Home

KX-TDA50 V 50 PT Programming 3823va

image

Contents

1. Fixed Buttons Function KX NT300 KX DT300 KX NT136 KX T7600 KX T7200 KX T7400 A A 5 PREVIOUS gt ENTER ENTER SP PHONE NEXT Y Y amp N h mp FWD DND Page up genren 8 euren LL lt s Page down o o s ENTER 59 0 Back to Previous Menu CANCEL SHIFT SHIFT SHIFT O PROGRAM 7 PAUSE PROGRAM HOLD HOLD HOLD END 0 MESSAGE eet T SELECT 16 PT Programming Manual Document Version 2008 11 2 1 1 Programming Instructions Fixed Buttons Function KX NT300 KX DT300 KX NT136 KX T7600 KX T7200 KX T7400 RECALL RECALL m FLASH 3 TRANSFER CLEAR INTERCOM INTERCOM INTERCON SECRET The buttons shown in this column are from the KX T7400 series Entering System Programming Mode Using a PT to perform system programming allows an authorized extension user to set a wide range of PBX features and parameters There are two levels of system programming that can be performed with a PT administrator level programming and user level programming Administrator Level Allows the programming of all settings accessible through PT programming System Password for Administrator Q p p gt y i Programming No for PT Programming PROGRAMI 3 digits PAUSE 1234 User Level Allows the programming of l
2. 46 800 RS 232C Parameter Parity Bit 46 800 RS 232C Parameter Stop Bit Length 46 801 External Modem Control 46 802 SMDR Page iE phe 46 803 SMDR Skip Perforation a 46 804 SMDR Outgoing Call Printing ener ea 47 805 SMDR Incoming Gall Printing ooo Laert urinveiene 47 810 Remote Programming 2 47 811 Modem Floating Extension Number 47 812 ISDN Remote Floating Extension Number KX TDA 100 KX TDA200 KX TDA600 prete TR 47 2 1 12 Card 47 6 PT Programming Manual Document Version 2008 11 Table of Contents 900 Slot Card Type Reference 47 901 Slot Card Deletion NN 48 902 Slot Card Reset usus DU 48 910 OPB3 Option Card Type Reference KX TDA100 KX TDA200 KX TDA600 MM 48 911 OPB3 Option Card Deletion KX TDA100 KX TDA200 KX TDA600 only 48 3 ABBODODE sr 49 3 1 ENEE 50 3 1 1 KX TDA100 KX TDA200 PMPR Software File Version 3 2XXX 50 3 1 2 KX TDA100 KX TDA200 PMPR Software File Version 5 0xxx 50 3 1 3 KX TDA50 PSMPR Software File Version 4 0 50 3 1 4 KX TDA50 PSMPR Software File Version 5 50 3 2 Feature Programming Ref
3. 660 VM Group Floating Extension Number 660 gt e gt gt gt E KX TDA50 1 KX TDA50 500 END ENTER KX TDA100 1 2 KX TDA100 Group 1 500 ENTER KX TDA200 1 2 KX TDA200 Group 1 500 KX TDA600 1 8 KX TDA600 Group 1 500 680 Idle Extension Hunting Type 680 gt HuntingGroupNo gt ED rer DI KX TDA50 01 64 amp Circular END ENTER KX TDA100 01 64 Terminate ENTER KX TDA200 01 64 KX TDA600 001 128 681 Idle Extension Hunting Group Member 681 gt gt ning GroupWo gt gt KX TDA50 01 64 01 16 ENTER KX TDA100 01 64 KX TDA200 01 64 KX TDA600 001 128 gt gt En gt gt a END ENTER 690 PS Registration 690 gt 57 gt gt G E peere E ENTER See below 1 4 digits ENTER below KX TD7690 KX TDA50 001 028 gt KX TDA100 001 128 gt e dr KX TDA200 001 128 KX TDA600 without EMEC 001 256 J Em ZER KX TDA600 with EMEC 001 512 Be seconds Note Please refer to the Installation Manual for details about PS registration 42 PT Programming Manual Document Version 2008 11 2 1 10 Resource Interface Programming 691 PS Termination 691 gt e PSNo gt gt Im END ENTER See below ENTER KX TDA50 001 028 KX TDA100 001 128 KX TDA200 001 128 KX TDA600 001 512 692 Personal Identification Number PIN for PS Registration 692 gt e
4. Links to Other Pages and Manuals 2 If you are viewing this manual with a PC certain items are linked to different sections of the PT Programming Manual and other Hybrid IP PBX manuals Click on a link to jump to that section Linked items include e PT Programming Manual References Feature Manual References PT Programming Manual Document Version 2008 11 Introduction Safety Notices Please observe the safety notices in this manual in order to avoid danger to users or other people and prevent damage to property The notices are classified as follows according to the severity of injury or damage WARNING This notice means that misuse could result in death or serious injury CAUTION This notice means that misuse could result in injury or damage to property WARNING Unplug the PBX from the AC outlet if it emits smoke an abnormal smell or makes unusual noise These conditions can cause fire or electric shock Confirm that smoke has stopped and contact an authorized Panasonic Factory Service Center NOTES The contents of this manual apply to PBXs with a certain software version as indicated on the cover of this manual To confirm the software version of your PBX see 190 Main Processing MPR Software Version Reference Some optional service cards PTs and features are not available in some areas Additionally some optional service cards and features are not available for some PBX models Please c
5. 23 111 System Password for User for PT Programming nenn 23 112 Manager 23 120 Verification 24 121 Verification Code 24 122 Verification Code Personal Identification Number PIN ceecee 24 123 Verification Code COS 24 190 Main Processing MPR Software Version Reference 24 2 1 5 Tre PENN Meer 25 200 Hold Recall Time 25 201 Transfer Recall 25 203 Intercept 8 25 204 Hot Line Waiting Time 25 205 Automatic Redial Repeat Times KX TDA100 KX TDA200 KX TDA600 M 25 207 Door Unlock Time 25 208 Call Duration Count Starting Time for LCOT 26 26 210 DISA CO to CO Line Call Prolong Time III II I HN 26 211 DISA Intercept Time 26 2 1 6 TERS ARS Progfammiig 2222 EM 26 300 TRS Override by System Speed Dialing 26 301 TRS Denied Code are ee nee ee 26 302 TRS Exception Code 27 303 Special Carrier Access Code 27 304 Emergency Number Mm 27 320 ARS Mods EE 27 PT Programming Manual Document Version 2008 11 Table of Contents 321 ARS Leading Number 27 322 ARS Routing Plan Table Numb
6. 509 TRS Level for System Speed Dialing 509 gt 05 gt Cie gt I 01 64 1 7 END ENTER 1 510 TRS Level for Extension Dial Lock 510 gt gt Kos gt Ce 2 _ END ENTER a ENTER 511 Manager Assignment 511 amp COSNo gt gt r 01 64 Disable Enable END ENTER Only COS No 64 ENTER is set to Enable Document Version 2008 11 PT Programming Manual 35 2 1 8 COS Programming 512 Permission for Door Open Access 512 gt 01 64 Disable END ENTER Enable ENTER 514 Time Service Manual Switching 514 gt gt t0SWo gt 5 gt a 01 64 Disable END ENTER Enable ENTER 515 Wireless XDP Parallel Mode for Paired Telephone 515 gt er gt SP rer END 01 64 Disable ENTER Enable ENTER 516 Programming Mode Limitation 516 lt 4 gt COSNo gt SP rer 01 64 Disable Personal END ENTER System amp Personal ENTER COS No 01 63 Personal COS No 64 System amp Personal 36 PT Programming Manual Document Version 2008 11 2 1 9 Extension Programming 2 1 9 Extension Programming 600 EXtra Device Port XDP Mode 600 gt gt SlotNo gt PotNo gt S er her ANS MESSAGE END ENTER ENTER HOLD To the Next Port No To the Desired Port No NEXT CANCEL 601 Terminal Device Assignment 601 gt er S
