Home
        Configuration Guide
         Contents
1.    Keysight Technologies  E4980A Precision LCR Meter  20 Hz to 2 MHz    E4980AL Precision LCR Meter  20 Hz to 300 kHz 500 kHz 1MHz    Configuration Guide       y    kia pee p        miu              z  U               KEYSIGHT    TECHNOLOGIES    E4980A E4980AL Configuration Guide Introduction    This guide helps you to define the options and accessories for the E4980A and E4980AL precision LCR meters     The E4980A is the model number of the 20 Hz to 2 MHz frequency range LCR meter  The E4980AL is the model  number of 20 Hz to either 300 kHz  500 kHz or 1 MHz frequency range LCR meter  The E4980AL is a distributor  preferred product     For configuring options  see this page for the E4980A  and page 8 for the E4980AL     E4980A Ordering Guide    The following steps will guide you through configuring your E4980A     Standard Furnished Item                Description Additional Information   CD ROM Contains User s Guide  in PDF  and Sample Program  See documentation option for  printed manuals    CD ROM Contains Keysight  O Libraries Suite  the latest versions     USB Cable USB  Type A  to USB  Type Mini B  cable   Power Cable       Certificate of Calibration       Note  Test Fixture and printed copy of User s Guide are not furnished  See Documentation Option and Available Accessories for the selection of    these items     Step 1  Choose Hardware Option  Mandatory           ME A   Not aa    Description Option No  Requires Camo Additional Information  Bias Current Interface E49
2.   Requires   Instrument must                                                                            1                          Description Model Number already include the Additional Information  following   SMD Test Fixture 6034E one For SMD   0 1 to 8 L x  0 5 to 10 W x  0 5 to 10 H mm   Operation and Service Manual is furnished   SMD Test Fixture 6034G one For SMD   0 1 to 5 L x  0 3 to 1 6 W x  0 3 to 1 6 H mm  100 Q  SMD resistors set is furnished   6034G ABA one U S    English localization   6034G ABJ one Japan   Japanese localization  SMD Test Fixture 6034H one For Array type SMD   0 1 to 5 L x   lt  15 W x  0 6 to 3 H  mm  100 Q SMD resistors set and Operation Manual are  urnished   SMD Test Fixture 6044A one elvin contact test fixture for SMD   1 6 to 8 L x  0 8 to 8 W x   0 8 to 3 H mm  6044A ABA one U S    English localization     6044A ABJ one Japan   Japanese localization   Test Fixture 6047A one For axial or radial lead device  Operation and Service Manual  is furnished   6047A 701 one Adds Shorting plate  Test Fixture 6047D one For axial or radial lead device  Operation and Service Manual  is furnished   6047D 701 one Adds Shorting plate  Test Fixture 6047E one For axial or radial lead device  6047E ABA one U S    English localization     6047E ABJ one Japan   Japanese localization     Test Leads 6048A one BNC connector leads  0 94 m  BNC connector bracket and  Operation and Service Manual are furnished   Test Leads 6048D one BNC connector leads  1 89 m  BN
3.  E4980A 001 and E4980A 002 can be installed in the same unit but cannot be operated simultaneously   Note 2  Refer to Software Upgrade for retrofit information on the above options     Step 3  Choose General Miscellaneous Accessory Option  If not required  go to Step 4        A      Not oe    Description Option No  Requires Compatible Additional Information  Rackmount Kit E4980A 1CM None None       Note  Front Handle Kit and Handle Rack Mount Kit are not available     Step 4  Choose Documentation Option  If not required  go to Step 5           Description Option No  Additional Information  U S    English Localization E4980A ABA Printed manuals are not furnished  Order documentation option if required   Japan   Japanese Localization E4980A ABJ    Step 5  Choose Calibration Certificate Option  If not required  go to Step 6     Description Option No  Additional Information  ISO 17025 Compliant Calibration E4980A 1A7 ISO 17025 compliant calibration  ANSI Z540 Compliant Calibration E4980A A6J ANSI Z540 compliant calibration    Step 6  Choose Warranty Plan  3 year Return to Keysight warranty and service plan are standard  For extended warranty options and additional information  contact  your local Keysight sales office or visit the Keysight home website        Hardware Upgrade                Requi  RE AE  sinit Desa ton Model No  or Customer od Not Additional  P i P Equivalent Part Installable   y Compatible Information  include the  Number 3  following   E4980A 002 Bias Current I
