1. TOV I BOHz re il i 8 D e 224 6 cial m m AH el FO 4 Te reo red white black Fuse 20 A H T Transformer Overheat thermostat Fuel solenoid valve Photocell Capacitor Fan motor Control lamp white BRAHMA TGRD91 CSA 1184 RV TA AP RF PA FUA RE FU black black Main switch Room thermostat plug Flame control box Heated fuel filter optional Air pressure switch Fuse 6 3 RELAY FUSE 20 A Air pressure switch PA and overheating thermostat LI1 are connected in serie to fuel valve EV1 Therefore in case LI1 opens the fuel valve EV1 is switched off and the flame control unit goes in lock out in the flame failure mode 21 GE 600 LIT EV1 FO CO MV ST NOTE black el Fuse 20 A H T Transformer Overheat thermostat Fuel solenoid valve Photocell Capacitor Fan motor Control lamp RV TA AP RF PA FUA RE FU black white Main switch Room thermostat plug Flame control box Heated fuel filter optional Air pressure switch Fuse 6 3 RELAY FUSE 20A Air pressure switch PA and overheating thermostat Ll1 are connected in serie to fuel valve EV1 Therefore in case PA and LI1 opens the fuel valve EV1 is switched off and the flame control unit goes in lock out in the flame failure mode 22 7 TECHNIC
2. 1 Check main supply is switched on 2 Check connection of extension power cord 3 Check integrity of main fuse b Motor does not run and reset lamp is red i Flame control box in locking condition for a previous problem 1 Reset and repeat the starting cycle once time only 2 Refer to following if any new problem occurs c Motor does not run and reset lamp light up after 30 secs i Air flow failure 1 Check fan motor connections 2 Check fan is tightened on fan motor axle 3 Check fan is free to rotate if not make service on fuel pump 4 Check and eventually replace fan motor and or motor capacitor d Motor does not run and reset lamp is off unit is in stand by i Room thermostat main switch failure 1 Check room thermostat 2 Check room thermostat connections 3 Check main switch on heater control board li Photocell failure short circuit 1 Replace photocell ii Flame control box failure 1 Check fuse integrity on flame control box 2 Check wiring connection and eventually replace flame control box iv Voltage lower than 70 V or higher than 150 V 1 Check supply voltage is correspondant to rating plate 2 Unit will automatically restart when voltage becomes higher than 80 V or lower than 140 V B HEATER STARTS BUT DOES NOT COMPLETE STARTING CYCLE a Motor runs continuously there are no flame and reset lamp is off i Extraneous light or flame during pre purge cycle 1 Check positioning of photocell 2 Make service of combustion
3. placed in the right position viii Tighten screw a 10 b To clean replace the standard type fuel filter carry out the following procedure i vi vii Loosen the casing a that secures to the housing Using a suitable container collect the fuel when removing from the fuel filter assembly Remove fuel cell c and o ring b and wash with clean diesel oil If necessary replace the fuel cell c Inspect the o ring replace it if it is cracked damaged or deformed Reassemble the filter assembly checking the o ring is placed in the right position Tighten casing a by hand checking the o ring is pressed 3 FUEL PUMP ASSEMBLY a Toreplace fuel pump carry out the following procedure T JE jy ny 4 Remove the top cover access panel b by removing six screws Loosen three screws e on the fuel pump casing be sure not to remove the screws Remove fuel pump from electric motor and keep plastin coupling for next reassembling Disconnect wires lead to fuel solenoid valve g Reassemble new fuel pump on electric motor being sure that plastic coupling is aligned Tighten three screws e Reinstall the top cover 11 b To set fuel pressure on fuel pump carry out the following procedure 21 R5 071N2335 i Remove the top cover access panel b by removing six screws ii Loosen cap a on front of fuel pump and connect a fuel pressure meter iii Disconnect wires lead to fuel solenoid valve to
4. AL SPECIFICATION scam atm cewe C NENNEN a NN ELEC e e fe ef CI o Electric consumption rs mo e Static pressure Flue diameter Adjustment of combustion air flap 23