7. KI 000 999 Max 32 digits END ENTER ENTER To the Next Speed Dialing No To the Desired Speed Dialing No ENTER v NEXT CANCEL 002 System Speed Dialing Name 002 e SpeedDiaingNo gt Name gt gt 000 999 Max 20 characters END ENTER ENTER 20 PT Programming Manual Document Version 2008 11 2 1 3 Basic Programming 003 Extension Number 003 gt e gt Curent Exi No gt ew Ean Ne I 101 END ENTER ENTER Note Extension numbers of PSs can be a maximum of 4 digits lf PC Phone PC Console or a CTI application is running on a PC connected to an extension whose extension number is to be programmed modified quit the application first 004 Extension Name 004 gt e Exn No Name gt e Max 20 characters END ENTER ENTER 005 Extension Personal Identification Number PIN 005 gt Extn No gt PN O I iai END ENTER Max 10 digits ENTER CAUTION There is a risk that fraudulent telephone calls will be made if a third party discovers a personal identification number PIN verification code PIN or extension PIN of the PBX The cost of such calls will be billed to the owner renter of the PBX To protect the PBX from this kind of fraudulent use we strongly recommend a Keeping PINs secret b Selecting complex random PINs that cannot be easily guessed Changing PINs frequently 006 Operator Assignment 006 gt e g
8. ENTER Ce ENTER Document Version 2008 11 PT Programming Manual 25 2 1 6 TRS ARS Programming 208 Call Duration Count Starting Time for LCOT 208 gt er Tim gt er ENTER 5 E 209 DISA Delayed Answer Time 209 gt m gt E END ENTER Po ENTER 210 DISA CO to CO Line Call Prolong Time 210 gt gt m gt gt KI EX fil END ENTER un ENTER 211 DISA Intercept Time 211 gt e gt gt m gt gt END 1 Day 2 Lunch 0 60 s ENTER 3 Break 4 Night 405 2 1 6 TRS ARS Programming 300 TRS Override by System Speed Dialing 300 gt gt gt COB gt IDI AUTO ANS MESSAGE END ENTER Disable 9 Enable ENTER HOLD 301 TRS Denied Code 301 gt gt Level No gt Location No gt Denied Code gt rt 2 6 001 100 Max 16 digits END ENTER ENTER To the Next Location No To the Desired Location No ENTER v NEXT CANCEL 26 PT Programming Manual Document Version 2008 11 2 1 6 TRS ARS Programming 302 TRS Exception Code 302 gt en Level Location gt Exception Code r igi END ENTER 2 6 001 100 Max 16 digits ENTER 303 Special Carrier Access Code 303 gt gt Location No gt Camer Access Cod gt gt KI END KX TDA50 01 20 Max 16 digits ENTER KX TDA100 01 20 ENTER KX TDA200 01 20 KX TDA600 001 100 304
9. you must press this button or the FWD DND button after entering the first character f SELECT is pressed the characters for each button will be displayed in reverse order To toggle between Table 1 and Table 2 when using the KX NT300 KX DT300 KX T7600 series press the leftmost soft button Document Version 2008 11 PT Programming Manual 13 1 1 3 Entering Characters 14 PT Programming Manual Document Version 2008 11 Section 2 PT Programming This section serves as reference operating instructions when using a display PT to program the PBX Document Version 2008 11 PT Programming Manual 15 2 1 1 Programming Instructions 2 1 PT Programming 2 1 1 Programming Instructions Required Telephone Extension PBX settings can be customized through system programming by using a proprietary telephone PT with a multiline display such as the KX NT343 or KX DT346 To access system programming the Class of Service COS assigned to the PT s extension must be programmed to allow system programming or the PT must be connected to the lowest numbered port on the card installed in the lowest numbered slot Only one system programming session can be performed at a time This means that only one user can access system programming at a time whether through a PT or PC For a list of characters that can be entered during system programming see Section 1 1 3 Entering Characters Buttons and Functions
10. OGM Floating Extension Number 4 731 Outgoing Message OGM Name 811 Modem Floating Extension Number 812 ISDN Remote Floating Extension Number KX TDA100 KX TDA200 KX TDA600 only Feature Manual References 6 1 5 Floating Extension FWD Call Forwarding e 472 Extension to CO Line Call Duration 473 CO to CO Line Call Duration 504 Call Forwarding to CO Line 605 Call Forwarding No Answer Time Feature Manual References 6 1 6 FWD Call Forwarding Host PBX Access Code Access Code to the Telephone Company from a Host PBX 471 Host PBX Access Code Feature Manual References 8 1 5 Host PBX Access Code Access Code to the Telephone Company from a Host PBX Hot Line 204 Hot Line Waiting Time 56 PT Programming Manual Document Version 2008 11 3 2 Feature Programming References Feature Manual References 8 1 6 Hot Line ICD Group Features 620 Incoming Call Distribution Group Member 621 Incoming Call Distribution Group Delayed Ringing 622 Incoming Call Distribution Group Floating Extension Number 623 Incoming Call Distribution Group Name 624 Incoming Call Distribution Group Distribution Method 625 Destination for Overflow Time Expiration 626 Overflow Time 627 Destination When All Busy 628 Queuing Call Capacity 629 Queuing Hurry up Level 630 Queuing Time Table 631 Sequences in Queuing Time Table 632 Maximum Number
11. gt Distribution ENTER Group No 001 128 gt gt gt DJ END ENTER gt Location No gt Extn No gt gt KX TDASO 01 32 KX TDA100 01 32 KX TDA200 01 32 KX TDA600 001 128 621 Incoming Call Distribution Group Delayed Ringing Incoming Call 621 gt Distribution ENTER Group No 001 128 lt lt gt FJ END ENTER 38 PT Programming Manual gt LocationNo gt ER KX TDA50 01 32 Immediate KX TDA100 01 32 1 6 rings KX TDA200 01 32 No ring KX TDA600 001 128 Document Version 2008 11 2 1 9 Extension Programming 622 Incoming Call Distribution Group Floating Extension Number 622 gt e gt Incoming Call Distribution ENTER Group No 001 128 623 Incoming Call Distribution Group Name 623 ee Incoming Call Distribution ENTER Group No 001 128 624 Incoming Call Distribution Group Distribution Method 624 er Incoming Call gt cn gt C gt Distribution e Ring UCD ENTER Group No Priority Hunt ENTER 001 128 625 Destination for Overflow Time Expiration Incoming Call 625 gt er DE Destination No ENTER Group No Break Night an 001 128 gt gt E 626 Overflow Time 626 gt er Incoming Call Overflow Time gt gt Ga Distribution None 1 125 x10 s END ENTER Group No ENTER 001 128 Document Version 2008 11 PT Programming
12. gt PlNforPSRegistration gt e gt ED 4 digits END ENTER 1234 699 CS Status Reference 699 gt gt gt Pais gt Can gt I END ENTER Reference only 2 1 10 Resource Interface Programming 700 External Pager Floating Extension Number KX TDA100 KX TDA200 KX TDA600 700 gt gt Far gt gt gt KD 1 2 END Pager 1 600 ENTER 9 ENTER HOLD To the Next Pager No To the Desired Pager No Y NEXT CANCEL KX TDA50 700 e gt PagerNo gt gt er ENTER ENTER HOLD Document Version 2008 11 PT Programming Manual 43 2 1 10 Resource Interface Programming 710 Music Source Selection for BGM with the KX TDA50 BGM2 with the KX TDA100 KX TDA200 KX TDA600 SELECT 710 E d AUTO ANS e MESSAGE ENTER Eier al ts nal ENTER Internal2 711 Music on Hold 711 gt gt gt KX TDA50 Tone BGM END ENTER KX TDA100 Tone BGM1 2 ENTER KX TDA200 Tone BGM1 2 KX TDA600 Tone BGM1 2 712 Music for Transfer 712 gt r ser gt Go OI ENTER Rng back ENTER 720 Doorphone Call Destination KX TDA100 KX TDA200 KX TDA600 720 gt e gt Time gt Slot No gt Card No and Port No gt gt 1 Day 2 Lunch 1 3 1 4 ENTER 3 Break 4 Night lt lt Destination gt Gr iai END Max 32 digits ENTER KX TDA50 720 gt e gt Timeno gt SiotN
