        Operator`s Manual CFR-4000
         Contents
1.        Note    describes information for the installation  operation  or maintenance of    which is important but hazard related if ignored           Z N CAUTION        Caution  indicates the presence of a hazard that could result in minor injury   or property damaged if ignored              CFR 4000 Operator   s Manual 7    2 2 Safety Symbols    The International Electro technical Commission  IEC  has established a set of  symbols for medical electronic equipment  which classify a connection or warn of any  potential hazard  The classifications and symbol s are shown below     Save these instructions    up  O   and O on power switch represent ON and OFF    respectively           This symbol identifies a safety note  Ensure you understand  the function of this control before using it  Control function is    described in the appropriate User   s or Service Manual     Identifies the point where the system safety ground is  fastened to the chassis  Protective earth connected to          gt     conductive parts of Class   equipment for safety purposes        Disposal of your old appliance       1  When this crossed out wheeled bin symbol is attached  to a product it means the product is covered by the  European Directive 2002 96 EC    2  All electrical and electronic products should be  disposed of separately from the municipal waste stream  via designated collection facilities appointed by the  government or the local authorities    3  The correct disposal of your old appliance 
2.    Load the standard frame which is provided as a standard accessory     Press MENU button and select the    CALIB  gt  gt  FRAME  menu  Refer to the section 6 1 for menu operation      Press the B button two times to trigger the automatic calibration    CFR 4000 Operator   s Manual 29     gt  It traces the standard frame on both sides twice      If it result in any error  check if the standard frame is loaded in correct position  and try again   gt  If it fails again  contact proper service engineer for maintenance      Preparation for the FRAME calibration    Standard Frame         FRAME calibration menu     11200 E GOTH Meu  B  Execute   CALIB  FRAME  OK      am                 ZNNorE          Calibration results are memorized automatically right after the completion of   each calibration      Be sure to check the related information before executing the calibration work  because you cannot get back the machine to the previous status      When a calibration seems not to be done properly  try executing the calibration  again      During the calibration  you may press the STOP button to abort the execution           30    CFR 4000 Operator   s Manual    Pattern Calibration      Purpose    Detecting the pattern reading position  axis  and calibrating the size       Procedure      Load the pattern holder with the standard pattern attached     Press MENU button and select the    CALIB  gt  gt  PATTERN  menu  Refer to the section 6 1 for menu operation     Press the B button two
3.  as an option to provide a means to input    job number     Variety of DCS communication options are provided to customize it for being com  pliant with different types of Lab Management Software  such as data format   points of data  angle type  communication speed  and more     1 3 Classification    Protection against electric shock  Class l earthed   Installation Category  II  Pollution Degree  2    6 CFR 4000 Operator   s Manual    2  Safety Information  2 1 Introduction    Safety is everyone   s responsibility  The safe use of this equipment is largely  dependent upon the installer  user  operator  and maintainer  It is imperative that  personnel study and become familiar with this entire manual before attempting to  install  use  clean  service or adjust this equipment and any associated accessories   It is paramount that the instructions contained in this manual are fully under stood  and followed to enhance safety to the patient and the user operator  It is for this  reason that the following safety notices have been placed appropriately within the  text of this manual to highlight safety related information or information requiring  special emphasis  All user  operators  and maintainers must be familiar with and pay    particular attention to all warning and cautions incorporated herein     Z   WARNING       Warning    indicates the presence of a hazard that could result in severe  personal injury  death or substantial property damage if ignored           Z N NOTE   
