Home
installation instructions aut series surgical lights
Contents
1. 7 SECTION INSTAELEATIQN uu uu u etd to editos aa i tea 8 5 1 Typical Installation Sequence Component Identification 8 5 2 Install Wall Control uuu di Mates Ea 9 5 3 Optional Camera Ready Lighthead aa ei ais 12 5 4 Install Fixture Mounting Plate x edit i as 12 5 5 Install Radial Arm Assembly and Ceiling Cover 12 5 6 Install VS T and BON 0 13 5 7 Install AUT7 Lightheads If Applicable 44000 enn 14 5 8 Install Model AUT5 Lightheads If 15 5 9 Fixture Adjustments ore le OH REI HERI DERE Fx nta ei i laze 15 SECTION 6 INSTALLATION DRAWINGS esee ener enhn nenne rrr 16 6 1 Typical Light Fixture and Wiring Requirements AUT55 16 0 2 Typical WiringiDIiagranmis eite tte ta cere 17 6 3 Typical Light Fixture and Wiring Requirements TV Models 18 6 4 Typical Wiring Diagram Models recepere 19 6 5 Standard Mounting Structure Guideline 222 4 10 01 00 20 S
2. SKYTRON INSTALLATION INSTRUCTIONS AUT SERIES SURGICAL LIGHTS STANDARD RADIAL ARM MODELS ONLY Read this manual before starting to work This information is necessary for the safe and efficient operation of the eguipment TEC B 0078 REV3 08 28 14 AND INSTALLATION REQUIREMENTS This product is a Class 2 medical device that is subject to FDA Part 820 requirements Installation can only take place by qualified and trained individuals An Installation Qualification Report is required as proof of system operational validation prior to clinical use Contact Skytron for installation needs Distributed by Manufactured by DKK Dai Ichi Shomei Co LTD US SKYTRON 32 26 Sakashita 1 Chome 5085 Corporate Exchange Blvd S E Itabash i Ku Tokyo 174 0043 Grand Rapids 49512 616 656 2900 JAPAN www skytron us SKYTRON EUROPE BV Floresstraat 52 8022 AD Zwolle THE NETHERLANDS The base language for this document is ENGLISH Any translations must be from the base language document Printed copies are not controlled documents Although current at the time of publication SKYTRON S policy of continuous development makes this manual subject to change without notice If current manuals are required contact your local SKYTRON representative or contact SKYTRON directly at the distribution addresses listed above TABLE OF CONTENTS TITLE PAGE SECTION 1 SAFETY rnnt eere tne re
3. 31IHM 3n18 e UM aan qaad 9 ama Cu vi asna CGD ED Pad o jo PET uno 9 31IHM vs 3 SKYTRON AURORA 3 INSTALL REV3 Page 20 6 5 Standard Mounting Structure Guideline STIFFENER PLATE DETAIL NN lt 6 __y 150mm ZS 4 TOP VIEW S A STIFFENER PLATE provided by others 12 Hole for 300mm Access to Fixture 150mm S m 300 x 300 x 9mm 4 2 x 2 Angle Sway i Stiffener Bracing Plate see note 2 Finished Ceiling Junction Box SN 300mm 12 x 12 x 3 8 2 O 12 X x 2 ANGLE SWAY BRACING 90 APART 4 EACH see note 2 141 32mm 0 NOTES Metal E Flex Conduit P L 6 4 Min see note 3 dRog 150 mm Max 100mm Min _Fixture_ see note 1 T Junction E 5 Box TT E ae MN UD UD LE o RN ee 2 BE Mare TS See uil 2 4 4 60mm S 14 15 380
4. 01 QVAHLHSIT S3MIM LINGNOD TV13IN v 1 N dalddNs NOULAMS 1 TIVM 5 1 Vel3INVO TWNOILdO LINGNOD 1 GV3a3H1H9I1 VYIINVO NOILONn f TOYULNOD V x 1 VH3WVO 1 AURORA 3 INSTALL REV3 9 SKYTRON Page 19 6 4 Typical Wiring Diagram TV Models Bury 415 xoo g 518 o 437 V a37 9T11 wuy uoddns VS eqn p y LSA Ajquessy QN3931 HOLIMS Jeng 104 103002 EM lo MR 9 G 9100 uonounp MOTI3X L zama 4 oC