13. 3 2 Feature Programming References Verification Code Entry 120 Verification Code 121 Verification Code Name 122 Verification Code Personal Identification Number PIN 123 Verification Code COS Number Feature Manual References 19 1 1 Verification Code Entry Virtual PS 690 PS Registration Feature Manual References 19 1 2 Virtual PS Voice Mail VM Group 601 Terminal Device Assignment 660 VM Group Floating Extension Number Feature Manual References 19 1 3 Voice Mail VM Group Voice Mail DPT Digital Integration 201 Transfer Recall Time Feature Manual References 19 1 4 Voice Mail DPT Digital Integration Walking COS 005 Extension Personal Identification Number PIN Feature Manual References 20 1 1 Walking COS Walking Extension 007 DSS Console Paired Telephone Feature Manual References 20 1 2 Walking Extension 64 PT Programming Manual Document Version 2008 11 3 2 Feature Programming References Wireless XDP Parallel Mode 515 Wireless XDP Parallel Mode for Paired Telephone Feature Manual References 20 1 4 Wireless XDP Parallel Mode Document Version 2008 11 PT Programming Manual 65 Panasonic Consumer Electronics Company Division of Panasonic Corporation of North America One Panasonic Way Secaucus New Jersey 07094 http www panasonic com csd Copyright This material is copyrighted by Panasonic Communications Co Ltd and may be reproduced fo
14. Extension Name Feature Manual References 13 1 21 Private Network Features QSIG CLIP COLP Calling Connected Line Identification Presentation and CNIP CONP Calling Connected Name Identification Presentation PS Connection 690 PS Registration 691 PS Termination 692 Personal Identification Number PIN for PS Registration Feature Manual References 13 1 24 PS Connection PS Directory e 001 System Speed Dialing Number 002 System Speed Dialing Name 004 Extension Name Feature Manual References 13 1 25 PS Directory PS Ring Group 620 Incoming Call Distribution Group Member Feature Manual References 13 1 27 PS Ring Group Document Version 2008 11 PT Programming Manual 61 3 2 Feature Programming References PT Programming 2 1 PT Programming 516 Programming Mode Limitation Feature Manual References 13 1 28 PT Programming Redial Last Number 205 Automatic Redial Repeat Times KX TDA100 KX TDA200 KX TDA600 only Feature Manual References 15 1 1 Redial Last Number SMDR Station Message Detail Recording e 800 RS 232C Parameter New Line Code e 800 RS 232C Parameter Baud Rate 800 RS 232C Parameter Word Length 800 RS 232C Parameter Parity Bit e 800 RS 232C Parameter Stop Bit Length 802 SMDR Page Length 803 SMDR Skip Perforation 804 SMDR Outgoing Call Printing 805 SMDR Incoming Call Printing Feature Manual References
15. KX TDA100 01 10 4 None ENTER KX TDA200 01 10 None For programs 331 to 340 when Priority 1 is selected the default value of Carrier Table No is as follows 331 01 332 02 333 03 334 04 335 05 336 06 337 07 338 08 339 09 340 10 347 ARS Routing Plan Table 1 48 KX TDA600 only 347 gt gt P nTableie gt ARSTmeNa P gt gt 1 6 01 48 1 TimeA 2 TimeB ENTER 3 TimeC 4 TimeD gt gt Carrier Table No gt 9 1 48 None END ENTER 28 PT Programming Manual Document Version 2008 11 2 1 7 CO Line Programming 350 ARS Carrier Name 350 gt gt CarierTableno gt Name gt I KX TDA50 01 10 Max 20 characters END ENTER KX TDA100 01 10 ENTER KX TDA200 01 10 KX TDA600 01 48 351 ARS Trunk Group for Carrier Access 351 gt gt Carrier Table No Trunk Group gt 220 e Disable KX TDA50 01 10 KX TDA50 01 64 ENTER KX TDA100 01 10 KX TDA100 01 64 Enable ENTER KX TDA200 01 10 KX TDA200 01 64 KX TDA600 01 48 KX TDA600 01 96 352 ARS Removed Number of Digits for Carrier Access 352 gt gt Carrier Table No gt Digits to Remove lt gt ED END KX TDASO 01 10 0 15 ENTER KX TDA100 01 10 0 ENTER KX TDA200 01 10 KX TDA600 01 48 353 ARS Carrier Access Code 353 gt Carrier Table No Carrier Access Code gt KX TDA50 01 10 M
16. KX TDA600 01 96 gt gt Host PBX Access Code gt lt gt m END Max 10 digits ENTER 472 Extension to CO Line Call Duration 472 gt gt Trunk Group No gt gt 69 gt E END KX TDA50 01 64 01 60 min ENTER KX TDA100 01 64 10 min ENTER KX TDA200 01 64 KX TDA600 01 96 473 CO to CO Line Call Duration 473 gt lt gt Trunk Group gt gt gt 3 KX TDA50 01 64 01 60 min END ENTER KX TDA100 01 64 10 min ENTER KX TDA200 01 64 KX TDA600 01 96 32 PT Programming Manual Document Version 2008 11 2 1 7 CO Line Programming 475 DISA Silence Detection 475 gt gt Trunk Group gt ED rer SELECT END KX TDA50 01 64 No Detect ENTER KX TDA100 01 64 Detect ENTER KX TDA200 01 64 KX TDA600 01 96 476 DISA Continuous Signal Detection 476 gt er TrunkGroupNo ED Sr KX TDA50 01 64 No Detect END ENTER KX TDA100 01 64 Detect ENTER KX TDA200 01 64 KX TDA600 01 96 477 DISA Cyclic Signal Detection 477 gt er TrunkGroupNo gt gt DI SELECT END KX TDA50 01 64 No Detect ENTER KX TDA100 01 64 Detect ENTER KX TDA200 01 64 KX TDA600 01 96 490 Caller ID Signal Type 490 gt Sitno gt CED gt er with END SES Visual Caller ID DTMF ENTER Document Version 2008 11 PT Programming Manual 33 2 1 8 COS Programming 2 1 8 COS Programming 500 Trunk G
17. Manual 39 2 1 9 Extension Programming 627 Destination When All Busy gt gt Destination No gt gt 1 Day 2 Lunch Max 32 digits 3 Break 4 Night Incoming Call 627 gt gt Distribution ENTER Group No 001 128 lt lt 3 END ENTER 628 Queuing Call Capacity Incoming Call Distribution 628 gt lt ENTER Group No 001 128 629 Queuing Hurry up Level 629 gt gt ENTER Incoming Call Distribution Group No 001 128 630 Queuing Time Table Incoming Call 630 gt gt Distribution ENTER Group No 001 128 gt gt 4 3 END ENTER gt Number in Queuing gt gt 1 5 END Pe ENTER gt Hurry up Level J gt gt ZA END None 1 30 ENTER gt Table lt lt 1 Day 2 Lunch KX TDA50 None 01 64 3 Break 4 Night KX TDA100 None 01 64 KX TDA200 None 01 64 KX TDA600 001 128 631 Sequences in Queuing Time Table 631 gt gt Table No gt P K cp SELECT gt gt X TDA50 01 64 01 16 Overflow ENTER 100 01 64 Disconnect Ni 5 s KX TDA200 01 64 Sequence N OGM N KX TDA600 001 128 A number must be entered in place of the N END ENTER 40 PT Programming Manual Document Version 2008 11 2 1 9 Extension Programming 632 Maximum Number of Agents Incoming Call 632 gt er Distribution gt Numb
18. 01 gt gt gt Dei gt gt KI irmi END ENTER Confirming deleting operation To the Next Slot No To the Desired Slot No ENTER v CANCEL 902 Slot Card Reset 902 gt gt SlotNo gt Reset gt II Confirming the END ENTER resetting operation ENTER 910 OPB3 Option Card Type Reference KX TDA100 KX TDA200 KX TDA600 only 910 gt Slot No gt Card gt Option Card Type gt DI END ENTER 1 3 Reference only 911 OPB3 Option Card Deletion KX TDA100 KX TDA200 KX TDA600 only 911 gt gt Slot No gt Card No PI Card gt Delete gt Q gt CI Confirming the END ENTER deleting operation ENTER 48 PT Programming Manual Document Version 2008 11 Section 3 Appendix Document Version 2008 11 PT Programming Manual 49 3 1 4 KX TDA50 PSMPR Software File Version 5 0xxx 3 1 Revision History 3 1 1 KX TDA100 KX TDA200 PMPR Software File Version 3 2xxx Changed Contents 2 1 2 Maximum Values 007 DSS Console Paired Telephone 601 Terminal Device Assignment 3 1 2 KX TDA100 KX TDA200 PMPR Software File Version 5 0xxx Changed Contents 2 1 1 Programming Instructions 2 1 2 Maximum Values 2 1 9 Extension Programming 3 1 3 KX TDA50 PSMPR Software File Version 4 0xxx Changed Contents 2 1 1 Programming Instructions 2 1 2 Maximum Values 3 1 4 KX TDA50 PSMPR Softw
