Home
        SERVICE MANUAL - Appliance Factory Parts
         Contents
1.     6  Press TIMER  Timer On indicator light will flash  Display will show remaining hours before the air conditioner  will turn on    7  Press the TEMP TIME up or down arrow button to change the delay time from 1 hour to 24 hours     8  After 5 seconds  Timer On indicator light will remain on  Display will show the current room temperature     To clear Timer delay program    NOTE Air conditioner can be either on or off    1  Press TIMER once after it has been programmed  Display will show remaining time    2  While the display is showing the remaining time  press TIMER again  Timer Off indicator light will turn on   To see or change the remaining time  in hours     1  Press TIMER once after it has been programmed  Display will show remaining time                        EE  Haier Domestic Air Conditioner    Haier           ESA08               and Functions    2  While the display is showing the remaining time  press the up or down TEMP TIME button to increase or  decrease the time   3  After 5 seconds  the display will show the current room temperature     Using the Remote Control    NOTE Remote control may differ in appearance     ON OFF  S  CH Move  E SPEED  ZEE           EA   TEMP TIME  TEMP TIME    Haier    NOTE One CR2025 battery  included  powers the remote control  Replace battery after 6 months of use  or  when the remote control starts to lose power     Power    Press ON OFF to turn on the air conditioner   ON OFF  Mode    Press MODE to choose Fan  Cool  Energy Saver
2.     Approved by  Wang Xi Bo    Domestic Air Conditioner    
3.   Press SPEED to select High  Med or Low fan  speed  Because the fan does not circulate the room air continuously  less energy is used  but the room  air is not circulated as often    m Dehum   Dries the room  The air conditioner automatically selects the temperature  Fan runs on Low  speed only    NOTE Dehum mode should not be used to cool the room     MODE    CC ran              ENERGY   Ce    beEnum    NOTE  After 5 seconds  display will show the current room temperature     Fan Speed    NOTE In Dehum mode  the Speed button will not operate   1  Press FAN SPEED until you see the indicator light glow for the desired setting     2  Choose High  Med or Low   m High   for maximum cooling  m Med   for normal cooling  m Low   for minimum cooling    SPEED                              Low    NOTE After 5 seconds  the display will show the current room temperature     Temperature    m Pressthe TEMP TIME up arrow button to raise the temperature  Each time you press or hold the TEMP TIME  up arrow button  the temperature will go up 1 F until it reaches 86  F  30 C      NOTE After 5 seconds  the display will show the current room temperature     UE  Haier Domestic Air Conditioner    Haie          ESA08         J  PartdandFunctions     A  TEMP TIME         m Press the TEMP TIME down arrow button to lower the temperature  Each time you press or hold the TEMP TIME  down arrow button  the temperature will go down 1  F until it reaches 61  F  16  C    NOTE After 5 seconds  the display will
4.  3 3  1 e e 1  fT e c CH                 1 1  E                                 E  E  2i ET   EZ Ut pa pa    S E E 2    a e    t   gt   gni     3 3 E  E  amp  4 4  10070 As  M oot T   Real E E X 5 E E 2        H bo        B    T   T 1   T   T   T     Tx  12           wien  LMS 9MS SMS A EMS TMS IMS 8A           lux  AON dads WANIL An  HAIL dWRl                   1904 DRLOSISSINE            anto anyo SS    12  TID                                  y X01  GE d       AS    21    Domestic Air Conditioner    Haier    ircuit Diagram          ESA408J    Haier    0SCT A 8 Ost 1  8  OINO    OOVFZ68 VS ACI    0SCT A 8 O  tI  8  6NO    JOVFEC68 VS ACI    OSCT A 8 Ost I  8  8NO    OOVFEC68 VS ACI                                                                                                                                                                                                                                                                                                                                                                   LAM 12                 08        1                                 ED      owvrami6evscAzil   1 l        d d     Ir  T      ATI                           e  12209    LU  S080 31 6  4                                    YHX gza CH i 01   I    AO0S InZ v      SI N     ENO TE 6 022 ou         m            ATI   ATI                 TH      3L  eme geg TI   AS  ER                 TNI         24 LE  6080   1  S IET 0 5  E         END  COVAOTT   de    B Ae 