5. REV3 d Connect the electrical conductors from front face plate assembly to the wiring from the fixture Observe wire markings and colors Avoid undue stress on conductors and internal components N CAUTION Connection of the fixture wires must be made using crimp connectors Main terminal devices shall be so located shielded that should wire ofastranded conductor escape when the conductors are fitted there is no risk of accidental contact between live parts and accessible parts Acceptable shielding methods include UL approved shrink tubing and electrical tape e Make electrical connections using approved crimp connectors Observe wire markings and colors Figure 5 3 f Attach the front panel assembly using the 4 screws removed in Step a Use care to avoid pinching conductors and creating excessive bends in wiring 3 SKYTRON Page 10 OPTIONAL BACK BOX INSTALLATION 120 240 VAC INPUT FINISHED WALL 30 VDC 3 4 CONDUITS TI CONDUIT CONNECTOR ___ RECESS MOUNT FLANGE COVERAGE SINGLE DUAL 1134 W 14 H 298W x 356H SINGLE DUAL BACK BOX TRIPLE 13 W x 17 H 349W x 438H BY W x 115g Hx 4D 215W 295 1030 TRIPLE BACK BOX TOUS 1 1 1 eof x 1930 FRONT EDGE OF BACK BOX MUST BE FLUSH WITH FINISHED WALL SURFACE CONTROL BOX WITH RECESS MOUNT FLANGE INSTALLED CONDUIT AND MOUNTING HARDWARE PROVIDED BY OTHERS BASED ON APPLICATION
6. SURFACE MOUNT 7 SCREW 4 RECESSED MOUNT 2 JUNCTION BOX E L 4 ANCHO DIMENSIONS SINGLE DUAL TRIPLE 8 5 8 220 10 5 8 270 1 B 4 100 4 100 10 5 8 270 14 355 D 6 7 8 175 8 5 8 220 K GJ 7 5 8 195 11 280 F 6 153 6 3 8 162 G 10 255 13 1 2 343 ll 7 7 8 200 10 253 1 5 Y 11 3 4 298 13 3 4 348 H J 13 718 353 17 1 4 438 s i 12 3 8 315 15 3 4 400 SIDE VIEW BACK VIEW L 10 14 260 12 1 4 310 Figure 5 2 Wall Control Mounting Options 3 SKYTRON INSTALL REV3 Page 11 FIXTURE JUNCTION BOX 2 DEDICATED CONDUIT SEPARATE 100 240VAC INPUT SUPPLY LINES FROM TO LIGHTHEAD 2 30VDC SUPPLY LINES TO LIGHT FIXTURE FROM WALL CONTROL TO FIXTURE GROUND GREEN W YELLOW J FROM FACILITY LIGHTHEAD 3 IF APPLICABLE JUNCTION BOX 3 WIRES PER LIGHTHEAD PLUS 1 FIXTURE GROUND NEUTRAL BLUE 100 240VAC LINE BROWN INPUT GREEN LIGHTHEAD AND WALL CONTROL LINE BROWN NEUTRAL BLUE 4 100 240VAC TO 8 1 2 Figure 5 3 Wall
7. Use extreme caution when removing the contents from the crates to prevent damage to the lights Leave the lightheads in their crates until you are ready to install If the lighthead mustbe set down after itis removed from the crate always lay it on the foam shipping block DO NOT lay lighthead on the front face 4 4 Specialty Tools and Equipment The following specialty tools and equipment are required for performing this installation Metric hand tools Appropriately rated lifting device Genie Lift Digital level Torque wrench ft lbs Metric hex sockets 3 SKYTRON Page 8 SECTION 5 INSTALLATION 5 1 Typical Installation Seguence Component Identification The Aurora 3 lighting fixture should be installed in the following seguence Figure 5 1 9 SKYTRON ES lt J SKYTRON ALIRORAS Figure 5 1 Aurora 3 Installation Sequence AUT75 Shown 2 ep So DO Wall Control Mounting Plate Radial Arm Assembly RAA Ceiling Cover Vertical Support Tube VST Balance Mechanism BOM Lighthead Sterilizable Positioning Handle AURORA 3 INSTALL REV3 Page 9 CAUTION Aurora 3 lightheads operate on DC VOLTAGE The PC boards are susceptible to static charges even when not powered Pay close attention to wiring diagrams wire labeling and color codes Wires must remain separate and not touch any other wires or metal parts Incorrect wiring may result
8. yoddns ISA Ajquassy jelpey 3 SKYTRON QN3931 w 175 JAS 5 1 IN AL SINE MOTI3A ama D HOLIMS FON 4 LL cama 1 LN23U9 ama N3349 uoneorunumuo AURORA 3 INSTALL REV3 Page 18 6 3 Typical Light Fixture and Wiring Reguirements TV Models 131100 NV OLNI 1 3H1 ONILYASNI N3HM JHL NOISYJANOJ ASN LON 00 14 3H1 AHL 1 TIIM HOIHM 1 OILANOVW 1V2I4123 13 1 OL NOILVS9IIN AHL OL SANIT LNdLNO SANTI LAdNI DVA0PZ 00 ALVYVdAS OL 1 TIVM 1v SNNY qa1v3Iqaa Z 99 ALV1d HOLO3NNOO 03 4 1 OVAOFTC 00L o 255500 gt 1 6 NOLO gt J LNdLNO 3LIHM N33319 1
