Contents
1. 3 2 216 ACT Print the active value G for gross N for net T for tare Weight PWT Peak Hold Weight value Weight PWT HEX xx Following number will be MANDATORY ASCII HEX transmitted by value Also Range 00 FF Editor Default 00 use this selection to transmit a NUL as well T Reserved for future use as a token extender EX End of String Notes These tokens can be optionally followed by an ASCII 2 to 9 to specify the number of weight digits including decimal point If no specifier is given it defaults to 6 digits decimal point equivalent to ASCII 6 Further parameter values may be ASCII digits i e range 0 thru 9 or DECIMAL values i e range 0 thru 255 In all cases parameters consume one byte In the term token table parameters are indicated as follows Optional ASCII n Optional Decimal X Mandatory ASCII n Mandatory Decimal X E1070 e tools Software User s Manual 47 Appendix B Mainboard Network LED Diagnostics The network LEDs shown in the photo below are found next to the RJ45 Ethernet connector on the main PC board Below the photo is a table showing what each LED s condition means Appendix C Network Tokens Token Inbound Outbound Inbound Outbound Token Token to net1 from net 1 to net 2 from net 2 decimal value hex value O S X 0 0 Net a T x x Ne x x 7
2. Domain Hame mee oo Sender Address this indicator s e mail address Recipient Address Subject mooo E1070 e tools Software User s Manual 37 EtherNet 2 Modbus TCP Click on EtherNet 2 Modbus TCP in the drop down list to configure a EtherNet 2 Modbus TCP network The window looks like this Net Manage Fieldbus 1 Settings Map Data sir Fieldbus T upe Ethernet 2 Modbus TCP fieldbus IP Address K KEE Gateway b o fo p Subnet b fo fo fo Select Indicator IP Address Key in the IP address for the indicator Gateway Key in the Gateway Subnet Key in the Subnet Click the Map Data tab and the following is displayed This shows the spacing of each piece of data as it will show up on Net Manage Fieldbus 1 Choose to create the D Inbound Data Map or the PLC me Outbound Data Map S by selecting your MET ET choice here NENNEN C Outbound Click here for a L Choose Endian Format S Se pes of L Big or Little here etwork tokens See Appendix C o for full list L ND a o Click here fora SS Big Endian Click here to es drop down list of Trades werd ode trade swap the Data Types Delete Variable Total Bytes 0 word order Data Type Type Data ofBytes Range of Vae se o smao 31 oron This shows the total EE eene ee SE SE FLOAT 6 Float 4 f1O0E toi10E STEE 38 E1070 e tools S
3. Download a NUM CAPS SCRL 8 13 2004 9 47 AM The screen is divided into several parts The command bar has drop down lists for you to choose from when you click on the words The tool bar lets you e start a new file open an existing file e save a file print a file open the Options dialog box upload a configuration file download a configuration file The menu bar contains icons you can click on to show the configuration items for your indicator The configuration window will show the current configuration items to be set The status bar at the bottom of the window shows the status of several keyboard keys and the current date and time Those items needing further explanation are explained in detail in the following sections E1070 e tools Software User s Manual Command Bar File View Tools Help The command bar has the following commands File View Tools Help If you click File the following drop down menu appears File From this list you can eu create a new file IDEN open an existing file lose close an open file Upload Data upload a configuration file from an indicator Download Data download a configuration file to an indicator Save save an open file Save S save an open file under a different name Frink Setup setup the printing or a configuration report Print print a configuration report Recent Files k choose from a list o
4. 100 200 500 1 2 2 5 9 10 10 20 20 50 The fraction choices are for use as dual range divisions The first number is the division size for the first half of the capacity and the second number is the division size for the 2nd half of the capacity All of these capacities function in conjunction with the decimal place position For example if you choose a division size of 5 and a decimal position of 12345 6 your division size will be 5 Pick a decimal position from the drop down list Choices available are 123456 12345 6 1234 56 123 456 12 3456 and 1 23456 Decimal position works with Division size Pick a division size then the decimal position to get the dis played division size Choose if your scale is analog or SensorComm If you choose SensorComm the following appears in the window Weight Source Enable Sensors Bi Be B3 B4 Ghosting You must enable the sensors which will be used by SensorComm You may also enable ghosting which allows the scale to function in certain situations with 1 or more weight sensors out of operation See the Sensor Comm manuals for complete information 12 E1070 e tools Software User s Manual Units Enabled If your new custom unit is larger than one CAL UNIT then you key in how many CAL UNITS make up 1 new custom unit For example 1 TON 2000 pounds so with pounds selected as our CAL UNIT we would key in 2000 for the multiplier one cal unit
5. 250K and 500K Click the Map Data tab and the following is displayed This shows the spacing of each piece of data as it will show up on Net Manage Fieldbus 1 Choose to create the D Inbound Data Map or the PLC RES Outbound Data Map SH by selecting your ML M choice here LL Outbound Click here for a drop down list of BE Choose Endian Format network tokens Big or Little here See Appendix C D f et L or full list T o Enda Ferra Click here for a Big Endian Click here to drop down list of D T Tisde siap word ord trade swap the Data Types Delete Variable Total Bytes 0 word order Data Type Type Data J ofBytes Range of Value This shows the total S8 0 Signeachar 14 et number of bytes used by the indicator This information is required by the PLC programmer and is automatically Unsigned Long 0 to 4 294 967 295 calculated FLOAT 6 Float 4 1 0E to 1 0E 34 E1070 e tools Software User s Manual Click on PROFIBUS in the drop down list to configure a PROFIBUS network The window looks like this PROFIBUS Net Manage Fieldbus 1 Settings Map Data SMTP Fieldbus Type D Valid nodes for PROFIBUS are Profibus fieldbus 0 to 63 Indicator Made Select indicator node If an address greater than 63 is used the CIT will serine in the node for the indicator Acceptable values are 0 to 63 See note at node
6. pa i X H HT HTH HT Cont Xx Jj J x 2 4 0 PLUnumber x x X x 9 PLU Gross Accumulator x Jj J Fx j 247 j 05 PLU Net Accumulator 1 x J x 8 08 PLU Total counter X J J TI 0 PLU Count Accumulator O x J J x 41 0A PLU Tare value x x x x tt B PLULowerTargetweight X x J x x 413 o Recipe Ingredient number x Is ms E Recipe Ingredient target weight x J x w 10 when target is met X X 17 11 Motion Weigher Steady x IIe Te TI Center of Zero zero balance Xx S x 19 B Overload ooo x S D x 2a 1 Undead o o o x Xt j 15 Serial number Do o X P 1 X 2 J 178 Watchdog counter Lo X X 2 J 1 Remotezeo LE 2JJ x 3 26 J 1 Remotetae o LE 1 x 27 J 18 Remote print OX 1 X LL 28 JL 1C Remote accumulate x x aa 1D xe xe xs 20 SE SS SS SS xe S Bridge12 Se xe xm Bridge15 x xm Bridge16 x x indicator Healthy Lo ee x 4 238 Bridge tokens that are inbound to net2 can be outputs for net1 Bridge tokens that are inbound to net1 can be outputs for net2 Ba ECH EtherNet IP Weigh Bar is a registered trademark of Av