5.  Timer to turn on the air conditioner  changing the previous settings    1  Turn on the air conditioner    2  Adjust the mode to Fan  Cool  Energy Saver or Dehum    3  For Fan  Cool or Energy Saver mode  adjust the fan speed to High  Med or Low   NOTE In Dehum mode  the Speed button will not operate     4  Adjust the temperature between 61  F and 86  F  16  C and 30  C    NOTE In Fan mode  the temperature cannot be set    5  Wait 3 seconds before turning off the air conditioner    6  Press TIMER  Timer On indicator light on the air conditioner control panel will flash  Display will show remaining  hours before the air conditioner will turn on    7  Press the TEMP TIME up or down arrow button to change the delay time from 1 hour to 24 hours    8  After 5 seconds  Timer On indicator light on the air conditioner control panel will remain on  Display will show    the current room temperature     To clear Timer delay program                 conditioner can be either on or off     1  Press TIMER once after it has been programmed  Display on the air conditioner control panel will show  remaining time     2  While the display is showing the remaining time  press TIMER again  Timer Off indicator light will turn on     To see or change the remaining time  in hours      1  Press TIMER once after it has been programmed  Display on the air conditioner control panel will show  remaining time    2  While the display is showing the remaining time  press the TEMP TIME up or down arrow button 
6.  drill bit to drill a starter hole through the holes in the side bracket and windowsill   6  Using two  32    screws  attach the side bracket to the windowsill     ll       NN             7  Repeat for side bracket installation on the left hand side of the air conditioner     Attach Side Curtains to Window    1  Pull the left hand curtain out until it fits into the window channel   2  Use         drill bit to drill a starter hole through the top hole in the side curtain and into the window sash     3  Insert one of the  732  screws through the top hole of the lefthand curtain and into the window sash   4  Repeat for the right hand curtain     5  Use a8  drill bit to drill a starter hole through the bottom hole in the side curtain and into the window frame     6  Insert one of the  732   screws through the bottom hole of the left hand curtain and into the window frame           Repeat for the right hand curtain     __ N  Haier Domestic Air Conditioner    Haier ESA408J Installation and Accessory Parts    Top View                Bottom View                                                                                                                                                           Complete Installation    1  Insert the foam seal behind the top of the lower window sash and against the glass of the upper window             A  Top of lower window sash  B  Foam seal    2 Place the window lock bracket as shown  Use      8  drill bit to drill a starter hole through the hole
7.  in the window lock  bracket and into the upper window     3  Attach the window lock bracket to the upper window with           32  screw to secure the window in place   4  Plug into a grounded 3 prong outlet   5  Press RESET on the power supply cord  See  Electrical Requirements      Haiet   Domestic Air Conditioner             Haier ESA408J Installation and Accessory Parts    Parts    Check that all parts are included in parts package                        CR2025    55  battery SC  TIMER  vn       Haier  H 1      Top channel ESA408J ESA408J L 3   B  Foam seal ESA408J T 3   C  Side brackets  2     3732   screws  9   D Window lock bracket G  Side curtains  2        732     screws   H  Side curtain frames  2     1  Remote control    Tools    Phillips head screwdriver  Flat blade screwdriver  Scissors   Level   Socket wrench and sockets  Tape measure   Cordless drill and 1 8  bit  Pencil   Pliers   Adjustable wrench    13  Haier Domestic Air Conditioner    Haier ESA408J Partd and Functions    6 Partd and Functions    Mode    1  Press MODE until you see the indicator light glow for the desired setting     2  Choose Fan  Cool  Energy Saver or Dehum   wm Fan   Only the fan runs  Press SPEED to select High  Med or Low fan speed  The display shows the    current room temperature    m Cool   Cools the room  Press SPEED to select High  Med or Low fan speed  Press the TEMP TIME up  or down arrow button to adjust the temperature       Energy Saver   Fan runs only when cooling is needed
8.  or Dehum     m MODE  m           se 9          gt  9    Speed  Press SPEED to choose High  Med or Low     ES SPEED    Temperature       Press the TEMP TIME up arrow button to raise the temperature  Each time you press or hold the TEMP TIME up arrow button   the temperature will go up 1  F until it reaches 86  F  30  C      TEMP TIME       Press the TEMP TIME down arrow button to lower the temperature  Each time you press or hold the TEMP TIME down arrow  button  the temperature will go down 1  F until it reaches 61  F  16  C      TEMP TIME  16    Haiee   00 Domestic Air Conditioner    Haie        ESMO    3        J  PartdandFunctions    Timer    To set the Timer for a 1 hour to 24 hour delay before the air conditioner is turned off  the air conditioner must be On      1  Press TIMER  Timer On indicator light on the air conditioner  control panel will flash     en TIMER  NE         2  Press the TEMP TIME up or down arrow button to change the delay time from 1 hour to 24 hours     3  After 5 seconds  Timer On indicator light on the air condition control panel will remain on     To set Timer to turn on the air conditioner  keeping previous settings     1  Turn on the air conditioner    2  Press TIMER  Timer On indicator light on the air conditioner control panel will flash    3  Press the TEMP TIME up or down arrow button to change the delay time from 1 hour to 24 hours   4  After 5 seconds  Timer On indicator light on the air conditioner control panel will remain on     To set
