Operations & Service Manual
Contents
1. Bead of Hi Temp Fit Rear Skirt inside flanges of Silicone Side Skirts 21 1 4 20 Nut Rear Skirt Left Skirt Right Skirt Model FSH 5 amp FSH 6 Installation 2 04 Hood Stand Installation Stand Mount model BEAD OF HIGH TEMP SILICONE INCLUDED STEP 1 BEAD OF HIGH TEMP SILICONE INCLUDED BEAD OF HIGH TEMP SILICONE INCLUDED SCREW WASHER LEFT SIDE RIGHT SIDE REAR BOTTOM PANEL NOTE NO HOLES ON BOTTOM FLANGE STEP 2 STEP 3 REAR TOP PANEL SCREWS WASHER BEAD OF HIGH TEMP SILICONE INCLUDED APPLIANCE POSITIONING CHANNEL INSTALL BEFORE APPLIANCE IS PLACED UNDER HOOD APPLIANCE POSITIONING CHANNEL INSTALL AFTER APPLIANCE IS PLACED UNDER HOOD FASTEN FRONT LEGS TO FLOOR AS REQUIRED BY LOCAL CODE OR GENERAL CONTRACTOR Installation Model FSH 5 amp FSH 6 2 05 Cooking Appliance limitations and clearances 2 05 1 Fryer limitations Electric Appliances Only Max Max Cooking Cooking Hood Max Temp Max kW Input Shortening Surface per Surface Total Capacity Fryer all Fryers FSH 5 380 Sq In 760 Sq In 2 05 2 Fryer clearances side to side overhang clearance does not apply with Stand Mount model 14 MIN d 114 2895 60 Ceiling 117 3 16 2976 56 72 Stand 123 1 8 3127 38 78 Stand MIN CEILING HEIGHT 33 844 0 min 42 1066 8 max 15 1
2. z l EA E mm 40 5 8 B 1031 9 FRONT SIDE Model FSH 5 amp FSH 6 Introduction 1 4 Specifications 1 4 3 Regulatory Listings 1 4 4 Hood Weights Crated Weight Uncrated Weight 664 105 302 kg 464 105 211 kg 733 Ibs 333 kg 553 Ibs 251 kg Installation Model FSH 5 amp FSH 6 2 Installation This section summarizes the procedures necessary to install your new FSH 5 or FSH 6 Hood Before installing or servicing this equipment please read the contents of this manual thoroughly Following these procedures will help ensure a safe and proper installation NOTE e A HVAC specialist may be required for some installations to confirm proper air exchange and the heat load capabilities of the on site AC system Exhaust ventilation is recommended for areas in which recirculating hoods are used We recommend 50 per linear ft of hood This amount could vary based on local codes and the site specific installation requirements 2 01 Unpacking Your Ventless Hood should arrive palletized with a wooden protective frame wrapped in machine applied stretch wrap and secured by means of high tensile plastic strapping Perform the following steps to unpack the unit 1 Position the palletized unit in an area that has sufficient space for unpacking IMPORTANT NOTE f the palletized unit shows any signs of damage immediately inspect the equipmen
3. A Maintenance and Service Log is provided in this manual see Table 5 6 5 1 Monthly Interlock Check The Giles Ventless Hood System is designed with various interlock devices to ensure the unit operates in a safe and effective manner These interlocks should be tested MONTHLY as described below Use the Maintenance amp Service Log and place a check in the box that corresponds to each function test If a problem is found call your service representative 1 Baffle Filter Check Place power switch in the OFF position remove the left side Baffle Filter turn power ON Filter Missing Light should be illuminated Check appliance power there should be none Turn power OFF and reinstall the Grease Baffle Filter Follow the same procedure to check the right side Filter 2 Pre Filter Door Interlock Check Turn power switch ON with Hood running slightly open the Filter Access door confirm Hood shutdown when door is opened turn power switch Remove the left side Pre Filter and close door turn power ON Filter Missing Light should be illuminated Check appliance power there should be none Turn power OFF and reinstall Pre Filter Follow the same procedure to check the right side Pre Filter 3 EAC Filter Check Place power switch in the OFF position remove the left side EAC Filter and close door turn power ON Wait 2 minutes intermittent alarm should sound Check appliance power there should none Tur
4. d Ansul P N 56811 og 2 073 Appliance Nozzles Center Nozzles over cooking surface s Appliance Nozzle 2 minimum Sized and Located by Local Authorized Fire Suppression Agency Supplied by Customer FRONT VIEW SIDE VIEW 16 Installation Model FSH 5 amp FSH 6 2 07 4 Fire Extinguisher Nozzle Locations Plenum Nozzle Factory installed Plenum Nozzle Appliance Nozzle 2 minimum Sized and Located by Local Plenum Nozzle Authorized Fire Suppression Fig A Factory installed Agency 79 i Supplied by Customer E Jf 2 075 General Maintenance The fire extinguishing system should be maintained as outlined in the Standard for Wet Chemical Extinguishing Systems NFPA 17A and in accordance with the instructions of the system s installer Please contact a local Authorized Fire Suppression Agent or Ansul Dealer for maintenance trouble shoot ing and repairs General Maintenance of the fire suppression system is very important Inspect and maintain as follows Servicing and inspection of the fire suppression system is to be conducted by qualified fire protection technicians As a minimum field inspection of the fire suppression system is to be performed semi annu ally Such maintenance shall consist of the following Confirm t
5. ERR RR EY REY ed 38 4 02 20 Ultra Violet Lamp Installation Ire 39 4 03 Filter Alami CMAN 3 2 ET 40 5 Hood Cleaning and Maintenance 41 5 1 Monthly Interlack COR s aad aj do we we eee aR 41 5 2 Quarterly Hood Cleaning eens 41 5 3 Semi Annual Fire Suppression System 42 5 4 Annual Fire Suppression SVSEOITI vou ea DE LORO BERS ooo beh EYE RE ES 42 5 5 12 Year Fire Suppression Syste ee uns ace eoa da owen X a K CR RE eae Ee qa OS RD ed 42 5 6 Maintenance and Service LOG exu set ee ck oe Ex oes Sh GERE RE XX 43 6 Troubleshooting 45 6 1 Troubleshooting 45 7 Parts List qr 47 7 1 Parts Ordering and Service uiri ea ia ra re 47 7 2 Component Drawer FSH 5 and FSH 6 48 7 3 Front View Doors and Panel 50 7 4 Baffle Filters and 5 52 7 5 Doors and Front Panel ses rale sace Re m pa sa d ss mau dus S doe d 54 7 6 Stand amp scs uana dese Sad REA S Ea
6. Filter days Clean every 30 days Section 4 02 19 Section 4 02 18 Section 4 02 20 Replace annually Ultra violet Lamp If equipped 27 Model 5 5 amp FSH 6 Operation amp Filter Maintenance 4 02 02 Baffle Filter Removal 28 Operation amp Filter Maintenance Model FSH 5 amp FSH 6 4 02 03 Baffle Filter Installation Front View Position Filter Baffles vertically Switch Arm must be actuated by the Baffle Filter as shown 4 02 04 Baffle Filter Missing If either Baffle Filter is missing or not in place correctly the Filter Missing Light will illuminate and power to cooking appliance is interrupted until the condition is corrected See Section 4 2 03 Baffle Filter Installation 29 Model 5 5 amp FSH 6 Operation amp Filter Maintenance 4 02 05 Baffle Filter Cleaning Grease Baffle Filters should cleaned daily Place in sink and clean with a mild bio degradable degreaser Dry thoroughly and reinstall in the unit 4 02 06 Pre Filter Removal 1 Place in OFF position Pre Filter Door open Aa aty OP Front View 30 Operation amp Filter Maintenance Model FSH 5 amp FSH 6 4 02 07 Pre Filter Installation Pre Filter Metal Mesh Side Door open e s LAICI Paper Side Pre Filter Switch Roller must be actuated by the Pre Filter as shown Front View o
