1. DEN 1111 DEN 1 Level 1 To count dark colored thick notes DEN 11 Level 2 To count high density notes DEN 111 Level 3 To count median density notes DEN 1111 Level 4 To count light colored thin notes When counting very dark colord notes or very thick notes this OFF Blank function should be turned off But machine can not detect Double Feeding Batch Mode 1 Total Sheets tw l i Lt Message DEN 1 Speed 1 E UV Detection Function option gt UVD function is to detect the fluorescence on notes A counterfeit note that generates fluorescence under the ultraviolet rays can be detected when this function is set ON The machine will stop showing message CF1 The suspected note is the last one in the stacker Take the suspected one away and press RESTART key to countinue the counting The suspected one isn t included in the counted result Four sensitivity levels can be selected by pressing UVD key UVD 1 UVD 11 UVD 111 UVD 1111 UVD 1 Level 1 To count notes of the lowest UV sensitivity level UVD 11 Level 2 To count notes of middle UV sensitivity level UVD 111 Level 3 To count notes of high UV sensitivity level UVD 1111 Level 4 To count notes of the highest UV sensitivity level OFF Blank Function inactive E MG Detection Function option amp This function is to detect the magnetism on notes Through this function the mach
2. Three Digits LCD Power Source AC110 220V 50 60Hz Power Consumption lt 55W Dimensions 272mmx235mmx239mm Weight 5 5Kg Counting Speed Speed 1 900 notes min Speed 11 1200 notes min Speed 111 1600 notes min ADJUSTMENT OF THE FEED GAP The correct Feed Gap is vitally important to the smooth functioning of the machine After a long term usage the rubber components of both the Feed Roller and the Friction Roller may be subject to natural wear Under this condition the Feed Gap may become too wide and as a result Error Codes will be generated and note feeding will become erratic To check and adjust the Feed Gap to counteract this simple wear condition follow the 3 steps below in conjunction with the photograph 1 Manually insert a genuine banknote into the Feed Gap and move it back and forth If you don t feel any resistance it indicates the gap is too wide if the resistance is very strong it indicates the gap is too narrow 2 Ifthe Feed Gap is found to be too wide adjust the Thickness Knob counter clockwise to reduce the Feed Gap until the proper slipping resistance is achieved with your banknote 3 If the Feed Gap is found to be too narrow adjust the Thickness Knob clockwise to increase the Feed Gap until the proper slipping resistance is achieved with your banknote 12 7 DAILY CARE Clean the following Sensors with a brush periodically Hopp
3. Banknote Counter INSTRUCTION MANUAL 2009 Edition V1 2 CONTENT 1 OVERALL DESCRIPTIONS 1 1 Names and Functions of Parts 1 2 Names and Functions of Keys 2 FUNCTIONS 3 BASIC OPERATION 4 DEFAULT SETTINGS IN FACTORY 5 SPECIFICATIONS 6 ADJUSTMENT OF THE FEED GAP 7 DAILY CARE 8 ERRORS AND REMEDIAL MEASURES 9 ACCESSORIES amp OPTIONS 11 11 12 12 13 14 15 1 OVERALL DESCRIPTIONS 1 1 Names and Functions of Parts E Front View aAuxiliary Hopper Plates Stacker Hopper The counted notes are placed in it Auxiliary Hopper Plates Used for leading the notes to the feeding mechanism Keys Refer to page 5 for description of each key Display The Display shows all the messages Stacker Counted notes are stacked onto the Stacker Rear View Thickness Adjustment Knob O Carrying Handle Power Switch ORS232 Interface Power Inlet Thickness Adjustment Knob Used to adjust the Feed Gap to make the counting smooth To widen the Feed Gap by turning the Knob towards sign and to narrow the Feed Gap towards sign Carrying Handle Used for carrying the machine Power Switch Used to turn on or off the machine Power Inlet Used to connect the Power Cable RS232 Interface Used to connect the machine to a computer T w Names and Functions of Keys By this key each counted result will be added to the previous one Aut
