        Sun Fire 6800/4810/4800/3800 Systems Firmware 5.12.7 Release
         Contents
1.      18 Sun Fire 6800 4810 4800 3800 Systems Firmware 5 12 7 Release Notes   August 2002    Domain Hangs on Firmware Downgrade to 5 12 x  or 5 11 x  BugID 4719404     Downgrading from 5 13 0  5 13 1 or 5 13 2 firmware to any version of 5 12 or 5 11  firmware causes the domain to hang  For 5 13 0  5 13 1 and 5 13 2 firmware  the  default setting of the variable use new ioadd map is true  for 5 12 and 5 11  firmware  the setting must be false     Workaround  Before attempting to bring up the domain  execute the setdefaults  command in a shell on the platform to reset the variable        Dynamic Reconfiguration on Sun Fire  6800 4810 4800 3800 Systems    This section provides general information on using dynamic reconfiguration  DR  on  Sun Fire 6800  4810  4800  and 3800 systems     System Specific DR Support    System specific DR support on the 6800 4810 4800 3800 systems is shown by the  cfgadm command  System boards are indicated as class    sbd     CompactPCI  cPCI   cards are shown as class    pci     Users of DR through the cfgadm interface will see  other DR classes as well     For more information about system specific problems with DR  see the    Dynamic  Reconfiguration  DR  Software Bugs    on page 24     To view the classes that are associated with attachment points  run the following  command as superuser          cfgadm  s    cols ap_id class                Dynamic attachment points may also be listed by using the cfgadm command with  its  a option  To determine t
2.    etc hostname  interface  where  interface is a value such as hmel or qfe2      This triggers the in mpathd daemon to resume probing and detect repairs   Consequently  in mpathd causes original IP addresses to failback to this interface   The interface should now be online and ready for use under IPMP        Note     If the interface had not been unplumbed and set to the OFFLINE status prior  to a previous detach  then the attach operation described here would not  automatically configure it  To set the interface back to the ONLINE status and  failback its IP address after the physical attach is complete  enter the following  command    if mpadm  r interface     Operating System Quiescence    This section discusses permanent memory  and the requirement to quiesce the  operating system when unconfiguring a system board that has permanent memory     A quick way to determine whether a board has permanent memory is to run the  following command as superuser          cfgadm  av   grep permanent             The system responds with output such as the following  which describes system  board 0  zero      NO SBO  memory connected configured ok base address 0x0   4194304 KBytes total  668072 KBytes permanent    Permanent memory is where the Solaris kernel and its data reside  The kernel cannot  be released from memory in the same way that user processes residing in other  boards can release memory by paging out to the swap device  Instead  cfgadm uses  the copy rename technique to r
3.   caract  res  est prot  g   par un copyright et licenci   par des fournisseurs de Sun     Des parties de ce produit pourront   tre d  riv  es des syst  mes Berkeley BSD licenci  s par l   Universit   de Californie  UNIX est une marque  d  pos  e aux Etats Unis et dans d   autres pays et licenci  e exclusivement par X Open Company  Ltd     Sun  Sun Microsystems  le logo Sun  AnswerBook2  docs sun com  OpenBoot  Sun Fire  Sun StorEdge  et Solaris sont des marques de fabrique  ou des marques d  pos  es  ou marques de service  de Sun Microsystems  Inc  aux Etats Unis et dans d   autres pays  Toutes les marques SPARC  sont utilis  es sous licence et sont des marques de fabrique ou des marques d  pos  es de SPARC International  Inc  aux Etats Unis et dans  d   autres pays  Les produits portant les marques SPARC sont bas  s sur une architecture d  velopp  e par Sun Microsystems  Inc     L interface d utilisation graphique OPEN LOOK et Sun    a   t   d  velopp  e par Sun Microsystems  Inc  pour ses utilisateurs et licenci  s  Sun  reconna  t les efforts de pionniers de Xerox pour la recherche et le d  veloppement du concept des interfaces d utilisation visuelle ou graphique  pour l   industrie de l informatique  Sun d  tient une licence non exclusive de Xerox sur l interface d utilisation graphique Xerox  cette licence  couvrant   galement les licenci  s de Sun qui mettent en place l interface d utilisation graphique OPEN LOOK et qui en outre se conforment aux  licences   crites de 
4.  Domain A Is Completely Off  showkey  Shows Domain A State Going From off To on   Bug ID 4513961     This situation occurs when you run the dumpconfig command when a domain is  turned on  When you run restoreconfig  the transitional keyswitch position is  written to NVCI     Workaround  Do not run the dumpconfig command when starting up or shutting  down a domain     SC Upgrade Gives a Decompress Error After a  Reboot To Any Domain  Bug ID 4593208     After the firmware is upgraded  a decompress error occurs when a domain is  rebooted     Workaround  To prevent this error  follow the    Firmware Upgrade Procedure    on  page 8 when you are updating the firmware     If you did not follow this procedure and you encounter this error  run the following  command on the system controller in the platform shell     schostname SC gt  setkeyswitch  d domainID off    flashupdate  c and flashupdate  u  Incorrectly Copy Firmware Images Between  Boards  Bug ID 4638200     Using flashupdate  c or flashupdate  u to update a board after it has  passed POST and been put into OBP mode fails  though some messages incorrectly  indicate that the update succeeded        Workaround  To prevent the problem  flash the board prior to running POST and  placing the board in OBP mode  To correct the problem  reflash the board from an  FTP source  Service providers can also clear the problem by powering the board off   physically removing it from the system  reinserting it  then powering the board back  on
