Insulated side of probe tip of probe tip Figure 5 Using the TwinFoot adapter 16 P6248 1 7 GHz Differential Probe Instructions My y
5. regions og Standard North America and Japan ae Option A1 European Option A2 UK Option A3 Australia Option A5 Switzerland 50 Q termination Terminates the output of the 1103 power supply to the required 50 Q if the oscilloscope does not have a 50 Q input setting Order 011 0049 01 50 Q BNC cable Connects to the 1103 output Replacement part number 012 0076 00 IEEE1394 Adapter The IEEE1394 Adapter allows you to probe 7 signals on the bus external to system enclosures without l I disturbing system operation The adapter maintains a balanced 55 Q signal path and can be used in both single ended and differential modes Replacement part number 679 5027 00 Micro KlipChip adapters Use the adapters to probe the leads on integrated circuits that are surface mounted Replacement part number SMK4 package of 4 P6248 1 7 GHz Differential Probe Instructions 7 Getting Started Table 3 Optional accessories and instrument options Cont Accessory Option Description Adjustment tool Use for making internal adjustments to the probe Order 003 0675 01 Calibration data Option 95 Option 95 which must be ordered Calibration at the time of purchase documents the measurements taken Data during calibration Installation Before you connect the output of the P6248 differential probe determine whether or not your oscilloscope has a TEKPROBE interface See Figure 1 Figure 1 Input conn
6. 21 Using the Probe with Other Instruments 21 Specifications seat 23 Warranted Characteristics 23 Typical Characteristics ww 40 er ae ee oes 25 Nominal Characteristics asus a ee aR 28 P6248 1 7 GHz Differential Probe Instructions i Table of Contents List of Figures Figure 1 Input connector of TEKPROBE interface Figure 2 Using the short ground contact Figure 3 Typical probe input model Figure 4 Using the input lead accessories to achieve hish EMRR 4 2 Figure 5 Using the TwinFoot adapter Figure 6 Simplified model of a differential amplifier Figure 7 Twisting the Input Leads Figure 8 Typical Common Mode Rejection Ratio Bl and B10 attenuation Figure 9 Typical differential input impedance versus frequency ana Figure 10 Probe head and compensation box dimensions 13 14 15 16 18 20 26 26 27 P6248 1 7 GHz Differential Probe Instructions S General Safety Summary Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it To avoid potential hazards use this product only as specified Only qualified personnel should perform service procedures To Avoid Fire or Personal Injury Connect and Disconnect Properly Connect the probe output to the measurement instrume
7. 248 probe installed on a Tektronix TDS 694C oscilloscope When the probe is used with another oscilloscope the oscilloscope must have an input impedance of 50 Q The probe must have a warm up period of at least 20 minutes and be in an environment that does not exceed the limits described in Table 4 Specifications for the P6248 differential probe fall into three categories warranted typical and nominal characteristics Warranted Characteristics Warranted characteristics Table 4 describe guaranteed performance within tolerance limits or certain type tested requirements Warranted characteristics that have checks in the Performance Verification section of the service manual are marked with the 17 symbol Table 4 Warranted electrical characteristics Characteristic Description 1 DC attenuation accuracy 2 for input voltages as follows 750 mV 1 and 7 5 V 10 5 for input voltages as follows 850 mV 1 and 8 5 V 10 Maximum non destructive input voltage 25 V pc peak AC between signal and common of the same channel Differential signal range DC coupled 8 5 V at attenuation setting of 10 850 mV at attenuation setting of 1 Common mode signal range DC coupled 7V P6248 1 7 GHz Differential Probe Instructions 23 Specifications Table 4 Warranted electrical characteristics Cont Characteristic Output offset voltage Rise time probe only 1 Common mode rejection rati
