Home

PEMED - Production Engineering Medical Equipment Division

image

Contents

1. half or full wash increase decrease or stop pump speed manual processing special functions unit is on wheels collapses to approximately 24 x 24 x 30 high tube for storage when not in use Shipping weight is about 200 Ibs Blood bank plasma defroster 1 750 List 7 280 MedCon EX Blood banking and plasma bags defroster unit is used to safely thaw frozen blood after removal from ultralow freezer and before infusion into 4 patient Features automatic operation rockers hold up to three bags at once built in temperature sensors detects frozen bags unit stops when bags are defrosted so blood is never overheated With owners manual as shown Shipping weight is about 125 pounds file C web bloodbank bloodbank htm 9 12 9 15 2014 PEMED Blood Bank and Collection Cell washing system 1 475 each List 8 700 each MedCon EX Haemonetics model 115 cell washing system New in 1991 appear to have little use Ruggedized for temperature range of 40 degrees Centigrade to 75 degrees Centigrade and may be stored in those conditions as long as fluids are drained This unit is a continuous gravity flow blood cell washing system It is for washing previously frozen red blood cells This process is sometimes called deglycerolization usually by a sequential dilution protocol After thawing the red cells are first diluted with 12 sodium chloride then twice with 0 9 sodium chloride 0 2 glucose using
2. 000 rpm 51 070 rcf depending on rotor 20 to 40 C operating range speed and time setting dials time to 120 minutes plus hold analog temperature and speed gauges automatic preprogrammed braking and acceleration may be used with other rotors such as GSA GS 3 and HS 4 Overall dimensions of the unit e width 30 in e depth 36 25 e height 46 5 Shipping weight is about 700 pounds Large capacity refrigerated centrifuge 6 975 List 33 400 MedCon VG Sorvall RC 3C Plus refrigerated centrifuge 208 V 60 Hz 1 phase Features e centrifuge rolls on casters and locks to floor with screw out stabilizers e 23 inch diameter chamber e H6000A HBB6 shielded swinging bucket rotor rated at 5 000 rpm 7280 rcf e six buckets 98 mm ID with 92 mm inserts 1 L capacity per bucket file C web bloodbank bloodbank htm 2 12 9 15 2014 PEMED Blood Bank and Collection centrifuge has a maximum operating speed of 6 000 rpm with fixed angle rotors such as the SS 34 dial in temperature speed and time settings and digital display of actual hold time mode rotor code prevents improper usage 20 to 40 C operating range fan cooled motor door interlock ARC automatic rate control for gradual acceleration rpm rcf display toggle program key allows access to ten stored memory functions tachometer port 3 wire power cord to fit Hubbell receptacle diagnostics indicator lights panel Service Manual included Overall
3. dimensions of the unit e width 30 25 in e depth 40 e height 45 5 Shipping weight is about 700 pounds Dielectric sealer 750 ey List 2 300 MedCon VG Fenwal Hematron model H 1 dielectric TUBE sealer 115 EV 50 60 Hz Features e power on off toggle back of unit e thermostat adjusts back of unit e carrying handle Overall dimensions of the unit e width 12 5 in e depth 11 e height 10 25 Shipping weight is about 25 pounds Platelet concentrating system 2 750 ist 16 700 MedCon VG Harvest SmartPReP platelet concentrating system 115 V 50 60 Hz eatures file C web bloodbank bloodbank htm 3 12 9 15 2014 PEMED Blood Bank and Collection centrifugation system to concentrate autologous platelets for injection to potentiate healing at wound sites increased platelet yields with less activation as compared to a general purpose centrifuge centrifuge and cart with top supplies tray and four locking casters e to be used with SmartPRep procedure pack syringes cups anticoagulant cannula etc Overall dimensions of the unit e width 15 in e depth 18 e height 39 Shipping weight is about 110 pounds Also available without stand Features Baylor system rolling unit with locking casters rear transport handle reservoir holder and IV pole with four bag hooks peristaltic pump lighted rotor chamber LCD message display window with touchpad response buttons power on off Rock
