        Kilotech weighing scale KWS
         Contents
1.                     ASCII   LCD LED Show    Asci    LCD LED Show    ASCII   LCD LED Show   1 l B H 0     2 d C H p H  3 4 D Fa Q z  4 U E E R r  5 b F E S L  6 b G g T L  HN leg  s H   i    U   gt   B 3  d w   0   K H x H   L         d   M h z 4   Kilotech Inc USA 877 328 5988 CANADA 800 694 4445    23    16  Packing List    KWS VS2000 Operation  amp  Service Manual                                                          No  CONTENT QTY  1 Indicator 1  2 User manual 1  3 Swivel bracket 1  4 AC Adapter 1  5 RS232 cable Optional  6 USB interface Optional  7 USB cable Optional  8 Bluetooth Module Optional  9 1x CR2032 battery for RTC Optional  10 4xAA Alkaline batteries Optional  11 4xAA NIMH batteries package optional   16  Version History  VERSION DESCRIPTION DATE  V1 0 Initial version 2011 09 21                         Kilotech Inc USA 877 328 5988 CANADA 800 694 4445 24          
2.      SYMPTOM PROBABLE CAUSE REMEDY  Ad Load cell wires to indicator are   Make sure wires are ok and correctly  incorrectly connected  or shorted  or   connected  Replace load cell or ADC  Ad    opened  or ADC  load cell are damaged   chip  Service required   pom Weight reading exceeds Power On Zero   Make sure scale platform is empty   limit  Perform zero calibration     Weight reading below Power On Zero Install platform on scale  Perform  X TOYS  limit  zero calibration             Reduce load on scale until weight  Weight reading exceeds Overload limit   f value can be displayed  Use a more  Mei or The weight value cannot be displayed   l          appropriate unit of measure  Re set  in the current unit of measure because it  ns some parameters of CONFIG or  exceeds 6 digits    UAER   T Install platform on scale   MOON Weight reading below Under load limit  E  Perform zero calibration  Hepes CONFIG or CAL parameters are not Re set items in CONFIG  do    correctly set calibration  EEP E2 USER parameter is not correctly set Re set items in USER  Set PRIM N PRIM d SECND n to  CAP ER Capacity parameters are not correct correct number  make sure capacity  not more than 6 digit  Calibration error  maybe input data or Input correct data  load correct  CAL Er loaded weight is too small  too big  weight onto platform  Service  unstable  un linear required  Piece weight is error  it   s too small    lt 0 5d   The weight on the platform is    PWT ER   S Use a greater weight for the 
3.   Weighing Counting Percent    T  Output data to serial communication port  press down   3s    PRINT   Weighing Counting Percent      select working mode  weighing  counting or percent  FUNC press down  gt  3s c S S       T Input data mode The digit on flashed position add 1       Menu selection mode To last item of current menu    Weighing Counting Percent  To add up current weight pieces percentage to memory   press down   3s display times and total of accumulation   ACC   TOTAL    Weighing Counting Percent  f f l  To display times and total of accumulation  press down  gt 3s    Input data mode the digit on flashed position subtract 1       Menu selection mode To Next item of current menu    ma Change weighing units  kg  gt lb  gt lb oz  not be available in  Weighing mode  press down  3s n  some conditions   gt kg  Counting Percent mode  To enter getting piece weight or unit percentage weight  press down    3s mode  by way of sample or input directly    Weighing  Counting Percent mode  To input compare data  for weight   pieces or percentage    press down   3s of high and low limitation       UINT Display date or time mode   DATA To set current date or time  press down  gt 3s              Display voltage mode   To calibrate input voltage value    Select displaying code from no filter  filter1  filter2          Rotate the flashed position from left to right       Kilotech Inc USA 877 328 5988 CANADA 800 694 4445 8    KWS VS2000 Operation  amp  Service Manual    Weighing Coun
4.   number and press TARE key to confirm  Announciator of Hi will be shown in this step  Press ZERO key  to exit and back to weighing mode    4 13 4 After Low being shown  000000 will be displayed  use PRINT  ACC  UNIT key to input low weight   number and press TARE key to confirm  Announciator of Lo will be shown in this step  Press ZERO key  to exit and back to weighing mode     NOTE  If High number is 0 or is equal or less than low number  the comparison will be disabled  and the  input data has no limitation     4 13 5 After a reasonable limitation is set and compare is be active  one of announciators HI  OK  LO will be  lighted  and the beeper will sound according to its setting in USER BEEP     4 14 Enter Setup Mode    4 14 1 If need to set configuration parameters  set user parameters  calibrate the scale  set current date or  time  test some hardware    It   s need to long press SETUP key to enter setup mode   4 14 2 After Entering Setup Mode  the main menu item CONFIG will be shown first    4 14 3 In Setup mode  use 4 _ T l  j ge  L   to select wanted submenu and wanted  menu item  select wanted choice  set wanted number  confirm and save data  or exit this mode  Please  refer the    4 Operation Menu Structure        5  Count Weighing Mode    5 1 In this mode  scale will weigh goods weight on scale  calculate and display its counts after the piece  weight of goods is obtained   5 2 To make counting function be available  CONFIG FUNC COUNT item should be set to YES in C