9. in incorrect polarity being supplied to the lighthead This WILL DAMAGE internal circuitry and components VOIDING WARRANTY 5 2 Install Wall Control NOTICE 3 4 metal conduit and minimum 12AWG wire 3 wires per lighthead plus fixture ground isreguired between wall control and fixture Flexible conduit should extend 18 below finished ceiling NOTICE Separate dedicated conduitreguired for 100 240VAC supply lines to wall control All wiring to be in accordance with local state and national electrical codes a Removethe front panel assembly from the wall control box for ease in wire connection Remove the 4 screws Set the front panel assembly aside b Installthe wall control box enclosure as desired for the application surface or recessed mount as shown in the wall control illustration Figure 5 2 c Attach recess mount flange if required for recessed applications Figure 5 2 NOTICE Room placement of the wall control will vary by application Always follow current standards from the NFPA National Fire Protection Agency NEC National Electrical Code and IEC International Electrotechnical Commission for proper compliance The selection of anchorage fasteners shall be determined by the engineer of record and will vary by application The selected fasteners must not interfere with wall control components Seismic applications require the use of approved fasteners AURORA INSTALL
10. kl n eeu dn eh kj 2 1 1 Special User Attention 2 1 2 Safety Precautions 2 128 Label u 3 SECTION 2 EQUIPMENT SPECIFICATIONS 4 2 1 Permissible Environmental Conditions cese eene eene enne nnne 4 2 2 Electrical 4 2 3 Sensitive dee aed pe P e FORE 4 2 4 Connection Means nt ct et d e Le vd i cR ER K 4 2 5 National Electric Code NFPA 8 ANSI 4 2 6 Bending RequiIremehtiSs uu a Rud 4 2 7 Conduit 5 2 8 Protective 5 2 9 FinaliAss mbly u u 0 aa teme 5 2 10 Fail Safe DDD 5 2241 rere Ee i CE Ern ERU Er ED RETE DERE S a 5 SECTION 3 MODEL IDENTIFICATION Rt tr PRESE PR 6 SECTION 4 PRE INSTALLATION INSTRUCTIONS essen enne 7 4 1 Pre Installation 8 7 4 2 Installation INOtes a L erae rrr Ge ER LE Dr barbe faces 7 4 3 ncratirig S 0 7 4 4 Specialty Tools and
11. required between wall control and fixture 4 3 Uncrating The SKYTRON surgical lighting fixture is normally shipped in two 2 to four 4 crates depending on the model A carton containing the vertical support tubes VSTs miscellaneous hardware and various instructional materials is packed separately Should any damage to the fixture be noted while uncrating further unpacking should be stopped and the container with all the wrappings held for inspection The transportation company should be notified immediately so an inspector can be sent Consult the Damaged Shipment Claim Procedure sheet for further details Personnel uncrating SKYTRON surgical lights should be aware that they are delicate medical equipment and special care in handling should prevail throughout installation AURORA 3 INSTALL REV3 a Uncrating Light Fixture Open the top of the lighthead box and remove the packing material Remove the sterilizable positioning handle and lighthead from the crate NOTICE Details may vary depending upon model and support structure fabrication All fixtures use METRIC fasteners b Radial Arm Assembly When the radial arm assembly is removed from the crate and set on the floor prior to mounting it be sure the mounting flange is toward the floor If the arm assembly is set on the floor upside down the hub cover may be damaged Figure 4 1 MOUNTING ni Figure 4 1 Radial Arm Assembly c Lightheads
12. 0601 1 and all local codes as applicable 2 6 Bending Requirements Connection leads shall be constructed in such a manner that moveable leads in normal use are not bent around a radius of less than five times the outer diameter of the lead concerned Avoid conditions employing severe bends to ensure the integrity of conductors AURORA 3 INSTALL 2 7 Conduit Reguirements CAUTION This fixture reguires two 2 dedicated conduit raceways at the wall control to separate the 100 240VAC facility supply lines from the DC supply lines to the lighting fixture Failure to observe this requirement will allow the migration of electrical magnetic interference and will disrupt the operation of the lights Use of approved metal conduit shall be employed throughout the fixture s wiring circuit where applicable 2 8 Protective Means N WARNING To avoidtherisk of electric shock this equipment must only be connected to a supply mains with protective earth ground CAUTION This fixture requires a properly circuit protected appropriately sized dedicated circuit An isolated power supply circuit must be protected by an appropriately sized double pole single throw circuit breaker Proper performance and safety of this fixture can only be achieved by an adequate grounding system Fixture ground must be a dedicated ground point ultimately bonded to the facilities grounding system to prevent the migration of electrical in
