Home
        rps9 user guide ap0334_3
         Contents
1.      The RPS9 can be operated as a free standing unit without requiring any special cooling arrangement  but should not be  accidentally or deliberately covered in any way  Always stand the unit on a firm flat surface well away from any soft furnishings  such as carpets or curtains     Rack Mounting    The RPS9 is designed as a 19 inch rack mount unit and will occupy 2U  3 5 inches  of rack space   An important consideration when rack mounting the unit is the need for natural convection of air flow over the whole unit   Good ventilation below the unit  in the floor or back of the rack  will ensure a path for continuous air flow     Other equipment in the rack which is known not to produce a significant amount of heat should be mounted below the unit   Equipment which also relies on good air flow within the rack  i e  most power amplifiers and other power supplies  should be given  due consideration and some space should be provided between such units and between the RPS9 unit  Forced convection  by  means of a fan tray  may be desirable in this situation     Location    As with any power supply that contains a mains voltage transformer  it is recommended that the RPS9 is physically separated from  other equipment  particularly that which carries low level audio signals  to avoid any possible hum pick up  For this reason the unit  is provided with a long  3m  output cable to enable it to be positioned away from the mixing console  For the same reason  when  rack mounting it is
2.    USER  GUIDE    PUBLICATION AP0334    LIMITED ONE YEAR WARRANTY    This product has been manufactured in the UK by ALLEN  amp  HEATH and is warranted to be free from defects in materials or  workmanship for a period of one year from the date of purchase by the original owner     To ensure the high level of performance and reliability for which this equipment has been designed and manufactured please read  the User Guide before use     In the event of a failure notify and return the defective unit to ALLEN  amp  HEATH or its authorised agent as soon as possible for  repair under warranty subject to the following conditions     CONDITIONS OF WARRANTY     1  The product has been installed and operated in accordance with the instructions in the installation instructions in the User  Guide     2  The product has not been subject to misuse either intended or accidental  neglect  or alteration other than as described in the  installation instructions in the User Guide or approved by ALLEN  amp  HEATH     3  Any necessary adjustment  alteration  or repair has been made by ALLEN  amp  HEATH or it s authorised agent   4  The defective unit is to be returned carriage prepaid to ALLEN  amp  HEATH or it s authorised agent with proof of purchase   5  Units to be returned should be packed to avoid transit damage     These terms of warranty apply to UK sales  In other territories the terms may vary according to legal requirements     Allen  amp  Heath Agent     ALLEN  amp  HEATH   Kernick 
3.  SHOULD BE UNDERTAKEN ONLY AFTER  DISCONNECTING THE MAINS SUPPLY LEAD FROM THE POWER SUPPLY UNIT    The RPS9 power supply unit requires no internal maintenance or regular servicing  If the RPS9 requires servicing or repair then refer  to the service manual for the power supply or contact your Allen  amp  Heath dealer     
4.  at the  output of the power supply unit     RPSY    O ABWERSUPPLY    RPS9 power supplv to mains electricitv        T IMPORTANT  Please read this manual carefully before connecting your    This product complies with the European Electromagnetic Compatibility directives 89 336 EEC  amp  92 31 EEC  and the European Low Voltage directive 73 23 EEC  amp  93 68 EEC     Warning to the User Installer Service Engineer    Allen  amp  Heath warns that any unauthorised changes or modifications to the RPS9 unit may invalidate the  legal compliance of the unit and could void the user   s authority to operate the equipment        Precautions and Safety instructions    General Precautions    Avoid storing or using the RPS9 in conditions of excessive