Home
Product Manual SW5
Contents
1. Flocculator SW5 Instructions for use lt E gt Bibby Scientific Pre set selector Speed control Display Mains on off Lamp on off Press to set AS stirring lamp mains at 52 Fig 2 Control panel Thank you for purchasing this Bibby Scientific product To get the best performance from the equipment and for your personal safety please read these instructions carefully before use This equipment is designed to operate under the following conditions For indoor use only Use in a well ventilated area lt Ambient temperature range 5 C to 40 C Altitude to 2000m Relative humidity not exceeding 80 Mains supply fluctuations not exceeding 10 Overvoltage category Il IEC60364 4 443 Pollution degree 2 IEC664 If the equipment is not used in the manner described in this manual the protection provided by the equipment may be impaired Electrical Installation THIS EQUIPMENT MUST BE EARTHED Before connection please ensure that the line supply corresponds to that stated on the rating label This unit requires a supply rated at 230V 50 60Hz single phase Power consumption is 100W There is an IEC socket at the rear of the instrument for connection to the mains supply The unit is supplied with two mains leads fitted with IEC plugs for connection to the instrument One has a U K 3 pin plug and the other has a 2 pin Shuko plug for
2. a possibility that injury damage or loss might occur if equipment malfunctions due to radio frequency interference or for general advice before use please contact the Service Department of Bibby Scientific Ltd Declaration of Conformity Flocculator Model SW5 These products comply with the requirements of the EU Directives listed below 2004 108 EC EMC Directive 2006 95 EC Low voltage Directive LVD Compliance with the requirements of these Directives is claimed by meeting the following standards EN 61326 1997 Amendments A1 1998 EN 61000 4 2 1995 EN 61000 4 4 1995 EN 61000 4 5 1995 EN 61000 4 6 1996 EN 61000 4 9 1993 EN 61000 4 11 1994 EN 61000 3 2 1995 EN 61000 3 3 1995 EN 61010 1 1993 Amendments A1 1992 amp A2 1995 EN 61010 2 51 1995 Compliance Certificates and Full Reports Ref RETSO287 51 and RETSO287 52 The above certificates and reports from Epsilon Technical Services an independent test house are available upon request CE mark affixed 02 Signed Date To loa Authority Technical Development Manager Bibby Scientific Ltd Mr D E Hicks CEng MIEE Bibby Scientific Bibby Scientific Ltd Stone Staffs ST15 OSA UK Tel 44 0 1785 812121 Fax 44 0 1785 813748 DofC_88_Rev01 INSPECTION REPORT MODEL SW5 ELECTRICAL SAFETY 1 Earth continuity 2 Insulation 3 Flash test FUNCTIONAL 1 Indicators 2 Speed 3 Visual accept
3. ance QUALITY CONTROL INSPECTOR SSD SSD Bibby Scientific France SAS ZI du Rocher Vert BP 79 77793 Nemours Cedex France Tel 33 1 64 45 13 13 Fax 33 1 64 45 13 00 e mail bsf bibby scientific fr www bibby scientific com Bibby Scientific Bibby Scientific Ltd Beacon Road Stone Staffordshire ST15 OSA United Kingdom Tel 44 0 1785 812121 Fax 44 0 1785 813748 e mail info bibby scientific com www bibby scientific com Bibby Scientific US Ltd 3 Terri Lane Suite 10 Burlington NJ 08016 USA Tel 800 225 9243 Fax 609 589 2571 www bibby scientific com Bibby Scientific Italia Srl Via Alcide de Gasperi 56 20077 Riozzo di Cerro al Lambro Milano Italia Tel 39 0 2 98230679 Fax 39 0 2 98230211 e mail marketing bibby scientific it www bibby scientific it Bibby Scientific Asia Ltd Room 607 Yen Sheng Centre 64 Hoi Yuen Road Kwun Tong Kowloon Hong Kong Tel 852 3583 1581 Fax 852 3583 1580 e mail bibby bibby scientificasia com www bibby scientificasia com
4. connection to the mains supply Choose the lead appropriate for your electrical installation and discard the other Should neither lead be suitable take the lead with the U K plug and replace the plug with a suitable alternative See the enclosed instruction sheet for advice on how to carry out this procedure Should the mains lead require replacement a cable of 1mm of harmonised code HOSW F connected to an IEC 320 plug should be used N B The UK mains lead is protected by a 10A fuse mounted in the plug top The mains lead should be connected to the instrument BEFORE connection to the mains supply IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN Safety Advice Before Use Never move or carry the unit when in use or connected to the mains electricity supply Never move or carry the unit while beakers are in place The SW5 may be carried by the handle on the top of the unit General Description The Stuart SW5 Flocculator is designed to ensure repeatable conditions between samples during water and sewage flocculation tests The speed control has electronic feedback to accurately maintain the rotational speed of the stainless steel paddles A digital display clearly indicates the speed which is variable between 25 and 250 rpm Alternatively the use of two adjustable pre sets allows repetition of pre selected speeds at the flick of a switch All paddles can be easily lifted out of the samples when required Ob