4. the mixing platform for adequate mixing Features e wired for 115 230 VAC 50 60 Hz so may be used anywhere in the world under most any conditions occupies a minimum of floor space 2 1 2 sq ft designed for heavy clinical service not sensitive to climate extremes centrifuge on off button centrifuge spins at about 5800 rpm built in mixing tray which supports unit of blood to be washed mixer control buttons oscillates at about 180 cycles per minute minute timer 0 30 minutes built in IV pole uses disposable centrifuge and tubing not included with system with both operator and service manuals The manufacturers s web site may be seen at http www haemonetics com Several products come from plasma collection and processing including albumin and plasma protein fractions used as volume expanders for burn and shock victims gamma globulins used for prevention of as tetanus rabies measles and other diseases blood grouping sera test kit controls and quality control reagents Shipping weight is about 100 pounds for the units and 50 pounds for the stands 4 units in stock Blood reprocessing unit 3 250 each List 27 300 MedCon EX Haemonetics cell saver 3 plus This unit reprocesses blood from a blood file C web bloodbank bloodbank htm 10 12 9 15 2014 PEMED Blood Bank and Collection donor patient or other source and separates it into blood cells and plasma Unit also removes clotting agent from plasma In
5. this manner blood may be prepared for long term storage or maybe re infused back into a patient during surgery reducing the need for blood from donors Also called an auto transfusion machine ATEN Peron Seen tme t 2 rere Uses disposable centrifuges for continuous separation Shipping weight is about 150 pounds 2 units in stock Also have 1 cell saver 3 2 750 Also have a cell saver 4 3 750 Blood recovery reprocessing system 1 275 List 11 200 MedCon VG Haemonetics model 30S blood recovery system Salvages blood shed before during or after surgery Recovers patient s own blood so that it may be reinfused to him or her This reduces or eliminates the need for banked blood Salvages shed blood suctioned from a surgical wound in the OR and from drainage tubes during recovery Uses disposable single use plastic tubing set and a spinning centrifuge bowl chamber where red cells are separated from other components and washed The manufacturers s web site may be seen at http www haemonetics com Shipping weight is about 225 pounds Copyright 1993 2014 by Production Engineering PEMED is a registered trademark of Production Engineering MedCon is also a trademark of Production Engineering All rights reserved Contact PEMED for license requests The usual copyright notices and disclaimers Except for search engines or file C web bloodbank bloodbank htm 11 12 9 15 2014 PEMED Blood Bank and Col
6. 9 15 2014 PEMED Blood Bank and Collection PEMED Production Engineering Medical Equipment Division PEMED HOME 6035 E 38th Avenue Denver Colorado 80207 USA 303 393 7800 FAX 303 393 1482 Blood bank and collection To get this entire section as a printable PDF document click here Please note Blood bank refrigerators freezers and ultra low freezers are shown under the laboratory equipment refrigerators section Phlebotomy chair 275 chair integrated with metal frame supporting drawer and arm rests e chair seat is 17 5 inches wide with vinyl upholstery e left and right padded arm rest supports 16 x 7 inches adjustable height e 10 5 x 14 5 x 3 inch drawer for supplies Overall dimensions of the unit e width 42 in e depth 17 5 e height 37 Shipping weight is about 70 pounds Blood products bag sealer 675 List 2 200 MedCon VG Cobe BCT Seal Safe System part no 957000 000 Has activating grip for dielectric sealer and 4 pin connector to Cobe Spectra Aphaeresis System Overall dimensions of the unit e width 7 5 in file C web bloodbank bloodbank htm 1 12 9 15 2014 PEMED Blood Bank and Collection e depth 10 e height 2 Shipping weight is about 4 pounds High speed centrifuge 4 975 List 23 400 MedCon VG Sorvall RC 5B superspeed refrigerated centrifuge 208 V 60 Hz 1 phase Features 16 inch diameter chamber SS 34 fixed angle rotor max speed of 21
7. er switch 10 foot heavy duty power cord with hospital grade plug cord wrap vinyl storage cover Overall dimensions of the unit e width 18 in e depth 31 5 e height 57 Shipping weight is about 250 pounds Autologous blood recovery system 3 750 each file C web bloodbank bloodbank htm 4 12 9 15 2014 PEMED Blood Bank and Collection List 45 900 MedCon VG Cobe Brat 2 Autologous blood salvage system 115 V 60 Hz Features top loading peristaltic pump color coded cycle dial on left side dedicated processing keys for quick starts lighted centrifuge compartment with flat clear view lid uses the Baylor bowl rear transport handle rolls on 4 casters power on off rocker switch 11 5 foot power cord with hospital grade plug unit pictured has 6645 hr second unit has a use age of 5578 hr Overall dimensions of the unit e width 20 in e depth 23 e height 48 5 56 to iv pole Shipping weight is about 200 pounds 2 units in stock Blood reprocessing autotransfusion unit 2 750 each List 55 600 MedCon VG Dideco Compact A autotransfusion cell saver model 75170 110 V 60 Hz nit salvages red blood cells for example during surgery or for blood donation Features touchpad controls for program access setting volumes etc LED display indicates active cycle flow volume and centrifugal speed lighted centrifuge compartment container holder and 3 hangers large 12 inch rea
