Home
ZM-L35T Manual - Go Electronic
Contents
1. on the environment and amount of operation Please follow the correct charging method in order to extend the life of the battery CBC AMERICA Corp CAUTION 1 Although the test monitor can work and charge at the same time you must not measure the AC voltage while battery is in charging mode 2 When users see the flash of the F on the screen this indicates that the fuse needs to be changed For details on how to change the fuse please check the user manual When users see the flash of the F on the screen the rest of the device functions should still work normally 3 When the battery is totally discharged please switch power to OFF while charging do not attempt to operate and charge simultaneously when the battery has been totally discharged Product Dimensions AN 7 AT 7 ae f ay jE amp HIN TANTEI L Bi i 000 ij GOC CBC AMERICA Corp Specifications 4 2V 10 0 2V pp Voltage peak to peak value NTSC PAL auto detection Built in Speaker for Testing 8 Q 1W 0 to 45 Celsius 32 to 113 F V1 5 85 TM0350 A002G D
2. CBC AMERICA Corp Thank you for purchasing this product Please read the User s Manual before using the product User s Manual is subject to change without notice 3 5 LCD CCTV Test Monitor Accessories Carrying Case Monitor Guard Terminal Blocks Battery Pack AC Adapter Meter Probes Video Cable Necklace Belt Hand Link 1 2 3 4 5 6 7 8 9 0 CBC AMERICA Corp SAFETY PRECAUTIONS Please read before using equilateral triangle is intended to alert the user to the presence of insulated dangerous voltage within the product s enclosure that may be sufficient magnitude to constitute risk of electrical shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operation and maintenance servicing instructions in the literature accompanying the appliance p The lightning flash with arrowhead symbol within an 1 Ground loop may cause electrode to short circuit User should follow the instructions below in order to avoid accidental shock a Don t connect other inputs or outputs to device while in AC DC mode b Don t measure AC DC voltage while in any other type of function Cc Don t operate AC DC function while in charging mode 2 Please read all details contained in the service manual before using this device 3 Do not attempt to disassemble the chassis as this could lead to electric shock or damage to th
3. e internal components of the device 4 Do not attempt to service this unit yourself unless you are authorized to do so Opening cover could lead to exposure to dangerous voltage or other hazards Refer all servicing of this device to qualified personnel only 5 Please connect all external components firmly before using to prevent damage 6 Please connect in accordance with the instructions to prevent the device from accidental damage 7 Please don t use any organic solution or corrosive chemical to clean the chassis While cleaning please turn off the power to the device Use a clean lint free cloth with a small amount of water to clean all surfaces 8 Please don t use this device under the following environmental conditions Temperature lower than 10 C 14 F or higher than 50 C 122 F CBC AMERICA Corp Exploring Your Test Monitor Directional Buttons MENU key 4 MODE key ISP interface D Power Switch RS 232 Port Video Extension Cord 43 Positive Probe 44 Negative Probe Cable1 G Rx Tk Cab Ge Ame ae E S as a aan pee meee 23 5 0 9 at came a B gim Y a pre i Upgrade Firmware Interface Turn On Off Test Monitor 9V Adapter Cable Open Short Circuit Test x 2 sets PTZ Protocol Test for RS485 Port Terminal Debug for engineer only Connect to Video In Out and Audio In Cable Probe for DC AC Voltage Measurement P
4. e speed of the navigation With the A and VW buttons you can change the preset number gradually With the lt and gt buttons you can change the preset number in tenner steps CBC AMERICA Corp 4 Cable Test Open or Short Circuit test for 2 sets of wires a Switch MODE key to get CABLE TEST page b Connect two ends of termination with Cable Test Terminal to test whether circuit status is OK Short or NG Open as shown below c The 2 test channels are independent to allow testing of both parts of a 2 conductor cable simultaneously 5 Audio Test a Switch MODE key to get VIDEO page b Click Up key or Down key to open or close speaker for testing the audio output Default is ON as shown in the diagram below AUDIO ON 1 63 CBC AMERICA Corp Type C Video Pattern Generator 6 Standard Pattern Output for monitor testing a Switch MODE key to get PATTERN OUT page b Connect the Video In of monitor with Video Out of video extension cord to display 8 color bar standard pattern as shown below c Switch between NTSC PAL video formats using the Down key CBC AMERICA Corp OSD Menu Illustration 1 Language Press the Menu key gt Down key gt Language Choose from English Fran ais Deutsch Italiano Espa ol and Chinese languages Sleep Time is a sleep mode timer setting when the test