5. DIESEL SPACE HEATER SERVICE MANUAL INDEX CONTROLS AND COMPONENTS FLAME CONTROL CYCLES MAINTENANCE SCHEDULE REPAIR PROCEDURES 1 FAN MOTOR ASSEMBLY FUEL FILTER ASSEMBLY FUEL PUMP ASSEMBLY ELECTRIC PANEL ASSEMBLY AIR PRESSURE SWITCH COMBUSTION HEAD ASSEMBLY 7 COMBUSTION CHAMBER 8 COMBUSTION TEST TROUBLESHOOTING GUIDE WIRING DIAGRAMS TECHNICAL SHEETS e AY EC 200 EC 300 GE 360 GE 400 GE 600 L S 102 00 BM A WARNING The operations described in this booklet must be carried out by qualified and instructed personnel only Incorrect maintenance may result in improper operation and serious injury 1 CONTROLS AND COMPONENTS INDIRECT HEATER WITH STACK EC 200 EC 300 1 2 22 a 3 21 5 4 6 7 DIRECT HEATER WITHOUT STACK GE 360 GE 400 600 1 2 3 21 5 4 6 7 a i i E jl SS 18 18 20 919 12 CONTROL PANEL 13 14 15 17 16 COMBUSTION CHAMBER BURNER ASSEMBLY NOZZLE FUEL VALVE DIESEL PUMP MOTOR FAN FUEL FILTER FUEL CIRCUIT 10 FUEL TANK 11 FUEL TANK PLUG 12 DRAIN PLUG 13 RESET BUTTON LAMP OF CONTROL FLAME 14 MAIN SWITCH 15 ROOM THERMOSTAT PLUG 16 CONTROL LAMP 17 POWER CORD 18 OVERHEAT THERMOSTAT 19 AIR PRESSURE SWITCH GAUGE LOW PRESSURE SIDE 20 AIR PRESSURE SWITCH GAUGE HIGH PRESSURE SIDE 21 FLAME DETECTOR PHOTOCELL 22 STACK CONTROL SYSTEM The heater has all operational controls located in
6. MBUSTION CHAMBER ASSEMBLY a Toclean combustion chamber assembly carry out the following procedure i Remove the top cover access panel b by removing six screws Loosen and remove three nuts iii Remove the burner head tube assembly c iv Check and clean inside combustion chamber with a cloth removing liquid fuel residual v Reassemble burner head tube assembly c vi Reassemble top cover b 16 8 COMBUSTION TEST HEATER WITH FLUE ONLY a To check combustion smoke index with Shell Bacharach method carry out the following procedure i Use a standard Bacharach pump ii Insert a test strip b into the pump slot iii Insert the pump end into the flue connection c or flue extension iv Start the heater and wait five minutes until it operates in standard conditions v Pump in exhaust gases for 10 times taking care to carry out all movements slowly and using the complete piston stroke vi Extract the paper strip check the colour and compare it with the reference scale d to assign a smoke number 1 Oil fired heaters are tested and set by factory to give a smoke number equal to 0 zero of the Shell Bacharach scale 2 A smoke number greater than 1 indicates bad combustion Refer to following troubleshooting guide to find the causes of the problem and to correct them 17 5 TROUBLESHOOTING GUIDE A HEATERS DOES NOT START a Main control lamp is off i Missing connection to main supply line
7. a watertight control panel mounted on the lateral side of the unit The control panel consists of a 3 position switch for heating function normal operation stop or thermostat operation plug to connect a remote room thermostat power cord high voltage transformer that generates a spark to ignite the flame control flame box to handle starting running cycle see paragraph 2 The control flame box is equipped with a reset The control system utilizes e a safety shut off switch that is a overheat thermostat shutting down the unit if the temperature of combustion chamber and outlet air exceed the maximum allowed level e pressure switch that stops the unit if the air flow is not sufficient for combustion a flame detector that is a photocell monitoring constantly the flame presence and its integrity a pair of ignition rods to create the ignition spark FUEL SYSTEM The fuel system consists of e fuel tank that is steel corrosion proof The fuel tank hase a drain plug located underneath it to allow discharge of residual fuel before cleaning e fuel filter e fuel pump A screw fitted on the fuel pump allows the adjustment of fuel pressure setting e fuel ON OFF solenoid valve o during normal operation the valve is open and the pressurized fuel flows to the nozzle where it is atomized mixed with primary combustion air and ignited by the electrode spark o during abnormal operation see paragraph 2 the flame control unit closes the fuel solen
8. and the starting cycle to be performed 4 2 3 FLAME FAILURE DURING STARTING CYCLE Room thermostat Burner Fan ignition Transformer Fuel Valve Photocall Reset Lamp If during the safety time TS the photocell monitors a flame failure signal to photocell become lower than minimum at the end of safety time the unit goes in lock out condititon e burner fan ignition transformer and fuel valve are de energized e alarm lamp on reset button becomes red Unit can re start only if pressing the reset button 2 4 EXTRANEOUS LIGHT OR FLAME DURING PRE PURGE TIME TP Room thermostat Burner Fan ignition Transformer Fuel Valve Photocell Reset Lamp TP 20 4 If during the pre purge time the photocell monitors any residual flame then the unit goes in stand by condition e burner fan goes on to purging combustion chamber e fuel valve and ignition transformer are de energized e reset lamp is off 2 5 FLAME FAILURE DURING RUNNING STATUS ONE TRIAL RECYCLING Room thermostat Burner Fan ignition Transformer Fuel Valve Photocell me Reset Lamp TP 20 5 TS 5a B a In case of flame failure in running status the flame control unit make one trial restarting the unit If the reason of flame failure is confirmed then the unit stops in lock out mode and the reset lamp becomes red 2 6 RESET LAMP COLOR A WARNING The reset button may have different colours light off unit is in stand by stat