4. 80A 002 None 001 Adds a digital interface to allow the E4980A to control  See Notes 1 the 42841A Bias Current Source   and 2   The 42841A was discontinued in December 2012    Handler Interface E4980A 201 None one Adds handler interface  See Note 2   Scanner Interface E4980A 301 None one Adds scanner interface  See Note 2   No Interface E4980A 710 None one Attaches blank panel to the expansion slots  See Note 2           Note 1  The E4980A 001 and E4980A 002 can be installed in the same unit but cannot be operated simultaneously    Note 2  Up to 2 interfaces can be installed in the expansion slots on the rear panel  When no interface is added  two of the E4980A 710 are  installed  When one interface is added  that interface and the E4980A 710 are installed    Note 3  Refer to Hardware Upgrade for retrofit information on the above options     Step 2  Choose Software Option  If not required  go to Step 3           NE   s Not A     Description Option No  Requires Compatible Additional Information   Power and DC Bias E4980A 001 None 002 Increases test signal level range to 20 V 100 mA rms   Enhancement  See Note 1  max  Adds internal DC bias function controllable from O    40 V   100 mA dc  2nd DC source  and Rdc Vdc ldc  measurement functions    Entry Model E4980A 005 None None Low priced version  Same as basic model except for  difference in measurement time  slow speed     DCR Measurement E4980A 200 None Adds a DC resistance measurement    mandatory option           Note 1  The
5. C connector bracket and  Operation and Service Manual are furnished   Test Leads 6048E one BNC connector leads  3 8 m  BNC connector bracket and  0    Language selection of Operation and Service Manual                    peration and Service Manual are furnished     Available Accessories     General Measurement Accessories continued    Requires   Instrument must                                                                                  Description Model Number already include the Additional Information   following    Tweezers Test Fixture 6334A one For SMD   lt  10 mm L  Tweezers type  cable length 1 m   Shorting block and Operation and Service Manual are  furnished    Kelvin Clip Leads 6089A one 2 large clips  5 Hz   100 kHz  Choose mandatory option  16089A 800 or C20    Operation and Service Manual is furnished   6089A 800 one Cable length  1 m  standard   6089A C20 one Cable length  2 m   Kelvin Clip Leads 6089B one 2 medium clips  5 Hz   100 kHz  Choose mandatory option  16089B 800 or C20    Operation and Service Manual is furnished   6089B 800 one Cable length  1 m  standard   6089B C20 one Cable length  2 m   Kelvin IC Clip Leads 6089C one 2 IC clips  5 Hz   100 kHz  Cable length 1 m  Operation and  Service Manual is furnished    Alligator Clip Leads 6089D one 4 medium clips  5 Hz   100 kHz  Cable length 1 m  Operation  and Service Manual is furnished    Kelvin Clip Leads 6089E one 2 large clips  5 Hz   100 kHz  Cable length 1 m  Operation  Note is furnished    Ex
6. L 032  E4980ALU 052 Upgrade kit  300 kHz to 500 kHz  E4980AL 052 No  or E4980AL 032  When your unit model number is the E4980A    Upgrade Model No  or Description Option number to Customer Additional Information  Equivalent Part Number add  Installable  E4980ALU 111 Upgrade kit  500 kHz to 1 MHz for E4980A 100 0  E4980A  E4980ALU 110 Upgrade kit  300 kHz to 1 MHz for E4980A 100 0  E4980A  E4980ALU 050 Upgrade kit  300 kHz to 500 kHz E4980A 050 0 Installable at service center  or E4980A only  E4980ALU 201 Upgrade kit  E4980A 201 0  Handler Interface  E4980ALU 301 Upgrade kit  E4980A 301 o  Scanner Interface  5063 9241 Rackmount kit 5063 9241 Yes                   1   2     Note  For details of the upgrade information  refer to product homepage on the Keysight home website     The unit is ordered as the E4980AL before November 2014     E4980A AL option number     Software Upgrades  Not available    Accessory    Description Model Number Requires  Instrument must already include Additional Information  the following     40Vdc External Voltage Bias 160650  Adapter    Note  For other accessories  see the Available Accessories   General Measurement Accessories in page 5   For detailed information  refer to the Accessories Selection Guide for Impedance Measurements     Literature Resouce          Title Publication Number Additional Information  F4980A E4980AL Data Sheet 5989 4435E   E4980A Brochure 5989 4235E   E4980AL Brochure 5991 2305EN   E4980A Technical Overview  5989 4433E    M