8. Instructions Tektronix P6248 1 7 GHz Typical Differential Probe 071 0566 03 Copyright Tektronix Inc All rights reserved Tektronix products are covered by U S and foreign patents issued and pending Information in this publication supercedes that in all previously published material Specifications and price change privileges reserved Tektronix Inc P O Box 500 Beaverton OR 97077 TEKTRONIX TEK and TEKPROBE are registered trademarks of Tektronix Inc KlipChip TwinFoot TwinTip and VariTip are trademarks of Tektronix Inc WARRANTY Tektronix warrants that the products that it manufactures and sells will be free from defects in materials and workmanship for a period of one 1 year from the date of shipment If a product proves defective during this warranty period Tektronix at its option either will repair the defective product without charge for parts and labor or will provide a replacement in exchange for the defective product In order to obtain service under this warranty Customer must notify Tektronix of the defect before the expiration of the warranty period and make suitable arrangements for the performance of service Customer shall be responsible for packaging and shipping the defective product to the service center designated by Tektronix with shipping charges prepaid Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the
9. TION To avoid damaging the input connectors do not insert anything larger than a 0 025 inch square pin into the inputs To prolong the life of the connectors use the tip saver or smooth gold plated pins only Instrument case The instrument case protects the probe from harsh environments and provides room for storing optional accessories Replacement part number P6248 016 1879 XX Calibration certificate A certificate of traceable calibration is Certificate provided with every instrument shipped of Calibration Instructions Provides instructions for operating the P6248 differential probe Replacement part number 071 0566 XX 2 P6248 1 7 GHz Differential Probe Instructions Getting Started Table 1 P6248 features and standard accessories Cont Feature Accessory P6248 1 7 GHz Differential Probe Instructions Description Service manual Provides procedures for verifying the performance adjusting and maintaining the P6248 differential probe Replacement part number 071 0573 XX Probe tip accessory kit This kit contains the accessories listed below in a plastic case For more information on the individual accessories refer to Table 2 on page 4 10 2 gt oO fANMFWOWOANAH O ND Color marker bands Y lead adapters Short ground leads Long ground leads Short ground contacts Spring loaded ground pin TwinTip adapters Longhorn via adapt
10. able of Contents General Safety Summary iii Prelate sence nesei coe Vase OSES a E Sa v Contacting Tektronix Juristen vi Getting Started 324 440 1 Features and Accessories ask een 1 Installations Pires ork ele rie grade sea ee eb Nay Sle 8 Instruments with the TEKPROBE Interface Tektronix TDS 400 500 600 and 700 Series Oscilloscopes 9 Instruments without the TEKPROBE Interface 9 Operating Basics anne a nn 11 Input Voltage Limits ocre art ner 11 Maximum Input Voltage 11 Common Mode Signal Range 11 Differential Mode Signal Range 12 Attenuation Settings 2 6025 Semi irn ech 12 Probe Grounding Au ale ar 12 Input Impedance and Probe Loading 14 Common Mode Rejection cess 28 sK8 2 RR Rare 15 Probing Techniques to Maximize CMRR 15 Reference nee usant less las 17 Problems with Single Ended Measurements 17 Differential Measurements ea os 29 05 t OO ead eae 17 Common Mode Rejection Ratio 18 Assessing CMRR Error ua so ae 18 Input Impedance Effects on CMRR 19 Extending the Input Leads jo ch eee rec 19 Extending the Ground Lead 20 Extending the Probe Output 2 8 a en 20 Terminating the Probe usa sr rat 20 Effect of Extending the Output Cable
11. al The ability of a differential amplifier to reject the common mode signal is expressed as the Common Mode Rejection Ratio CMRR The CMRR is the differential mode gain Apm divided by the common mode gain Ac It is expressed either as a ratio or in dB a dB 201 os MRR 20 log C Acm eye CMRR generally is highest best at DC and degrades with increasing frequency Assessing CMRR Error Figure 8 on page 26 shows the CMRR of the P6248 differential probe This derating chart assumes a common mode signal that is sinusoidal P6248 1 7 GHz Differential Probe Instructions Reference A quick way to assess the magnitude of CMRR error when the common mode signal is not sinusoidal is to connect both leads to the same point in the circuit The oscilloscope will display only the common mode component which is not fully rejected by the probe While this technique may not give you entirely accurate measure ments it does allow you to determine if the magnitude of the common mode error signal is significant Input Impedance Effects on CMRR The lower the input impedance of the probe relative to the source impedance the lower the CMRR See Figure 9 on page 26 Significant differences in the source impedance driving the two inputs will also lower the CMRR Extending the Input Leads At times it may be necessary to extend the probe inputs with wires or a probe tip adapter When you do this you should minimize the lead leng
