Home

TITAN brochure international.indd

image

Contents

1. 99 9 ability to correctly identity babies with hearing problems and a specificity above 96 ability to correctly exclude babies with normal hearing Easy to use Following patient preparation electrode imped ance information is automatically displayed Simply press start and on completion of the test a simple pass reter result is displayed on screen requiring minimal tester training Transducer options Choose from three transducers probe insert earphones headphones that are automatically detected when connected to the PreAmplitier With in built transducer calibration transducers can easily be swapped in and out CE Chirp amp Bayesian weighting The default stimulus for automated ABR Is the patent pending CE Chirp stimulus Unlike the traditional click the CE Chirp provides a better neural stimulation allowing faster detection of a response and in turn helps reduce the test time by up to 50 Optionally the click stimuli or the Hi Lo frequency specific CE Chirp stimuli can be selected In a nutshell Bayesian weighting improves the recording conditions for patients that have fluctu ating EEG noise moving patients is a stimulus family designed to compensate for the cochlear travel time The result is a synchronized neural firing of the nerve fibers creating up to twice the response amplitude compared to standard click Design your own reports Although electronic communication plays an increasing ro
2. Read more here www interacoustics com com Titan Specifications DPOAE440 software Stimulus Frequency range Frequency step Level Level Step Transducer Recording Analysis time A D Resolution Artifact rejection system Stimulus tolerance SNR criteria Probe check window DP response window Display General display gain Display Probe specifications Titan IOW probe Other Test types Test Pressure Included parts DPOAE440 module Optional parts DPOAE440 module 500 to 10000 Hz 25 HZ 30 to 80 dB SPL 75 dB SPL for 6kHz and 65 aB SPL for 8kHz to 10kHz 1 dB IOW Probe auto detection auto calibrated Minimum 2 seconds to unlimited time 24 bit 5 38 Hz resolution 30 to 30 dB SPL or off Adjustable between 1 and 10 dB Adjustable between 3 and 25 dB 256 points frequency response of the ear canal due to a click stimulus 4096 points frequency response Applicable during testing Stimulus level and type Bar and Graph view IMP DPOAE and ABRIS capable Replaceable probe tip Screener Clinical DP Gram 500 6000Hz max 500 6 test points 10000Hz DP I O n a X Add test measurement point n a X Enable Pass Refer X X Ambient pressure Screener Clinical Titan handheld unit with basic probe X X Cradle X X ASA30M Power supply with converter X X Clinical probe extension X X BET55 Ear tips and box Xx x DG LiBat 001 back up battery x x 4 cavities 0 2 05 2 and 5
3. Fast multi purpose and portable Interacoustics leading diagnostic solutions ABRIS OAE Impedance The Titan concept Titan Impedance DPOAE Automated ABR choose between one two or all modules Titan DPOAE Titan automated ABR ABRIS Titan is a modular platform offering impedance automated ABR and DPOAE testing This flexible combination instrument allows you to create the perfect screening instrument or can be configured to perform advanced clinical testing With so many combination options the Titan allows you to meet the needs of your clinic today and with the option to upgrade to other modules later also meets the needs of your clinic in the future Easy handling Titan s slim neck and lightweight form allow for easy use in handheld mode Together with its contemporary design Titan suggests a profes sional appearance in the clinic The high resolu tion color display provides an excellent overview of test progress and results The various available probe and transducer configurations enable a strong focus on patient centered testing toward the aim of achieving consistently reliable measurements all with little need for user attention to the underlying technol ogy Test status is viewable by LEDs on the probe and a shoulder mounted unit allows easy choice of ear and test start stop Additionally calibration values are stored in the probe and ID transducers allowing easy chang
4. ass or Refer giving a simple and easy to un derstand test result For clinical testing the manual mode enables the user to add extra test frequencies for a more detailed patient examination DP Input Output For advanced clinical testing or research purposes the Titan also offers DP Input Output testing across all frequencies User definable stop criteria can also be applied as in the DP Gram test DPOAE440 DP Gram a PASS Bar view DPOAE highlights e Noah amp Hilrack compatability e Handheld or PC Controlled use e Customisable protocols e 500Hz 10kHz 1kHz 6kHz Screener e Customisable PASS REFER criteria e DP Gram or DP I O tests available e Bar or Graph View Interacoustics leading diagnostic solutions ABRIS440 module ABRIS440 Automated ABR The ABRIS440 module for Titan has been de signed with the latest technologies available for fast and easy automated ABR testing for infants The ABRIS440 screening module incorporates the CE Chirp stimulus and Bayesian weighting typi cally reducing test time by up to 50 compared to traditional click stimuli With an easy to understand display PC or Handheld device HiTrack compatibility and user customizable protocols Titan with ABRIS440 is the perfect instrument for any newborn hearing screening program ABRIS440 PASS Reliable screening The ABRIS440 default protocol provides a reliable automated ABR test with a sensitivity of