7. 105 0 Deadload 105 0 Use this item to set the point at which under range lower dashes or over range upper dashes are displayed You can choose between 105 of capacity or 9 divisions over capacity This completes the Scale section of the configuration E1070 e tools Software User s Manual Application Icon E ES h Applications General Weighing tab Accumulator tab Click the Application icon on the Menu Bar and the following window ap pears Configuration Applications These tabs give you access to each application which you can enable If enabled some applications may have more settings Each are discussed below General weighing is the first tab that appears since it is the default applica tion on the E1070 It is enabled automatically since it is the default applica tion Choose Print Format s Type in the print formats 0 10 that you want printed when the PRINT button is pressed during normal operation Multiple print formats must be typed in ascending order For example Enter 0123410 and print formats 0 1 2 3 4 and 10 are sent out the serial port Click on the Accumulator Tab Enable this application by clicking on the Enable button Configuration Applications Choose Print Format s Type in the print formats 0 10 that you want printed when the PRINT button is pressed during normal operation Multiple print formats must be typed in ascending order F
8. 4 and 10 are sent out the serial port Click the Serial icon on the Menu Bar and the following window appears Configuration Serial Pott Pat 2 Baud Rate 9600 Data Bits e Parity Mone T Handshake Mone S Mode Folling Character Enquire Joos 05 zENQ Print Formats Enquire n Use Leading Zero s Enquire Motion In this window you set up the serial communication parameters for Port 1 and Port 2 Choose the port and then select values for each item from its drop down list Baud Rate Choose from 300 to 115200 Data Bits Choose from 7 or 8 Parity Choose from None Odd or Even Handshake Choose from None RTS CTS or Xon Xoff Mode Depending on the mode you pick a secondary choice may appear All are explained below Broadcast Enquire RD4100 RD Mode 1 RD Mode 2 Causes a Print Format box and Rate box to appear Choose Broadcast to cause the configured print format s to be sent out the serial port continuously at the rate chosen when there is no motion on the scale Causes a Print Format box and Polling Character box to appear Choose the polling character which when received by the indica tor will cause the print format s to be sent through the serial port The polling character can be any ASCII code from 0 to 255 hex 00 to FF Choose from the Scale Manufacturer s Association list of commands and responses in Appendix 1 of this manual Like Broadcast except
9. E1070 Avery Weigh Tronix etools a Printer Lem Net Manage Fieldbus 1 TENE Fieldbus Type Fieldbus 1 None disabled lt fieldbus Lem Fieldbus 2 Net Manage Fieldbus 1 NUM CAPS SCRL 3 1 2004 1 27 PM You can choose from Fieldbus 1 or Fieldbus 2 With either of these you can configure the networks shown in the illustration below Settings Map Data SMTP Fieldbus Type Mone disabled x Device Met Frotibus Control Met Ethernet IT Client Ethernet Modbus CF Ethernet 3 F1 Remote O Pick the network from the drop down list and the appropriate boxes will appear and or appropriate tab s will activate Follow the steps in the next pages to configure each network E1070 e tools Software User s Manual 33 l o gt Click on DeviceNet in the drop down list to configure a DeviceNet network DeviceNet DeviceNet The window looks like this Net Manage Fieldbus 1 Settings Map Data SMTP Fieldbus Type D Device Met fieldbus Valid nodes for DeviceNet are Indicator Device Met 0 to 63 Node Baud Rate jo 125k DeviceNet Select Indicator node Key in the node for the indicator Acceptable values are 0 to 63 See note at If an address greater than 63 is left used the indicator will set the node to 63 after the download Select Baud Rate Select a baud rate for network communications Available choices are 125K
10. configure a EtherNet 1 IT network The window looks like this Net Manage Fieldbus 1 Settings Map Data SMTP Fieldbus Type Ethernet IT fieldbus Indicator Ethernet IP Address Host IP p jd e e b FEEF SMTP P DHCP Enable o No o Wo Gateway Pp s Socket Mode Subnet p Wo s 9 Port 0 Select Indicator IP Address Key in the IP address for the indicator If you enable DHCP Dynamic Host Configuration Protocol the IP address for the indicator is not required Select Ethernet Addresses Key in the IP address for the host IP SMTP Gateway Subnet and key in the port number that the indicator and the remote host will be connected on Set Socket Mode SMA the SMA protocol over the Ethernet connection This is the exact same protocol used on the serial ports See the Service Serial section of the E1070 Service Manual for details Polled If Polled is chosen you will be prompted to select a polling charac ter Choices from 0 to 255 When the polling character is received on the Ethernet connection the indicator will act as if the PRINT key has been pressed all of the formats to print will be sent out of the configured port If you want the print format s to be sent back on the Ethernet connection the print formats must be configured for tcpip1 net1 or tcpip2 net2 Click the SMTP tab and the following is displayed Net Manage Fieldbus 1 Uzer N arme me
11. in the indicator with your new ones You can save the con figuration file for use on multiple indicators or as a backup for your system You can also upload the configuration of an indicator into the program and modify it Below is a small list of the items you can enable and configure with this software e Capacity e Networks e Division size e Applications e Zero and Motion parameters e Inputs e Units of measure e Outputs e Serial communication e Print formats Starting e tools After installation covered in the Getting Started manual click on START gt PROGRAMS gt Avery Weigh Tronix gt etools The program will start and you will see the following window e tools Index Avery Weigh Tronix m Model E 1070 Index Choose your indicator model from this drop down box Choose E1070 for this manual then click on Run E1070 e tools Software User s Manual 5 If you click on the Avery Weigh Tronix logo the AWT web site will open The following window is displayed t e tools untitled3 E1070 DIE File View Tools Help Diels UU SjalNa naaa E1070 Avery Weigh Tronix TE UU etools oum Firmware Download EC C EE Se T el a Site Selector Command Bar Firmware Download Application rT Browse Tool Bar Bootloader CAProgram FilesyAvery Weigh Tronix e tools Bootloaders C Program Files M e n u B a r Configuration Window Status Bar
12. it will send information even when the scale is in motion If you pick format 0 a default G XXXXXX Ib format will be sent Select this to send G XXXXXX Ib at the rate you pick in the Rate box Select this to send the same as RD Mode 1 annunciators E1070 e tools Software User s Manual 2f Analog Output Icon requires indicator option e Analog Out 28 RD Mode 3 Select this to send the same as RD Mode 1 will accept the keys presses from the remote TARE SELECT ZERO PRINT UNITS RD Mode 4 Select this to send the same as RD Mode 2 accepts the keys presses from the remote TARE SELECT ZERO PRINT UNITS RS 485 When you choose this a Muli drop Address box appears The address can be any ASCII code from 0 to 255 hex 00 to FF 485 HD When you choose this a Muli drop Address box appears The address can be any ASCII code from 0 to 255 hex 00 to FF There is alSo two checkboxes Use Leading Zeros Leading zeros fill in any open spaces before a weight value in a printout Enquire Motion If checked the scale will respond to an enquire code only when there is no motion on the scale Click the Analog Output icon on the Menu Bar If you enable analog output the following window appears Configuration Analog Out Analog Output Basis Weight for Analog Output Gross Weight Minimum M asinum jo 5000 Output Adjustment Offset Set the Basis Choose what the output will be