12. ector of TEKPROBE interface 8 P6248 1 7 GHz Differential Probe Instructions Getting Started Instruments with the TEKPROBE Interface Tektronix TDS 400 500 600 and 700 Series Oscilloscopes On instruments that have the TEKPROBE interface simply connect the probe to the input The TEKPROBE interface provides power selects the correct display scaling and automatically sets the 50 Q termination on the oscilloscope input NOTE TDS 400 and TDS 400A series oscilloscopes do not interpret the scale factor coding of the P6248 differential probe This problem is only apparent when the probe is in the 1 position To correct for this problem divide the measurement or scale factor by 10 when you use the probe in the 1 position Instruments without the TEKPROBE Interface On instruments that do not have the TEKPROBE interface you must order the optional 1103 power supply refer to page 7 Each 1103 can supply power for two probes The input of the oscilloscope must also terminate into 50 Q Refer to page 20 for information on the effects of extending the output of the probe When you set the attenuation of the probe you must factor that attenuation into your measurement For example if the probe is set at 10 and the instrument displays a 0 2 Vp p signal the actual amplitude of the signal is 2 Vp p P6248 1 7 GHz Differential Probe Instructions 9 Getting Started 10 P6248 1 7 GHz Differential Probe Instructions MER 7
13. ential signal Repeat the procedure to test the other output of the differential signal Differential Mode Signal Range The differential mode signal range is the maximum voltage difference between the and inputs that the probe can accept without distorting the signal The distortion from a voltage that is too large can result in an invalid measurement For Specifications refer to page 23 Attenuation Settings The differential probe has two attenuation settings 1 and 10 The 1 setting provides the best signal to noise performance with low amplitude signals The 10 setting increases the differential mode signal range by a factor of 10 Probe Grounding A 12 In addition to the and inputs on the probe head there is also a ground common input See Figures 2 and 3 CAUTION To avoid damaging the circuitry under test connect the probe ground common to a ground reference point only You can use the probe to take a differential measurement regardless of whether or not the ground common is connected There are some applications that may require a ground reference connection to maintain measurement accuracy Generally this is necessary when probing circuits which are fully isolated from ground such as battery operated devices In most applications however the common mode impedance to ground is greater than the differential impedance Hence adding the probe ground lead does not improve the high frequenc
14. ers Straight tip adapters VariTip adapters TwinFoot adapters Tip savers SMT KlipChip adapters Probe tip to BNC adapter Replacement part number 020 2328 XX Getting Started Table 2 describes the contents of the probe tip accessory kit Table 2 P6248 Probe tip accessory kit contents Accessory Color marker bands A Description Color marker bands Attach matching pairs of the color marker bands onto the cable at the head and compensation box of each probe The marker bands enable quick verification of which probe is connected to which instrument channel Replacement part number 016 1315 00 package of 10 Lead set accessory kit Includes 2 Y lead adapters 4 three inch ground leads and 2 six inch ground leads Replacement part number 196 3462 00 Y lead adapter The Y lead adapter plugs directly into the probe The socketed ends of the leads may be connected to the probe tips and accessories or fitted onto 0 025 inch pins Ground leads Use the ground leads for connecting the probe ground to the circuit The socketed end of the lead may be connected to the probe tips and accessories or fitted onto 0 025 inch pins Short ground contact Use the short ground lead for probing small geometry components that have a nearby ground point The ground easily connects to adjacent square pins when the probe is plugged directly onto 0 025 inch square pins 0 100 inch spacing See Figure 2 on page 13 Replaceme