5.  Domains    in  Chapter 4 has been revised as follows     6  If you did not set up two partitions and if the board that you plan to assign to  a new domain is currently used by domain A  shut down domain A or use DR  to unconfigure and disconnect the board out of the domain     Assigning and Unassigning Boards    When you assign a board to a domain by using the addboard command from the  domain shell  the board cannot be used by another domain and must be listed in the  Access Control List  ACL  for the domain  If the board is assigned to a domain when  the domain is active  the board is not configured to be part of that domain     m For an overview of steps on assigning and unassigning boards to or from a  domain with and without DR  see TABLE 1 and TABLE 2     m For complete step by step procedures that do not use DR  refer to the procedures     To Assign a Board to a Domain    and    To Unassign a Board to a Domain    in  Chapter 6  Maintenance  of the Sun Fire 6800 4810 4800 3800 Systems Platform  Administration Manual     a For procedures that use DR  refer to the Sun Fire 6800  4810  4800  and 3800  Systems Dynamic Reconfiguration User Guide     Firmware Release Notes 3    TABLE1 Overview of Steps to Assign a Board To a Domain       To Assign a Board To a Domain Using DR    To Assign a Board To a Domain Not Using DR    1  Assign the disconnected and isolated board to the    domain with the cfgadm  x assign command   2  Use DR to configure the board into the domain    Re
6.  O assemblies  If the firmware for  your CPU Memory boards and I O assemblies is different from the system  controller firmware  you may not be able to boot your domains        1  Connect to the system controller console  serial port  to monitor the system when  you upgrade the firmware  Step 6      The prompt for the system controller is    schostname   SC gt     2  Shut down all the domains by halting the Solaris operating environment        3  In each domain shell that has an active domain  set the keyswitch position to  standby        schostname A gt  setkeyswitch standby             Sun Fire 6800 4810 4800 3800 Systems Firmware 5 12 7 Release Notes   August 2002    4  Verify that all the CPU Memory boards and I O assemblies are powered on by  running the showboards command on the system controller in the platform shell     schostname SC gt  showboards    5  If any CPU Memory boards or I O assemblies are not powered on  use the  poweron command on the system controller in the platform shell to power on  those components     schostname SC gt  poweron component_names    6  Upgrade the firmware by using the flashupdate command on the system  controller in the platform shell     Caution     Do not power down the system or reset the system while performing this  step        Use the command syntax appropriate to the URL protocol     schostname SC gt  flashupdate  f URL all    The flashupdate command reboots the system controller and upgrades the  CPU Memory boards and I O assem
7.  host ID and MAC address based on which  physical domain is in use  A  B  and so forth  can prevent host licensed software from  running  In situations where a hardware failure would require changing domains   host licensed software will refuse to start     Workaround  It may be possible to reconfigure the system hardware to support the  required domain  Contact your service provider for assistance     showdomain Contains FrameManager  Information  Bug ID 4492564     FrameManager information should not be presented in the output from the  showdomain command     Workaround  Ignore the FrameManager information      SIGBUS 10  bus error  Causing Hang  While  Running disablecomponent or  enablecomponent  Bug ID 4492914     When you add or remove a component from the blacklist or when you power on or  power off system boards from multiple system controller connections  the  commands related to system board operations can sometimes hang     Workaround  Avoid running commands that show the system state at the same time  the state is being changed  However  if you are running a command related to  system board operations that hangs  reboot the system controller     Domain Is Powered Off During  showreset state  Bug ID 4496769     Workaround  Turn on the domain by running the setkeyswitch on command at  the domain shell     Firmware Release Notes 15    dumpconfig Responds With  could not  access required file   Bug ID 4497581     When you run dumpconfig to save platform and domain con
8.  install SBM on systems that will be used for DR trials  and do  not perform CPU system board DR operations on systems with SBM installed     26 Sun Fire 6800 4810 4800 3800 Systems Firmware 5 12 7 Release Notes   August 2002    DR Hangs During a Configure Operation On an  I O Board When the vxdmpadm Policy Is Set to  check_all  Bug ID 4509462     A DR configure operation hangs with an IBx  I O board  after a few successful  iterations  this occurs when the DR operation is executed concurrently with the DMP  daemon that is implementing the policy    check_all    with a time interval     Workaround  To avoid the deadlock between the DMP daemon and system board  DR  enter the following command to stop and re start the DMP daemon before  performing DR operations        usr sbin vxdmpadm stop restore       Firmware Release Notes 27    28 Sun Fire 6800 4810 4800 3800 Systems Firmware 5 12 7 Release Notes   August 2002    