7. ROCKER SWITCH ON OFF 250v 20A DST 9 23782 T SONALERT 250v CONTINUOUSTONE SSS UV Only ILS Only Not Shown 49 Model FSH 5 amp FSH 6 Parts List 7 3 Front View Doors and Panel removed 1 Not Shown 50 Parts List Model FSH 5 amp FSH 6 7 3 Parts List for Front View Doors and Panel removed 6 9026 2 UVLAMPASSEMBLY 16 IN REPLACEMENT ONLY x C Not Shown 51 Model FSH 5 amp FSH 6 Parts List 7 4 Baffle Filters and Switches ILS Only Not Shown 52 Parts List Model FSH 5 amp FSH 6 7 4 Parts List for Baffle Filters and Switches 1 42300 2 FILTER BAFFLE S S 20X20 2 3 6 1 DRPCUP I 3 32102 2 BAFFLE FILTER SWITCH ASSEMBLY 2 1 2 53 Model FSH 5 amp FSH 6 Parts List 7 5 Doors and Front Panel Ceiling Mounted Not Shown 54 Parts List Model FSH 5 amp FSH 6 7 5 Parts List for Doors and Front Panel Ceiling Mounted 2 33637 1 FILTERDOORASSEMBIYLET 3 46162 1 FIREDAMPER 4 33205 1 FANDUCTPANELASSEMBLY NON UVMODELONIY 90429 1 FANDUCTPANELASSEMBLY UV MODEL ONLY 5 4303 1 GUARD FIRE DAMPER O S y O 33253 1 FILTER DOOR ASSEMBLY RIGHT Y O eS S 8 9 31868 31885 BACK SPLASH PANEL FSH 6 Not shown 55 Model FSH 5 amp FSH 6 Parts List 7 6 Stand Mo
8. dots sp u Saa Qa Ba Eee a dG S O ace macau i a 4 1 4 4 Hood Weights 1 4 2 Installation avesti CC DU Ge ee eS 5 2 01 aere oo done dew me ya REQUE US quale hos be he REOR pus KR 5 2 02 Location y sana pay maqta imaqa EEG buy Esa edge med ede parties rats 6 2 03 Hood Mounting Detalle teen skua LEUR XU GU RUP RR CEU SUR OE cd 6 2 03 HOod SKirtInstallation a fsi AIME Ed PE EA 7 2 04 Hood Stand Installation ess sece tine d e ue RETE Y bed eee 8 2 05 Cooking Appliance limitations and clearances 9 2 05 1 Fryer limitations 9 2 05 2 Lye oi ted be thaw Uh yasa xeu woe Shu ya ties dte oa eee dis Mus kue 9 2 05 3 OVEN eens Powe e Ro eee tardes Reet eee dam u s d 10 2 05 4 OVenclearadlde8s ce ate Eie Sueos a 10 2 05 5 Griddle limitations aue en este mette see usse 11 2 05 6 Griddle cledraneesc s ooh uad bebe e 11 2 05 7 Range limitations ou e big er rr Bae dd edere bag dd deeds 12 2 05 8 Range ed pcs epa dead don d Rd n x WADE So SU 12 2 06 Hood Elec
9. height measured from floor to bottom edge of skirt UV Ultimate Ventless e Ultra violet lamp working in conjunction with Giles proven air filtration system further reduces exhaust emissions and improves odor control as well as keeping the unit s fan plenum and discharge duct free from grease build up Model FSH 5 amp FSH 6 Introduction 1 4 Specifications 1 4 1 Overall Dimensions for FSH 5 6 Ceiling Mount model DIM FSH 5 FSH 6 A 60 9 16 1538 3 72 9 16 1843 1 B 55 1 8 1400 2 C to C 67 1 8 1705 0 C to C C 59 15 16 1521 9 71 15 16 1705 0 49 5 6 1259 76 42 1 8 1970 52 15 1 8 383 65 69 1752 60 DISTANCE FROM FLOOR _ m INCHES MILLIMETERS FRONT VIEW SIDE VIEW Introduction Model FSH 5 amp FSH 6 1 4 Specifications 1 4 2 Overall Dimensions for FSH 5 6 Stand Mount model DIM FSH 5 FSH 6 A 60 9 16 1538 3 72 9 16 1843 1 B 56 7 16 1433 5 68 7 16 1738 3 C 61 3 4 1568 5 73 3 4 1873 3 with 72 Stand Mt with 78 Stand Mt D 72 1828 8 78 1981 2 E 117 3 16 2976 6 123 1 8 31274 INCHES MILLIMETERS 58 9 16 DOOR OPEN 1487 5 DOOR OPEN 7 49 5 8 Li 1260 5 42 1 4 1073 2 sf i del eat cadi A L Bl x E o
10. system Power Switch The Power Switch is a two position Switch Move the switch upward to the ON position for operation CHECK LED Indicator Right amp Left EAC s The Check Indicator Light will turn on when the EAC becomes shorted EAC needs cleaning or repair WASH LED Indicator Right amp Left EAC s The Wash Indicator Light will come on when the EAC becomes excessively dirty DO NOT use this light as a signal for routine cleaning of the EAC Failure to clean the EAC daily will significantly decrease the life of the charcoal filter and possibly damage the EAC power supply Clean the EAC daily for best performance ON LED Indicator Right amp Left EAC s The ON Indicator Light will turn on when the Electronic Air Cleaner EAC power supply is on Filter Missing Light nter Locking Start ILS Only The Filter Missing Light will turn on when the Grease Baffle Filter Pre Filter or Charcoal Filter are missing or are not prop erly positioned in the hood 21 Overview Model FSH 5 amp FSH 6 3 02 Filter Chamber and Exhaust 22 Overview Model FSH 5 amp FSH 6 3 02 Filter Chamber and Exhaust Item Description 2 Hood Filter Door Function Used to access the Pre Filter EAC and Charcoal Filters The door must be closed and latched for the unit to operate 2 Baffle Filter The Baffle Filters are the first stage of the g
11. 2 Ensure intended mounting site is structurally sound and capable of supporting the hood s weight See Section 1 4 4 for hood weights 2 03 Hood Ceiling Mounting Detail 1 2 All Thread Exhaust Air Outlet 1 2 Hex Nut 55 1 8 1400 15 CtoC 1 39 990 59 c CEILING 1 2 Lock Washer 1 2 Flat Washer 114 2895 60 MIN 1 2 Flat Washer 1 2 Lock Washer 1 2 Hex Nut FRONT VIEW SIDE 1 Ensure the hood 15 level left to right and front to back 2 Ensure all mounting fastening are secure 6 Installation Model FSH 5 amp FSH 6 2 03 Hood Skirt Installation NOTE Hood Skirts MUST be installed for correct air capture 1 2 5 6 Apply bead of Hi Temp Silicone included to the top flanges of both Side Skirts Attach Left and Right Side Skirts to hood with enclosed fasteners do not tighten completely Apply a bead of the Hi Temp Silicone to the top flange of the Rear Skirt Attach Rear Skirt to hood with enclosed fasteners do not tighten completely Fasten Left and Right Skirts to Rear Skirt Completely tighten all fasteners and wipe any excess silicone from the assembled Skirt NOTE Peel all protective film from parts before assembling Bead of Hi Temp Silicone 21 1 4 20 X 3 8 Screw Tube of Hi Temp Silicone is enclosed
12. 2 MIN 393 70 8 1 4 MIN 209 55 0 when using stand option 8 1 4 MIN 209 55 0 when using stand option FRONT VIEW SIDE VIEW Inches Millimeters Model FSH 5 amp FSH 6 Installation 2 05 3 Oven limitations Electric Appliances Only Max kW Input Total all Ovens Hood Max Temp 2 05 4 Oven clearances MIN 14 355 08 72 max 1828 8 ceiling mount 68 max 17272 stand mount FSH 6 60 max 1522 0 ceiling mount 56 max 1422 4 stand mount FSH 5 MIN 0 00 114 2895 60 Ceiling 117 3 16 2976 56 72 Stand 123 1 8 312738 78 Stand MIN CEILING HEIGHT 36 MAX 914 93 42 1066 8 lmax FRONT VIEW SIDE VIEW Inches Millimeters 10 Installation Model FSH 5 amp FSH 6 2 05 5 Griddle limitations Electric Appliances Only Hood Max Temp Max kW Input Max Cooking Surface FSH 5 48 X 26 2 05 6 Griddle clearances side to side overhang requirement does not apply with Stand Mount model 14 MIN 355 08 1 1066 8 838 2 MIN 123 1 8 312738 78 Stand MIN CEILING HEIGHT 5 5 MIN 381 00 33 42 114 2895
