Ultegra™ Bench Scale SCB-R9000-14U USB
Contents
1. faulty USB port or AC adapter IF you are using a remote display check the main display first if it s OK then check the cable plug connection on the remote Unplug then plug in the power cord to reset the program Incorrect Weight Check platform for binding or rubbing reposition scale so all sides are clear Ensure correct UNITS are displayed lb or kg For scales in counter inserts make sure there is nothing jammed around edges Remove load press the ZERO key to set the scale to 0 00 then reweigh ZERO key will NOT reset zero Motion on the platform ensure that the platform is empty Check platform for binding or rubbing reposition scale so all sides are clear For scales in counter inserts make sure there is nothing jammed around edges Unplug then plug in the power cord to reset the program 09 13 10 51222 Rev 3 FN Section 4 Customer Care Problem Possible Source Remedy First unplug then plug in the power cord to reset the program IF you are Pushbuttons Will Not Operate using a remote display check the main display first if it s OK then check the cable and plug connection on the remote First unplug then plug in the power cord to reset the program IF you are Display Locked or Inoperative using a remote display check the main display first if it s OK then check the cable and plug connection on the remote Display Indicates HiCAP Weight on the platform exceeds 150 Ibs
2. includes scale status units and weight 09 13 14 51222 Rev 3 MIA AAW FAIRBANKS Way SONA Manufactured by Fairbanks Scales Inc ULTEG RA BENCH SCALE OPERATOR MANUAL 821 Locust DOCUMENT 51222 Kansas City Missouri 64106 www fairbanks com
3. remove load Check that both cable end connectors are securely fastened Check ES the cable for damage Check the Hub or USB port for problems 09 13 11 51222 Rev 3 SECTION 5 SPECIFICATIONS 9 1 TECHNICAL SPECIFICATIONS 09 13 _ Capacities 150 Ib 68 kg factory set Rounding Nearest division per NIST H 44 Weight Display 27 inch LCD Display Power On Lockout Scale will display when power is turned on and weight is present Press ZERO to establish zero reference Display update rate 0 05 seconds Overcapacity Warning e Displays HiCAP for overcapacity Motion Detection Satisfies H 44 requirements Power Failure Protection Zero reference programming and calibrations are retained if the instrument loses power Load Cell Excitation 3 3VDC 10 USB Cable Length Type A B 6 feet in length 11 Indicators Ib kg 12 Dimensions Platform Including Feet 14 x 14 x 2 5 13 Auto Zero Tracking Compensates for gradual buildup of material on platform factory set at 0 5 divisions 14 Power Requirements 5VDC USB or AC adapter 15 Approvals NTEP CC 98 198 MC AM 5298 RoHS Compliant 12 51222 Rev 3 AA AS i HH H 77 sd EE Section 5 Specifications 9 2 ENVIRONMENT All equipment should be protected from direct sunlight e Relative Humidity 0 to 90 non condensing e NOT suitable for water wash down 1 Remote Display 29595C
4. ACC 1520 1 6 98 W x 3 48 H 1 29 D RJ45 cable and two 2 function buttons Remote Display 29595 2 AC Adapter 30015 Input voltage range of 90 to 264 VAC 47 to 63 Hz Output 5VDC via 2 1mm barrel plug AC Adapter 30015 3 Counter Insert Kit 21100 Allows the unit to be placed at slightly above a counter top for easier weighing A remote display 29595 will be needed for display purposes 4 Remote Display Stand 20301 A 18 high stand for mounting the Remote Display ideal for counter top applications 09 13 13 51222 Rev 3 APPENDIX I USB OPERATION A OVERVIEW The Ultegra Bench Scale is a low power full speed device A low power USB device draws less than 100mA A full speed device operates at 12Mbits s It uses default Windows drivers and is installed automatically upon first connection with a PC The maximum USB cable length is 5 meters unless a self powered hub is used to extend the cable length When a PC goes into standby mode the scale is forced into a low power mode to comply with USB specifications At this time the scale displays SLEEP which remains until the PC resumes normal operation The device is displayed at the following location in Windows Control Panel gt System gt Hardware gt Device Manager There are two items displayed for the unit HID compliant device and USB Human Interface Device The scale sends data to the PC using a Point of Sale POS format A typical USB report