13. number of custom units If your new custom unit is Custom Units smaller than one CAL UNIT then you divide one cal unit by the number of custom units it takes to make up a single CAL UNIT Multipliers are limited to a total of seven digits by the display Example 1 16 ounces 1 pound Do the math one cal unit number of custom units the multiplier 1 16 0 0625 So with pounds selected as our CAL UNIT we would key in 0 0625 for the multiplier Example 2 1000 Grams 1 KG Do the math one cal unit number of custom units the multiplier 1 1000 0 001 So with KG selected as our CAL UNIT we would key in 0 001 for the multiplier Enable the units of measure you want available when you click on the indicator s UNITS key The shaded unit under Units Enabled is a result of the selection in Calibration Units lf Custom is checked under Units Enabled the dialog box changes to this Configuration Scale Calibration Zero Motion Tare E Mail System Filter Ranges Capacity Weight Calibration Units 5000 Ib 5000 Ib ib Division Decimal Position Weight Source 1 i wong Analog Units Enabled Custom Units Iv b Name none M kg Conversion Factor M iLustomi 1 00000 Type a name for the custom unit of measure Type in a conversion factor based on the primary or calibration unit of measure See the large note in the left column of this page E1070 e to
14. power to the indicator by pressing the power key 2 Select the Firmware tab in E tools then choose Download The follow ing is displayed Caution Be sure to turn off any screensavers before download ing new firmware or enable the Prevent screensaver while downloading firmware option in the TOOLS OPTIONS dialog box Firmae Download NUM cas sow BE 1 50PM 3 Use the Browse button to select the desired version of firmware to download into the indicator 4 Use the browser window to find and select the appropriate firmware for download then click the Download button Download 5 Caution The user will be warned to check all connections The indica tor uses flash memory any interruption in power or communications may damage the flash memory 44 E1070 e tools Software User s Manual A Firmware download to the indicator may take several minutes ANY INTERRUPTION OF THE SERIAL COMMUNICATION PROCESS COULD RESULT IN THE NEED TO RETURN THE UNIT TO THE FACTORY TO BE RESET Before proceeding we recommend that you check the serial cable and disable all screensavers and automatic power savers hibernation Features Check OF bo proceed with the download or Cancel to abort 6 Click Cancel to abort firmware download or select OK to download firmware 7 After selecting OK press the power button on the indicator until the file size is displayed 8 While downloading firmware a progress bar ap
15. printed when the PRINT button is pressed during normal operation Multiple print formats must be typed in ascending order For example Enter 0123410 and print formats 0 1 2 3 4 and 10 are sent out the serial port Remote Display tab Click the Remote Display tab and if you enable it you will see the following choice Configuration Applications p Gaia SCS gt Choose Print Format s This section for future use E1070 e tools Software User s Manual 25 26 Choose Remote Display Mode Mode 1 The indicator acting as the remote display will show the Gross or Net annunciator and the characters displayed on the master indicator Mode 2 The remote display will show the Gross or Net annunciator the characters and all annunciators displayed on the master indica tor Mode 3 The remote display will show the Gross or Net annunciator the characters displayed on the master indicator and allows zeroing of the scale from the remote Mode 4 The remote display will show the Gross or Net annunciator the characters and annunciators displayed on the master indicator and allows full function of all the keys on the remote Choose a Port Choose which port 1 or 2 serial information is coming into This concludes the Application Icon section E1070 e tools Software User s Manual Serial Icon You must type in the print format numbers in ascending order For example Enter 0123410 and print formats 0 1 2 8
16. view Tools Help plela LL Site NA Model E1070 Avery Weigh Tronix etools Calibration Zero Motion Tare E Mail System Filter Ranges Capacity Weight Calibration Units sooo Ib 5000 lb Ib Applications Division Decimal Position Weight Source S SN 1 none Analog Serial e Units Enabled Iv us M kg T Custom Net Manage Firmware Configuration Scale NUM ceps sce 843 200 2 00PM It is in these dialog boxes that you choose all the configuration parameters for your indicator and scale setup When all your parameters are set you connect your PC serial port to the serial port of the indicator and click the download down arrow button on the button bar The file is sent to the indicator and all the new parameters take effect When you key in values the software validates the entry so that you cannot enter an incorrect value For example if a percentage rate say 0 100 is required and you key in 123 then the value will be highlighted and you will not be able to tab to the next input box until the value is corrected This will also occur if you enter an invalid character such as 12w instead of 123 You can either edit and correct the value or while the entire value is high lighted you can press the DELETE key and start over If the entry box is completely clear and you tab to another box the default v
17. 39 Ea eA GE 40 SZT N Le 1 SOPVEL E 41 SANO Te F UO oe E E aus Uo scuSMm iude 42 Downloading acc WT 42 Uploading E TEE 43 Downloading Glo T T OTT 44 Appendix A Print Format CormlimaridS esse esse av ee eee ee 46 Appendix B Mainboard Network LED Diagnostics 48 Appendix C Network TOK E 49 E1070 e tools Software User s Manual 3 Minimum system requirements To install this software you need a computer with the following minimum specifications PC with Microsoft Windows ME 2000 XP e Pentium Ill processor 700 MHz e 128 MB RAM e 20 MB of hard drive space e CD ROM drive e RS 232 communication port or USB to serial converter 4 E1070 e tools Software User s Manual Introduction Welcome to the Avery Weigh Tronix e tools software manual This software makes configuration of the Evolution series of indicators a quick PC based operation This document is meant to help you understand what this software is capable of and how to use it effectively with your model E1070 indicator The Evolution series of indicators are configurable through the front panel and a menu structure built into the indicator s software The e tools program makes this front panel configuration unnecessary Easy on screen check boxes drop down lists and data entry boxes make configuration quick When done you download the file you create to the indicator via RS 232 serial cable The new program overwrites the configu ration settings