13. 60 Ceiling 117 3 16 2976 56 72 Stand 6 MIN 152 40 0 when using stand option 6 MIN 152 40 0 when using stand option lat COOKING SURFACE FRONT VIEW SIDE VIEW Inches Millimeters 11 Model FSH 5 amp FSH 6 Installation 2 05 7 Range limitations Electric Appliances Only Max kW Input Max Burners 2 05 8 Range clearances side to side overhang requirement does not apply with Stand Mount model T d 0 0 c z 33 838 2 MIN 42 1066 8 MAX 2 5 MIN 381 00 114 2895 60 Ceiling 117 3 16 2976 56 72 Stand 123 1 8 3127338 78 Stand MIN CEILING HEIGHT 6 MIN 152 40 0 when using stand option 6 MIN 0 when using stand option e COOKING SURFACE FRONT VIEW SIDE VIEW Inches Millimeters 12 Installation Model FSH 5 amp FSH 6 2 06 Hood Electrical Requirements Consult a qualified electrician to ensure all electrical specifications have been met and that the unit is properly grounded Improper installation adjustment alteration service or maintenance could result in death or serious injury equip ment or property damage and void the warranty Hood Electrical Requirements Voltage Hz Phase Amps Breaker 208 240 60 1 15 20 208 240 60 1 15 20 2 06 1 Electrical Connections 1 Ins
14. Baffle Filter Removal Li 28 2402095 B ffle Filter Iictallationis FEVER em EXER ROTER XU REESE Ex dows 29 440204 Bartle Filter MISSING aus dE RES EE ERE DER EE uma yaqa oaa 29 402 05 Battle Filter x luys acea tse qna EE s ie CC ATA IHRER De wasa ai 30 4 02 06 Pre Filter 30 4202 07 Pre Filter Installation 3x eni 31 4 02 08 Pre Filter Filter Missing 31 4 02 09 Pre Filter Replacement 0 0 0 0 rs 32 4 02 10 EAC n uar 32 2402 01 EAC Filter Installation cres seven ia E 33 4 02 12 EAC Filter RESTER oe IDE SERE ped eis 34 AO 13 EAC Filter Cleanings vue yusa ok Nace xoa OIL RR exw a QN gea dS 34 4 02 14 Charcoal Filter Removal usa oe oho RS LIE 35 2402 15 Charcoal auum ev der v eo re Sue dass EE eR e Re CRUS 36 4 02 16 Charcoal Filter MISSING s 654 04544544 4650054 ened RES S 36 4402 12 Charcoal Filter Replacement E acd nit dia oan doa Su 37 4 02 18 Ultra Violet Lamp Cleaning en 37 4 02 19 Ultra Violet Lamp Removal red e
15. Operations amp Service Manual FSH 5 amp FSH 6 IRR _ UV ULTIMATE VENTLESS Models FSH 5 amp FSH 6 Giles Enterprises Inc ISO 9001 Registered Company Committed to Quality 2750 Gunter Park Drive West Montgomery AL 36109 USA Phone 334 272 1457 Fax 334 239 4117 Website www gfsequipment com Service Hotline Toll Free 800 554 4537 USA amp Canada Only Form No 64898 Release date 7 99 Revision Date 08 23 10 Rev E FOODSERVICE EQUIPMENT GILE FOODSERVICE EQUIPMENT LIMITED WARRANTY Subject to the terms and conditions of this Limited Warranty as herein stated all Giles Enterprises Inc Foodservice Equipment and parts purchased new from an authorized Giles Enterprises Inc representative are warranted as to defects in material or workmanship for a period of 12 months from the date of installation provided however that with regard to labor costs in connection with this warranty see below All installations must be made by a qualified installing agency in accor dance with all applicable codes and or regulations in the jurisdiction in which installed Limited war ranty coverage is extended to the original owner only and is void if the unit is resold During the Limited Warranty period Giles Enterprises Inc will replace or recondition at its factory any part or parts of this unit which Giles Enterprises Inc inspectors judge defective provided the unit has been
16. UTION notices may result in minor or moderate injury equipment or property damage and void the warranty The electronic components of the Control Panel are impact sensitive Exercise care around the Control Panel to maintain proper operation Do not attempt to dry the EAC after cleaning by installing it and running the hood to force air dry or by running an appliance below to heat dry This could potentially damage the EAC system leading to failure and voiding the warranty The filter must air dry at ambient room temperature preferably overnight During cleaning of Hood ee DO NOT steam clean ee DO NOT use products containing chlorine ee DO NOT use abrasive products steel wool or scouring pads Failure to comply with these CAUTION notices may result in equipment property damage and void the warranty vii Model FSH 5 4 FSH 6 Safety NOTE If upon receipt the palletized unit shows any signs of damaged immediately inspect the entire Ventless Hood and the included accessories and promptly notify the freight company of any damages aid the electrician an electrical wiring diagram is attached inside the back cover of this manual Refer to the wiring diagram during installation or servicing A wiring diagram is also attached to the inside of the filter access door Comply with all appropriate state and or local heath regulations regarding the cleaning and sanitation of equipment e For difficult a
17. aaa lat 56 Safety Model FSH 5 amp FSH 6 Safety Overview The instructions contained in this manual have been prepared to aid you in learning the proper procedures for installing and servicing your unit Throughout this manual safety precautions are identified through the use of the safety alert symbol and three signal words DANGER WARNING and CAUTION All safety alert information precedes the step s to which they apply Suggested recommended or other noteworthy information is identified through the use of NOTES Additionally certain words are used to indicate a specific meaning or to add emphasis The following words are used as indicated throughout the manual Shall understood to be mandatory Should understood to be advisory May understood to be permissive Will indicates a future event condition to occur N or Safety Alert Symbol Used in conjunction with signal words DANGER WARNING or CAUTION to alert you of potential personal injury hazards immediately preceding precautionary measures that pertain to subsequent step s Obey all safety messages that follow this symbol to avoid possible injury or death Failure to adhere to safety precautions identified by the safety alert symbol may also void the warranty Indicates an imminently hazardous situation which if not avoided will result in death or serious injury Use of this is limited to the most extreme situations Indicates a potentially hazardous
