Agilent 16048D Test Leads Operation and Service Manual

image

Contents

1. Agilent 16048D Test Leads Operation and Service Manual Fourth Edition Agilent Technologies Japan Ltd Agilent PN 16048 90031 RE Agilent Technologies May 2000 Printed in Japan NOTE Notices The information contained in this document is subject to change without notice This document contains proprietary information that is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated to another language without the prior written consent of the Agilent Technologies Agilent Technologies Japan LTD Component Test PGU Kobe 1 3 2 Murotani Nishi Ku Kobe shi Hyogo 651 2241 Japan O Copyright 1990 1998 1999 2000 Agilent Technologies Japan LTD Manual Printing History The manual s printing date and part number indicate its current edition The printing date changes when a new edition is printed Minor corrections and updates that are incorporated at reprint do not cause the date to change The manual part number changes when extensive technical changes are incorporated 1990 First Edition November 1998 Second Edition August 1999 Third Edition part number 16048 90031 May 2000 Fourth Edition part number 16048 90031 Safety Summary The following general safety precautions must be observed during all phases of operation service and repair of this instrument Failure to comply with these precautions or with specific WARNINGS elsewhere in this
2. e information about Agilent Technologies test and measurement products applications services and for a current sales office listing visit our web site http www agilent com find tmdir You can also contact one of the following centers and ask for a test and measurement sales representative 11 29 99 United States fax 61 3 9272 0749 Agilent Technologies tel 0 800 738 378 New Zealand Test and Measurement Call Center fax 64 4 802 6881 P O Box 4026 Englewood CO 80155 4026 Asia Pacific tel 1 800 452 4844 Agilent Technologies 24 F Cityplaza One 1111 King s Road Canada Taikoo Shing Hong Kong Agilent Technologies Canada Inc tel 852 3197 7777 5150 Spectrum Way fax 852 2506 9284 Mississauga Ontario LAW 5GI tel 1 877 894 4414 Europe Agilent Technologies Test amp Measurement European Marketing Organization P O Box 999 1180 AZ Amstelveen The Netherlands tel 31 20 547 9999 Japan Agilent Technologies Japan Ltd Call Center 9 1 Takakura Cho Hachioji Shi Tokyo 192 8510 Japan tel 81 426 56 7832 fax 81 426 56 7840 Latin America Agilent Technologies Latin American Region Headquarters 5200 Blue Lagoon Drive Suite 950 Miami Florida 33126 U S A tel 305 267 4245 fax 305 267 4286 Australia New Zealand Agilent Technologies Australia Pty Ltd 347 Burwood Highway Forest Hill Victoria 3131 tel 1 800 629 485 Australia
3. entification Chapter 2 47 Table 2 1 Service Maintenance Parts Identification Reference pant Qty Description 1 4 SLEEVE METAL 2 T 4 NUT 3 4 NUT HEX 4 T 4 WASHER FL MTLC 5 4 WASHER FL NM 6 0400 0203 1 GROMMET RND 7 16048 61612 1 WIRE ASSEMBLY 8 1 BOTTOM COVER 9 4 INSULATOR 10 l 2 CONNECTOR BNC 11 2 BNC ASSEMBLY 12 2200 0103 1 SCREW MACH 4 40 13 2190 0206 1 WASHER FL MTLC 14 16047 40000 1 STOPPER 15 16048 04011 1 TOP COVER 16 2360 0192 3 SCREW MACH 6 32 17 1400 0719 2 CABLE TIE 18 3 GROMMET RND 19 1 CABLE SHIELDED 20 1400 0493 1 CABLE TIE 21 16048 04013 1 TOP COVER 22 16048 04014 1 BOTTOM COVER 23 16048 61611 1 CABLE ASSEMBLY 24 4 BNC BOOT 25 4 SLEEVE 26 4 SLEEVE FLEX 081ID 27 4 INSULATOR 28 1250 0089 4 CONTACT RF CONN 29 1250 0052 4 CONNECTOR RF BNC 18 Chapter 2 Chapter 2 Service Maintenance Reference Description 16048 600202 1 TEST LEAD 1 thru 29 30 1250 0118 4 CONNECTOR RF BNC 31 2360 0115 SCREW MACH 6 32 32 16032 10021 1 PLATE 33 2190 0016 4 WASHER LK INTL T 34 2950 0001 4 NUT HEX 35 16032 10022 1 PLATE SHIELD 36 16032 60001 1 BNC BRACKET 30 thru 35 a Agilent internal only part number Not separately replaceable 19 REGIONAL SALES AND SUPPORT OFFICES For mor
4. es To compensate for or negate these residuals to minimize measurement error the instrument s Open Short compensation procedure should be performed The procedure is given in the instrument s operating manual 12 Chapter 1 NOTE Operation Operation Operation Setup and measurement procedure is as follows 1 Connect the 16048D directly to the UNKNOWN terminals of the instrument 2 Connect the user fabricated test fixture to the test leads 3 Perform Open Short compensation as described in the instrument s operation manual 4 Connect the DUT to the test fixture Connect the green lead to the chassis or grounded part on the test fixture to reduce the effects of stray capacitance between the DUT and the test fixture Chapter 1 13 Operation Operation 14 Chapter 1 Service Service Maintenance Maintenance An exploded view of the 16048D for parts identification is shown in Figure 2 1 Do not disassemble any further than shown Maintenance consists principally of cleaning contacts and replacing worn or damaged parts Take special care when cleaning contacts To order parts use the Agilent Technologies part numbers listed in Table 2 1 If a faulty part is located in an assembly that cannot be disassembled order the next higher assembly or return the whole device to the nearest Agilent Technologies Sales Service Office for repair or replacement 16 Chapter 2 Service Maintenance Figure 2 1 Parts Id
5. manual may impair the protection provided by the equipment In addition it violates safety standards of design manufacture and intended use of the instrument The Agilent Technologies assumes no liability for the customer s failure to comply with these requirements 16048D comply with INSTALLATION CATEGORY I and POLLUTION DEGREE 2 in IEC61010 1 16048D are INDOOR USE product WARNING Ground The Instrument To avoid electric shock hazard the instrument chassis and cabinet must be connected to a safety earth ground by the supplied power cable with earth blade DO NOT Operate In An Explosive Atmosphere Do not operate the instrument in the presence of flammable gasses or fumes Operation of any electrical instrument in such an environment constitutes a definite safety hazard Keep Away From Live Circuits Operating personnel must not remove instrument covers Component replacement and internal adjustments must be made by qualified maintenance personnel Do not replace components with the power cable connected Under certain conditions dangerous voltages may exist even with the power cable removed To avoid injuries always disconnect power and discharge circuits before touching them DO NOT Service Or Adjust Alone Do not attempt internal service or adjustment unless another person capable of rendering first aid and resuscitation is present DONOT Substitute Parts Or Modify Instrument Because of the danger of int
