        Operations & Service Manual
         Contents
1.                                                            ee 50  Front View  Filter  amp  Fan Compartment                                          52  Under Hood ComponentsFilters and SwitcheSs                                    54    Table Of Contents    Safety Model  GVH C  GVH F       Safety Overview    The instructions contained in this manual have been prepared to aid you in learning the proper procedures  for installing and servicing the GVH CF Hood     Throughout this manual  safety precautions are identified through the use of safety alert symbols and  three key words  DANGER  WARNING and CAUTION  All safety alert information will precede the  step s  to which it applies  Suggested  recommended  or otherwise noteworthy information is identified  through the use of NOTES  Additionally  certain words are used to indicate a specific meaning or to add  emphasis     The following words are used as indicated throughout the manual   Shall  understood to be mandatory   Should  understood to be advisory   May  understood to be permissive   Will  indicates a future event or condition is highly likely to occur          or        Safety Alert Symbol    Used in conjunction with key words DANGER  WARNING  or CAUTION to alert you of potential personal  injury hazards and to highlight precautionary measures that pertain to subsequent step s   Adhere to all  safety messages following these symbols to avoid possible injury or death  Failure to comply with safety  precautions identifie
2.                                      7  2 02 2  Clearance to Combustibles  GVH F                                              8  2 03  Cooking Appliance Limitations      Clearances                                      9  2 03 1  Limitations and Clearances  GVH C                                              9  2 03 2  Limitations and Clearances  GVH F                                             10  2 04  Electrical Requirements                                                      11  2 04  1  Electrical Connections                                                       12  2 04 2 Hood      Appliance Wiring                         5                                        ihe  2 04 2 1  Connection w Interlocked Receptacle Option                                     13  2 04 2 2  Connection w Hood      Appliance on same Circult                                 14  2 04 2 3  Connection w  380 480V Appliance Power Separate from 208 240V Hood Power        15  2 04 2 4  Connection w 120V to 480V Appliance Power Separate from 208 240V Hood Power   using Remote Shunt Trip                                                       e 16  2 05  Fire Suppression System    5                                                         17  2 05 1  Fire Suppression System Routing                                  e 18  2 05 2  Fire Suppression Fusible Link Specification  amp  Loccation                            19  20    rire Extinguisher Nozzle LOCaUOFS       ca ose es da eee eee xxm be X RE Fue eor Rs o
3.                                     MAX TOTAL 1 2 CONDUIT LENGTH  95 FT  MAX NUMBER OF 90 DEGREE ANSUL PULLEYS  IO   PART NUMBER 45771     FROM REAR CONNECTION OF HOOD TO AUTOMAN   MAX TOTAL PIPE LENGTH  20 FT  MAX NUMBER OF 90 DEGREE ELBOWS  5        AUTOMAN SWITCH  CONNECTION TO HOOD FOR  FIRE EXTING APPLIANCE  SHUT DOWN    Installation    Model  GVH C  GVH F       2 05 2     NOTE     Fire Suppression Fusible Link Specification  amp  Location    Some of the Fusible Links used in the GVH Fire Suppression System firing circuit are specific to the type  of appliance s  to be served by the hood  See the diagram below for specific manufacturer  temperature    rating and part number     Fusible links are to be installed by an authorized fire protection agent     7             s        STE         A    XQ       ALL APPLIANCES   ANSUL 56811 165  F    GLOBE 314156 165  F                    GRIDDLE  ANSUL 56811  165  F   FRYER  ANSUL 56811  165 F   RANGE  GLOBE 317135  135  F    IF MIXING RANGE WITH OTH  R  APPLIANCE USE GLOBE 317135  135 F                   ALL APPLIANCES     ANSUL 56811 165  F  GLOBE 314156 165 F    7        v    E J    l  I    7     7    NY         LINK TEMPERATURE AND LOCATION    19    Model  GVH C  GVH F Installation    Fire Extinguisher Nozzle Locations              ANSUL 56929 1 2N     L       ANSUL 56929 1 2N      n ANSUL 56929 1 2N  l  I               ANSUL 56930 1W SEE NOZZLE ALIGNMENT         4  a ANSUL 56930 1W SEE NOZZLE ALIGNMENT              NOZZLE TYP
4.                               RR RR Rees 34                                             55                                   usse enue oh E Rem he eae     35  Baffle Filter                                                            RR Ree 9b  EAC Filter Cleaning                            RR RR RR RR ree 36  Charcoal Filter                           suae dob cmd e 99S      dert uu REVUE REY      36  UV Smp     Gaif      94  Replacing te WV EAD suu awas k kus Paes eho ERE TEMPER ES PORRREESPRTSATGS 38  Filter Alarm Chart                                                                         39  Replacing Under Hood Fluorescent                                                   40  Hood Cleaning and                                                      41  Monthly                              33   41  Quarterly Hood Cleaning      42  Fire Suppression System Maintenance                                          42  Semi Annual Fire Suppression Maintenance                                      43  Annual Fire Suppression System _                                      es 43  12 Year Fire Suppression System                                             43  Maintenance and Service Log                                                 44  Troubleshooting                                           n RR Re 46  Troubleshooting Procedures                                  rre 46  Parts List  EP 48  Parts Ordering and Service Information                                         48  Rear Electrical  
5.         EXHAUST CLEARANCE  20 7 8 DOOR SWING                                                                     EY      9 o     mE                          N  D  INSIDE  co 1  D          27 1 2  INSIDE    Y                 lF        29 11 16    2 1 2  N        5T  Rowe EXHAUST    Introduction Model  GVH C  GVH F    1 4 2  Overall Dimensions   GVH F Floor Stand Model             49 15 16  i 20 7 8 28 1 4            18 MIN        CLEARANCE DOOR SWING      aM  aum                                                                      al i  ed  N                       29 5 8     cO INSIDE          FRONT RIGHT    Hood Exhaust Outlet       Model  GVH C  GVH F Introduction    1 4 3  Regulatory Listings            C             LISTED          1 4 4  Hood Weight         Hod Crated Weight Uncrated Weight       GVH C  Counter Top  290 Ibs  131 5 kg  345 165  156 5 kg           Installation Model  GVH C  GVH F       2  Installation    This section summarizes the procedures necessary to install your new GVH C or GVH F Hood  Before  installing and attempting to operate  please read the contents of this manual thoroughly  Following these  procedures will help ensure safe and proper installation     2 01  Unpacking       IMPORTANT NOTE       f the palletized unit showed any signs of damage  you should have immediately inspected the    equipment and any other packed accessories  and promptly notified the freight company of any and all  damages  Typically  it is the customer s responsibility t
6.        _ 8                    LS  m ON  EE  IK IN                              Not shown    ILS Model Only    53    Model  CVH C  CVH F Parts List       Under Hood Components       54    Parts List Model  GVH C  GVH F    7 04  Parts List for Under Hood Components                    55    Model  GVH C  GVH F Parts List       Notes     56                  FOODSERVICE EQUIPMENT       Giles Enterprises  Inc     2750 Gunter Park Drive West    Montgomery  Al 36109 USA  Phone 334 272 1457     Toll Free 800 554 4537  USA  amp  Canada Only     FAX 334 239 4117     www gfse com    Form No  65877  Release date  04 12   Rev  A     
7.   Giles  responsibility for the damage to the unit ends once the freight shipment is loaded onto the carri   ers truck  Upon delivery  if the palletized unit showed any signs of damage  the entire load  including  the supplied accessories  should have been inspected immediately and any damage to the equipment  should have been promptly reported to the freight company        As an aid for electricians and installers  an electrical wiring diagram is provided with the unit  Refer to  the wiring diagram during installation or while servicing     9 Comply with all appropriate state and or local heath regulations regarding cleaning and sanitation of  foodservice equipment     9 Giles recommends the use of mild  bio degradable  non toxic degreasers  such as Clear Magic or  Simple Green  for cleaning parts of the hood where excessive grease film accumulation is present        Always ensure the unit is installed and electrically grounded in accordance with local codes  or in the  absence of local codes  in accordance with the National Electrical Code ANSI NFPA No  70 1984     NOTE      The approximate sound level of the hood while operating is 65 dB     NOTE       For some installations  it may be necessary to consult a HVAC specialist to con   firm that proper room air exchange is occurring and that the on site A C system is  capable of handling the anticipated heat load        Exhaust ventilation is recommended for areas in which recirculating hoods are operated  Giles recom     men