heat or cold  or in positions where it is likely to be subjected to  vibration  dust or moisture  Do not use any liquids to clean the exterior of the unit  A soft  dry cloth or brush is ideal           SOLVENTS MAY CAUSE DAMAGE TO PAINT OR PLASTIC PARTS    Handling and Transport   The RPS9 is supplied in a specially designed cardboard box  If it is necessary to move the unit any distance after installation  it is  recommended that this carton is used to protect it  Be sure to disconnect all cabling before moving  If the RPS9 is to be moved  regularly  e g  touring  it is recommended that it is installed in a foam lined case  At all times avoid applying excessive force to any  switches or connectors     Installation of the RPS9    Free Standing  
5.  preferable to avoid locating the unit adjacent to signal processing equipment     Earthing    Finally  some consideration should be given to the earthing arrangement of the system at the centre of which is the console and  the RPS9  The console chassis is earthed  to mains earth via the power supply  When rack mounting the RPS9 care should be  taken to avoid any possible    ground loops    in the system which would introduce audible hum to otherwise clean audio signals   Ground loops may occur where signal processing equipment  patched to the console  has its signal earth connected to the  equipment chassis  A ground loop is formed if the chassis of the signal processing equipment and the RPS9 chassis are in electrical  contact through the fixing rails they share in the rack  The RPS9 includes a    ground lift    switch on the rear panel  This isolates the  audio OV from the chassis earth  Operation of this switch may alleviate hum caused by a ground loop  Note that this will not  disconnect the console chassis from mains earth  which must remain connected at all times        Using the RPS9    ALWAYS MAKE SURE THAT THE POWER SUPPLY HAS BEEN SET TO THE SAME AC  MAINS VOLTAGE AS PROVIDED FROM THE MAINS SOCKET OUTLET    Always switch the power supply off before connecting or disconnecting the console power cable  removing or installing modules  and servicing  In the event of an electrical storm  or large mains voltage fluctuations  immediately switch off the power supply and  d
6. Industrial Estate   Penryn    Cornwall    England    TR10 9LU    www allen heath com  Tel  01326 372070  Fax  01326 377097    H A division of Harman International Industries Ltd     copyright    1999 ALLEN  amp  HEATH  All rights reserved   Publication AP0334 Issue 3  IMcB 9 8 99    Information in this manual is subject to change without notice and does not represent a commitment on the part of the vendor   ALLEN  amp  HEATH shall not be liable for any loss or damage whatsoever arising from the use of information or any error contained  in this manual     No part of this manual may be reproduced  stored in a retrieval system  or transmitted  in any form or by means  electronic   electrical  mechanical  optical  chemical  including photocopying and recording  for any purpose without the express written  permission of ALLEN  amp  HEATH     It is recommended that all maintenance and service on the product should be carried out by ALLEN  amp  HEATH or its authorised  agents  ALLEN  amp  HEATH cannot accept any liability whatsoever for any loss or damage caused by service  maintenance or repair  by unauthorised personnel     RPS9 Power Supply    INTRODUCING THE RPS9    The RPS9 is a linear power supply which  like other linear supplies  produces DC voltages by rectifying  smoothing and regulating  AC voltages from the secondary windings of a mains transformer     Allen  amp  Heath mixing consoles employ a number of DC voltage supply levels in their operation and these are provided