5.  2 Provides smooth curve fit through four points   1 11 3 Calibration can be done under kg or Ib weight unit with 10   100 FS standard weight  1 11 4 Directly weight fine adjustment    10      1 12 Real Clock  optional built in nonvolatile real time  amp  date    1 13 Other Main Function   1 13 1 Programmable Zero Range  1 13 2 Programmable pre set tare weight   13 3 Programmable automatic zero point tracking   13 4 Programmable motion detection window    1  1   1 18 5 Programmable auto power off time  backlight working mode   1 13 6 Programmable hold function  with peak weight holding   dynamic weighing  1 13 7 Available Check Weighing Mode   1     13 8 Available Parts Counting Mode  1 13 9 Available Percentage Working Mode  1 13 10 Available Measure Unit  kg  Ib  Ib oz  PCS  95   1 13 11 Data Comparison and indicator of High  OK and Low is available in Weighing mode  Parts Counting  mode and Percentage Working mode     1 13 12 Battery voltage display and charge indicator  1 13 13 Programmable serial output content    Kilotech Inc USA 877 328 5988 CANADA 800 694 4445 6    KWS VS2000 Operation  amp  Service Manual    2  Faceplate    jl               s       N        v  I  I    S                   EE  EE       d  of symbol on faceplate     2 1    2290       2 3 NET       2 4 TOTAL  2 5 Ib  26 oz  2 7 kg  2 8    2 9 Pcs  2 10 BMI  2 11 PEAK  2 12 HOLD  2 13 HI    2 14 OK    2 15 LO    2 16 Bw    turn on when scale is stable   turn on when scale is at zero point and the gross we
6.  Manual    Thank you for purchasing the KWS V2000 indicator  Please read all operating instructions carefully  before use and keep the following points in mind       Avoid lengthy exposure to extreme heat or cold  your scale works best when operated at normal room  temperature  Always allow the scale to acclimate to a normal room temperature before use      Allow sufficient warm up time  Turn the scale on and wait for a few minutes if possible  to give the internal  components a chance to stabilize before weighing       These electronic scales are precision instruments  Do not operate near an in use cell phone  radio  computer  or other electronic device  These devices emit RF and can cause unstable scale readings  If your scale ever  performs poorly  try moving the scale to a different room or location      Avoid using in condition of heavy vibration and airflow       Read the weight reading in short time after loading  The output signature of load cell and electronic circuit  may be little influenced after weighing for a long time     1  Specification    1 1 Housing and Outline Dimension                             Left View Front View    Kilotech Inc USA 877 328 5988 CANADA 800 694 4445 3    KWS VS2000 Operation  amp  Service Manual       Right View Back View    If 4 pin socket replace DB9 to be used as load cell connector  and or foot switch is used  the outline is similar  as following shown     RS232 interface             1 2 Power Supply     1 2 1 if 4xAA size alkaline
7.  Working mode  In normal weighing mode  percent weighing mode  or counting mode  long  press FUNC key  one of WEIGH COUNT PERCEN will be shown  use ACC or PRINT key to select BMI   then press TARE to confirm go to BMI mode    7 3 After scale go to this mode  the last stored data  HEIGHT  will be used first    7 4 If you want to change the height  press DATA key to input  When    CM xxx    or    IN xxx    is shown  that  means you can use PRINT  ACC UNIT keys to input your height in centimeter or inch  and use TOTAL to  select input height unit in centimeter and inch  last  press TARE key to confirm and back to BMI working  mode  Press ON OFF key to exit input data mode and back to BMI working mode  The range of height is  50 250cm 19 7 98 4inch  and default is 170cm 66 9inch    7 5 In this working mode  press ACC key to select weight or BMI number to be displayed  when weight is  displayed  the weight unit can be selected by pressing UNIT key  and BMI and weight unit will be  displayed at same time     8  HOLD Function   8 1 HOLD function can be used to freeze display number  In this mode  scale can catch a dynamic number   hold a stable number  or average a unstable number  then HOLD freeze  this number temporary for user  to watch or record  This function can be used in normal weighing mode  counting mode and percent  weighing mode  After entering HOLD mode  the speed of A D converter can be increased to 80Hz  if    Kilotech Inc USA 877 328 5988 CANADA 800 694 4445 15    KW
8.  batteries are used  When all displayed segments of LCD flashed  this prompt  you d better to replace batteries  When    Lo bAt    displayed  this prompt you should replace batteries  immediately  otherwise  it will turn off automatically in 10s    1 2 2 If optional 4xAA NIMH rechargeable batteries package are used  when above cases comes  use  USB or AC adapter to power indicator     1 2 3 AC Adapter  6Vpc 500mA  with central negative   1 2 4 USB power supply if USB interface is installed  e     1 2 5 Work current   lt 15mA  with backlight off  no optional Bluetooth Module and no load cells    lt 30mA  with backlight on  no optional Bluetooth Module and no load cells    lt 50mA  with backlight on and one 350 load cell  no optional Bluetooth Module     The outline of NIMH batteries package is used     Kilotech Inc USA 877 328 5988 CANADA 800 694 4445 4    KWS VS2000 Operation  amp  Service Manual      Connector between PCB and battery package      NIMH battery package       1 3 Display      J Indicator Rear Cover    6 digit 7 segment   1  25mm  LCDs with 16 annunciators and blue backlight    1 4 Keypad  6 push buttons    1 5 Environment     1 5 1 Working temperature   10  C to 40  C  1 5 2 Storage temperature   20  C to 70  C    1 5 3 Humidity  10 to 90  RH without condensation    1 6 Load cell Excitation   1 6 1 Voltage  5Vdc  1 6 2 Max  Current   1 6 3 Signal connection   1 6 4 Max Sensitivity     60mA  can power 4 350 ohm bridge   4 or 6 lead with sense leads   3mV V to  3