5. cc X X Titan PC suite with DPOAE440 X X OtoAccess database X X USB cable USB adaptor X Xx Operation manual X X Multilingual CE manual X X TCB Carrying Bag X Xx Short probe extension optional optional Thermal printer AB1310 AB1310 Bluetooth optional optional Specifications Specifications IMP440 software Impedance Measuring System Probe tone Air pressure Compliance Indicators Memory Test types Reflex Functions Signal sources Outputs Test types Frequency 226 Hz and optionally 678 Hz 800 Hz and 1000 Hz Level 69 dB HL with AGC assuring constant level at different ear canal volumes Control Automatic Indicator Measured value is displayed on the graphical display Range 600 to 300 daPa Pressure limitation 750 daPa and 550 daPa Pressure change rate Very slow Slow Medium Fast Automatic with slow speed at compliance peak Selectable in the set up Range 0 1 to 8 0 ml at 226 Hz probe tone Ear volume 0 1 to 8 0 ml and 0 1 to 15 mmho at 678 800 and 1000 Hz probe tone Graphical display Compliance is indicated as ml and pressure as daPa In PC controlled mode admittance susceptance and conductance can be printed Stimulus level is indicated as dB Hearing Level Tympanometry 1 curve per ear per tympanometry test 3 curves per ear per Eustachian tube function test And theoretically an infinite number of tests per protocol Screening Diagnostic Clinical e Tympanom
6. coustics A S meets the requirements of Annex ll of the Medical Device Directive 93 42 EEC Approval of the quality system is made by TUV identification no 0123 Safety IEC 60601 1 Internally powered Type B BF applied parts EMC IEC 60601 1 2 Impedance IEC 60645 5 ANSI 3 39 Type 1 Test signal IEC 60645 1 ANSI S3 6 IEC 60645 3 OAE IEC 60645 6 2009 Type 2 Otoacoustic emissions ABR IEC 60645 7 2009 Type 2 Titan IOW probe IMP DPOAE and ABRIS capable Replaceable probe tip Test Pressure Ambient pressure USB Input output for computer communication Titan can be fully operated from a PC The measurements can then be followed on the PC screen Data can be sent to and saved on the PC and stored in the Interacoustics database OtoAccess See separate section in Service Manual for programming details Memory Theoretically an infinite amount of test results can be stored on the PC The Titan hand held unit is delivered with a 1 Gb memory card enough for storing more than a quarter of a million tests Type Thermal Bluetooth printer with recording paper in rolls Print on command through Bluetooth communication and through serial RS 232 Paper width 57 5 0 5 mm on thermal printer Printing time Printing time depends on the size of the used protocol For 2 tympanograms and 8 reflexes the thermal printer uses approximately 6 s 6x6x28cm 2 4x2 4x1 1inch 360g 0 8lbs 1209 102 083 26 mm 64g 65 35 1E mm
7. e middle ear system e g due to heart beat pulsation in a glomus tumor Acoustic reflexes evoked by a cochlear implant can also be easily measured Extension cord with shoulder unit and probe indicator LED At times when the clinician cannot step away trom the patient the extension cord with the shoulder box enables full operational control ear choice start stop and the LED indicates if the probe is sealed correctly or blocked Clinical impedance highlights e Automatic and manual testing e High frequency probe tones 678 800 and 1000Hz e psi and contra acoustic reflexes e 3 ETF tests Intact perforated and patulous e Reflex decay e Reflex latency DPOAE440 module The DPOAE module DPOAE440 is a module for the Titan platform allowing you to test Distortion Product OAEs and is available in either a screening or clinical version The DPOAE440 module will meet the needs of any newborn hearing screening program as well as busy ENT or audiologic clinics DP Gram DPOAE frequencies can be tested between 500Hz 10kHz with user definable stop criteria includ ing test time or point time Signal to Noise Ratio SNR minimum DP level residual noise and DP reliability Titan ensures a precise stimulus inten sity using advanced real ear detection methods and can be configured to reject measurements in noisy environments providing more accurate results For screening purposes protocols can be labelled as P
