1. e Imported 19 Automatic Impression mixing Motorized automatic Impression mixing system system Elastomeric Impression Easy push button dispensing Material with two pouches of e Fast and homogeneous mixing for void free Polyether material impressions Hygienic direct filling of trays and syringes to avoid cross contamination e Less waste dispenses only amount of material needed Cartridge exchange Automatic retract Two pouches polyether dispensing tips for 200 impressions Three years warranty 20 Automatic processor e Processes all sizes and types of intra oral x ray film e High quality archivable radiographs are delivered dry in four minutes e Endodontic films may be viewed wet in only 60 or 120 seconds e Optional easy to use daylight loader eliminates the need for a darkroom e Films are processed automatically on insertion into processor e Unique film transport system ensures consistently excellent results e Electronic management system shows machine status and useful help codes e Compact dimensions simple installation and minimal servicing Electronic machine management Stand by mode Daylight Operation Deep processing tanks Routine chemical replacement and cleaning are quick and straightforward and the entire machine is designed for long life maximum reliability e With Three Year Warranty 21 Automatic shoe cover dispenser With a shoe cover storage box packing 200
2. 2 filter 15 watt bulb 69 Dark room timer Shows minutes and seconds in total darkness The 60 minute time range can be set in minutes for developing and seconds for enlarging control Two hands permit quick setting by seconds minutes or combinations of seconds and minutes Two separate outlet receptacles control an enlarger or printer and safelight by a combination time focus switch This model also can be used with a relay for heavier loads Easy to read numerals on a large 6 1 2 diameter face Luminated by phosphor fluorescence with digital display 70 Day light loader Compatible with DURR XR24 Easy processor to accommodate OPG and skull films 71 Debonding Pliers For the removal of brackets and adhesive residues 45 angled cutting surface Hard metal inserts Light weight Stainless steel imported 72 Dental Dewaxing Unit Double walled acrylizer inside made of stainless steel 304 grade and out side mild steel sheet with stoving paint The gap between the walls filled with glass wool to minimize loss of temperature 20 Temperature controlled by hydraulic thermostat from 5 C above ambient to 100 C with a sensitivity of 45 C Having a timer which could be set upto 2 hours S S drain plug 2 pilot lamps contorl knob ON OFF switch To work on 220 230 volts AC 73 Dentulous mould primary Highly flexible silicone rubber make
3. 215 Rectangular archwire bending plier Ideal for forming square rectangular archwires e Thin jaws are parallel at 020 opening Forms offsets and 90 bends on all types of arch wire Stainless steel Imported 216 Ribbon Arch Plier Designed for arch forming for placing 1 2 4 34 order bends blade width 0 070 wire upto0 022X0 025 Stainless steel Imported 217 Rongeurs 5 mm tip Stainless steel autoclavable imported 218 Rubber base gun for 50ml automix cartridges M ESPE GC Coltene similar 219 Rubber bowl Medium size Flexible plastic materials washable for repeated use Indian 30 220 Rubber dam complete kit Dental dam complete kit winged amp wingless with colour 38 coded clamps punch template amp retainer Hygienic similar 221 Self Adhesive electrodes for Reusable round approx 32mm _ diameter 100 TENS AND 5 UNIT compatible with the above mentioned TENS and E M S Unit 222 Semi automatic microtome The instrument should have Motorised feeding 1 system with manual sectioning with rocking mode facility and ability for voltage selection 2 hand wheel brake separate control panel for display Blade Holder Disposables blades Low Profile Vee insert for round specimens and universal block holder with following specification 1 Section thickness setting 0 5 to 100 um 2 Setting valu
4. Automatic Vacuum Breaker is provided to break the vacuum in case of formation of vacuum due to steam condensation Automatic Low Water Level Cut off Device fitted for general safety of the element Fitted with Automatic Pressure Control Switch Fitted with Dial thermometer to indicate the inner chamber temperature Lid is made of S S plate provided with radial locking system 125 Hot Plate Stainless steel Indian hot plate spatula 10 126 Hot water sterilizer boiler type Medium size stainless steel non corrosive with auto cut off 127 HOW Plier Straight 2 5mm tips Matching serrated pads assure a firm positive grip Rounded tips for patient comfort and safety Stainless steel Imported 128 HOW Plier Curved Curved beaks increase efficiency in posterior area Box joint Stainless steel Imported 129 Illumination system for Eye magnification loupes Imported portable illumination system With powerful LED light maximum details Easy to operate with temperature regulation Lightweight Compact Comfortable to wear for daily use Must fit in to supplement eye magnification loupes Two brightness levels with optimum light distribution without color gradients Maximum 8 hours of operating time Rechargeable battery supply unit compatible with common disinfectant solution to visualize 130 Impression trays Dentulous perforated Rim locked metallic
5. For insertion amp removal of arch wire Tips should be angled and serrated for better grip Stainless steel Imported 276 Welder The 660 XP Multi Purpose Welder is a small versatile economical chairside unit created to fulfill the multi purpose requirements of appliance fabrication It occupies minimum counter space and its light weight makes it appropriate for chairside or mobile use Electrodes align automatically and accessories add versatility to appliance fabrication Black color only It carries the CE mark which satisfies the most stringent technical and safety regulations Electrical size and weight data Solid state circuitry Size 6 1 2 wide x 10 1 2 deep x 6 7 8 high 16 5cm x 26 7cm x 17 4cm Net weight 8 Ibs 12 oz 4 0 kg Imported 277 Wheel Chair folding Features Robust Steel Framework Double X Brace hinges assembly With Arm rest and Foot Rest 150mm solid front castor s Rear solid Rubber tyres Seat and Back of Tetron Fabric Hand Brakes A support Belt provided at Footrest level Measurement 1045mm L x 680 mm W cx 910 mm H seat size 425mm x 425mm x 425mm 278 WHO probe CPITN C probe Ash Equinox clinical type with markings till 11 5mm single ended 15 279 William s periodontal probe Ash Equinox clinical type single ended Stainless steel Imported 220 280 Wire cutter heavy duty TC tipped Tungsten carbide insert maximum cutt
6. Stainless steel make sharp tip with good grip API or Similar 10 146 Lead Screen Movable X Ray barriers for operator and patient protection approximately 72 High x 28 Wide x 24 Deep Protection approx 0 5mm 8mm Pb 147 Lead storage box Composed of lead plate and iron plate The lead equivalent is not less 0 5mmpb 148 Ligature Tucker Straight notched tip at one end for anterior brackets Angled notched tip at other end for posteriorbrackets Slot in tips is chamfered to avoid breakage of ligaturewires Tips are smoothed to avoid hurting tissue Stainless steel Imported 149 Lingual Bracket Removing Plier Narrow sharp tips wedge between the edges of the bracket base amp tooth surface to remove direct bond brackets Stainless steel Imported 150 Lingual Cinch Back serrated tips of this instrument hold the wire securely while bending the wire 90 degree distal to the buccal tube Stainless steel Imported 151 Lingual Detailing Plier Ideal for bends bypasses and 2nd order bends Makes mm bends in out up down Stainless steel Imported 152 Lingual Double Ended Tucker Ligature director with One end notched one end curved For directing archwires and ligatures Stainless steel Imported 153 Lingual Flush Cut Distal End Safety hold Cutter with T C small To cut flush with the end of the buccal tube Minimum Cutting Capacity 012 30
7. 12 5x FOOT CONTROL PANEL Foot control panel with control keys for zoom and focus 191 Orban s knife Hu friedy Ash Equinox double ended 192 Orthodontic Bracket Positioning Digital Indicator and Caliper with clear LCD Device displays allowing bracket positioning up down by increments of 0 01mm Spring loaded Bracket Attachment Jaws Black granite stand measuring 280 x 200 x 40mm flatness 2 um Stainless steel Imported 193 Patient beds Mechanically Operated Back Rest Knee rest Trendelenburg Reverse Trendelenburg positions by Screw System Four sectional Uniformly Perforated CRCA Sheet Top Frame made of Strong Rectangular CRCA pipe ABS Bows S S Bows at Head and Foot End Powder Coated Half Length Collapsible Side Railing One IV Rod Height adjustable Four Revolving corner buffers Four 125 mm Castors Two with Brakes Four 125 mm Castors Two with Brakes Pre Treated and Epoxy Powder Coated 34 Bed size 210L x 100W x 60H cms High Quality 194 Patient shifting trolly Overall Size 180L x 56W x 81H cms Frame work made of tubular M S Pipe Swing away type Safety Side Railing Adjustable rod Utility Tray Cylinder Cage Removable Stretcher Top Foam padded Top Trolley mount on 15 cms Dia Costars Two with Brakes Epoxy Powder Coated Finish 195 Periodontal currette Set of Gracey curretes Stainless steel Imported 196
8. Indian 3 dentition 74 Dentulous moulds Mixed Highly flexible silicone rubber make Indian 11 Dentition 75 Dentulous moulds Permanent Highly flexible silicone rubber make Indian 4 Dentition 76 Diamond disc Double sided superflex with mandrel HP and 3 mandrel RA shank 77 Digital Calipers Large and clear LCD readout 2 Power on off Zero setting at any position inch mm switch 78 Digital Camera SLR Imported lens gt 10X zoom focus range 4 50cm infinity gt 14 megapixel monitor 2 7 3 inches LCD screen with Li ion rechargeable battery charging AC adaptor USB cable for data transfer audio video cable scratch card for camera screen with camera pouch bag 79 Digital radiography sensor With software Technical Specification for the 3 digital Sensor CCD based sensor 1 It should have a maximum pixel size of 19 microns 2 It should have a minimum of 26lp mm 3 It should have cesium iodide based scintillator and fiber optic layer between scintillator and the imager 4 It should be compatible with USB 2 High speed USB amp also network compatible 5 It should have user friendly software with trabacular enhancement interactive 3D and with pre calibrated sensor for endodontic implant measurements 6 Software should be DICOM compatible to save different formats of images ie CT Scans Digital OPG s intra oral camera photo cameras 80 Disinfectant Generating System Mixed oxidant solution generat
9. PLACE SEAL 52 ANNEXURE VII FORMAT FOR OTHER INFORMATION To be filled in by the bidder Cost of Tender Rs 500 Cash receipt Bank Draft No Date 1 Name of the P 3 Telephone Mobile No 4 Fak aus a maway qqaas aus if S PAN 3 ayasa T aqu heq uquy eR attach photocopy 9 Earnest Money Bids Security 3 of the estimated value of the goods to be provided a Bank Draft Pay Order No b Date For Rs d Drawn Signature of the authorised person Name of contact person Name of Firm Contact No Seal 53