18. Avery Weigh Tronix pU OIOHaMEENENENNENNNEEEABBSBBS NM E1070 e tools Software TM Wi EA dB A The Power of Intelligence E1070 e tools User Instructions ENGLISH 43127 0016A e1 May 22 2006 TAE EHI OI NOIA UINN I ITE E RT IA AA T E1070ETOOLS REV2006 U P65 Table of Contents Table of Contents ee ee een ee een teen eens 3 Minimum system Re UE Men E 4 Ierger al tele MN um 9 Star hid Eae coetus E reste nousce Seance sod eeyUng E E A O E codes d S CdeUb sU LUE LUE 5 Command BO eects TE e RCM USDU HU ETUR SEI AU RM RNC tup POP TUNE ADMIRER ATEM ME T lei d EN 8 Configuration VWINdOW EE 9 S ll te E E E E A E EA E E EE A T AEE 9 Creating and Downloading a Configuration Ee 10 lese SANS TM T 10 ve tige ONS MR 10 CONFIGURING Configuration Button 11 AVS 1 11 AR elel iila qM eo MERERI RR TT 19 Seal COIN EN 2f Analog Output Icon requires indicator option 28 Pulse Counter Icon requires indicator option 29 THUS VC OD CRT HE 29 CONFIGURING Printer BUOM coria eir hers Fat us Fu R a x via Pen ba tid ie 30 Creating a Pon en oo seene c tessa source seesantessecusea E EE dus ee PU PRUNUS Dos 31 CONFIGURING Net Mange Button 33 Bran 0 34 PROFIBUS geed Ee 35 ControlNet requires indicator option se eee eee 36 iura cc T once 37 EtherNet 2 ModDuUS TOP EE 38 SZT Ve Leite el gm
19. Below is a sample of all inputs enabled and an action assigned to each input See list of choices in left margin Configuration Trips Input Output Enable Actian v Input 1 zero v Input 2 Tare When you click the Outputs tab you are shown three checkboxes for the three outputs See example below Click on the checkbox for the output you want to enable Click again to disable an output Input Output Enable T Output 1 T Output 2 Output 3 E1070 e tools Software User s Manual 29 When you click the Printer button in the Menu Bar and then click the Print CONFIGURING Format icon you will see the screen shown below Use this window to create Printer Button and save custom print formats t e tools untitled1 E1070 x File View Tools Help Avery Weigh Tronix etools LL Printer Print Format Print Terms x Format Edit View Print Format go ja AE IN Si mim Date Format Name Weight B 1 Checkweight Trips Print Format 0 is the default print format reserved for each application mode Recipe Ingre PLU Strings Miscellaneou Control Code Hex Codes E EB BERE REESE Formats 1 9 are available for any application mode Print Strings Enter lt CR gt Format 10 Format 0 for the General Weighing mode Format 11 Format 0 for the ACC mode Format 12 Format 0 for the Batch mode Format 13 Format 0 for t
20. Click on Edit gt Enter Key and select what pressing the ENTER key on the keyboard will insert See illustration below Edit View Cut Copy Paste io Insert Term Delete Term Enter Kev Insert Nothing Go to End wv Insert Ch Insert CR gt ZLE gt E1070 e tools Software User s Manual 31 Print Format 0 is the default print format reserved for each application mode Formats 1 9 are available for any application mode Format 10 Format 0 for the General Weighing mode Format 11 lt Format 0 for the ACC mode Format 12 Format 0 for the Batch mode Format 13 Format 0 for the Target mode Format 14 Format 0 for the Count mode Format 15 Format 0 for the Top mode 32 5 Insert the text cursor in the editing window by clicking anywhere in the window 6 Expand the terms list by clicking on the plus symbol Printer Print Format Time Print Terms Terme cM TIM Tine as configured El Date DAT Date ias configured DER 4 Digit Year Weight GWT Gross NUT Net SAT Semi uto Tare UN Units PCE piece Weicght CHT Count GTO Gross Total STO Net Total WST Weight Steady PUT Desk Hold DSP Print Displayed We ACT Print Active Wr bbrev C T Checkweight CLA Low Accept CHA High Accept El Trips TTY Target El PLU PLU Number DES Description FUF Tare PUT Transaction Count Total PCT Count Total LST Net Total L
21. GT Gross Total Strings BLM iscellaneonus zd 4 k 7 Double click a term to insert it at the cursor position or click on a term and click the Insert Term button B Press the ENTER key when necessary to enter the carriage returns and or line feeds you picked in step 4 See sample below Format Edit view D lele amp e la Format Mame Port h Hh fi TE TIM L lt CR gt DAT L lt CR gt GWT L CRS Print Strings S Z EE Enter CDs 9 When you are finished laying out the look of the format you can go to the next format you want to create or continue with creating your con figuration file E1070 e tools Software User s Manual CONFIGURING Net Mange Button Configuration Printer Net Manage Fieldbus 1 Fieldbus z These files are needed to config ure the PLC so it will communi cate to the E1070 indicator PROFIBUS AWTX0913 GSD DeviceNet E1070 Dnet EnetlP EDS ControlNet ABS CNT V 1 5 EDS EtherNet 3 EtherNet P E1070 Dnet EnetlP EDS These files can be found in the etools folder on your hard drive Typically this is C program files avery weigh tronix e tools networks When you click the Net Manage button and the Fieldbus 1 icon in the Menu Bar you will see the screen shown below Use this window to configure your network connections if any t e tools untitled1 E1070 i EM File View Tools Help ee Diam U Site NA gt Model
22. al This shows the total number of bytes used by the indicator This information is required by the PLC programmer and is automatically calculated 39 Remote UO Click on Remote lO in the drop down list to configure a remote I O network The window looks like this Net Manage Fieldbus 1 Settings Map Data SMTP D fieldbus Valid addresses for Remote I O Hack Settings are 0 to 59 Address Size Baud Rate RIO Mode a D Full D BZ E D Cyelic Start Quarter Last First T uo Select Rack information Address acceptable values are 0 to 59 See note at left If an address greater than 59 is Size can be 1 4 1 2 3 4 or Full used the indicator will set the address to 59 after the down load Last can be NO or YES Start Quarter can be First Second Third or Fourth Select Remote I O settings Baud Rate can be 57 6K 115 2K or 230 4K Remote I O mode is Block or Cyclic Click the Map Data tab and the following is displayed This shows the spacing of each Net Manage Fieldbus 1 piece of data as it Settings Map Data SMTP Choose to create the will show up on Scale Inbound Data Map D Inbound Data Map or Midi mag Outbound Data Map Lol EE by selecting your NEP a IU i choice here MR e L 7 2 S EP xp bia id i A ee Choose Endian Format rop down list o o3 H Big or Little here network tokens INC HEP E Pg L 1 See Ap
23. alue for that item will automatically be inserted in the box E1070 e tools Software User s Manual 9 Creating and Downloading a Configuration File You can edit an existing file by opening the file making the desired changes and saving the file Setting the Defaults Setting Options General tab 10 The steps you take to create a new configuration file are e set the defaults e configure all scale indicator parameters e save the file e download the file to the indicator Use this item in the upper right corner of the program window to choose your instrument location NA North America EU Europe Choosing the correct one will s t defaults to your location s requirements Mad E1070 Choose the location where the indicator will be used Choosing the correct one will set defaults to your location s requirements Click on Tools Options to see the General tab shown below anz xi General R5 232 COM Miscellaneous Beeper Sound Effects Load last used configuration file at startup Firmware Downloading IZ Allow selection of firmware bootloader Prevent screensaver while downloading firmare E Cancel In the this window you can enable or disable the following options Beeper This is a PC warning beep when an error is detected Sound Effects These are the sounds made as you navigate the e tools program Load last If enabled the last saved file will ope