9.  details  please refer to section of section5 13  6 6 and 7 6   10  Accumulation    Kilotech Inc USA 877 328 5988 CANADA 800 694 4445 17    KWS VS2000 Operation  amp  Service Manual    10 1 Accumulation function can be used in normal weighing mode  counting mode and percent weighing  mode  When this function is enabled  you can accumulate current net weight  piece  and percentage   Note  only the load on scale is larger than USER OTHER NLD RNG  the displayed positive number can  be added up  The accumulation times and total can be displayed or printed    10 2 To make data accumulation function be available  CONFIG FUNC ACCUMU menu item should set to  MANUAL or AUTO  Following are details    10 3 When CONFIG FUNC ACCUMU is set to MANUAL  the stable and positive displayed net weight  must  be larger than USER OTHER NLD RNG   piece or percentage can be accumulated by long pressing  TOTAL key  and indicator will display accumulation times first  and then display total of number  To avoid  repeating accumulation for same load  one load only can be accumulated once  So  before a new load put  onto the scale  the original load should be removed and let load on scale be smaller than  USER OTHER NLD RNG    10 4 When CONFIG FUNC ACCUMU is set to AUTO  the stable and positive displayed net weight  must be  larger than USER OTHER NLD RNG   piece or percentage can be accumulated automatically  and  indicator will display accumulation times first  and then display total of number  To avoid
10.  repeating  accumulation for same load  one load only can be accumulated once  So  before a new load put onto the  scale  the original load should be removed and let load on scale be smaller than  USER OTHER NLD RNG    10 5 To view total  when display number is zero  long pressing TOTAL key  and indicator will display  accumulation times first  and then display total of number     NOTE  When HOLD function is enable  and scale is working in PEAK HOLD mode  CONFIG HOLD YES   USER HOLD HLD MOD PS PEAK NG PEAK   Accumulation function will be automatically disabled          11  Calibration  Note   CALIBRATION  SHOULD BE 1  PERFORMED BY EXPERIENCED TECHNICIANS 2  AND WITH  ACCURATE CALIBRATION WEIGHTS THAT ARE EQUAL TO MORE THAN 10  OF FS  WEIGHTS     If you do not meet both of the above criteria  you should consult an industrial scale who will  professionally calibrate your scale     12  Display and Set Time  12 1 After entering SETUP mode  by press down SETUP key more than 3s   using PRINT or ACC key to    select MISC TIME item  press TARE to display current time    12 2 Time display Format is  xx xx xx hh mm ss    24h format   12 3 Press down UNIT more than 3s to enter modification time mode  Using HOLD  PRINT  ACC  UNIT   TARE keys to modify current time  If time of no operation is more than 5s  it will automatically exit  modification mode     Kilotech Inc USA 877 328 5988 CANADA 800 694 4445 18    KWS VS2000 Operation  amp  Service Manual    12 4 Press SETUP key to return to 
11. ANADA 800 694 4445 16    KWS VS2000 Operation  amp  Service Manual    8 3 5 Auto HOLD    When USER HOLD HLD MOD is set to AUTO  the hold mode is auto hold mode    different subjects  can be weighed one after another without pressing any buttons  After entering this working mode  scale  will freeze and display number if scale is stable  If scale is not stable  but the variation is less than  USER HOLD DYN RNG  scale will average data in USER HOLD AVGTIM  then freeze and display the  number  Only the weight that is over USER OTHER NLD RNG can be frozen  If the held weight is  moved away  and a new load put on the scale  scale will automatically hold new number of load  Scale  will exit HOLD mode according to the setting of USER HOLD HLD TIM  If the time of scale variation  being over USER OTHER NLD RNG is more than USER HOLD STB TIM  STB ER will be shown   press TARE to start averaging again  or press HOLD key to exit    8 4 In Positive or Negative Peak HOLD mode  the red HOLD  for LED version  or PEAK and HOLD  for LCD  version  announciator will be lighted  in other HOLD mode  green HOLD  for LED version  or HOLD  for  LCD version  announciator will be lighted  When HOLD announciator flash  the displayed number is live   When HOLD announciator become steady  the displayed number is frozen     9  Data Compare Function    9 1 Data compare function can be used in normal weighing mode  counting mode and percent weighing mode   and call it as Check Weigher  Check Counts and Check 