9.  the    Firmware Upgrade Procedure    on page 8        20 Sun Fire 6800 4810 4800 3800 Systems Firmware 5 12 7 Release Notes   August 2002    Known DR Limitations    This section contains known DR software limitations of the Sun Fire 6800  4810  4800   and 3800 systems     If you add a system board to a domain without using DR procedures  such as by  running the addboard command line interface  CLI  command on the system  controller  SC   you must run the setkeyswitch off command and then the  setkeyswitch on command to bring the board into the system     The DR software does not support MPxIO  also referred to as the Sun StorEdge     Traffic Manager  for the Solaris 8 2 02 operating environment     Before performing any DR operation on an I O  IBx  board  enter the following  command to stop the vold daemon       sh  etc init d volmgt stop    After the DR operation has successfully completed  enter the following command  to re start the vold daemon             sh  etc init d volmgt start          On Sun Fire 6800  4810  4800  and 3800 systems  DR does not support HIPPI P   bug 4445932   nor SAI P  bug 4466378   nor the hsi p driver  bug 4496362      You must execute the devfsadm 1M  command in order to see any changes that  have been made  especially in regard to changes from PCI to cPCI     Do not reboot nor reset the System Controller  SC  during DR operations  In  addition  do not perform a flashupdate  which requires a reboot upon completion     Limitations Specific to C
10. Qe Sun    microsystems    Sun Fire    6800 4810 4800 3800  Systems Firmware 5 12 7  Release Notes       Sun Microsystems  Inc    4150 Network Circle   Santa Clara  CA 95054 U S A   650 960 1300    Part No  816 7721 10  August 2002  Revision A    Send comments about this document to  docfeedback sun com    Copyright 2001  2002 Sun Microsystems  Inc   4150 Network Circle  Santa Clara  CA 95054 U S A  All rights reserved     This product or document is distributed under licenses restricting its use  copying  distribution  and decompilation  No part of this product or  document may be reproduced in any form by any means without prior written authorization of Sun and its licensors  if any  Third party  software  including font technology  is copyrighted and licensed from Sun suppliers     Parts of the product may be derived from Berkeley BSD systems  licensed from the University of California  UNIX is a registered trademark in  the U S  and other countries  exclusively licensed through X Open Company  Ltd     Sun  Sun Microsystems  the Sun logo  AnswerBook2  docs sun com  Java  OpenBoot  Sun Fire  Sun StorEdge and Solaris are trademarks   registered trademarks  or service marks of Sun Microsystems  Inc  in the U S  and other countries  All SPARC trademarks are used under license  and are trademarks or registered trademarks of SPARC International  Inc  in the U S  and other countries  Products bearing SPARC trademarks  are based upon an architecture developed by Sun Microsystems  I
11. Sun     Achats f  d  raux   logiciel commercial   Les utilisateurs gouvernementaux doivent respecter les conditions du contrat de licence standard     LA DOCUMENTATION EST FOURNIE    EN L ETAT    ET TOUTES AUTRES CONDITIONS  DECLARATIONS ET GARANTIES EXPRESSES  OU TACITES SONT FORMELLEMENT EXCLUES  DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE  Y COMPRIS NOTAMMENT  TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE  A L APTITUDE A UNE UTILISATION PARTICULIERE OU A  L ABSENCE DE CONTREFA  ON      gt  Please 4    8 Recycle    es Adobe PostScript    Firmware Release Notes       This document contains information about Sun Fire    6800 4810  4800  3800  Systems Firmware Release 5 12 7        Note     Either this firmware release or release 5 13 2 is mandatory for Sun Fire  6800 4810 4800 3800 servers  These firmware releases introduce JTAG support for  the UltraSPARC II      Cu  900MHz CPU Memory Board  Earlier versions of 5 12  and 5 13 firmware are not compatible with Cheetah 2 3 based x options  FRUs  or  servers        The previous release of 5 12 firmware  5 12 6  introduced Dynamic Reconfiguration   DR  functionality to these Sun Fire servers  For the convienience of customers  upgrading to 5 12 7 from a release other than 5 12 6  these Release Notes contain the  same information as 5 12 6  except for this introduction  and the add description of  BugID 4638200 in Known Limitations  Minor modifications also appear in other  places  where appropriate    This document 
12. blies  scapp  and RTOS     Note     When running scapp 5 12 5 or higher and RTOS 18 or higher  the  upgrade procedure updates scapp and RTOS only when the image to be installed is  different from the image currently installed        7  After the system controller reboots successfully  connect to each domain console  and power off all the CPU Memory boards and I O assemblies by setting the  keyswitch position to off        schostname A gt  setkeyswitch off             8  Verify that all the CPU Memory boards and I O assemblies are powered off by  running the showboards command on the system controller in the platform shell        schostname SC gt  showboards             Firmware Release Notes 9    9  If any CPU Memory boards or I O assemblies are not powered off  use the  poweroff command on the system controller in the platform shell to power off  those components     schostname   SC gt  poweroff component_names    10  Bring up each domain by setting the keyswitch position to on     schostname A gt  setkeyswitch on    11  After all the domains have been brought up  update the configuration backup of  the system controller by using the dumpconfig command     schostname SC gt  dumpconfig  f URL    where URL specifies the ftp protocol        Caution     If you downgrade from 5 13 0  5 13 1 or 5 13 2 firmware to any version of  5 12 firmware  you must execute the setdefaults command before attempting to  bring up the domain  or the domain may hang        Firmware On Replacement B
