1. lt xi Ajddns 1 19 219 C U04 312044X3 4 MA 8 l 8 3 04d Hn yuh 2 jul yu 86un8a24p3 VOI A0EC UPN P 4 BELIMO Damper actuator for operating air control dampers in ventilation and air conditioning systems for building services installations For air control dampers up to approx 1 m Torque 5 Nm Nominal voltage 100 240 V Control Open close or 3 point Technical data Electrical data Functional data Safety Dimensions Weight Safety notes A Technical data sheet Damper actuator LM230A Nominal voltage AC 100 240 V 50 60 Hz Nominal voltage range AC 85 265 V Power consumption In operation 1 5 W nominal torque At rest 0 4W For wire sizing 4VA Connection Cable 1 m 3 x 0 75 mm Torque nominal torque Min 5 Nm 9 nominal voltage Direction of rotation Reversible with switch 0 or I Manual override Gearing latch disengaged with pushbutton self resetting Angle of rotation 9541 limited on both sides by means of adjustable mechanical end stops Running time 150 5 Sound power level Max 35 dB A Position indication Mechanical pluggable Protection class Il Totally insulated Degree of protection IP54 in any mounting position EMC Low voltage directiv
2. Electricity connection 1x230 V 10 A Dimensions HBD 1900 870 620 mm Fans Centrifugal back curved blades with overheating protection Capacity 750 m h Supply air filter EU 6 bag Extract air filter EU 3 bag Fire class A15 Air duct connections Y 200 mm Weight 180 kg Colour White REC TemoVex AB Ventilation unit RT 700S Operation and service manual Reservation for eventually constructionchanges Date 2010 02 19 Rev 05 Fil RT 700S XT eng p65 REC TemoVex AB Operation Fans The unit is started with the start button 51 The electric panel contains a transformer with connec tionsforfive connected voltages The two five steps switches S2 S3 make it possible operating with 5 different air flows voltages for each fan The fan motors has built in overheating protections which are activated at a too high temperature in the motor winding An overheated motor is reseted automatically as the motor is cooled off If this is repeated often the fans should be checked by an authorized service technician If both the fans stops the power to the ventilation aggregate must be checked as well as the automatic fuse F1 behind the electric panel After heater If the temperature in the after heater is to high around 90 C the overheating protection will trigger With the switch for operation stop you can switch off the power to the ventilation aggregate After 3 minutes the overheating protect
3. 31 675500 Telefax Facsimile no 46 42 202238 f rs krar harmed att produkt herewith declares that the product materialslag type of equipment Ventilationsvirmevixlare Air to air heat exchangers for ventilation modell typ model type RT 700S verensst mmer med best mmelserna i f ljande EG direktiv is in conformity with the provisions of the following EC directives 73 23 EEG L gsp nningsdirektivet L VD Low Voltage 93 68 EEG directive LVD 89 392 EEG Maskindirektivet MD Machinery directive 91 368 EEG 93 44 EEG 93 68 EEG 89 336 EEG Direktivet f r elektromagnetisk kompatibilitet EMC 92 31 EEG Electromagnetic Compatibility EMC directive 93 68 EEG Helsingborg 2005 07 01 Lennart Skoglund Verkst llande Direkt r Managing Director
4. 110 V LM72A A AC 100 240 V A AC 24 V DC 24 V DC 48 110 V LM72A SR A AC 100 240 V A P 4 BELIMO 1 N Lt BERE ot y 2 3 ont Ea psa 0 X 1 LU n n EE O 2 E 5 1 2 3 1 2 3 51 S2 S3 C b C J del Y LM24A LMC24A LM24A S TMC24A S LM72A TMC24A L1 LI gt LM24AP5 I d 2 3 2 z r m r e Bey 51 S2 53 51 52 53 L4 0 N 1 q LM230A LMC230A LM230A S TMC230 S TMC230A Y lt DC 0 10V D D el el FIN GS LL 1 S1 S2 S3 Ji 0 Y 44 DC 0 10V 17 m U gt DC 2 10V 17 Up Tr ET 12 3 5 12 3 5 LM24A SR LMC24A SR LM24A MP LM24A MF TMC24A SR Y 4 DC0 10V N Li 1 Us _ DC 2 10 V AC 24 V DC 24 V r4 LM24A V VR 12 1235 5 Ep LM72A SR Y lt DC0 10V NU 1 r Us DC 2 10 V L NE 1 2 1235 db LM230ASR LM24A V LM230A V VR www belimo com ma REC TEMOVEX EG FORSAKRAN OM OVERENSSTAMMELSE EC EEA DECLARATION OF CONFORMITY Undertecknad representerande f ljande tillverkare The undersigned representing the following manufacturer Namn Name REC Temovex AB Adress Address Fornminnesgatan 11 Telefon Telephone no 46