9.  show the current room temperature     Timer Delay    To set the Timer for a 1 hour to 24 hour delay until the air conditioner turns off  the air conditioner must be On      1  Press TIMER  Timer On indicator light will flash  Display will show remaining hours before the air conditioner  will turn off     TIMER       on               2  Press the TEMP TIME up or down arrow button to change the delay time from 1 hour to 24 hours   3  After 5 seconds  Timer On indicator light will remain on  Display will show the current room temperature     To set the Timer to turn on the air conditioner  keeping previous settings     1  Turn on the air conditioner     2  Press TIMER  Timer On indicator light will flash  Display will show remaining hours before the air conditioner will  turn on   3  Press the TEMP TIME up or down arrow button to change the delay time from 1 hour to 24 hours     4  After 5 seconds  Timer On indicator light will remain on Display will show the current room temperature   To set the Timer to turn on the air conditioner  changing the previous settings     1  Turn on the air conditioner   Adjust the mode to Fan  Cool  Energy Saver or Dehum   For Fan  Cool or Energy Saver mode  adjust the fan speed to High  Med or Low     em    NOTE   In Dehum mode  the Speed button will not operate     Adjust the temperature between 61  F and 86  F  16  C and 30  C      NOTE In Fan mode  the temperature cannot be set           5  Wait 3 seconds before turning off the air conditioner
10.  with a properiy grounded outlet      Do not  under any circumstances  cut or remove the third  ground  prong from the  power cord     Adapter Plug  We strongly advise against using an adapter plug      Haiet    Domestic Air Conditioner    ESA408J Warning and Cautions       This air conditioner is designed for use in a double hung window    While installing unit be sure to tilt air conditioner 5 degrees outward to have the water drip outside the    house    Install the unit on the north side   as that is normally the shaded side   This will enhance the operation    of your unit    The window has to be strong for installation   Extra brackets and or support may be required depending  on your window   Brackets and supports not included in all models       Measure the window before installing   If the window is too big for the unit you may require professional  installation   Use the correct electric voltage and proper ampere for the unit to run effectively      Only let a certified electrician modify your electrical outlet      Use a dedicated line for the operation of your air conditioner to avoid the possibility of an electrical surge     Energy Saving Guide    Haier    When installing your air conditioner   make sure to seal all areas where there is a possibility of air leakage      The airflow should not be blocked   either inside by curtains   drapes or furniture   or outside by shrubs or  bushes     Do not needlessly use electrical light or other appliances that produce h
11. 20                         D 21  0  Wiring  DIAG               e               23    Haiet          Domestic Air Conditioner    Haief ESA408J Illumination and introduction    1 Product Code Illumination and Series introduction    1   Model identification     ESA  1                  C D  A  Abbreviation of Energy Star  B  The type of refrigerant  4  RA10A  C  Nominal cooling capacity  BTU h  with the first two numbers based on one thousand  unit  D  Design code    Examples   ESA408J    It represents remote control window air conditioner  Cooling capacity is 8000BTU h and  the refrigerant is RA10A      2   Standard situation conditions                   No Opdralina condition Indoor air state outdoor air state             DB C   WB C   DB C             1 Nominal cooling 26 7 19 4 35 23 9                      Haiee i Domestic Air Conditioner    Haief    ESA408J Specification  2 Specification  Item Unit ESA408J  Cooling capacity BTU h 8000  Heating capacity BTU h    Power supply 1PH 115V 60HZ  Power input W 740  Cooling Running current A 6 7  EER BTU  h W  10 8  Power input W    Heating Running current A           BTU  h W     Indoor side dB A  63         Outdoor side dB A  67  Height inches 12 7 16  Net dimensions Width inches 18 1 2  Depth inches 14    Height inches 15  deed Width inches 20 1 4  Depth inches 17 3 4  Net kg 22  Mech Gross kg 24  Type Rotary  Compressor Model   39A171A  Running cap  For comp       35uF 250V  Pressure Hi Pressure Psig 500  Low Pressure Psig 240  R