4.  times to trigger the automatic calibration  2 It traces the standard pattern twice      If it result in any error  check if the standard pattern is loaded in correct position  and try again     gt  If it fails again  contact proper service engineer for maintenance      Preparation for the PATTERN calibration    Pattern Holder    Standard Pattern                  PATTERN calibration menu    LEFT   D    B  Execute  IM B   CALIB  PATTERN           o       CFR 4000 Operator   s Manual 31    Stroke Calibration      Purpose    Detecting the maximum dimension of possible frame and pattern reading distance       Procedure      Load the standard frame which is provided as a standard accessory     Press MENU button and select the  CALIB  gt  gt  STROKE  menu   gt  Refer to the section 6 1 for menu operation     Press the B button two times to trigger the automatic calibration      If it result in any error  check the movement of the stylus in every direction and try  again     gt  If it fails again  contact proper service engineer for maintenance      Preparation for the STROKE calibration    Standard Frame         STROKE calibration menu    LEFT LI  BOTH  LI RIGHT  B  Execute      B     CALIB  STROKE a       wma               32 CFR 4000 Operator   s Manual    Standard Accessory    Standard Frame  for Frame Reader Calibration   Standard Pattern  for Frame Reader Calibration                    Pattern Holder e sim ule idc Rin minim m ch cM Ri in le urn aram Dn i m m M MGR Mn eim m ka 
5. 11    Only person who has undergone proper training and instructions are authorized  to install  use  operate  and maintain this equipment     Keep accompanied manual s  or technical materials  such as the User s  Manual and Service Manual  in a place easily accessible at all times for persons  operating and maintaining the equipment     Do not force cable connections  If a cable does not connect easily  be sure that  the connector  plug  is appropriate for the receptacle  socket   If you cause any  damage to a cable connector s  or receptacle s   let the damage s  be repaired    by an authorized service technician     Please do not pull on any cable  Always hold on to the plug when disconnecting  cables   Before every operation  visually check the equipment for exterior mechanical    damage s  and for proper function     Do not cover any ventilation grids or slits  Immediately turn off and unplug any  equipment that gives off smoke  sparks  strange noises  or odors     Risk of explosion if battery is replaced by an incorrect type  Dispose of used  batteries according to the instructions     This machine might be impaired if used in a manner not specified by    manufacturer and this manual        ZA WARNING       The equipment should be properly installed and operated based on the    instructions on this manual           12    CFR 4000 Operator   s Manual       LN WARNING       Do not disassemble the product without the proper training  It may cause the  electric shock  serio
6. CFR 4000 Operator   s Manual 1    Operator   s Manual    CFR 4000    For Remote Tracing       Huvitz    Pacing Progress toward People    2    CFR 4000 Operator   s Manual    IMPORTANT NOTICE    This product may malfunction due to electromagnetic waves caused by portable  personal telephones  transceivers  radio controlled toys  etc  Be sure to avoid  having the above objects  which affect the normal operation of the product  brought  near the product     The information in this publication has been carefully checked and is believed to be  entirely accurate at the time of publication  HUVITZ assumes no responsibility   however  for possible errors or omissions  or for any consequences resulting from    the use of the information contained herein     HUVITZ reserves the right to make changes in its products or product specifications  at any time without prior notice and is not required to update this documentation to  reflect such changes       2005   2013 HUVITZ Co   Ltd   689 3  Geumjeong dong  Gunpo si  Gyeonggi do   435 862  Republic of Korea    All rights are reserved   Under copyright laws  this manual may not be copied  in whole or in part  without the  prior written consent of HUVITZ Co   Ltd        CFR 4000 Operator   s Manual 3    Contents    IMPORTANT NOTICE sasssdssvecssatissevsctivassessasvasachuctvavssuntasveseoavavesuetasvesegteavesws  LT ANUP OAUCHON E                        1 1 System Configuration                sscccsssssccsssssrcssscsccssssessssccesssscsesss