15. ion ratio Bandwidth probe only Random noise Input impedance Pass band ripple P6248 1 7 GHz Differential Probe Instructions Description 200 kQ 2 100 KQ 2 lt 1 pF at 1 MHz lt 2 pF at 1 MHz lt 1 5 measured using 354 mV Rus or 1 0 Vp p output at 100 MHz 700 mV 1 7V 10 See Figure 8 DC to 1 7 GHz 3dB lt 27 C 1 DC to 1 85 GHz 3dB lt 27 C 10 lt 50nV VHz at 100 MHz See Figure 9 lt 0 25 dB to the 3 dB bandwidth devi ation from a nominal slope 25 Specifications 0 300 M 600 M 900 M 1 2G 15G 18G 2G Frequency Hz Figure 8 Typical Common Mode Rejection Ratio 1 and 10 attenuation Impedance 2 100 k 10k 1k 100 10 0 250M 500M 750M 1G 125G 150G 1 75G 2G Frequency Hz Figure 9 Typical differential input impedance versus frequency The graph in Figure 9 represents simulation results of a first order model of the probe input 26 P6248 1 7 GHz Differential Probe Instructions Specifications Table 6 Typical mechanical characteristics Dimensions input connection 0 63 mm 0 025 in square pin on 2 54 mm 0 100 in centers Dimensions control box 107 mm x 41 mm x 26 mm 4 2 in x 1 6 in x 1 0 in Dimensions probe head 78 mm x 12 mm x 9 3 mm 3 0 in x 0 47 in x 0 36 in Dimensions output cable 1 2 m 47 in Unit weight probe only 160 g 5 4 oz Figu
16. nt before connecting the probe to the circuit under test Disconnect the probe input and the probe ground from the circuit under test before disconnecting the probe from the measure ment instrument Observe All Terminal Ratings To avoid fire or shock hazard observe all ratings and markings on the product Consult the product manual for further ratings information before making connections to the product Connect the ground lead of the probe to earth ground only Do Not Operate Without Covers Do not operate this product with covers or panels removed Do Not Operate With Suspected Failures If you suspect there is damage to this product have it inspected by qualified service personnel Do Not Operate in Wet Damp Conditions Do Not Operate in an Explosive Atmosphere Keep Product Surfaces Clean and Dry Safety Terms and Symbols Terms in This Manual These terms may appear in this manual A WARNING Warning statements identify conditions or practices that could result in injury or loss of life P6248 1 7 GHz Differential Probe Instructions ill General Safety Summary AN CAUTION Caution statements identify conditions or practices that could result in damage to this product or other property Terms on the Product These terms may appear on the product DANGER indicates an injury hazard immediately accessible as you read the marking WARNING indicates an injury hazard not immediately accessible as you read the ma
17. nt part number 016 1783 00 package of 10 Spring loaded ground pin Use the spring loaded ground when probing components that have a nearby ground point Replacement part number 016 1782 00 package of 6 P6248 1 7 GHz Differential Probe Instructions Getting Started Table 2 P6248 Probe tip accessory kit contents Cont Accessory P6248 1 7 GHz Differential Probe Instructions Description TwinTip adapter This accessory provides two adjustable tips for probing connections that are close to each other Replacement part number 016 1786 00 package of 4 Longhorn via adapter This accessory is similar to the TwinTip adapter but it has finer pins for probing smaller holes Use this accessory for probing circuit board through holes vias Replacement part number 016 1780 00 package of 5 Straight tip adapter The straight tip adapters plug directly into the probe and allow you to take measurements from two points spaced 0 100 inches apart Use the straight tip adapters when you need to measure fast waveforms that may be affected by the longer length of other adapters Replacement part number 016 1891 00 package of 8 VariTip adapter The VariTip adapters plug into the probe and allow you to measure two test points spaced between 0 020 and 0 180 inches apart Use tweezers to adjust the spacing between the pins Use the VariTip adapters to probe waveforms that have fast rise times The short length of the Va
18. o Bandwidth probe only Temperature Humidity 1 See warning that follows Description 10 mV 20 C to 30 C 68 F to 86 F 50 mV 0 C to 60 C 32 F to 122 F lt 265 ps 45 dB at 1 MHz in 10 25 dB at 100 MHz in 10 20 dB at 500 MHz in 10 18 dB at 1 GHzin 10 60 dB at 1 MHz in 1 38 dB at 100 MHz in 1 35 dB at 500 MHz in 1 30 dB at 1 GHz in 1 DC to gt 1 5 GHz 3dB Operating 0 to 50 C 32 to 122 F 0 to 60 C 32 to 140 F probe head Nonoperating 55 to 75 C 131 to 167 F Operating 0 90 RH tested at 30 to 50 C 68 to 122 F Nonoperating 0 90 RH tested at 30 to 60 C 68 to 140 F WARNING To avoid a burn hazard at high ambient temperatures do N not touch the probe with bare hands at operating temperatures above 50 C or at nonoperating temperatures above 70 C Allow sufficient time for the probe to cool before handling 24 P6248 1 7 GHz Differential Probe Instructions Specifications Typical Characteristics Typical characteristics Tables 5 and 6 describe typical but not guaranteed performance Table 5 Typical electrical characteristics Characteristic Differential input resistance DC coupled Common mode input resistance DC coupled Differential input capacitance Common mode input capacitance Harmonic distortion Differential offset range Common mode reject