5. on the digital display Selecting a pre set speed Set the Pre set Selector to the P1 position To change the fixed speed insert the blade of a small screwdriver and turn the screw control clockwise or anticlockwise until the desired speed in rpm appears on the digital display Now every time the Pre set Selector is put to the P1 position the stirring paddles will rotate at that speed If a second pre set speed is required set the Pre set Selector to the P2 position and repeat the procedure Maintenance amp Servicing WARNING Ensure the unit is disconnected from the mains electricity supply before attempting maintenance or servicing Periodically clean the instrument using a damp cloth and mild detergent solution Do not use harsh or abrasive cleaning agents Any repairs or replacement of parts MUST be undertaken by suitably qualified personnel The following spares and accessories are available from your laboratory dealer Description Catalogue Number Fuse ESM3C15 S UL Mains On Off ESM3C21 S Paddle CSW124 Light tube ESW501 S Motor MSW501 S For a comprehensive list of parts required by service engineers conducting internal repairs and a service manual please contact the Service Department at Bibby Scientific Ltd quoting both the model and serial number Only spare parts supplied or specified by Bibby Scientific Ltd or its agents should be used Fitting of non approved parts may affect the performance and safe
6. servation and monitoring of samples is assisted by diffused base illumination and a black background Controls see previous page Figure 2 shows the controls for the SWS Mains on off This is a rocker type switch which illuminates when the unit is on Lamp on off This is a rocker type switch which illuminates when the unit is on Pre set selector This three way switch allows selection of either variable speed VAR or one of the two pre set speeds P1 and P2 Speed controller This knob controls the paddle speed in conjunction with the press to set switch Turning it to the right increases the speed turning it to the left decreases the speed Digital display This screen displays the paddle speed in rpm Operation see Fig 1 amp 2 Place the unit on a firm level surface and connect to the mains supply Leave sufficient space to access the side IEC socket Turn the mains and lamp switch on and observe the fluorescent lamp illuminate Use the blue knob to move the stirrer paddles up or down as required To position a beaker lift the paddle up to its maximum height using the paddle lift and place the vessel over the illuminated base Once the samples are in position lower the paddles into the beakers to the required depth Selecting a variable speed Set the Pre set Selector to the VAR variable position Hold down the Press to set switch and turn the Speed Controller until the desired speed in rpm appears
7. ty features designed into the instrument If in any doubt please contact the Service Department of Bibby Scientific Ltd or the point of sale Warranty Bibby Scientific Ltd warrants this instrument to be free from defects in material and workmanship when used under normal laboratory conditions for a period of three 3 years In the event of a justified claim Bibby Scientific Ltd will replace any defective component or replace the unit free of charge This warranty does NOT apply if damage is caused by fire accident misuse neglect incorrect adjustment or repair damage caused by installation adaptation modification fitting of non approved parts or repair by unauthorized personnel Bibby Scientific Ltd Beacon Road Stone Staffordshire ST15 OSA United Kingdom Tel 44 0 1785 812121 Fax 44 0 1785 813748 e mail info bibby scientific com www bibby scientific com Technical Specification SW5 No of samples 2 Speed range 25 250rpm Speed pre sets 2 Speed display LED Dimensions 320 x 210 x 500mm Net weight 8 6kg Power 100W Notes These products meet the relevant EC harmonised standards for radio frequency interference and may be expected not to interfere with or be affected by other equipment with similar qualifications We cannot be sure that other equipment used in their vicinity will meet these standards and we cannot guarantee that interference will not occur in practice Where there is
Download Pdf Manuals
Related Search
Related Contents
Copyright © All rights reserved.
Failed to retrieve file