SHEF30 Submersible Sump/ Effluent Pump
Contents
1. No 26230A000 14981 001 1 8507 202 2 834 030 1 14770 005 1 14770 002 1 13507 001 1 14770 006 1 8498 003 1 5484 003 1 5484 001 1 14581 500 1 145 001 1 14770 001 1 1 2 3 4 5 6 7 8 Ring Handle Pipe Plug Motor Housing 0 Ring Pan Screw Pan Screw leg Pan Screw Impeller Seal Rotating Seal Stationary Motor Assembly Stator Screw Screw N r lt lt o RH 600 053 1 139 014 1 75 005 1 14623 010 1 14623 020 1 8521 001 1 14470 010 7 14470 020 7 51752 100 7 51752 101 7 13869 510 5 13869 520 5 Wire with Terminal 0 Ring Cord Nut Power Cord 10 Power Cord 20 Bottom Plate FOR AUTOMATIC OPERATION WIDE ANGLE SWITCH KIT 10 WIDE ANGLE SWITCH KIT 20 DIAPHRAGM SWITCH 10 DIAPHRAGM SWITCH 20 VERTICAL SWITCH 10 VERTICAL SWITCH 20 Limited Warranty HYDROMATIC warrants to the original consumer purchaser Purchaser or You of HYDROMATIC Sump Pumps Effluent Pumps Sewage Pumps other than 2 1 2 and Package Systems that they will be free from defects in material and workmanship for the Warranty Period of 36 months from date of manufacture Our warranty will not apply to any product that in our sole judgement has been subject to negligence misapplication improper installation or improper maintenance Without limiting the foregoing operating a three phase motor with single phase power through a phase converter will void t
2. cord plug may not be making contact in receptacle 4 If pump is using the series piggyback cord plug the two plugs may not be plugged together tightly 5 Float may be stuck Be sure float operates freely in basin 6 If the unit is being operated by the optional float control switch unplug the pump from the piggyback receptacle and plug the pump directly into the power source If the pump starts each time it is plugged directly into the receptacle and does not start each time when plugged into the piggyback switch with the float raised up to a start position replace the complete piggyback switch assembly and retest with new assembly 7 If all symptoms check OK motor winding may be open take to authorized service center for check Pump runs but does not deliver water 1 Check valve may be installed backward Arrow on valve points in direction of flow 2 Discharge shutoff valve if used may be closed 3 Pump may be air locked Start and stop several times by plugging and unplugging cord Hydromaticpumpshave a small air vent hole in the impeller cavity to let out trapped air If this hole becomes plugged pump may air lock To break the air lock use a small screwdriver to clear hole in the impeller cavity As a secondary precaution in installations of this type 1 16 hole should be drilled in the discharge pipe below the check valve The check valve should be 12 to 18 inches above pum
3. SERVICE MANUAL SHEF30 Submersible Sump HYDROMATIC Effluent Pump PENTAIR INSTALLATION AND NOTE TO THE INSTALLER Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system 293 WRIGHT STREET DELAVAN WI 53115 WWW HYDROMATIC COM PH 888 957 8677 269 TRILLIUM DRIVE KITCHENER ONTARIO CANADA N2G 4W5 PH 519 896 2163 2013 Pentair Ltd All Rights Reserved W 03 365 Rev 03 04 13 General Information Thank you for purchasing your Hydromatic pump To help ensure years of trouble free operation please read the following manual carefully Before Operation Read the following instruc tions carefully Reasonable care and safe methods should be practiced Check local codes and requirements before installation Attention This manual contains important information for the safe use of this product Read this manual completely before using this product and refer to it often for continued safe product use DO NOT THROW AWAY OR LOSE THIS MANUAL Keep it in a safe place so that you may refer to it often WARNING Before handling these pumps and controls always disconnect the power first Do not smoke or use sparkable electrical devices or flames in a septic gaseous or possible septic sump California Proposition 65 Warning AWARNING This product and related accessories contain chemicals known to the State of Californ
4. This warranty gives You specific legal rights and You may also have other rights which vary from state to state This Limited Warranty is effective June 1 2011 and replaces all undated warranties and warranties dated before June 1 2011 HYDROMATIC 293 Wright Street Delavan WI 53115 Phone 888 957 8677 Fax 800 426 9446 Web Site hydromatic com
5. he warranty Note also that three phase motors must be protected by three leg ambient compensated extra quick trip overload relays of the recommended size or the warranty is void Your only remedy and HYDROMATIC s only duty is that HYDROMATIC repair or replace defective products at HYDROMATIC s choice You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered No request for service will be accepted if received after the Warranty Period has expired This warranty is not transferable EXCEPTIONS Hydromatic Special Application Pumps Battery Back Up Sump Pumps Filtered Effluent Pumps Grinder Pumps and 2 1 2 Sewage Pumps are warranted for a period of 12 months from date of purchase or 18 months from date of manufacture whichever comes first HYDROMATIC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL INCIDENTAL OR CONTINGENT DAMAGES WHATSOEVER THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied warranty so the above limitations or exclusions may not apply to You