5. Approved Measurement Canada Approved RoHS Compliant lead free 09 13 4 51222 Rev 3 SECTION 2 SETUP 2 1 INSTALLING 1 Remove the scale from the packing box and place on a flat surface where it will be used 2 Using the level bubble adjust one or two feet minimally to level the platform Do NOT adjust all four 4 feet 3 For counter installation install kit 21100 using the drawing The suggested cut out size is 15 Va x 15 Va 2 2 CONNECTIONS 1 USB To use the USB interface plug the included six foot 6 USB cable into the scale base where marked output 1 Connect the other end into a USB port on your computer or USB hub See figure below 2 REMOTE DISPLAY To use a remote display plug the remote display into the connector on the scale base where marked remote display Mount the remote using 2 screws or use a velcro strip not included A stand PN 20301 can also be used 3 AC ADAPTER To use an AC adapter plug the barrel plug into the back of the scale where marked optional power and the AC adapter unit into a proper outlet Check the AC receptacle for proper voltages prior to plugging in the adapter 4 Check with your freight provider for compatible computer software 09 13 5 51222 Rev 3 AA Section 2 Setup 2 3 COMPUTER CONNECTIONS 1 USB setup The USB port will only function with a computer utilizing Windows 2000 Windows XP or higher operating system Wh
6. MIA FAIRBANKS Onerator Manual Ultegra Bench Scale SCB R9000 14U USB Powered All rights reserved Revision 3 09 13 Amendment Record Ultegra Bench Scale SCB R9000 14U USB Powered 51222 Manufactured by Fairbanks Scales Inc 821 Locust Kansas City Missouri 64106 Created 09 2009 Revision 1 09 2009 New Product Release Revision 2 07 2013 Corrected part numbers added logos for NTEP MC and RoHS Revision 3 09 2013 New feature added of adjustable gravity compensation and updated manual format Disclaimer Every effort has been made to provide complete and accurate information in this manual However although this manual may include a specifically identified warranty notice for the product Fairbanks Scales makes no representations or warranties with respect to the contents of this manual and reserves the right to make changes to this manual without notice when and as improvements are made Copyright 2009 2013 This document contains proprietary information protected by copyright All rights are reserved No part of this manual may be reproduced copied translated or transmitted in any form or by any means without prior written permission of the manufacturer 09 13 2 51222 Rev 3 TABLE OF CONTENTS 09 13 Section 1 General Information 1 1 Introduction ee ee ee ee ee ee ee ee ee ee ee ee ee 4 1 2 ee ei EE AE EE EE EN rtnn nnrnneenneennn ennnen 4 Section 2 Setup 2 1 ie N EE EN iea 5 2 2 CONNEEU
7. ONS es ERG EE GN eN ke Go DE EE ee ie 5 2 3 Computer Connections ES Se BEERS ses ie ed Dog DER Ke 6 2 4 Gravity Use Compensation SettiNg esse 6 Section 3 Using the Scale 3 1 Wc cece ceeds She ER ER Ge ee 8 32 aa ee HEEL N ON EE 8 3 3 VV TONING ss RE EE N DERE RE DER EERS ERGER Ese ad ee ere 9 Section 4 Customer Care ede EE EE ene EE EE EO ye 10 4 2 Operator Instrument PromptS iese sesse ees ee ee RR EG 10 4 3 TreublesHOOEE ss se ee eo ee Ee ee ae 10 Section 5 Specifications 5 1 Technical Specifications eie Ee 12 5 2 EIN IPO VIN se es ee N Se 13 5 3 PAC SS SONIC Si NG es ER a 13 Appendix I USB Operation ii ee ee AR RA RR RE ER ee 14 3 51222 Rev 3 SECTION 1 GENERAL INFORMATION 1 1 INTRODUCTION The Ultegra Bench Scale is a USB powered unit with a capacity of 150 lbs and is constructed of ABS composite material The scale may be placed on a desk bench or used with an Insert adapter to countersink into a counter top Units may be ordered with a ball roller deck surface 1 2 DESCRIPTION This unit can be powered from any PC that is compliant with version USB 1 1 or later This includes external hubs either bus powered or self powered The scale is identified by a PC as a human interface device HID and operates with Windows 2000 Windows XP or later It also can be powered from a 5VDC AC adapter A USB port is not required when powered from an AC adapter NTEP