12. KWS VS2000 Operation  amp  Service Manual    Kilotech weighing  scale KWS VS2000    Owner   s Manual    V1 0    Contents Subject to Change without Notice    KWS VS2000 Operation  amp  Service Manual    CONTENT    T  Specification E                                               3  o                                                     7  3  Summary of Key function                                         eeeeeeeeeeeccerenenennne 8  4  Normal Weighing mode                                         eeeeeeeeeererererenenennnn 10  5  Count Weighing Mode                                       eeceeeeeeeeeeeee rere 12  6  Percent Weighing Mode                                                  ecce 14  7  BMI Working Mode ceteris reU ereenn eee 15  8  HOLD UCU lO                15  9  Data Compare Function ss sesessssss esse eee eers sees ennenen eenn 17  OPAC UW AUN s T T 17  11  Display and Set TIG    coco eno contour esse eas ER n pun antt ennenen neee 18  12  Display and Set Date m                             19  13  Meaning of Some Symbols and Troubleshooting                            19  14  Display Character                        23  15 Packing Lisl  isso                                                24  16  Version History de                                                  24       Missing Parts   Scale Not Calibrating   Need Help with Installation     Kilotech Inc USA 877 328 5988 CANADA 800 694 4445    KWS VS2000 Operation  amp  Service Manual    KWS V2000 Indicator Operation
13. ONFIG   menu    5 3 To enter counting working mode  in normal weighing or percent weighing mode  long press FUNC key   WEIGH PERCEN will be shown  use ACC or PRINT key to select COUNT  then press TARE to confirm go  to parts counting mode  Before new piece weight is got  the last piece weight will be used    5 4 In counting working mode  the function of ZERO  TARE  PRINT  HOLD  PRESET TARE  ACC  SETUP   ON OFF are available    5 5 There re two ways to obtain the piece weight   1  input piece weight directly  refer operations of step6 5 1   2 weigh samples weight which quantity is known  refer operation of step6 5 2   5 5 1 Input piece weight from keypad  in counting mode  press UNIT key  When InP PWt is shown  press   TARE key to enter input piece weight mode   5 5 1 1 When UNIT KG is shown  use PRINT or ACC key to select the unit of piece weight  use TARE key to    Kilotech Inc USA 877 328 5988 CANADA 800 694 4445 12    KWS VS2000 Operation  amp  Service Manual    confirm and go to next  Press ZERO key to exit getting piece weight mode and back to counting mode    5 5 1 2 When last stored piece weight is shown  use PRINT  ACC  UNIT key to input new piece weight  press  SETUP key more than 3s to input decimal point  Press TARE key to confirm and save it  then go back  to counting mode  If the input piece weight is less than 0 5d  the indicator will display PWt Er and go  back to counting mode    5 5 2 Obtain piece weight by weighing samples weight which quantity  in counting 
14. Percentage  When this function is enabled  you  can set a higher and a lower limitation of weight   counts or percentage independently  and these  limitation can be saved permanently  Then  the current data of weight   counts or percentage will be  compared with the setting limitation  and corresponding announciator will be lighted    9 2 To make data compare function be available  CONFIG FUNC COMPAR menu item should set to YES   and high and low limitation should be set correctly according to following steps    9 3 In in normal weighing mode  counting mode or percent weighing mode  Press down DATA key more than  3s to enter input compare data of high and low mode    9 4 After HIGH being shown  last setting data of high will be displayed  use PRINT  ACC  UNIT key to input  new number of high and press TARE key to confirm  Announciator of Hi will be shown in this step  Press  ZERO key to exit and back to original working mode    9 5 After Low being shown  last setting of low will be displayed  use PRINT  ACC  UNIT key to input new  number of low and press TARE key to confirm  Announciator of Lo will be shown in this step  Press ZERO  key to exit and back to original working mode     NOTE   f High number is 0 or is equal or less than low number  the comparison will be disabled     9 6 After a reasonable limitation is set and compare function is be active  one of announciators HI  OK  LO will  be lighted  and the beeper will sound according to its setting in USER BEEP    9 7 For
15. S VS2000 Operation  amp  Service Manual    USER HOLD AD H SPD is set to YES  from original 10Hz for some dynamic weighing applications  With  the hold function  it is possible to weigh restless weighing samples such as live animals  moving objects   The indicator provides special mode settings to accommodate sample   s movements    8 2 To make HOLD function be active  the CONFIG FUNC HOLD menu item must be set to YES  menu items  of USER HOLD HLD MOD   AVGTIM   HLD TIM   DYN RNG   STB TIM  USER OTHER NLD RNG  need be set to reasonable value    To speedup sampling of weight  set USER HOLD AD H SPD menu item to YES   To enter HOLD working mode  press down HOLD key when scale works in normal weighing mode   counting mode or percent weighing mode    8 3 There   re several HOLD mode to freeze display data     1  Positive Peak Number HOLD mode   2  Negative Peak Number HOLD mode   3  Toggle HOLD mode   4  Average HOLD mode   5  Auto HOLD mode  The following are details of these HOLD modes    8 3 1 Positive Peak HOLD    When USER HOLD HLD MOD is set to PS PEAK  the hold mode is positive peak hold mode  When  scale first enters this working mode  it will display the largest positive number that is from the time of  zero pint set  After entering this working mode  scale will always catches and refresh positive larger  number and display it  To exit HOLD mode  press HOLD key again    8 3 2 Negative Peak HOLD    When USER HOLD HLD MOD is set to NGPEAK  the hold mode is negative peak hol