13. contains the following sections    m General Issues    a Dynamic Reconfiguration Information in the Sun Fire 6800 4810 4800 3800  Systems Platform Administration Manual    a Using FTP URLs  a Firmware Upgrade Procedure  a Firmware On Replacement Boards and Assemblies  a System Controller Command Changes  a Modified Commands      New Command Options Parameters  m Known Sun Fire 6800 4810 4800 3800 System Limitations  a Dynamic Reconfiguration on Sun Fire 6800 4810 4800 3800 Systems    System Specific DR Support    a Dynamic Reconfiguration Software Installation Instructions  a Known DR Limitations    a Dynamic Reconfiguration  DR  Software Bugs       General Issues    Dynamic Reconfiguration Information in the Sun  Fire 6800 4810 4800 3800 Systems Platform  Administration Manual    The following sections provide basic Dynamic Reconfiguration  DR  information  that was not included in the Sun Fire 6800 4810 4800 3800 Systems Platform  Administration Manual for the 5 12 6 release     m Dynamic Reconfiguration Overview   m Before Creating Multiple Domains   m Assigning and Unassigning Boards   a CPU Memory Boards and I O Assemblies    Dynamic Reconfiguration Overview    Dynamic Reconfiguration  DR   which is provided as part of the Solaris operating  environment  enables you to safely add and remove CPU Memory boards and I O  assemblies while the system is still running  DR controls the software aspects of  dynamically changing the hardware used by a domain  with minimal disrupti
14. ct usage of the disablecomponent command     Single I O Assembly Failure Causes Boot Failure   Bug ID 4502247     The I O assemblies are not capable of being tested in isolation  Because of this  the  failures that become visible when I O POST runs will stop the whole boot process  because they pause the domain in hardware     Workaround  Remove the failed I O assembly from the domain with deleteboard   Turn the keyswitch on with setkeyswitch on to reboot without the failed board   Refer to the Sun Fire 6800 4810 4800 3800 System Controller Command Reference  Manual for correct usage of the deleteboard command     restoreconfig Using Incompatible Firmware  Hangs The System Controller  Bug ID 4504322     Workaround  Do not try to restore  using restoreconfig  the configuration file of  the current firmware on a system which has older firmware  This will hang the  system  Restore the configuration manually from the system controller platform and  domain shells as well as OBP     setk  d  domain  From Platform Shell Requires  off To Be Typed in Full  Bug ID 4508770     If you use the setkeyswitch command to turn a domain off from the platform  shell  you must type the word off with the command instead of using the  abbreviation of  However  the setkeyswitch of command is recognized as a valid  command string when it is run on the domain shell     Workaround  Type off rather than of when you run the setkeyswitch command  on the platform shell     Firmware Release Notes 17    When
15. e  Sun Fire 6800 4810 4800 3800 System Controller Command Reference Manual     m If you have an I O assembly of the same type installed  use the  flashupdate  c command     schostname SC gt  flashupdate  c source_board destination_board    Go to Step 7        a If you do not have a I O assembly of the same type installed  use the  flashupdate  f command        schostname  SC gt  flashupdate  f URL board             6 Sun Fire 6800 4810 4800 3800 Systems Firmware 5 12 7 Release Notes   August 2002    6  Before you bring the board back to the Solaris operating environment  test the I O  assembly in a spare domain that contains at least one CPU Memory board with a  minimum of one CPU     a  Enter a spare domain     b  Test the I O assembly     See    To Test and I O assembly    in Chapter 7  Testing System Boards  in the Sun  Fire 6800 4810 4800 3800 Systems Platform Administration Manual     7  Use DR to connect and configure the assembly back into the domain running the  Solaris operating environment     Refer to the Sun Fire 6800  4810  4800  and 3800 Systems Dynamic Reconfiguration User  Guide     v To Move a Board Between Domains      To move a CPU Memory board or I O assembly between domains  complete the  DR procedures in the Sun Fire 6800  4810  4800  and 3800 Systems Dynamic  Reconfiguration User Guide     Y To Disconnect a Board Temporarily    If a CPU Memory board or I O assembly fails  you can use DR to power down the  board and leave it in the system until a replace
16. ed to a domain     Workaround  If a CPU Memory board is removed from the domain  restart  cryptorand by entering the following command as superuser       sh  etc init d cryptorand start       Firmware Release Notes 25    An SC ConsoleBus Error Appears While SNMP Is  Enabled and Running the DR Suite  Bug ID  4485505     A Console Bus Error message is occasionally generated during SNMP get  operations on the cpuModDescr object  This occurs infrequently  and only when the  SunManagement Center is being used to monitor a system  When it does occur      unknown    is returned to the Sun Management Center as the value of the  cpuModDescr object     Workaround  The only workaround is to not use the Sun Management Center   However  the message is harmless  and the problem occurs rarely  so it is safe simply  to ignore it  The only risk is that the Sun Management Center GUI may occasionally  display the wrong value for cpuModDescr     The cfgadm_sba Plugin in a Multi Threaded  Environment Does Not Function Properly  Bug ID  4498600     When a multi threaded client of the cfgadm library issues concurrent sbd requests   the system may hang     Workaround  None  Currently there are no existing applications implementing  multithreaded usage of the cfgadm library     SBM Can Cause a System Panic During DR  Operations  Bug ID 4506562     A panic may occur when a system board that contains CPUs is removed from the  system while Solaris Bandwidth Manager  SBM  is in use     Workaround  Do not