10. Periodontal Probes WHO amp Williams Stainless steel Imported 197 Periosteal elevator Hu friedy Ash Equinox Small headed double ended Stainless steel Imported 19 198 Periosteal elevator small Hu friedy Ash Equinox Small headed double ended Stainless steel Imported 10 199 Piezoelectric bone cutting unit ultrasonic surgical system with handpieces and associated tips for cutting bone and bone substitutes Progressive multifunction foot pedal LED handpiece of atleast 60 watts of power Four power setting modes 3 for bone cutting based on bone density and 1 for soft tissue detachment Cutting tips Console touch sensitive LCD screen Cable connectors for atleast two hand pieces with Two peristaltic pump housings Two brackets for irrigation solution 200 Pin amp Ligature Cutter Accuracy right to the tip for smooth cutting of soft ligature wires With hard metal tips replaceable by the manufacturer Sharpening of inserts possible by the manufacturer We do not recommend using the front third of the cutters for cutting wires with the maximum indicated thickness max wire thickness 0 4 mm soft Concave design front for maximum vision when cutting used for cutting pins and ligatures Stainless steel with TC tip Imported 201 Plaster cutter Metallic spring loaded Hu Frie Henry Schien similar dy 202 Plaster dispenser Electrical
11. Small head for better access and visibility within the oral cavity A wide variety of handpieces both tip and tip less a nondisposable option as well as various application tips Handpieces should be autoclavable up to 135 C 275 F Laser Type Erbium YAG Wavelength 2940 nm Pulse Energy up to 700 mJ Power up to 8 4 Watts on tissue Mode Hard and Soft Tissue Pulsed Frequency 10Hz 50 Hz Energy Transmission Direct Delivery System Spot Size 0 2 1 3 mm Electrical Multi Range 100 230 V AC 13A 5060 Hz single phase Sterility Autoclavable Handpiece and Tips Handpiece 360 Swivel Lightweight 123 Hook crimping plier Tip with V shaped notch for holding and crimping sliding clamping and stop tubes Designed to crimp auxillary stops hooks and posts to archwire The slotted design fits over the base of the hook while holding it tight 27 during crimping Stainless steel Imported 124 Horizontal autoclave 135 Ltr Double walled unit horizontally mounted on a sturdy heavy M S duly painted or stainless steel tubular stand Both inner chamber and outer wall made of S S Pressure adjustable from 10 20psi Fitted with pressure gauge safety valve and steam release valve Avallable with separate boiler For units fitted with S S Boiler separate valves for injecting the steam into the main chamber and releasing the steam in atmosphere after use are provided
12. 1 push button air turbine with handpiece Bein Ait W amp H Similar Should have inbuild piezon scaler EMS Satalac Similar Should have LED air cooled light cure unit on assistant side Should have 3 functional 3 way syringes Should have 3 functional 3 way syringes on assistant side also Should have original TFT swivel clamp Should have auto drain motorized suction 180 Mouth Mirrors Rhodium coated anti mist with handle Mouth Mirrors Rhodium coated anti mist Durable stainless steel Light weight Imported 1820 181 Multi Purpose Orthodontic Welder Imported Feather type finger switch progressive heat station for welding and auxiliary functions Turret with one soldering and 4 welding electrode combination Flexible soldering cable Annealing jack Foot switch welding and soldering 32 182 Naber s furcation probe Double ended autoclavable color coded at 60 3mm band 183 Nance Loop forming Plier Precision loop forming with four step tip 5 3 4 5 and 6mm Serrated tips prevent wire slippage Stainless steel Imported 184 Needle Burner with syringe Compact Device Portable Very high grade 6 imported steel cutter which does not rust or becomes blunt even after long usage Removable discharge tray for disposal of needle ash and syringe hubs Shock proof amp fuse protection 185 Needle holder Good quality rust proof steel med
13. 3 4 5 6 7 8 9 10 11 12 13 14 Each 118 Gracey mini curettes Hu friedy Ash Equinox double ended 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Each 119 Gutta Percha Cutter Cordless device with interchangeable tips for fast precise and safe cutting of excess Gutta Percha The loop on the cutting tip should provide easy access to the cavity and should catch the excess gutta percha exactly at the canal orifice and precisely cuts it off Fast recharging of the Ni Cad power battery in the charging unit 120 Haematology autoanalyzer e Should be fully automated haematology analyzer providing 18 parameters including a 3 Parts differential with user definable settings for RDW CV and RDW SD e system should give the differential count as Lymphocytes mixed population neutrophils while mixed population should include Eosinophils Basophils and Monocytes e The system should be capable of processing samples at a speed of 60 samples hour e The system should be sample rotary valve SRV based for the precise sample aliquoting for dilutions 25 The system should have auto probe wiper to clean the sample probe automatically after sample aspiration The system should use non cyanide based reagent for Hb estimation System for the reliability of the results should have Electrical Impedence method of cell counting with an
14. Ash kavo similar plastic colour coded assorted sizes set of max amp mand 4 sizes each Set 14 131 Impression trays Edentulous perforated Rim locked metallic Ash kavo similar plastic colour coded assorted sizes set of max amp mand 4 sizes each 28 132 Instrument sterilization pouch amp sealing machine With dual cutting amp sealing action Thermostatically controlled heater Double blade cutter for easy amp smooth cutting With maximum cutting width 25cms Adjustable width reel holder Roll of sterilization paper pouches 133 Instrument tray Non perforated good quality aluminium with lid with slots for instrument keeping small size autoclavable 100 134 Intra oral camera 1 2 MP with software e It should have resolution of 680 000 pixels e It should have sensor 1 4 inch CCD e It should have lens 0 02inch pin lens e It should have 1 4 pictures to divide up and change e It should have memory of 27x4 pictures e It should have VGA amp USB2 0 signal output e It could be used direct on TFT without CPU e It should have 6 led for better visibility and image 135 Intra oral photography mirrors Set of 3 mirrors Rhodium coated front surface or highly mirror polished steel with anti fogging spray liquid lingual buccal occlusal for adult and pediatric 6 mirrors 136 Intra oral Sandblaster Micro etcher Etc
15. a particle retention efficiency of 99 95 and a bacterial challenge efficiency of 99 99 3m PVC suction tube Internal diameter 8 mm external 13mm Maximum pump flow 70 L min maximum vacuum 93kPa 933 mbar 700 mmHg PowerL 250W Voltage 200 240 V 50 60 Hz Available 100 120V Dimensions 960 x 430 x 340mm Weight 25 kg All parts coming into contact with secretion are autoclave safe 120V Dimensions 960 x 430 x 340mm Weight 25 kg All parts coming into contact with secretion are autoclave safe 269 UV Sterilizer e It should have original philips UV light e It should have 12 stainless steel trays e It should have a switch for auto light on off e It should have rusting proof body 270 V bend forming Plier Special design makes 1mm V bends to shorten arch wires or provide a positive stop Excellent for placing stops in nickel titanium wires Stainless steel Imported 271 Vibrator It should have 2 ring that are highly resistant to corrosion are electronically regulated with a removable rubber cover With 3 years warranty manufacturer 44 supplier 272 Ward screen Metal frame with green cloth partitions foldable with wheels casters 13 273 Wax Knife Double ended wooden handle Indian Steel API or Similar 30 274 Wax Spatula Double ended Indian Stainless Steel 30 275 Wein Gart Pliers
16. and compact e Wireless DC X ray e Rechargeable lithium polymer battery e 60 2 mA tube e With LCD display e JOPA film and RVG sensor compatible e Internally lead coated to prevent excess exposure and dispersion of radiation e With patient and tooth selection mode e Imported 209 Portable T E N S AND E M S Channel 4 electrodes Therapy unit Pulse rate 1 Hz to 150 Hz adjustable Pulse Width Adjustable from 50 to 300 microseconds us step On Time Adjustable Off Time Adjustable 0 90 seconds Ramp Time Adjustable Continuous 15min 30min 45min 60min selectable Power source Rechargeable batteries Weight light weight less than 500gms with battery Minimum 5 TENS modes Minimum 3 years warranty F D A approved 210 Posterior Band Removing Plier For removing molar bands Stainless steel With replaceable plastic tip With replaceable hard metal tip imported 211 Pressure moulding machine Medium wave time controlled infrared heater programmed cooling phase 2 bar working pressure range of plates foils of 0 1 3 0 mm heating of the material side which is placed directly over the model large model cup and ergonomic pellet container Simple functional one switch operation AC 230 V 115 V 340 W Pressure 0 1 2 0 bar Measurements 230 x 200 x 450 1 x w x h Weight not more than 7 5 kg 36 212 Projection microscope Specification of Projection microscope e Imported CE
17. be used with any available duplicating film e Minimum 3 years warranty 24 109 Film holder for Intra oral paralleling technique With position indicating device attachments for anterior and posterior teeth autoclavable Imported 110 Film holders For intra oral bisecting angle technique autoclavable imported 500 111 Flexible Denture Curing System Works with Heat cured Microwave Pour resins Silicone soft liners and Thermoplastics Injects Lucitone 199 Lucitone FRS for flexible partials Lucitone Fas Por pour acrylic Lucitone Clear acrylic Lucitone for quick set up and Luci Sof soft liner Includes Injection Unit Cartridge Sleeve Flask Leveler Flask Opener Allen Wrench Cartridge Plug Material Cartridge Injection Socket Pressure Piston Success Piston Caps Heat Seal Bags Sprue Wax Sticks Insulating Putty Laboratory Matrix Putty Starter Kit 112 Floating Thermometer For monitoring processing solution temperature Should not contain mercury Should be able to clip onto the tank 113 Formalin chamber Medium size 3 trays 114 Fox Plane Aluminum Fox plane 10 115 Frassica typodonts Pediatric Mixed dentition amp Adult 116 Glass bead sterilizer with beads Indian Make with beads auto cut AC 220v 117 Gracey curettes Hu friedy Ash Equinox double ended 1 2
18. friedy type sinus lift technique with a Bone Spreader convex straight 2 7 mm to 5mm Bone Spreader convex angulated 2 7 to 5mm width Bone Pusher straight 2 7 mm to 5mm Bone Pusher angulated 2 7 mm to 5mm width Bone Shaver concave straight 2 7 mm to 5 0 mm Universal handle an d cassettes 228 Slide box 5 slide Plastic boxes with 5 slots to the 12 histopathological slides with lockable lid 229 Small scissors Small sized Curved Light weight with durable 60 steel tip 230 Soft tissue laser system Power atleastl10 Watts Wave length 810 980 5 nm Touch Screen Monitor with password protection 22 preset treatment programs Facility to create and modify new old programs Wireless foot control should have both pulse and continuous mode User friendly software for more precision and faster surgery Long hours of battery backup Built up tutorials for first time laser users as guide for efficient usage High light emitting auto cooling ergonomic design digital technology weight less than 2 kg 3 years warranty Package should contain Laser unit 3 numbers of safety goggles spool fiber 200 and 400 micron autoclavable hand piece multiple tip fiber 25 Numbers of fiber tips bleaching accessories carrying case user manual procedure CD Hertz rate in pulse mode 1 5000Hz Pulse Interval 0 1ms 9 9s Pulse duration 0 1ms 9 9s Duty Cycle Adjustable Autoclave Hand Piece autoclavable AC 100 240V0 60 Hz Lithium Battery 3 7 4 2V