13. Control Wiring 3 SKYTRON Page 12 5 3 Optional Camera Ready Lighthead The optional camera ready lighthead system includes a connector faceplate with a 65 ft cable that connects to the light fixture junction box The faceplate is mounted in a 2 x 4 junction box and the cable is run through a 1 metal conduit to the light fixture junction box D sub 9 pin connectors are provided for cable connection at the fixture junction box and atthe RAA VST connection point The camera ready lighthead must be installed with the corresponding camera ready BOM and VST Refer to AUT TV fixture diagrams Sections 6 3 and 6 4 5 4 Install Fixture Mounting Plate a Checkthe strength and stability ofthe mounting structure It should be fabricated of steel and welded or bolted to the structural ceiling It should be braced in a manner that will allow no twisting or lateral motion In standard installations a steel stiffener plate should be used to connect the 3 4 diameter all thread support rods andto provide an attachment base for the angle iron sway bracing The 3 4 diameter support rods should be mounted in a 9 1 2 240mm square pattern and should extend 2 1 4 60mm below the finished ceiling NOTICE See mounting structure guideline in Section 6 b Install the SKYTRON mounting plate on the threaded rods between jam nuts Figure 5 4 The plate should normally be located 1 1 4 32m
14. ECTION 7 REVISION AISTORY e a eee a a S 21 AURORA INSTALL 3 SKYTRON Page 2 SECTION 1 SAFETY INFORMATION 1 1 Special User Attention The procedures described in this manual will be performed by representatives of the owner staff or contracted service therefore itis the responsibility of the owner to ensure that all safety precautions are followed Only qualified and trained individuals should attempt the installation of this product 1 2 Safety Precautions The following is a summary of DANGERS WARNINGS and CAUTIONS denoted in this manual These precautions are found throughout the manual where they are applicable Carefully read the manual before proceeding to operate or service the equipment DANGER withthe safety alertsymbol is used to indicate a hazardous situation that if not avoided will result in death or serious injury N WARNING WARNING with the safety alert symbol is used to indicate a hazardous situation that if not avoided could result in death or serious injury To avoid the risk of electric shock this equipment must only be connected to a supply mains with protective earth ground DO NOT remove lighthead when support arm is in down position The BOM will be severely damaged and it may result in bodily injury 9 SKYTRON N CAUTION CAUTION with the safety alert symbol is used to indicate a hazardous si
15. L Page 3 CAUTION CONT D codes Wires must remain separate mE and not touch any other wires or metal This fixture reguires a properly parts Incorrect wiring may result in circuit protected appropriately sized incorrect polarity being supplied to the dedicated circuit An isolated power lighthead This WILL DAMAGE internal supply circuit must be protected by an circuitry and components VOIDING appropriately sized double pole single WARRANTY throw circuit breaker The mounting plate must be accurately SKYTRON surgical lights are packaged leveled within 0 1 to prevent lighthead in special containers designed to drift prevent