7. SUB crossed serial cable       Connect a barcode reader to the EDGER2 port  barcode reader should have a    connector for external power adaptor     Connect a power adaptor to the barcode reader      Turn on the Frame Reader      Cable connection          ZNNOTE       n case of using a barcode scanner  it should be one with external power       Source as the frame reader doesn t supply power through the port              CFR 4000 Operator   s Manual 25    7 3 DCS Options of Frame Reader    To access the DCS options in the menu mode  at least one of EDGER 1 and  EDGER 2 port should be set for DCS       Procedure for Menu Execution       Press MENU button and select the    CONFIG    menu   gt  Refer to the section 6 1 for menu operation     Set at least one of EDGER 1 and EDGER 2 port like bellows    EDGER 1 2   PC    PROTO 1 2   DCS or DCS_Z     Change the menu category to DCS  if either of the edger port is set for DCS  the  DCS menu category is activated       DCS Parameters                               Name Description Option List  M ID Machine Id 00   99  TIMEOUT Timeout interval for communication 10   90 seconds  DATA PT Data points for DCS output   400    500    800    1000    1200    1440  FORMAT Data format for DCS output    ASCII ABS    ASCII ABS   ASCII Absolute    BIN ABS    BIN ABS   Binary Absolute    BIN DIF    BIN DIF   Binary Differential    PACKED BIN    PACKED BIN   Packed Binary  ANGLE Angle type for DCS output   EVEN    UNEVEN       26 CFR 4000 Operator   
8. ater  splashes  dripping water  or sprayed water  Do not place containers containing  fluids  liquids  or gases on top of any electrical equipment or devices     The equipment must be operated only by  or under direct supervision of a    properly trained and qualified person     The service technician of Huvitz or the technician authorized by Huvitz may only  carry out modifications of this equipment     Customer maintenance of this equipment may only be performed as stated in the  User   s Manual and Service Manual  Any additional maintenance may only be  performed by the service technician of Huvitz or the technician authorized by    Huvitz     The manufacturer is only responsible for effects on safety  reliability  and  performance of this equipment when the following requirements are fulfilled   1   The electrical installation in the respective room corresponds to the specifications  stated in this manual and  2  This equipment is used  operated  and maintained  according to this manual and Service Manual     The manufacturer is not liable for damage caused by unauthorized tampering  with the device s   Such tampering will forfeit any right to claim under warranty     This equipment may only be used together with accessories supplied by Huvitz   If the customer makes use of other accessories  use them only if their safe  usability under technical aspect has been proved and confirmed by Huvitz or the    manufacturer of the accessory              CFR 4000 Operator s Manual 
9. dn mA m n n la NM EIN M m M Mim m MUR M M MR M M NUR E RCM MTM CM ace 1  Fuse 3  1 5A  tinh ara wi a aa n wan aki RR n O  d ae KM a a R37 2  Power Cable  Frame Reader  Serre NN AH MCA UMOR OR RT RR T TOR U UNA URAN kuse rr 1  Option  Barcode Scanner Petr TTT TT Ter Cree n A ree re TT eT re reer K O K ee ee eee 1  9 pin Dsub Serial Cable  Crossed   TIPP 1  Lens Adapter dium din m iu mM aT M M RR MTM M M M M a M M M m CM  MTM M M M M B E d m M NN mw C UR RN l  M RR  MD n 3  Specification  Frame Reader   Dimension 280 W  x 300 D  x 230 H  mm   Tracing System 3D Binocular   Weight 8kg   Power Supply AC 100 240V  50 60Hz   Power Consumption 42W  Maximum           System Dimension                                                                295    