19. 16 1 1 SMDR Station Message Detail Recording Special Carrier Access Code 303 Special Carrier Access Code Feature Manual References 16 1 2 Special Carrier Access Code Speed Dialing System e 001 System Speed Dialing Number 002 System Speed Dialing Name 509 TRS Level for System Speed Dialing Feature Manual References 16 1 4 Speed Dialing System 62 PT Programming Manual Document Version 2008 11 3 2 Feature Programming References TAFAS Trunk Answer From Any Station 700 External Pager Floating Extension Number Feature Manual References 17 1 2 TAFAS Trunk Answer From Any Station Tenant Service 001 System Speed Dialing Number e 006 Operator Assignment 320 ARS Mode 711 Music on Hold Feature Manual References 17 1 3 Tenant Service Time Service 101 Time Service Switching Mode 102 Time Service Starting Time 514 Time Service Manual Switching Feature Manual References 17 1 5 Time Service TRS Toll Restriction 300 TRS Override by System Speed Dialing 301 TRS Denied Code 302 TRS Exception Code 501 TRS Level 509 TRS Level for System Speed Dialing 602 Class of Service Feature Manual References 17 1 6 TRS Toll Restriction Upgrading the Software 190 Main Processing MPR Software Version Reference Feature Manual References 18 1 1 Upgrading the Software Document Version 2008 11 PT Programming Manual 63
20. Emergency Number 304 gt gt Location No EmergencyNo gt EI END ENTER 01 10 Max 32 digits ENTER 320 ARS Mode Q gt gt eJ E gt 320 Offildle Line END ENTER All Access ENTER 321 ARS Leading Number 321 gt gt Location No lt Leading er igj END ENTER 0001 1000 Max 16 digits ENTER 322 ARS Routing Plan Table Number 322 gt gt Location No gt Pan TabeNo gt gt KI 0001 1000 KX TDA50 01 16 END ENTER KX TDA100 01 16 ENTER KX TDA200 01 16 KX TDA600 01 48 01 Document Version 2008 11 PT Programming Manual 27 2 1 6 TRS ARS Programming 325 ARS Exception Number 325 gt e gt Location No gt Exception No gt 9 gt E ENTER 001 200 Max 16 digits ENTER END 330 ARS Routing Plan Time Table 330 gt gt DayNo gt ARSTmeNo gt gt KX TDA50 01 16 0 Sun 1 Mon 2 Tue 1 TimeA 2 TimeB ENTER KX TDA100 01 16 Wed 4 Thu 5 Eug Sat 3 TimeC 4 TimeD KX TDA200 01 16 KX TDA600 01 48 Hour Minute gt gt DI lt lt 01 12 00 59 ENTER ii 331 346 ARS Routing Plan Table 1 16 KX TDA50 KX TDA100 KX TDA200 only 331 346 gt e gt gt 1 6 0 Sun 1 Mon 2 Tue 1 TimeA 2 TimeB ENTER 3 Wed 4 Thu 5 Fri 6 Sat 3 TimeC 4 TimeD bp Carrier Table No gt A 3 KX TDA50 01 10 None END
21. Extension to CO Line Call Duration 32 473 CO to CO Line Call Duration essen 32 475 DISA Silence Detection 33 476 DISA Continuous Signal Detection 33 477 DISA Cyclic Signal Detection E 33 490 Caller ID Signal 33 2 1 8 COS Progra mmihg MEER UT 34 500 Trunk Group N mber L U LL LL LEL LLE GRIL LL LL LL LL LL 34 501 TRS Level MY a Ad ASD 34 502 CO Line Call Duration Limitation 34 503 Call Transfer to CO Line 34 504 Call Forwarding to CO 34 505 Executive Busy Override YL HYF 35 506 Executive Busy Override Deny 4 35 507 DND Override a LL FD 35 508 Account Code Mod e diee nennen aan 35 509 TRS Level for System Speed Dialing 35 510 TRS Level for Extension Dial Lock 35 511 Manager Assignment FFF 35 512 Permission for Door Open Access 36 514 Time Service Manual Switching 36 515 Wireless Parallel Mode for Pai
22. IN gt 6 gt 0001 1000 Max 10 digits END ENTER ENTER CAUTION There is a risk that fraudulent telephone calls will be made if a third party discovers a personal identification number PIN verification code PIN or extension PIN of the PBX The cost of such calls will be billed to the owner renter of the PBX To protect the PBX from this kind of fraudulent use we strongly recommend a Keeping PINs secret b Selecting complex random PINs that cannot be easily guessed Changing PINs frequently 123 Verification Code COS Number 123 gt er Location gt COS No gt er 0001 1000 01 64 END ENTER 01 ENTER 190 Main Processing MPR Software Version Reference 190 gt gt E END ENTER Reference only 24 PT Programming Manual Document Version 2008 11 2 1 5 Timer Programming 2 1 5 Timer Programming 200 Hold Recall Time 200 gt e Time re a ENTER a ENTER HOLD 201 Transfer Recall Time 201 gt G gt Time gt gt DI END ENTER ENTER 203 Intercept Time 203 gt gt me gt Cine gt gt E 1 Day 2 Lunch 1 240 ENTER 3 Break 4 Night bios ENTER 204 Hot Line Waiting Time 204 gt gt Time rer ENTER 4 ENTER 0 205 Automatic Redial Repeat Times KX TDA100 KX TDA200 KX TDA600 only 205 gt gt mins gt gt E 0 10 END ENTER 0 207 Door Unlock Time 207 gt e Gm gt gt
23. NTER 800 RS 232C Parameter Parity Bit 800 gt er gt sur gt CQ gt MI 4 None Mark END ENTER Space Even Odd ENTER 800 RS 232C Parameter Stop Bit Length 800 gt er Location gt im gt 1 bit 2 bits END ENTER ENTER 801 External Modem Control 801 gt er Commando Kep gt END ENTER ENTER 802 SMDR Page Length 802 e Fan gt gt KI RE m END ENTER ENTER 803 SMDR Skip Perforation 803 gt gt Skip Perforation gt r EST END ENTER Mmes ENTER 46 PT Programming Manual Document Version 2008 11 2 1 12 Card Programming 804 SMDR Outgoing Call Printing 804 gt gt sc gt gt LJ No print END ENTER Print ENTER 805 SMDR Incoming Call Printing 805 gt Qu sc gt gt DI No print END ENTER Print ENTER 810 Remote Programming 810 gt gt CED 8 Disable END ENTER Enable ENTER 811 Modem Floating Extension Number 811 gt gt 599 ENTER 2 812 ISDN Remote Floating Extension Number KX TDA100 KX TDA200 KX TDA600 only 812 gt gt Exn No gt r OI END ENTER ENTER 2 1 12 Card Programming 900 Slot Card Type Reference 900 e gt ae gt CardName gt I Reference onl END ENTER x HOLD Document Version 2008 11 PT Programming Manual 47 2 1 12 Card Programming 901 Slot Card Deletion 9
24. Panasonic PT Programming Manual Hybrid IP PBX moderne KX TDASO KX TDA100 KX TDA200 KX TDAG600 Thank you for purchasing a Panasonic Hybrid IP PBX Please read this manual carefully before using this product and save this manual for future use KX TDA50 PSMPR Software File Version 5 0000 or later KX TDA100 KX TDA200 PMPR Software File Version 5 0000 or later KX TDA600 PLMPR Software File Version 5 0000 or later Document Version 2008 11 Introduction Introduction About this Programming Manual The PT Programming Manual is designed to serve as a reference to programming the Panasonic Hybrid IP PBX using a Panasonic proprietary telephone PT with display The PT Programming Manual is divided into the following sections Section 1 Overview Provides an overview of programming the PBX Section 2 PT Programming Serves as reference operating instructions when using a display PT to program the PBX Section 3 Appendix Provides a list of all related PT programming items for each feature as Feature Programming References References Found in the PT Programming Manual PT Programming Manual References Related sections of the PT Programming Manual are listed for your reference Feature Manual References The Feature Manual explains what the PBX can do as well as how to obtain the most of its many features and facilities Sections from the Feature Manual are listed throughout the PT Programming Manual for your reference
25. References 3 1 15 CO Line Call Limitation Dial Mode Selection 410 LCOT Dialing Mode 411 Pulse Rate 412 DTMF Minimum Duration Feature Manual References 4 1 2 Dial Mode Selection DID Direct Inward Dialing 451 DID Number 452 DID Name 453 DID Destination Feature Manual References 4 1 5 DID Direct Inward Dialing DIL Direct In Line e 450 DIL 1 1 Destination Document Version 2008 11 PT Programming Manual 53 3 2 Feature Programming References Feature Manual References 4 1 6 DIL Direct In Line DISA Direct Inward System Access 209 DISA Delayed Answer Time 210 DISA CO to CO Line Call Prolong Time 211 DISA Intercept Time 475 DISA Silence Detection 476 DISA Continuous Signal Detection 477 DISA Cyclic Signal Detection 604 Extension Intercept Destination 730 Outgoing Message OGM Floating Extension Number 731 Outgoing Message OGM Name 732 DISA Security Mode Feature Manual References 4 1 7 DISA Direct Inward System Access DND Do Not Disturb 507 DND Override Feature Manual References 4 1 9 DND Do Not Disturb Door Open 207 Door Unlock Time 512 Permission for Door Open Access Feature Manual References 4 1 10 Door Open Doorphone Call 720 Doorphone Call Destination 729 Doorphone Number Reference Feature Manual References 4 1 11 Doorphone Call EFA External Feature A