4. C OPERATION Step 1 Turn on the Power Switch ON OFF Step 2 Set batch number by pressing 0 9 keys if necessary Step 3 Set Counting Speed Auto or Manual Start function DEN UVD MGD functions if necessary Step 4 Load the notes onto the Hopper and set the right position to the Auxiliary Plates Then press RESTART key to start counting if necessary 4 DEFAULT SETTINGS IN FACTORY m Turn the Power Switch on the machine will be in the previous setting E Turn on the Power Switch while pressing the RESTART key for 2 seconds and the machine will be in the default settings The default settings in factory are as follow Function Settings Descriptions DEN DEN 1 Level 1 To count dark colored thick notes UVD UVD 11 Level 2 To count notes of middle UV sensitivity MGD MGD 11 Level 2 To count notes of middle magnetic sensitivity ADD OFF ADD function is off SPEED Speed 11 1200 notes min MNL OFF Auto Start is on Batch 100 100 sheets 11 SPECIFICATIONS Ambient Temperature 0 40 C Ambient Humidity 20 80 Feeding System Roller Friction System Hopper Capacity 400 notes Stacker Capacity 200 notes Size of Countable Note 50x90 110x185 mm Thickness of Countable Note 0 05 0 2 mm Batch Number Displayed Three Digits LCD Counting Number Displayed Seven Digits LCD Message Displayed
5. LLER NCC Driver in the computer 3 Run the NCC EXE and the computer will be connected to the banknote counter 15
6. ensors is 3 Replace the damaged Counting Sensor damaged Ec More than two notes are fed in If this error happens very often the Feed Gap might be too wide chain Adjust the size of the gap Refer to Chapter 6 Ed Two notes are fed at a time or a If this error happens very often adjust the DEN Function Refer dirty note is fed to Chapter 6 of the Service Manual 1 Take away the last note from the Stacker and make sure that it CFI Suspected counterfeit note is is the same note as the others detected by UV detection 2 Press RESTART key 3 Recount the last note taken away from the Stacker 1 Take away the last note from the Stacker and make sure that it cr Suspected counterfeit note is is the same note as the others detected by MG detection 2 Press RESTART key 3 Recount the last note taken away from the Stacker 14 9 ACCESSORIES amp OPTIONS 9 1 Accessories 1 Power Cable 1 2 Instruction Manual 1 3 Brasher esante oot 1 9 2 Options 1 External Display An option of the External Display is available which will show the counting results synchronizingly when connected to the RS232 interface of the banknote counter 2 NCC Driver and RS232 Serial Cable for connecting the banknote counter to a computer 1 Connect one end of the serial cable to the serial port of your computer and the other end to the RS232 port of the banknote counter 2 Install the NOTE COUNTER CONTRO
7. er Sensor and Stacker Sensor Hopper Sensor Stacker Sensor Counting Sensors Counting Sensors 13 When an error occurs during counting the LCD Display will flash the error code Clear the error in accordance with the following procedures pe Cause of Error Remedial Measures Code EA Hopper Sensor is covered Remove what is covering the Hopper Sensor 1 One or both of Counting Sensors 1 Replace the damaged Counting Sensor are damaged if El appears when 2 Clean the Counting Sensors Refer to Chapter 7 El power on 3 Take away jammed note s with hand When there is a 2 Counting Sensors are dirty difficulty in taking away the jammed notes turn Drum 3 Notes are jammed in the roller Rollers by hand 1 Notes on Stacker when power Gri 1 Remove the notes placed on the Stacker E2 Parr 2 Clean the Stacker Sensor with the brush Refer to Chapter 7 2 Stacker Sensor is dirty 3 Replace the damaged Stacker Sensor 3 Stacker Sensor is damaged 1 Hopper Sensor is covered when power on 1 Remove what is covering the Hopper Sensor E3 Sse 2 Clean the Hopper Sensor with the brush Refer to Chapter 7 2 Hopper Sensor is dirty 3 Replace the damaged Hopper Sensor 3 Hopper Sensor is damaged 1 Half sized note is fed 2 A small note passes from the left 1 Take away the half sized note EH or right side 2 Let the note pass in the middle 3 One of Counting S