24. anual 15 System tab The following is displayed when you click on the System tab Configuration Scale Auto Print Enable Error Indicator Off Iv DeadloadEnable Display 10 Update Rate Time Warning ho gems HE Separator Date Error Decimal MMDDYY 7 50 Time Date Format Deadload Auto Print Enable Error Indicator Deadload Enable Display Time Date Format Use this item to set a minimum weight under which the indicator will send out the configured print format This is a percentage of scale capacity Choose the function that is associated with the bottom LED error indicator on the display Choices are Off SensorComm Network 1 or Network 2 If you enable this the Deadload choices appear in the bottom right of the window Use these items to choose a percentage of scale capacity at which the scale gives a warning or causes an error This is used if Sensor Comm is enabled Update Rate Set the display update rate Choices are 1 2 5 10 Hz Separators Pick a decimal point or a comma for the fraction delimiter for the display For example if you pick Decimal the display will show 10 5 If you pick Comma the display will show 10 5 Time Choices are 12 hour AM PM or 24 hour format Date Selectthe style of date display Choices are shown below Time D ate Format Time 24 hour Date MMDDYY 16 E1070 e tools Softwa
25. ap Data SMTP Fieldbus Type D Contro Mat fieldbus Indicator Made p Select Indicator node Key in the node for the indicator Acceptable values are 0 to 63 See note at left Click the Map Data tab and the following is displayed Net Manage Fieldbus 1 Choose to create the D Inbound Data Map or the PLC dae 7 Outbound Data Map by selecting your c MS choice here E Outbound Click here for a Choose Endian Format drop down list of p Big or Little here network tokens G See Appendix C zh for full list UL 3 Buda fang ee EE RR GEN drop down list of Petras word arde trade swap the Data Types word order Delete Variable Total Bytes 0 Data Type Type Data otBytes Range of Valus s o L lee FLOAT 6 Float 4 A410E to10E 36 E1070 e tools Software User s Manual This shows the total number of bytes used by the indicator This information is required by the PLC programmer and is automatically calculated EtherNet 1 IT DHCP Dynamic Host Configu ration Protocol is a protocol for assigning dynamic IP ad dresses to devices on a network Key in the User Name for the indicator Key in the Domain Name for the indicator Key in the email address for the indicator Key in the email recipient s address Key in the subject of the email Click on EtherNet 1 IT in the drop down list to
26. based one Gross Weight or Net Weight Set the Weight for Analog Output For Example The minimum weight is 0 pounds and the maximum weight is 5000 Ibs This represents the minimum 4mA output at O pounds and the maximum 20mA output at 5000 Ibs Set the Output Adjustment For Example Increasing the offset amount above 0 will increase the 0 weight value Increasing the span percentage will increase the maximum weight value Both of these adjustments increase the voltage from the physical card E1070 e tools Software User s Manual Pulse Counter Icon requires indicator option Pulee Counter Trips Icon Choice None F1 Key Tare Units Print Tare Can Start Stop Input Action No action Remote F1 Remote TARE key Remote UNITS key Remote UNITS key Clear active tare Starts batch in batch mode Stops batch in batch mode Click the Pulse Counter icon If you enable the pulse counter you will see the window shown below Configuration Pulse Counter Fulse Counter 1 Pulses u a m Y ou need to set the ratio Set the ratio Enter the ratio of pulses calibration unit of measure For example You have a device which pulses 3 000 times gallon of water Water weighs approxi mately 8 lbs gallon Your equation would be 3000 8 375 This is the value to enter in the Ratio box Click the Trips icon Use this to enable and assign key functions to specific inputs and to enable or disable outputs
27. e to save it to the folder of your choice The file name does not need to include a file type E tools will automatically save your configuration file as specified by the indicator choice shown in Save as type drop down box The next step in the process is downloading the finished file to your indica tor 1 Connect the PC to the indicator which requires the configuration via the chosen serial communications port on the computer 2 Click the Download Configuration icon 3 The following message will be displayed Download E J Ready to download the untitled1 E1070 configuration data File to the indicator 4 Verify that the indicator is turned on and in weigh mode o Click Yes to download the indicator configuration The following screen will appear and the indicator will display the word bUSy oS Downloading configuration data OVERVIEW E1070 Close after successful data transfer EI E1070 e tools Software User s Manual 6 Once the download is complete the window will change to show a Pass or Fail condition Progress Progress Configuration download COMPLETED o Conliguralion download FAILED Emor 4U DVERVIEw E 1070 OVERVIEW E1070 Close after successful data transfer M Close alter successful data transfer 7 Once configuration download is complete the indicator is ready to be calibrated 1 To upload an indicator configuration from the indicator to E tools connect the ind
28. ery Weigh Tronix and may be registered in certain jurisdictions ODVA Ethernet IP and DeviceNet are trademarks of ODVA PROFIBUS is a registered trademark of PROFIBUS International Standard Scale amp Supply Company 25421 Glendale Avenue Redford MI 48239 313 255 6700 www standardscale com Avery Weigh Tronix
29. f recent files Exil close the program If you click View the following drop down menu appears VIEW w Status Bar Click Toolbar to toggle the toolbar on and off Click Status Bar to toggle the status bar on and off If you click Tools the following drop down menu appears Tools Options Click here to open the Options dialog box Reports Click here to print a configuration report Clear Recent Files Click here to clear recent files If you click Help the following drop down menu appears Help Users Manual About Click here to open the user s manual PDF Click here to see software information E1070 e tools Software User s Manual T Menu Bar As you click on each menu bar item the related icons appear All four menu EE items are shown below Each icon will be covered in the Configuration section of this manual Configuration Configuration Configuration Configuration Printer Printer Printer Net Manage Net Manage Firmware Frint Format Applications Er E Fieldbus 2 Serial Analog Out EE Pulse Counter Trips Printer Net Manage Net Manage Firmware Firmware Firmware 8 E1070 e tools Software User s Manual Configuration Window Entering Values When you click on a menu bar icon the related configuration dialog box appears in the configuration window Below is an example t e tools untitled3 1070 File
30. ge 31 38 Editor Default 1 146 92 RPV n Active Recipe Recipe NL For preact values in recipe 147 93 RIU n Active Recipe Recipe Ingredient x units MANDATORY HEX fis Range 31 38 Editor Default 1 For target weights in recipe MANDATORY HEX fis Range 31 38 Editor Default 1 For ingredient units Ib or kg for weight based ingredients sec for time based ingredients cnts or gallons for pulse counter based ingredients To be printed after the target or actual ingredi ent value Count Count Weight J Z0 O 153 99 STO PNetAccumuaeton Weight 155 9B PLU PLUNumberData PLU LLL 46 E1070 e tools Software User s Manual Dec HEX Token Application Group parameter 16 9c ps PUD 23Q d PU 0 162 A2 DIS Remote Display Status Miscelaneos lt lt lt 170 AA VER Software Version Number_ Miscellaneous lt lt 173 AD WST WeightSteady Wein 55 170 B2 PUP Tare associated with the PLU PLU lt lt 184 B8 PUT PLUTotals Information PU 5 188 BC PCT PLUCountTotal e 189 BD LST NetAccumulator PU 5 OYO 190 BE LGT Gross Accumulator PLU 55 5 200 C8 DSPt n Print the displayed weight Weight OPTIONAL ASCII Range 2 9 Indicator Default 6 NULL Null Token Sting