17. elease the memory     Firmware Release Notes 23    The first step in a copy rename operation is to stop all memory activity on the  system by pausing all I O operations and thread activity  this is known as quiescence   During quiescence the system is frozen and does not respond to external events such  as network packets  The duration of the quiescence depends on two factors  how  many I O devices and threads need to be stopped  and how much memory needs to  be copied  Typically the number of I O devices determines the required quiescent  time  because I O devices must be paused and unpaused  Typically  a quiescent state  lasts longer than two minutes     Because quiescence has a noticeable impact  cfgadm requests confirmation before  effecting quiescence  If you enter          cfgadm  c unconfigure NO SBO             The system responds with a prompt for confirmation   System may be temporarily suspended  proceed  yes no        If using Sun Management Center to perform the DR operation  a pop up window  displays this prompt      Enter Yes to confirm that the impact of the quiesce is acceptable  and to proceed        24    Dynamic Reconfiguration  DR  Software  Bugs    This section contains the Sun Bug ID numbers and synopses of the more important  bugs that have been discovered during testing of DR  This list does not include all  bugs     DR Operations Hang After a Few Iterations When  the CPU Power Control Is Also Running  Bug ID  4114317     When multiple concurrent DR o
18. fer to the Sun Fire 6800  4810  4800  and 3800   Systems Dynamic Reconfiguration User Guide     1  Assign the board to the domain with the  addboard command    2  Halt the Solaris operating environment in the  domain    3  Shut down the domain with setkeyswitch  standby     4  Turn on the domain with setkeyswitch on     TABLE2 Overview of Steps to Unassign a Board From a Domain       To Unassign a Board From a Domain Using DR    To Unassign a Board From a Domain Not Using DR    1  Use DR to unconfigure the board from the domain     Refer to the Sun Fire 6800  4810  4800  and 3800  Systems Dynamic Reconfiguration User Guide    2  Unassign the board from the domain with the  cfgadm  c disconnect  o unassign  command     1  Halt the Solaris operating environment in the  domain    2  Turn the keyswitch to standby mode with  setkeyswitch standby    3  Unassign the board from the domain with the  deleteboard command     4  Turn on the domain with setkeyswitch on     CPU Memory Boards and I O Assemblies    The following procedures describe the software steps needed to    a Hot swap a CPU Memory board or I O assembly    a Move a CPU Memory board or I O assembly between domains    a Disconnect a CPU Memory board or I O assembly temporarily    v To Hot Swap a CPU Memory Board    1  Use DR unconfigure and disconnect the CPU Memory board out of the domain   Refer to the Sun Fire 6800  4810  4800  and 3800 Systems Dynamic Reconfiguration User    Guide     2  Verify the state of the LEDs o
19. figurations  the  message could not access required file is displayed when one of the  following conditions exists     m The ftpd daemon for the host is disabled        m The IP address of the server is invalid     m An invalid FTP parameter was specified in the dumpconfig command     Workaround  Determine the correct FTP parameter or valid IP address  or enable the  ftpd daemon on the server     showboards  v Shows Incorrect Failover Status  Signals When Boards Are Off  Bug ID 4500126     Workaround  Boards should be powered on to know the    SCC1 signal    and     Failover    status     System Board With Failed Component Is Shown  As passed Not degraded  Bug ID 4500568     A missing  bad or incorrectly sized  DIMM in a memory bank causes that bank to  fail  but the output from the showboards command indicates that the board is a  passed board     Workaround  Check the status by using the showcomponent command     SYSTEM ERROR On Domain B While Performing  Parallel setkeyswitch on In A Single Partition   Bug ID 4500966     A CPU that fails POST might not be properly isolated from the domain  The domain  may crash as a result     16 Sun Fire 6800 4810 4800 3800 Systems Firmware 5 12 7 Release Notes   August 2002    Workaround  Disable the failed CPU with the disablecomponent command  Turn  the domain keyswitch off with setkeyswitch off and then turn it on with the  setkeyswitch on  Refer to the Sun Fire 6800 4810 4800 3800 System Controller  Command Reference Manual for corre
20. he class of a specific attachment point  add it as an  argument to the above command     Firmware Release Notes 19    Dynamic Reconfiguration Software Installation  Instructions    The following software supports DR on a Sun Fire system  Solaris 8 2 02 or Solaris 9   beta refresh  version of the Solaris operating environment  and Release 5 12 6 and  later of the system firmware     In addition  you have the option of installing the Sun Management Center  SunMC    Refer to the SunMC 3 0 Software Supplement for Sun Fire for complete instructions     Upgrading the System Firmware    An upgrade of the Sun Fire system firmware takes place via an ftp or http  connection from an ftp or http server where the firmware image is stored     Note     Additional information about installing the firmware patch is available in  the README and Install info files that accompany the patch                 v To Upgrade the System Firmware    1  Set up the ftp or http server     For more information  see Appendix B of the Sun Fire 6800 4810 4800 3800 Systems  Platform Administration Manual  part number 805 7373 13      2  Download the 5 12 7 firmware     This firmware and related documentation is included in SunSolve patch 112127 03   which is available on the SunSolve web site     http   sunsolve Sun COM pub cgi show pl target patches patch   access    3  Copy the patch onto the ftp or http server using a command such as the following       cp  patch_location    export ftp pub 5 12 7    4  Follow