19. obe has a bandwidth of 1 5 GHz 1 7 GHz typical The probe has low circuit loading high common mode rejection and comes with accessories that accommodate a wide variety of applications The TEKPROBE interface is standard on Tektronix TDS series oscilloscopes The Tektronix 1103 TEKPROBE Power Supply can be used for instruments without the TEKPROBE interface refer to page 7 Features and Accessories Table 1 shows the features and standard accessories of the P6248 differential probe Table 1 P6248 features and standard accessories Feature Accessory Description TEKPROBE interface The TEKPROBE interface supplies power to the probe selects the correct display scaling and automatically sets the 50 Q termination on the oscilloscope input If your oscilloscope does not have the TEKPROBE interface you can use the optional 1103 power supply refer to page 7 Probe attenuation The attenuation switch selects either divide by 1 1 or divide by 10 10 ATTENUATION 10 m 41 P6248 1 7 GHz Differential Probe Instructions 1 Getting Started Table 1 P6248 features and standard accessories Cont Feature Accessory Description Ground Input connections The and ground connections of the probe head accept the standard and optional probe accessories You can also plug the head directly onto a pair of 0 025 inch square pins that have the standard spacing of 0 100 inch on center CAU
20. re 10 Probe head and compensation box dimensions P6248 1 7 GHz Differential Probe Instructions 27 Specifications Nominal Characteristics Nominal characteristics Table 7 describe guaranteed traits but the traits do not have tolerance limits Table 7 Nominal electrical characteristics Input configuration Differential two inputs and with case ground Output coupling DC Attenuation settings 1 and 10 Termination Terminate output into 50 Q 28 P6248 1 7 GHz Differential Probe Instructions
21. riTip adapters minimize the effects of increased probe tip inductance and capacitance on your measurements Replacement part number 016 1890 00 package of 8 TwinFoot adapter Use the TwinFoot adapter to probe two adjacent leads on a surface mount integrated circuit Flexible fingers adapt to a range of lead spacings See Figure 5 on page 16 Replacement part number 016 1785 00 package of 4 Getting Started Table 2 P6248 Probe tip accessory kit contents Cont Accessory Description Tip saver Use the tip saver to prolong the life of your probe tip contacts The tip saver connects to the probe and accepts the probe tip accessories bearing the wear of repeated connections of different probe tips Replacement part number 016 1781 00 package of 2 SMT KlipChip adapters Use this accessory to probe the leads on dual in line packages DIP Replacement part number 206 0364 XX Probe tip to BNC adapter This accessory adapts the probe to a BNC connector Replacement part number 679 4094 00 P6248 1 7 GHz Differential Probe Instructions Getting Started Table 3 shows the optional accessories that you can order for the P6248 differential probe Table 3 Optional accessories and instrument options Accessory Option Description 1103 Power supply Order the 1103 power supply for instruments that do not have the TEKPROBE Interface Power cord options are available for the following countries or
22. rking CAUTION indicates a hazard to property including the product Symbols on the Product These symbols may appear on the product N CAUTION Protective Ground Refer to Manual Earth Terminal P6248 1 7 GHz Differential Probe Instructions EEE Preface This manual contains instructions and specifications for using the P6248 differential probe Related Manuals For performance verification procedures adjustment procedures a list of replaceable parts and other service information refer to the P6248 Service Manual 071 0573 XX P6248 1 7 GHz Differential Probe Instructions V Preface Contacting Tektronix Phone Address Web site Sales support Service support Technical support 1 800 833 9200 Tektronix Inc Department or name if known 14200 SW Karl Braun Drive P O Box 500 Beaverton OR 97077 USA www tektronix com 1 800 833 9200 select option 1 1 800 833 9200 select option 2 Email techsupport tektronix com 1 800 833 9200 select option 3 6 00 a m 5 00 p m Pacific time This phone number is toll free in North America After office hours please leave a voice mail message Outside North America contact a Tektronix sales office or distributor see the Tektronix web site for a list of offices vi P6248 1 7 GHz Differential Probe Instructions i A Getting Started The P6248 is a high bandwidth differential probe with the TEK PROBE interface The P6248 pr