5. 2 Active by pass is indicated by the LED 2 thermometer symbol above Note It s important that the ventilation aggregates temperature adjustment is adjusted to the premises heating system From a general point of view the maximum supply air from the aggregate shall be set higher than the temperature of the house i e the temperature setpoint adjustment of the heating system of the house This to avoid the systems to intefeer with each other Example Minimum supply of air temerature 18 Maximum supply air temperature 22C Temperature of the heating system of the house 20C Date 2010 02 19 Rev 05 Fil RT 700S XT eng p65 REC TemoVex AB Maintenance Changing of filter The exhaust air filter bag shall be changed 2 3 times a year Note If the filter is not changed over pressure is created in the house In the long run this can give moisture damages to the house The outdoor air filter has to be changed at least twice a year The filters are changed by pulling them out of their holder and replace with new Both filters can be ordered from REC Temovex Order numbers are article nr 487 1 extract and 4872 supply Cleaning the fans Switch off the power Loosen the screw on the electrical connector to each fan and disconnect the fans The fans can now be pulled out for cleaning Clean with a soft brush Re mount in reversed order Condensation pipe The water pipe and hose for condensate shall be co
6. EC TemoVex AB Ventilation unit RT 700S Operation and service manual Reservation for eventually constructionchanges Ventilation unit RT 700S Supply air to bedrooms living room etc the house 400 Exhaust air leaving the house kitchen etc Start up and adjustments When the ventilation unit is installed the aggregate should be inspected and adjusted preferable by a qualified installation technician 1 Control that the fans are effected by the speed switches 2 Control that air ducts and details are correctly installed and the condensate hose is connected draining to the sewer system In some cases no condansate is formed i e low humidity favourable temperature profiles why the connection can be left out 3 Control that supply air blows out from all room air inlets and all the exhaust air outlets removes air 4 Adjustthe ventilation system according to the given values stated on the ventilation drawing The airflows can be adjusted in 5 steps individually for each fan The exhaust air flow shall be 1096 higher than the supply air flow to create a moderate under pressure in the premises 5 Adjustthe wanted temperature setpoint for the after heater and by pass function see operation Date 2010 02 19 Rev 05 Fil RT 700S XT eng p65 Out door air entering REC TemoVex AB Ventilation unit RT 700S Component list RT 700S model with afterheater and by pass function electroni
7. REC TemoVex AB KI REC removex REC TemoVex HT 700S Operation and service manual Ventilation unit RT 700S Easy operation Environmentally frendly Low power consumption Low noiselevel Va Effective heat recovery REC TemoVex AB Fornminnesgatan 11 253 68 Helsingborg info rec indovent se 2 www rec indovent se 46 31 675500 REC TemoVex AB Ventilation unit RT 700S Operation and service manual Date 2010 02 19 Reservation for eventually constructionchanges ev 0 Fil RT 700S XT eng p65 1 REC TemoVex AB Ventilation unit RT 700S Index Productinformation 34 Operation 5 Maintenance 6 Receiving andinstallation 7 Componentlist 8 Attachements Electrical wiring diagram Belimo throttle motor CE confirmation REC TemoVex AB Ventilation unit RT 700S Operation and service manual Date 2010 02 19 Reservation for eventually constructionchanges Rev 05 Fil RT 700S XT eng p65 REC TemoVex AB Product information Description The REC TemoVex RT 700S model is designed for effective ventilation of private houses offices nurser ies and other premises The unit contains a counterflow heat exchanger with heat recovery efficiency of gt 80 The aggregate consists of body heat exchanger in aluminium two fans by pass throttle valves and electrical control equipment REC TemoVex counterflow heat exchanger has completely separate
8. c thermostat Position FF TF EVB ST1 ST2 GTI TG GT2 SK T2 C1 F1 Ti 53 54 51 52 55 X1 Extract air filter Supply air filter No Description Extract air fan Supply air fan Afterheater By pass actuator motor Temperature probe Electronic thermostat Overheating thermostat Electronic relay Transformer Capacitor Automatic fuse Autotransformer Rocker switch 5 step change over switch On off switch Plinth socket Extract air filter Supply air filter REC TemoVex AB Ventilation unit RT 700S Operation and service manual Reservation for eventually constructionchanges Make Ziehl Ziehl Veab Belimo DiXell DiXell Kienzler Crouset Brugnera Ziehl Chiri PTF L bcke General Dreefs Comprim Type RZE 250 AS47 10 155W 0 7 A 230V RZE 250 AS47 10 155W 0 7 A 230V 900W 230V LM230F PTC S6S 1000 Ohm XT120C PTC panel 12VAC Type KW 94 200 250V 16A 80 GN84137111 50 600V 25A 153 M 230 12V 5 uf 400V 250V 4AT RA 131 27893 1 5 volt outp 70 90 110 130 150 170 190V 1834 6 4 250V A6CH 230V 10A 2 pol with indicator REC Temovex 4871 filter class EU3 REC Temovex 4872 filter class EU6 Date 2010 02 19 Rev 05 8 Fil RT 700S XT eng p65 E1001 S00 13 938 T_T IS es poso vaxa OO o o Lu x les AS eXxjgl 1 TUNA 42398 43339 Aiddns 42943X3