26. TER 051 400 ms 414 LCOT CPC Signal Detection Time lncoming 414 gt e Slot No gt PortNo gt gt er CI 0 None 1 6 5 END ENTER 2 113 N 1 x8ms ENTER 051 400 ms 416 LCOT Pause Time 416 gt gt Sal Pais gt em gt 2 1 5 2 5 END ENTER 3545s ENTER 417 LCOT Flash Recall Time 417 gt amp gt gt gt I N Seu END one ENTER 300 4 600 900 ENTER 1200 ms option 418 LCOT Disconnect Time 418 gt er SlotNo gt ED er 0 5 1 5 2 0 END ENTER 4 0 12 0 s ENTER 450 DIL 1 1 Destination 450 gt gt gt gt Destination No lt lt 1 Day 2 Lunch 1 5 digits ENTER 3 Break 4 Night gt gt EH END ENTER Document Version 2008 11 PT Programming Manual 31 2 1 7 CO Line Programming 451 DID Number 451 gt gt Lesson gt DDNG gt gt E END 0001 1000 Max 32 digits ENTER ENTER 452 DID Name 452 gt e gt LocationNo gt Name gt gt OI END ENTER 0001 1000 Max 20 characters ENTER 453 DID Destination 453 gt e gt Time No lt Location No gt Destination gt e 1 1 Day 2 Lunch we END ENTER 3 Break 4 Night 000171000 1 5 digits SS 471 Host PBX Access Code 471 gt gt FrunkGroupNa gt LomtonNe gt gt KX TDA50 01 64 01 10 ENTER KX TDA100 01 64 KX TDA200 01 64
27. Time Service Starting Time 102 gt gt Dale gt memo gt ENTER 0 Sun 1 Mon 1 Day 1 2 Lunch 2 Tue 3 Wed 3 Day 2 4 Night 4 Thu 5 Fri 6 Sat gt 01 00 12 59 AM PM ENTER To the Next Time No To the Next Day No ENTER v PJ NEXT Page up 103 Idle Line Access Local Access 103 gt gt Location gt Trunk Group No gt gt gt DI ENTER KX TDA50 01 64 END KX TDA50 01 64 KX TDA100 01 64 KX TDA100 01 64 ENTER KX TDA200 01 64 KX TDA200 01 64 KX TDA600 01 96 KX TDA600 01 96 Location No Trunk Group No 110 System Password for Administrator for PT Programming 110 gt gt 99 gt KI END 4 10 digits ENTER 1234 ENTER 111 System Password for User for PT Programming 111 gt gt Password gt gt DI END 4 10 digits ENTER 1234 ENTER 112 Manager Password 112 gt e Password gt er CO END 4 10 digits ENTER 91234 ENTER Document Version 2008 11 PT Programming Manual 23 2 1 4 System Management Programming 120 Verification Code 120 gt e gt gt Verification Code gt e gt DI 0001 1000 1 4 digits END ENTER ENTER 121 Verification Code Name 121 gt gt Daioni Nam gt gt KI 0001 1000 Max 20 characters END ENTER ENTER 122 Verification Code Personal Identification Number PIN 122 gt e Location No gt P
28. are File Version 5 0xxx Changed Contents 2 1 1 Programming Instructions 2 1 5 Timer Programming 451 DID Number 452 DID Name 453 DID Destination 2 1 8 COS Programming 2 1 10 Resource Interface Programming 50 PT Programming Manual Document Version 2008 11 3 2 Feature Programming References 3 2 Feature Programming References Absent Message 008 Absent Message Feature Manual References 1 1 1 Absent Message Account Code Entry 508 Account Code Mode Feature Manual References 1 1 2 Account Code Entry ARS Automatic Route Selection 320 ARS Mode 321 ARS Leading Number 322 ARS Routing Plan Table Number 325 ARS Exception Number 330 ARS Routing Plan Time Table e 331 346 ARS Routing Plan Table 1 16 KX TDA50 KX TDA100 KX TDA200 only 347 ARS Routing Plan Table 1 48 KX TDA600 only 350 ARS Carrier Name 351 ARS Trunk Group for Carrier Access 352 ARS Removed Number of Digits for Carrier Access 353 ARS Carrier Access Code Feature Manual References 1 1 3 ARS Automatic Route Selection Call Hold e 200 Hold Recall Time Feature Manual References 3 1 2 Call Hold Call Pickup 650 Extension User Groups of a Pickup Group Feature Manual References 3 1 6 Call Pickup Document Version 2008 11 PT Programming Manual 51 3 2 Feature Programming References Call Transfer 201 Transfer Recall Time e 503 Call Tran
29. ax 32 digits END ENTER KX TDA100 01 10 ENTER KX TDA200 01 10 KX TDA600 01 48 2 1 7 CO Line Programming 400 LCOT CO Line Connection 400 gt amp gt SitNo PorNo gt ES gt AUTO SET URN END ENTER No Connect ENTER HOLD Connect To the Next Port No To the Desired Port No ENTER NEXT CANCEL Document Version 2008 11 PT Programming Manual 29 2 1 7 CO Line Programming 401 LCOT CO Line Name 14011 lt CoLineno gt Name gt CI iai END ENTER 3 digits Max 20 characters ENTER 402 LCOT Trunk Group Number 402 gt er CO Line gt Trunk Group No gt am 3 digits KX TDA50 01 64 ENTER KX TDA100 01 64 ENTER KX TDA200 01 64 KX TDA600 01 96 01 409 LCOT CO Line Number Reference 409 gt e gt Slot NoJJ gt gt gum Reference only END ENTER 410 LCOT Dialing Mode 410 gt gt Sot NoJ gt SP gt I END ENTER DTMF Pulse ENTER 411 LCOT Pulse Rate 411 gt e gt Slot No lt PortNo SD gt I Low High END ENTER ENTER 412 LCOT DTMF Minimum Duration 412 egal Trail ene I ENTER MM m ENTER 30 PT Programming Manual Document Version 2008 11 2 1 7 CO Line Programming 413 LCOT CPC Signal Detection Time Outgoing 413 gt gt Soria Forth gt Modena gt EDI END 0 None 1 6 5 ENTER 2 113 N 1 x8 ms EN
30. ccess 417 LCOT Flash Recall Time 54 PT Programming Manual Document Version 2008 11 3 2 Feature Programming References Feature Manual References 5 1 1 EFA External Feature Access Emergency Call 304 Emergency Number Feature Manual References 5 1 2 Emergency Call Executive Busy Override 505 Executive Busy Override 506 Executive Busy Override Deny Feature Manual References 5 1 3 Executive Busy Override Extension Dial Lock 510 TRS Level for Extension Dial Lock Feature Manual References 5 1 4 Extension Dial Lock Extension PIN Personal Identification Number 005 Extension Personal Identification Number PIN Feature Manual References 5 1 6 Extension PIN Personal Identification Number Extension Port Configuration 007 DSS Console Paired Telephone 600 EXtra Device Port Mode Feature Manual References 5 1 7 Extension Port Configuration Flash Recall Terminate e 418 Disconnect Time Document Version 2008 11 PT Programming Manual 55 3 2 Feature Programming References Feature Manual References 6 1 2 Flash Recall Terminate Flexible Numbering Fixed Numbering e 100 Flexible Numbering Feature Manual References 6 1 4 Flexible Numbering Fixed Numbering Floating Extension 623 Incoming Call Distribution Group Name 660 VM Group Floating Extension Number 700 External Pager Floating Extension Number 730 Outgoing Message
31. er essen 27 325 ARS Exception 28 330 ARS Routing Plan Time Table 00 28 331 346 ARS Routing Plan Table 1 16 KX TDA50 KX TDA100 KX TDA200 OMY e t a aaa TS 28 347 ARS Routing Plan Table 1 48 KX TDA600 only 28 350 ARS Carrier a 29 351 ARS Trunk Group for Carrier Access 29 352 ARS Removed Number of Digits for Carrier Access 29 353 ARS Carrier Access 29 2 1 7 CO Line Programming 29 400 LCOT CO Line Connection 29 401 CO Line Name kennen anhand 30 402 Trunk Group Number 30 409 CO Line Number Reference 30 440 LCOT Dialing ModE E 30 411 Pulse EE 30 412 DTMF Minimum Duration 30 413 CPC Signal Detection Time Outgoing 31 414 CPC Signal Detection Time Incoming 31 416 Pause Time a a nennen nennen nnne nns 31 417 LCOT FlasniRaeall Time aan an 31 418 Disconnect Time 31 450 DIL 1 1 Destination nn anne 31 451 DID Een 32 PP 32 453 DID Destination 32 471 Host PBX Access Code 32 472