31. guration Applications Accumulator Batching Checkweigher Counting Peak Hold Remote Display General weighing Print Farmat z S epulo o CG Bulk t Dribble Sample Min Weight Choose Print Format s Type in the print formats 0 10 that are to be printed when the PRINT button is pressed during normal operation Multiple print formats must be typed in ascending order For example Enter 0123410 and print formats O 1 2 3 4 and 10 are sent out the serial port Choose a Sample Mode Bulk sampling In this sampling method you place the specified sample number of items on the scale all at once in bulk and after motion stops the scale automatically starts to calculate piece weight and then shows the count Dribble sampling n this sampling method you can count out the specified sample number of items onto the scale and when you are ready press the F1 key and after motion stops the scale starts to calculate piece weight and then shows the count Choose the Sample Minimum Weight and the Sample Size Set the minimum sample weight as a percent of capacity that the sample must weigh Set the default sample size to prompt the operator to place on the scale E1070 e tools Software User s Manual Peak Hold tab Click the Peak Hold tab and select Enable Peak Hold Application The following choices will appear Configuration Applications Choose Print Format s Type in the print formats 0 10 that are to be
32. he Target mode Format 14 Format 0 for the Click on the new file icon to start a new print format Count mode Format 15 Format 0 for the Top mode Printer Print Format NUM CAPS SCRL 7 21 2004 1 58 PM Printer Print Format Print Terms Format Edit view Terms Ez Cu ems O sete mU 88 Date Format Hame Weight Checkweight The screen should look similar to this Printer Print Format Print Terms X Format Edit view E Terms ET zum nj jag Alan Date Format M ame Port Y Weight fi Print Format 1 fi Checkweight aa Trips z Recipe Ingre PLU Strings Miscellaneou Control Code Hex Codes Print Strings Editing Window 30 E1070 e tools Software User s Manual Creating a Print Format The print format command bar is illustrated below with explanations for the functions of each Duplicates what these six keys ER Ca do plus assigns default insert SE CS E A when ENTER key is pressed on your keyboard Duplicates what Opens a new these two keys do format Format Edit view Cut Copy Paste Inserts Deletes Move Show Show selected selected insert strings tokens term term pointer to end To create a print format follow these steps 1 Choose a format from the drop down list above the editing window 2 Type a print format name in the Name window 3 Pick a port to use when printing the format 4
33. icator to the PC Uploading a File Indicator must be unsealed for 2 Open the E tools program and click the Upload Configuration button on a file to be uploaded from it the Tool Bar See the Service Manual for details 3 The following message will be displayed 1 J Ready to upload the Overview E1070 configuration data File From the indicator 4 To upload an indicator configuration from the indicator to E tools connect the indicator to the PC 5 Open the E tools program and click the Upload Configuration button on the Tool Bar insert upload icon here gt 6 The following message will be displayed Progress o Uploading configuration data OVERVIEW E1070 Close after successful data transfer E1070 e tools Software User s Manual 43 7 Once the upload is complete the window will change to show a Pass or Fail condition Progress Progress Conta airn upload COMPLETED Configuration upload FAILED OVERVIE E1070 OVERVIEW E1070 Close after succerstul dala transfer Close alter successtul dala transter 8 After uploading the indicator configuration it is recommended to save the file Refer to section Saving a File for detailed instructions The indicator configuration can now be viewed and edited as needs demand OMM This item allows you to download new firmware to the indicator s micropro Downloading Firmware cessor when needed for proper servicing 1 Turn off
34. mple Mode If you pick Sample Mode the Target Window box shown below appears in the dialog box Display Graduation 1 Divisions Target Window L Divisions E1070 e tools Software User s Manual User places a correct weight product on the scale and presses the F1 key The indicator will use this weight to run the display Upper and lower limits will automatically be one division above and below the target weight respectively by default This default vaule can be changed using the Target Window Type in a target division size other than the default 1 Each fan graph segment is equal to 1 scale division but this can be changed in the Display Graduation box The TARGET light stays lit if weight is within the upper and lower limits TARGET lin ill dU AU Each graduation 1 division default Configure Outputs Choose between Standard and Target Standard Configure the outputs using the F1 key and keying in the OP1 OP2 and OP3 values Target Outputs are set according to the selected target weights Output 1 activates when the Under condition is met Output 2 activates when the Accept condition is met and Output 3 activates when the Over condition is met Display Graduations Chose how many divisions each fan graph segment is equal to E1070 e tools Software User s Manual 23 Counting tab Click the Counting tab and select Enable Counting Application The following choices will appear Confi
35. n terms of divisions for a period of time in seconds If a weight changes less than this number of divisions in the time period you select the motion light turns off and the weight is considered stable See note at left 14 E1070 e tools Software User s Manual Tare E Mail tab The following is displayed when you click on the Tare E Mail tab Configuration Scale Calibration Zero Motion Tare E Mail System Filter Ranges Tare v Pushbutton Tare v Keyboard Tare Auto Tare Clear Preset Tare Send E Mail When amp SensorComm error occurs A cell is ghosted in SensorComm box An overload or underload occurs Here you can set the following Pushbutton Tare Auto Tare Clear Keyboard Tare Preset Tare Send Email When If you enable this item you can use the TARE key to tare a weight from the scale If you disable this item you cannot tare using the TARE key If you enable this item the tare will be automatically cleared when the weight falls below the value set under Gross Zero Band discussed on the previous page If you enable this item you can key in a tare weight and press the TARE key to activate the tare value If you enable this item you can use a tare that is held in the PLU memory channels Select any or all instances when an email notice is sent by the indicator Email is setup in the Networks window E1070 e tools Software User s M
36. n when the e tools program is started Allow selection lf enabled you can select a firmware bootloader under the Firmware menu bar item Prevent Screen This will disable the screensaver to stop it from inter rupting the download process E1070 e tools Software User s Manual CONFIGURING Configuration Button Scale Icon RS 232 COM tab Click the RS 232 COM tab w Options Choose the serial port through which your computer will download the files Set a timeout for how long the system will try to download before the attempt is aborted Under the Configuration button on the menu bar there are six icons Scale Applications e Serial e Analog out Pulse Counter Trips Each is explained in detail below Click on the Scale icon and the following dialog box appears Configuration Scale so e o eo eo NN The dialog box has several tabs Each tab is explained below E1070 e tools Software User s Manual 11 Calibration tab Under the Calibration tab type in select or enable the following items Capacity Weight Calibration Units Division Decimal Pos Weight Source When using a scale with SensorComm always start with B1 and continue consecu tively i e B2 B3 etc Type in the scale capacity Type in the calibration test weight size Choose Ib or kg as the calibration unit of measure Type in the division size of your displayed weight Choices are 1 2 5 10 20 50