18. ading to less maintenance This lamp should be cleaned monthly and replaced annually The Hood Skirt helps contain and capture grease laden vapors produced by the cooking appliance Exhaust Outlet The Exhaust Outlet located on front of the unit exhausts the filtered air back into the room A minimum clearance of 14 must be maintained between the top of the Exhaust Outlet and the Ceiling or other obstruction for proper air flow Grease Drip Cup The Grease Drip Cup is used to catch grease condensate generated at the Baffle Filters This cup must be emptied and cleaned daily Model FSH 5 amp FSH 6 Overview 3 03 Accessories Included Part Description Part Number 2 Baffle Filter P N 42300 Function Removes large particle contaminant from the air 2 Pre Filter P N 91707 Removes additional grease laden vapors from the air EAC Filter P N 20521 LEFT P N 20520 RIGHT 24 Removes smoke and small particle contaminant from the air Overview Model FSH 5 amp FSH 6 3 03 Accessories Included Description Part Number 2 Charcoal Filter P N 32056 Function Helps remove odors from the air EAC Soak Tank P N 39327 Used for soaking and cleaning EAC filter 2 Ultra Violet Lamp P N 90226 Used for maximum emission control 25 Model FSH 5 amp FSH 6 Overview Notes 26 Operation amp Filter Maintenance Model FSH 5 a
19. aning and Maintenance 5 3 Semi Annual Fire Suppression System Service Consult the Giles Enterprises Design Installation Recharge and Maintenance Manual for complete servicing guidelines Servicing and inspection of the fire suppression system must be performed by certified qualified fire protection equipment specialists As a minimum field inspection of the Fire Suppression System must be conducted semi annually Such maintenance shall consist of the following Place fire extinguishing system locking bar on fire system when inspecting or servicing 1 Inspect storage tank for chemical level and charge pressure Inspect release mechanism 2 Check all nozzles to insure they are free of grease buildup See Section 2 06 4 Extinguisher Nozzle locations Test the remote manual pull station for activation and wear Install test link and cut to simulate automatic actuation Clean and inspect fusible links See Section 2 06 2 for Fusible Link locations Inspect fusible link wire cabling for wear at pulleys and detectors replace if necessary ON Oa P Record maintenance date and service performed in a permanent file 5 4 Annual Fire Suppression System Same as Semi Annual but all fusible links must be replaced with new fusible links See Section 2 06 2 Fire Suppression Fusible Links 5 5 12 Year Fire Suppression System Same as Annual except for the following 1 Replace R 102 fire suppressant chemical 2 Hydrostatically t
20. e PAL Close Door 4 02 08 Pre Filter Filter Missing If either Pre Filter is missing or not in place correctly and the unit is on the Filter Missing Light EB Will illuminate and power to cooking appliance is interrupted until the condition is corrected See Section 4 02 07 Pre Filter Installation 31 Model 5 5 amp FSH 6 Operation amp Filter Maintenance 4 02 09 Pre Filter Replacement NEVER attempt to clean and re use the Pre Filters This could cause damage to the unit Replace the Pre Filters weekly Use Replacement Part No 91707 NOTE e When filters are changed always record the installation date in the space provided on the filter label 4 02 10 EAC Filter Removal 1 Place in OFF position Left EAC Filter Right EAC Filter Door open EAC Filter Folding Handle 32 Operation amp Filter Maintenance Model FSH 5 amp FSH 6 4 02 11 EAC Filter Installation Left EAC Air Flow Arrow Filter Contact Hood Contact Plate Plate Right EAC Air Flow Arrow EAC alignment Pin I EAC Filter Folding Handle Plates must make contact If either EAC Filter is missing or not properly positioned all 3 EAC LED s will illuminate and after approx 2 minutes an intermittent tone alarm will sound Power to the interlocked under hood cooking appliance s is interrupted until the condition is corrected 33 Model 5 5 amp FSH 6 Operation am
21. e time to record the installation date in space provided on the new filter label 4 02 18 Ultra Violet Lamp Cleaning DO NOT touch or handle UV Lamp glass with bare hands This will greatly reduce the life of the bulb Recommend performing this cleaning every 30 days 1 Turn hood power switch to the OFF position 2 Open filter access door 3 Loosen and remove thumb screws E on holding bracket and remove the lamp guard 4 Lightly spray a mild non caustic bio degradable degreaser such as Simple Green onto the UV lamp and wipe off residue with a dry lint free cloth DO NOT TOUCH THE LAMP GLASS WITH BARE HANDS 5 Re install lamp guard and secure thumbscrews LE MEE cic mm seit eten ALTER E LE FLIER uisum SIDE SIDE R 1 6 e e e 37 Model 5 5 amp FSH 6 Operation amp Filter Maintenance 4 02 19 Ultra Violet Lamp Removal Place hood power switch to the OFF position Open filter access door ES Remove Charcoal filters see section 4 02 14 Disconnect UV Lamp wiring harness plug from power supply wiring receptacle Loosen and remove thumb screws EB on the lamp guard Oa Cn Remove lamp E3 from holding bracket ep NE Hic gt SUES ae FLIER wisama SI 38 Operation amp Filter Maintenance Model FSH 5 amp FSH 6 4 02 20 Ultra Violet Lamp Installation 1 Install new UV lamp in h
22. es with a dunking motion to help dislodge grease residue 4 Carefully remove the EAC from the tank and rinse thoroughly in a sink using hot water Allow the cell to air dry thoroughly 6 Inspect cell for broken wires or bent fins Have broken wires replaced promptly Bent fins may be gently straightened by hand if needed NOTE The EAC cell is NOT designed to withstand washing in commercial dishwashers 34 Operation amp Filter Maintenance Model FSH 5 amp FSH 6 4 02 14 Charcoal Filter Removal 1 Place in OFF position Charcoal Filter Door open Front View 35 Model 5 5 amp FSH 6 Operation amp Filter Maintenance 4 02 15 Charcoal Filter Installation Door open Blue Foam Side N Charcoal Filter Switch Roller must be actuated by the Charcoal Filter as shown Front View Close Door 4 02 16 Filter Missing If the Charcoal Filter is missing not in place correctly and the unit is on the Filter Missing Light EB will illuminate and power to cooking appliance is interrupted until the condition is corrected See Section 4 2 15 Charcoal Filter Installation 36 Operation amp Filter Maintenance Model FSH 5 amp FSH 6 4 02 17 Charcoal Filter Replacement NEVER attempt to clean and re use the Charcoal Filters This could cause damage to the unit Replace the Charcoal Filter every 30 days Use Replacement Part No 32056 Please take th