8. ion Shipping weight is about 250 pounds 2 units in stock Blood re processor auto transfusion manual 1 750 List 17 750 MedCon EX Haemonetics cell saver plus This unit reprocesses blood from a blood donor patient or other source and separates it into blood cells and plasma Unit also removes clotting agent from plasma In this manner blood may be prepared for long term storage or maybe re infused back into a patient during surgery reducing the need for blood from donors Also called an auto transfusion machine Uses disposable centrifuges for continuous separation Features flip down side tray built in IV pole locking castors transport handles cord wrap attached setup guide wired for 100 120 VAC 50 60 Hz so may be adapted for international use Dimensions e width 18 5 inches e depth 23 inches e height 44 inches This is a manually operated machine Shipping weight is about 250 pounds Blood re processor auto transfusion manual or automatic 2 750 each file C web bloodbank bloodbank htm 7 12 9 15 2014 PEMED Blood Bank and Collection List 32 750 MedCon EX Haemonetics cell saver 4 This unit reprocesses blood from a blood donor patient or other source and separates it into blood cells and plasma Unit also removes clotting agent from plasma In this manner blood may be prepared for long term storage or maybe re infused back into a patient during surgery reducing the need fo
9. lection link listing no part of this website including derived information may be republished without express written permission and payment of fees Production Engineering Medical Equipment Division 6035 E 38th Avenue Denver Colorado 80207 USA 303 393 7800 FAX 303 393 1482 file C web bloodbank bloodbank htm 12 12
10. r blood from donors Also called an auto transfusion machine Uses disposable centrifuges for continuous separation Features IV pole cord wrap transport handle locking castors digital display and controls wired for 100 120 V AC 50 60 Hz so may be adapted for international use anywhere in the world may be run in either manual or automatic mode Dimensions e width 17 inches e depth 29 inches e height 53 inches Shipping weight is about 250 pounds 2 units in stock Blood reprocessor 3 750 List 14 700 MedCon EX Haemonetics blood recovery and reprocessing system Used to recycle blood from surgical procedures for use back to patient Salvages blood shed before during or after surgery Recovers patient s own blood so that it may be re infused to him or her This reduces or eliminates the need for banked blood Salvages shed blood suctioned from a surgical wound in the OR and from drainage tubes during recovery Uses disposable single use plastic tubing set and a spinning centrifuge bowl chamber where red cells are separated from other components and washed file C web bloodbank bloodbank htm 8 12 9 15 2014 PEMED Blood Bank and Collection Features e built in automatic protocols for different surgical procedures for example as shown in photo orthopedic help button start automatic process pause final cycle and stop buttons built in programming menu tubing wash select no
11. r wheels for easy transport transport handle front locking casters file C web bloodbank bloodbank htm 5 12 9 15 2014 PEMED Blood Bank and Collection e 12 5 foot power cord with hospital grade plug cord guard and cord wrap e pushbutton mains on back of unit e alarm Overall dimensions of the unit e width 18 in e depth 22 e height 43 65 to top of pole Shipping weight is about 150 pounds each 2 units in stock Blood re processor auto transfusion automatic 3 250 each List 32 750 MedCon EX Haemonetics cell saver 3 plus This unit reprocesses blood from a blood donor patient or other source and separates it into blood cells and plasma Unit also removes clotting agent from plasma In this manner blood may be prepared for long term storage or maybe re infused back into a patient during surgery reducing the need for blood from donors Also called an auto transfusion machine Uses disposable centrifuges for continuous separation Features flip down side tray built in IV pole locking castors transport handles cord wrap attached setup guide wired for 100 120 VAC 50 60 Hz so may be adapted for international use a fully automatic machine This unit has the same features as found on the cell saver plus but also has a function for automatic protocols on the front panel It is a fully automatic machine file C web bloodbank bloodbank htm 6 12 9 15 2014 PEMED Blood Bank and Collect

Download Pdf Manuals