Home
Tektronix DPO3034 datasheet: pdf
Contents
1. Digital Phosphor Oscilloscopes DPO3000 Series Data Sheet Sa A E o R GEUTE amp Features amp Benefits Key Performance Specifications 500 300 100 MHz Bandwidth Models 2 and 4 Channel Models 2 5 GS s Sample Rate on All Channels 5 Megasample Record Length on All Channels 50 000 wfm s Maximum Waveform Capture Rate Suite of Advanced Triggers Ease of Use Features Wave Inspector Controls Provide Unprecedented Efficiency in Waveform Analysis 9 in 229 mm WVGA Widescreen Color Display USB 2 0 Port on Front Panel for Quick and Easy Data Storage USB Plug and Play PC Connectivity TekVPI Probe Interface Supports Active Differential and Current Probes for Automatic Scaling and Units Small Footprint and Lightweight Only 5 4 in 137 mm deep and 9 Ib 4 kg Serial Bus Trigger and Decode Serial Triggering Decode and Analysis Options for 12C SPI RS 232 422 485 UART 2S LJ RJ TDM CAN and LIN Additional Application Support Power Analysis Option HDTV and Custom Video Analysis Option Applications Embedded Design and Debug Investigation of Transient Phenomena Power Measurements Video Design and Debug Automotive Electronics Design and Debug DPO3000 Series Digital Phosphor Oscilloscopes The Power to Solve Problems Quickly The DPO3000 Series digital phosphor oscilloscopes DPO deliver the performance you need to visualize even your most demanding s
2. DPO3COMP DPO3PWR DPO3VID 1 Not available on 2 channel triggering on packet level information on 12S LJ RJ and TDM audio buses as well as analytical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with time stamp information Automotive Serial Triggering and Analysis Module Enables triggering on packet level information on CAN bus and LIN bus as well as analytical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with time stamp information Embedded Serial Triggering and Analysis Module Enables triggering on packet level information on 12C and SPI buses as well as analytical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with time stamp information Computer Serial Triggering and Analysis Module Enables triggering on packet level information on RS 232 422 485 UART buses as well as analytical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with time stamp information Power Analysis Application Module Enables quick and accurate analysis of power quality switching loss harmonics safe operating area SOA modulation ripple and slew rate di dt dV dt HDTV and Custom nonstandard Video Triggering Module models Instrument Options Power Plug Options Option Desc
3. and labor excluding probes CE z ISO 9001 Product s are manufactured in ISO registered facilities E ACOH By THE DUTCH COUN FOR CERTAIN GPIB Product s complies with IEEE Standard 488 1 1987 RS 232 C and with Tektronix IEEE 488 Standard Codes and Formats 11
4. bits 11 bits with Hi Res Max Input 300 Vrms with peaks lt 450 V Voltage 1 MQ Max Input Voltage 5 Vrms with peaks lt 20 V 750 500 DC Gain Accuracy 1 5 with offset set to 0 V Offset Range 1 MQ 50 Q 75 Q 1 mV div to 1 V 1 V 99 5 mV div 100 mV div to 10 V 5 V 995 mV div 1 Vidiv 100 V 5 V 1 01 Vidiv to 100 V NA 10 Vidiv Channel to Channel 2100 1 at 100 MHz and 230 1 at gt 100 MHz up to the rated BW Isolation Any Two Channels at Equal Vertical Scale Horizontal System Characteristic All DPO3000 Models Maximum Sample Rate all channels 2 5 GS s Maximum Record Length all channels 5 M points Maximum Duration of Time Captured at Highest Sample Rate all channels 2 ms Time base Range S div 1 ns to 1000 s Time base Delay Time Range 10 divisions to 5000 s Channel to Channel Deskew Range 100 ns Timebase Accuracy 10 ppm over any 21 ms interval Data Sheet Trigger System Characteristic Description Main Trigger Modes Auto Normal and Single Trigger Coupling DC AC HF reject attenuates gt 50 kHz LF reject attenuates lt 50 kHz noise reject reduces sensitivity Trigger Holdoff Range 20 ns to 8 s Trigger Frequency Readout 6 digit hardware counter indicates how often triggerable events are occurring in the user s signal Sensitivity Internal DC Coupled 0 4 div DC to 50 MHz increasing to 1 div at rated bandwidth External Auxiliary Input 200 mV from DC to 50 MHz increasing to 500