7. igrating from a Keysight 4279A to n Keysight  E4980A Precision LCR Meter             E4980A Technical Overview  5989 4434E  Migrating from a Keysight 4284A to a Keysight  E4980A Precision LCR Meter          LCR Meters  Impedance Analyzers and 5952 1430E  Test Fixtures Selection Guide   Accessories Selection Guide For 5965 4 92E  Impedance Measurements   Impedance Measurement Handbook 5950 3000       Note  More literature is available on the Keysight home website     Web Resource    Have access to the following websites to acquire the latest news  product and support information  application litera     ture and more     http   www keysight com find impedance  http   www keysight com find e4980a  http   www keysight com find e4980al    11   Keysight   E4980A E4980AL Precision LCR Meter   Configuration Guide    myKeysight    LXI    WARRANTY          myKeysight    www keysight com find mykeysight  A personalized view into the information most relevant to you     www lxistandard org   LAN eXtensions for Instruments puts the power of Ethernet and the  Web inside your test systems  Keysight is a founding member of the LXI  consortium     Three Year Warranty   www keysight com find ThreeYearWarranty   Keysight s commitment to superior product quality and lower total cost  of ownership  The only test and measurement company with three year  warranty standard on all instruments  worldwide     Keysight Assurance Plans   www keysight com find AssurancePlans   Up to five years of protecti
8. nterface E4980AU 002 No None 001  See Installable at service  Note 1  center only  E4980A 201 Handler Interface E4980AU 201 No None None  E4980A 301 Scanner Interface E4980AU 301 No None None  E4980A 1CM Rackmount Kit 5063 9241 Yes None None  Note 1  The E4980A 001 and E4980A 002 can be installed in the same unit but cannot be operated simultaneously   The 42841A was discontinued in December 2012   Note 2  For details of the upgrade information  refer to product homepage on the Keysight home website     Software Upgrade             Requires  Upgrade  Instrument  Opticon No D  scribtion Model No  or Customer natasa Not Additional  P    P Equivalent Part Installable   y Compatible Information  include the  Number    following   E4980A 001 Power and DC Bias E4980AU 001 No None 002 Installable at service  Enhancement  See Note 1  center only  E4980A 007 Standard Model E4980AU 007 No E4980A 005 None Installable at service  center only  E4980A 200 DCR Measurement E4980AU 200 No None E4980A 001 Installable at service   See Note 2  center only       Note 1  The E4980A 001 and E4980A 002 can be installed in the same unit but cannot be operated simultaneously     Note 2  The DCR  Rdc  measurement becomes available with either E4980A 200 or E4980A 001   t is unnecessary to upgrade if the unit has the E4980A 001        Note 3  For firmware update and upgrade information  refer to product homepage on the Keysight home website     Available Accessories     General Measurement Accessories  
9. on and no budgetary surprises to ensure your  instruments are operating to specification so you can rely on accurate  measurements     www keysight com go quality  Keysight Technologies  Inc   DEKRA Certified ISO 9001 2008  Quality Management System    Keysight Channel Partners   www keysight com find channelpartners   Get the best of both worlds  Keysight s measurement expertise and product  breadth  combined with channel partner convenience     KEYSIGHT    TECHNOLOGIES    For more information on Keysight  Technologies  products  applications or  services  please contact your local Keysight     gt     mericas  Canada  Brazil   exico  United States       Asia Pacific  Australia  China  Hong Kong  India  Japan  Korea  Malaysia  Singapore  Taiwan  Other AP Countries    Europe  amp  Middle East  Austria  Belgium  Finland  France  Germany  reland  srael  taly  Luxembourg  etherlands  Russia  Spain  Sweden  Switzerland       United Kingdom    office  The complete list is available at   www keysight com find contactus     877  894 4414  55 113351 7010  001 800 254 2440   800  829 4444    800 629 485  800 810 0189  800 938 693  800 112 929  0120  421  345  080 769 0800  800 888 848  800 375 8100  0800 047 866   65  6375 8100       0800 001122  0800 58580  0800 523252  0805 980333  0800 6270999  1800 832700   1 809 343051  800 599100   32 800 58580  0800 0233200  8800 5009286  800 000154  0200 882255  0800 805353  Opt  1  DE   Opt  2  FR   Opt  3  IT   0800 0260637    For other unlis