8.   cleaned daily        8      Appliance Receptacle    Optional interlocked appliance receptacle  NEMA   50A max   Allows the under hood appliance to be plugged directly into  the hood  eliminating need for separate appliance power sup   ply          Optional    Not Seen       UnderHood Light       Fluorescent lighting illuminates the appliance area under the  hood     27    Model  GVH C  GVH F    3 03  Accessories  Standard         Description Part Number    Baffle Filter  Double  Hinged   P N 41043    Overview       Function       Removes large particle  contaminant from the air  stream           EAC Filter Assembly  P N 93302    Removes smoke and fine parti   cle contaminant from the air  stream           28       Charcoal Filter  P N 31964       Helps to remove cooking odors  from the discharged air     Overview Model  GVH C  GVH F    Accessories  Standard     Description Part Number Function    EAC Soak Tank Use for soaking and cleaning  P N 39327 EAC filter           Accessories  Optional     Description Part Number Function    Ultra Violet Lamp Sanitizes discharge air and hood  P N 90226 plenum area to aid odor control              29    Model  GVH C  GVH F Overview       NOTES     30    Model  GVH C  GVH F Operation  amp  Filter Maintenance    4  Operation  amp  Filter Maintenance       This section describes Hood operation  care and cleaning of Filters  and other general maintenance items     4 01  Hood Operation    Contirm that all Filters are in place and properly s
9.  AND FITTINGS        WHEN  RECEPTACLE IS              NOT INSTALLED       A                  JN    1                                                     N  N    APPLIANCE AND  HOOD POWER                                                        G  A1 A2 As AN L1 L2 L3  LN  G                                        L       EJ   HOOD AND  UNER HOOD APPLIANCE   POWER    14    Installation Model  GVH C  GVH F    2 04 2 3 Electrical Connection  380 480V Applance Power Separate from  208 240V Hood Power       380 480V APPLIANCE POWER SEPERATE FROM 208 240V  HOOD POWER  USING HOOD SHUNT TRIP CONTACTOR  INCLUDED IN HOOD           USE LIQUID   TIGHT CONDUIT    lina                     Y                    AND FITTINGS  WHEN  lt    RECEPTACLE IS     NOT INSTALLED                 W                                    380 480V APPLIANCE POWER    REMOVE JUMPER WIRES 77                       i                                          G  A1 A2 A3 ANIL 1  L2  LS LN  G  9oI ololololololololo  CE              o             00  o Oo  o 200  o o o      N     S                sad 208 240    APPLIANCE  APPLIANCE HOOD POWER  UNDER HOOD POWER    15    Model  GVH C  GVH F Installation    Electrical Connection  120V to 480V Appliance Power Separate from  208 240V Hood Power w Remote Shunt Trip Device    2 04 2 4       120V to 480V APPLIANCE POWER SEPARATE FROM 208 240 V HOOD POWER  USING REMOTE  SHUNT TRIP CONTACTOR SUPPLIED BY LICENSED ELECTRICIAN   Contactor must be a UL Listed   definite purpose  AC res
10.  Filter and or the Charcoal Filter is missing or not properly  installed    e Filter Clogged light indicates that the Baffle Filter and or the Charcoal Filter is possibly clogged and  requires attention     Filters    e Double Baffle Filter   captures and collects large grease particles entrained in the air stream   e Electronic Air Cleaner  EAC    captures and collects fine particulate air contaminates   e Charcoal Filter   activated carbon filter helps to eliminate cooking odors     Floor Stand Model    e Features a 61 1 2  tall Floor Stand alternative to the standard Countertop model  Total height of Hood  and Stand is 82        1 3  Optional Features    Inter Locked Start  ILS    e Should there be a power interruption to the the hood  this system prevents the hood and the served  appliance s  trom restarting until attended by an operator  This optional provision is required by code in  certain cities and or states     Ultimate Ventless UV     e Ultra violet Lamp Package  working in conjunction with Giles  proven air filtration system  sanitizes the  plenum area and the exhaust air  helping to improve odor control     Model  GVH C  GVH F Introduction    1 3  Optional Features   Continued       Interlocked Appliance Receptacle  e Factory installed  50A  NEMA receptacle ready to accept the appliance power cord  This appliance   plug in  feature provides added convenience     1 4  Specifications    1 4 1  Overall Dimensions   GVH C Countertop Model               56 1 4    18 
11.  Kl  will illuminate and  power to the cooking appliance under the hood is interrupted until  the condition is corrected  The amber Appliance Powered light will  turn OFF     4 02 05  EAC Filter Missing    If the EAC Filter is missing or not properly positioned  all 3 EAC  LED s EX  will illuminate  after approx  2 minutes an intermittent  tone alarm will sound and power to the cooking appliance under the  hood is interrupted until the condition is corrected  The amber  Appliance Powered light will turn OFF        34    Operation  amp  Filter Maintenance Model  GVH C  GVH F       4 02 6  EAC Filter Status    Three L E D  indicator lights on the Control Panel display the status of the EAC Filter System     EB ON when this is the only L E D  ON  the EAC  Filter is in place  powered and operating  properly     5  WASH When       indicates the collection fins are  becoming excessively dirty and must be  cleaned  After approx  2 minutes in this  condition  an intermittent tone alarm will  sound and power to the interlocked under  hood cooking appliance will be interrupted  until the condition is corrected  The amber  Appliance Powered light will turn OFF        CHECK when ON  indicates the Filter is not  operating   here is either a poor  connection at the contacts or the filter is  extremely dirty or damaged  After approx   2 minutes in this condition  an intermittent  tone alarm will sound and power to the  interlocked under hood cooking appliance  will be interrupted until the 
12.  Probable Cause    a  Baffle Filter missing or not    properly installed    Corrective Action    Install Baffle Filter or check  alignment          Baffle Filter missing or not    properly installed    Install Charcoal Filter or check  alignment          Filter switch es  faulty      Baffle or Charcoal Filter    clogged    Replace Filter switch es      Replace Charcoal Filter or clean  Baffle Filter          Hood exhaust outlet    excessively block    Confirm exhaust is clear and min   clearance requirement is met          Vacuum Switch  clogged filter    sensor  is out of adjustment    Have vacuum switch adjusted          Kinked or blocked vacuum    line    Remove vacuum line kinks or  blockage          Fan running slow or blades    are loaded with grease film    Check voltage and inspect blower   clean if needed       Appliance will not heat       e Hood Power light ON   e CHECK and or WASH LED s ON   e APPLIANCE POWERED light OFF   e Intermittent tone  beeping  alarm  sounding      EAC is shorted    Repair or replace EAC cell          EAC excessively dirty    Clean EAC cell          EAC power supply is faulty    Replace EAC power supply          EAC wires shorted to ground    Check voltage  check wiring          Contact Plate is faulty    Replace Contact Plate          EAC driver board is faulty    Replace EAC driver module          Too many EAC ionizer wires    broken or missing    Replace ionizer wires          EAC cell is not installed    Install clean EAC cell        U