damage from vibration or shock Always use SKYTRON supplied To prevent support arm damage the containers for shipment longer screws must be installed in the holes towards the lighthead Aurora 3 lightheads operate on DC VOLTAGE The PC boards are NOTICE susceptible to static charges even when not powered Pay close attention to Indicates important information not wiring diagrams wire labeling and color related to personal injury 1 3 Label Symbols With the word DANGER indicates a hazardous situation that if not avoided will result in death or serious injury With the word WARNING indicates a hazardous situation that if not avoided could result in death of serious injury With the word CAUTION indicates a hazardous situation that if not avoided could result in minor o
16. T5 AUT7 AUT5 MODEL AUT75 AUT7TV5 AUT75TV MODEL AUT575 AUT57TV5 AUT575TV 1 30 762mm Diameter Lighthead 1 30 762mm Diameter Lighthead 1 24 610mm Diameter Lighthead 2 24 610mm Diameter Lightheads 3 SKYTRON AURORA 3 INSTALL REV3 Page 7 SECTION 4 PRE INSTALLATION INSTRUCTIONS 4 1 Pre Installation Reguirements Appropriate metal conduit and wiring must be installed from wall control mountto ceiling mounting structure Flexible conduit to extend 18 below finished ceiling 100 240VAC circuit protected dedicated power supply line in separate conduit to be provided at wall control Painting and flooring must be complete prior to fixture installation Finished ceiling height must be verified Optional camera system models require a 1 metal conduit from mounting plate to control unit J box 4 2 Installation Notes Follow the installation instructions and utilize the SKYTRON Surgical Light Installation Report to assure proper installation and to meet the installation qualification requirements Special adapter plates for mounting SKYTRON surgical lights on existing mounting structures are available Contact your SKYTRON representative for special application details Additional materials required for proper installation include Loctite compound Aurora Series lighting fixtures require a wall mounted control box 3 4 metal conduit and minimum 12 AWG wire is
17. d national electrical codes using UL Underwriters Laboratory recognized materials DO NOT turn on main power to fixture until all lightheads are installed connections are complete and the fixture has been reviewed by a SKYTRON representative ELECTRICAL HAZARDS EXIST Exercise caution when working on this fixture the installation of this fixture must be made only by qualified and authorized personnel familiar with the essential knowledge and techniques 9 SKYTRON 2 3 ESD Sensitive Devices When installing devices with electronic circuit boards e g lightheads wall control units appropriate precautions should be taken to prevent damage caused by electrostatic discharge ESD These precautions include as a minimum the use of an ESD wrist strap that is properly connected to an ESD ground 2 4 Connection Means N CAUTION Connection of the fixture wires must be made using crimp connectors Main terminal devices shall be so located or shielded that should wire ofastranded conductor escape when the conductors are fitted there is no risk of accidental contact between live parts and accessible parts Acceptable shielding methods include UL approved shrink tubing and electrical tape DO NOT use damaged wire 2 5 National Electric Code NFPA amp ANSI Requirements The installation of connecting cords between equipment parts shall meet the requirements of the National Electrical Code ANSI NFPA70 IEC 6
18. g axis adjustments and adjust as required Refer to the service manual for instructions on positioning axis adjustments 9 SKYTRON Page 16 INSTALLATION DRAWINGS SECTION 6 6 1 Typical Light Fixture and Wiring Reguirements AUT55 Shown NOILVYAdO AHL LdNYSIG 1 DILANOVW 1 AHL 1 OL 1 OL SANIT 41 1 SANIT 1NdNI DVA0PZ 00 317 97335 OL 1 TIVM 1v SNNY aaivoiaaa 1ndNI OVAOTZ 001 NON LAMS TIVM 1 LNdLNO 3LIHM N3339 day 8 1 1 lt Yad S3MIM ONVZL LINGNOD IVL3M AURORA 3 INSTALL REV3 1 SNILH9STrlI N 1 9 SKYTRON Page 17 6 2 Typical Wiring Diagram Bury oN usnig AHD 2 eAup 99 JOJOBUUOD 081 V 91 11 vs qn