10. rface options are not available  E4980AL 710 No interface is equipped as mandatory     Step 1  Choose Frequency Option  Specify the first two digits              Description Option No    20 Hz to 300 kHz E4980AL 032  20 Hz to 500 kHz E4980AL 052  20 Hz to 1 MHz E4980AL 102       Step 2  Add Accessory                   EF Keysight   Not z    Description Product No  Requires Compatible Additional Information  Rackmount Kit 1CMO19A Order rack mount kit separately if needed   Note  Front Handle Kit and Handle Rack Mount Kit are not available   Step 3  Add Documentation  Description Keysight Part number Additional Information  U S    English Localization E4980 90210 Printed manuals are not provided for free  They need to be ordered sepa   Japan   Japanese Localization E4980 97210 rately if needed  Step 4  Choose Warranty Plan  Description Option No  Additional Information       3 year Return to Keysight warranty and service is standard  The extended warranty option is available   Contact your local Keysight office or visit our web site for more information        Hardware Upgrades    When your unit model number is the E4980AL                                                           Upgrade Model No  or Description Option number to Customer Additional Information  Equivalent Part Number add  Installable  E4980ALU 113 Upgrade kit  500 kHz to 1MHz for E4980AL 102 No Installable at service center  E4980AL 052 only  E4980ALU 112 Upgrade kit  300 kHz to 1MHz for  E4980AL 102 No  E4980A
11. t must already                                        Description Model Number   Additional Information  include the  following   Open Termination 42090A one 4 terminal pair Open termination  Needed for performing  calibration   Short Termination 42091A one 4 terminal pair Short termination  Needed for performing  calibration   4 Terminal Pair Standard 6380A one 1 pF  10 pF  100 pF and 1000 pF standard capacitor set with  Capacitor Set carrying case  Calibration report and Operation Note are  furnished   4 Terminal Pair Standard 6380C one 0 01 pF  0 1 uF and 1 uF standard capacitor set with  Capacitor Set carrying case  Calibration report and Operation Note are  furnished   6380C 001 one Adds 10 uF standard capacitor  4 Terminal Pair Standard 42030A one 9 standard resistors from 1 mQ to 100 kQ in decade steps     Resistor Set    Carrying case  calibration report and Operation and Service  Manual are furnished           Note  For more detailed information  refer to Accessories Selection Guide for Impedance Measurements     E4980AL Ordering Guide    The following steps will guide you through configuring your E4980AL     Standard Furnished Item                Description Additional Information   CD ROM Contains User s Guide  in PDF  and Sample Program  See documentation option for  printed manuals    CD ROM Contains Keysight  O Libraries Suite  the latest versions     USB Cable USB  Type A  to USB  Type Mini B  cable   Power Cable    Calibration of Certification       Note  Inte
12. ted countries   www keysight com find contactus     BP 09 23 14     This information is subject to change without notice      Keysight Technologies  2013   2014  Published in USA  December 5  2014    5989 8321EN  www keysight com    
13. ternal Voltage Bias Fixture 16065A one   200 V dc max   for axial or radial lead device    Shorting plate and Operation and Service Manual  are furnished    Dielectric Test Fixture 6451B one Test fixture for measuring permittivity of dry solid sheet  material  Cable length 1 m    38 mm and 5 mm diameter electrodes for measuring bare  material and two types of electrodes for measuring material  with pre formed electrodes are furnished    16451B ABA None U S    English localization    16451B ABJ None Japan   Japanese localization     1     Language selection of Operation and Service Manual     Available Accessories     General Measurement Accessories continued    Requires   Instrument must       Description Model Number already include the Additional Information  following    Liquid Test Fixture 16452A None Test fixture for measuring permittivity of liquid material    16048A or 16452  Required volume of material  3 4  3 8  4 8 or 6 8 ml  Tem   61601 Test Leads perature range   20    to  125   C  Shorting plate  spacers   recommended  SMA BNC adapters  fixture stand  carrying case and Opera    tion and Service Manual are furnished   Test Leads 16048G  BNC  m m  None Heat proof test leads for use with the 16452A  Temperature    adapter x 4  p n  1250 0216 x 4     range   20    to  150   C       Note  For more detailed information  refer to Accessories Selection Guide for Impedance Measurements     Available Accessories     for Calibration and Maintenance    Requires  Instru   men
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
ecocut sa-104  取扱説明書  Rhino-Rack® Heavy Duty 2500 Silver Roof Rack  Avaya BCM450 User's Manual    YAP 18  I MANUALE D`USO E MANUTENZIONE GB USE AND - NH  6. Installing the Switch 1. Package Contents 3. Switch Top Panel 5  1117_bosch_cp_web_hagaki  Descargue el folleto del producto    Copyright © All rights reserved. 