VCP-8101 Vacuum Pump

image

Contents

1. 4 31 Cable protector 1 l S S Figure 2 Pump connected to Filtration Device with Reservoir and Neutralizer 2 E TT g i A gt pa Warranty Statement LMS guarantees that the device is free from manufacturing defects when shipped from the factory Should there be any manufacturing defects LMS will replace the device or repair the defect within 12 months from the date of purchase Warranty does not cover units with damaged manufacturer s label damaged seals damage through improper use and improper storage Warranty does not cover parts damaged through normal wear and tear No service manual is available If the unit is dismantled for any reason except by the manufacturer or personnel authorized by the manufacturer all warranties are null and void Warranty claims and service requests must be made through the distributor from whom you purchased the unit Name of Distributor Address Model Number Description Serial Number Date of Sale LMS CO LTD Tanaka Bldg 3 6 7 Hongo Bunkyo ku Tokyo JAPAN Tel 813 5842 41 71 Fax 813 5842 4180 E mail info group lms com
2. VACUUM PUMP Model VCP 8101 Thank you for choosing the LMS Model VCP 8101 Vacuum Pump Your Vacuum Pump is CE Certified and designed to be safe reliable and easy to operate Please read this thoroughly before operating the Vacuum Pump Failure to observe the instructions may cause damage to the equipment Features Basic Vacuum Pump for laboratory applications Oil less and low maintenance Low noise level 55qB to 60 dB during operation Large rubber feet add stability and act as vibration dampers Easy replacement of moisture trap and filter Vacuum level adjustable up to 650 mm Hg High flow rate Convertible to pressure pump with optional pressure kit 2 years warranty against defects excludes consumables APPLICATIONS Vacuum Filtration Vacuum Dessicators and Cabinets TLC Sprayers Vacuum Ovens partial evacuation SPECIFICATIONS N VV A 5Tkg 272 W x121 D x164 H mm 178 NPT Based on evacuating a 2 liter Vacuum Dessicator PS 1OOmMMHg 13 33kpa 1L min 0 035CFM Pre Operation Checks 1 Place and operate your Vacuum Pump on a clean level surface preferably in a well ventilated area 2 Connect a vacuum tubing to the vacuum inlet of the Vacuum Pump Clips are not required when the Pump is used for vacuum 3 Loosen the Drain Valve to release any vacuum within the system and to drain any water in the moisture trap 4 Connect the Power Cable to a grounded power outlet Oper
3. ation 1 Turn on the power to the Vacuum Pump if necessary 2 Switch the Vacuum Pump on using the power switch located at the top of the unit 3 Tighten the Drain Valve 4 During operation it is normal for the Vacuum Pump to become hot Refrain from touching the metal parts during operation to avoid getting burnt 5 The Vacuum Pump is not designed for prolonged periods of continuous use A thermal switch cuts off power when the Vacuum Pump gets too hot to prevent internal damage 6 The VCP 8101 Vacuum Pump is designed to evacuate air only When operating as a vacuum source for liquid filtration it must be used with a reservoir between the filter and the Vacuum Pump see Figure 2 7 Ensure that no liquid enters the pump Liquid inside the pump voids the warranty 8 When used to provide vacuum for acidic filtration a suitable neutralizer must be placed between the reservoir and the Pump see Figure 2 9 The VCP 8101 is not designed to be used with corrosive and explosive media Failure to heed this instruction may result in equipment damage and personnel injury 10 Glassware and apparatus used in the setup must be designed for use with vacuum to prevent damage and injury caused by imploding glassware 11 After operation the power should be turned off and the Drain Valve opened Pressure 1 While the VCP 8101 is designed primarily as a Vacuum Pump it can be used to provide pressure with an optional Pressure Kit 2 When use
4. d for pressure the tubing ends must be securely clamped Clips not supplied 3 Glassware and apparatus used in the setup must be designed for use with pressure to prevent damage and injury caused by exploding glassware Maintenance 1 This is an Oil less Vacuum pump The use of lubricants can cause damage to the pump and voids the warranty 2 The Pump should be routinely cleaned with a clean and damp cloth Do not use chemical and abrasive cleaners on the pump 3 Check the condition of the Moisture Trap Filter and Power Cord regularly Figure 1 Parts of the Vacuum Pump HARMONY VACUUM PUMP 284 MODEL VCP 8101 sa 65 40 41 42 Q t Q ty Index Q t 1 Setscrew 4 17 Cylinder 1 33 Condenser 2 Fancover 1 18 Valveplate 2 34 OnOff Switch 1 3 Coolingfan 1 19 Valveplatelock __ 2 35 Plug J1 4 Rearbody 1 20 Setscrew 2 36 Airintake filter 1 5 Setscrew 2 21 Paperpad 1 37 Condensercover 1 6 Stationarymotor 1 22 Frontbodylid 1 39 Connecting Rod 1 7 Bearng 2 23 Setscrew f4 40 Pressuregauge 1 8 Rotary Motor 1 24 Oring 1 4 _ Moisturetrap 1 9 FrontBody 1 25 Cylinderblock_ 1 42 Drainvalve 1 410 Counterweight 1 26 Orin J1 48 Isolation J1 12 Bearing 1 27 Cylinderhead 1 65 Tierconnector _ _ 1 Compressing ring 1 28 Setscrew 4 66 Airfilter airinlet 1 415 Lockplae 1 f30 _ Handle ft S S 416 Rubberstand

Download Pdf Manuals

image

Related Search

Related Contents

ページプリンタの表示に関するガイドライン  "取扱説明書"  

Copyright © All rights reserved.
Failed to retrieve file