7. LTS 2 5A Max    16 VOLTS 2 5A Max    48 VOLTS 100mA Max     DC Output Socket Pin Connections    Pinl    16 Volts  Pin2   AUDIO 0V  Pin3   CHASSIS 0V  Pin4    16 Volts  Pin5    48 Volts  Overall Dimensions  Front Panel Chassis  Maximum External   19 inch 2U  482mm x 88mm  Height  78mm including feet  3 07 inches     Width  400mm _  15 75 inches   Depth  130mm _  5 12 inches   Weight  5Kg  11 pounds     Servicing  THIS UNIT CONTAINS NO USER SERVICEABLE PARTS  REFER ALL SERVICING TO A  QUALIFIED SERVICE ENGINEER  THROUGH THE APPROPRIATE ALLEN  amp  HEATH DEALER  Initial operational tests on the power supply can be carried out by switching the unit ON and checking the front panel LED    indicator is illuminated  If the LED indicator is not illuminated  check the fuses are intact in the mains plug  where fitted  and the  unit fuseholder on the rear panel     THIS OPERATION SHOULD ONLY BE CARRIED OUT BY A TECHNICALL Y COMPETENT  PERSONNEL    If the front panel LED indicator is illuminated but the console appears not to have any power then it may be necessary to check the    voltages present on the output connector  Refer to the Technical Specification section in this manual for the DC output voltage  levels     Any fault condition  with the exception of simple fuse failures  will require access to the internal assemblies of the power supply     Servicing Components    ALL SERVICE AND REPAIR WORK MUST ONLY BE CARRIED BY TECHNICALLY COMPETENT  PERSONNEL  REPLACEMENT OF ANY COMPONENTS
8. isconnect from the mains supply    During normal operation some heat is generated  This is dissipated by the rear heatsink and chassis ventilation              DO NOT COVER THE UNIT DURING OPERATION    THIS UNIT CONTAINS NO USER SERVICEABLE PARTS  REFER ALL SERVICING TO A  QUALIFIED ENGINEER  THROUGH THE APPROPRIATE DEALER NETWORK    Mains Voltage Setting          SPECIAL ATTENTION SHOULD BE GIVEN TO THE FOLLOWING INFORMATION    The RPS9 is capable of operating over a wide range of AC mains input voltages by means of a mains voltage selector  It is  important to check that the RPS9 has the correct voltage setting as marked on the rear panel of the power supply  Confirm that the  voltage setting matches the local AC mains supply in your area     DO NOT CHANGE THE AC MAINS VOLTAGE SETTING WITHOUT FIRST DISCONNECTING THE  MAINS LEAD FROM THE AC MAINS SOCKET    To alter the setting of the AC mains  WAC MAINS IN     input voltage  lever out the fuseholder    with a suitable tool  Pull the fuse carrier  assembly clear of the unit and rotate it    Check the arrow indicates  the correct AC mains       until the required voltage aligns with the  arrow  Push the fuse carrier back into  place    Check the correct fuse is fitted for the  selected mains input voltage     voltage setting for your  local AC mains supply        Set the voltage selector to   100 V for ac mains input voltages between 100 115 V ac  120 V for ac mains input voltages between 115 125 V ac    220 V for ac mains inp
9. ut voltages between 210 230 V ac  230 V for ac mains input voltages between 230 264 V ac    DO NOT ATTEMPT TO USE THE POWER SUPPLY IF IT IS SET TO A DIFFERENT AC MAINS  INPUT VOLTAGE TO THE LOCAL AC MAINS SUPPLY IN YOUR AREA    DO NOT USE DC MAINS INPUT VOLTAGES          The power supply is provided with an IEC type mains connector and a moulded mains plug  Check that this is suitable for  connection to the wall socket outlet     Replacing Mains Fuse       The AC mains fuse is located on the rear of the RPS9 unit next to the AC mains connector  In the event of a mains surge or under   rated fuse value  the mains input fuse will rupture  Switch off the power supply and remove the mains lead plug from the    AC  MAINS IN    socket on the rear of the unit     Check the fuse and replace if necessary  Check also the AC mains input voltage setting is correct for the mains supply in your area  before switching the unit on again     TO AVOID THE RISK OF FIRE REPLACE FUSE WITH THE CORRECT TYPE ONLY  AS  INDICATED ON THE UNIT    In the event of repeated failure of the mains fuse  consult the local dealer from where the unit was purchased     AC MAINS VOLTAGE SETTING FUSE RATING  220 230 VAC T 1A  250V  100 120 VAC T 3 15A   250V    Technical Specification    Mains Input Voltage Settings  230 220 120 100 VAC   47 63 Hz    Power consumption  max    150W    Mains Fuse Rating    100 120 V  Use T 3 15A 250V 20mm  220 240 V  Use T 1A 250V 20mm  Outputs  DC Voltage Rail Output Current   16 VO
    