16. To enter percent weighing mode  in normal weighing or counting mode  long press FUNC key   WEIGH COUNT will be shown  use ACC or PRINT key to select PERCEN  then press TARE to confirm go  to percent weighing mode  Before new unit percentage weight is got  the last unit percentage weight will  be used    6 4 In percent weighing mode  the function of ZERO  TARE  PRINT  HOLD  PRESET TARE  ACC  SETUP   ON OFF are available    6 5 To obtain the unit percentage weight  there   re two ways    1  input weight and its percentage  then scale  calculates the unit percentage weight  refer operations of step7 5 1  2  weigh samples weight which  percentage is known  refer operation of step7 5 2   6 5 1 Input weight and its percentage from keypad  and calculate unit percentage weight  in percent weighing   mode  press UNIT key  When InP Pct is shown  press TARE key to enter this mode    6 5 1 1 Before input weight  use PRINT or ACC key to select the percentage from 1   2   5   10   20    50  and 100   this percentage is corresponding to the weight you will input in following steps   6 5 1 2 When UNIT KG is shown  use PRINT or ACC key to select the unit of input weight  use TARE key to  confirm and go to next  Press ZERO key to exit and back to percent weighing mode    6 5 1 3 When last stored unit percentage weight data is shown  use PRINT  ACC  UNIT key to input new  unit percentage weight  press HOLD key more than 3s to input decimal point  Press TARE key to  confirm and save it  then go 
17. back to percent weighing mode  If the calculated unit percentage weight  is less than 0 5d  the indicator will display Pct Er and go back to percent weighing mode    6 5 2 Obtain unit percentage weight by weighing samples weight which percentage is known  in percent  weighing mode  press UNIT key  When InP Pct is shown  use PRINT or ACC key to select SPL Pct   press TARE key to weigh samples  which percentage is known  weight  calculate piece weight  Press  ZERO key to exit and back to percent weighing mode    6 5 2 1 When SPL Lo is shown  move away any sample on scale and press TARE key to confirm  before  scale is stable  SPL Lo will be flashed  After it is stable  it will go to next step  Press ZERO key to exit  and back to percent weighing mode    6 5 2 2 When SPL Hi is shown  put samples  its percentage is known  onto the scale  Press TARE key to  confirm reading weight  Before scale is stable  SPL Hi will be flashed  After it is stable  it will go to  next step  Press ZERO key to exit and back to percent weighing mode    6 5 2 3 After INP PCT being shown   000000 position of decimal point is determined by   CONFIG FUNC PERCEN setting  will be displayed  use PRINT  ACC  UNIT key to input the  percentage of samples and Press TARE key to confirm  If the calculated unit percentage weight is    Kilotech Inc USA 877 328 5988 CANADA 800 694 4445 14    KWS VS2000 Operation  amp  Service Manual    less than 0 5d  the indicator will display Pct Er and go back to percent weighing 
18. d mode  When  scale first enters this working mode  it will display the largest negative number that is from the time of  zero point set  After entering this working mode  scale will always catches negative larger number and  display it  To exit HOLD mode  press HOLD key again    8 3 3 Toggle HOLD    When USER HOLD HLD MOD is set to TOGGLE  the hold mode is toggle hold mode    a manual Hold  function  After entering this working mode  scale will freeze and display number if scale is stable  Only  the weight that is over USER OTHER NLD RNG  zero  dead  band   can be held  To exit HOLD mode   press HOLD key again  If the time of scale being unstable is more than USER HOLD STB TIM  STB ER  will be shown  press TARE key to start averaging again  or press HOLD key to exit    8 3 4 Average HOLD    When USER HOLD HLD MOD is set to AVERAG  the hold mode is average hold mode  After entering  this working mode  scale will freeze and display number if scale is stable  If scale is not stable  but the  variation is less than USER HOLD DYN RNG  scale will average data in USER HOLD AVG TIM  then  freeze and display the number  Only the weight that is over USER OTHER NLD RNG can be frozen   Scale will exit HOLD mode according to the setting of USER HOLD HLD TIM  If the time of scale  variation being over USER OTHER NLD RNG is more than USER HOLD STB TIM  STB ER will be  shown  press TARE UNIT ACC or PRINT to start averaging again  or press HOLD key to exit     Kilotech Inc USA 877 328 5988 C