23. est the holding tank and charging cartridge Can be replaced with new components that have current hydrostatic certifications 3 Flow test the regulator 42 Hood Cleaning and Maintenance Model FSH 5 amp FSH 6 5 6 Maintenance amp Service Log Check Initial Date Check Initial Date A ABC 1 2 08 2 3 4J J5 _ l 2 3 4 5 J e 1 2 3 4 5 l 1 2 3 4 5jJ6 J 1 21 13 4 5 16 l 21 5 4 5 112 3 4 5 _ 1 2 3 4 5 J jJ 1121314151617 o _ 1 1 2 3 4 5 6 7 8 ETL249L4 5 E 1 11213141051 5 4 4 4 4 4 1 Ee 1 2 3 4 5 J TA 3 4 5 jJ 11213141051 J 5 jJ o i 1121314151617 81 11 2 3 4 5 6 7 9 Must be performed by a certified qualified fire protection equipment company i i i i i i i i i i i i i i i i i i i i i i i i 6 Quarterly Cleaning ire Suppression System Tier Clogged ire Suppression System replace Fusible Links 43 Model FSH 5 amp FSH 6 Hood Cleaning and Maintenance Notes Troubleshooting Model FSH 5 amp FSH 6 6 Troubleshooting This section describes basic troubleshooting procedures for the FSH 5 amp 6 The wiring diagram attached inside the back cover is provided to assist qualified technicians with more in depth troubleshooting Electrical troubleshooting p
24. hat the hazard has not changed Verify that system pressure is nominal Inspect the soundness of the discharge spray nozzles and fusible links Ensure the system is properly located with respect to the appliance Verify the date the unit was manufactured Check to be sure the service tag is attached indicating what service was performed and when per formed Ansul is a registered trademark PS 17 Model FSH 5 amp FSH 6 Installation NOTES Overview Model FSH 5 amp FSH 6 3 Overview The following section provides a brief overview of the components functions and accessories of the FSH 5 and the FSH 6 Please review this section carefully before proceeding any further Right Left UV Sight UV Sight Hood Exhaust Window Window UV option only UV option only Right Filter Chamber Figure 3 2 Left Filter Chamber Figure 3 2 Control Panel Figure 3 1 Hood Skirt 19 Model FSH 5 amp FSH 6 Overview 3 01 Control Panel o E ILS Only not shown 20 Overview Model FSH 5 amp FSH 6 3 01 Control Panel Item Description Light Switch Function Used to turn the hood light on and off PUSH to START Button After the Power Switch is in the ON position push and hold down PUSH to START Button for 5 seconds Used only in units with Inter Locking Start ILS
25. leshooting Procedures Cont d Problem Appliance will not heat e Hood power FILTER MISSING light ON Appliance will not heat e Hood power e Alarm emitting a continuous tone Appliance will not heat e Hood power e CHECK and or WASH LED s ON e Alarm emitting an intermittent tone 46 Probable Cause Baffle Filter missing Troubleshooting Corrective Action Install Baffle Filter Baffle Filter not installed properly Reinstall Baffle Filter Charcoal Filter missing Charcoal Filter clogged Install Charcoal Filter Replace Charcoal Filter Baffle Filter clogged Clean Baffle Filter Clogged filter switch out of adjustment Adjust clogged switch only initial start up switch bad Kinked vacuum line Remove vacuum line kinks Fan running slow Check voltage EAC shorted Repair EAC EAC dirty Clean EAC EAC power supply faulty Replace EAC power supply EAC wires shorted Check voltage Bad contact plate Replace contact plate EAC module faulty Replace EAC module EAC ionizer wire broken or missing Replace ionizer wire Parts List Model FSH 5 amp FSH 6 Z Parts List This section lists various replacement parts available for the FSH 5 and FSH 6 7 1 Parts Ordering and Service Information If you require assistance or need repairs please contact an area Giles dealer to assist with locating service p
26. mp FSH 6 4 Operation amp Filter Maintenance This section describes Hood operation and filter maintenance 4 01 Hood Operation Starting the Ventless Hood Make sure all Filters are in place and filter access doors are closed before attempting to operate the unit NOTE The hood will NOT power up if either filter door is open 1 Press the Power Switch to the position if the hood is an ILS model press and hold the Push amp Hold to Start button A for 5 seconds The EAC ON light E will illuminate and the fan will start If equipped the Ultra violet lamps will illuminate and be visible in the UV sight windows EM The appliance under the hood which is interlocked to the hood may now be turned on 2 Press the Light Switch 4 to the ON position to turn on the underhood lights usEmo SIDE s UV Only L3 ILS Only 4 02 Filters and Filter Maintenance Filter System operation cleaning and maintenance schedule 4 02 01 Ventless Hood Filter Table Filter a a or How to remove How to clean How to install Baffle Filter Clean daily Section 4 02 02 Section 4 02 05 Section 4 02 03 Never clean Pre Filter Replace weekly Section 4 02 06 Replace Only Section 4 02 07 Section 4 02 09 EAC Filter Clean daily Section 4 02 10 Section 4 02 13 Section 4 02 11 Never clean Section 4 02 14 Replace Only Section 4 02 15 Section 4 02 17 Replace every 30 Charcoal
27. n power switch OFF and reinstall EAC Filter Follow the same procedure to check right side EAC Filter 4 Charcoal Filter Check Place power switch in the OFF position remove the left side Charcoal Filter and close door turn power ON Filter Missing Light should be illuminated Check appliance power there should be none Turn power switch OFF and reinstall Charcoal Filter Follow the same procedure to check the right side Charcoal Filter 5 Filter Clogged Check Place Hood power switch in the ON position The blower will start and a continuous tone alarm should sound for 2 to 8 seconds until the blower reaches speed then silence Check appliance s power during this time there should be no power supplied to appliance s until the alarm silences If the alarm tone does not sound fails to silence and or the appliance s fails to come on or comes on before the alarm silences contact service agent and have the Clogged Filter interlock checked Return Hood power switch to the OFF position 5 2 Quarterly Hood Cleaning To maintain effectiveness and performance the hood must be cleaned at a minimum every 3 months Disconnect power from the unit preferably at a breaker Remove all filters from the hood Using soft cloth sponge or towel and a mild bio degradable degreaser clean the entire hood plenum and blower section Any grease build up on the fan blades should be removed during this cleaning 41 Model FSH 5 amp FSH 6 Hood Cle