19. low temperature cycle Should be able to perform glazing chairside on metal ceramic layered ceramic pressable ceramic crown and bridge 57 Cheatel forceps Stainless Steel Corrosion resistance Dimensional accuracy Fine finish 17 58 Cheek Retractor Winged clear high quality Autoclavable plastic 11 59 Chisel Hu friedy Ash Equinox for bone cutting 60 Composite instrument kit Set of 6 instruments Durable stainless steel with Teflon coating Light weight Imported 33 61 Control box and foot pedal for micromotor e Jt should have minimum 0 35 000 RPM speed e It should have Forward amp Reverse direction selection function e It should be capable to operate through both Hand amp Foot e It should have high torque for smooth working 62 Cotton Drums Medium Autoclavable stainless steel make 63 Crown contouring pliers Stainless steel imported for stainless steel crowns contouring 64 Crown crimping pliers Stainless steel imported for metal crown modification 65 Crown trimming scissors For cutting bands and crowns Stainless steel imported 66 Curette Bruns Bone Curette Oval 000 67 Curved probe Explorer Stainless steel imported 1520 68 Dark Room Safelight X ray Safe light with filter for extraoral screen films blue green spectrum also safe light in red spectrum with
20. mix both samples and reagents during operation e Reagent Units Minimum 35 cooled reagent position should be available in reagent unit e Programmable Parameters Unlimited e Sample Dilution Should have facility of auto dilution e Water requirement Should not be more than 06 liters day e 21 Comprehensive onsite warranty for Five years followed by comprehensive on site AMC for next 5 yrs 6 10 Yrs e Rate list of different spares and consumables used in the machine must be provided in the price bid The startup kit should contain all reagents for 200 tests each and 2000 sample cups System Requirement Inbuilt Laser Printer Monitor PC P4 System interface Serial RS232 and LAN TCP IP e Cost of proprietary reagents to be quoted e Approximate cost per test to be indicated 40 Biostar VI Versatile pressure moulding machine WITH with convenient bar code scanner Extra deep model cup for embedding mounted models Reaches working temperature in 1 second Voltage 110 220 W 50 60 Hz Power 850 W Work Presser 6 bar 87 psi WxDxH 18 x10 x10 25 Weight 35 LBS 16 Kg Fuse Two 5x20mm 8 amp Heating Element Presser Chamber Locking handle Clamping Frame Pellet drawer Bar Code Scanner Plug with fuse Presser Controller Compressed air connection On off switch Code Button Air button CE button Time button Code Heating time Imported 41 Bleaching un
21. right arm rest and double articulated head rest Should have aluminum alloy chair to prevent rusting Should have atleast 4 programmable working positions Should have preset auto return to zero spitting and last working position Should have chair movement control from assistant side also Should have a preprogrammed trendelemburg position for dental emergency Should have synchronized movement of seat and back rest Should have independent up down movements Should have safety system on chair base and backrest to prevent damage Should have 3 axis rotation of chair light Should have 9 variable luminous intensity from 8000 lux to 35000 lux Should have fan in chair light assembly for cooling Should have easy to clean removable handles Should have continental delivery unit with overhead delivery Should have x ray viewer with automatic turn off Should have removable amp autoclavable resting silicon pads Should have high quality ceramic spittoon with programmable water input for spittoon amp cup Should have assistant instrument table fitted on articulated arm for suction Dental stools for doctor and assistant Should have a chair side trolley with modular components for storage Should have internal spray electric motor with rotating speed of 60 to 400000 rpm with internal spray contra angle amp st handpiece Bein air W amp H similer should have 1 fiber optic air turbine with handpiece Bein Ait W amp H Similer Should have
22. specific and valid for at Least 30 days 07 Sample Tray 30 positions for the bar coded patient samples including stat Positions with separate positions for Blank Calibration amp controls 08 Sample volume 2 70 ul 09 Sample Tubes Cups Most commonly used blood collection tubes Vacutainer 02ml 03 ml 05 ml etc and sample Cups including pediatric sample cups The machine should perform quality tests including L J plot be able to collate analyse quality control data Quality control memory stage should be of at least 3 levels Sample Types Serum Plasma Whole Blood C S F amp Urine Testing Item ALT AST ALP ACP GGT a HBDH LDH CK AMY TG TC HDL C LDL C UA UREA Cr GLU TP ALB T Nil D Bil TBA NH4 CO2 Ca Mg Cl Na K poAL apob LP a C3 C4IgG IgM HBAIC Alcohol Amphetamine Barbiturates Benzodiazepine etc Reaction Temperature 37 0 2 Degree Celsius Environment control The machine shall be capable of operating in 16 ambient temperature 20 30 Degree Celsius and relative humidity less than 10 e Photometry 8 Wavelengths 340 405 450 505 546 578 660 amp 700 nm Both Mono amp Bichromatic e Reaction system Reaction Rotor should be rotating tray containing permanent cuvette Reaction volume should between 150 to 500 e Machine should have single probe used for both sample and reagents The machine should be able to properly
23. 10AH Wireless Pedal 1 5V Battery Used for soft tissue surgery Implantology therapy Periodontology Endodontics aesthetics 231 Spirit Lamps Spirit Inflammable lamps 27 232 Spoon excavators Double ended good quality steel small and 188 medium sized working tips ends 233 Standard Head Cartridge for NSK original standard head for pana Air 20 NSK handpiece model 234 Steam cleaner e Automatic shut off with low water 1 light indicator e Use regular tap water 40 e Pressure gauge manometer 50 p s i operating pressure DRY STEAM 12 gauge heavy duty wiring Ceramic terminal block Stainless steel tank and outer casing Quick disconnect fittings for steam hose With 3 years warranty by manufacturer supplier 235 Stethoscope Noise Reduction technology and sound 2 amplification littmann or similar 236 Straight probe Durable stainless steel Light weight Imported 1320 237 Strip Holding Forceps For holding orthodontic abrasive strip 2 Diamond coated barrel tip 238 Surgical small scissors High quality steel sharp edges with fine tip 9 straight and curved 239 Surgical Bins Drums for SS make 13 autoclave 350 x 240 mm dimensions approx Latches present to lock 240 Surgical instrument trolley Overall size approx L x B x Ht 710mm 19 x 460mm x 830mm SS frame Trolley mounted on wheels 241 Surgical Kidney instruments tray F
24. Museum jars Made of glass with lids borosil make Ht x Lt x Br incm 27x25x12 36x 15x10 25x25x12 25x16 5x14 20 Oven Triple walled made of SS 304 range 500 400 C with accuracy of 2 C controlled by digital temp controller cum indicator pH meter 3 Digit LED display range dimensions 80mm H x 235mm W 150 MM L accuracy 0 02 pH 2 least count Rotor Remi centrifuge Remi centrifuge rotor with 8 and 12 slots model R4C 10 Slide boxes Plastic box of 100 slides two rows of 50 slots each 11 Slide storage cabinet for aprox 1000 slides Horizontal Acrylic cabinet with Removable ten plastic trays 9 x 100 mm with 100 slots for fitting slide each tray fitted with index holder Slots are numbered 1 50 Cabinet cover in clear acrylic 12 Specimen Buckets HDPE high density Polyethylene plastic Drums with full open top lids 15 Ltr 35 Ltr 75 Ltr 10 13 Spectrophotometer Digital readout of T O D Conc Source Helogen amp D2 lamp cut off filter IR Resolution 47 0 1 in T amp 0 00 in O D 1 in 999 for conc spectral bandwidth 3nm 3 position cuvette holder zero blank amp sample low volume sample I ml sleek corrosion proof fiber body with aluminum based 14 Stethoscope Ambient Noise Reduction technology and sou
25. PA oblique submento vertex carpus Acquisition format size upto cm 18x18 18x24 24x24 24x30 30x30 X Ray Generator and Other Specifications Tube voltage 60 90 kV Tube current 2 15 mA Frequency 140 kHz Tube focal spot 0 7 mm IEC 60336 Input voltage AC 1 With lead lined console room 1 7mm lead equivalent with lead viewing glass of size 30inches x 25 inches 2mm lead equivalent With three year warranty A E R B approved x ray machine 54 Cement Spatula Double sided for mixing dental cements 110 Durable stainless steel Light weight Imported 55 Chair side cabinets e It should be made up of high quality 28 powder coated steel frame of minimum 1 0 mm thickness preferably double steel layer e It should have different drawer compartment for storage of different instruments with plastic trays for different Dental instruments and materials e The top should be made of durable artificial marble which is easy to clean e It should have moulded type joint free wash basin incorporated with the artificial marble top e It should have Multi functional shelf which can be used to store small equipments e Jt should be supplied with mobile dental cabinet in steel with coloured glass top and a lock e Minimum dimension 2250 490 855 mm 19 56 Chairside Porcelain glazing unit Chairside glazing of ceramic crown amp bridge table mount programmable chairside glazing unit
26. TENDER NO 02 FOD EQPT JMI 2013 14 Tender for Procurement of Equipments Instruments for Faculty of Dentistry JMI Dated 23 04 2013 OFFICE OF THE DEAN FACULTY OF DENTISTRY JAMIA MILLIA ISLAMIA JAMIA NAGAR NEW DELHI 110025 TELEPHONE FAX 011 26983046 1 CONTENTS S No PARTICULARS PAGE No 1 TENDER NOTICE 3 2 INSTRUCTION TO BIDDERS 4 5 3 CONDITIONS OF CONTRACT ANNEXURE I 6 9 4 FORMAT OF SCHEDULE OF REQUIREMENT 10 ANNEXURE ID 5 SPECIFICATIONS AND ALLIED TECHNICAL DETAILS 11 48 ANNEXURE HD 6 PRICE BID SCHEDULE ANNEXURE IV 49 7 SELF DELCARATION FORM ANNEXURE V 50 7 CONTRACT FORM ANNEXURE VI 51 52 FORMAT FOR OTHER INFORMATION ANNEXURE 53 Jamia Millia Islamia Jamia Nagar New Delhi 110025 Ph 26982759 Tender Notice Sealed Tenders are invited from reputed companies authorized _ dealers distributors for purchase of equipments instruments for the Faculty of Dentistry as per details given in the Tender Document The Tender document with other terms amp conditions can be downloaded from JMI website www jmi ac in Last date for submission of tender 22 05 2013 by 01 00 pm at Faculty of Dentistry JMI Opening of Technical bids 23 05 2013 at 3 30 pm at Faculty of Dentistry JMI Sd Date 23 04 2013 Registrar For publication in the minimum size in the tender notice Column 1 The Indian Express Instructions to Bidder
27. a Millia Islamia Jamia Nagar New Delhi 110025 We the undersigned Tenderer having carefully read and examined in detail the Terms and Conditions specifications and all bidding document in regard to the supply of equipments instruments at Jamia Millia Islamia and accept the same We also do hereby declare 1 that we have not been blacklisted debarred by any Government Undertaking 2 that the rates quoted are not higher than the rates quoted for same item to any Government Undertaking 3 that the tender submitted by us is properly sealed and prepared so as to prevent any subsequent alteration and replacement For and on behalf of the firm Firms Name amp Address Signature of Authorized Signatory Name Designation Phone No Seal Dates acd Place 50 ANNEXURE VI CONTRACT FORM to be filled by the successful bidder THIS AGREEMENT made the of 20 between the Registrar Jamia Millia Islamia New Delhi hereinafter called the Purchaser of the one part ANG Name of Supplier of City and Country of Supplier hereinafter called the Supplier of the other part WHEREAS the Purchaser is desirous that certain equipment instrument and after sales services Brief Description of equipment instrument and after sales services and has accepted a tender by the Supplier for the su