8. es of transducer or probe contiguration _ Titan carrying case The light indication in the probe is guide for probe status and ear D ijp E F A fall Right ear Left ear Blocked leaking Interacoustics leading diagnostic solutions IMP440 module The impedance module The impedance module IMP440 is available in a screening diagnostic or clinical version allowing you to configure the Titan for the tests you need The test battery features standard tympanometry ipsi and contralateral acoustic reflexes reflex de cay and reflex latency as well as three Eustachian tube function tests Together with optional high frequency probe tones 678 800 and 1000 Hz IMP440 is designed to meet and perform the most demanding of clinical testing requirements Each version comes with preloaded factory proto cols as well as the option for creating one s own test protocols and sequences Tympanometry Interacoustics utilizes two beneficial advanced technologies to acquire tympanograms The first is an endless airflow technology which improves the instrument s ability to obtain a tympanogram on difficult to test patients or when a slight leak is present The second is an intelligent pump control system with an adaptive speed control around the tympanic peak This feature combined with high resolution recording of both compliance and pressure level provides the fastest and most reproducible tympan
9. etry Automatic flexible start and x Xx X stop pressure e Tympanometry Manual X e ETF1 Non perforated eardrum Williams n a X X test e ETF2 Perforated eardrum Toynbee test n a n a X e ETF3 Patulous Eustachian tube Sensitive n a n a X baseline tympanometry for 10 up to 60 seconds Tone Contra Reflex 250 500 1000 2000 3000 4000 6000 8000 Hz Tone Ipsi Reflex 500 1000 2000 3000 4000 Hz NB noise Contra Reflex 250 500 1000 2000 3000 4000 6000 8000 Hz NB noise Ipsi Reflex 1000 2000 3000 4000 Hz Noise Contra Reflex Wide Band High Pass Low Pass Noise Ipsi Reflex Wide Band High Pass Low Pass Contra Earphone TDH39 earphone DD45 earphone EARtone 3A and or CIR55 insert for Reflex measurements losi Earphone Probe earphone incorporated in the probe system for Reflex Screening Diagnostic Clinical e Automated Reflex with single intensities or reflex growth Ipsilateral X X X Contralateral n a X X e Manual control of all reflex functions X X X e Reflex decay automatic 10 dB above thresh n a x x old or manually controlled with stimulus duration of 10 up to 30s e Reflex latency automatic 10 dB above n a n a X threshold or manually controlled first 300 ms from stimulus start Read more here www interacoustics com com Titan Included parts IMP440 module Optional parts IMP440 module Screening Diagnostic Clinical Titan handheld unit with basic
10. ets the highest possible engineering standards and we provide design expertise that can only come from close contact with clinical practice Solutions on every scale Designing equipment for every size of clinic in so many countries puts us in the unique position of being able to offer solutions that fit your requirements exactly Audiometry tympanometry electrophysiology hearing aid testing balance investigation are all within our scope and can be integrated to suit your needs Designed for diagnostics efficiency We design equipment to make testing and interpretation easier This means better interfaces well designed screen layouts printed reports and interaction over networks with databases and electronic records systems In most cases you can configure the settings and layout yourself Support worldwide The Interacoustics name Is not only your guarantee of quality and functionality but also tor support We operate in over 100 countries worldwide through a well coordinated network of distributors and service centres to ensure that you receive total support and service Sales and service in your area Related products Eclipse EP25 Advanced ABR EP15 Clinical ABR Interacoustics ASSR ABRIS Newborn Screening VEMP TEOAE25 Sreening and Clinical TEOAE DPOAE20 Screening and Clinical DPOAE OtoRead Handheld OAE Middle ear analyzers AT235 Middle Ear Analyzer AT235h Middle Ear Analyzer MT10 Handheld Ty
11. le in audiology the printed report is still important The Titan software suite includes an embedded print wizard a very flexible tool enabling the realization of individual reporting needs as well as adherence to internal report ing and archiving structures to streamline clinic workflow Interacoustics Sahar G8 al Preis 9 dla The print wizard can merge data from all three ee eee modules and other Interacoustic Suites for full patient reporting Once completed test data Is automatically routed to predetined templates eliminating redundancy and the labor intensive tasks routinely involved in getting all information presented on a single page Reports can either be printed or saved as PDF s for insertion into EMR systems HSEEBBEBAPRBHeBHUBSe Ss be rts Gee ire 1 rel Peist 24 al DF Gram Right DP Gram Lett Biu i bee es Ae Mikbthg AniTL HE Pbi j blii r Sin eet eet The optional printer wot Benth CERZH Atco Merge and configure input from different sources in the Print Wizard Interacoustics leading diagnostic solutions Specifications Specifications Titan Hardware Medical CE mark Standards Probe specifications PC control Thermal printer Optional Titan Dimensions Titan Weight ABR OAE IMP shoulderbox Weight ABR OAE IMP shoulderbox Dimensions OAE IMP shoulderbox Weight OAE IMP shoulderbox Dimensions The CE mark indicates that Intera