28. olding brackets 2 Install and tighten holding bracket thumb screws EB 3 Connect UV lamp wiring harness to power supply wiring receptacle 4 Re install Charcoal filters see section 4 02 15 5 Close filter access door 6 Place hood power switch the ON position O82 FAG FLIR LEFT SI 39 Model FSH 5 amp FSH 6 Alarm Sound Continuous tone What will happen Alarm will sound and power to the appliance will shutdown If ILS hood fan will also shutdown Operation amp Filter Maintenance Filter effected Charcoal or Pre Filter Filter dirty Solution Replace Filter 4 03 Filter Alarm Chart See Section Continuous tone Alarm will sound and power to the appliance will shutdown If ILS hood fan will also shutdown Baffle Filter dirty Clean Filter 4 02 03 and 4 02 05 Intermittent tone 40 Check and or Wash LED s will illuminate alarm sounds after approx 2 minutes power to the appliance is shutdown If ILS model the hood fan will also shutdown Filter dirty Clean Filter 4 02 11 and 4 02 13 Hood Cleaning and Maintenance Model FSH 5 amp FSH 6 5 Hood Cleaning and Maintenance This Section describes cleaning and maintaining the Hood System Attention to these procedures will help ensure the hood remains efficient over time
29. ot specifically stated herein Repair or replacement as provided under this limited warranty is the exclusive remedy Giles Enterprises Inc shall not be liable for any incidental or consequential damages for breach of any express or implied warranty on this product except to the extent prohibited by applicable law Any implied warranty of merchantability or fitness for a particular purpose on this product is limited in duration to the duration of this limited warranty Used Giles Enterprises Inc Foodservice Equipment or parts or Giles Enterprises Inc Foodservice Equipment or parts not purchased from an authorized Giles Enterprises Inc representative carry no warranties express or implied SILE FOODSERVICE EQUIPMENT Table Of Contents Model FSH 5 amp FSH 6 Safety unicus isa i iii dii V Salet OVES V Specific Safety Precautions liliis hh vi 1 1 1 1 CONSU CHON fs Loire pe BE n Ge mete ea 1 1 2 Standard usur role feste 1 1 3 Optional sma cow cep S SS SR panay adr i 1 1 4 C CEU TE CIO COSTI LR TERI NL 2 1 4 1 Overall Dimensions for FSH 5 amp 6 Ceiling 2 1 4 2 Overall Dimensions for FSH 5 amp 6 Stand 3 1 4 3 NOI 22 one
30. p Filter Maintenance 4 02 12 EAC Filter Status Three LED indicator lights on the Control Panel display the status of each EAC Filter F ON The EAC Filter is in place powered and operating properly Ei WASH When ON indicates the collection fins are becoming excessively dirty and must be cleaned After approx 2 minutes in this condition an intermittent tone alarm will sound and power to interlocked under hood cooking appliance s will be interrupted until the condition is corrected EI CHECK When ON indicates the Filter is not operating There is either a poor connection at the contacts or the filter is damaged After approx 2 minutes in this condition an intermittent tone alarm will sound and power to interlocked underhood cooking appliance s will be interrupted until the condition is corrected 4 02 13 Filter Cleaning The EAC Filter should be cleaned daily Do not bend the fins or break the ionizer wires on the EAC as this will prevent the electrostatic collecting cell from performing properly and potentially void the warranty 1 Add 1 2 gal of a mild degreaser such as Simple Green or Clean Magic to the Soak Tank add water to fill line X s and mix 2 Holding the cell by the contact plate carefully lower the BJ into the mixed degreasing solution 3 Allow the EAC to soak for 20 to 30 minutes Grasping it by the contact plate lift and move it and down several tim
31. reas with excessive particulate build up a mild bio degradable non toxic degreaser such as Clear Magic or Simple Green may be used Always ensure the unit is electrically grounded and installed in accordance with local codes or in the absence of local codes in accordance with the National Electrical Code ANSI NFPA No 70 1984 NOTE The decibel level of the hood when operating is approximately 73 dB NOTE e A HVAC specialist may be required for some installations to confirm proper air exchange and the heat load capabilities of the on site AC system Exhaust ventilation is recommended for areas in which recirculating hoods used We recommend 50 CFM per lineal ft of hood This amount could vary based on local codes and the site specific installation requirements viii Introduction Model FSH 5 amp FSH 6 1 Introduction Congratulations on the purchase of a new FSH 5 or FSH 6 Giles Ventless Hood System manufactured by Giles Enterprises Inc Montgomery Alabama USA hereafter referred to as Giles These two models are available in either ceiling mounted or free stand mounted versions which are available in 72 and 78 heights as measured from the floor to the bottom edge on the hood skirt Proper care and maintenance of this unit will ensure years of trouble free service and to help protect your investment in this equipment we recommend taking a few moments to familiarize yourself with the in
32. rease extraction and air cleaning system found in these units The filters are eas ily removed for daily cleaning DO NOT remove the Filter while the hood is operating to prevent contact with electrical parts and avoid electrical shock The Baffle Filter should be cleaned daily 2 Pre Filter Pre Filters remove additional grease laden vapors from the air stream To prevent contact with electrical parts and avoid electrical shock DO NOT remove the Pre Filter s while the hood is operating NEVER attempt to clean and re use the Pre Filters Replace with new filters weekly EAC Filter Left and Right EAC Filters are electrostatic devices that remove grease vapor and smoke generated by the appliance during cooking To pre vent contact with electrical parts and avoid electrical shock DO NOT remove the EAC Filter while the hood is operating The EAC should be cleaned daily 2 Charcoal Filter Charcoal Filter helps to eliminate cooking odors These Filters should be replaced monthly To prevent contact with electri cal parts and avoid electrical shock DO NOT remove the Charcoal Filter while the hood is operating NEVER attempt to clean and re use the Charcoal Filters Replace with new filters every 30 days 2 Ultra Violet Lamps optional Hood Skirt Improves emission elimination and odor control as well as keeping the exhaust plenum and duct free of grease build up improving fire safety and le