9. avoid fuel spray inside combustion chamber A WARNING The following operation shall be done with top cover and possible access to rotating fan Fan rotating area is covered by fan support even if accessible Take measure to avoid touching any rotating parts while setting fuel pressure iv Start the heater and check the fuel pressure be the value listed in the final technical sheet v Correct the pressure by screwing to increase pressure or unscrewing to decrease pressure screw b vi Remove fuel pressure meter and tighten cap a vii Connect wires to solenoid fuel valve viii Reinstall the top cover 4 ELECTRIC PANEL ASSEMBLY To check electric control board carry out the following procedure i Remove two screws a on front side of heater ii Remove top cover b of electric board 12 Check that all connections are complete and tight iv Reassemble top cover b and fix electric board to the heater 5 AIR PRESSURE SWITCH To check replace air pressure switch carry out the following procedure i Remove four screws a on side of heater ii Pull air pressure switch assembly out of the base iii Check silicon tube are not pinched and tightened to connectors iv Check there is no debris inside silicon tube v Reassemble pressure switch assembly and tighten screws a 6 COMBUSTION HEAD ASSEMBLY a clean combustion head assembly carry out the following procedure i Remove the top cover a
10. ccess panel b by removing six screws WA li Loosen screw and remove fast on connector of yellow green wire c 13 iii Turn counterclockwise burner support d and pull it out of burner tube e iv Check Clean diffuser ring f 1 be sure any debris or soot is eliminated every wing and opening on front surface of ring 2 if necessary loosen screw f and remove it to wash using clean diesel 3 check for any damage or bended part if any replace it v Check clean ignition electrodes g 1 Clean and remove any debris or soot on sharp ends of electrodes 2 If necessary remove both electrodes and replace 3 Check alignment as by following image electrodes shall be centered and symmetric 4 Check electrode connectors h be tightened and clean 14 vi Check replace fuel nozzle 1 Refer to technical data sheet for specific indication of nozzle type 2 Remove electrodes g 3 Remove diffuser ring f 4 Loosen fuel nozzle and place a new one 5 Reassemble diffuser ring and electrodes taking care of each correct positioning as by previous instructions vil Check clean photocell 1 Remove photocell i and check it is clean 2 Check photocell support be clean and clean hole m viii Check adjust air openings 1 Loosen nut n 2 Adjust lever p until the requested opening is obtained check final tech sheet 15 ix Reassemble combustion head x Reassemble top cover 7 CO
11. ency Purging time TP 20 seconds fan motor and ignition transformer are simultaneously switched on while the fuel valve remains closed to eliminate any fuel or unburnt residual During the purging stage the flame signal is constantly monitored and any kind of failure leading to combustion prevents the burner ignition In case of heating request opening room thermostat opening the control unit goes to stand by position The device remains in this status till closing of the room thermostat Safety time 5 seconds at the end of the purging time TP the fuel valve is switched on and opens the fuel to the nozzle In case of flame detection failure by the end of the TS safety time the control unit goes to lockout and the fan motor the ignition transformer and the fuel valve are de energized while the lockout signal is enabled Otherwise at the end of the TS safety time the control unit disables the ignition transformer and goes to running position At the end of the TS safety time the control unit keeps the ignition transformer operating for about 30 s 2 2 SHUT OFF CYCLE Room thermostat mm Burner Fan ignition Transformer Fuel Valve Photocell Reset Lamp When the heating request normal operation or thermostat operation opens fuel valve and ignition transformer are switched off and the flame lights off burner fan operates a 90 s post purge ventilation Restoring the heating request causes the post purge to be interrupted