5. Version provides additional signal processing advanced analysis mixed signal sweeping limit testing and user defined step capabilities Order SIGEXPTE for permanent Full Version capability Enables fast and easy communication between a Windows PC and the DPO3000 Series using USB or LAN Transfer and save settings waveforms measurements and screen images IVI Driver Provides a standard instrument programming interface for common applications such as LabVIEW LabWindows CVI Microsoft NET and MATLAB Display Characteristics Characteristic Description Display Type 9 in 228 6 mm wide format liquid crystal TFT color display Display Resolution 800 horizontal x 480 vertical pixels WVGA Waveform Styles Vectors Dots Variable Persistence Infinite Persistence Graticules Full Grid Cross Hair Frame IRE and mV Format YT and XY Waveform Capture Up to 50 000 wim s Rate Input Output Ports Port Description USB 2 0 High speed Supports USB mass storage devices and printers One port Host Port available on rear panel and one on front panel USB 2 0 High speed Rear panel connector allows for control of oscilloscope Device Port through USBTMC or GPIB with a TEK USB 488 or connection to a PictBridge printer LAN Port RJ 45 connector supports 10 100Base T Video Out Port DB 15 female connector connect to show the oscilloscope display on an external monitor or projector Auxiliary Input Front panel BNC connector I
6. easurements Modulation Analysis Graphical display of Pulse Width Pulse Width Period Frequency Duty Cycle and Duty Cycle modulation types Safe Operating Area Graphical display and mask testing of switching device safe operating area measurements dV dt and dl dt Cursor measurements of slew rate Measurements Waveform Math Characteristic Arithmetic Math Functions Description Add subtract multiply and divide waveforms Integrate Differentiate FFT FFT Spectral magnitude Set FFT Vertical Scale to Linear RMS or dBV RMS and FFT Window to Rectangular Hamming Hanning or Blackman Harris Advanced Math Define extensive algebraic expressions including waveforms math functions scalars up to two user adjustable variables and results of parametric measurements both static and trend plots e g Intg Ch1 Mean Ch1 x 1 414 x VAR1 Digital Phosphor Oscilloscopes DPO3000 Series Software Software NI LabVIEW SignalExpress Tektronix Edition OpenChoice Desktop Description A fully interactive measurement software environment optimized for the DPO3000 Series enables you to instantly acquire generate analyze compare import and save measurement data and signals using an intuitive drag and drop user interface that does not require any programming Standard DPO3000 Series support for acquiring controlling viewing and exporting your live signal data A 30 day trial period of the Full
7. ignals Bandwidths range from 100 MHz to 500 MHz and with all models offering a minimum of 5x oversampling on all channels and sin x x interpolation standard you can be confident that even the fastest transient events will be captured and displayed accurately The standard 5 M record length on all channels enables you to capture long windows of signal activity while maintaining fine timing resolution The 50 000 wim s waveform capture rate maximizes the probability of capturing elusive glitches and other infrequent events The DPO3000 Series offers a variety of analytical solutions including cursors 29 automatic measurements statistics and waveform math Despite a tiny footprint only 5 4 in deep and light weight 9 Ib the DPO3000 Series offers exceptional performance a large 9 in WVGA widescreen display and knob per channel vertical controls Tektronix Digital Phosphor Oscilloscopes DPO3000 Series Characteristics Vertical System Characteristic DPO3012 DPO3014 DPO3032 DPO3034 DPO3052 DPO3054 Input Channels 2 4 2 4 2 4 eD Bandwidth 100 MHz 100 MHz 300 MHz 300 MHz 500 MHz 500 MHz 3dB Calculated Rise Time 3 5 Ns 3 5 ns 1 17 ns 1 17 ns 700 ps 700 ps 5 mV div typical Hardware Bandwidth 20 MHz or 150 MHz Limits Input Coupling AC DC GND Input Impedance 1 MQ 41 75 Q 41 50 Q 1 Input Sensitivity Range 1 mV div to 10 V div 1 MQ Input Sensitivity Range 1 mV div to 1 V div 750 500 Vertical Resolution 8