28. ame make and same or better configurations as were originally there in the equipments shall be used The supplier vendor shall maintain details of the replacements and repairs carried out if any in any equipment instrument in a separate document and produce the details as and when required by the user department of JMI The cost of the parts will be borne by the supplier In case of complaint regarding repairing replacement of equipment instrument within the watranty period the supplier will provide repair replacement immediately In case of non compliance or delayed compliance supplier will be penalized with an amount mutually agreed upon and it would be deducted from the Bank Guarantee The technical specification wherever given in the items specification format is basic The equipments instruments may also be evaluated as per additional provisions and facilities Payment shall be made after submission of the invoice Bank Guarantee and successful installation Jamia Millia Islamia a Central University is exempted from Customs Duty Central Excise Duty If required a copy of the certificate will be issued by JMI Delivery should be within specified days mentioned in Purchase Order issued by PICO JMI If the equipment instrument are not delivered within the stipulated time the supplier shall be liable to pay a penalty of 1 of the total order value for each delay of 10 days or part thereof and the amount will be deducted from the
29. and FDA certification Onsite service 3 year comprehensive warranty Demonstration of the equipment must be provided prior to purchase Microscope specifications e Eyepiece Locked WF10X 18mm e Nosepiece Quatruple revolving with positive click stops e Standard ObjectivesMotic 4x 10x 40x 100x e Stage Built in Mechanical Stage with low position coaxial controls e Condenser Spiral mount focusable 1 25N A Abbe Condenser e Illumination 12 20 Halogen with dimming control e Power Supply Variable Voltage Power Supply 110V 240V e Camera specifications Chip Configuration Built in Live 1 3MP Imaging Chip e Data Output USB2 0 e Power Supply Through USB Cable from Computer e Included Software PC and for Macintosh e Included Accessories Calibration Slide for accurate measurements Dust Cover Immersion Oil 213 Pulp tester e It should be capable to tests pulp vitality of an injured non injured tooth e It should have three Preset speed mode high mid low speed e It should be easy to operate e It should have specifically designed for patient comfort e It should be Convenient to operate e It should have Maximum stimulus 80 e It should have automatic off function after three minutes e It should be operated through 9 Volt long life high output batteries 214 Pulse oximeter Should have following features Light and compact handheld design High resolution 2 4 color display Rotatin
30. any delay loss or non receipt of tender documents sent by post The Vice Chancellor JMI shall be the final Authority for settlement of any dispute and the jurisdiction of Court of Law shall be Delhi New Delhi ANNEXURE II FORMAT OF SCHEDULE OF REQUIREMENTS All columns to be filled by supplier S No Name Equipment Instrument of Unit Qty Delivery Schedule EMD Rupees in Delivery in weeks at the user department JMI 10 Authorized Signatory Name Designation Name of the firm Seal ANNEXURE SPECIFICATIONS amp ALLIED TECHNICAL DETAILS S No Name of Items Specification Estimated Quantity Bidders Compliance Complied Not Complied Acrylizer Double walled acrylizer inside made of stainless steel 304 grade and outside mild steel sheet with stoving paint The gap between the walls filled with glass wool to minimize loss of temperature Temperature controlled by hydraulic thermostat from 5 C above ambient to 100 C with a sensitivity of 45 C Having a timer which could be set upto 2 hours S S drain plug 2 pilot lamps control knob ON OFF switch To work on 220 230 volts AC Adams Plier With two smooth rectangular beaks Tungsten carbide coated working faces that can be replaced in the factory Length 12 0 cm Imported 10 Agate Spatula Durable Light weight High quality plastic make Should no
31. at least 2 Govt institutions In NCR and provided evidence of the same in the technical bids 26 e The firm should have adequate facility to provide proper warranty and maintenance of the equipment Firm should also have service engineer based in New Delhi for this purpose e The machine should be operable with normal power supply input 220 240 V AC and 50 Hz available at the Health Centre Electrical safety standard should confirm to IEC IS 13450 e The machine should have facility for flagging of abnormal results amp user programmable ranges e Documentation e Certificate of Calibration and inspection e User manual amp service manual in English e Log Book with instruction for daily weekly monthly and quarterly maintenance checklist The job description of the hospital technician and company service engineer should be clearly spelt out 121 Half Round plier One round beak and other concave beak round beak fits into concave opposite beak For especially fine bendings With individually replaceable hard metal tip max wire thickness 0 5 mm hard Stainless steel Imported 122 Hard Tissue Laser The laser unit should be Light weight and compact Laser should have fast cutting facility Laser should be in the Handpiece itself 360 swivel head for complete freedom of movement within the oral cavity Flexible cable for maximum treatment angles and feather touch accuracy
32. ble hard metal tip imported 35 Band removing plier posterior Long chisel tip with carbide insert e Facilitates removal of posterior bands e With replaceable occlusal nylon pads For removing molar bands Stainless steel With replaceable plastic tip With replaceable hard metal tip imported 36 Bard parker handles Ash Equinox Straight and angulated round handles imported quality 37 Base former Upper amp Lower Adult amp Mixed Dentition Made up of silicone rubber 38 Bedside Iv fluid stands e I V stand frame made of high quality CRCA SS plastic pipes 15 I V Stands with five spiked base on 5 cms castors Chrome plated adjustable rod with double hook LV stand of SS adjustable rod with four hooks is also available Pre Treated powder coated burn cage 39 Biochemistry autoanalyzer System Discrete open Automated Random access clinical chemistry analyzer should be USFDA approved Stat Analytics At least 5 stat positions should be available Throughput Photometric 100 to 150 tests hour Bar Code Identification Automatic Bar code scan for reagents and samples 05 Measuring Principles Colorimetry Rate amp end point kinetic Method and Turbidmetric Assay 06 Calibration Provision for automated Linear Non linear amp Multipoint Calibration should be available Calibration should be reagent
33. d date for the submission of tender being declared a holiday for the JMI the tender will be received up to the appointed time on the next working day 10 11 12 13 14 15 16 17 18 19 Prices shall be quoted in Indian Rupees for offers received for supply within India and in US dollars as per the Financial Bid format in case of offers received for supply from foreign countries Prices quoted should be FOB FOR JMI New Delhi inclusive of all charges required to make the equipment functional to the satisfaction of JMI otherwise it would be presumed that the quoted prices are inclusive of all charges if applicable In case price for imported goods are quoted in FOR the JMI will provide customs duty exemption certificate and the supplier should submit original Bill of Entry which must be in the name of the Registrar JMI All taxes if applicable should be quoted separately otherwise it would be presumed that the quoted prices are inclusive of taxes please see Financial Bid format The JMI may decide to open a letter of Credit or Wire Transfer in cases where it so decides Any variation in price from the importer and manufacturer be indicated well in advance The imported equipments should be quoted by the authorized supplier dealer In this case commitment of after sales service with the period applicable should be clearly mentioned The quotations must be valid for 180 days six months from the date
34. ed chemical irrigants powered by iPiezo engine Digitally controlled With tip changers Complete kit of scaling tips subgingival inserts and endo tips of all shapes amp sizes with polishing kit 43 Autoclavable tip holder Autoclavable box for tips With automatic cleaning function with polishing function Autoclavable hand pieces With Inbuilt compressor 264 Universal curettes each Hu friedy Ash Equinox 4R 4L 2R 2L double ended 265 Universal Bracket Altimeter Boons Gauge Autoclavable stainless steel metal Imported for precise bracket positioning 3 5 4 0 4 5 5 0 mm 266 Universal Plier Plier with round and square beak used for removable appliance Stainless steel Imported 11 267 Universal scaler Hu friedy Ash Equinox No 204 of 3 different sizes Stainless steel Imported 268 Universal suction machine With three modes to supply electricity alternating current and batteries Body highly resistant to shocks or resistant to shocks or scratches 4 very resistant wheels 1 of them antistatic and 2 of them with brakes On Off switch Suction control knob Cable length 3 m Pump Long life piston type oil free maintenance not required 1 or 2 PC4 collection jars polycarbonate 4 L scale up to 3 500 ml with safety valve to prevent overfilling 1 bacteria filter with each jar Hydrophobic PTFE filter It Guarantees
35. eight 22 inches Approx Length 64inches Approx With min 3 year warranty 46 SPECIFICATIONS amp ALLIED TECHNICAL DETAILS LIST OF THE MEDICAL E UIPMENTS S No Name of Items Specification Estimated Quantity Bidders Compliance Complied Not Complied BP apparatus ANEROID Shphygmomanometer ANEROID Sphygmomanometer Superior Quality Imported 30 Electronic balance Digital electronic balance capable of weighing upto 500 g Fume chemical hood Constant Volume no larger than 6 fit in length equipped with fume hood flow alarm The work surface of the benchis recessed 1 2 inch or more below the front edge of the bench and the sides and back of the bench are provided with a seamless vertical lip 1 2 inch high An airfoil with a 90 are with a minimum radius of 1 inch Incubator Temperature range 8 c above ambient to 60 capacity 12 cu Fit Microscope Binocular Binocular head 30 degree inclined 360 degree rotating wide field eyepieces 10 x 20 mm One eyepiece with pointer reverse mounted quadruple revolving nosepiece achromatic super contrast lens in objectives 4x 10x 40 x 100xoil Coaxial coarse and fine focussing system with tension adjustment built in low position coaxial mechanical stage Focusable condenser Numerical aperture 1 25 with iris diaphragm LED illumination 3W with intensity control Olympus similar 20
36. es 0 5 to 5 um in 0 5 um increments 5 to 20 um in 1 um increment 20 to 60 um in 5 um increment 60 to 100 in 10 um increment 3 Horizontal specimen feed 28 mm 1 mm feed motion via step motor 4 Coarse feed Motorised coarse feed in two steps i e 300 um sec and 900 um sec 5 Vertical specimen stroke length 70 mm 6 Specimen orientation Horizontal 8 deg Vertical 8 deg 7 Trimming Section thickness 1 to 600 um 8 Specimen retraction 5 to 100 um in 5 um increment can be turned off Voltage supply 230 V 50 60 Hz 10 Demonstration at installation site is required 11 Performance certificates from 3 government institutes who have purchased a similar model within last 2 years 12 50 nos low profile 50 nos of high profile disposable blades must be provided 13 5 year comprehensive warranty 223 Set of Extraction Elevators e Atleast 10 different elevators in 1 set 4 e Made of German Stainless steel e Rust Resistant Light weight e Imported 224 Set of Gracey currettes Universal Imported 2 225 Set of pedodontic extraction Set of 10 forceps or the upper and lower 5 forceps anterior and posterior Highest quality German stainless steel Imported 39 226 Short Cycle Autoclave High Speed Sterilization built in water 1 treatment system 227 Sinus lift osteotome set hu Osteotome Kit for the specific closed 1