8. ine can detect counterfeit notes without magnetism When a counterfeit note is detected the machine will stop and show the error message CF2 The suspected note is the last one in the stacker Take the suspected one away and press RESTART key to countinue the counting The suspected one isn t included in the counted result Four sensitivity levels can be selected by pressing MGD key MGD 1 MGD 11 MGD 111 MGD 1111 Blank MGD 1 Level 1 To count notes of the lowest magnetic sensitivity level MGD 11 Level 2 To count notes of middle magnetic sensitivity level MGD 111 Level 3 To count notes of high magnetic sensitivity level MGD 1111 Level 4 To count notes of the highest magnetic sensitivity level OFF Blank Be ae should be turned off when counting notes without Batch Mode 1 Total Sheets rm vi i wt DEN 1 Speed 1 E Value Calculation Function E gt gt This function is to select the denomination of notes to be counted and check total value after counting notes of the selected denomination key DNMNT 1 gt 2 gt 5 gt 10 20 50 100 blank off Step 1 Switch to the denomination of notes you are going to count by pressing key Step 2 Count notes of the selected denomination Step 3 Press VALUE key to check the total value when counting stops Batch Mode 1 Total Sheets a ni vs u ut DNMNT DEN 1 Speed 1 10 3 BASI
9. key When MNL is shown on the display the Manual Start function is activated When MNL is not shown on the display the Auto Start function is selected Batch Mode 1 Total Sheets rm vs ut Lt Message Speed 1 NL E Counting Speed Function An appropriate speed can be chosen by pressing this key changeable in three levels Slow Normal Fast Speed 1 900 notes min Slow Speed 11 Default 1200 notes min Normal Speed 111 1600 notes min Fast Batch Mode 1 Total Sheets rm i Li wt E BATCH Function Machine will count notes by batch if batch function is activated After counting every batch of notes the machine will stop Then continue the counting by taking away the notes from the Stacker or by pressing RESTART key o oo Batch Mode 1 Total Sheets a h F L Message DEN 1 Speed 1 The BATCH key is used to set 4 pre programmed batch numbers The batch number will switch among 10 25 50 100 everytime BATCH key is pressed To clear the batching press BATCH key for 3 seconds BATCH key 1025 50 100 The 0 9 keys are used to set any batch number from 0 to 999 E Double Feeding Detection Function ED Machine detects Double Feeding by DEN function The detection level can be selected by DEN key depending on the density of the notes Four different levels can be chosen by pressing DEN key in the following sequence DEN 1 DEN 11 gt DEN 111
10. o start and Manual start can be selected by this key This key can clear counted result batch number or exit denomination setting in that order An appropriate speed can be chosen by this key changeable in three levels Slow Normal Fast Used to switch the batch number between 10 25 50 and 100 By this key the reference level for two sheets detection can be changed according to the density of the notes to be counted By this key the machine is set to detect counterfeit notes by the detection of fluorescence option By this key the machine is set to detect counterfeit notes without magnetism option Used to select the denomination of notes to be counted Used to check the total value after counting notes of the selected denomination Used to initiate a counting operation or clear an error message D To set the batch number with 0 9 keys wm 2 FUNCTIONS E ADD Function ED Press ADD key to turn on or off this function ADD will be shown on display when it s on Batch Mode 1 Total Sheets m nm vs Lt Lt ADD hes sage Speed 1 Every time the machine has completed counting the Display will show accumulated count Press C key to clear the accumulated count E Auto and Manual Start Functions E gt Auto Start and Manual Start can be chosen by pressing MNL key Auto Start Counting starts automatically after loading notes onto the Hopper Manual Start Start counting by pressing RESTART