33. rocedures should be performed ONLY by a qualified service technician electrician Death or serious injury will result from contact with energized electrical components e Failure to comply with these DANGER notices will result in death or serious injury equipment or property damage and void the warranty 6 1 Troubleshooting Procedures Problem Hood will not turn on Filter Missing Light illuminated Initial Start up Only Check or Wash LED illuminated e LED light cluster for each side s filter Probable Cause ILS Only HOLD TO START button not held for 5 seconds Corrective Action Hold down HOLD TO START Faulty power switch Replace power switch Improper supply voltage Connect to proper voltage source Filter Access Door not closed Close access door Not properly connected to power source Connect to proper power source Blown fuse or tripped circuit breaker Baffle filter is not installed Check the fuse or breaker Install Baffle filter Charcoal filter is not installed Install charcoal filter Pre Filter is not installed EAC shorted Install pre filter Replace or repair EAC EAC dirty Clean EAC High voltage power supply faulty Replace high voltage power supply High voltage wires shorted Correct shorted condition Bad contact plate Replace contact plate Model FSH 5 amp FSH 6 6 1 Troub
34. rovider in your area or for further assistance please contact Giles Enterprises directly at the following phone numbers IN THE UNITED STATES CANADA or MEXICO Please call 800 554 4537 during normal business hours 8 00AM to 5 00PM Central Time other than normal business hours call 800 554 4537 and follow recorded prompts to reach after hours support IN ALL OTHER COUNTRIES Please call 334 272 1457 during normal business hours 8 00AM to 5 00PM Central Time other than normal business hours call 334 272 1457 and follow the recorded prompts INTERNET Please visit our website at www gfsequipment com or e mail services gfsequipment com The goal of the Giles team is to provide you with the highest quality service and assistance You can help us accomplish this by obtaining the following information and having it readily available when calling The information is recorded on a Serial Plate or Label attached to the unit Serial Plate Record information here for quick reference in the future Model Name Serial Number Phase Voltage PM Nature of Problem 47 Model FSH 5 amp FSH 6 Parts List 7 2 Component Drawer FSH 5 and FSH 6 DUNGS Kart Dunga ine I Une Laisa MN USA OBL FILTER FILTER LEFT IDE RIGHT SIDE UV Only 48 Parts List Model FSH 5 amp FSH 6 7 2 Parts List for Component Drawer FSH 5 and FSH 6 6 2 LED EAC STATUS INDICATORS 8 2190
35. situation which if not avoided could result in death or serious injury Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury Also used to alert against unsafe practices When used without the safety alert symbol CAUTION indicates potentially hazardous situation which if not avoided may result in equipment property damage and void the warranty NOTE dentifies suggested recommended or other noteworthy information v Model FSH 5 amp FSH 6 Safety Specific Safety Precautions For your safety please observe the following precautions when operating or servicing your Ventless Hood Model FSH 5 or FSH 6 Read the following important safety information to avoid personal injury and or damage to the equipment Always disconnect the source of the main power before removing the service entrance box cover e Failure to ensure the Power switch is in the OFF position during servicing and when replacing filters could result in equipment damage electrical shock and or personal injury e Failure to comply with these DANGER notices will result in death or serious injury equipment property damage and void the warranty DO NOT use or store flammable liquids or materials that produce flammable vapors in the vicinity of this or any other appliance Consult a qualified electrician to ensure all electrical specifications have been met and the unit is properl
36. stallation cleaning and maintenance procedures described in this manual We urge you to read these instructions before installing or using this equipment Adherence to these recommended procedures will minimize potential for costly downtime and equipment repairs Please retain this manual for future reference 1 1 Construction The Ventless Hood System exterior is constructed of stainless steel 1 2 Standard Features Control Panel Two LED light clusters indicate the status of the left and right EAC filters Filter Missing light indicates that one or more of the Baffle filters Pre filters and or Charcoal filters is missing or installed improperly Filters e Baffle Filters capture large grease particles in the air stream Pre Filters capture the smaller grease particles Electronic Air Cleaners EAC capture smoke amp fine particle air contaminates Charcoal Filters help eliminate cooking odors 1 3 Optional Features Inter Locking Start System ILS nter Locking Start System ILS Should there be a power interruption to the the hood this system will not allow the Hood and the Appliance s below it to restart without the attendance of an operator This system is required by code in some cities and or states Please consult with your local code officials to see if this option is required Floor Stand Mount 72 or 78 high stand mounts are available instead of the standard ceiling hung mount
37. subjected to normal usage properly installed operated and serviced This Limited Warranty does not cover cosmetic damage and damage due to acts of God accident misuse alter ation negligence abuse of the Giles Foodservice Equipment or the use of unorthodox repair meth ods All parts replaced under this Limited Warranty carry only the unexpired term of this Limited Warranty Limited Warranty service may be furnished only by an authorized Giles Enterprises Inc representative If Limited Warranty service is requested Giles Enterprises Inc will send factory authorized serv ice representatives to repair recondition replace or inspect units of its manufacture with such labor being rendered without cost to owner for ninety 90 days from the date of installation Otherwise service including labor and transportation charges or other expenses in connection with the removal or installation of any part or parts supplied under this Limited Warranty are specified on the original sales contract between the purchaser and the authorized Giles Enterprises Inc represen tative Giles Enterprises Inc reserves the right to change or improve its equipment and parts in any way without obligation to alter such equipment or parts previously manufactured Giles Enterprises Inc makes no further warranties express or implied including implied warranties of merchantability or fitness for a particular purpose and has no other obligation or liability n