19. g steps    5 6 2 In counting working mode  Press down DATA key more than 3s to input compare data of high and low    5 6 3 After HIGH being shown  000000 will be displayed  use PRINT  ACC  UNIT key to input high quantity  number and press TARE key to confirm  Announciator of Hi will be shown in this step  Press ZERO key  to exit getting piece weight mode and back to counting mode    5 6 4 After Low being shown  000000 will be displayed  use PRINT  ACC  UNIT key to input low quantity  number and press TARE key to confirm  Announciator of Lo will be shown in this step  Press ZERO key  to exit getting piece weight mode and back to counting mode    NOTE  If High number is 0 or is equal or less than low number  the comparison will be disabled    5 6 5 After a reasonable limitation is set and compare is be active  one of announciators HI  OK  LO will be   lighted  and the beeper will sound according to its setting in USER BEEP     Kilotech Inc USA 877 328 5988 CANADA 800 694 4445 13    KWS VS2000 Operation  amp  Service Manual    6  Percent Weighing Mode    6 1 In this mode  scale will weigh goods weight on it  calculate and display its percentage after the  unit percentage weight of goods is obtained   NOTE  If 100  display format is set to 100   100 0  or  100 00  in CONFIG FUNC PERCEN menu item  then  the unit percentage weight is the weight  of 1   0 1  or 0 01     6 2 To make percent weighing function be available  CONFIG FUNC PERCEN menu item shouldn t be set to  NONE    6 3 
20. ibration Seal Switch is on ON position   14 1 45 CAL Er       Calibration error  maybe input data or loaded weight is incorrect  unstable  un linear  14 1 16 CAL End       Calibration is end   14 1 17 OFF       Power OFF the indicator   14 1 18 STB ER         Unstable time is lager than setting of USER OTHER NLD RNG  14 1 19 AC xxxx       Accumulation times is xxxx   14 1 20 PR TARE       To Preset TARE weight   14 1 24 COMP      To go to input COMPARE data mode   14 1 22HIGH       To input HIGH limitation data of Comparison   14 1 23LOW         To input LOW limitation data of Comparison   14 1 24 SPL Lo            Sample load weight of low point    14 1 25 SPL HI             Sample load weight of high point     Kilotech Inc USA 877 328 5988 CANADA 800 694 4445 19    KWS VS2000 Operation  amp  Service Manual    14 1 26 SPL PWT         Sample goods weight to calculate piece weight  14 1 27 INP PCS           input pieces number of weighted goods  14 1 28 UNIT KG           Unit kg is selected   14 1 29 UNIT LB           Unit lb is selected   14 1 30 PWT ER           Piece weight is error  it   s too small    0 5d    14 1 31 SPL PCT          Sample goods weight to calculate   14 1 32 INP PCT           input percentage of weighted goods   14 1 33 PCT ER            Unit Percentage  Weight is too small   lt 0 5d      Kilotech Inc USA 877 328 5988 CANADA 800 694 4445 20    14 2 Troubleshooting    KWS VS2000 Operation  amp  Service Manual                                               
21. ight is 0   turn on when net weight is displaying  and the tare weight is not 0  turn off when gross weight   is displaying   turn on when display data is total times or total of weight  pieces or percentage   turn on when measure unit is Ib or Ib oz   turn on when measure unit is oz or Ib oz   turn on when measure unit is kg   turn on when in percentage weighing mode  measure unit is 96   turn on when in counting mode  measure unit is pieces   turn on when working in BMI mode   turn on when in working in HOLD mode and HOLD type is PEAK HOLD   turn on and flashing not flashing  working HOLD mode and displaying number is isn t live  turns on when data compare is enable and current data  weight  pieces or percent  is over its  upper setting limitation    turns on when data compare is enable and current data  weight  pieces or percent  is  between its high limitation and low limitation   turn on when data compare is enable and current data  weight  pieces or percent  is below  its lower limitation   turn on when battery is used or charged    Kilotech Inc USA 877 328 5988 CANADA 800 694 4445 7    KWS VS2000 Operation  amp  Service Manual    3  Summary of Key function    Weighing Counting Percent    Enter or exit HOLD mode  press down  lt 3s  Weighing Counting Percent    To enter setup mode  press down    3s    Input data mode  press down  gt 3s to input decimal point       Input data mode  press down   3s Return to last sub menu       Menu selection mode Return to last sub menu  
22. last menu item  press ON OFF key to prepare to exit this mode    13  Display and Set Date  13 1 After entering SETUP mode  by press down SETUP key more than 3s   using PRINT or ACC key to    select MISC DATE item  press TARE to display current time    13 2 Date display Format is  xx xx xx yy mm dd    13 3 Press down UNIT more than 3s to enter modification date mode  Using HOLD  PRINT  ACC  UNIT   TARE keys to modify current date  If time of no operation is more than 5s  it will automatically exit  modification mode     13 4 Press SETUP key to return to last menu item  press ON OFF key to prepare to exit this mode    14  Meaning of Some Symbols and Troubleshooting    14 1 Meaning of Symbols     14 1 1 0 e Zero is over the setting range   141 2 0           Zero point is below the setting range   141 3 Ad        Signal to ADC is over max  range    14 1 4 Ad             Signal to ADC is below min  range   141 5          Weight is over upper limitation  or display data is over limitation  14 1 6 5  nee Weight is below lower limitation   14 1 7 EERE1        CONFIG or CAL parameters are not correctly set   14 4 8 EEPE2      USER parameter is not correctly set   14 1 9 Lo bAt           Battery voltage is lower than setting    14 1 10 CAP           Next displaying content is Capacity   14 1 11 CAPER       Parameters about Capacity is not correct   14 1 42 CAL Px       Calibration on point x    14 1 13 CAL OFF       Calibration Seal Switch is on OFF position   14 1 44 CALON         Cal