10. eter Value    f BEEP  O    Executed B  Parameter B  Save  amp  Return  Name      R  L button  changing the value of the executed parameter      B button  saving the change for the executed parameter and return to the menu    CFR 4000 Operator   s Manual 21      STOP button  canceling the execution and return to the menu      Configuration Parameters                                     Name Description Option List  BEEP Buzzer activation   ON    OFF  FRAME Default frame material   METAL    PL HARD    PL SOFT  EDGER 1 Target device for EDGER 1 port   EDGER    Selecting  NONE  disable the port  PC    NONE  PROTO 1 Data communication protocol for     HUVITZ  EDGER 1 port   DCS    DOS Z  BPS 1 Baud rate for EDGER  1 port   115200    38400    9600    14400    19200    57600  EDGER 2 Target device for EDGER 2 port   EDGER    Selecting  NONE  disable the port   PC    BARCODE    NONE  PROTO 2 Data communication protocol for  EDGER 2 port Same as    PROTO 1     BPS 2 Baud rate for EDGER  2 port Same as BPS 1           22  CFR 4000 Operator   s Manual    6 2 User Preferences of Frame Reader      Refer to 6 1 for operating the Menu Mode      User Preference Parameters                                           Name Description Option List  ID INFO Product identification  VERSION Software version number  DBL Bridge size input option for tracing     YES  single side   NO  SEMI AT Prompt option SEMI AUTO tracing     YES  mode   NO  MINI FR Low speed tracing option for frames     YES  with mi
11. frame or pattern  tracing Scanner ready        METAL       Tracer beeps and prompts to    scan a barcode Scan job no   STOP  Cancel       Scan a barcode and itl    display the number for a Job no  scanned       123456789012  Second on the screen       Frame tracing is automatically  started after the job number    input          The job number is transmitted  with the shape data through  the EDGER 1 port                   The job number scanned by the barcode reader is recognized by the target device  which is connected to the  EDGER 1  port with the protocol DCS or the DCS Z     28 CFR 4000 Operator   s Manual    8  System Maintenance  8 1 Automatic Calibration of Frame Reader    The Frame Reader requires calibration in following cases       Traced shape is off axis     Traced shape has smaller or bigger size     Stylus tip is not locating the frame groove properly     Frame Reader issues height or dimension error for frames or patterns  especially  when it seems that the mechanical stroke is enough for a frame or a pattern    Automatic calibration for frame reader consists of three parts  Stroke  Frame  Pattern   In case of any change happened in the stylus  do the full calibration in the following    Sequence       Stroke calibration    Frame calibration      Pattern calibration    Otherwise  just perform frame or pattern calibration correspondingly     Frame Calibration      Purpose    Detecting the frame reading position  axis  and calibrating the size       Procedure   
12. g  not the cord                    Avoid places where the ambient temperature falls below 10  C or exceeds 40  C for  normal operation  or below    20 C or exceeds 85  C for transportation and storage   Humidity should be maintained between 50  and 80  for normal operation   transportation and storage  Avoid environments where the equipment is exposed to    excessive shocks or vibrations  And also the normal operation time is as following     Operation time  short term operation max 6min    2 4 Safety Precautions    This equipment has been developed and tested according to safety standards as  well as national and international standards  This guarantees a very high degree of  safety for this device  The legislator expects us inform the user expressively about  the safety aspects in dealing with the device  The correct handling of this equipment  is imperative for its safe operation  Therefore  please read carefully all instructions  before switching on this device  For more detailed information  please contact our    Customer Service Department or one of our authorized representatives        This equipment must not be used  a  in an area that is in danger of explosions    10    CFR 4000 Operator   s Manual    and  b  in the presence of flammable  explosive  or volatile solvent such as    alcohol  benzene or similar chemicals     Do not put or use this device in humid rooms  Humidity should be maintained  between 50  and 80  for normal operation  Do not expose the device to w