32. er of Agents G gt EZ ENTER Group No No Limitation 01 32 ENTER 001 128 640 Extension User Groups of a Paging Group 640 gt gt PagingGroupNo Extn User Group No lt lt ENTER KX TDA50 01 32 KX TDA50 001 032 KX TDA100 01 32 KX TDA100 001 032 KX TDA200 01 32 KX TDA200 001 032 KX TDA600 01 96 KX TDA600 001 096 SELECT 3 No Yes ENTER KX TDA50 KX TDA100 KX TDA200 Paging Group No 01 31 Extn User Group No 001 031 Paging Group No 32 All extension user groups KX TDA600 Paging Group No Extn User Group No 641 External Pagers of a Paging Group 641 gt gt Paging Group No lt External Pager No gt CD pp KX TDA50 01 32 KX TDA50 1 Nol Yes ENTER KX TDA100 01 32 KX TDA100 1 2 KX TDA200 01 32 KX TDA200 1 2 KX TDA600 01 96 KX TDA600 1 2 gt 3 END ENTER 650 Extension User Groups of a Pickup Group 650 gt gt Pickup Group Extn User Group No rr ENTER KX TDA50 01 64 KX TDA50 001 032 KX TDA100 01 64 KX TDA100 001 032 KX TDA200 01 64 KX TDA200 001 032 KX TDA600 01 96 KX TDA600 001 096 ep kt CB gt 9 gt 4 No Yes ENTER END KX TDA50 KX TDA100 KX TDA200 Pickup Group No 01 32 Extn User Group No 001 032 Pickup Group No 33 64 All extension user groups KX TDA600 Pickup Group No Extn User Group No Document Version 2008 11 PT Programming Manual 41 2 1 9 Extension Programming
33. erences nnna 51 Document Version 2008 11 PT Programming Manual 7 Table of Contents 8 PT Programming Manual Document Version 2008 11 Section 1 Overview This section provides an overview of programming the PBX Document Version 2008 11 PT Programming Manual 9 1 1 1 Introduction 1 1 Introduction 1 1 1 Introduction These programming instructions are designed to serve as an overall system programming reference for the Panasonic Hybrid IP PBX Each feature in the PBX has default settings that can be changed to customize the PBX to your requirements These settings control the functions of the PBX and changing them is referred to as system programming Only one person can perform system programming at a time Any other users trying to enter system programming mode will be denied access Ways to Program There are two programming methods PC Personal Computer Programming All features and settings of the PBX can be programmed through PC programming with Maintenance Console Installing and starting Maintenance Console are explained in the Installation Manual PT Proprietary Telephone Programming A subset of the features and settings of the PBX can be programmed using a PT PT programming is described in Section 2 1 PT Programming An extension user can perform system programming by entering three digit programming numbers with a PT 10 PT Programming Manual Document Vers
34. iffer these differences are listed within the programming item as shown in the example below 351 gt Carrier Table No Trunk Group No EZB gt O gt gt Disable END KX TDA50 01 10 KX TDA50 01 64 ENTER KX TDA100 01 10 KX TDA100 01 64 Enable ENTER KX TDA200 01 10 KX TDA200 01 64 KX TDA600 01 48 KX TDA600 01 96 These values vary by PBX model However please note that extension number slot and port entry values are not listed within each programming item These values vary depending on the model of PBX and the card type installed as shown below Extension Numbers All models 1 5 digits Feature Numbers All models 1 4 digits KX TDA50 Slot and Port Values Available Slot Entry Values Slot Number Supported Cards 01 Pre installed Super Hybrid Ports 02 04 DLC4 HLC4 PLC4 LCOT4 cards 18 PT Programming Manual Document Version 2008 11 2 1 2 Maximum Values Slot Number Supported Cards 05 07 DLC8 PLC8 SLC8 cards 08 09 card Enter slot numbers as two digit numbers e g 04 for slot 4 Available Port Entry Values Card Type Port Number Related Programming DLC4 01 04 HLC4 01 04 PLC4 01 04 600 601 DLC8 01 08 PLC8 01 08 DPH4 01 04 72x LCOT4 01 04 40x 41x 450 Pre installed Super Hybrid Ports 01 04 600 601 Enter values as two digit numbe
35. imited settings as permitted through PC programming 8 System Password for User O di id for PT Programming 4 PROGRAM PAUSE Programming No 1234 3 digits Note means default value throughout this manual Programming Structure Programming i M N mber Programming Group Title Description OXX Basic Programming Frequently used programming steps System Management Global system parameters 1XX 4 Programming 2XX Timer Programming System timers Document Version 2008 11 PT Programming Manual 17 2 1 2 Maximum Values Programming a Number Programming Group Title Description 3XX TRS ARS Programming TRS and Automatic Route Selection ARS programming 4XX CO Line Programming CO line and trunk group settings 5XX COS Programming Class of Service parameters 6XX Extension Programming Extension feature settings 7XX Resource Interface Programming PBX interface and external device settings 8XX SMDR amp Maintenance Station Message Detail Recording SMDR and Programming maintenance feature settings Card Programming Used to display the cards currently installed in the 9XX PBX or to delete a card from system programming before physically removing it 2 1 2 Maximum Values Throughout this manual maximum entry values are shown for each programming item When maximum entry values for one or more of the supported PBX models d
36. ion 2008 11 1 1 2 Password Security 1 1 2 Password Security To maintain system security system passwords are required to access certain programming functions of the PBX By giving different users access to different passwords it is possible to control the amount of programming that each user is able to perform The following types of system passwords are available Password Description Format System Password PT for Used to access user level PT programming The specific PT 4 10 digits User programming items that may be programmed at user level can be selected through system programming System Password PT for Used to access administrator level PT programming All PT Administrator programming settings are available CAUTION To the Administrator or Installer regarding the system password 1 Please provide all system passwords to the customer 2 To avoid unauthorized access and possible abuse of the PBX keep the passwords secret and inform the customer of the importance of the passwords and the possible dangers if they become known to others 3 The PBX has default passwords preset For security change these passwords the first time that you program the PBX 4 Change the passwords periodically 5 Itis strongly recommended that passwords of 10 numbers or characters be used for maximum protection against unauthorized access For a list of numbers and characters that can be used in system
37. lotNo gt PortNo rer END ENTER See below ENTER KX TDA50 KX TDA100 KX TDA200 KX TDA600 Telephone Telephone Telephone DSS Console 01 04 055 Console 01 08 DSS Console 01 64 Voice Mail 1 01 04 Voice Mail 1 01 12 Voice Mail 1 8 01 12 PC Console 1 2 Voice Mail 2 01 12 PC Console 1 8 PC Console 1 8 Note When changing the type of a port for which one or more SDN buttons are set except when changing between PC Console and Telephone all SDN buttons customized for that device will be deleted KX TDA100 KX TDA200 KX TDA600 only 602 Class of Service 602 gt e Emm gt 65 gt gt I E END ENTER 2 ENTER 603 Extension User Group 603 e gt E No Extn User Group No e E KX TDA50 001 032 END ENTER KX TDA100 001 032 ENTER KX TDA200 001 032 KX TDA600 001 096 001 Document Version 2008 11 PT Programming Manual 37 2 1 9 Extension Programming 604 Extension Intercept Destination 604 gt amp gt Time Extn No gt Destination No gt CI 1 Day 2 Lunch ENTER Break 4 Night Max 32 digits END ENTER 605 Call Forwarding No Answer Time 605 gt gt Emm im gt ENTER 606 CLIP Number gt END ENTER 606 gt gt Eine gt gt CC ENTER Max 16 digits END ENTER 620 Incoming Call Distribution Group Member Incoming Call 620 gt Q