12. head and combustion chamber removing any residual fuel inside 3 Check any sunlight or external light can reach the photocell b Heater stops in lock out and reset lamp is on red light i Flame failure during starting cycle because of incorrect ignition 1 Check connection of ignition electrode 2 Check clean and adjust positioning of ignition electrode 3 Check ignition transformer and eventually replace 4 Check main connections to ignition transformer ii Flame failure during starting cycle because of missing incorrect flame 1 Check fuel tank is not empty 2 Check fuel type be correct and clean 3 Check and clean fuel filter cartridge 4 Check all connections of fuel line from tank to fuel pump untightened connections can cause suction of air to fuel pump 5 Check fuel line from to the fuel tank and to the nozzle are not obstructed or damaged and eventually replace 6 Check and clean fuel nozzle eventually replace it 7 Check and clean combustion head nozzle nozzle support and diffuser disc 8 Check and eventually replace solenoid valve on fuel pump 9 Check adjustment of fuel pump pressure 10 Check adjustment of combustion air 18 C HEATER STARTS BUT IT DOES NOT RUN REGULARLY a Heater stops in lock out and reset lamp is on red light i Flame failure because of missing fuel 1 Check fuel tank not be empty 2 Check fuel type be correct clean without water 3 Check and clean fuel filter cartridge 4 Check all connec
13. keep plastic coupling for next reassembling vil Loosen and remove eight screws f that fix the motor on the motor flange viii Open main electric board on side front of the heater ix Trace the electric motor power cords and disconnect the three wires white black green from control panel X Position a new motor on the motor flange and reassemble eight screws f to fix it xi Check alignment of the motor to the heater axis and tighten eight screws f on motor flange xii Reassemble fuel pump on electric motor being sure that plastic coupling is aligned xiii Tighten three screws 6 xiv Position fan blade on the motor shaft being sure there is no interference with any parts when rotating xv Tighten screw d and check free rotation of the fan blades xvi Reinstall the fan grille and the top cover 2 FUEL FILTER ASSEMBLY a Toclean replace the pre heated type fuel filter carry out the following procedure i Remove the screw a that secures the cover to the housing and remove o ring b li Using a suitable container collect the fuel when removing from the fuel filter assembly iii Remove the fuel cell c and wash it with clean diesel oil iv If necessary replace the fuel cell c v If necessary to replace the heating element loosen the nut d and remove the electric resistance vi Inspect the o ring replace it if it is cracked damaged or deformed vil Reassemble the filter assembly checking the o ring is
14. les in the suction line to fuel pump 1 Check oilf filter casing is tightened 2 Check check all connection on fuel line to fuel pump are tightened 3 Check fuel line are not obstructed 4 Check fuel tank level D HEATER RUNS WITH BAD COMBUSTION AND EVENTUALLY WITH WHITE OR BLACK SMOKES a Heater runs with white smokes i Fuel air mixing on combustion head is incorrect excess air or few fuel 1 Check adjustment of fuel pump pressure 2 Check adjustment of combustion air b Heater runs with black smokes i Fuel air mixing on combustion head is incorrect few air or excess fuel 1 Check adjustment of fuel pump pressure 2 Check adjustment of combustion air c Heater runs with noisy irregular combustion with without smokes i Combustion is incorrect 1 Check and clean fuel nozzle eventually replace it 2 Check and clean combustion head nozzle nozzle support and diffuser disc 3 Check exhaust is not obstructed 4 Check combustion chamber is not clogged by soot and eventually wash and clean it 19 E WHEN SWITCHING OFF HEATER DOES NOT STOP a Heater still runs with flame Room thermostat main switch failure 1 Check room thermostat and room thermostat connections 2 Check main switch on heater control board li Fuel flow to nozzle is not interrupted 1 Check fuel solenoid valve is closing fuel line to nozzle 20 6 WIRING DIAGRAM EC 200 EC 300 GE 360 GE 400 FU LI EV1 FO CO MV ST NOTE RF
15. maintenance operation the heater must be disconnected from power supply Refer to instruction manual to fully stop the heater Therefore e Stop the machine as instructed e Turn off the disconnecting switch on the main electric switchboard e Wait until the heater has cooled Never service heater while it is plugged in operating or hot Severe burns or electrical shock can occur 1 FAN MOTOR ASSEMBLY Nye Toclean the fan blades and motor carry out the following procedure i Remove the air inlet grille a by removing four screws that secure it to the machine ii Remove the top cover access panel b by removing four screws iii Inspect and if necessary clean the motor using compressed air being carefully not to direct the air jet to the air pressure switch gauge c the pressure switch could be damaged iv Clean the fan blades using a stiff brush v Reinstall the internal access panel vi Reinstall the fan grille To replace the fan blade and the electric motor carry out the following procedure i Remove the air inlet grille a by removing four screws that secure it to the machine ii Loosen the screw d on the fan hub iii Extract the fan blades and replace with a new one respecting blades orientation iv Remove the top cover access panel b by removing four screws v Loosen three screws e on the fuel pump casing be sure not to remove the screws vi Remove fuel pump from electric motor and