13. g Bar  Gripper    Stylus    Rear View    Main Switch Power Inlet  amp  Fuse Holder       Interface Terminals      EDGER 1     EDGER 2     PC  upgrade console     EXTRA  reserved     CFR 4000 Operator   s Manual 15    3 2 Standard Accessory      e   t    4     y    a      Standard Frame Standard Pattern Pattern Holder     amp     16 CFR 4000 Operator   s Manual    4  Installation Procedure    Install a Frame Reader in a sequence below           Remove the shock absorbing material from the package box and pull out the  Frame Reader carefully     Remove the shock absorbing material from the workspace of Stylus     Plug the Power Cable into the power inlet at the back of the product and turn on  the power to check the initial operation     If the initial operation works properly  turn off the instrument     Connect Edger and Frame Reader by using a 9 pin D sub Crossed Interface    Cable and make sure the connectors are fixed firmly by tightening the scre    ws in the cable connector     5  Operation    Control Panel    Scanner ready        METAL       Menu    Menu Selection      CONFIG  System Configuration   Refer to the section 6 1    Configuration of Frame Reader      CALIB  Automatic Calibration       Refer to the section 7 1 Automatic    Calibration of Frame Reader      ETC  User Preferences   Refer to the section 6 2 User    Preferences of Frame Reader    CFR 4000 Operator s Manual 17    Frame    Selection of Frame Material      METAL    PL HARD  Hard Plastic     PL SOFT  S
14. irable to place the frame so that the    center of the frame bridge is aligned with the center mark of the gripping bar     CFR 4000 Operator   s Manual 19       Press the FRAME button to select a frame material among METAL  PL HARD   and PL SOFT     Press areading button  B for both sides  R for the right  and L for the left                 Pattern    Pattern Tracing  Demo Lens    Mark the horizontal axis on a  pattern or a demo lens and attach  a lens adapter on the axis by       Pattern  Fixing  Screw    using a blocker      Put the blocked pattern to the  Pattern Holder      Press the FRAME button to select a tracing mode between LO CURV and HI  CURV      Press areading button  R for the right side  and L for the left     Lens Adapter    Center  Mark           Loading the Pattern Holder      20 CFR 4000 Operator   s Manual    6  User Defined Options  6 1 Configuration of Frame Reader      Operating the Menu Mode    Scanner ready        METAL         Press the MENU button and then B button to enter the menu mode    Press the STOP button over 2 seconds to exit the menu mode    Parameter Name        LEFT NN GOTH   RIGHT    Menu Category    ALEJ B  Name      MENU button  changing the selection of menu category   gt  Holding down the button for 2 seconds reverses the selection     FRAME button  selecting a configuration parameter in a menu category   gt  Holding down the button for 2 seconds reverse the selection     B button  executing a selected parameter for change    Param
15. ng the Remote Tracing FUN ction             cccccsssscsssssssssssssssssssssssssessseees 23    7 1 Interface Specification                              ecce eee eese eee e eerte eee eeene sees 29    7 2 Connecting to a DCS host                     eeeeeeeeeeeeeeeeee eee eene eneseeneees 29    4 CFR 4000 Operator   s Manual    7 3 DCS Options of Frame Reader                 ccccccccssssscssssseessscssesssssseeees Z    7 4 Using the Barcode Interface for Inputting Job Number                   26  6  System Maintenance               eere eese eee eee eene eee einen een ee een netten sete tenes teen 28  8 1 Automatic Calibration of Frame Reader                                          28  BGUIIOEUPAGUGONSURB          ee e eo eee eoe erneuern neon oue rano terno aeterno ee toan une 00   32    oo 0 Coo REESOODUEODUIODUDODODODL DUREE 32    onam Diem M                   32    CFR 4000 Operator   s Manual 5    1  Introduction    1 1 System Configuration    Frame Reader  CFR 4000   DCS Host  PC     1 2 Main Features    Binocular 3 dimensional tracing of frames guaranteeing more precision in frame    fitting     Tracing of a demo lens or a pattern executes in two different modes  HI and LO   Especially the HI mode compensates the size by the tilting angle of the demo lens    or the pattern     SEMI AUTO tracing mode is additionally provided for manual handling of the    stylus position into the frame groove especially when the groove is lopsided     Barcode scanner interface is supported