12. ls 1 Level 30 dB nHL 35 dB nHL 40 dB nHL Analysis time 1 10 min or Residual noise 5 80 nV Bandwidth 22 05 kHz A D resolution 24 bit Weighting Bayesian weighting Artifact reject system Rejection level Peak Min RMS Max RMS Clipping Saturation Display Stimulus level and type bar and graph view Click 99 9 CE Chirp 99 9 Titan handheld unit with basic probe Cradle ASA30M Power supply with converter PreAmplifier w clothing clip amp neckstrap Short extension cable ETSE tab surface electrode cables Sanibel tab surface electrodes 36 pcs SPG15 preparation gel Alcohol pads Gauze swabs USB cable USB adaptor BET55 Ear tips and box DG LiBat 001 back up battery A cavities 0 2 0 5 2 and 5cc Titan PC suite with ABRIS440 OtoAccess database Operation manual amp multilingual CE manual TCB Carrying Bag Earlone ABR earphones Thermal printer AB1310 AB1310 Bluetooth TDH39 Stereo ID headset DD45 stereo ID headset HiLo CE Chirp 99 9 Interacoustics leading diagnostic solutions Screener X XK XK KK KK KK KK KKK KK X optional optional optional optional Interacoustics the wise choice With over 40 years of experience Interacoustics is dedicated to supplying its custom ers with the best possible solutions for their audiologic needs This is accomplished by maintaining a continuous dialogue with healthcare professionals working in all sectors of audiology Our equipment me
13. mpanometer Audiometry and Middle Ear Analyzer in one AA222 Audio Traveller The Eclipse with ASSR 83014503 3 04 2011 Read more here www interacoustics com com Titan Interacoustics Interacoustics A S Pinole 5 37 S155 5 Fee 5 Ge S22 E mail info interacoustics com DK 5610 Assens Denmark Web www interacoustics com leading diagnostic solutions
14. ometry measures available Acoustic reflex test Acoustic reflexes are measured ipsi and contralat erally through a headphone or insert phone Protocols can be set up for quick screenings at a single intensity or for fast reflex threshold searches Manual testing at individual frequen cies and intensities is also available The optional Automatic Gain Control AGC also provides accurate and safe intensity reflex stimulation for small ear canal volumes Reflex Decay Acoustic reflex decay testing is available with ipsi lateral as well as contralateral stimulation using a single headphone TDH39 DD45 the CIR55 or the optional EarTone3A Reflex latency The reflex latency test focuses on the first few hundred milliseconds of the acoustic reflex It allows a detailed investigation of the onset of the reflex as a function of stimulus type and intensity As in decay testing Titan will automatically search for the reflex threshold if that is not yet known and perform the ipsi or contralateral stimulus 10 dB above the threshold level Three Eustachian tube function tests Titan performs three different Eustachian Tube Function tests for different conditions of the eardrum and Eustachian tube ETF for intact ear drum ETF for perforated eardrum and ETF for a patulous Eustachian tube In addition to record ing information about Eustachian tube function the third ETF test is suitable for measuring spon taneous changes in th
15. probe X x X Cradle optional X X ASA30M Power supply with converter X Xx Xx Clinical probe extension optional x X CIR55 contra insert headset n a X X BET55 Ear tips and box X X X DG LiBat 001 back up battery X X X A cavities 0 2 0 5 2 and 5cc X X X Titan PC suite with IMP440 xX X xX OtoAccess database optional X X Operation manual amp Multilingual CE manual X X x TCB Carrying Bag X X X Short probe extension optional optional optional Thermal printer AB1310 AB1310 Bluetooth optional optional optional DD45C contra cup headset n a optional optional EARtone 3A insert headset for contra n a optional optional Specifications ABRIS440 software ABR Infant Screening One Channel EPA3 Cable Collector 3 electrodes 50 cm Gain 64 dB EPA Preamplifier Electrical Impedance measurement Stimulus Algorithmic Sensitivity Included parts ABRIS440 module Optional parts ABRIS440 module Frequency response 0 5 5000 Hz Noise lt 25nV VHz CMR Ratio gt 90 dB Max input offset voltage 2 5 V Input impedance 10 M 170 pF Power from main unit Isolated power supply Measurement frequency 33 Hz Waveform Rectangular Measurement current 11 25uA Range 0 5 kQ 25 KQ 10 Click range 177 11313 Hz CE Chirp range 177 11313 Hz HiLo CE Chirp range Lo 177 1414 Hz Hi 1414 11313 Hz Stimulus rate 90 Hz Transducers Earlone ABR insert phone TDH 39 DD45 head phone IOW probe Channe