13.  accident  misuse  alter   ation  negligence  abuse of the Giles Foodservice Equipment or the use of unorthodox repair meth   ods  All parts replaced under this Limited Warranty carry only the unexpired term of this Limited  Warranty  Limited Warranty service may be furnished only by an authorized Giles Enterprises  Inc    representative     If Limited Warranty service is requested  Giles Enterprises  Inc   will send factory authorized serv   Ice representatives to repair  recondition  replace or inspect units of its manufacture with such labor  being rendered without cost to owner for 24 months from the date of installation  Otherwise  serv   ice  including labor and transportation charges or other expenses  in connection with the removal or  installation of any part or parts supplied under this Limited Warranty  are specified on the original  sales contract between the purchaser and the authorized Giles Enterprises  Inc   representative     Giles Enterprises  Inc  reserves the right to change or improve its equipment and parts in any way  without obligation to alter such equipment or parts previously manufactured     Giles Enterprises  Inc  makes no further warranties  express or implied including implied warranties  of merchantability or fitness for a particular purpose  and has no other obligation or liability not  specifically stated herein     Repair or replacement as provided under this limited warranty is the exclusive remedy  Giles  Enterprises  Inc   shall not be li
14.  deen 20  2 05 4  Fire Extinguisher Nozzle Alignment                                                            2    2 05 5  Final Counter Top Installation  GVH C                                           22  3  OVerVvieW                                                 23  3 01             24  3 02  Hood Front  amp  Filter Chambe                        us xard ie REV M RE sa 26  3 03  Accessories  Standard     oaaae eee          28  3 04  Accessories  Optional                                    29    Model  GVH CF    Model  GVH CF    4   4 01   4 01 1   4 01 2  4 02   4 02 1     4 02 2   4 02 3   4 02 4   4 02 5   4 02 6     4 03   4 03  1     4 03 2   4 03 3   4 03 4   4 03 5     4 04   4 05     9   5 01   5 02   5 03   5 03 1   5 03 2   5 03 3   5 04     6   6 01        Operation      Filter Maintenance                              31  Hood Operation                                                  es      Stating the Hood  Regular              d nuum ad s s BS udo mo ACE ete           Ru A EP Gel Ee 31  Staring the Hoods WLS                 E Petr        EROR GEHT ERES pr RES ue 31  ODE  Fiter        32  Ventless Hood Filter Table                                                    oz  Filter Removal  Baffle          Charcoal                                           33  Filter Installation  Baffle  EAC  Charcoal Filter Installation                            34  Charcoal or Baffle Filter     551    0                                         eee 34  EAC Filter Missing       
15. 0AMP  TOASTER 3 3 4   19   N A TRUE HOOD 500F  INTERLOCK CONTACTOR          Appliance s  exceeding 50 Amps must have a separate circuit from the Hood  but intelocked  through the Hood contactor coil     Model  GVH C  GVH F Installation    2 03 2  Limitations  amp  Clearances  Model GVH F    Hood is listed for Electric Appliances ONLY                 29 5 8 INSIDE 32 1 4 INSIDE          APPLIANCE RESTRICTIONS  MAX  SURFACE   MAX  SHORTENING   MAX MAX        ROGO               CAPACITY TEMP   ELEMENTS  100 TOTAL   MAX 50AMP  FRYER S    5 16 N A THROUGH HOOD 576 SQ  IN  140LBS 9 1 GAL  INTERLOCK CONTACTOR   swoxE                           35                              49         RANGE   278   8 3 4 44 TOTALALLBURNERS   NA         M   4      55 TOTAL   MAX 50AMP  OVEN 1 83 4   19   N A TH ROUGH HOOD N A N A 500F N A  INTERLOCK CONTACTOR   55 TOTAL   MAX 50AMP     5 1 2 19   N A     HOOD 500F  INTERLOCK CONTACTOR   55 TOTAL   MAX 50AMP  TOASTER 1 83 4   19   N A THROUGH HOOD 500F  INTERLOCK CONTACTOR       Appliance s  exceeding 50 Amps must have a separate circuit from the Hood  but intelocked  through the Hood contactor coil        10    Installation Model  GVH C  GVH F    Electrical Requirements      Consult a qualified electrician to ensure that all electrical specifications have been met and that the  unit Is properly grounded        mproper installation  adjustment  alteration  service or maintenance could result in serious injury or  even death  damage to equipment or pro
16. 5122135 45                   1234o J       1  121314  5     J        1   213140  5  j      1 2 5 4 5j j       _ 1   2 3J J4  5J6j J    1  121 1314  5 16   J       1112 3 4  59   J                             5     jJ         1112 3  4  59  J       1121314  5     Pl     _  l  2131 4 151617 2   111 2131 4 5  6 J7  8                1 Door Check   Must be performed  72 effe Fiter Check Wa qn    3         Filter Check Fire Protection     4  Charcoal Filter Check Equipment Company   5 Fiter Clogged    A   7   Fire ouppression System  8              Suppression System replace Fusible Links       Hood Cleaning  amp  Maintenance Model  GVH C  GVH F       Notes     45    Model  GVH C  GVH F Troubleshooting       6  Trouble Shooting    This section describes basic troubleshooting procedures for the GVH Hood  The wiring diagram  attached inside the back cover is provided to assist qualified technicians with more in depth  troubleshooting       Troubleshooting for electrical problems should be performed ONLY by a qualified service technician or  electrician  Serious injury  or even death  will result from contact with energized electrical  components     e Failure to comply with these DANGER notices can result in death or serious injury  equipment or  property damage  and possibly void the warranty     6 01  Troubleshooting Procedures    Problem Probable Cause Corrective Action    Hood will not turn on   Filter Access Door not closed Close  amp  latch Access Door       On ILS Model  PUSH 
17. E AND LOCATION    NOTE   All nozzles are factory installed     20    Installation Model  GVH C  GVH F    2 05 4  Fire Extinguisher Nozzle Alignment       Appliance extinguisher nozzles must be aligned as shown for these appliances     SPLIT FRYER    GRIDDLE       21    Model  GVH C  GVH F Installation    2 06  Final Counter Top Installation  GVH C       Confirm that both the Hood and cooking appliance are properly wired and that installation of the fire    suppression system 15 complete   Ensure that the Hood is located in its final location and that it is suitably level and stable   3  Two  2  Mounting Brackets are provided for securing the Hood to the countertop  The brackets  one  on each side  can be placed at most any position along the Hood s base  but preferably should be  located between the middle to the rear third of the side     Use the supplied 410 x 1 2  self drilling screws to attach the brackets to the Hood base  Use screws  which are appropriate for the counter top material  not supplied  to fasten the Mounting Brackets to           the counter top   Apply a bead of food grade silicone around the entire hood base perimeter to create a liquid tight seal    between the base and counter top surface   The Hood installation must comply with all applicable health and sanitation codes and regulations     NOTE        Before operating the Hood  remove any remaining protective film from the outer surfaces of the Hood  okirt and Base  then clean all exterior surfaces wit
18. Initial Date    _ 1   2  3J4  J5JjJ J       1121 1314  5   j  P       _ 1 ee          1  121314   5 16     A234 J                               5                 _   2 3J J4  5  J                              5   j  J   f       1121314151617  18  115122135 4   5                    _ 1   21314 5 j                              5   Jj       112 3  4  59  j                             5   Jj j     _ 1   2 3J4J J5J6j J    1  121314   5 16   J J     _   2  3J4J J5Jj J      1  121314  5   Jj jJ        a J                              5                1121314151617 18  11512135 45 6 7 gs        1 112 3  4  59   J         1  121314   5     P       1 112 3  4  59  J         1  121314 J J           _ 1 a J                                    pp  v       _ 1   21314  5 j      1 2 35 4 5 J j     1234o J                              5           e     _  1121314151617     1                                            A234 J                              5     PHP        112 3  4  59  J   1     1  121 1314  5     jJ         _ 1   2 3J4 5J6j          1  121314  5 16   J J       _ 1   2 3J4J5  J       1121314  5                 1   21314 5 I                              5   J j    1121314151617    01 1213  4 5 6 7         ee 5 j                              5      jJ       112 3  4  59  J       1  121314     111 2 3 4  51  6   J      1  121 1314  5 16   J J       _   2 3J4J J5  J        1  121314  5     Pp   _ 1   2 3J4  J5J  J                              5                  11213141516 17718  11