37. ets Maxillary and mandibular made of plastic hinged Imported 89 Educational Model with Edwise Angle Class I Normal occlusion Brackets Fitted with metal edgewise brackets Maxillary and mandibular made of plastic hinged Imported Imported 90 Educational Model with Lingual Angle Class I Normal occlusion Brackets Fitted with lingual brackets Maxillary and mandibular made of plastic hinged Imported Imported 91 Educational Model with MBT Angle Class I Normal occlusion Brackets Fitted with MBT brackets Maxillary and mandibular made of plastic hinged Imported Imported 92 Educational Model with Self Angle Class I Normal occlusion Ligating Brackets Roth 22 Fitted with SELF LIGATING brackets Maxillary and mandibular made of plastic hinged Imported 93 Educational Model Class I Angle Class I Normal occlusion malocclusion Maxillary and mandibular made of plastic hinged Imported 94 Educational Model Class Angle ClassII occlusion division malocclusion Maxillary and mandibular made of plastic hinged Imported 95 Educational Model Class II Angle Class II Div2 occlusion division 2 malocclusion Maxillary and mandibular made of plastic hinged Imported 96 Educational Model Class Angle Class III Normal occlusion malocclusion Maxillary and mandibular made of plastic hinged Imported 97 Electrocautery Radiosurgical Unit should match the following Broad Specificat
38. for spectacles wearers ILLUMINATION SYSTEM Coaxial xenon illumination system180W xenon with backup 180W Xenon with quick action lamp changeover Illumination system should be integrated in the stand HANDGRIP Easily removable handgrips with adjustable keys for zoom and focus 33 Four freely programmable keys for setting illumination intensity controlling the integrated video camera FLOOR STAND Rollable floor stand on base with lockable castors column with height of 1 70 m carrier and swivel arms with large reach of 1 20 m Free float magnetic system Release of magnetic brakes by handgrips Liquid crystal display LCD with user prompts Quick set up amp Programming of different parameters and their activation at press of a button such as Zoom speed Focus Speed Starting illumination Starting working distance etc Automatic speed adjustment or automatic brightness setting depending on magnification brightness of video image magnetic brakes onff Suitable for connection to 230V 50 Hz single phase mains supply ACCESSORIES Angled optics with two side ports and rotatable adapter 22 5 degrees CCTV ATTACHMENT Advanced digital 3CCD video camera system with colour monitor STEREO CO OBSERVATION ATTACHMENT Stereo co observation device with three axis rotation straight binocular tube with focal length of 170 or 200mm and pair of high eye point wide field push in magnetic eyepieces
39. g screen for maximum clarity Visual amp sound alarms IPX1 level protection against liquids Uses AA size alkaline or rechargeable batteries Supplied with clip and case to attach to pillow Technical Specifications Patient Range Adult Pediatrics and neonatal patients Digital SpO2 Range 0 100 Resolution 1 Accuracy 70 to 100 2 Refreshing rate lt 13 seconds 37 Pitch Tone Yes Pulse Rate e Range 25 250 bpm e Resolution 1 bpm e Accuracy 2 or 1 bpm whichever is the greater e Refreshing rate lt 13 seconds DisplayT ype 2 4 color display 320 x 240 pixels Parameter Digital SpO2 Pulse Rate Pleth bar amp SpO2 waveform Alarm Audible alarm audible button tone Supports Pitch Tone and multi level volume Alarm tones meet the requirement of IEC 60601 1 8 Appearance Dimension 123mm H x 58 5mm W x 28mm D Weight lt 200g Data Storage Display Trend table Trend interval 2 seconds to 30 minutes Trend parameter PR SpO2 Trend data spot check mode ID from 1 to 99 300 records for each ID Battery Type 3 AA Alkaline batteries or NI MH rechargeable battery optional or Lithium ion rechargeable battery option Runtime 14 hours standard use Nellcor SpO2 probe compatible SAFETY STANDARDS e classification e Type of protection against electric shock II with internal power device e Degree of protection against electric shock CF e Degree of protection against ingress of liquid
40. her handpiece fully autoclavable with Autoclavable Nozzle 360 rotatable amp interchangeable nozzles amp Instruction Manual 137 IOPA X Ray Machine e It should be High frequency DC X Ray Wall mount e It should have smooth movement arm e It should have branded X Ray Tube Tube voltage should be 60 70 kvp variables Tube current should be 6 mA Exposure time should be 0 01 to 2 00 sec Focal spot should be 0 8x 8 mm It should have cone length of minimum 20 cm e Jt should have programmable time e It should have all international safety standards e It should be AERB Type Approved e It should be ISO certified and CE marked standardized 138 Ivory no 1 Retainers Matrix retainer no 1 Stainless steel Indian Make 35 139 Ivory no 8 Retainers Matrix retainer no 8 Stainless steel Indian Make 45 140 Jaquette sickle scaler Hu friedy Ash Equinox No 1 2 and 3 having medium sized blades 141 Kidney Trays Light weight Stainless steel make Large amp Medium size 150 142 Kirkland knife Hu friedy Ash Equinox double ended 143 Langman s Tissue retractors Stainless steel imported 29 144 Lathe AC HP 1 2 and RPM 2800 with 2 Ball bearings metal cable arm Machine should have low noise and high power the rotational speed should reach up to 14 000 rpm 145 Le cron carver
41. ient impression and finally mount the model e Ear piece amp bite forks should removable and autoclavable e It should have better access and visualisation of operating field 18 Autoclave Front loading e It should be fully Automatic front loading Autocalve e It should have 22 Lt Capacity with vacuum amp dry cycle e It should have universal class B cycle sterilizes wrapped unwrapped hollow or solid instruments e It should have Vacuums to 0 70 bar 3 Times during conditioning of the chamber for sterilization and vacuums to dryness of 0 2 humidity e It should have separate steam generation and chamber heating using steam boiler to generate steam and heating elements to heat up the chamber e Jt should give a better control over the steam generation and delivery thus reducing the amount of water used e It should have 3 instrument trays to hold different type of Instruments e It should have LED display of temperature time and pressure e It should have the pressure and temperature of the autoclave range from 15 PSI at 121 C to 30 PSI at 134 e It should have the body and trays of the autoclave made from corrosion resistant Stainless Steel e Jt should have Auto cut off amp stand by mode e It should have Safety thermostat to prevent overheating e should have Micro switch to confirm door closure e It should have 2 tanks for the storage of used and used water 13
42. ine Grade SS 50 Shallow type 250mmx150mmx40mm 242 Surgical Loupes Galilean It should have the widest field of 3 view and longest depth of focus e It should be excellent clear view and great optical capability to provide the operator with the optimal magnification while providing extended field of view e It should have a flip up facility e It should have a Magnification of 3 5 e It should have Working distance 420mm e It should have 90mm Depth of view e It should have 100mm Field of View e It should have Weight not more than 42 243 Surgical rectangular instruments SS make 35 tray with Lid e Length x width x height 350 x 250 x 50 approx 244 Surgical scissors Goldman fox scissor small in size 12 245 Surgical Suction Apparatus with e Silent 2 Surgical Nylon suction pipe e Vaccum 700 mm hg e Volume 25 30liter minute e Jars Graduated Glass wide mouth jar capacity 2 3 liter approx with synthetic rubber lids Body M S spot welded with SS top e Power 220 230 V 246 Suture cutting scissor Medium High quality steel sharp edges with fine tip 4 41 247 Suture cutting scissors small High quality steel sharp edges with fine tip 248 Table top water distiller e It should be economical cost saving production of 100 distilled pure water e It should have Automatic temperature thermostat control e should have automatically switches OFF when the proce
43. ing capacity hard and soft wire up to 1 5mm Imported 281 X ray clips For IOPA films stainless steel with 12 clips 282 X ray viewer LED Digital LED display high brightness of more than 4000lux light frequency above 50KHz Indian make for OPG films 283 X ray Film Dryer X ray film drying cabinet with standard ISI mark heating blower which is suitable for Intra oral radiographs hanger and X ray films of size8inches 10 inches 14 inches to 17 inches It should be corrosion resistant with slots for individual film hangers with capacity to accommodate at least 15 film hangers 284 X ray film processing tank Stainless steel electric manual processing insulated and anticorrosive tank for film sizes 4inch by 4 inch to 14 inch by 17 inch with master tan k with lid to accommodate tanks volume Of 9 1 for developer rinser and fixer with lid and running water of 13 5 ltrs with 45 automatic temperatutre control for developer rinser and fixer which is adjustable between 18degree and 28 degree centigrade Emptying system and drainage system for master tank and developer fixer and rinser tanks with stop cock Valve with overflow system with flexible tube connections and fuses 285 X ray film Holder High quality Plastic for bisecting angle technique Imported 286 X ray viewer LED Based Large size to enable viewing 4 CT MRI films together H
44. integrated temperature sensor for monitoring and compensating for shifts in room temperature The system should use to proven and approved Volumetric Metering system of cell counting for WBCs RBCs AND PLTs for high precision of the results and stability of the calibration The system should have a system of count and aperture monitoring every 0 5 secs for precision and reliability of the counts The system should have automatic floating thresholds for the correct separation of RBCs and PLTs during overlap in cases of Microcytes Large platelets System should not require any daily maintenance except daily shut down The system should automatically give an alarm to the operator for doing the maintenance The system should use of reagents only high intensity LED for Hb estimation reagents required should available locally from the company or its authorized distributor 5 Years comprehensive warranty Free installation at user site Standard accessories as per catalogue Suitable UPS FDS and CE certification Working manuals Should have authorized service centre in New Delhi Delhi Equipment should be complete in all aspects to start working from day one UPS minimum 30 minute back up should be provided along with the automated Biochemistry analyzer RO system of adequate capacity should be provided with Biochemistry autoanalyser Should have installation of the quoted instrument Model in
45. ion system for 4 onsite generation of non toxic disinfectant Wall Mounted e Generation System e The generator should be a compact system e Solution should be generated at low current of lt 10 amp e Mineralization of the generated solution should not exceed 5 gliter e ph of the generated disinfectant should be almost neutral e Power consumption should not be more than 400 watts e Should have capacity to produce 400L 21 of mixed Oxidant solution per day e The produced disinfectant solution should have oxidant concentration of more than 400ppm e System Operation Indicators like Power System Fuse and Error should be on the face of the equipment e The system should have a combined LCD Display for current amp voltage e The system should be automatic and should have provision for automatic generation of disinfectant as and when required e Should be supplied with a tank for storage of mixed oxidant system e The system should have large installed base More than 50 units in Indian hospitals e The installation should be completely automated with float sensor technology for the fluidics e Should run on specially prepared readymade electrolyte solution e Machine should be installable in the wall space area of 8 X 8 if one electric point and water point is provided along with a drainage outlet e Should be manufactured by WHO GMP GPP certified company e Water Treatme