6. ia to cause cancer birth defects or other reproductive harm Pump Warning To reduce risk of electrical shock 1 Risk of Electrical Shock This pump has not been investigated for use in swimming pool areas 2 Risk of Electrical Shock Connect only to a properly grounded receptacle Septic tank is to be vented in accordance with local plumbing codes Do not smoke or use sparkable electrical devices or flame in a septic gaseous or possible septic sump If a septic sump condition may exist and if entry into sump is necessary then 1 provide proper safety precautions per OSHA requirements and 2 do not enter sump until these precautions are strictly adhered to Do not install pump in location classified as hazardous per N E C ANSI NFPA 70 1999 Failure to heed above cautions could result in injury or death Installation Instructions These important instructions must be followed for satisfac tory performance of your pump Before installation check your local electrical and plumbing codes 1 Provide proper sump Minimum Sump Diameter SHEF30 18 Approx Turn On amp Off Level SHEF30 On 9 1 2 Off 3 1 2 Make sure float automatic models hangs free It should not come into contact with side or bottom of sump pit 3 Make sure sump is free of string cloth nails gravel etc before installing pump 4 Do not set pump directly on the bottom of
7. p discharge Do not put check valve directly into pump discharge opening NOTE In sumps where the pump is operating daily air locking rarely occurs 4 Pump head may be too high Pump cannot deliver water over 24 vertical lift Horizontal distance does not affect pumping except for friction loss through the pipe 5 Inlet in pump base may be clogged Remove pump and clean out openings 6 Impeller or volute openings may be plugged or partially plugged Remove pump and clean out Pump runs and pumps out sump but does not stop 1 Float is stuck in up position Be sure float is not hung up and operates freely in basin 2 Switch contacts may be stuck replace switch Pump runs but delivers only small amount of water Pump may be air locked Start and stop several times by plugging and unplugging cord Check vent hole in pump case for plugging 2 Pump head may be too high Pump cannot deliver water over 24 vertical lift Horizontal distance does not affect pumping except loss due to friction through discharge pipe 3 Inlet in pump base may be clogged Remove pump and clean out openings 4 Impeller or volute openings may be plugged or partially plugged Remove pump and clean out 5 Pump impeller may be partially clogged causing motor to run slow resulting in motor overload Clear impeller Fuse blows or circuit breaker trips when pump starts 1 Inlet in pump base may be clogged Remo
8. s recommended that the pump s be cycled every few months to ensure the pumping system is working properly when needed 14 An audible alarm such as the Hydromatic Q Alert for high water conditions should be installed for additional protection against high water conditions NOTE The Q Alert alarm panel is for indoor use only For applications and product information contact your Hydromatic distributor Your pump warranty is void If power cord has been cut If pump has been used to pump mud cement tar abrasives or chemicals If pump has been used for pumping of hot water above 120 F If pump has been dismantled by other than authorized Hydromatic service center or distributor Pump Troubleshooting Servicing should be performed only by an authorized Hydromatic service center WARNING Always disconnect the pump from power source before handling or making any adjustments Always wear rubber boots when there is water on the floor and you must unplug the pump or make any adjustments NOTE Automatic thermal overload protects the sealed in oil motor Running dry may overheat the motor and activate the overload protector until the unit cools Pump does not run or just hums 1 Line circuit breaker may be off or fuse may be blown or loose 2 Water level in sump may be too low to activate automatic switch See installation for proper on off levels 3 Pump and or switch
9. sump if it is not solid Raise the pump by placing bricks or concrete blocks underneath it 5 Use steel or plastic pipe for all connecting lines between pump and sewer outlet NOTE Some city regulations do not allow installing a pump with plastic pipe Check local regulations 6 Hydromatic check valve should be installed in discharge pipe at least twelve inches above the discharge outlet of the pump Install check valve with arrow pointing in the direction of flow 7 A shutoff valve should also be used 8 Connect to power source using 3 prong grounded 115 volt AC receptacle Do not remove ground pin from elec trical plug Do not use an extension cord 9 For proper automatic operation make sure the pump power cord is plugged into the back of the piggyback recep tacle on the switch cord Also ensure that the piggyback plug is securely plugged into the 115 volt grounded receptacle 10 If shutoff valve is used in the discharge line ensure that the valve is open 11 To ensure that the pump is properly installed fill basin with enough water to activate pump see 1 Turn on and off levels Allow pump to go through several on off cycles to assure satisfactory operation 12 Use pump submerged for pumping waterlike liquids temperature to 120 F CAUTION Do not pump flammable liquids strong chemicals or salt water 13 In applications where the pump may sit idle for months at a time it i
10. ve pump and clean out openings 2 Impeller or volute openings may be plugged or partially plugged Remove pump and clean out 3 Pump impeller may be partially clogged causing motor to run slow resulting in motor overload Clear impeller 4 Fuse size or circuit breaker is too small 5 Defective motor stator return to authorized Hydromatic service center for verification Motor runs for short time then stops Then after short period starts again Indicates tripping overload caused by symptom shown l Inlet in pump base may be clogged Remove pump and clean out openings E d LJ OVL SIMI NR LON og ON iios s TES 3A0M38 1 ano OL th NOLLNVD 16 15 14 2 Impeller or volute openings may be plugged or partially plugged Remove pump and clean out 3 Pump impeller may be partially clogged causing motor to run slow resulting in motor overload Clear impeller 4 Defective motor stator return to authorized Hydromatic service center 12 11 SHEF30 Performance Curve I 2 E a lt a lt e e 0 0 Capacity U S G P M 0 Liters Second 0 SHEF30 Typical Installation SHEF30 Parts List Part No 99 776 MN 7 I 7 16 E y y S N Y lt 7177 a 7 A A VILE Part