19. Operations  amp  Service Manual GVH C  amp   GVH F HOOD       Giles Enterprises  Inc    An ISO 9001 2008 Registered Company    Committed to Quality  2750 Gunter Park Drive West    Montgomery  AL 36109 USA  Phone  334 272 1457     Fax  334 239 4117     Website  www gfse com  Toll Free  800 554 4537  USA  amp  Canada Only     Item No  65877  Release Date 4 2 12  Rev  A        FOODSERVICE EQUIPMENT       LIMITED WARRANTY    Subject to the terms and conditions of this Limited Warranty as herein stated  all Giles Enterprises   Inc   Foodservice Equipment and parts purchased new from an authorized Giles Enterprises  Inc    representative are warranted as to defects in material or workmanship for a period of 24 months  from the date of installation  provided  however  that with regard to labor costs in connection with  this warranty  see below  All installations must be made by a qualified installing agency in accor   dance with all applicable codes and or regulations in the jurisdiction in which installed  Limited war   ranty coverage is extended to the original owner only and is void if the unit is resold     During the Limited Warranty period  Giles Enterprises  Inc  will replace or recondition  at its factory   any part or parts of this unit which Giles Enterprises  Inc  inspectors judge defective  provided the  unit has been subjected to normal usage  properly installed  operated and serviced   his Limited  Warranty does not cover cosmetic damage  and damage due to acts of God 
20. STIBLES       Model  GVH C  GVH F Installation    Clearance to Combustibles  GVH F Model       18  CLEARANCE                                            m   29 5 8  INSIDE    TO COMBUSTIBLES     _     MIN  EXHAUST CLEARANCE 20 7 8 34 5 16  DOOR SWING          z            O          O  E       e                  N        T                                 32 5 16                 INSIDE           36 5 8    0  CLEARANCE RIGHT  TO COMBUSTIBLES    0  CLEARANCE     TO COMBUSTIBLES                                            0  CLEARANCE  TO COMBUSTIBLES       EXHAUST       Installation Model  GVH C  GVH F    2 03  Cooking Appliance Limitations  amp  Clearances    2 03 1  Limitations  amp  Clearances  Model GVH C    Hood is listed for Electric Appliances ONLY              31 7 8 INSIDE         lt      27 1 2 INSIDE                            EAT EATING     gt  REZ              Z    2   M up  AREA 2 VE      MIN  is m                     LLL  1 id     4       APPLIANCE RESTRICTIONS  MAX  SURFACE   MAX  SHORTENING   MAX MAX                   MSS AREA CAPACITY TEMP   ELEMENTS  100 TOTAL   MAX 50AMP  FRYER S    1 1 2 N A THROUGH HOOD 576 SQ  IN  140LBS 9 1 GAL  INTERLOCK CONTACTOR       GmDE  em   834       NA          35             NA          NA                       pa                                N A    55 TOTAL   MAX 50AMP  OVEN 8 3 4 THROUGH HOOD N A 500F N A  INTERLOCK CONTACTOR   55 TOTAL   MAX 50AMP               5 1 2 N A ROUGH HOOD 500F  INTERLOCK CONTACTOR   55 TOTAL   MAX 5
21. TO  START  button not held for at  least 5 seconds       Hold down  PUSH TO START   button for 5 secs          Power Switch is faulty Replace Power Switch        Connect to proper electrical      Improper supply voltage supply          Not properly connected to  power source     Confirm connections  amp  correct          Blown fuse or tripped circuit Check fuse in hood and main  breaker  breaker box     Charcoal or Baffle Filter Missing a  Baffle Filter is not installed or Install Baffle Filter and or check  light illuminated at Initial Start  not properly seated alignment in track   up         Charcoal Filter is not installed Install Charcoal Filter and or check  or not properly seated alignment in track     CHECK and or WASH LED   EAC shorted  damaged  Replace or repair the EAC cell   illuminated  amp  intermittent     beeping  alarm sounding   EAC dirty Clean the EAC cell                EAC high voltage power supply Replace high voltage power  Is faulty  supply          High voltage wires shorted to    ground Correct shorted condition          Faulty EAC contact plate Replace contact plate              46    Troubleshooting    6 01  Troubleshooting Procedures  Continued     Model  GVH C  GVH F       Problem    Appliance will not heat       e Hood Powered light ON   e FILTER MISSING light ON   e APPLIANCE POWERED light OFF    Appliance will not heat       e Hood Powered light ON   e FILTER CLOGGED light ON   e APPLIANCE POWERED light OFF  e Continuous tone alarm sounding   
22. able for any incidental or consequential damages for breach of any  express or implied warranty on this product  except to the extent prohibited by applicable law  Any  implied warranty of merchantability or fitness for a particular purpose on this product is limited in  duration to the duration of this limited warranty     Used Giles Enterprises  Inc   Foodservice Equipment or parts or Giles Enterprises  Inc   Foodservice  Equipment or parts not purchased from an authorized Giles Enterprises  Inc   representative  carry  no warranties  express or implied     Table Of Contents       Safety  n V  Satety Ver VIeV  ues ou amd quad          A           V  Specific Safety PrecautionS                                               eel vi  1                                                                   1  1 01        5                                                                 OS 1  1 02  Standard                                                                            1  1 03  Optional Fealur6eS _           r  ilusi wra e Qa sore eda uu oe bu RE             1  1 04                 2  1 04 1  Overall                                         ad 2  1 04 3  PREG         enra              ean eee                        renee                    Gabe 4  1 04 4  u seal      4  2       1                                                              5  2 01  UNPACKING  s u  sas a  awas waw maa aswa amsa Os            5  2 02       6  2 02 1  Clearance to Combustibles  GVH C          
23. ations     2  Fusible Links specifications are appliance specific  See Section 2 05 2  Fusible Link Specification  amp   Location     3   he remote Manual Actuation Device of the fire extinguishing system shall be readily accessible  in a  path of exit or egress and shall be clearly identified  The installation of the Manual Actuation Device  shall comply with applicable installation standards and codes  The remote Manual Actuation Device  Shall be installed by qualified personnel     4  The Regulated Release Assembly with a 3 Gal suppressant tank shall be a mechanical type  typical  Ansul Automan  79290     5  See Section 2 05 1 for the specific requirements for Fire Suppression System installation     6  The installation  use  and maintenance of this product are to be in accordance with the Standard for  Ventilation Control and Fire Protection of Commercial Cooking Operations  NFPA 96     17    Installation    Model  GVH C  GVH F    2 05 1  Fire Suppression System Routing       PULL STATION    FROM PULL STATION TO AUTOMAN   MAX  TOTAL CABLE LENGTH  I50FT  MAX  NUMBER OF 90 DEGREE PULLEYS  20    CONDUIT FOR WIRING  HOOD APPLIANCE SHUT DOWN  TO AUTOMAN SWITCH       FROM REAR CONNECTION OF HOOD TO AUTOMAN     18    ANSUL AUTOMAN WITH 3 GAL TANK   ANSUL PART NUMBER 79290    USE 3 GALLON ANSULEX EXTING  AGENT   ANSUL PART NUMBER 79372    USE NITROGEN CARTRIDGE LT 30 R   ANSUL PART NUMBER 5373                                            G     1  A2  A3  ANIL 1  L2  L3             
24. cific installation situations and appliance choices  See Section  2 04 2 for specific details of these options     5  Replace all panels and covers   6  Turn on Main Breaker     7  Place the Hood Power Switch in the ON position  Hood fan will start  For ILS model hood  press and  hold the  Push to Start  button on the Control Panel for approximately 5 seconds to start fan     9  f using a remote contactor  Section 2 04 2 4   the contactor must be a UL Listed  definite purpose  AC resistive air heating type  suitable for the appliance load  Installation and connections shall be in    accordance with the National Electric Code NFPA 70        12    Model  GVH C  GVH F    Installation    Hood  amp  Appliance Wiring Configurations    2 04 2   Electrical Connection w Interlocked Receptacle Option    APPLIANCE POWER FROM RECEPTACLE LOCATED IN HOOD  APPLIANCE AND  HOOD POWER ON SAME CIRCUIT BREAKER  USING HOOD SHUNT TRIP    CONTACTOR INCLUDED IN HOOD        h            Wc    h       HOOD AND APPLIANCE POWER                                            G     1                       111        3ILNI G  CE  222                                                               APPLIANCE  AND HOOD POWER          13    Model  GVH C  GVH F Installation    2 04 2 2       Electrical Connection  Hood  amp  Appliance on same Circuit    208 240V APPLIANCE AND 208 240V HOOD POWER ON SAME CIRCUIT  BREAKER                       BIL j                  USE LIQUID    A WC         lt   TIGHT CONDUIT w      