37. nd each ingredi ent is determined by the percentage set in the recipe Gross You set the gross weight at which each ingredient will stop The ingredient is complete when the gross weight on the scale reads the value that was set regardless of the weight on the scale when the batch was started Enable or disable the Preact A preact is the time it takes an ingredient which is falling from an auger or other feeder to reach the scale after the auger or feeder is shut off There will always be material in free fall after an ingredient is shut off and the indicator will automatically calculate this and update this value The first time a batch is run overage for any ingredient weight is calculated and the next time the ingredient is being weighed the output will be shut down so approximately 70 of the overage is reduced This occurs each time a batch is run so that the system quickly learns and produces accurate batches Define the ingredients To define an ingredient you Choose an ingredient Choose the basis for the ingredient The Basis of each ingredient can be weight time or pulse counts Scale If an ingredient basis is scale weight the output acti vates at the appropriate time and deactivates when the weight set in the recipe is reached Time If an ingredient basis is time the output activates for the time set in the recipe and then deactivates Counts Ifan ingredient basis is counts from a pulse counter the o
38. oftware User s Manual EtherNet 3 Modbus IP Click on EtherNet 3 Modbus IP in the drop down list to configure a EtherNet 3 Modbus IP network The window looks like this Net Manage Fieldbus 1 Settings Map Data SMTP Fieldbus Type Ethernet 3 IP Indicator IP Address ff fp Select Indicator IP Address Key in the IP address for the indicator Gateway Key in the Gateway Subnet Key in the Subnet D fieldbus o o fo uo Click the Map Data tab and the following is displayed This shows the spacing of each Net Manage Fieldbus 1 piece of data as it Settings Map Data SMTP Choose to create the will show up on Seale inbound Gata Map D Inbound Data Map or the PLC wem Offset Variable Gate Tue wr U Outbound Data Map OY 5 5 EE by selecting your LE Qu Outbound Click here for a L9 2 drop down list of EE 3E coe O 7j Choose Endian Format See Appendix C LT Eni Ferm Click here for a eee Big Endian Click here to drop down list of Ste EE trade swap the Data Types Delete Variable Total Butes L Gl word order Data Type Type Data WofBytes Range of Valus ss o SignedChar 1 t1 se 2 Signedinieger 2 azero Unsigned integer 2 0 10 65535 Signed Long A 2 147 483 647 to 2 147 483 647 Unsigned Long 4 0 to 4 294 967 295 Fla J 4 1 0E to 1 0E E1070 e tools Software User s Manu
39. ols Software User s Manual 13 Zero Motion tab The following is displayed when you click on the Zero Motion tab Configuration Scale Calibration Zero Motion Tare E Mail System Filter Ranges Zero Range Center Zero Range Gross Zero Band 100 da oz Jon p piv Auto Zero Tracking Motion Divisions Divisions 3 00 3 00 Time Delay Time Delay 1 00 PES 1 00 Eae Under the Zero Motion tab set the following Zero Range Type in a percentage of capacity within which the ZERO key will zero the scale Center Zero Range Select a window size for the center of zero annuncia tor You can choose between x74 and 7 division of zero weight When the weight falls within the window size the center of zero annunciator lights Gross Zero Band This is a parameter used to trigger the tare clear function covered under the Tare tab You can select values between 0 and 100 divisions Auto Zero Tracking Type in a division size and time delay in seconds The AZT and Motion division size you pick defines a range above and Common Division selections below zero When scale weight is inside this range for 0 25 the number of seconds you picked 75 of the weight 0 5 will be zeroed The indicator will repeat removing 72 1 0 the weight every X seconds X being the number of 20 seconds you have picked See note at left 3 0 Motion Type in a division size and time delay in seconds This defines the stability window i
40. omatically by the indicator Filling In Fill mode any recipe that has been setup is ignored The filling process is run based on the values set for the outputs In order to complete the filling process at least one output must be enabled Continuous Continuous batching mode This mode is very close to the Auto mode In continuous mode another batch is started immediately after the previous batch has fin ished In Auto mode the user must press the F1 key to start each batch Press the F1 key to start the filling process 1 a If output 1 is enabled and the net weight on the scale is below the value of the output output 1 will come on b If output 2 is enabled and the net weight on the scale is below the value of the output output 2 will come on c If output 3 is enabled and the net weight on the scale is below the value of the output output 3 will come on 2 Each output will remain on until its output value is met 3 The filling process can be restarted by pressing the F1 key E1070 e tools Software User s Manual Select Hecipe Number When you pick a recipe number the following appears in the window Recipe Ingredient U S m o Humber Type H Constent You can now create a recipe using this Recipe area of the screen Choose Type of Recipe Constant Batches are all the same size and the weight of each ingredient is predetermined by the recipe Percentage Batch size is chosen by the operator a
41. or example Enter 0123410 and print formats 0 1 2 3 4 and 10 are sent out the serial port E1070 e tools Software User s Manual 19 Batching tab To terminate the filling process press the F1 key All outputs will turn off and the process will start over when the F1 key is pressed again 20 Click the Batching tab and select Enable Batching Applications The follow ing choices will appear Configuration Applications Accumulator Batching Checkweigher Counting Peak Hold Remote Display General Weighing Enable Batching Application Mode Automatic Automatic Print Format s 0 Manual Filling Continuous Recipe Number a Preact Type Constant Total EEN Choose Print Format s Type in the print formats 0 10 that are to be printed when the PRINT button is pressed during normal operation Multiple print formats must be typed in ascending order For example Enter 0123410 and print formats O 1 2 3 4 and 10 are sent out the serial port Select Automatic Manual Filling or Continuous Mode Manual If the recipe is set up for Manual mode you press the F1 key to start the batch and you need to press the F1 key each time a output is reached to activate the next ingredient output Automatic If the recipe is set up for Automatic mode you press the F1 key to start the batch and each output is activated and deactivated aut