8. ing 2 46 Grus from 5 to 500 Hz 10 minutes each axis 3 axes 30 minutes total Regulatory Electromagnetic 89 336 EEC Compatibility Safety UL61010 1 Second Edition CAN CSA C22 2 No 1010 1 1992 EN61010 1 2001 IEC 61010 1 2001 Ordering Information DPO3000 Series Product DPO3012 DPO3014 DPO3032 DPO3034 DPO3052 DPO3054 Included All models i Description 100 MHz 2 5 GS s 5 M record length 2 channel digital phosphor oscilloscope 100 MHz 2 5 GS s 5 M record length 4 channel digital phosphor oscilloscope 300 MHz 2 5 GS s 5 M record length 2 channel digital phosphor oscilloscope 300 MHz 2 5 GS s 5 M record length 4 channel digital phosphor oscilloscope 500 MHz 2 5 GS s 5 M record length 2 channel digital phosphor oscilloscope 500 MHz 2 5 GS s 5 M record length 4 channel digital phosphor oscilloscope nclude One P6139A 500 MHz 10x Passive Probe per Channel Front Cover 200 5052 xx User Manual Documentation CD 063 4104 xx OpenChoice Desktop Software NI LabVIEW SignalExpress Tektronix Edition LE Software Calibration Certificate Documenting Traceability to National Metrology Institute s and IS09001 Quality System Registration Power Cord Accessory Pouch 016 2008 xx Three year Warranty Please specify power plug and manual language version when ordering Application Modules Module Description DPO3AUDIO Audio Serial Triggering and Analysis Module Enables DPO3AUTO DPO3EMBD
9. lay by Events 1 to 9 999 999 events 1 Not available on 2 channel models Waveform Measurements Description Waveform and Screen 29 of which up to four can be displayed on screen at any one time Measurements include Period Frequency Delay Rise Time Fall Time Positive Duty Cycle Negative Duty Cycle Positive Pulse Width Negative Pulse Width Burst Width Phase Positive Overshoot Negative Overshoot Peak to Peak Amplitude High Low Max Min Mean Cycle Mean RMS Cycle RMS Rising Edge Count Falling Edge Count Positive Pulse Count Negative Pulse Count Area and Cycle Area Mean Min Max Standard Deviation Characteristic Cursors Automatic Measurements Measurement Statistics Reference Levels User definable reference levels for automatic measurements can be specified in either percent or units Isolate the specific occurrence within an acquisition to take measurements on using either the screen or waveform cursors Gating Power Measurements optional Characteristic Power Quality Measurements Description Vrms Verest Factor Frequency Irus Icrest Factor True Power Apparent Power Reactive Power Power Factor Phase Angle Switching Loss Power Loss Ton Tor Conduction Total Measurements Energy Loss Ton Tor Conduction Total Harmonics THD F THD R RMS measurements Graphical and table displays of harmonics Test to IEC61000 3 2 Class A and MIL STD 1399 Ripple Viipple and lippi M
10. mV at 250 MHz Trigger Level Range Any Channel 8 divisions from center of screen External auxiliary input 8 V Acquisition Modes Sample Acquire sampled values Peak Detect Captures narrow glitches at all real time sampling rates Averaging From 2 to 512 waveforms included in average Envelope Min max envelope reflecting Peak Detect data over multiple acquisitions Hi Res Real time boxcar averaging reduces random noise and increases resolution Roll Scrolls waveforms right to left across the screen at sweep speeds slower than or equal to 40 ms div Trigger Modes Edge Positive or negative slope on any channel or front panel auxiliary input Coupling includes DC AC HF reject LF reject and noise reject Pulse Width Trigger on width of positive or negative pulse that are gt lt or a specified period of time Runt Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again Logic Trigger when any logical pattern of channels goes false or stays true for specified period of time Any input can be used as a Clock to look for the pattern on a clock edge Pattern AND OR NAND NOR specified for four input channels defined as High Low or Don t Care Setup and Hold Trigger on violations of setup time and or hold time between clock and data present on any two input channels Rise Fall Time Trigger on pulse edge rates that are faster or slower than specified Slope may be positi
11. nput Impedance 1 MQ Max Probe Compensator Output Trigger Out Kensington Lock input 300 Vams Cat Il with peaks lt 450 V Front panel pins Amplitude 2 5 V Frequency 1 kHz Rear panel BNC connector provides a positive polarity pulse when the oscilloscope triggers Rear panel security slot connects to standard Kensington lock Data Sheet Power Source Characteristic Description Power Source 85 to 265 V 10 Voltage Power Source 45 to 440 Hz 85 to 265 V Frequency Power Consumption 120 W maximum Optional TekVPI Output Voltage 12 V Power Supply Output Current 5 A Power Consumption 60 W Physical Characteristics Dimensions mm in Height 203 2 8 Width 416 6 16 4 Depth 137 2 5 4 Weight kg Ib Net 4 17 9 2 Shipping 8 62 19 Rackmount 5U Configuration 2 in 51 mm required on left side and rear of instrument Cooling Clearance General Characteristics Characteristic Description Environmental Temperature Operating 0 C to 50 C Nonoperating 40 C to 71 C Humidity Operating High 30 C to 50 C 5 to 45 Relative Humidity Low 0 C to 30 C 5 to 95 Relative Humidity Nonoperating High 30 C to 50 C 5 to 45 Relative Humidity Low 0 C to 30 C 5 to 95 Relative Humidity Altitude Operating 3 000 meters 9 843 feet Nonoperating 12 000 meters 39 370 feet Random Vibration Operating 0 31 Grus from 5 to 500 Hz 10 minutes each axis 3 axes 30 minutes total Nonoperat