21. ion  Bug ID  4453985     Workaround  None     12 Sun Fire 6800 4810 4800 3800 Systems Firmware 5 12 7 Release Notes   August 2002    System Controller Hangs After Automatic  setkeyswitch off  Bug ID 4454599     Manual reset of the system controller has no effect   Workaround  Do the following     1  Connect to each active domain through a network connection  telnet  rlogin   and so on     2  Shut down each domain if possible     3  Power off the Sun Fire system and power it on again     No LED Fault Indicator On System Board After  The Board Fails POST  Bug ID 4454623     Workaround  Use showlogs or showboards  from the platform shell  to show  errors and test status of a faulty system board     scapp Can Report Incorrect CPU For An ECC  Error  Bug ID 4477131     Workaround  ECC error messages do not report the correct CPU  Decode the agent  ID  AID  in the ECC error message to obtain the actual destination CPU     SC to Frame Connection is Lost When  FrameManager Status Changes  Bug ID 4488092     The system controller closes the connection between the system controller and the  FrameManager when the system controller receives updated status information from  the FrameManager     Workaround  Reboot the system controller     Firmware Release Notes 13    showb  d domain Shows Boards That Are Not  Assigned To Domain  Bug ID 4488255     Workaround  Use the showboards command to know which boards are assigned to  the domain  Refer to the Sun Fire 6800 4810 4800 3800 System Contro
22. ller Command  Reference Manual for correct usage of the showboards command     Need Way To Recover Domain Password After  restoreconfig  Bug ID 4491293     If you change a domain password after using the dumpconfig command to save  platform and domain configurations  note that running the restoreconfig  command resets the domain passwords to the passwords recorded in the  configuration file  However  if you cannot remember the new password that you  created for the domain  you cannot access that domain     Workaround  Do the following     1  Write down any system configuration information that you can obtain  You will  use this information when you perform Step 4     2  Shut down all domains     3  Run the setdefaults command at the platform shell  The setdefaults  command sets all system parameters  including the assignment of boards to their  corresponding domains  to their default values     4  Reprogram the system by using the setupplatform and setupdomain  commands to enter configuration information that you obtained from Step 1     flashupdate May Not Update scapp and rtos   Bug ID 4491986     Workaround  Verify that the system controller network settings are correct  Verify  that the http or ftp server is functioning correctly  Retry the flashupdate command  until it succeeds     14 Sun Fire 6800 4810 4800 3800 Systems Firmware 5 12 7 Release Notes   August 2002    Software Licensing Problems With Host ID And  MAC  Bug ID 4492051     The current scheme of assigning the
23. local Sun Customer Care Center  or your service provider if you need assistance in accessing the list of current  patches and system firmware upgrades        System Controller Command Changes    Note that the following commands have been updated  but the changes are not yet  documented in the Sun Fire 6800 4810 4800 3800 System Controller Command Reference  Manual included in the this release     Modified Commands    showresetstate Output from this command now shows more  registers     New Command Options Parameters    showsc  v Includes clock source information     Firmware Release Notes 11       Known Sun Fire 6800 4810 4800  3800  System Limitations    scapp Does Not Detect AC Failures  Bug ID  4413905     If the AC input to a power supply fails and comes back within 19 seconds  scapp  believes V1 and V2 have been running continuously with no interruption  The  power supply was designed to have enough hold up charge to keep the  microcontroller active for at least 19 seconds  so scapp does not register a drop in  power until after 19 seconds  If the AC outage lasts for more than 19 seconds  the  microcontroller dies completely and scapp logs messages complaining about broken  environmental sensors    Workaround  There are three known workarounds    m Atthe platform shell  type poweroff psX poweron psx    m Physically remove and reinsert the power supply     a Reboot the system controller     System Controller Overwhelmed With Error Data   Preventing Fault Status Determinat
24. ment board is available       To disable a board temporarily with DR  complete the DR procedures in the Sun  Fire 6800  4810  4800  and 3800 Systems Dynamic Reconfiguration User Guide     Using FTP URLs    When you use certain system controller commands  such as flashupdate   dumpconfig  or restoreconfig  where the URL uses the FTP protocol  specify  absolute paths by typing a double slash      after the hostname  Otherwise  the path  is interpreted relative to the home directory of the specified user     The following examples show the various ways to specify an FTP URL     m URL that uses an absolute path name        ftp    user  password hostname  tmp directory             The example above references the  tmp directory     Firmware Release Notes 7    8      URL that uses a relative path name     ftp    user  password hostname tmp directory    In the example above  the path name references  home user tmp directory        a URL with anonymous FTP  no user name or password      ftp    hostname tmp directory    The path name in this example references  home ftp tmp directory     Firmware Upgrade Procedure    Use the following procedure to upgrade the firmware  This procedure assumes that  the firmware update is available on a ftp or http server  Refer to the Sun Fire  6800 4810 4800 3800 Systems Platform Administration Manual for more information        Caution     Do not update the system controller firmware without updating the  firmware for all your CPU Memory boards and I