12. 22 or  Refrigerant Ge R410A                        OZ 20 1  Type Indoor unit   centrifugal  Fan Outdoor unit   axial  Fan Speed   Indoor unit r min 1500 1300 1100  Air volume CFM 195 170 145  Moisture removal Pints hr 2 5    Haier                                                                                                                         Domestic Air Conditioner    Haier ESA408J Safety and Precaution       3  Safety and Precaution    A    Haier    WARNING  Following these basic precautions will reduce the risk of fire  electrical shock  injury or death  when using your air conditioner      1  Air conditioner must be connected to proper electrical outlet with the correct electrical supply     2  Proper grounding must be ensured to reduce the risk of shock and fire     DO NOT CUT OR REMOVE THE GROUNDING PRONG    If you do not have a three prong electric receptacle outlet in the wall  have a certified electrician install the  proper receptacle   The wall receptacle MUST be properly grounded      3  DO not use if power cord is frayed or damage   Also avoid using if there are cracks or abrasion damage  along the length  plug or connector      4 DO NOT USE AN ADAPTER OR AN EXTENSION CORD     5 When installing your air conditioner in a window make sure the window is strong enough to hold the weight  of the air conditioner  You also want to secure and correctly install your air conditioner property to prevent it  from falling Extra brackets or support may be required depen
13. Haier SERVICE MANUAL    Order No AC0911S007V0       Model No  ESA408J    CES  a  B   GE  n    mn      Feature    Haier          Top Discharge Airflow Pattern  Modern Family look Design   3 Cool Settings  3 Fan Settings  Easy to install Mounting Kit  Easy Access Washable Filter  Digital Time  amp  Temperature Display  24 Hour on off Timer    A  WARNIN    This service information is designed for experienced repair technicians only and is not designed for use by the general public   It does not contain warnings or cautions to advise non technical individuals of potential dangers in attempting to service a product   Products powered by electricity should be serviced or repaired only by experienced professional technicians  Any attempt to service or       repair the product or products dealt with in this service information by anyone else could result in serious injury or death      2009  Qingdao Haier Air Conditioner General corp  Ltd   All right reserved  Unauthorized copying and distribution is a violation of law    Haier Group    Haier ESA408J Table of Contents    Table of Contents    1    1      Product Code Illumination and Series introduction                                   1  SC SREL 2    Safety and uci mec 3    Warning           AUN E 4    Installation and Accessory                                                                              6  e US         UNC UN 2 2                                         14    Abnormity SEENEN 18       System Flow eri c              
14. cessary change      10  NOT connect electrical power to the unit before installation      11  DO NOT use if power cord is worn out  frayed or otherwise damaged   Avoid using if here are cracks or  abrasion damage along the length  plug or connection      12  Be carefull of exposed sharp edges of the cabinet and sharp coils  fins  on the back of the unit that could  cut and cause serious injury      Haiet   Domestic Air Conditioner    Haier ESA408J Installation and Accessory Parts       Window Installation    Window opening measurements                    A  Width  B  Height  MODEL  Dimension       408    A inch  Min 25  63 5cm   A inch  Max 36  91 4cm   B inch  Max 13 2 8   34cm                 Prepare Air Conditioner for Installation    Install Top Channel  1  Place the top channel on the top of the air conditioner  lining up the holes in the top channel with the holes in the top  of the air conditioner     2  Using four   32  screws  attach the top channel to the air conditioner     NOTE  Your model may differ from the one shown                                                AHO                                                                                           A  8 32    screws  B  Top channel    Haiet   Domestic Air Conditioner    Haier ESA408J Installation and Accessory Parts       Install Side Curtains    NOTE Attach curtains to the air conditioner before placing the air conditioner in window     1  Place the tabbed side of the side curtain in the track on the rig