19. l top arm 1 next arm 2 bottom arm triple arm models 3 AURORA 3 INSTALL Page 13 MOUNTING PLATE VST CEILING COVER Figure 5 5 Radial Arm Installation Figure 5 6 Balance Mechanism b Observewire tags and color codes and connect the electrical wires from the wall control to the radial b Follow the tightening sequence and torque the arm junction box wires 5 5 to 9 ft lbs 12 Nm Figure 5 7 c Insert VST of VST BOM assembly into the N RAA receptacle Figure 5 8 Apply Loctite to AUTION screw threads and secure the BOM VST assembly Connection ofthe fixture wires must with the mounting screws following the tightening be made using crimp connectors sequence Figure 5 7 Main terminal devices shall be so 5 located or shielded that should a wire ofastranded conductor escape 67 e 1 when the conductors are fitted there is no risk of accidental contact between live parts and accessible 2 m T 4 parts Acceptable shielding methods include UL approved shrink tubing f and electrical tape Figure 5 7 Screw Tightening Seguence gt 3 c Install the ceiling cover and secure d Remove cap from RAA Figure 5 8 5 6 Install VST and BOM NOTICE Determine correct placement for each BOM VST on the RAA The longest VST goes into the top radial arm a Installthe VST on the BOM apply Blue Loctite to screw threads and secure VST with the Allen screws pro
20. longer screws must be installed in the holes towards the lighthead Figure 5 11 AUT7 Lighthead Installation d Pullthelighthead down and remove the shipping block from the BOM Figure 5 12 N WARNING DO NOT remove lighthead when supportarmis in down position The BOM will be severely damaged and it may result in bodily injury SHIPPING BLOCK Figure 5 12 Shipping Block AURORA 3 INSTALL 5 8 Install Model AUT5 Lightheads If Applicable a make it easier to install the lighthead locate the support arm of the BOM so thatit points inward toward the ceiling cover Figure 5 13 This will prevent the radial arm from moving when installing the lighthead Figure 5 13 Position of Lighthead Installation b Removethe four 4 screws from the lighthead mounting stub c Install the lighthead mounting stub into the support arm and secure with the screws previously removed Figure 5 14 SUPPORT MOUNTING STUB Figure 5 14 AUTS5 Lighthead Installation d Pullthelighthead down and removethe shipping block from the BOM Figure 5 15 N WARNING DO NOT remove lighthead when support arm is in down position The BOM will be severely damaged and it may result in bodily injury AURORA 3 INSTALL REV3 Page 15 SHIPPING BLOCK nN Figure 5 15 Shipping Block e Repeat Steps a through d for each additional AUT5 lighthead 5 9 Fixture Adjustments Check all fixture positionin
21. m off the finished ceiling measured from the bottom of the plate and accurately leveled using a digital level Tighten the jam nuts securely SWAY BRACING STIFFENER PLATE FINISHED FINISHED CEILING CEILING 1 1 4 A 32mm MOUNTING PLATE Figure 5 4 Mounting Plate Installation 9 SKYTRON CAUTION The mounting plate must be accurately leveled within 0 1 to prevent lighthead drift 5 5 Install Radial Arm Assembly and Ceiling Cover NOTICE An appropriate lifting device is recommended for installing each radial arm assembly The weights of the various radial arm assemblies are Radial Arm Assembly Weight Single AUT 5 Radial 58 pounds Arm 26 Single AUT 7 Radial 62 pounds Arm 28 Dual Radial Arm 86 pounds 39 kg Triple Radial Arm 117 pounds 53 multiple arm assemblies are easier to handle during installation if the arms are left taped and tied together In some cases it may be necessary to connect the electrical wires from the wall control to the radial arm junction box before the arm assembly can be bolted to the mounting plate Use two 6 to 8 bolts to hold fixture while connecting wiring a Install the radial arm assembly RAA onto the mounting plate using the 6 bolts provided Figure 5 5 Torque the 1 2 13 mounting bolts to 38 ft Ibs 52 NOTICE Radial arm wires are tagged for proper connection to the wall contro