25. clean the UV Lamp every 30 days   1  Place hood Power Switch in the OFF position   2  Open Filter Access             3  The UV Lamp 1 protrudes through the rear wall of the hood and extends into the plenum area  It is  not necessary to remove the lamp to clean it     4  Remove the Charcoal Filter and EAC Filter  if needed     5  Lightly spray a mild  non caustic  bio degradable degreaser  such as Simple Green onto the UV lamp   Allow it to soak for a few seconds and then wipe off residue with a dry  lint free cloth  DO NOT  TOUCH THE LAMP   S GLASS BULB WITH BARE HANDS    Reinstall filters  if removed  and close Filter Access Door   Restart hood as described in Section 4 01 1 or 4 01 2        37    Model  GVH C  GVH F Operation  amp  Filter Maintenance    4 03 2  Replacing the UV Lamp  If Equipped     The UV Lamp must be replaced annually to maintain peak performance  as well as if it is broken or  burned out        1  Place hood Power Switch in the OFF position    Remove screws and carefully lift off the Rear Hood                Carefully unplug the lead  5  of the old lamp from the ballast lead    Remove the two  2  retaining nuts securing the UV Sealing Channel Eo the hood back   Pull the old lamp from the hood plenum and remove the Sealing Channel      When handling the new lamp  DO NOT TOUCH THE GLASS BULB WITH BARE HANDS  Unwrap  new lamp  be certain the o ring 5 in place on the white socket  It must be against the flange  toward the bulb     7  Slide the Sealing Channe
26. condition is  corrected  The amber Appliance Powered  light will turn OFF           IMPORTANT NOTE  e The WASH L E D  is not to be use as an indicator signal for routine cleaning of the EAC cell  The    EAC must be cleaned daily to maintain peak performance  The WASH light being ON is an  indication that the cell is too dirty to function and that power to the cooking appliance is about  to be shutdown     Filter Maintenance    4 03 1  Baffle Filter Cleaning       Grease Baffle Filter should be cleaned daily  Place in sink and clean with a mild  bio degradable   degreaser  Dry filter thoroughly and reinstall in the unit  Generally  the Baffle Filter may be washed in a  dishwasher     Ensure that Baffle Filter is thoroughly dry before reinstalling in the hood  NEVER PLACE AWET  FILTER INTO THE HOOD     35    Model  GVH C  GVH F Operation  amp  Filter Maintenance       The EAC Filter must be cleaned daily for peak performance  Failure to do so will eventually lead to filter  system failure and reduce Charcoal Filter life  Follow the procedure below for effective cleaning        The EAC cell is NOT designed to withstand washing in commercial dishwashers       Do not bend the fins or break the ionizer wires on the EAC as this will prevent the collecting cell  from performing properly and potentially void the warranty        1  Add 1 2 gal  of a mild degreaser  such as Simple Green or Clear  Magic  to the provided Soak Tank  t      add water to the fill line  marked by X s on the i
27. d by a safety alert symbol may also void the equipment s warranty        ndicates an imminently hazardous situation which  if not avoided  will result in serious injury  or even  death  Use of this is limited to the most extreme situations        ndicates a potentially hazardous situation which  if not avoided  may result in serious injury  or even  death        ndicates a potentially hazardous situation which  if not avoided  may result in minor to moderate injury   Also alerts against unsafe practices        When used without the safety alert symbol  CAUTION indicates a potentially hazardous situation  which  if not avoided  may result in damage to the equipment or property  and void the warranty     NOTE      dentifies suggested  recommended  or otherwise noteworthy information        Model  GVH C  GVH F Safety       Specific Safety Precautions    For your safety  please observe the following precautions when operating or servicing the GVH Ventless  Hood  Read the following important safety information to avoid personal injury and or damage to the  equipment or property     9 Always disconnect the source of main power before removing any service panel or cover         Failure to ensure that the Power Switch is in the OFF position during servicing or when replacing filters  could result in damage to the equipment  electrical shock or other serious personal injury     9 Failure to comply with these DANGER notices will result in serious injury or even death  equipment or  pro
28. ds 50 CFM per linear foot of hood space  This amount could vary based on local codes and  site specific situations        viii    Introduction Model  GVH C  GVH F       1  Introduction    Thank You  for purchasing a GVH Series Ventless Hood System manufactured by Giles Enterprises  Inc    Montgomery  Alabama  USA  The GVH C model is designed specifically for use as a counter top hood and  Is listed for the removal of grease laden cooking vapors produced by a variety of small commercial  appliances  The GVH F model is the Floor Stand version     With proper care and maintenance  this unit will provide years of trouble free service  To help protect your  investment in this equipment  we recommend taking a few moments to familiarize yourself with the  installation  operation  cleaning  and maintenance procedures described in this manual  We urge you to  read this manual before installing or operating the hood  Adherence to these recommended procedures  will minimize future potential for costly downtime and equipment repairs  Please retain this manual for  later reference        1 1  Construction    The GVH Hood is constructed of 20 Ga      18 Ga Stainless Steel     1 2  Standard Features       Control Panel    e LED light cluster indicates the status and condition of the Electronic Air Cleaner  EAC  cell    e Appliance Powered light indicates that power is being supplied to the interlocked appliance s   operating under the hood    e Filter Missing light indicates that the Baffle
29. eated before attempting to operate the hood  The Filter  Access Door must be in place and secure  NOTE  The hood will NOT start if the Filter Access Door is  not installed or not properly positoned     4 01 1 Starting the Hood  Regular        Place the Power Switch  Kl in the ON position   The green Hood Powered light will come on   The Hood blower will start    The EAC status ON LED will illuminate     The amber Appliance Powered light  Z will come on     This indicates that power is being supplied to the cooking  appliance under the hood  It can now be operated     ME e        m    6  Should an audible alarm sound  any other indicator lights  come on and or if the Appliance Powered light does not  turn on  refer to Troubleshooting Sections of this manual     4 01 2 Starting the Hood  ILS Model     1  Place the Power Switch  Kl in the ON position     2  Press and hold the Push to Start Button   for approx  5  seconds    3   he green Hood Powered light 3 come on    4  The Hood blower will start    5  The EAC status ON LED  EJ  will illuminate    6  The amber Appliance Powered light      will come on     This indicates that power is being supplied to the cooking  appliance under the hood  It can now be operated     Z  Should an audible alarm sound  any other indicator lights  come on and or if the Appliance Powered light does not  turn on  refer to Troubleshooting Sections of this manual        31    Model  GVH C  GVH F Operation  amp  Filter Maintenance       4 02  Hood Filte
30. ercise care when removing the unit from the shipping skid       DO NOT operate the unit unless you fully understand its components and their intended function        DO NOT bend the collection fins or break the ionizer wires of the Electrostatic Air Cleaner  EAC    Doing so will prevent it from working properly and cause a shutdown of power to the appliance being  operated under the hood     9 Failure to comply with these CAUTION notices may result in minor to moderate injury  damage  to equipment or property  and void the warranty        The electronic components of the Control Panel are somewhat impact sensitive  Exercise care when  performing tasks near the unit s Control Panel to prevent possible unintentional damage     9 After cleaning the EAC  DO NOT attempt to dry the EAC cell by installing it in the hood and running the  fan to force air dry  or by running the appliance under the hood to heat dry  This could potentially dam   age the EAC power system  leading to failure and voiding the warranty  The EAC filter must air dry at  ambient room temperature  preferably overnight        When cleaning the Hood  Hood Skirt or Stand      ee DO NOT steam clean   ee DO NOT spray with water from a hose   ee DO NOT use products containing chlorine   ee DO NOT use abrasive products  steel wool or scouring pads     9 Failure to comply with these CAUTION notices may result in damage to equipment or property  and  void the warranty        vii    Model  GVH C  GVH F Safety    NOTE     