9. d airflows which prevents leakage between incoming outdoor air and exhaust air leaving the house The aggregate is designed for 750 m3 h maximum airflow at normal available pressure drop Heat exchanger The heat exchanger is built up by thin corrugated alu minium sheets which form ducts where exhaust air is completely separated from the supply air The heat is transfered throughthe sheets Cover Hot dipped galvanised metal with insulation in between White coated front and gables The front door makes service easy The cupboard is equipped with adjustable feet Exhaust air Supply air Fans The two fans consists of backward curved fan wheel blades This gives low energy consumtion high fan efficiency combined with lower noise levels The fans are of plug in type The air flows can be adjusted in 5 steps individual for each fan If the fans are overheated the fans overheating protection is triggered The power to the fans is switched off and the fans stop Restart will be done automatically after cooling of Filter The unit is equipped with outdoor air filter and exhaust air filter The outdoor air filter filters the incoming air to the house The filter has filter class EUG The exhaust air filter protects the unit fans and heat exchanger from fouling The filter has filter class EU3 REC TemoVex AB Ventilation unit RT 700S Operation and service manual Reservation for eventually constructionchanges Vent
10. e CE according to 89 336 EEC CE according to 73 23 EEC Mode of operation Type 1 to EN 60730 1 Ambient temperature range 30 50 C Non operating temperature 40 80 C Ambient humidity range 95 r H non condensating EN 60730 1 Maintenance Maintenance free Dimensions See Dimensions on page 2 Weight Approx 500 g The damper actuator is not allowed to be used outside the specified field of application especially not in aircraft or any other form of air transport Caution Power supply voltage Assembly must be carried out by trained personnel Any legal regulations or regulations issued by authorities must be observed during assembly The device may only be opened at the manufacturer s site It does not contain any parts that can be replaced or repaired by the user The cable must not be removed from the device When calculating the required torque the specifications supplied by the damper manufacturers cross section design installation site and the air flow conditions must be observed The device contains electrical and electronic components and is not allowed to be disposed of as household refuse All locally valid regulations and requirements must be observed P d Open close damper actuator AC 230 V 5 Nm BELI MO Product features Simple direct mounting Simple direct mounting on the damper spindle with a universal spindle clamp supplied with an ant
11. i rotation strap to prevent the actuator from rotating Manual override Manual operation is possible with the self resetting pushbutton the gearing latch remains disengaged as long as the pushbutton is pressed Adjustable angle of rotation Adjustable angle of rotation with mechanical end stops High functional reliability The actuator is overload proof requires no limit switches and automatically stops when the end stop is reached Accessories Description Data sheet Electrical accessories Auxiliary switch S A T2 S A Feedback potentiometer P A 2 P A Mechanical accessories Shaft extension AV6 20 T2 ZLM A Electrical installation Wiring diagrams _ Open close control 3 point control Note A N Lt N L1 Caution Power supply voltage Other actuators can be connected in parallel Please note the performance data Direction of rotation 1 Dimensions mm Dimensional drawings 66 Damper spindle Length OTO Aaa min 37 6 20 94 Data sheet T2 LM230A en v1 3 04 2005 Subject to modifications LM A TM A 9 10000 v 1204 www belimo com LM A TM A AC 24 V DC 24 V DC 48
12. ilation unit RT 700S Electric equipment The electric equipment consists of Connection cable with grounded plug Two fan motors with built in overheating protection and belonging capacitors Electric panel with two five step switches for airflow switch for operation stop and electronic thermostat to control the automatic by pass function and the after heating 1 XI Exhaust air filter Supply air filter Supply air fan Exhaust air fan Throttle actuator ST1 Throttle actuator ST2 El Inspection shutter Date 2010 02 19 Rev 05 3 Fil RT 700S XT eng p65 REC TemoVex AB Ventilation unit RT 700S Function diagram i rc SI 52 s3 84 35 Q STI Exhaust air GTD ADP r H XCH TF EVB Room tdoor Extract Dutdoor ai gt E Extract air E E se FF it RT700S H XCH Heat exchanger counter flow S5 Power on off TF Supply air fan S1 Speed switch supply air fan FF Extract air fan S2 Speed switch extract air fan TC Temperature controller S4 Heater Auto off GT1 Temperature probe ST1 ST2 By Pass damper motors S3 Max flow switch EVB After heater Other technical data Electric heater 1 8 kW with overheating protection and automatic by pass function from electronic thermostat