22. mm dia Mounting Plate SKYTRON Supplied 16 1 2 420 mm dia Access Hole 18 460 mm dia Ceiling Cover SKYTRON Supplied 3 4 support rods located for total support of light all labor and materials for fabrication supplied by General Contractor 3 4 nuts and washers for support of SKYTRON mounting plate supplied by contractor 8 ea required The mounting structure must be attached to structural ceiling and BRACED TO ALLOW NO TWISTING OR LATERAL MOTION and shall be designed not to provide a degree of deflection greater than two tenths of a degree at the mounting plate 3 4 metal conduit and minimum 12AWG wire size 3 wires per lighthead plus fixture ground required between fixture and SKYTRON supplied wall control All metal conduit wiring and other electrical materials as well as installation labor for such materials associated with the installation of the SKYTRON surgical light to be provided by Electrical Contractor All installations of SKYTRON surgical lights should be under the direct supervision of a SKYTRON representative All wiring to be in accordance with local codes and by a certified electrician Optional Camera Ready Systems require a 1 diameter conduit from the fixture junction box to the camera control connector junction box 65 20M camera control cable with faceplate and connector supplied by SKYTRON Conduit and 2 x 4 junction box supplied by General or Electrical C
23. ontractor This is a GENERAL GUIDELINE ONLY 9 SKYTRON CONTRACTOR HAS FINAL RESPONSIBILITY for the strength and stability of the Mounting Structure AURORA 3 INSTALL Page 21 SECTION 7 REVISION HISTORY Dae Revision Revision History 05 07 2013 O O Initial release 05 28 2013 1 Added information to inside cover Throughout the document changed 1 1 4 conduit reguirement to 1 as a correction 02 11 2014 2 New logos deleted white neutral on lightheads in wiring caution added callout to wall control wiring figure deleted separate ground note from installation drawings corrected junction box wiring diagrams 08 28 2014 Added EC REP on inside cover and Label Symbols table on Page3 3 SKYTRON ES SKYTRON 5085 Corporate Exchange Blvd S E Grand Rapids 49512 616 656 2900 FAX 616 656 2906
24. r moderate injury Indicates AC power supply Indicates authorized representative in the european community Indicates Manufacturer Indicates Dangerous Voltage 100 240V 50 60Hz Risk of overbalancing To avoid injuries or equipment damage DO NOT push with excessive force lean on or rest on the lighting fixture AURORA INSTALL 3 SKYTRON Page 4 SECTION 2 SPECIFICATIONS 5 CAUTION This equipment is intended for use by healthcare professionals only This eguipment may cause radio interference or may disrupt the operation of nearby eguipment It may be necessary to take mitigation measures such as re orienting or relocating the lighthead or shielding the location 2 1 Permissible Environmental Conditions a During Transport and Storage in Original Packaging Materials Ambient Temperature 14 to 140 F 10 to 60 C Relative Humidity 10 to 85 No Condensation Atmospheric Pressure 14 to 31 inHg 500 to 1060 hPa b During Use For Dry Locations Ambient Temperature 60 to 85 F 15 to 30 C Relative Humidity 30 to 60 No Condensation Atmospheric Pressure 20 7 to 31 3 inHg 700 to 1060 hPa 2 2 Electrical Requirements CAUTION This fixture requires that electrical connections are made by a licensed electrician in accordance with state local an