23. mV V    1 6 5 Load cell Wiring   only be active when corresponding hardware of analog circuit was installed      1 6 5 1 9 holes socket used   Pin1  Excitation    Pin6  Sense    Pin4  Excitation      Pin9  Sense      Pin2 Pin7  Signal    Pin3 Pin8  Signal    Pind  Shield    1 6 5 2 4 pins socket used     Pini  Excitation    Pin2  Excitation      Pin3  Signal    Pin4  Signal      1 7 Communication   1 7 1 Serial port1  Full duplex RS232    AN ep pl     DB9   male Pin     Kilotech Inc    O O  OO    USA 877 328 5988 CANADA 800 694 4445    5    KWS VS2000 Operation  amp  Service Manual    1 7 2 Serial port2  USB  Virtual RS232    1 7 3 Baud Rate  Selectable   1200 2400 4800 9600 19200 38400 bps  1 7 4 Data Output Format  8N1  701  7E1   1 7 5 Protocol  programmable    1 8 Analog Circuit characters   1 8 1 24 bit A D converter  1 8 2 Conversion Speed  10Hz or 80Hz selectable  1 8 3 Input range   15mV to  15mV  1 8 4 Output code  1mV input will output about 100 000 raw counts  1 8 5 With Hardware low pass filter and 2 programmable digital low pass filters    1 9 Capacity and Division  Programmable  1 9 1 Max display range   999 999 to 999 999  1 9 2 Division number range for primary unit  100 100 000  Division number range for second unit  100 150 000   Division number will be limited by REGULA setting   1 9 3 Recommended Sensitivity   gt 1uV  display division    1 10 Accuracy   lt 0 01     1 11 Calibration Method   1 11 1 Software calibration with long term storage in EEPROM  1 11
24. mode  otherwise   after the reasonable unit percentage weight being got  the scale will go back to percent weighing  mode  The got unit percentage weight can be saved after the power off and can be used next time    6 6 Check Percent  percentage compare  in Percent weighing mode    6 6 1 To make percentage compare function be available  CONFIG FUNC COMPAR menu item should set to  YES  and high and low limitation of percentage should be set correctly according to following steps    6 6 2 In percent weighing mode  Press down DATA key more than 3s to input compare data of high and low    6 6 3 After HIGH being shown  000000 will be displayed  use PRINT  ACC  UNIT key to input high percentage  number and press TARE key to confirm  Announciator of Hi will be shown in this step  Press ZERO key  to exit and back to percent weighing mode    6 6 4 After Low being shown  000000 will be displayed  use PRINT  ACC  UNIT key to input low percentage  number and press TARE key to confirm  Announciator of Lo will be shown in this step  Press ZERO key  to exit and back to counting mode    NOTE  If High number is 0 or is equal or less than low number  the comparison will be disabled     6 6 5 After a reasonable limitation is set and compare is be active  one of announciators HI  OK  LO will be  lighted  and the beeper will sound according to its setting in USER BEEP     7  BMI Working Mode  7 1 To BMI working Mode be available  CONFIG FUNC BMI menu item should be set to YES     7 2 To enter BMI
25. mode  press UNIT key   When InP PWt is shown  use PRINT or ACC key to select SPL PWT  press TARE key to weigh  samples  which quantity is known  weight  calculate piece weight  Press ZERO key to exit getting  piece weight mode and back to counting mode    5 5 2 1 When SPL Lo is shown  move away any sample on scale and press TARE key to confirm  before  scale is stable  SPL Lo will be flashed  After it is stable  it will go to next step  Press ZERO key to exit  getting piece weight mode and back to counting mode    5 5 2 2 When SPL Hi is shown  put samples  its quantity is known  onto the scale  Press TARE key to confirm   reading weight  Before scale is stable  SPL Hi will be flashed  After it is stable  it will go to next step   Press ZERO key to exit getting piece weight mode and back to counting mode    5 5 2 3 After INP PCS being shown  000000 will be displayed  use PRINT  ACC  UNIT key to input the  quantity of samples and Press TARE key to confirm  If the calculated piece weight is less than 0 5d   the indicator will display PWt Er and go back to counting mode  otherwise  after the reasonable piece  weight being got  the scale will go back to counting mode  The got piece weight can be saved after the  power off and can be used next time    5 6 Check Counts  counts compare  in Counting mode    5 6 1 To make counts compare function be available  CONFIG FUNC COMPAR item should set to YES  and   high and low limitation of pieces should be set correctly according to followin