38. t and other packed components and notify the freight company of any and all damages 2 Cut and remove the stretch wrap and all strapping 3 Use a hammer and pry bar to remove the wooden frame from around the unit Use suitable equipment to lift the hood and carefully move it away from the pallet see Section 1 4 4 for hood weights Take precautions not to damage to the hood s bottom skirting If possible it is advisable to rig and lift the hood from the topside utilizing the hood s hanging brackets Exercise care when removing the wooden framing from around the unit Failure to comply with these CAUTION notices may result in minor or moderate injury equipment or property damage and void the warranty Model FSH 5 amp FSH 6 Installation 2 02 Location NOTE The decibel level of the hood when operating is approximately 73 dB DO NOT MODIFY ALTER OR ADD ATTACHMENTS TO THIS EQUIPMENT NOTE e A HVAC specialist may be required for some installations to confirm proper air exchange and the heat load capabilities of the on site AC system Exhaust ventilation is recommended for areas in which recirculating hoods are used We recommend 50 CFM per linear ft of hood This amount could vary based on local codes and the site specific installation requirements 1 Do not obstruct the exhaust air outlet Maintain a minimum clearance of 14 inches 355 6mm between the air outlet and ceiling or any obstruction
39. tall appropriate Circuit Breaker in Main Breaker Box See Section 2 05 2 Connect appropriate size wire to the Main Breaker 3 Reinstall Service Panel 4 Turn Main Breaker on 5 Press the Hood power switch to the ON position If ILS with power in ON position press and hold the Push to Start button for 5 secs Model FSH 5 amp FSH 6 Installation 2 06 2 Routing Power Wires EXTING ALARM SHUT DOWN Hood and Appliance Interlock Diagram HOOD ALARM INTERLOCK TIE IN BOX 9 SENTROL POMERI HOOD CONTROL POWER Lee ye ge LOAD CENTER BOX SUPPLIED BY CUSTOMER pem EXTINGUISHER SWITCH SUPPLIED BY FIRE EXTINGUISHER COMPANY Ls FIRE EXTINGUISHER ACTUATION BOX SUPPLIED BY FIRE EXTINGUISHER COMPANY 3 V m T MI ale Ri 4 A 4 E cs M3 1 F 32 3 um lt L3 CONTACTOR LOAD CENTER CIRCUIT BREAKER SUPPLIED BY CUSTOMER SUPPLIED BY CUSTOMER CONTACTOR BOX LOAD CENTER BOX APPLIANCE SUPPLIED BY CUSTOMER SUPPLIED BY CUSTOMER SUPPLIED 8Y CUSTOMER 14 Installation Model FSH 5 amp FSH 6 2 07 Fire Suppression System Installation It is a requirement that the Giles FSH 5 amp 6 Ventless Hood System be protected by a UL Listed fire sup pression system Installation is
40. to be performed by an Authorized Fire Suppression Agent in accordance with the system listing The FSH 5 amp 6 hood system is pre piped at the factory and contains supply line plenum nozzles and fusible link brackets Appliance nozzles and drop downs are not included The hood has been designed to accommodate either left or right side hook up The electrical switch requirements are identi cal to those listed in the Ansul R 102 Installation Manual with the hood system acting as the customer supplied switch 1 Appliance nozzles shall be positioned 11 279 4mm below the lowermost front edge of the hood 2 The use of both appliance nozzles is required at all times 3 A manual pull station for the Fire System is to be installed and located in a path of exit or egress The pull station must be clearly marked and easily accessible 4 Regulated Release Assembly shall be of the mechanical type Ansul P N 79290 2 07 1 Fire Suppression System Routing Fire Extinguisher Nozzle Connection Fusible Link Connection Regulated Release Assembly Ansul P N 79290 Note System may located and connected the left right of the hood 15 Model FSH 5 amp FSH 6 Installation 2 07 2 Fire Suppression Fusible Links 285 F Degree E Factory installed x 3 165 F Degree 165 F Degree A Ansul P N 56811 Ansul P N 56811 165 F Degree 7
41. trical Requirements lile 13 2 06 1 Electrical C ontiectlOfls cres eer uda Ses ale d uet pue moon Sa died vel ated 13 2 06 2 ROUTING Power VVITGS ise e ys eae us eoe ups 14 2 06 3 Hood and Appliance Interlock Diagram 14 2 07 Fire Suppression System Installation iL 15 2 071 Fire Suppression System ROULING sis uice rieri merrer eee ER CERE ERR SQL SEEN 15 2 072 Fire Suppression FUSIDIG LINKS xs ve bo cutee 16 2 073 Appliance Nozzles iu usce eR RR dad dae US A a bes 16 2 074 Fire Extinguisher Nozzle 5 17 2 075 General Maintenance 2 2 i caw oon Ge yee rr er eX beato 17 3 OVGIVIEW gt A 19 3 01 ie d mentee k ka 20 3 02 Filter Chamber and Exhaust silice donee de gas be daba gus 22 3 03 Accessories 24 Model FSH 5 amp FSH 6 Table Of Contents 4 Operation amp Filter Maintenance 27 4 01 rrr 27 4 02 Filters and Filter Maintenance 27 4 02 01 Ventless Hood Filter Table 27 4 02 02
42. unt Skirts Not Shown 56 Parts List Model FSH 5 amp FSH 6 7 6 Parts List for Stand Mounted Skirts 1 958 1 72 HOODSTANDSIDELEFT O Z o O o y O 1 91524 1 78 HOODSTANDSIDE LET 2 9586 1 72 HOOD STAND SIDE RIGHT o Z o O y y O 2 91577 1 78 HOODSTANDSIDERIGHT O Z O O O 994 1 72 TOPBACKPANEL FS 5 3 91988 1 72 TOPBACKPANELFSH G6 O Z O Z O O O O 3 900 1 78 TOP BACK PANEL FSH5 O Z O y O 3 92007 1 78 TOPBACKPANEL FSH 6 O Z O Z O O O 4 9147 1 72 BOITOMBACKPANELFSH5 O O Z O Z O 4 9140 1 72 BOTTOMBACKPANELESH6 O Z O Z O Z 4 9200 1 78 BOTTOMBACKPANELFSH5 O O Z O Z 4 9200 1 78 BOTTOM BACK PANEL FSH 6 O as 5 92063 2 APPLIANCE POSITIONING CHANNEL FSH 6 HOOD SKIRT 8 STAND MOUNT FSH 5 NE 6 9195 1 HOOD SKIRT 8 STAND MOUNT FSH 6 1 1 2 2 3 3 3 3 4 4 4 4 5 5 Not Shown 57 Model FSH 5 amp FSH 6 Parts List Notes 58 Model FSH 5 amp FSH 6 GILE FOODSERVICE EQUIPMENT Giles Enterprises Inc 2750 Gunter Park Drive West Montgomery Al 36109 USA Phone 334 272 1457 Service Hotline 800 554 4537 USA amp Canada Only FAX 334 239 4117 www gfsequipment com Form No 64898 Release date 07 99 Revision Date 08 23 10 Rev E
43. y grounded Before installing or servicing this equipment read the contents of this manual thoroughly Improper installation adjustment alteration service or maintenance could result in death or serious injury equipment property damage and void the warranty Failure to comply with these WARNING notices could result in death or serious injury and equipment or property damage A WARNING J for UV Models Only Internal ultraviolet radiation source present Keep protective barrier in place Replace all removable parts after servicing An interlock is in place to reduce the potential of exposure to excessive ultraviolet radiation DO NOT attempt defeat or bypass this interlock system vi Safety Model FSH 5 amp FSH 6 Maintain a minimum clearance of 14 355 6mm between the hood outlet and the ceiling or any obstruction above the hood 18 4572mm is recommended for best performance Exercise care when lifting or moving the unit See Section 1 4 4 for Hood weights Exercise care when removing the wooden crating from around the unit DO NOT operate the unit unless you fully understand the components and their intended function Be careful not to bend the fins or break the ionizer wires on the Electrostatic Air Cleaner EAC Doing so will prevent the EAC from working properly and cause a shutdown of power to the appliance being used with the hood Failure to comply with these CA