31. formation here for quick future reference     Model Name   Serial Number   Voltage    Phase     Date unit was installed     48    Parts List Model  GVH C  GVH F       49    Model  GVH C  GVH F Parts List         CE Model Only    UV Model Only    50    Parts List Model  GVH C  GVH F    7 02  Parts List for Rear Components    32208  10  11  12  13   20669        TERMINAL BLOCK  73 AMP AWG 620     o o o o o oo  14  15  16  17   18   18        s  807                             s         SE  s  B          CE Miodel Only    UV Model Only    51    Model  GVH C  GVH F Parts List    7 03  Front View  Filter and Fan Compartment         Not shown    ILS Model Only    52    Parts List Model  GVH C  GVH F    7 03  Parts List for Filter and Fan Compartment      98290     BLOWER ASSEMBLY  GVH HOOD               9914   1   COVER FIRE DAMPER  GVH HOOD     O O    41115        DAMPER  FIRE  10 X 10  SHALLOW     o    2157   1   SWITCH  LIMIT 15A  250V     O  24209   1   LED  CLUSTER  EAC FILTER      10   20399   1   INDICATOR LIGHT AMBER  250  O5W     o Z o  11   20898   1   INDICATOR LIGHT  GREEN  250V  O9W o    12   20402   2   INDICATOR LIGHT  RED  250V  05W            13   2190   1   SWITCH  ROCKER  D PS T 250V  10A        o  4   5   42827   1   DOOR LATCH  COMES WITH STRIKE              16   4122   1   OUTERDOORGASKT                  O  7   4116   2   GASKET EAC  amp  CHARCOAL FILTER  Z o O    18   46   1   GASKET BAFFLE FILTER               1                                          2    
32. h a good quality stainless steel cleaner polish                   i        NW       T  AA           SSS   jl    Appropriate Fastner   Not Supplied        Self drilling  Screws    Supplied     S         Bracket                                     Silicone    22    Overview Model  GVH C  GVH F       3  Overview    The following section provides a brief overview of the components  functions  and accessories of the  GVH Ventless Hood  Please review this section carefully before attempting to operate the unit     Hood Exhaust    Filter Access  Door        Control Panel    Drip Cup    23    Overview    Model  GVH C  GVH F       3 01  Control Panel         ILS Only    24    Overview    3 01  Control Panel    Item    Description       Model  GVH C  GVH F    Function                                  The Power Switch is a two position Switch  Placing switch in  1 Power Switch the ON position starts the hood fan and turns on the under   hood light     PUSH TO START After placing Power Switch in the ON position  push and hold  2 Suitor button for approx  5 seconds to start the hood fan  Only on  units with Inter Locking Start  ILS  option installed   This Light is illuminated when the Power Switch is in the ON    position and the Filter Access Door is properly closed  If  3 MOOO ENEE equipped with the ILS  the start button must have also been  depressed     Light is illuminated to signify that the appliance under the     Appliance Fowered Light hood is receiving power and ready to turn o
33. in the OFF position  ensure that the cooking appliance s  under the  hood is adequately cool before attempting to replace bulb     2  Remove retaining screws from the Light Cover Assembly 2 and remove   3  Remove the old fluorescent bulb E replace with new  T5   14W   22  fluorescent tube  Giles P N  20616        Replace Light Cover Assembly   5  Restart hood as described in Section 4 01 01 or 4 01 02       40    Hood Cleaning  amp  Maintenance Model  GVH C  GVH F    5  Hood Cleaning  amp  Maintenance       This Section describes the steps to generally maintain and clean the GVH Hood system  Attention to  these procedures will helo ensure the hood remains in good operating condition and continues to run  efficiently and safely     A Maintenance  amp  Service Log is provided in this manual  see Table 5 6     5 01  Monthly Interlock Check       The Hood design incorporates various interlock devices to ensure that the unit will shutdown in the event that  certain conditions exist that are not consistent with safe and effective operation  These interlocks should be  tested MONTHLY as described below  Use the Maintenance  amp  Service Log and place a check in the box  that corresponds to each functional test  If a problem is found  contact a service provider     1  Door Interlock Check  Turn power switch ON  With Hood running  unlatch and slightly open the  Filter Access door  Confirm Hood powers off when door is opened  Check the underhood  appliance to ensure that it cannot be t
34. istive  air heating type  suitable for the appliance load  The Installation and  connections shall be in accordance with the National Electric Code NFPA 70     USE LIQUID          TIGHT CONDUIT B  gt f      AND FITTINGS     bs    WHEN 10     RECEPTACLE IS   cu ER      NOT INSTALLED     a    em  2       E               LL   Y                  l                          N      N      Ni             APPLIANCE POWER AND  CONTACTOR COIL SIGNAL  TO SHUNT TRIP DEVICE                                            G           2               1  L2  L3  L NI G                                            208 240                    HOOD POWER  CONTACTOR COIL                   REMOTE SHUNT TRIP APPLIANCE  APPLIANCE CONTACTOR POWER  UNDER HOOD    16    Installation Model  GVH C  GVH F    2 05  Fire Suppression System Installation       It is required that the Giles GVH Ventless Hood System be protected by a UL listed fire suppression  system  Procurement  final installation  testing and certification of this system is the responsibility  of the customer and must be performed by a qualified Fire Protection Agent in accordance with the  hood system listing     The GVH hood includes factory installed suppressant piping  plenum and appliance discharge nozzles   fusible link brackets  cable conduit and wire cable  Piping and conduit are stubbed on the hood back   ready for hook up     1  Discharge Nozzles  Appliance  56930 1W     Plenum  56929 1 2N  see Section 2 05 3  Fire  Extinguisher Nozzle Loc
35. it to operate        Baffle Filter    First stage of the grease extraction and aircleaning system   This filter is easily removed for daily cleaning  To avoid possi   ble electrical shock  DO NOT remove while the hood Power  Switch is ON  The Baffle Filter should be cleaned daily        EAC Filter    EAC Filter is an electrostatic device that removes grease vapor  and smoke generated during cooking  To avoid possible  electrical shock  DO NOT remove while the hood Power  Switch is ON  The EAC must be cleaned daily        Charcoal Filter    Charcoal Filter helps to eliminate cooking aromas from the dis   charge air  This Filter should be replaced monthly  To avoid  possible electrical shock  DO NOT remove the Charcoal  Filter while the hood Power Switch is ON  NEVER attempt  to clean and re use the Charcoal Filter  Replace with new  filter every 30 days               UV Lamp    Optional 4th stage of air cleaning  helps sanitize discharge air  and the hood plenum area to further aid with eliminating  cooking aromas  The UV Lamp should be cleaned monthly  and replaced annually        Air Exhaust Outlet    The Exhaust Outlet located on top of the unit  exhausts the  filtered air back into the room  For proper air flow  a mini   mum clearance of 18  must be maintained between the  top of the hood and the ceiling  or other overhead  obstruction        Grease Drip Cup    The Grease Drip Cup catches grease condensate generated  at the Baffle Filter  This container must be emptied and
36. l nozzles to ensure they are free of grease build up  Confirm that all nozzle caps are in place  and in good condition  replace as needed  See Section 2 05 03  Fire Extinguisher Nozzle  Locations     4  Test and inspect the remote manual pull station for activation and wear   5  Install test link and cut to simulate automatic actuation     6  Clean and inspect fusible links  Confirm all fusible link temperature ratings are correct for the  appliance s  under the hood  See Section 2 05 2  Fire Suppression Fusible Link Specifications  amp   Location     7  Inspect fusible link conduit and wire cable for wear at pulleys and detectors  replace if necessary     8  Record maintenance date and service performed in a permanent file  and sign off on tag attached to  system     5 03 2  Annual Fire Suppression System Maintenance       Same as Semi Annual Maintenance except that all fusible links must be replaced with new  See Section  2 05 2  Fire Suppression Fusible Link Specifications  amp  Location    5 03 3 12 Year Fire Suppression System Maintenance       Same as Annual Maintenance except for the following   1  Replace fire suppressant chemical     2  Hydrostatic testing of the suppressant holding tank and charging cartridge  Acceptable to replace  with new components that have current hydrostatic certification     3  Flow test the regulator     43    Model  GVH C  GVH F Hood Cleaning  amp  Maintenance       5 04  Maintenance      Service Log    Check Initial Date                  