38. ng References Paging 640 Extension User Groups of a Paging Group 641 External Pagers of a Paging Group Feature Manual References 13 1 1 Paging Paralleled Telephone 600 Extra Device Port Mode Feature Manual References 13 1 2 Paralleled Telephone Pause Insertion 416 LCOT Pause Time Feature Manual References 13 1 4 Pause Insertion PC Console PC Phone 601 Terminal Device Assignment Feature Manual References 13 1 5 PC Console PC Phone Private Network Features 453 DID Destination e 500 Trunk Group Number Feature Manual References 13 1 13 PRIVATE NETWORK FEATURES Private Network Features NDSS Network Direct Station Selection 511 Manager Assignment Feature Manual References 13 1 15 Private Network Features NDSS Network Direct Station Selection 60 PT Programming Manual Document Version 2008 11 3 2 Feature Programming References Private Network Features PS Roaming by Network ICD Group 620 Incoming Call Distribution Group Member 622 Incoming Call Distribution Group Floating Extension Number 624 Incoming Call Distribution Group Distribution Method Feature Manual References 13 1 17 Private Network Features PS Roaming by Network ICD Group Private Network Features QSIG CLIP COLP Calling Connected Line Identification Presentation and CNIP CONP Calling Connected Name Identification Presentation 003 Extension Number 004
39. o gt PortNo gt gt 1 4 1 Day 2 Lunch ENTER 3 Break 4 Night lt lt Destination gt r iai END Max 32 digits ENTER 44 PT Programming Manual Document Version 2008 11 2 1 11 SMDR amp Maintenance Programming 729 Doorphone Number Reference KX TDA100 KX TDA200 KX TDA600 729 gt e Si Gard No and Por No Doorphone No gt CI ENTER 1 3 1 4 Reference only END KX TDA50 729 gt e gt 59 gt gt DoorphoneNo gt ZJ Reference only END ENTER 730 Outgoing Message OGM Floating Extension Number 730 gt gt Message No gt Exn No gt r CI ENTER 01 64 501 564 ENTER END 731 Outgoing Message OGM Name 731 gt gt esch gt Name gt O gt I END ENTER 01 64 Max 20 characters ENTER 732 DISA Security Mode 732 6 gt 3 None END ENTER CO Line All ENTER 2 1 11 SMDR amp Maintenance Programming 800 RS 232C Parameter New Line Code 800 gt Location gt xc gt AUTO ANS MESSAGE END ENTER CR LF CR ENTER HOLD Document Version 2008 11 PT Programming Manual 45 2 1 11 SMDR amp Maintenance Programming 800 RS 232C Parameter Baud Rate 800 gt e gt Location gt S gt e gt F 2 2400 4800 9600 END ENTER 19200 38400 57600 ENTER 800 RS 232C Parameter Word Length 800 gt er gt ser gt CQ gt 3 71 8 bits END ENTER E
40. of Agents Feature Manual References 9 1 1 ICD GROUP FEATURES ICD Group Features Group Call Distribution 621 Incoming Call Distribution Group Delayed Ringing 624 Incoming Call Distribution Group Distribution Method 632 Maximum Number of Agents Feature Manual References 9 1 2 ICD Group Features Group Call Distribution ICD Group Features Outside Destinations 620 Incoming Call Distribution Group Member 621 Incoming Call Distribution Group Delayed Ringing 622 Incoming Call Distribution Group Floating Extension Number 624 Incoming Call Distribution Group Distribution Method 629 Queuing Hurry up Level Feature Manual References 9 1 4 ICD Group Features Outside Destinations ICD Group Features Overflow 625 Destination for Overflow Time Expiration 626 Overflow Time 627 Destination When All Busy Document Version 2008 11 PT Programming Manual 57 3 2 Feature Programming References 628 Queuing Call Capacity 632 Maximum Number of Agents Feature Manual References 9 1 5 ICD Group Features Overflow ICD Group Features Queuing 628 Queuing Call Capacity 629 Queuing Hurry up Level 630 Queuing Time Table 631 Sequences Queuing Time Table 632 Maximum Number of Agents Feature Manual References 9 1 6 ICD Group Features Queuing Idle Extension Hunting 680 Idle Extension Hunting Type 691 Idle Extension Hun
41. onsult your certified Panasonic dealer for more information Product specifications are subject to change without notice ln this manual model number suffixes e g KX TDA50G are omitted unless necessary Document Version 2008 11 PT Programming Manual 3 Table of Contents Table of Contents 4 1 9 1 1 Introduction 10 1 1 1 10 1 1 2 Password FWY TPN Hr 11 1 1 3 Entenng GharacterS Lande 12 2 PT Programming anne 15 2 1 PT Programming meer 16 2 1 1 Programming Instructions RP 16 2 1 2 18 2 1 3 BasiG Progr mMINg enn 20 000 Date as us sas a ER 20 001 System Speed Dialing Number 20 002 System Speed Dialing 20 003 Extension 21 004 Extension 21 005 Extension Personal Identification Number 21 006 Operator Assignment 21 007 DSS Console Paired Telephone 21 008 Absent Message 22 2 1 4 System Management Programming 22 100 Flexible 22 101 Time Service Switching Mode nn 22 102 Time Service Starting Time 23 103 Idle Line Access Local Access 23 110 System Password for Administrator for PT Programming
42. passwords refer to Section 1 1 3 Entering Characters 6 Ifa system password is forgotten it can be found by loading a backup of the system data into a PC and checking the password using the Maintenance Console software If you do not have a backup of the system data you must reset the PBX to its factory defaults and reprogram it Therefore we strongly recommend maintaining a backup of the system data For more information on how to back up the system data refer to the on line help of the Maintenance Console However as system passwords can be extracted from backup copies of the system data file do not allow unauthorized access to these files Document Version 2008 11 PT Programming Manual 11 1 1 3 Entering Characters 1 1 3 Entering Characters The following characters can be used when storing a name message or other text entry data using a PT The tables below show you the characters available by pushing each button a specific number of times Table 1 Standard mode 12 PT Programming Manual Document Version 2008 11 1 1 3 Entering Characters Example of Entering Characters To enter Ann FWD DND 2 6 5 times op gt 6 5times erase the character on the cursor press CLEAR To move the cursor to the left press lt a To move the cursor to the right press mi When entering two or more characters that use the same button consecutively e g and I
43. r internal use only All other reproduction in whole or in part is prohibited without the written consent of Panasonic Communications Co Ltd Panasonic Communications Co Ltd 2006 PSQX3823VA KK0206ET4118
44. red Telephone 6 36 516 Programming Mode Limitation n 36 2 1 9 Extension Programming totus 37 600 Extra Device Port XDP rege tette aa 37 601 Terminal Device Assignment 37 Document Version 2008 11 PT Programming Manual 5 Table of Contents 6021 Glass ee 37 603 Extension User Group 37 604 Extension Intercept Destination 38 605 Call Forwarding No Answer Time FF nn nno 38 isis Ee BEI TE tct rc 38 620 Incoming Call Distribution Group Member 38 621 Incoming Call Distribution Group Delayed Ringing 38 622 Incoming Call Distribution Group Floating Extension Number 39 623 Incoming Call Distribution Group esee 39 624 Incoming Call Distribution Group Distribution Method 39 625 Destination for Overflow Time Expiration 39 626 Overflow Time 39 627 Destination When All Bus 40 628 Queuing Call Capacity EN 40 629 Queuing Hurry up Level ER 40 630 QUEUING Time Table 7 40 631 Sequences in Queuing Time Table 40 632 Maximum Number of Agents 41 640 Extension User Groups of a Paging Group 41 641 Exte