25. terference generated by other devices AURORA 3 INSTALL REV3 Page 5 2 9 Final Assembly All installations of SKYTRON surgical lights should be under the direct supervision of a SKYTRON authorized representative Prior to the fixture being placed in service the SKYTRON authorized representative mustinitialize the fixture and complete the installation report To maintain product warranty and performance this product requires routine service Contact your SKYTRON representative for factory service or preventive maintenance contracts 2 10 Fail Safe Compliance In order for dual or triple lighthead systems to maintain fail safe compliance a battery back up UPS or generator back up power system must be provided in the mains wiring prior to the wall control which will restore power five 5 seconds or less NOTICE Fail safe devices are not supplied by SKYTRON 2 11 Shipping CAUTION SKYTRON surgical lights are packaged in special containers designed to prevent damage from vibration or shock Alwaysuse SKYTRON supplied containers for shipment 3 SKYTRON Page 6 SECTION 3 MODEL IDENTIFICATION Standard Radial Arm Configurations MODEL AUT5 AUT5TV 1 24 610mm Diameter Lighthead MODEL AUT7 AUT7TV 1 30 762mm Diameter Lighthead MODEL AUT55 AUT5TV5 AUT55TV gt 2 24 610mm Diameter Lightheads MODEL AUT555 AUT55TV5 AUT555TV 3 24 610mm Diameter Lightheads AUT5 AU
26. tuation that if not avoided could result in minor or moderate injury Connection of the fixture wires must be made using crimp connectors Main terminal devices shall be so located or shielded that should a wire of a stranded conductor escape when the conductors are fitted there is no risk of accidental contact between live parts and accessible parts Acceptable shielding methods include ULapproved shrink tubing and electrical tape DO NOT use damaged wire CAUTION CAUTION without the safety alert symbol is used to address practices notrelatedto personalinjury but with apossibility of damage to equipment This equipment is intended for use by healthcare professionals only This equipment may cause radio interference or may disrupt the operation of nearby equipment t may be necessary to take mitigation measures such as re orienting or relocating the lighthead or shielding the location This fixture requires that electrical connections are made by a licensed electrician in accordance with state local and national electrical codes using UL Underwriters Laboratory recognized materials This fixture requires two 2 dedicated conduit raceways at the wall control to separate the 100 240VAC facility supply lines from the DC supply lines to the lighting fixture Failure to observe this requirement will allow the migration of electrical magnetic interference and will disrupt the operation of the lights AURORA 3 INSTAL
27. vided Figure 5 6 VST Figure 5 8 VST BOM Assembly to RAA e Pull VST and RAA wires and connectors for camera ready VST only up through access hole in RAA Figure 5 9 AURORA INSTALL 3 SKYTRON Page 14 D SUB 9 PIN CONNECTION FOR TV CRIMP CONNECTORS Figure 5 9 Connect VST RAA Wires f Observe the wire colors and connect the wires from the RAA to the corresponding VST wires using crimp connectors Figure 5 9 Connect D sub 9 pin connectors for camera ready VST if applicable g Ensure that all wire connections are secure then place crimped wires and mated connectors inside RAA access hole Re install cap removed in Step d h Repeatprocedure for any remaining BOM VST assemblies 5 7 Install AUT7 Lightheads If Applicable NOTICE Referto Model Identification Section 3 for correct lighthead placement a make it easier to install the lighthead locate the support arm of the BOM so that it points inward toward the ceiling cover Figure 5 10 This will prevent radial arm from moving when installing the lighthead POINT SUPPORT ARM TOWARD CENTER LINE L Figure 5 10 Position for Lighthead Installation 9 SKYTRON b Remove the six 6 screws from the lighthead support arm c Install the lighthead mounting collar onto the support arm and secure with the screws removed in Step b Figure 5 11 CAUTION To prevent support arm damage the