6. replace products that prove to be defective For warranty service or repair this product must be returned to a service facility designated by Agilent Technologies Buyer shall prepay shipping charges to Agilent Technologies and Agilent Technologies shall pay shipping charges to return the product to Buyer However Buyer shall pay all shipping charges duties and taxes for products returned to Agilent Technologies from another country Agilent Technologies warrants that its software and firmware designated by Agilent Technologies for use with an instrument will execute its programming instruction when property installed on that instrument Agilent Technologies does not warrant that the operation of the instrument or software or firmware will be uninterrupted or error free Limitation Of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by Buyer Buyer supplied software or interfacing unauthorized modification or misuse operation outside the environmental specifications for the product or improper site preparation or maintenance No other warranty is expressed or implied Agilent Technologies specifically disclaims the implied warranties of merchantability and fitness for a particular purpose Exclusive Remedies The remedies provided herein are buyer s sole and exclusive remedies Agilent Technologies shall not be liable for any direct indirect special incidental or con
7. roducing additional hazards do not install substitute parts or perform unauthorized modifications to the instrument Return the instrument to a Agilent Technologies Sales and Service Office for service and repair to ensure that safety features are maintained Dangerous Procedure Warnings Warnings such as the example below precede potentially dangerous procedures throughout this manual Instructions contained in the warnings must be followed Dangerous voltages capable of causing death are presenting this instrument Use extreme caution when handling testing and adjusting this instrument Certification Agilent Technologies certifies that this product met its published specifications at the time of shipment from the factory Agilent Technologies further certifies that its calibration measurements are traceable to the United States National Institute of Standards and Technology to the extent allowed by the Institution s calibration facility or to the calibration facilities of other International Standards Organization members IMPORTANT Warranty This Agilent Technologies instrument product is warranted against defects in material and workmanship for a period corresponding to the individual warranty periods of its component products Instruments are warranted for a period of one year Fixtures and adapters are warranted for a period of 90 days During the warranty period Agilent Technologies will at its option either repair or
8. sequential damages whether based on contract tort or any other legal theory WARNING CAUTION NOTE Assistance Product maintenance agreements and other customer assistance agreements are available for Agilent Technologies products For any assistance contact your nearest Agilent Technologies Sales and Service Office Addresses are provided at the back of this manual Safety Symbol General definitions of safety symbols used on the instrument or in manuals are listed below Instruction Manual symbol the product is marked with this symbol when it is necessary for the user to refer to the instrument manual This warning sign denotes a hazard It calls attention to a procedure practice condition or the like which if not correctly performed or adhered to could result in injury or death to personnel This Caution sign denotes a hazard It calls attention to a procedure practice condition or the like which if not correctly performed or adhered to could result in damage to or destruction of part or all of the product Note denotes important information It calls attention to a procedure practice condition or the like which is essential to highlight Contents 1 Operation Product Description rennen 10 Specifications ee yes Bee aa ee 11 Compensation for Fixture Residual Impedance 12 A era ee le 13 2 Service 16 Maintenance A Rehau Contents Operation This opera
9. ting note provides complete information on the 16048D Test Leads The 16048D is shown pictorially in Figure 1 1 its physical dimensions are given in Table 1 1 To order additional copies of this operating note use the part number listed on the rear cover Figure 1 1 Operation Product Description Product Description The 16048D consists of a direct attachment 4 terminal pair type fixture which is equipped with four BNC m terminated coaxial test leads These test leads are used to attach user fabricated test fixtures DC bias levels of up to 4 40V can be applied to the 16048D Cable length is 2 meter The 16048D is shown in Figure 1 1 Product Overview 10 Chapter 1 Operation Specifications Specifications Table 1 1 Specifications of the 16048D Function 4 terminal pair type fixture which is equipped with four BNC m terminated coaxial test leads Connector Type BNC male Maximum Voltage 40 V peak max AC DC Cable Length 2m Weight 460 g Safety Standards EN61010 1 1993 A2 1995 IEC61010 1 1990 A1 1992 A2 1995 CSA C22 2 No 1010 1 1992 INSTALLATION CATEGORY I POLLUTION DEGREE 2 INDOOR USE Chapter 1 11 Operation Compensation for Fixture Residual Impedance Error Compensation for Fixture Residual Impedance Error The 16048D has inherent stray capacitance residual inductance and residual resistance that affect the accuracy of measured valu