13. ion is automatically reseted The overheating can be caused by a clogged up supply air filter a fault in the electronic thermostat etc Manual and automatic by pass A high indoor temperature can be lowered if by passing the heat recovery unit letting the colder out door air into the room This is easily done by activating the by pass function The two by pass dampers are automatically controlled by the electronic thermostat on the control panel REC TemoVex AB Ventilation unit RT 700S Operation and service manual Reservation for eventually constructionchanges Ventilation unit RT 700S Min supply air temperature The actual measured temperature is normally shown in the display Press and keep SET 1pressed to select minimum supply airtemperature setpoint The selected setpoint is showned flashing LED The setpoint can be adjusted up and down with the arrow buttons Confirm selected setpoint by pressing SET 1 shortly or wait 10s The selected setpoint can be checked easily by shortly press SET 1 Active afterheating is indicated by the LED 1 thermometer symbol above Max supply air temperature Press and keep SET 2 pressed to select maximum supply airtemperature setpoint The selected setpoint is showned flashing LED The setpoint can be adjusted up and down with the arrow buttons Confirm selected setpoint by pressing SET 2 shortly or wait 10s The selected setpoint can be checked easily by shortly press SET
14. ntrolled every yearto avoid the outflow from becoming clogged up REC TemoVex AB Ventilation unit RT 700S Operation and service manual Reservation for eventually constructionchanges Ventilation unit RT 700S Cleaning the heat exchanger Cleaning of the heatexchanger package is normally not needed if the unit maintenance change of filters etc has been carried out regulary Cleaning the heat exchanger Switch off power to the unit Open the door unscrew the covering sheet and the cleaning shutter located at the very bottom of the closet Take out the plastic plug Dismount the exhaust and the supply air fans by loosing the electrical connections and pull the fans out Spray the heatexchanger parts with a mild de tergent rinse carefully with water The water will drain out through the condensate drainage hose Never use high pH cleaners containing for example ammonia or caustic in combination with aluminium heat exchanger package Control panel EE li TIL Exhaust air filter Supply air filter Supply air fan Exhaust air fan Throttle actuator ST1 Throttle actuator ST2 Inspection shutter Date 2010 02 19 Rev 05 6 Fil RT 700S XT eng p65 REC TemoVex AB Receiving and installation Receiving control Control that the number of parcels agrees with the ordered and that the goods isn t damaged by the transport If any transport damages please contact the transport compa
15. ny immediately Store the goods indoors Installation The unit is intended for installation in a heated place such as laundry corridor workroom storage room or similar There must be possibility for connection to a ceespool sink etc connected to the sewer system Air ducts shall be connected on top of the aggregate advisably with flexible hose silencers Normally supply and exhaust air ducts which is installed in a warm place does not have to be insulated Extract and outdoor air ducts shall be insulated to avoid condensation on the ducting Supply and exhaust air ducts located in cold areas shall be insulated with minimum 150 mm insulation Thefrontofthe aggregate should be easily accessible The aggregate has in the bottom a 3 4 condensation drain for connection to the sewer system or a collecting vessel optional The condense drain is needed as condensate can be produced ifthe exhaustair contains a lot of moisture Ifthe condensate pipe is located in a cold place the pipe must be well insulated The aggregate is adjusted in height and sideways with adjustable rubber feet The unit should be connected to a earth grounded wall socket 230V 10A The electronic thermostats temperature probe markt GT1 is normally placed in the extract air duct to control the room temperature Toinstead control the minimum supply inlet tempera ture the probe should be placed in the supply air duct some distance from the outlet R