45. rnal Pagers of a Paging 41 650 Extension User Groups of a Pickup Group nennen 41 660 VM Group Floating Extension Number 42 680 Idle Extension Hunting Type nennen 42 681 Idle Extension Hunting Group Member 42 690 PS Registration nennen nnns 42 691 PS Termination 0 43 692 Personal Identification Number PIN for PS Registration 43 699 CS Status Reference 43 2 1 10 Resource Interface Programming 43 700 External Pager Floating Extension Number 43 710 Music Source Selection for BGM with the KX TDA50 BGM2 with the KX TDA100 KX TDA200 KX TDA600 44 ATT MUSIC Hold 44 712 Music for Transfer 44 720 Doorphone Call Destination 44 729 Doorphone Number Reference 45 730 Outgoing Message OGM Floating Extension Number 45 731 Outgoing Message OGM 45 732 DISA Security Mode 45 2 1 11 amp Maintenance Programming 45 800 RS 232C Parameter New Line Code 45 800 RS 232C Parameter Baud Rate nenn 46 800 RS 232C Parameter Word Length
46. roup Number 500 gt gt TimeNo gt gt 1 Day 2 Lunch 01 64 ENTER 3 Break 4 Night lt lt Trunk Group gt SELECT gt AUTO ANS MESSAGE END KX TDA50 01 64 KX TDA100 01 64 Disable Enable ENTER HOLD KX TDA200 01 64 KX TDA600 01 96 To tne Next TO the Next Trunk Group COS No No ENTER Y 501 TRS Level 501 gt gt Time gt COS gt Level gt r END 1 Day 2 Lunch 01 64 1 7 ENTER 3 Break 4 Night ENTER 502 CO Line Call Duration Limitation 502 gt e gt gt er 01 64 END ENTER T ENTER 503 Call Transfer to CO Line 503 gt 05 gt gt E 01 64 Disable ENTER Enable ENTER 504 Call Forwarding to CO Line 504 gt COSNo gt gt DI END 01 64 Disable ENTER Enable ENTER 34 PT Programming Manual Document Version 2008 11 2 1 8 COS Programming 505 Executive Busy Override 505 gt cosno gt EP rer END Disable ENTER ms Enable ENTER 506 Executive Busy Override Deny 506 gt gt COSNo gt Sn gt O gt EI END 01 64 Disable Enable ENTER 507 DND Override 507 gt cosNo gt rer END 01 64 Disable Enable ENTER 508 Account Code Mode 508 gt er costo gt amp gt EI 01 64 Option END ENTER Forced ENTER
47. rs e g 04 for port 4 KX TDA100 KX TDA200 KX TDA600 Slot and Port Values Available Slot Entry Values KX TDA100 KX TDA200 PBX Model Slot Number Supported Cards KX TDA100 01 06 All cards KX TDA200 01 11 Enter slot numbers as two digit numbers e g 04 for slot 4 KX TDA600 Slot Number Supported Cards 101 110 201 211 301 311 401 411 All cards Enter slot numbers as three digit numbers of the form XYY X Shelf number 1 4 YY Slot number 01 11 Document Version 2008 11 PT Programming Manual 19 2 1 3 Basic Programming Available Port Entry Values Card Type Port Number Related Programming DHLC8 01 08 DLC8 01 08 600 601 DLC16 01 16 DPH4 11 34 72x LCOT8 KX TDA100 KX TDA200 01 08 400 409 41x 450 only LCOT16 KX TDA100 01 16 KX TDA200 only ELCOT16 KX TDA600 only 01 16 Enter values as two digit numbers e g 04 for port 4 Enter card number and port number as single digit numbers e g 34 for card 3 port 4 2 1 3 Basic Programming 000 Date amp Time 000 gt gt Ge gt von gt Dae gt lt lt B 01 31 ENTER Ss ER ENTER gt gt CO gt gt Minute gt CD gt gt D 01 12 00 59 AUTO ANS MESSAGE END ENTER HOLD 001 System Speed Dialing Number 001 9 gt Speed baling No gt Telephone No gt gy
48. sfer to CO Line 712 Music for Transfer Feature Manual References 3 1 8 Call Transfer Caller ID 001 System Speed Dialing Number 002 System Speed Dialing Name 490 Caller ID Signal Type Feature Manual References 3 1 1 Caller ID CLI Calling Line Identification Distribution e 001 System Speed Dialing Number 002 System Speed Dialing Name Feature Manual References 3 1 12 CLI Calling Line Identification Distribution CLIP Calling Line Identification Presentation 003 Extension Number 606 CLIP Number Feature Manual References 3 1 13 CLIP Calling Line Identification Presentation COS Class of Service 2 1 8 COS Programming 602 Class of Service Feature Manual References 3 1 19 COS Class of Service CPC Calling Party Control Signal Detection 413 LCOT CPC Signal Detection Time Outgoing 414 LCOT CPC Signal Detection Time lncoming 52 PT Programming Manual Document Version 2008 11 3 2 Feature Programming References Feature Manual References 3 1 20 CPC Calling Party Control Signal Detection CO Line Access 400 LCOT CO Line Connection 401 LCOT CO Line Name 409 CO Line Number Reference 500 Trunk Group Number Feature Manual References 3 1 14 CO Line Access CO Line Call Limitation 472 Extension to CO Line Call Duration 473 CO to CO Line Call Duration 502 CO Line Call Duration Limitation Feature Manual
49. t Timeno gt Extn No er 1 Day 2 Lunch 101 END ENTER 3 Break 4 Night ENTER 007 DSS Console Paired Telephone 007 gt gt DsSConsoleNo gt gt gt KI KX TDA50 01 04 END ENTER KX TDA100 01 08 ENTER KX TDA200 01 08 KX TDA600 01 64 Document Version 2008 11 PT Programming Manual 21 2 1 4 System Management Programming Note This program is only available after the port connected to the DSS Console is assigned as DSS Console in 601 Terminal Device Assignment If one or more SDN buttons have been set at the DSS Console they must be deleted before this setting can be changed KX TDA100 KX TDA200 KX TDA600 only 008 Absent Message 008 gt gt Loes onNo gt Wege gt gt I 1 8 16 characters END ENTER ENTER For default values see 1 1 1 Absent Message in the Feature Manual 2 1 4 System Management Programming 100 Flexible Numbering 100 gt gt LocationNo gt FestusNo gt gt EI 01 68 END ENTER ENTER HOLD To the Next Location No To the Desired Location No v NEXT CANCEL For default values see 6 1 4 Flexible Numbering Fixed Numbering in the Feature Manual 101 Time Service Switching Mode CD 101 gt gt s gt gt CO AUTO ANS MESSAGE END ENTER Manual Automatic ENTER 22 PT Programming Manual Document Version 2008 11 2 1 4 System Management Programming 102
50. ting Group Member Feature Manual References 9 1 9 Idle Extension Hunting Intercept Routing 203 Intercept Time 604 Extension Intercept Destination 625 Destination for Overflow Time Expiration Feature Manual References 9 1 11 Intercept Routing Intercept Routing No Destination 006 Operator Assignment Feature Manual References 9 1 12 Intercept Routing No Destination Intercom Call 003 Extension Number e 004 Extension Name 58 PT Programming Manual Document Version 2008 11 3 2 Feature Programming References Feature Manual References 9 1 13 Intercom Call Line Preference Outgoing 103 Idle Line Access Local Access 500 Trunk Group Number Feature Manual References 10 1 3 Line Preference Outgoing Manager Features 112 Manager Password 511 Manager Assignment Feature Manual References 11 1 1 Manager Features Music on Hold e 710 Music Source Selection for BGM with the KX TDA50 BGM2 with the KX TDA100 KX TDA200 KX TDA600 711 Music on Hold Feature Manual References 11 1 4 Music on Hold OGM Outgoing Message 631 Sequences in Queuing Time Table 730 Outgoing Message OGM Floating Extension Number Feature Manual References 12 1 2 OGM Outgoing Message Operator Features e 006 Operator Assignment Feature Manual References 12 1 5 Operator Features Document Version 2008 11 PT Programming Manual 59 3 2 Feature Programmi

Download Pdf Manuals

image

Related Search

Related Contents

  BBox-single port PoE Hub.qxd  Yamaha ACU16-C Owner's Manual  Sony Mavica CD 350 complete manual  Microsoft OLE DB-Anbieter für DB2  Android TV Box - Sunsky  Allgemeine Anwendungshinweise für Lautsprecher  Estudio de herramientas para la gestión de repositorios digitales  

Copyright © All rights reserved.
Failed to retrieve file