23. t a 50 Q coaxial terminator on the input P6248 1 7 GHz Differential Probe Instructions Reference Effect of Extending the Output Cable As the frequency of a signal increases current flow concentrates at the outer edges of the conductor effectively increasing the impedance This effect is known as skin loss The P6248 probe contains circuitry to compensate for skin loss The compensation provides flat response with the probe cable Extending the length of the output cable increases the amount of skin loss beyond the range of compensation correction Minimizing the length of cable extension reduces the attenuation In critical applications which require high amplitude accuracy you should first characterize the response of the probe with the extension using a leveled signal source and power meter Then you can factor the characterization results into the measurement Using the Probe with Other Instruments Besides the oscilloscope it is possible to use the P6248 differential probe with other types of measurement instruments such as spectrum analyzers time internal analyzers and network analyzers When using the differential probes with these instruments you must normalize the probe with the instrument before making a measure ment P6248 1 7 GHz Differential Probe Instructions 21 Reference 2 P6248 1 7 GHz Differential Probe Instructions Eyes Specifications The specifications in Tables 4 through 7 apply to a P6
24. ths to optimize common mode rejection and twist the input leads together as shown in Figure 7 Twisting the input leads together does increase capacitance that may degrade high frequency performance You should take into account any effects caused by the extended leads when you take a measure ment CAUTION To avoid damaging the input connectors do not insert anything larger than a 0 025 inch square pin into the inputs Use the tip saver accessory to preserve the integrity of the input connectors P6248 1 7 GHz Differential Probe Instructions 19 Reference Figure 7 Twisting the Input Leads Extending the Ground Lead Extending the ground lead will have little if any affect on your measurements In most circuits the ground path from the differential source has sufficiently high impedance to damp out any ringing caused by lead inductance Extending the Probe Output 20 With the 1103 TEKPROBE power supply it is possible to extend the output of the probe in order to connect the probe to other types of measurement instruments or simply to connect the probe to a signal source that is outside the reach of the probe Terminating the Probe The probe must terminate into 50 Q at the input of the measurement instrument Use the 1103 TEKPROBE power supply to adapt the differential probe and set the input impedance of the measurement instrument to 50 Q If the measurement instrument does not support 50 Q input termination connec
25. y performance of the measurement P6248 1 7 GHz Differential Probe Instructions Operating Basics In addition to the 6 inch ground lead there are other ground lead accessories that are useful in certain applications Figure 2 shows how to use the short ground contact Figure 4 on page 15 shows the spring loaded ground pin Wor Figure 2 Using the short ground contact P6248 1 7 GHz Differential Probe Instructions 13 Operating Basics Input Impedance and Probe Loading 14 When you connect the probe inputs to a circuit you are introducing a new resistance capacitance and inductance into the circuit Each input of the P6248 differential probe has a characteristic input impedance of 100 kQ to ground in parallel with less than 1 pF See Figure 3 For signals with low source impedance and frequency the 100 kQ input impedance on each input is large enough to prevent the inputs from loading the signal sources The greater the source impedances and the higher the signal frequencies the more you should take these factors into account Input T Ground 1 5 pF 0 25 Le Input lt a Figure 3 Typical probe input model As the impedance of the signal source on an input increases the more the probe loads the source and reduces the signal amplitude The frequency of the signal also affects signal measurement As the frequency of the signal increases the input impedance of the probe decreases
Download Pdf Manuals
Related Search
Related Contents
Sagem PPF675 Magic 5 An Innovative Design Initiative for Preventing And Or Interrupting C-700 UZ Reference Manual Instruction Manual.0 Instruction Manual - Case Nachhaltig bauen 2012 Amazilla iWing SR-HD Motori pneumatici per avvitare ALFB FR Frigidaire 12 cu. ft. / 340 liter Upright Freezer FFU12C2A Copyright © All rights reserved.