25. n the board   Refer to the CPU Memory board chapter of the Sun Fire 6800 4810 4800 3800 Systems    Service Manual     4 Sun Fire 6800 4810 4800 3800 Systems Firmware 5 12 7 Release Notes   August 2002    3  Remove and replace the board     Refer to the CPU Memory board chapter of the Sun Fire 6800 4810 4800 3800 Systems  Service Manual     4  Check the version of the firmware that is installed on the board     Compare the x y z number format  If x and y are the same  then the flash images are  compatible  The firmware version of new replacement board must be same as the  board you just removed  Type        schostname SC gt  showboards  p version             5  If the firmware version of the replacement board or assembly is different from the  board you removed  update the firmware on the board     a If you have a CPU Memory board of the same type installed  use the  flashupdate  c command  Type     schostname SC gt  flashupdate  c source_board destination_board    For a description of command syntax  refer to the flashupdate command in  the Sun Fire 6800 4810 4800 3800 System Controller Command Reference Manual  Go  to Step 6     a If you do not have a CPU Memory board of the same type installed  use the  flashupdate  f command  Type        schostname SC gt  flashupdate  f URL board             For a description of command syntax  refer to the flashupdate command in the  Sun Fire 6800 4810 4800 3800 System Controller Command Reference Manual   6  Use DR to connect and configu
26. nc     The OPEN LOOK and Sun    Graphical User Interface was developed by Sun Microsystems  Inc  for its users and licensees  Sun acknowledges  the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry  Sun  holds a non exclusive license from Xerox to the Xerox Graphical User Interface  which license also covers Sun   s licensees who implement OPEN  LOOK GUIs and otherwise comply with Sun   s written license agreements     Federal Acquisitions  Commercial Software   Government Users Subject to Standard License Terms and Conditions     DOCUMENTATION IS PROVIDED    AS IS    AND ALL EXPRESS OR IMPLIED CONDITIONS  REPRESENTATIONS AND WARRANTIES   INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY  FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT   ARE DISCLAIMED  EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID        Copyright 2001 Sun Microsystems  Inc   4150 Network Circle  Santa Clara  CA 95054 Etats Unis  Tous droits r  serv  s     Ce produit ou document est distribu   avec des licences qui en restreignent l   utilisation  la copie  la distribution  et la d  compilation  Aucune  partie de ce produit ou document ne peut   tre reproduite sous aucune forme  par quelque moyen que ce soit  sans l autorisation pr  alable et    crite de Sun et de ses bailleurs de licence  s   il y en a  Le logiciel d  tenu par des tiers  et qui comprend la technologie relative aux polices de
27. oards and  Assemblies    The replacement board must have the same version of firmware as the system  controller and other CPU Memory boards or I O assemblies  After installing a  board or assembly  use the showboards  p version command to show the  firmware version of each board  If the firmware for the board or assembly you  replaced is different from the system controller firmware  you will have to update  the board or assembly firmware     If an update is required  be sure that the board is powered on and use either the  system controller flashupdate  f or flashupdate  c command  Refer to the  Sun Fire 6800 4810 4800 3800 System Controller Command Reference Manual for correct  usage of the flashupdate command     If the output from the showboards command indicates that a board or assembly is  in a failed state  you must power off the board or assembly to clear the failed state     10 Sun Fire 6800 4810 4800 3800 Systems Firmware 5 12 7 Release Notes   August 2002    Note     Do not use the flashupdate  u command even if onscreen messages  indicate to do so  Using flashupdate  u could result in incompatibility issues that  require a reboot of the system controller and domains     A list of the most current patches for bug fixes and system firmware upgrade may be  found on SunSolve Online  SunSolve provides recommended and security patches   including Year 2000 patches  to all users  Other product and OS patches are available  to SunSpectrum Contract customers  Contact your 
28. ompactPCI    You can unconfigure a CompactPCI  cPCI  I O assembly only if all the cards in  the board are in an unconfigured state  If any cPCI card is busy  such as with a  plumbed up interface or a mounted disk   the board unconfigure operation fails  with the status    busy     All cPCI cards should be unconfigured before attempting  to unconfigure the cPCI I O assembly     When a multipath disk is connected to two cPCI cards  it is possible to see disk  activity across the cards when none is expected  For this reason  make sure that  there is no activity on the local side of the resource  This is more likely to occur  when attempting to perform DR operations on a cPCI card that shows a busy  status  even when there is no activity on the local side of the resource  A  subsequent DR attempt may be required     Firmware Release Notes 21    a When a user lists the attachment point by using the cfgadm 1M  command with  the  a option  cPCI slots and PCI buses are listed as attachment points  The  cfgadm  a command displays an attachment point for a PCI bus as  NO IB8  pci0  There are four such attachment points for each cPCI board  The  user should not perform DR operations on these  nor on the sghsc attachment  point  which the cfgadm  a command displays as NO IB8  sghsc4   because  DR is not actually performed  and some internal resources are removed  However   there is no harm in doing so     m In order for DR to function properly with cPCI cards  the levers on all cPCI card