37. l over the cord and seat it against the socket flange     B   GUI          45    9  Place the new lamp through the hole jon the hood back and insert fully until the o ring is seated  against the wall  Reinstall retaining nuts to secure channel and lamp     9  Plug Lamp lead into ballast lead and secure excess wire     10  Restart hood as described in Section 4 01 1 or 4 01 2        38    Operation  amp  Filter Maintenance    4 04     Alarm Sound    Continuous tone    Filter Alarm Chart    What will happen    Alarm sounds  Charcoal or Baffle  Filter Clogged lamp illuminates   and power to the appliance 15  shutdown  Appliance Powered  light is OFF     Filter  affected    Charcoal    Model  GVH C  GVH F    Cause    Filter dirty  Or  otherwise  clogged    Solution    Replace Filter    See Section    4 02 02   amp   4 02 03        Continuous tone    Alarm sounds  Charcoal or Baffle  Filter Clogged lamp illuminates   and power to the appliance 15  shutdown  Appliance Powered  light is OFF     Filter dirty  Or  otherwise  clogged    Hemove and  clean Filter       Intermittent tone       Check and or Wash LED s are  illuminated  alarm sounds and after  approx  2 minutes  power to the  appliance is shutdown  Appliance  Powered light is OFF           Filter dirty  Or  damaged       Clean Filter   Replace or  repair Filter if  needed          39    Model  GVH C  GVH F Operation  amp  Filter Maintenance    4 05  Replacing Under Hood Fluorescent Light       1  Place hood Power Switch IN 
38. n for use     The ON Indicator Light is illuminated when the Electronic Air     on         Cleaner  EAC  power supply is on  If the EAC is functioning   EAC  normally  this will be the only LED illuminated   The WASH Indicator Light is illuminated when the EAC  becomes excessively dirty  This is NOT a signal for routine  6 WASH LED Indicator cleaning  the EAC must be cleaned daily for best perform    EAC  ance  Failure to do so will significantly reduce the life of the  charcoal filter and possibly cause damage to the EAC power  supply   The CHECK Indicator Light will illuminate when the EAC cell  CHECK LED Indicator becomes shorted  The EAC nas stopped functioning  an alarm  7 EAC will sound and the cooking appliance will be disabled two  2       minutes after the CHECK light comes on  The EAC must be  cleaned or is need of repair or replacement   9 Clogged Filter Indicator Light will illuminate if the Baffle Filter or Charcoal Filter is   Battle or Charcoal  dirty clogged   9 Filter Missing Indicator Light will illuminate if either the Charcoal or Baffle Filter is   Battle or Charcoal  missing or installed improperly     ILS Only    25    Model  GHV C  GVH F Overview    3 02  Hood Front  amp  Filter Chamber         Optional    Not Seen    26    Overview    Model  GVH C  GVH F    Hood Front  amp  Filter Chamber    Description    Filter Access Door    Function       Provides access to the Baffle Filter  EAC and Charcoal Filter   This door must be closed and latched for the un
39. nder hood lighting does not  come on when Power Switch is  placed in ON position      Fluorescent bulb burned out    Replace bulb          Ballast is faulty    Replace ballast             Fuse is blown       Check and replace fuse        47    Model  GVH C  GVH F Parts List    7 Parts List    This section lists the various field replaceable parts available for the GVH Hood        7 01  Parts Ordering and Service Information    If you require assistance or need repairs  please contact a Giles Manufacturer s Representative or Dealer  to assist with locating an authorized service provider in your area  For further assistance  please contact  Giles Enterprises directly at the following phone numbers     IN THE UNITED STATES  CANADA or MEXICO    Call 800 554 4537 during normal business hours  8 00 AM to 5 00 PM Central Time  other than normal  business hours  call 800 554 4537 and follow recorded prompts to reach after hours support        IN ALL OTHER COUNTRIES    Call 334 272 1457 during normal business hours  8 00 AM to 5 00 PM Central Time  other than normal  business hours  call 334 272 1457 and follow the recorded prompts        The goal of the Giles team is to provide you with the highest quality service and assistance possible  To  help us accomplish this please have the following information readily available when calling  along with the  nature of the problem you are encountering  This information is recorded on a Serial Plate or Label  attached to the unit     Record in
40. nside of the tank back and mix thoroughly     2  Grasp the cell s contact plate  5  and carefully lower the EAC       into the mixed degreasing solution     3  Allow the EAC to soak for 30 minutes  After that time  grasp the  cell by the contact plate 2  lift it and agitate up and down in the  solution several times to dislodge grease residue     4  Carefully remove the EAC from the tank and rinse thoroughly in a  sink using hot water spray        5  Stand cell on end with contact plate up and allow to air dry  overnight     6  Inspect cell for broken wires or bent fins  Any broken wires need  to be replaced promptly  Bent fins may be gently straightened by  hand  if needed       With proper care  cleaning  and handling  the EAC cell is designed to provide years of service  It  is important that it be cleaned daily as described above     4 03 3  Charcoal Filter Maintenance      NEVER attempt to clean and re use the Charcoal Filter  Damage to the unit could result        The Charcoal Filter cannot be cleaned     it is to be replaced ONLY     Replace the Charcoal Filter every 30 days using replacement Part No  31964  It is advised that the  installation date be recorded in the space provided on the new filter s label     36    Operation  amp  Filter Maintenance Model  GVH C  GVH F       4 03 2  UV Lamp Cleaning  If Equipped     e   DO NOT touch or handle the glass portion of the UV Lamp with bare hands  This will greatly  reduce the life of the bulb        It is recommended to 
41. o claim freight damage           The unit is shipped on a wooden skid with protective framing  secured to the skid by high tensile plastic  strapping and wrapped with machine applied stretch wrap  Perform the following steps to unpack the  unit    1  Position the palletized unit in an area with sufficient space for unpacking    2  Cut and remove stretch wrap and all strapping    3  Use appropriate tools to remove the wooden crate from around the unit    3      Remove any packed accessories from the skid and set aside   f a Floor Stand model  carefully uncrate  the Hood Stand pieces and set aside for later assembly     4  The unit is extremely heavy  Using suitable lifting equipment or adequate manpower  lift the unit and  remove it from the shipping skid  See Section 1 4 4  Hood Weights     5  Properly dispose of all shipping materials     The unit is extremely heavy and somewhat top heavy  Exercise due caution when handling to avoid  personal injury or damage to the equipment  lake precautions not to damage the hood s Base or  okirting     Exercise care when removing the wooden framing from around the unit to avoid any exposed nails or  staples     Failure to comply with these CAUTION notices may result in minor to moderate injury  damage to  equipment or property  and void the warranty        Model  GVH C  GVH F Installation    Location      DO NOT MODIFY OR ALTER THIS EQUIPMENT  OR ADD ATTACHMENTS OF ANY KIND     NOTE      For some installations  it may be necessary to con
42. ow hood to thoroughly dry or wipe dry with clean dry cloth   Z Clean filters as needed and replace          Restore supply power to hood        5 03  Fire Suppression System Mlaintenance    The fire extinguishing system should be maintained as outlined in the Standard for Wet Chemical  Extinguishing Systems           17A and in accordance with the instructions of the system s installer     Please contact a local Authorized Fire Protection Company or Agent for all system maintenance  necessary  troubleshooting and or repairs     General Maintenance of the fire suppression system is very important  Inspection and servicing is to be  performed by qualified fire protection professionals  Required maintenance activities are described in the  subsequent sub sections     Consult the Fire Suppression System documentation provided by the system installer for complete  maintenance guidelines     42    Hood Cleaning  amp  Maintenance Model  GVH C  GVH F       5 03 1  Semi Annual Fire Suppression System Mlaintenance       servicing and inspection of the fire suppression system must be performed by qualified and certified Fire  Protection Equipment specialists  As a minimum  field inspection of the Fire Suppression System must be  conducted semi annually  Such maintenance shall consist of the following     1  Confirm that the fire hazard potential has not changed     2  Inspect suppressant storage tank for fill level and charge pressure  Inspect and test release  mechanism     3  Check al