46. ions e Unit should have cut coag and coag mode e Electrode rotable and autoclavable e Light and audio indication of the active mode for safety e Output power within 20 55 Watts range e Unit should be supplied with all standard accessories required operate with minimum 3 electrodes of different different applications shapes for e Unit should have minimum two years warranty Comprehensive e Alarm for improper connection e Normal Operating Frequency 3 5 to 4 MHz 23 should be 360 degrees e Coag Modulation Frequency 100 to 120 Hz e Output Impedance 500 to 600 Ohms e Weight not more than 4 Kg 98 Electronic weight balance Weighing range 0 1mg 100mg Sensitivity Img Electronically controlled digital monitor closed cabinet for electronic weighing 99 Electrosurgical cautery imported Automatic control output Five kind of working model Pure cutting blend Concreting fulgerize Bipolar Memory function with 10 memory places for different setting This ESU should give alarm when the patient plate does not connect properly The 1000KHz radio frequency frequency with coagulation and cutting modes different sound alarms for different working modes Bipolar with high efficiency smoke absorber 100 Enamel tray rectangular 15 inch stainless steel make Indian Make 35 101 Endodontic excavator Long shank excavator Light weight with d
47. it 6 powerful LED tubes which should emit a high intensive 17 Cold blue light It should oxidize 16 more teeth Should have atleast 5 time pre set programs and 3 different light intensity LCD screen to show all the information for better communication between the dentist and the patient 42 Bone file Hu friedy Ash Equinox double ended sugarman s and schluger type 43 Bone file 1X Miller Colburn Bone File 44 BP apparatus Digital monitor with strapped hand cuff to be used on the arm 45 BP Handle Suitable with 11 No BP blade High quality stainless steel Indian make 46 Bracket Holding Tweezer Curved For posterior teeth Specially suited for placing brackets and buccal tubes in the posterior area Stainless steel Imported 47 Bracket Holding Tweezer Straight With long placement and angulation aid For bracket placement The blade at the end of the tweezers can be used for angulating brackets Stainless steel Imported 48 Bracket Positioning Gauge Simplifies seating the brackets on the teeth in the correct distance between bracket slot and incisal edge With pencils Stainless steel Imported 49 Bur Chuck for lab lathe 50 Carborundum disc Ultra thin Indian 51 Cardio pulmonary resuscitation kit Airbag resuscitation bag 2 Face silicone masks 1 Pinocchio helicoidal mouth ope
48. ium sized 15 13 cm or less with locking system and small amp thin beaks 186 Needle Holder Mayos fine 5 Fully serrated jaw and 5 working length 3 Imported 187 NiTi chilling instrument Used with Heat Activated Wire fill with water 5 freeze and then used to chill the wire 188 Nola Dry Field System Saliva Totally dry field with absorbing pads and 2 Ejector Small amp Large cotton rolls System includes Cheek Retractor Silicone Tubing Connectors 189 Non lead apron with gloves and Indian make Light weight double sided large 2 thyroid shield size 5 25 mm lead 190 Operating Microscope MICROSCOPE BODY 1 Motorized zoom magnification system with apochromatic optics zoom magnification factors 0 4x 2 4x activation by handgrip and option of foot control panel Internal motorized fine focusing system activation by handgrip and foot control panel continuously adjustable working distance from 200 mm to 415 mm without exchange of objective lens manual override Integrated red free green filter and orange filter Integrated continuously variable illumination spot size 65mm to 11mm BINOCULAR TUBE 180 degree tiltable binocular tube with focal length of f 200 mm or more Graduated knob for continuous adjustment of inter pupillary distance from 55 mm to 80 mm EYEPIECES Pair of high eyepoint widefield push in magnetic eyepieces 12 5x Diopter setting from 8D to 5D Suitable
49. k technology without cooling fans Unit should have no tank reversal knob activated drainage system Unit should have 15 30 45 and 60 in tandom timer Noise level should not exceed 65 dB Unit should consist of the following Main accessories Main base unit fixed steel tank tank cover and power cable Extra long drain tube to dispose of contaminated used solution Cross flow 5 section finger guard instrument basket One accurate self measuring bottle of each solution Super concentrate general purpose cleaner Enzymatic Solution Germicidal Cleaner effective to kill HIV virus Cement remover solution Tank Capacity 14 litres to 15 litres Tank up capacity Min 75 of tank capacity 262 Ultrasonic scaler Imported amp portable peizo electric type With large capacity self Irrigation tank approx Capacity 300 400 ml compatible with commonly used chemical irrigants multiple power settings With tip changers Complete kit of scaling tips and subgingival inserts of all shapes amp sizes Frequency of 15 18 lacs cycle per minute Autoclavable tip holder Autoclavable box for tips Easy to clean Autoclavable Handpieces Foot control Esthetic and durable 11 263 Ultrasonic scaler with 3 functions of Scaling polishing and Endo Imported amp portable With large capacity self Irrigation tank approx Capacity 300 400 ml compatible with commonly us
50. kit Senn Green tracheal retractors Trousseau s tracheal dilator 5 14cm Chevalier Jackson s tracheal tubes with pilot one inner tube 16 to 34 french gauge 10 sizes normal radius Magill s catheter introducing forceps adult 10 25cm Child 8 20cm Senn Miller tracheal retractors double ended 256 Turbo Bite 5 pack of 100 For anterior teeth stainless steel modifications of incisor bracket placed lingually for bite opening 257 Turbo Bite 5 pack of 100 For posterior teeth stainless steel modifications bite blocks for anterior disocclusion 258 Turret Torque angle 5 and 7 5 grooves Angle 5 for 0 019 0 022 rectangular wire Angle 7 for 0 017 0 018 rectangular wire High quality stainless steel Precise slot size For forming 42 flat angled rectangular with torque Imported 259 Tweezer Durable stainless steel serrated tip Light weight Imported 900 260 Typodont with Metal and non metal teeth A compact fully functional articulator that allows the study of various jaw movements Teeth may be banded or bonded as desired Indian Make 261 Ultrasonic cleaner Tank should be made of high quality rust proof stainless steel Outer body should be made of High strength stain proof and scratch proof aesthetic plastic Unit should have load sensor for automatic power feeding Unit should have high quality heat sin
51. ly controlled unit for dispensing required quality of plaster at steady rate with On Off control switch Capacity 10kg wall mounted With International safety certifications 203 Plaster Mixing Spatula Metal with minimum 4 inches long wooden handle Straight 17 204 Plastic filling Instruments Durable stainless steel Light weight Imported 60 205 Pneumatic Crown puller Air activated and breaks cement seals using short repeated and low impact force It should be a hand held instrument that attaches to high low pressure air line connections Planmeca Similar 35 206 Polishing Compact Unit lathe Lathe with suction unit having Illuminated with with suction unit neon lamp Gates to close off the suction on the unused side 2 Safety screens transparent and adjustable Ergonomic store for instruments 207 Portable Conscious Sedation Standard Head Deminsions 9 75 24 8cm x Equipment 5 12 7cm x 12 5 31 8cm Floor model with five leg base e Mixed Gas Outlet Diameter 15mm ID 22m OD normal e Oxygen Inlet Male DISS CGA 1240 e Nitrous Oxide Inlet Male DISS CGA 1040 e Inlet Pressure Each Gas 50 55 psi e Oxygen Flow Range 3 10 lpm e Nitrous Oxide Flow Range 0 101 e With Safety features e N20 cut off in case failure of Oxygen supply e Low Pressure Oxygen Audible Alarm e Imported 208 Portable IOPA machine e Portable
52. mm amp Maximum Cutting Capacity archwires up to 016 x 025 Stainless steel Imported 154 Lingual Flush Cut Distal End Safety hold Cutter with TC tip To cut flush with the end of the buccal tube Minimum Cutting Capacity 012 30mm amp Maximum Cutting Capacity archwires up to 016 x 025 Stainless steel Imported 155 Lingual Micro Minature Ligature Cutter with T C tip Small narrow amp sharp pointed TC tips Maximum Cutting Capacity soft wire up to 012 30mm Stainless steel Imported 156 Lingual Mini Ligature Cutter 50 degree Angle Narrow tip is angled at 50 Maximum Cutting Capacity soft wire up to 012 30mm Stainless steel Imported 157 Lingual Mosquito Forceps Fine curved tips but strong enough for inserting archwires amp excellent for placing elastomerics to lingual brackets Stainless steel Imported 158 Lingual Reverse Keat Bondable Tube Holder Helps with accurate positioning of bondable tubes Stainless steel Imported 159 Lingual Stepped Archwire Plier For torquing amp bending both square amp rectangular wires Maximum Cutting Capacity wire up to 021 x 025 55mm x 64mm Stainless steel Imported 30 160 Lingual Weingart 60 degree Small serrated tapered tips are angled at 60 4 angle with Stainless steel Imported 161 Magnetic bur bo
53. nd 15 amplification littmann or similar 15 Water bath Double walled chamber has inner made of SS and 3 outer made of MS with powder coating A high speed stirrer with a motor of 1 20 H P Tem range 5 C above ambient to 100 C with accuracy of 0 5 48 ANNEXURE IV FORMAT PRICE BID SCHEDULE 1 Tender 2 Name of Supplier 3 Rates for items given as per technical specifications at Annexure III and adhering to the Format given below is a Pre requisite for considering quotations S Description of complete Unit Price Total Cost NO equipment with all accessories INR USD INR USD 1 Equipment Accessories Optional Upgrades Warranty Sales tax amp other taxes Excise duty if any Customs duty if any Packaging amp forwarding charges if any 6 For Octroi if applicable necessary certificate will be issued 7 Training cost if 8 Installation and commissioning cost if any 9 Any other charges if any 10 Grand Total in figures amp words Note Price must be quoted in US for imported equipments The validity of tender shall be 180 days after opening of financial bid 49 ANNEXURE V Self Declaration to be given by the bidder Tender s Reference No amp Date Tenderer s Name amp Address Person to be contacted Designation Telephone No Fax No Email The Registrar Jami
54. ner 1 Polycarbonate tongue forceps 3 Sterile guedel air ways small medium large 1 Oygen mask with anticrush tube 2 Endotrachael tubes cuffed of sizes 6 6 5 7 0 7 5 8 0 52 Cassette with intensifying screen Outstanding durability with aviation grade aluminum Cassette framework should be made to avoid damage from repeated handling Lightweight with strong corners locks and hinges made from the polymer and engineering plastics 5x7 inches 53 CBCT Imported 1 3D Modality with cephalometric module With preinstalled software for implants and surgery planning endondontics with cephalometric and orthodontic tracing and model analysis 2 01 Work station computers with the necessary configurations for the CBCT machine And reporting room 3 Server based software for unlimited 18 Clint viewing on open source platform Patient positioning standing Sensor type TFT Scan mode Continuous and pulse Scanning time 12 28 seconds Gray scale 14 bits Voxel size um 90 to 500 Field of view upto cm 5x5 8x8 10x5 10x10 17x6 17x11 17x13 5 Reconstruction time preferable 2 3 minutes Panoramic Modality Sensor technology TFT Exposure time 4 to 16 seconds Radiological exam options Panoramic segmented panoramic maxillary sinus LA TMJ x 2 LA TMJ x 4 Cephalometric Modality Sensor technology CCD Exposure time 0 1 to 3 2 seconds Radiological exam options Lateral frontal AP or