16. nimal vertical size   NO  FPD OFF FPD offset  2 99    2 99  JOB NO  Job number reset option    Turning on the option keep the last job  number even after turning off the power and d  the last job number is continued next time FAS  it s turned on  TRANSMT Data transmission option for when  both the edger 1 and 2 ports are  turned on   AUTO    AUTO option transmits automatically   USER    USER option transmits through user selecting  output port  EXIT Exits the menu mode          CFR 4000 Operator   s Manual 23    7  Using the Remote Tracing Function    7 1 Interface Specification    Version Information      Frame Reader with V1 70 or newer is required    Compatible with DCS V3 07 or its compliances    RS232C Interface    The basic specification of the communication port of the Frame Reader for  interfacing PC follows the information below       Baud Rate  115200  57600  38400  19200  14400 or 9600    Data Bit  8     Stop Bit  1     Parity  None     Flow control  None    Data Format      Format  ASCII Absolute  Binary Absolute  Binary Differential  Packed Binary    Data Points  1440  1200  1000  800  500  400     Radius mode  Even  Uneven     Side  Both  Right  Left     Tracing Type  Frame  Pattern    7 2 Connecting to a DCS host    Before connecting the Frame Reader to any PC which is running a lab management    Software or a host program on it  make it sure to turn the instrument off     24 CFR 4000 Operator s Manual      Procedure     Connect PC to EDGER1 port with a 9 pin D
17. oft or flexible Plastic     Before tracing a frame  choose one of the  material types  Usually this information is  used by the edger for such as predefined  size adjustment     Selection of Pattern Tracing Mode      LO CURV  2D Tracing     HI CURV  3D Tracing     When the Pattern Holder is loaded in the  Frame Reader  it automatically recognizes  the pattern tracing mode  Hl CURV mode  traces a pattern or a demo lens with size    adjustment by the tilted angle of the pattern        f the tracing demo lens is curved highly  using the    HI CURV mode guarantees more precision in    size     18 CFR 4000 Operator   s Manual       LEFT   BOTH   RIGHT      BOTH   for tracing both sides of a frame and not for a demo lens    R   for tracing right side of a frame or a right hand demo lens     L   for tracing left side of a frame or a left hand demo lens       When it s for a frame  holding down a tracing button for 2 seconds will executes the SEMI AUTO  tracing mode which is to aid tracing a frame with its frame groove lopsided by allowing the operator    position the stylus in the center of the groove for normal tracing        Operation Tips      SEMI AUTO mode has effect on frame tracing only          SEMI AUTO mode traces a frame slower than normal tracing mode for safe                tracing   LEFT     RIGHT  B  Continue   SEMI   METAL    MC     STOP DEN      Frame Tracing       Place a frame between the upper and the lower grippers     In case of rather curved frames  it   s des
18. s Manual                   FR SIZE Size offset of frame data for DCS    i  9 99    9 99  output  in terms of circumference   PT SIZE Size offset of pattern data for DCS       9 99    9 99  output  in terms of circumference   MIRROR Mirroring option for DCS output when     YES  single side is traced   NO  FRAME Default frame material for a job for  DCS output   METAL    METAL   Metal   PL HARD    PL HARD   Hard Plastic   PL SOFT    PL SOFT   Soft Plastic   UNDEFIN    UNDEFIN   Undefined   OFF    OFF   Do not output frame material info                 7 4 Using the Barcode Interface for Inputting Job Number    CFR 4000 with version 1 68 or newer supports barcode scanning through the   EDGER 2 port    by setting the    EDGER 2    option to    BARCODE     But it s required to  supply power separately to the barcode reader as the EDGER 2 port is not designed  to supply power through it  This allows it to assign a job number for a new tracing  job  Go to the  CONFIG  menu and set the options like below       Options for the EDGER 2 port as a barcode interface    EDGER 2  BARCODE    PROTO 2  N A    BPS 2  9600  depending on the setting of a barcode scanner       Setup for Barcode Scanner      Baud rate  9600  or what else bps that can be matched with the BPS 2 option in  the Frame Reader     CFR 4000 Operator   s Manual 27      Termination code    CR     lt LF gt  or  lt CR gt  lt LF gt       Inputting sequence of Job Number with a barcode scanner       Press a button to execute    