43. perty  and void the warranty     Power Rating for Hood  amp  Appliance   on Same 208 240V Circuit    Branch Circuit Protector  Field Provided Appliance Hood Power  Amps  if Connecting  Power  Amps   Amps  Hood  amp  Appliance on  Same Circuit    Voltage Hz Phase    208 240 O   10 5   10 6   14 5  14 6   22 5  22 6   39 5  38 6   46 5  46 7   50                                        Appliance s  exceeding 50 Amps must have a separate circuit from the Hood  but intelocked through the  Hood contactor coil        Appliance provided and rated separately from Hood     Power Rating for Hood Only  if Appliance is on Separate Circuit  amp  Interlocked  Through Separate Contactor    Voltage Hz Phase          Breaker   Amps        11    Model  GVH C  GVH F Installation       2 04 1  Electrical Connections      All electrical installation should be performed by a qualified electrician or technician        mproper installation or poor work practices could result in serious injury or even death  damage to  equipment or property  and void the warranty        1  Install appropriate circuit breaker in Main breaker box   2  Remove rear Hood Cover and Back Skirt Panel     3  Connect appropriately sized wire  supplied by customer  from breaker box to Hood  Allow sufficient  cord length to allow moving hood  if necessary for future service or maintenance     4  Connect Hood and Appliance wiring to Hood terminal blocks  Several different wiring configuration  options are possible depending on spe
44. perty damage  and void the warranty     e   DO NOT use or store flammable liquids or materials that produce flammable vapors in the vicinity of  this or any other appliance        Consult a qualified electrician to ensure that all electrical requirements are met and that the unit is prop   erly grounded     9 Before installing or servicing this equipment  read the contents of this manual thoroughly        Improper installation  adjustments or alterations  or improper service maintenance could result in seri   ous injury or even death  damage to equipment or property  and void the warranty        Failure to comply with these WARNING notices could result in serious injury or even death  and equip   ment or property damage          WARNING  UV MODEL ONLY       An internal ultraviolet radiation source is present on these models during operation        Keep protective covers and panels in place during normal operation  Replace any removed after servic   Ing        An interlock circuit in the hood reduces potential for exposure to excessive ultraviolet radiation  DO  NOT attempt to disconnect or bypass this interlock        Looking directly at a UV light source without proper eye protection can cause serious eye injury        vi    Safety Model  GVH C  GVH F    e Maintain a minimum clearance of 18   4572mm  between the hood s exhaust outlet and the ceiling  or  other overhead obstruction        Exercise care when lifting or moving the unit  See Section 1 4 4  Hood Weights        Ex
45. r System    The GVH Hood Filter System consist of three  3  stages  This section describes filter maintenance and  cleaning procedures necessary to keep the air cleaning system at peak performance        4 02 1  Ventless Hood Filter Table    Filter      2 How to remove How to clean How to install    Baffle Filter Clean daily Section 4 02 02  Section 4 03 01  Section 4 02 03        EAC Filter Clean daily Section 4 02 02  section 4 03 02  section 4 02 03        Never clean  Section 4 02 02  Replace Onl Section 4 02 03   Section 4 03 03     Replace every 30    Charcoal Filter  days       Ultra violet Lamp   Clean every 30 days   if equipped  Replace annually    Section 4 03 04                   32    Operation  amp  Filter Maintenance Model  GVH C  GVH F          4 02 2  Filter Removal   Baffle  EAC  amp  Charcoal          2 Remove Filter Access Door    1 Place in OFF position              3      remove  simply slide the  desired Filter straight out of  its Filter Chamber track     33    Model  GVH C  GVH F Operation  amp  Filter Maintenance        4 02 3  Filter Installation   Baffle  EAC  amp  Charcoal             Z       To reinstall Filters  align with the  filter channel and slide straight in  until filter hits a stop     Note airflow direction arrows  on filters when reinstalling     Heinstall Access Door    4 02 4  Charcoal or Baffle Filter Missing       If the Baffle or Charcoal Filter is missing  or not positioned correctly   the Charcoal or Baffle Filter Missing light 
46. sult a HVAC specialist to    confirm that proper room air exchange is occurring and that the on site A C  system is capable of handling the anticipated heat load        Exhaust ventilation is recommended for areas in which recirculating hoods are operated  Giles  recommends 50        per linear foot of hood space  This amount could vary based on local codes  and site specific situations     NOTE   9  he sound level of the hood while operating will be approximately 65 dB        1  Do not obstruct the exhaust air outlet  Maintain a minimum clearance of 18 inches  457 2 mm   between the air outlet and the ceiling  or any other overhead obstruction     2         GVH C Hood model is designed to sit atop a counter space  Ensure that the intended site is  structurally sound and capable of supporting the hood s weight plus that of the appliance s  to be  placed under it  See Section 1 4 4  Hood Weight     3  If installing a GVH F Floor Stand model  ensure that the floor space is fairly level  The hood stand  features adjustable legs to accomplish final leveling of the unit     Installation Model  GVH C  GVH F       2 02 1 Clearance to Combustibles  GVH C Model          18  CLEARANCE  TO COMBUSTIBLES    18 MIN  EXHAUST CLEARANCE ao 56 1 4                  20 7 8 DOOR SWING           ET    34 5 16                               30 1 2 INSIDE                         99 11 16                         32  0 wt m 0  CLEARANCE RIGHT    TO COMBUSTIBLES TO COMBUSTIBLES    0  CLEARANCE  TO COMBU
47. uous  tone alarm should sound as the exhaust is covered  the red Baffle or Charcoal Filter Clogged light  should illuminate and the Appliance Powered light should turn OFF  The appliance should also turn  OFF during this time  Remove the obstruction  the alarm should silence and power should be  restored to the appliance  If the alarm tone does not sound  fails to silence  or the appliance fails to  turn OFF or turn ON  contact a service agent to have the Clogged Filter interlock checked     41    Model  GVH C  GVH F Hood Cleaning  amp  Maintenance       5 02  Quarterly Hood Cleaning    DO NOT wash down hood with water from a spray hose    DO NOT steam clean or use any type pressure washer    DO NOT use products containing chlorine or other caustic chemicals   DO NOT use abrasive products  steel wool or scouring pads        To maintain effectiveness and performance  the hood must be cleaned  at a minimum  every 3 months   1  Disconnect power to the unit  preferably at a breaker    2   f possible  disconnect and remove the under hood appliance    3  Remove all filters from the hood   4    Using a soft cloth  sponge  or towel and a mild bio degradable degreaser  clean the entire hood  plenum and blower section to remove grease film accumulation from interior surfaces  Inspect the  hood fan and clean any grease build up from the fan blades     5  Thorough clean the under hood area and all exterior surfaces with mild degreaser or a good quality  stainless steel cleaner     6  All
48. urned on     2 Baffle Filter Check  Place power switch in the OFF position  open Access Door and remove the  Baffle Filter  Close door and turn power ON  The red Baffle or Charcoal Filter Missing light  should illuminate and the Appliance Powered light should be OFF  Check the underhood  appliance to ensure that it cannot be turned on  Turn power OFF and reinstall the Baffle Filter     3  EAC Filter Check  Place power switch in the OFF position  open Access Door and remove the EAC  Filter  Close door and turn power ON  All three EAC status LED s should illuminate and after  approximately 2 minutes  an intermittent tone  beeping  alarm should sound  The Appliance  Powered light should turn OFF  Check the under hood appliance to ensure that it cannot be turned  on  Turn power switch OFF and reinstall EAC Filter     4  Charcoal Filter Check  Place power switch in the OFF position  open Access Door and remove the  Charcoal Filter  Close door and turn power ON  The red Baffle or Charcoal Filter Missing light  should illuminate and the Appliance Powered light should be OFF  Check the underhood  appliance to ensure that it cannot be turned on  Turn power OFF and reinstall the Charcoal Filter     b  Filter Clogged Check  Perform this check ONLY after installing a new Charcoal Filter  The easiest  method for checking the clogged filter interlock is to completely cover the hood s exhaust outlet    with piece of cardboard while the hood is running and the appliance power is ON  A contin
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
COBVIEW PRINT SUITE - Tools for COBOL Programmers  Infocus Replacement Lamp for, IN3124, IN3126, IN3128HD  OS Upgrade - SDE Systeme GmbH  発行日 2005年7月 次回発行 2006年7月 1-0507/5000/MS/MP S I I グ  Fujitsu LIFEBOOK A531    RouterBOARD 411AR Quick Setup Guide and Warranty Information  Fireboss Parts Manual  OrangeRx R620 6CHs DSM2+S.BUS Receiver Manual Brief    Copyright © All rights reserved. 