15. ding on your window    6  Do not black airflow inside or outside the air conditioner with blinds drapes protective covers shrubs or  bushes    7 Be careful of sharp edges on the front and rear fins of the unit that could cut and cause serious injury     8 Be careful when lifting the air conditioner to install or remove the unit   Always use two or more people  for this      9 Always unplug the air conditioner before servicing it or moving it      Domestic Air Conditioner    Haier ESA408J Warning and Cautions       4 Warning and Cautions    WARNINGS  Following the safety messages is very important      T These messages can save you from being injured or killed  Warning symbols alert you to be  careful and means Danger   Always follow instructions to be safe and reduce chances of injury  or death   Warning and Danger signs will precde safety messages      Electrical Safety    Grou nding  This room air conditioner must be grounded   Grounding reduces the risk of electric shock by  T providing an escape wire for the electric current   The power cord has a grounding wire with a  grounding plug   Plug it into an outlet that is properly installed and grounded      WARNING  Improper use of the grounding plug can result in a risk of electric shock    Call a qualified electrician if you don t understand the grounding instructions or if you are not sure  A if the air conditioner is properly grounded  If the wall outlet is not grounded   please contact an  electrician to have it replaced
16. eat     Keep the blinds and drapes drawn on all other windows     While cooking use an exhaust fan in the kitchen to remove the excess heat     Always use the correct BTU size air conditioner to cool the room to attain optimum efficiency      Domestic Air Conditioner    Haier ESA408J Installation and Accessory Parts    5  Installation and Accessory Parts  Check the following before you install your air conditioner      1  The units is free of all obstructions inside and outside the room e g  drapes   curtains  Furniture  plants    shrubs  trees  other structures like building   garage etc     The air conditioner must have a clear   unobstructed airflow through the condenser to remove heat      2  The window is strong enough to hold the weight of the air conditioner  Extra brackets or supports may be  needed depending on your windows   Brackets or Supports not provided in all models       3  The windows sill and track are strong enough to hold the weight of the air conditioner      4  The wall is strong enough to hold the unit   Extra brackets or supports may be needed depending on the  wall   Brackets or Supports not provided in all models       5  There is adequate and proper power supply near the air conditioner    As DO NOT use adapter plugs    7  DO NOT use extension cords    A 8  DO NOT cut or remove the ground prong      9  DO NOT modify the plug or the electrical wall outlet in any way   If plug does not fit the electrical outlet have  a certified electrician do the ne
17. hem away from the  keystrokes on PCB        19  Haier    Domestic Air Conditioner    Haier ESA408J System Flow Chart       8  System Flow Chart    Indoor Outdoor  heat exchanger heat exchanger    Compressor          Capacillary tube       Cooling    o          Haier Domestic Air Conditioner    ircuit Diagram          ESA408J    Haier    ircuit Diagram    9 C                      el                            N3AVS                                                                                                                                                                                                                                                                                                                                                              A   A A        A A  Sh A                 ud d   5 ab laSEV CUHEWSCST          op                 vast  saat ra                  oo          ES  L   4       490 YAWIL NO NSAIL MOT dan HOIH                     1000       ALt KOR  osss   ML  14  oss Bai                   AS   JNCV8              XI       i    914 29110070  Se  DENTEN     T    WOSSEWANOD JI SCH             r rra                  TH 5H           TIN OSA    9 n Kos       CON           09    WOO  m               3898                      EET I Wee SH                   ACC E            VF  6080 J01 617  6080 X      LT  GO80 NZ 26 1 F GO8O NZ   TF   6080 2   LY 6080 1 617 080 311 8080 1  e LEM    on     Be TOS CH  H   WW  was d       a a 3 a v a a AS   m    3 3 e 3 3
18. ht hand side of the air conditioner cabinet        A  Tabbed side of side curtain  B  Lock edge side of side curtain    2  Slide the side curtain down the track until the curtain is aligned with the top and bottom of the air conditioner  cabinet                                                                                                                                                                                                                                3  Slide the side curtain frame into the top channel on the top of the air conditioner and the track on the bottom of  the air conditioner                                                                                                                                                                                                                                                           DomesticAir Conditioner    Haier ESA408J Installation and Accessory Parts    4  Slide the side curtain frame as close to the air conditioner as necessary to lock the side curtain to the frame   5  Repeat above steps for the left hand side curtain and frame                                                                                                                                                                                                              Prepare Window for Installation    1  Measure the width of the window opening   2  Mark the center line on the inside windowsill              A  Width of window opening  B  Center 