29. on to  user processes running in the domain    You can use DR to do the following     m Shorten the interruption of system applications while installing or removing a  board    m Disable a failing device by removing it from the logical configuration  before the  failure can crash the operating system    a Display the operational status of boards in a system    m Initiate system tests of a board while the system continues to run    2 Sun Fire 6800 4810 4800 3800 Systems Firmware 5 12 7 Release Notes   August 2002    m Reconfigure a system while the system continues to run    m Invoke hardware specific functions of a board or a related attachment    The DR software uses the cfgadm command  which is a command line interface for  configuration administration  You can perform domain management DR tasks using  the system controller software  The DR agent also provides a remote interface to the  Sun Management Center software on Sun Fire 6800 4810 4800 3800 systems     For complete information on DR  refer to the Sun Fire 6800  4810  4800  and 3800  Systems Dynamic Reconfiguration User Guide included with this release and also the  Solaris documentation included with the Solaris operating environment     Before Creating Multiple Domains    Chapter 4  Creating and Starting Multiple Domains  in the Sun Fire  6800 48 10 4800 3800 Systems Platform Administration Manual explains how to create  and start multiple domains     The text for Step 6 in the procedure    Before Creating Multiple
30. perations occur  or when psradm is run at the same  time as a DR operation  the system can hang because of a mutex deadly embrace     Sun Fire 6800 4810 4800 3800 Systems Firmware 5 12 7 Release Notes   August 2002    Workaround  Perform DR operations serially  one DR operation at a time   and  allow each to complete successfully before running psradm  or before beginning  another DR operation     Unable to Disconnect SCSI Controllers Using DR    Bug ID 4446253     Description  When a SCSI controller is configured but not busy  it cannot be  disconnected using the DR cfgadm  av command     Workaround  None     cryptorand Stops After Removing a CPU Board  Using Dynamic Reconfiguration  Bug ID 4456095     If a system is running the cryptorand process  which is found in the SUNWski  package  an unconfigure of memory  such as part of a CPU Memory  SB  board  disconnect  causes cryptorand to close with messages recorded in   var adm messages  This denies random number services to secure sub systems   and any memory present when cryptorand is started should not be unconfigured     The cryptorand process supplies a random number for  dev random  After  cryptorand is started  the amount of time before  dev  random becomes available  depends on the amount of memory in the system  It takes about 2 minutes per Gbyte  of memory  Applications that use  dev random to get random numbers may  experience temporary blockage  It is not necessary to restart cryptorandifa  CPU Memory board is add
31. re the board back into the domain   Refer to the Sun Fire 6800  4810  4800  and 3800 Systems Dynamic Reconfiguration User  Guide   7  Verify the state of the LEDs on the board     Refer to the CPU Memory board chapter of the Sun Fire 6800 4810 4800 3800 Systems  Service Manual     Firmware Release Notes 5    v To Hot Swap an I O Assembly    The following procedure describes the software steps needed to hot swap an I O  assembly and test it in a spare domain not running the Solaris operating  environment    1  Use DR to unconfigure and disconnect the I O assembly out of the domain   Refer to the Sun Fire 6800  4810  4800  and 3800 Systems Dynamic Reconfiguration User  Guide   2  Verify the state of the LEDs on the assembly   Refer to the I O assembly chapter of the Sun Fire 6800 4810 4800 3800 Systems Service  Manual    3  Remove and replace the assembly   Refer to the I O assembly chapter of the Sun Fire 6800 4810 4800 3800 Systems Service  Manual    4  Check the version of the firmware that is installed on the assembly     Compare the x y z number format  If x and y are the same  then the flash images are  compatible  The firmware version of new replacement assembly must be same as the  assembly you just removed     schostname SC gt  showboards  p version    5  If the firmware version of the replacement assembly is a different from the  assembly you removed  update the firmware on the assembly        For a description of command syntax  refer to the flashupdate command in th
32. s  that are inserted at Solaris boot time must be fully engaged     Procedures for Bringing a cPCI Network Interface  IPMP   Online or Offline    v To Take a cPCI Network Interface  IPMP  Offline and  Remove It     1  Retrieve the group name  test address  and interface index by typing the following  command          ifconfig interface             For example  ifconfig hme0    2  Use the if mpadm 1M  command as follows          if_mpadm  d interface             This takes the interface offline  and causes its failover addresses to be failed over to  another active interface in the group  If the interface is already in a failed state  then  this step simply marks and ensures that it is offline     3  Unplumb the interface  This step is required only if you want to use DR to  reconfigure the interface automatically at a later time     4  Remove the physical interface     Refer to the cfgadm  1M  man page and the Sun Enterprise 6800  4810  4800 and 3800  Systems Dynamic Reconfiguration User Guide for more information     22 Sun Fire 6800 4810 4800 3800 Systems Firmware 5 12 7 Release Notes   August 2002    Y To Attach and Bring Online a cPCI Network Interface   IPMP      1  Attach the physical interface     Refer to the cfgadm 1M  man page and the Sun Enterprise 6800  4810  4800 and 3800  Systems Dynamic Reconfiguration User Guide for more information     2  After you attach the physical interface  it is automatically configured using  settings in the hostname configuration file
    