19. ssesees  1 2 Main Features            ccsssssssssssssssssssssssssccssssssssssscsccsssssscssssssssssssssssssees    1 3 ClassifiCatiOn       5 oer eee e eee eee ee e ee eoo e e eo e eo a eoe e e e euo eee eee eae euo    2   5   5   5   5   2  Safety INfOrmaliOnsccrccaccccsscaccecssdaccdsarsaccecsedeccseraceesschacecsdebaccesscaaceesavacceosteas D   2 1 Introduction                         eee e e eee ecce eese eese eene seen esse sens esee sse sesssseseesss O  2 2 Safety Symbols                      1 e eeeeee eee eese esten esee eene eee ono esee ssseseseeseseeees 7  2 3 Environment factors                     eee ecce eee eee eee eee eren enses esee eens eso senssseesos S  2 4 Safety Precautions                      ecce e ecce eee eee etes eee eren esses ese esesseseessssseesss D   3  System Configuration                     eee esee esee eee eene eene eee eennseeeeenneeee  LF  3 1 Frame Reader             ee eeveee te etn ea een nea eria oua ede vase erae oe eee saea ste essvese 14  3 2 Standard Accessory                      cease eee ee eee eese ee eene see eese sees eeseseesssseeees LO   4  Installation Procedure                        eee esee eee eene eee nn eeeennneeeeene  LO  De  2I EP 1D  6  User Defined Options         cccsssscscsssssssssssscsssssscsssscecssssscscssssssssssssssesssesees 20  6 1 Configuration of Frame Reader                               eeeeeeeeeeeeeeeeeeeeee  20  6 2 User Preferences of Frame Reader                                eese  22   7  Usi
20. us hurt during the operation or cause the malfunction of the  product     The product should be properly installed and maintained at the horizontally    leveled place  Otherwise  it may affect the normal operation of the product     Do not force on the stylus of frame reader  It may cause the malfunction of the    product     Be sure that the stylus of frame reader is not interfered with the human body or  other objects during the operation  Otherwise  it may cause the hurt or  malfunction of the product           Z N CAUTION          When moving the equipment  first fix the stage and check whether the power    supply is off     In case of setting down the equipment  make sure not to be interfered with the  obstacles  Setting down the product slowly in order to prevent the hurt of human  body or damage to the product     When moving the equipment  make sure the locking device and the screw for    the cover are properly tightened     In case of packaging the equipment  use the recommended packaging material  and method in order to prevent the damage during the transportation           CFR 4000 Operator   s Manual 13       ZN CAUTION            Be sure to use the standard accessories or tools provided together with the  product for the maintenance  Otherwise  it may cause the malfunction of the  product           14 CFR 4000 Operator   s Manual    3  System Configuration  3 1 Frame Reader    Front View    Workspace for Stylus           Display Window    Control Panel    Grippin
21. will help  prevent potential negative consequences for the  environment and human health    4  For more detailed information about disposal of your  old appliance  please contact your city office  waste  disposal service or the shop where you purchased the  product     Ix                8    CFR 4000 Operator   s Manual    2 3 Environment factors    Avoid the following environments for operation or storage        Where the equipment is exposed to water vapor   Don   t operate the equipment with a wet hand        Where the temperature changes extremely     Operation Temperature  10   40  C   Humidity  50   80      Storage Temperature   20   85  C  Humidity  50   80         Where the humidity is extremely high or there is a ventilation  problem        Where equipment is exposed to chemical material or  explosive gas     Where the equipment is exposed to direct sunlight        Where it is near the heat equipment        Don   t disassemble the product or open  We aren t  responsible for it for nothing                 Don   t plug the AC power cord into the outlet before the  connection between devices of the equipment is  completed  This can generate the defect           CFR 4000 Operator   s Manual 9       Where the equipment is subject to excessive shocks or       vibrations        Be careful not to be inserted dust  especially  metal       Be careful not to close the fan located on the lateral or  backside of the equipment           Pull out the power cord with holding the plu
    
Download Pdf Manuals
 
 
    