12. oltage probe with 42 V differential input voltage TDP1000 1 GHz TekVPI differential voltage probe with 42 V differential input voltage TCP0030 120 MHz TekVPI 30 Ampere AC DC current probe TCP0150 20 MHz TekVPI 150 Ampere AC DC current probe TCPA300 400 4 Current measurement systems P5200 1 3 kV 25 MHz high voltage differential probe P5205 4 1 3 kV 100 MHz high voltage differential probe P5210 4 5 6 kV 50 MHz high voltage differential probe P5100 2 5 kV 100X high voltage passive probe ADA400A 4 100X 10X 1X 0 1X high gain differential amplifier DPO3PWRBND Includes P5205 and TDP0500 differential voltage probes Power Solution TCP0030 current probe TPA BNC adapter deskew pulse Bundle generator TEK DPG deskew fixture and power analysis module DPO3PWR in a hard sided carrying case Bundle discount reflected in price 4 Requires TekVPI to TekProbe BNC adapter TPA BNC Recommended Accessories Accessory Description Service Manual 071 2422 xx English only SIGEXPTE NI LabVIEW SignalExpress Tektronix Edition Software TPA BNC TekVPI to TekProbe BNC adapter TekVPI External 119 7465 xx Power Supply TEK USB 488 GPIB to USB adapter Soft Transit Case ACD4000 Hard Transit Case HCTEK4321 requires ACD4000 Rackmount Kit RMD3000 TEK DPG Deskew Pulse Generator 067 1686 00 Deskew Fixture 5 Required when total oscilloscope probe power usage exceeds 20 W Warranty Three year warranty covering all parts
13. ription Opt Ad North America Opt A1 Universal Euro Opt A2 United Kingdom Opt A3 Australia Opt A5 Switzerland Opt A6 Japan Opt A10 China Opt A11 India Opt A99 No power cord Language Options 2 Option Opt LO Opt L1 Opt L2 Opt L3 Opt L4 Opt L5 Opt L6 Opt L7 Opt L8 Opt L9 Opt L10 Opt L99 Description English manual French manual Italian manual German manual Spanish manual Japanese manual Portuguese manual Simplified Chinese manual Traditional Chinese manual Korean manual Russian manual No manual 2 Language options include a translated front panel overlay for the selected language s Service Options Option Opt C3 Opt C5 Opt CA1 Opt D1 Opt D3 Opt D5 Opt R5 Description Calibration Service 3 years Calibration Service 5 years Provides a single calibration event or coverage for the designated calibration interval whichever comes first Calibration Data Report Calibration Data Report 3 years with Opt C3 Calibration Data Report 5 years with Opt C5 Repair Service 5 years including warranty 3 Probes and accessories are not covered by the oscilloscope warranty and service offerings Refer to the datasheet of each probe and accessory model for its unique warranty and calibration terms Digital Phosphor Oscilloscopes DPO3000 Series Recommended Probes Probe Description TAP1500 1 5 GHz TekVPI active voltage probe TDP0500 500 MHz TekVPI differential v
14. ve negative or either Video Trigger on all lines odd even or all fields on NTSC PAL and SECAM video signals Extended Video optional Trigger on 480p 60 576p 50 720p 30 720p 50 720p 60 8751 60 1080i 50 1080i 60 1080p 24 1080p 24sF 1080p 25 1080p 30 1080p 50 1080p 60 and custom bilevel and trilevel sync video standards I2C optional Trigger on Start Repeated Start Stop Missing ACK Address 7 or 10 bit Data or Address and Data on 12C buses up to 3 4 Mbps SPI optional Trigger on SS MOSI MISO or MOSI and MISO on SPI buses up to 10 0 Mbps CAN optional Trigger on Start of Frame Frame Type data remote error overload Identifier standard or extended Data Identifier and Data End of Frame Missing ACK or Bit Stuffing Error on CAN signals up to 1 Mbps Data can be further specified to trigger on lt lt gt 2 or a specific data value User adjustable sample point is set to 50 by default LIN optional Trigger on Sync Identifier Data Id and Data Wakeup Frame Sleep Frame Error up to 100 kbps I2S LJ RJ TDM optional Trigger on Word Select Frame Sync or Data Data can be further specified to trigger on lt lt gt 2 a specific data value or inside or outside of a range RS 232 422 485 UART optional Trigger on Tx Start Bit Rx Start Bit Tx End of Packet Rx End of Packet Tx Data Rx Data Tx Parity Error and Rx Parity Error Trigger Delay by Time 4 ns to 8s Trigger De