19. line    Position Air Conditioner   NOTES    m Handle the air conditioner gently    m Be sure your air conditioner does not fall out of the opening during installation or removal    m The place where the power cord exits the air conditioner be no more than 4 ft  122 cm  from a grounded outlet     m Do not block the louvers in the front panel   m Do not block the louvers on the outside of the air conditioner     1 Center the air conditioner in the window  Lower the window sash behind the top channel to hold the cabinet in  place    NOTE  Your model may differ from the one shown     Haier Domestic Air Conditioner    Haier ESA408J Installation and Accessory Parts                                          JE                                                                            A  Side curtain against window channel  B  Window sash behind top channel  C  Bottom channel in behind windowsill    2  Loosen the screw on the right hand side of the air conditioner cabinet near the bottom     4    SS 2   z P               3  Slide the side bracket over the screw   4  Tighten the screw  The side bracket should be resting on the windowsill                                                                                                                                                                                                                                      E                      _ ee  Haier Domestic Air Conditioner    Haier ESA408J Installation and Accessory Parts    5  Use  8   
20. tan     AcHX edcH   ASCInOO01   anto S anto 91 In0LF  ES oa         P   ta  ZootNI P   va    lasnd T L    E        Ei 12 CO va  0   1    8 0    1 8 IND    Dl  ZINO DE 9     Log                         T  OSEAPIS  ASLTANI O   ome mE          22    Domestic Air Conditioner    Haier    Haier ESA408J Wiring diagram    10  Wiring diagram          WIRING DIAGRAM                                                                                                                                                                                                                                                                                                                                                                                           Haier    COMPRESSOR  FAN M 5  TRANSFORMER MOTOR          p VR  M GR HEAT  2  PROTECTOR   un BR           PR    CAPACITOR  CAPACITOR  B BUR R              NLMH  CN       E    116  5 Lj     tr   COMPRESSOR  2 CN2  O J           Lj       a  pa  Ge        2      B NO RIBBED              atio                      W RIBBED   GR  GRAY     SR ORAN POWER SUPPLY         BL  BLUE  R  RED  B  BLACK  W  WHITE  Y G  YELLOW GREEN  NOTE   THE DOTTED PART MAY NOT BE USED     Domestic Air Conditioner    Haier ESA408J    The end    Sincere Forever    Haier Group    Haier Industrial Park  No 1  Haier Road  266101  Qingdao  China_    E mail  hractech haier com  Tel   86 532 87636960    Http   www haier com    Haier    Edited by   Guan Li  li Hao    Signed by   Yao Hong Fang
21. to increase or  decrease the time     3  After 5 seconds  the display on the air conditioner control panel will show the current room temperature     EE EE  Haier Domestic Air Conditioner    Haief ESA408J Abnormity Diagnose    7  Abnormity Diagnose    1 Sensor Diagnose     2 seconds after the sensors open circuit or short circuit   the unit will turn off automatically and the LED wil  show EO until the sensors resume      Firstly check whether Terminal CN2 on Pull out the terminals on the indoor       NO  the indoor mainboard contact well or mainboard and reinsert them   not   YES  Pull the sensor out of the mainboard  1  Measure the value of resistance  between its two jumpers  2  Measure the temperature at the YES Replace with new sensor   room temperature sensing head   Check the specifications of the sensor  to decide whether the sensor is  damaged or not   YES    The Indoor PCB is broken     Replace with new indoor PCB       o B  Haier Domestic Air Conditioner    Haier ESA408J Abnormity Diagnose    2 Keystroke circuit error diagnose      When power on for the first time   the PCB will check the keystroke circuit   if the sampling value is different    with the theory value   the LED will show       whice means failed keystroke circuit The keyboard is locker and so  invalid   but the remote control is working normally      Check whether the keystroke can   t    PCB is broken  replace a new PCB   get up with pressure     Repair the keystrokes on electrical    box to keep t
    