26. s Clear the tared weight zi  30 No Tare  Yes No action  No No action Zero      d Yes Clear the tared weight wae em  No zero  S Yes Tare zero and clear the  tared weight  No No action Zero  pone     yes Clear the tared weight us Ec  Europe  No zero  79 Tare zero and clear the  ai tared weight       NOTE   1  ZERO only be active when scale is stable and weight is in SAZSM setting range   2  3    4  TARE weight  make indicator to enter displaying NET mode    TARE only be active when scale is stable  Clear TARE weight or ZERO scale  make indicator to enter displaying GROSS mode    Nm                  4 10 Output data  When scale is stable  press RINT key     4 11 Accumulation   Press ACC key to add displayed number to accumulation memories  and accumulation times will also  add up 1  and then to display accumulation result    4 12 Change Weight UNIT   Short press UNIT key to select kg  Ib or lb oz unit  note  under some condition  Ib oz is not available     Kilotech Inc USA 877 328 5988 CANADA 800 694 4445 11    KWS VS2000 Operation  amp  Service Manual    4 13 Check Weight in weighing mode    4 13 1 To make weight compare function be available  CONFIG FUNC COMPAR item should set to YES  and   high and low limitation of weight should be set correctly according to following steps    4 13 2 In weighing mode  Press down DATA key more than 3s to input compare data of high and low    4 13 3 After HIGH being shown  000000 will be displayed  use PRINT  ACC  UNIT key to input high weight
27. sample   too small to define a valid reference  weight   Unit Percentage  Weight is error  it   s too  small  the weight of 1   0 1   or  PCT ER 0 01  determined by Use a greater weight for the sample   CONFIG FUNC PERCNT is less than  0 5d   SER USER HOLD STB TIM is too short    Set USER HOLD STB TIM longer   USER HOLD HLD RNG is too small  or set USER HOLD HLD RNG       Kilotech Inc    USA 877 328 5988 CANADA 800 694 4445 21          KWS VS2000 Operation  amp  Service Manual       other failure    bigger  Service required       Not turn on     Power cord not plugged in or properly  connected  Power outlet not supplying  electricity  Battery discharged  Other  failure     Check power cord connections   Make sure power cord is plugged  into the power outlet  Check power  source  Replace batteries  Service    required        Cannot zero the display  or will not zero when    turned on     Load on scale exceeds allowable limits     Load on scale is not stable     Load cell damage     Remove load on scale   Wait for load to become stable     Service required        Cannot display weight in  desired weighing unit     Unit not set to enable  or d25o0z when    unit is Ib oz    Enable unit in CONFIG UNITS       Battery symbol is empty  or Lo bAt is shown       Batteries are discharged     Charge batteries          Kilotech Inc    USA 877 328 5988 CANADA 800 694 4445 22       15  Display Character    KWS VS2000 Operation  amp  Service Manual                                            
28. t new zero point   Please refer the ZERO and TARE limitations in 5 9 section     4 6 TARE  When the gross weight is big than zero  and the scale is stable  press TARE key  the indicator will  show net weight of zero  the NET announciator will be lighted  Please refer the ZERO and TARE    limitations in 5 9 section     4 7 Preset tare weight  long press PRESET key  Pr Tare will show  and the TARE announciator flashes  it  means it is in preset TARE weight mode  use       T l         l to input tare weight  and its  unit is    same as the unit that it used before  there   s no limitation to preset tare weight  but it should bigger than  zero  After input a tare weight     NET    announciator will be lighted  Note  this indicator can only save one  tare weight  the new tare weight will automatically replace the old one  Also  please refer the ZERO and  TARE limitations in 5 9 section    4 8 Clear tare weight  remove any weight on platform  wait till the scale is stable  short press TARE key   please refer the ZERO and TARE limitations in 5 9section     Kilotech Inc USA 877 328 5988 CANADA 800 694 4445 10    KWS VS2000 Operation  amp  Service Manual    4 9 Limitation to ZERO and TARE operation under different conditions                                                                                   Standard SS i Data in TARE KEY TURENOR  platform memory unit Tare key Zero key   lt 0 no No action  yes Clear the tared weight  USA m Zero   gt 0 Tare  Yes  p no No action  Gana   Ye
29. ting Percent    Tare function  press down  lt 3s    TARE  Weighing Counting Percent      a To input pre set tare weight at selected weight unit  PRESET press down  gt  3s as S S       dJ input data mode or Menu selection To confirm input data or current item selection  and go to    mode next item of current menu  or next operation       Display ADC code Set or clear  tare  code    Weighing Counting Percent   Zero function  ZERO press down   3s    ON OFF  Weighing Counting Percent     Ey    Power off  press down  gt  3s       Input data mode ignore modification    Menu selection mode Prepare to exit from current working mode  Note     Normally  the second function of one key need pressing it down more than 3 seconds        Kilotech Inc USA 877 328 5988 CANADA 800 694 4445 9    KWS VS2000 Operation  amp  Service Manual    4  Normal Weighing mode    4 1 During key operation  please note to use the second function of one key need pressing the key over 3  seconds  To input data or select menu  use  lt     4 d     e L gt  to process     4 2 Power on scale  when scale is off  short press ON OFF key to turn on   Power off scale  when scale is on  long press ON OFF key to turn off the scale     4 3 Change working mode  long press FUNC key  then ical i   to choose and confirm to enter  into weighing mode  counting mode or percentage working mode    4 4 Enter to or exit from HOLD mode  press HOLD key    4 5 ZERO  When the weights is stable and within the zero range  press ZERO key to se
    