55. nical staff of Faculty of Dentistry has to be trained by OEM Registered Supplier or Distributor at their expense Eligibility Criteria The Bidder should be reputed company an authorized dealer distributor having after sales service agreement with the OEM Proof for the same to be enclosed alongwith address phone nos amp E mail etc of the Service Centre If ISO certified Company enclose documentary proof The bidder should have experience of more than five years in execution and maintenance of equipments quoted A certificate of establishment to be provided The successful bidder should enter into an Agreement with as per the contract form provided at Annexure VI If any article item is borne on the list of DGS amp D rate contract a copy of the RC be enclosed The tender complete in all respect along with tender fee and Earnest Money should reach the Faculty of Dentistry Jamia Millia Islamia Jamia Nagar New Delhi 110 025 on or before due date No tender after the last date shall be entertained Sequence of documents to be provided enclosed in each copy of the tender documents 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 Forwarding letter duly signed by the Authorized person Balance sheet with auditor s report for the years 2010 11 2011 12 amp 2012 13 Latest Income Tax Clearance Certificates Central Sales Tax VAT Sole Proprietary sole manufacturer certificate for proprietary item List
56. nt unit e Should be able to treat available potable water as per the Generator s requirement should be supplied with an inlet and outlet tank of 100 Liters each for storage 81 Distal End Cutter With longer handles for easier handling when shortening archwire ends Delicate design Wire holder Inserts made of hard metal Sharpening of inserts possible by the manufacturer Stainless steel with TC tip Imported 82 Dolphin Imaging System 11 5 Fully loaded 2D 3D imaging software with ceph tracing analysis Morphing treatment simulation superimposition enhancement 83 Dontrix Gauge Dynamometer For measuring the force of elastics or springs upto 200gm Imported 84 Double beak plier anterior With beaks for anterior band forming Can be used on both sides Stainless steel imported 85 Double beak plier posterior With concave beaks For forming bicuspid and molar bands in the mouth Can be used on both sides Stainless steel imported 86 Double Ended lathe Trimmer With wheel Indian Indian unident confident similar 87 Dry Heat Sterilizer Rapid sterilization with operating cycle of 6 min 8 min amp 12 min Temperature range 320 360 degrees celcius 2 instrument trays Should not rust corrode instruments 22 88 Educational Model with Ceramic Brackets Angle Class I Normal occlusion Roth 22 Fitted with ceramic brack
57. ntee JMI shall forfeit Bank Guarantee in the event of a breach of contract by the successful supplier 3 A proposal would be rejected for award if it determines that the bidder recommended for award has directly or through an agent engaged in corrupt fraudulent collusive or coercive practices in competing for the contract in question 4 The tenders received after the deadline for submission of bids prescribed by the Purchaser will be rejected and such tenders shall be marked as late and not considered for further evaluation 5 The JMI may at its discretion extend the deadline for submission of bids by amending the bid documents in accordance with clause relating to Amendment of Bidding documents in which case all rights and obligations of the JMI and Bidders previously subject to the deadline will thereafter be subject to the deadline as extended 6 The original and all copies of the bid shall be typed or written in indelible ink and shall be signed by the bidder or a person or persons duly authorized to bind the bidder to the Contract All pages of the bid except for un amended printed literature shall be initialed by the person or persons signing the bid Further over writings on documents if any should be supported by signatures 7 The bidders may submit their duly sealed Tender by post or by hand at the address specified in the Notice Inviting Bids not later than the time and date specified therein In the event of the specifie
58. of Similar equipments supplied by the firm with addresses and phone numbers of customers with satisfactory completion certificate satisfactory working certificates Name and address of registered office Head Office and Regional office of the company with name and phone numbers of key persons List of deviations from the tender specification duly signed page wise Commercial terms and conditions with time schedule for completion 10 Proof of the authorized agent distributors dealer 11 Acceptance of all clauses of tender specification duly signed page wise Signature of authorized person Name Seal with contact details of firms and person ANNEXURE I Conditions of Contract Terms amp Conditions 1 The tenderer shall be required to deposit 3 Earnest Money of estimated value of goods to be procured through Bank Draft Fixed Deposit Receipt Bank Guarantee drawn in favour of The Registrar Jamia Millia Islamia No tender shall be accepted without the Earnest Money and Tender Fee The JMI shall forfeit EMD if the sueecessful tenderer fails to furnish the required Bank Guarantee 2 The successful supplier will submit a Bank Guarantee equivalent to 5 of the total value of purchase order at the time of installation which would remain valid for a period of 60 days beyond the date of completion of all obligations of the supplier including warranty obligation EMD will be released to successful bidder after submission of Bank Guara
59. of opening of the financial bids No change in prices and change in terms and conditions will be permitted All quoted items must carry brochure catalogue Pamphlets Technical Literature and related documents The supplier further warrants that the goods shall be free from defects arising from any act or omission of the supplier or arising from design materials and workmanship under normal use in the conditions prevailing in India The Technical Bids will be opened at the first instance and evaluated by a Competent Committee or Authority At the second stage Financial Bids of only the technically acceptable offers will be opened for further evaluation and ranking before awarding the contract Imported items should be the items imported from any country except China Therefore bidders should not quote the price of Chinese products and should mention explicitly the origin of the manufacture of the items to avoid rejection of bid Installation testing commissioning of the equipments should have to be carried out by Technical experts of the company supplier up to the satisfaction of user department of JMI 20 21 22 23 24 25 26 27 28 29 30 31 The suppliers will undertake warranty of equipment instruments from the date of installation and shall have to mention clearly the period of warranty in financial bid In case replacement of a part becomes necessary during warranty period the parts of the s
60. on with stainless air nozzles e Option of Hand and Footwear Disinfection System based on the process of vaporization cum nebulization e Double sided version must be quoted suitable for site e Option for single leaf and double leaf version must be quoted suitable for site e Chamber based sufficient for one surgeon at an instance 5 Airotor handpiece Push button type W amp H NSK similar 25 6 Alginate Mixing Spatula Plastic straight Handle size minimum 4 31 inches Indian 7 Alginator mechanical mixer Fixed rubber bowl motorized with 2 speeds 2 including reverse 220v AC Imported 8 Amalgam Carver Diamond shape Durable stainless steel Light 165 weight Imported 9 Amalgam Condenser Round shape Durable stainless steel Light 165 weight Imported 10 Amalgamator e alloy amalgamator 3 e Programmable for timing and quantity of mix e Reserve for amalgam alloy and mercury e 220 volt supply 11 Apex locator e It should Locate and calibrate Apex 4 Automatically e It should be able to measures root canal length in dry and wet conditions e It should have Audible signal and meter for indicating the position of the apical constriction and file distance from apex e It should work multi frequency measuring software technology e It should have a canal length indicator bars sound volume control off low high e It should contain large LCD display with informa
61. or with attachments e With Control box 2 e With Foot pedal e With Contraangle Micromotor Handpiece NSK Similar e Marathon Similar micromotor 169 Mini Implant Educational Model Clear soft model with two Mini implants 1 placed 170 Model Arch Trimmer with Large stainless steel work surface with 1 Carbide Burs generous venting for dust removal 1 1 2 38mm hose connection connects directly to 1 1 2 vacuum hose 171 Model Boxes Set of 10 Plastic in different sizes for orthodontic 200 models 172 Models for teaching Showing various gingival periodontal 2 diseases 173 Models for teaching Showing caries and trauma 2 174 Module Placing Plier Curved For tying stainless steel ligature or elastics 5 interdentally Stainless steel Imported 175 Module Placing Plier Straight For tying stainless steel ligature or elastics 5 interdentally Stainless steel Imported 31 176 Moons probe Stainless steel double ended Imported 60 177 Mosquito Forceps straight Fully serrated jaw and 5 working length the narrow pointed straight Stainless steel Imported 178 Mosquito forceps Curved Fully serrated jaw and 5 working length the narrow pointed curved Stainless steel Imported 179 Motorised Dental Chair Unit with Attachments The chair should have extra wide back rest and seat with seamless upholstery for total patient comfort It should have movable
62. pair shoes and with warning light ultraviolet radiation switch sterilizing light count righting switch counting monitor and a power switch 22 Automatic Tooth Shade Spectrophotometer based CIEL a b based Matching device shade selection include optional determination of VITABLOCS shades analysis of enamel individual teeth or teeth areas restoration mode shade specification using VITA SYSTEM 3D MASTER and VITA classical 1 04 sophisticated communication software as well as a memory upgrade from 25 to 30 measurements Automatic amp Manual Calibration system LCD display with menu system based software Should have a training mode and Ceramic Restoration verification mode Hand held cordless with Li ion rechargeable battery total weight not more than 550gm Warranty 3 years 14 23 B P Handle No 3 amp 4 High quality steel sterilised Indian Per Each 17 24 Ball Burnisher Round shape Durable stainless steel Light weight Imported 125 25 Band Seater Light weight Stainless steel sterilizable With large surface tin inlay imported 26 Band benching peek Hammer Head plier For bending nickel titanium arches wires in the molar region The two ends fit together like a tongue and groove around the nickel titanium wire so that the ends of the wire attain the required bend with one squeeze of the pliers max wire thickness 0 45 mm 18 F 0 41