16. oid valve and the unit stops e fuel circuit including suction and return hoses from fuel tank to fuel pump and high pressure microhose from fuel pump to nozzle e burner head e nozzle COMBUSTION CHAMBER For indirect heater it consists of e internal combustion chamber stainless steel made that containing the flames and e the external high efficient heat exchanger aluminated steel made that leads smokes to chimney stack For direct heater it consists of the internal combustion chamber stainless steel made that containing the flames and exhanges heat with the main airflow stream BURNER HEAD The burner head is the assembly that determines the correct mixing of combustion air and fuel inside the combustion chamber and it consists of e Fuel nozzle Nozzle support Flame diffuser Air opening baffle a screw fitted on the burner head allows the adjustment of combustion air setting Ignition electrodes Flame detector FAN MOTOR ASSEMBLY The electric motor drives the fuel pump assembly and a fan which blows air inside and around combustion chamber 2 FLAME CONTROL RUNNING FAILURE CYCLE 2 1 STARTING CYCLE Room thermostat Burner Fan Ignition Transformer Fuel Valve Photocell Reset Lamp 4 Ji 5 The flame control unit starts the sequence of operation after a heating request normal operation or thermostat operation and it consists of the following steps Self test less than 3 s self check of electronics effici
17. tions of fuel line from tank to fuel pump untightened connections can cause suction of air to fuel pump 5 Check fuel line are not obstructed or damaged and eventually replace 6 Check adjustment of fuel pump pressure li Flame failure because of bad combustion 1 Check and clean fuel nozzle eventually replace it 2 Check and clean combustion head nozzle nozzle support and diffuser disc 3 Check adjustment of fuel pump pressure 4 Check adjustment of combustion air ii Flame failure because of air pressure switch PA cutting in 1 Check fan is tightened on fan motor axle 2 Check there is no object obstructing air inlet 3 Check hose to air pressure switch are not obstructed 4 Check connections to electrical wirings of air pressure switch 5 Check and eventually replace air pressure switch iv Flame failure because of safety thermostat LI cutting in 1 Check there is no object obstructing air outlet 2 Check air outlet hose respect maximum length and diameter as specified 3 Check connections to electrical wirings of overheating thermostat 4 Check and eventually replace safety thermostat b Heater stops in stand by and reset lamp is off i Voltage lower than 70 V or higher than 150 V 1 Check supply voltage is correspondant to rating plate 2 Unit will automatically restart when voltage becomes higher than 80 V or lower than 140 V c Heater starts and stops flames and main fan remains on unit is in stand by and reset lamp is off i Air bubb
18. us waiting for heating request Lu steady orange light function not active SW steady green light unit is working normally starting cycle or working cycle HI steady red light the heater stops permanently in lock out status and can restart only if reset button is pressed 3 MAINTENANCE SCHEDULE Periodic maintenance of the heater is necessary to ensure proper performance and to prevent failures and it shall be performed at the following periodic intervals e Daily maintenance I Inspect air inlet air outlet and exhaust stack remove debris if any If any air hose is installed secure it is fixed Minimize bends and keeps ducts straight lii Verify fuel tank is full iv Verify that exhaust stack is properly installed e Weekly maintenance i Disassemble inspect and clean fuel filter with clean fuel li Remove top cover and clean the motor fan blade and the interior shell ii Inspect the fuel hose assembly and check for any leaks 6months maintenance i Disassemble burner head 1 Inspect and clean burner diffuser 2 nspect and replace nozzle if necessary 3 Clean ignition electrodes and adjust settings 4 Check air combustion setting li Check overheat thermostat Inspect and clean the combustion chamber iv Open electric board inspect electrical components and check connections v Check fuel pressure setting of fuel pump vi Inspect and test the burner 4 REPAIR PROCEDURES A WARNING Before carrying out any