5. monitor is not being used the system will turn off power automatically after a period of time 3 Battery status Displayed on the upper right corner of the screen showing battery capacity When the level is full the battery will provide 6 hours of usage while the lowest level should provide about 5 minutes to check important data and prepare to power off 4 Charging method System indicator will show charging status Charging the battery while powered off is better for the battery life and allows for faster battery charging time 5 Calibration method Adjust the Brightness value to 30 then press and hold the Mode key and then the Right key to enter calibration mode The default value is 128 and the user may adjust between values from 0 250 to decrease or increase the ratio from 0 2 times the measured value The adjustable measurement parameters include Video level AC and DC voltage and the calibration values will be saved and retained until the next time a value is re calibrated NOTE Before using the test monitor for the first time please charge the battery for at least 5 hours to make sure that the battery is fully charged This will extend the usage life of the battery After the initial charge the battery should only require charging for about 2 3 hours in order to be charged fully This should provide enough power to use the device for about 5 6 hours Battery life should allow recharging about 250 times depending
6. programme the speed dome you need to switch to the PTZ Mode of the monitor Enter the speed dome menu To enter the menu of the speed dome please press the button A and MENU button into PTZ menu with a CAM message Press again or MODE button to release Use the A Y buttons to navigate through the menu Push the menu button to open the sub item Use the lt P buttons to change the settings Follow the operation instructions of the speed dome for further changes Save and call presets Push the Wand MENU button to open the preset menu use the MODE button to navigate through the sub items CBC AMERICA Corp Save preset Set the desired position with the arrow keys and then switch to the menu item save preset Press first the MENU button now you can choose the desired preset number With the A and YW buttons you can change the preset number gradually With the lt and gt buttons you can change the preset number in tenner steps Push the menu button to save the preset Call preset To call an already saved preset position change to the sub item call preset Choose the required preset number and confirm it with the MENU button You have also the possibility to start a tour that is already programmed in the speed dome Please refer to the predefined preset of the speed dome Follow the operation instructions of the speed dome for further information PTZ Speed With this menu item you can adjust th
7. robe for DC AC Voltage Measurement CBC AMERICA Corp Functions amp Operation Type A Measurement 1 Video Level a Power On device and push MODE key to go to the VIDEO page b Connect Video Out of device with Video In yellow BNC connector on video extension cord to measure the video level c System will auto detect NTSC PAL video signal and the measured voltage value will be shown as below 2 AC DC Voltage a Switch MODE key to AC150V 250V AC20V 150V or DC page b Connect two ends of termination with probe to measure voltage Caution While in DC measurement mode it is important to distinguish between the positive and negative leads c The measured voltage will be indicated on screen as shown below CBC AMERICA Corp Type B Tester 3 PTZ Control Test a Switch MODE key to get RS485 page as shown below b Push the MENU key to enter the Protocol Setup c Make sure that the remote PTZ device protocol is set correctly then configure the tester using the same protocol Example Protocol PELCO P Unit ID 01 Baud Rate 9600 d Control the direction of the PTZ camera using the Directional Buttons Press Up Right key for Zoom In Down Left key for Zoom Out View on monitor indicates that RS 485 communication is working 3 1 PTZ control test Call PTZ menu and call preset Before you can start to
Download Pdf Manuals
Related Search
Related Contents
設 計 書 学 生 募 集 要 項 - 大学院 統合新領域学府 Automated Disaster Recovery User Guide INTERNATIONAL® Kam K-UV 18X1W Strip manual v1 21-08-14 Welcome to Inner Balance Balance ASSMANN Electronic AK-1512-200 networking cable Manual de instrucciones Manual de instrucciones Samsung ND022LHXEA User Manual Copyright © All rights reserved.