63. payment on account of purchase Free training shall be imparted to faculty technical staff for operation maintenance and troubleshooting at the user department of JMI The bidder may submit the proprietary certificate for the item s if applicable In a tender either the Indian agent on behalf of the Principal OEM or Principal OEM itself can bid but both cannot bid simultaneously for the same item product in the same tender If an agent submits bid on behalf of the Principal OEM the same agent shall not submit a bid on behalf of another Principal OEM in the same tender for the same product 32 33 34 35 36 37 38 JMI shall consider any suggestion of bidder s for any change amendment in specification or any clause of tender document within 15 days of notifying the NIT No request for change amendment in specifications or any clause s of tender will be accepted afterwards All corrigenda will only be notified on the JMI website Jamia Millia Islamia reserves the right to purchase varying quantity of material less or more In the process of evaluation comparison of bids Jamia Millia Islamia reserves the right to reject any or all tenders Issuance of tender documents should not automatically be construed that the bidder is considered qualified The JMI Authority have the right to reject any bids on technical commercial grounds without assigning any reason Jamia Millia Islamia shall not be responsible for
64. pply of those equipment instrument and after sales services for sum of Contract Price in Words and Figures hereinafter called the Contract Price NOW THIS AGREEMENT WITNESSETH AS FOLLOWS 1 In this Agreement words and expressions shall have the same meanings as are respectively assigned to them in the Conditions of Contract referred to 2 In consideration of the payments to be made by the JMI to the Supplier as hereinafter mentioned the Supplier hereby covenants with the JMI to provide the equipment instrument and after sales services and to remedy defects therein in conformity with the provisions of the Contract in all respects 3 The JMI hereby covenants to pay the Supplier in consideration of the supply of the equipment instrument and after sales services and the remedying of defects therein the Contract Price or such other sum as may become payable under the provisions of the Contract at the times and in the manner prescribed by the Contract 51 Brief particulars of the equipment instrument and after sales services which shall be supplied provided by the Supplier are as under SL BRIEF DESCRIPTION QUANTITY UNIT TOTAL DELIVERY OF EQUIPMENT TO BE PRICE PRICE TERMS NO INSTRUMENT AND SUPPLIED AFTER SALES SERVICES TOTAL VALUE DELIVERY SCHEDULE SIGNATURE OF AUTHORISED SIGNATORY Name Designation Name of the firm Seal REGISTAR JMI NAME
65. s The Faculty of Dentistry Jamia Millia Islamia has the requirement of equipments instruments The interested bidders are required to submit their bids in two parts 1 Technical Bid 3 copies with first copy in original with Tender fee amp EMD should be sealed in separate envelopes duly superscribed Technical Bid _ TENDER NO 02 FOD EQPT JMI 2013 14 for Faculty of Dentistry 2 Financial Bid 3 copies with first copy in original should be sealed in a separate envelope duly superscribed Financial TENDER NO 02 FOD EQPT JMI 2013 14 for Faculty of Dentistry Both Technical and Financial Bids sealed envelopes covers are to be put in a bigger cover envelope which should also be sealed and duly superscribed as Tender No 02 RO PICO FOD JMI 2013 14 Equipments Instruments for Faculty of Dentistry addressed to The Dean Faculty of Dentistry Jamia Millia Islamia Jamia Nagar New Delhi 110025 Activity Date Time Venue Last date for submission of 22 5 2013 01 00 Faculty of Dentistry JMI Tender p m New Delhi Opening of Technical Bid 23 05 2013 3 30pm Faculty of Dentistry JMI Opening of Financial Bid Shall be intimated to technically qualified supplier by email and phone Place of Work Work to be rendered by the company s under this tender is to supply installation and commissioning of the equipments instruments in the Faculty of Dentistry JMI The faculty tech
66. ss is finished e It should be Easy to operate and easy to clean e It should have tank capacity not less than 4 liter 249 Three Plane Articulators 3 5 disk type Indian Make 250 Three prong pliers For bending wires arches for the fixed appliance technique Specially suited for bending NiTi wires arches such as rematitan LITE and Tensic max wire thickness 0 5 mm hard F 0 48 x 0 64 mm 19 x 25 Stainless steel Imported 251 Tissue forcep Hu friedy Ash Equinox small working head toothed and without tooth 252 Tofflemire retainers Matrix retainer for tofflemire band stainless steel Imported 50 253 Top Loading Autoclave Triple walled construction all the three walls made of thick high grade stainless steel sheet of SS 304 grade The lid should be made of stainless steel sheet The unit should be fitted with radial locking system with paddle lifting device made of MS chrome plated Should be provided with built in safety valve pressure gauge pressure release valve and water level indicator The pressure should be adjustable from 5 psi to 20 psi with automatic pressure control switch which controls the pressure with an accuracy of 1 psi Working Pressure Variable from 5 psi to 20 psi Working Temperature 121 C 98 Liters 254 Torquing Key For placing the torque in the arch wire Stainless steel Imported 255 Tracheostomy
67. t dissolve in poly acrylic acid Imported 70 Air Sterilizer amp Asepticization System Room e The system should be based on ultraviolet radiations with controlled wavelength to block the microorganisms reproductive capacity by altering their chromosomes e The wavelength should be 253 7 nanometers to get powerful germicide power enough to destroy the most resistant microorganisms including Anthrax e system should reduce microbial load present in the air inside by irradiation continuously even in the presence of staff operators without generating any health risks e system should have validation certification of being tested recognized agencies for compliance with international standards for air sterilization Air capacity 25 m hour level 23000 e Power absorption 100 W e High velocity HEPA filtered air jets with velocities of more than 20 m s ensuring efficient action to remove particulate matter at the entrance area e Mini pleated HEPA filtration to achieve more than 99 99 efficiency at 0 3 micron particles e A disposable pre filter with 85 to 90 arrestance e emergency stop button is mounted on both sides of the shower e Indicators light mounted on both sides of the air 11 shower exterior regulate traffic flow in and out of the clean room e Permanently lubricated direct drive centrifugal blower are used in conjuncti
68. tion display canal length indicator bars sound volume off low high battery power indicator meter bar for the ratio technique adjustable apical line e Rating DC 4 5 V Power Consumption 0 135 VA e should have weight not more than 200 grm e It should contain all accessories ie 1 probe cord 3 file holders 3 lip hook 1 canal length tester 1 extension cord 4 1 5 V AAA battery 12 Arch wire stand For storing and easy dispensing of preformed 6 archwires Should hold up to 10 wires at a time with cover Imported 13 Artery forceps curved Medium for holding ligature wires in posterior 67 region Stainless steel Imported 12 14 Artery Forceps straight Medium for holding ligature wires in anterior region Stainless steel Imported 44 15 Articulating jig For forming bases on the study models for orthodontic purpose It should have 2 hard bases in aluminium 2 silicon bases 2 reference pins of stainless steel 1 transparent axis plane and one front planarity pin Imported 16 Articulating paper holder Henry Schein similar Stainless Steel 19 17 Articulator with Facebow Hanau H2 artex similer Facia Facebow with Earpiece amp Bite fork e It should be semi adjustable easy to operate e It should be ideal for prosthetic laboratory procedures e It should be with important tools for diagnosis and treatment planning e It should be easy to make pat
69. urable steel tip Imported 25 102 Endodontic Explorer Long blade Durable stainless steel Light weight Imported 103 Endodontic plugger Heat carrier plugger with handle Double ended size 20 30 35 Light weight with durable steel tip Imported 12 104 Endodontics photo activated disinfection System Wave length 633nm with LED technology Should be using with medical grade Tolunium chloride 60 sec contact time with Tolunium chloride solution 60 120 sec light activation time Small and compact size for the chair side unit Built in programs for Endo caries perio and other dental applications 105 Endomotor with reciprocating function Endo motor with 1 6 Hand Piece Battery powered 2000 mAh 6V TORQUE VARIATION 0 2 4 0 Ncm in continuous rotation Speed 1500 6000 rpm in continuous rotation Operating Mode Continuous Rotary and Reciprocation At least 12 programs 106 Exacto bite Compatible with either wax or silicone bite registration materials Blue 2mm amp White 4mm 107 Extraction forceps Light weight with durable steel tip Set of 8 foreceps imported 108 Film Duplicator e Accommodates 5 x 7 5 x 12 and 6 x 12 films e Power Supply 110v 220v duplicator for intraoral extra oral films Imported e Completed Exposure to be indicated e Constructed of steel finished in durable baked enamel e Can
70. x 0 56 mm 16 x 22 Stainless steel imported 27 Band Contouring plier Curvature of the beaks only on one side For contouring and adapting bands Light weight Stainless steel imported 28 Band cutting scissors curved For cutting thin metal orthodontic bands Stainless steel Imported 29 Band cutting scissors straight For cutting thin orthodontic metal band material Stainless steel Imported 30 Banding plier Tweed ribbon arch For applying torque to edgewise wires Parallel grip prevents crushing of wire Inserts made of hard metal max wire thickness F 0 56 x 0 70 mm 22 x 28 Stainless steel Imported 31 Banding Plier De La Rosa With guiding grooves for forming round and square arches 16 18 22 Stainless steel imported 32 Banding pliers Lingual Technique For bending in increments and to compensate curves in arch wire for the lingual technique Increments 1 5 2 0 2 5 and 3 0 mm max wire thickness 0 5 mm hard Stainless steel imported 33 Band pusher With serrated rectangular tip and anatomically formed grip for good transfer of force when positioning bands Light weight Stainless steel imported 34 Band removing plier Anterior Long chisel tip with carbide insert Facilitates removal of anterior bands With replaceable occlusal nylon pads For removing anterior bands Stainless steel With replaceable plastic tip With replacea
71. x Autoclavable under the high temperature of 28 135C and pressure of 0 22Mpa Imported 162 Mallet Surgical mattet medium size Imported 3 163 Marquis colour coded probe Hu friedy Ash 2 164 MBT Gauge Imported precision machine handles colour 2 coded size establishes proper bracket height measured from bracket slot to incisal occlusal surface of tooth 165 Micro implant Kit Micro Implants Long hand Driver Short Hand 2 Driver Hand Contra Angle Driver Pilot Drill Engine Driver Driver Tips Imported 166 Micromotor handpiece e Micromotor Handpiece speed should be 2 22 000 to 27 000 RPM Contra Angle e Compatible with Marathon Micromotor e NSK Similar 167 Micromotor heavy duty Lab It should be brushless DC motor 1 Duty It should have Speed range of 1 000 50 000 rpm It should have High Torque of up to 7 N cm It should be light wt not more than 220g It should provide optimal power for all types of crown bridge and acrylic work It should have min noise and vibration It should have convenient compact size permits fatigue free working even over many hours It should have ultra slim and ultra light hand piece cable to give the user additional freedom of movement It should have Dust tight ball bearings for dirt free amp longevetiy of bearing It should have Ergonomic design for Fatigue free work It should have aving overload protection with quick diagnosis LED With International safety certifications 168 Micromot