42. pears to indicate file download oY Downloading application firmware 50249 0021B HE 7 75 File Size 159 459 11 132 152 453 Close after successful data transfer 9 After the download is complete cycle power on the indicator E1070 e tools Software User s Manual 45 Appendix A Print Format Commands Printing commands chart Dec HEX Token Application Group Parameter 128 GWT n Gross Weight 1 Weight OPTIONAL ASCII e U 2 9 1 Indicator Default 6 Range 2 9 Indicator Default 6 132 84 UN Units Weigt 135 87 ID Scale Serial Number Misc 136 88 TIM x Time Time MANDATORY DECIMAL Range 0 2 Editor Default 1 O Format as set active in indicator 1 hh mm 2 hh mm AM PM 137 DAT X Date Date MANDATORY DECIMAL Range 0 4 Editor Default 1 O Format as set active in indicator 1 MM DD YY 2 MM DD YYYY 3 DD MM YY 4 DD MM YYYY 138 8A TTV n Target Value Trip MANDATORY HEX s Range 31 33 Editor Default 1 For target weights Low Accept value 1 Range 2 9 Indicator Default 6 High Accept value 1 Range 2 9 Indicator Default 6 Ingredient x Actual value Range 2317 3871 Editor Default 1 For target weights in recipe 145 91 RTV n Active Recipe Recipe MANDATORY HEX s Ingredient x Target value Ran
43. pendix C EX E M r3 for full list wm LL 33 EndanFema Click here for a JW Eig Ecc z Click here to ee gop ie 3 S re Hage vane Data Types Delete Variable Tatal Butes D word order Data Type Type of Bytes Range of Value 27 to 127 This shows the total 0 to 255 number of bytes used by uA of 32767 to 32767 the indicator This 0 to 65535 information is required U A Signed Char S S igned Long 2 147 483 647 to 2 147 483 647 s ipe ae has nsigned Long 0 to 4 294 967 295 y calculated FLOAT Foa 4 TOES totoe 40 E1070 e tools Software User s Manual EtherNet 4 IT Server Click on EtherNet 4 IT Server in the drop down list to configure an EtherNet 4 IT Server network The window looks like this Net Manage Fieldbus 1 Settings Map natal SMTP Fieldbus Type D fieldbus IP Address KEE Select Indicator IP Address Key in the IP address for the indicator If you enable DHCP Dynamic Host Configuration Protocol the IP address for the indicator is not required Select Ethernet Addresses Key in the IP address for the host IP SMTP Gateway Subnet and key in the port number that the indicator and the remote host will be connected on Set Socket Mode SMA the SMA protocol over the Ethernet connection This is the exact same protocol used on the serial ports See the Service Serial section of the E1070 Service Manual for details Polled If Polled is cho
44. re User s Manual Filter tab Click the Filter tab and the following is displayed Configuration Scale Averages 20 Filter Enable Single Pole d m Filter Settings Constant 0 Threshold Weight X 0 Three pole filtering is faster response to weight in a short Averages time Single pole passive filtering is slower response to weight in a longer time period with im proved accuracy Filter settings Filter enable Set the number of A to D counts to be averaged for display or printed weight Choose values between 0 and 100 from the drop down list Choose disable to disable filtering or choose single pole or three pole filtering See note at left If you enable filtering Filter Settings appears For the Constant value you can pick a value between 1 and 10 Set the number low for small vibration problems and higher for more dampening effect The Threshold Weight parameter causes the indicator to respond quickly to large weight swings Threshold is the amount of weight swings in calibration units beyond which the filtering will be temporarily disabled For example if you set this to 10 Ibs a weight swing greater than 10 pounds occurring during the sample time will disable the filtering until the weight swings during the sample time is less than 10 Ibs E1070 e tools Software User s Manual 17 18 Ranges tab Click the Range tab and the following is displayed Configuration Scale Deadload
45. sen you will be prompted to select a polling charac ter Choices from O to 255 When the polling character is received on the Ethernet connection the indicator will act as if the PRINT key has been pressed all of the formats to print will be sent out of the configured port If you want the print format s to be sent back on the Ethernet connection the print formats must be configured for tcpip1 net1 or tcpip2 net2 Click the SMTP tab and the following is displayed Key in the User Name Net Manage Fieldbus 1 for the indicator ares o ee TIET User Name Key in the Domain Name o for the indicator C Key i n t h e en al l addr ess Sender Address this indicator s e mail address for the indicator Recipient Address Key in the email recipient s address jC Key in the subject of the email E1070 e tools Software User s Manual 41 Saving the File Downloading a File Indicator must be unsealed for a file to be downloaded to it See the Service Manual for details 42 When you have finished configuring all the items you can save the file by clicking on the File Save button on the Tool Bar This dialog box is displayed ME Select Configuration File 5 ave qn c3 T Emp T dm p 4 Mu Recent Documents Desktop Mu Documents Ta gr Mu Computer T My Network File name Places Save az type Configuration EIS Cancel ES Type in a file name and click Sav
46. to 63 after the download Click the Map Data tab and the following is displayed This shows the spacing of each Net Manage Fieldbus 1 piece of data as it Choose to create the will show up on Inbound Data Map or the PLC D Outbound Data Map bg by selecting your E choice here t nbound C Outbound Click here for a drop down list of Choose Endian Format network tokens Big or Little here See Appendix C for full list Endian Format Click here for a Big Endian z Click here to drop down list of OM trade swap the Data Types Delete Variable Total Bytes 0 word order Data Type Type Data f ofBytes Range of Value This shows the total S8 O0 SignedChar 3 127to127 number of bytes used by the indicator This iaoe atoa by the PLC programmer and is automatically calculated FLOAT 6 Float 4 1OEVtoi10E E1070 e tools Software User s Manual 35 ControlNet requires indicator option Valid nodes for ControlNet are 0 to 63 Node zero is reserved for hardware addressing I e switch settings done on the PC card for this fieldbus interface If an address greater than 63 is used the indicator will set the node to 63 after the download This shows the spacing of each piece of data as it will show up on Click on ControlNet in the drop down list to configure a ControlNet network The window looks like this Net Manage Fieldbus 1 Settings M
47. utput activates for the number of pulse counts set in the recipe and then deactivates Choose an Output Set the output you want associated with the ingredi ent Choices are 1 2 3 or None Choose a Delay Set a time delay between when a basis is met and the next ingredient action is started E1070 e tools Software User s Manual 21 22 Checkweigher tab Click the Checkweigher tab and select Enable Checkweigher Application The following choices will appear Configuration Applications Accumulator Batching Checkweigher Counting Peak Hold Remote Display General Weighing Print Format s Mode o Limits C Sample Setpoints Display Graduation Standard C Target Divisions Choose Print Format s Type in the print formats 0 10 that are to be printed when the PRINT button is pressed during normal operation Multiple print formats must be typed in ascending order For example Enter 0123410 and print formats O 1 2 3 4 and 10 are sent out the serial port Enable or disable the checkweigher graph on the indicator display Choose Limits or Sample mode Limits Mode User enters the upper and lower limits for the item and the indicator will use those values to run the display See illustration below Each graduation equals one division by default but this can be changed in the Display Graduation box Lower limit e limit lin aiii dL AU Each graduation 1 division default Sa