8. anga Colombia Press the ZERO key to accept the choice selected and the display will indicate AZt 0 5 Press the Program button to return to the weighing mode This completes setting the Gravity Use Zone setting 09 13 7 51222 Rev 3 SECTION 3 USING THE SCALE 3 1 POWER ON Because the scale uses special low power circuitry no warm up time is required Weight readings will be accurate as soon as the unit is powered on and set to zero When the unit is powered the liquid crystal display LCD will show the software part number and the revision followed by either 0 00 or Dashes are displayed to indicate the scale is registering a weight upon startup Press the ZERO key to set the display to 0 00 and start weighing 3 2 KEYS The keys for operating the scale are located on the main display and on the remote display NOMINAL CAPACITY 0 150 X 05 Ib 0 68 X 02 kg EuCENTER OF ZERO lb kg Fairbanks Scales 50212 10 1 Pressing the ZERO key resets the display to indicate zero 0 a The zero range is set at 2 or 3 00 Ibs when set for Canadian use b The zero range is set at 100 or 150 Ibs when set for USA use 2 The ZERO key function will be inhibited if the instrument detects any of the following conditions a Motion on the platform b An underload condition c An overload condition d Outside of programmed zero range 3 Pressing the UNITS key tog
9. en the scale connected USB cable is interfaced to a computer s USB port or USB hub the computer will prompt a device has been found and it will automatically install the driver 2 4 GRAVITY USE COMPENSATION SETTING The SCB R9000 14U has a gravity use compensation setting which must be set based upon the geographical zone in which the scale is being installed Access this setting by pressing the Program button The button is located looking at the front of the scale inside the right rear portion of the scale An access cover must be removed 1 The display will show GrU x This is the Gravity Use Zone Select the proper zone number for your location Use the UNITS key to toggle to the selection The choices are 8 7 6 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 Zone Latitude degrees Reference City 8 68 659 Point Hope AK 7 64 929 Fairbanks AK 6 61 567 Anchorage AK 5 58 444 Fort Vermilion Alberta 4 55 485 High Prairie Alberta 3 52 638 Coventry England 2 49 865 Winnipeg Manitoba 1 47 137 Tacoma WA 0 44 427 St Johnsbury VT 1 41 711 Des Moines IA 2 38 963 Kansas City MO 09 13 6 51222 Rev 3 AA Section 2 Setup Zone Latitude degrees Reference City 3 36 156 Tulsa OK 4 33 257 Tuscaloosa AL 5 30 223 Austin TX 6 26 992 Navojoa Mexico 7 23 467 Mazatlan Mexico 8 19 476 Mexico City 9 14 622 Guatemala City 10 7 326 Bucaram
10. gles the weighing units and the display indicators between Ib to kg Verify the units you want to use by noting the arrow indicator on the display 09 13 8 51222 Rev 3 dane Section 3 Using the Scale 1 With the platform empty press the ZERO key The display will indicate zero Note The C to the left of the 0 00 indicates true center of zero 2 Check that the correct units are indicated press the UNITS key to change to Ib or kg 3 Place the item to be weighed centered on the platform 4 Read the Gross weight from the display 50212 11 09 13 9 51222 Rev 3 SECTION 4 CUSTOMER CARE 4 1 CLEANING Clean by wiping the scale assembly off with a damp cloth only Do not use running water harsh chemicals or allow liquids to drip onto the scale display 4 2 OPERATOR INSTRUMENT PROMPTS Prompt Description HiCAP Load 150 Ibs 68 kg or greater over capacity LoCAP Scale is below normal Zero range under capacity Shown at startup Indicates the scale is not within the center of zero range Press the ZERO key to go to weigh mode Shown at startup Motion is preventing the scale from entering the weigh mode 43 TROUBLESHOOTING In the event the scale does not function properly check the following Problem No Display Possible Source Remedy Power OFF plug disconnected cord damage
Download Pdf Manuals
Related Search
Related Contents
WU2S-Install-UserManual-1 T7xI-01 TreadmIll SerVICe maNUal FX Configurator-FP オペレーションマニュアル Touch 'n Foam 4006002506 Installation Guide Samsung WB200F Kasutusjuhend 全自動血圧計 取扱説明書 Setting & Monitoring Tool Manual - Automation Systems and Controls An Assessment of Current Qualitative Simulation Techniques Integral IN3T1GEYNGXK3 memory module PCE-2800 Leeb Hardness Tester User`s Manual Copyright © All rights reserved.