Home
Installation, Operation & Maintenance (IOM) Manual
Contents
1. Flush plug 1 16 x 27 NPT J UU Inlet 2 NPT L 4 06 10 32 All dimensions are in inches centimeters 1 4 pipe plug Appendix D Parts Details For the ZV200 Bypass Valve No Part No Description Qty 1 7001 050NC175A Hex head bolt 8 5363 1 25 Flange 1 25 NPT 2 5363 1 5 Flange 1 5 on 2 5363 2 Flange 2 NP 2 2 5363 2 5 Flange 2 5 NES 2 5363 1 25S Flange 1 25 slip weld 1 5363 1 5S Flange 1 5 slip weld 1 5363 28 Flange 2 slip weld 2 5363 2 58 Flange 2 5 slip weld 2 2 234 O ring 2 5506 Bypass valve body 1 5 5509 Relief valve 2 1 5511 Valve spring 91 125 psi 1 6 5512 Valve spring 126 150 psi 1 5513 Valve spring 41 70 psi 1 5515 Valve spring 71 90 psi 1 7 5457 Adjustment nut cap 1 8 7101 037NCO1A Hex nut 1 9 2732 Gasket 1 10 2911 Adjusting screw 1 11 5507 Bypass valve cap 2 1 12 2 235 O ring 1 13 2 223 _ O ring 1 14 5516 Spring guide 2 1 15 1629 Flush plug 1 16 x 27 NPT 2 16 5510 Nameplate 1 17 7012 006SF019E Pan hd Phillip 6 32 x 3 16 2 18 3442 Pipe plug 1 4 NPT 4 denotes O ring code See chart below O ring Code Buna N No Neoprene q Viton S PTFE Ethylene Propylene S K Kalrez 2 Q M O W
2. sssssesseeseeseeeen eene nnne nennen A a eA A aen j ennnnnnr n enhn nnne nnne nnne nnns 11 Applicable Notices for ATEX 94 9 EC Conformity Product Type Corken Liquid Transfer Bypass Valves Model covered ZV200 Intended Application The bypass valve models covered by this manual conform to the European Union ATEX 94 9 EC Directive for explosive gas atmospheres and transfer of liquefied gases such as Liquefied Petroleum Gas anhydrous ammonia freons etc Possible Misuse Warning The designated bypass valve models must only be installed in systems designed for its intended use similar to the examples presented in this manual ATEX Classification Group Il Category 2 G Temperature Class T4 T5 These products are classified under the ATEX directive as Equipment Group Il Category 2 equipment is intended for use in areas where explosive atmospheres caused by gases or vapors G may be present The surface Temperature Class rating is a range between T4 275 F 135 C and T5 212 F 100 C Nameplate BL y E N 6 ZV200 BYPASS om UT 2 oq CORK it Of IDEX mine SSEMBLED S A MONS 400 IN I MAX UAL BEFORE OPERATING Il 2GT4 TS d File number ATEX and machinery directive Exi Explosion protection Surface temperature range T4 135 C 275 F T5 100 C 212 F Explosion gas atmosp
3. AN Notice CORKEN BYPASS VALVES SHOULD ONLY BE INSTALLED IN LPG amp NH3 SYSTEMS THAT HAVE BEEN DESIGNED BY QUALIFIED ENGINEERING PERSONNEL AND OPERATED AND MAINTAINED BY QUALIFIED TECHNICIANS THE SYSTEM MUST CONFORM TO ALL APPLICABLE LOCAL AND NATIONAL REGULATIONS AND SAFETY STANDARDS SPECIFICALLY LPG SYSTEMS MUST CONFORM TO NFPA 58 THISMANUALMUSTBEKEPTWITHTHEBYPASS VALVES AND BE REVIEWED BEFORE INSTALLING OPERATING OR PERFORMING ANY MAINTENANCE WORK A Warning DO NOT ATTEMPT TO OPEN THE PUMP OR BYPASS VALVE UNTIL YOU HAVE BLED OFF THE PRESSURE HIGH PRESSURE IN THE SYSTEM CAN CAUSE PERSONAL INJURY AND OR PROPERTY DAMAGE PLEASE NOTE IF THE SYSTEM CONTAINS A METER THE DIFFERENTIAL VALVE WILL KEEP LIQUID UNDER PRESSURE IN THE PUMP METER AND PIPING EVEN AFTER THE HOSE HAS BEEN EMPTIED Installation A bypass valve is essential in an LPG application to maximize performance and extend life of the pump The valve should be installed to prevent excessive pressure resulting from accidental pump over speed discharge shut off or highly restrictive receiving systems The bypass valve must be installed downstream of the pump and piped back to the supply tank NOTE Never pipe a bypass valve back to the pump inlet This applies to below ground tank pumping system design as well The correct position for installation of the bypass valve is on the discharge side of the pump with the valve inlet and discharge indicated by the flow
4. gt Registered trademarks of the DuPont company Appendix E Troubleshooting Guide for the ZV200 Bypass Valve Issue Cause Solution Low capacity Valve set too low Note After all potential causes from the pump and system have been investigated Adjust valve as demonstrated in this IOM manual on pages 5 and 6 Adjusting screw will not turn Screw adjusted full in Adjustment too high back out adjustment and adjust valve per instructions in this IOM manual on pages 5 and 6 Noise from valve during System operation Spring broken Depressurize system Open valve and inspect Replace spring if necessary Adjustment screw set too far out Adjust valve per instructions in this IOM manual on pages 5 and 6 Excessive restriction in return line Remove restrictions Valve leaking product O ring failure Depressurize system Open valve and inspect Replace O ring Fitting loose Identify and tighten fitting Valve will not adjust to desired pressure Spring guide or O ring failure Depressurize system Open valve and inspect O ring and spring guide Appendix F Storage of the ZV200 Bypass Valve If your bypass valve is to be removed from service for some time it must be protected as propane butane and anhydrous ammonia all leave the metal bare and open to corrosion Piping and tanks not in service should also be protected as
5. bar optional 126 150 psi 9 0 10 3 bar optional Fitted with Buna N O rings Material Specifications Bypass valve body Part Material Adjustment nut cap ASTM A536 65 45 12 Adjusting screw Steel Ductile iron ASTM 536 60 40 18 Bypass valve cap Ductile iron ASTM 536 60 40 18 Gasket 1010 hot rolled steel Ductile iron ASTM 536 65 45 12 standard Flanges Plate steel ASTM A516 optional weld Buna N standard O rings Viton Neoprene EPDM PTFE Kalrez optional Spring Music wire chrome silicon Spring guide 8620 A322 ASTM steel Relief valve 17 4 PH stainless steel 2Viton Neoprene and Kalrez are registered trademarks of the DuPont Company Performance Differential Pressure Maximum Rated Flow for Propane psi bar gpm L min 70 4 82 180 681 120 8 27 250 946 Appendix C Outline Dimensions for the ZV200 Bypass Valve 2 38 1 04 6 00 2 63 SOM OOF j ON fas on oun 5 16 13 09 Discharge 2 NPT CUTE Bec VE eee O Qr EC
6. direction arrow on the side of the valve The ZV200 valve can be installed in a vertical or horizontal position in the piping The bypass valve and its piping should be sized to accommodate the full flow from the pump when the pump s discharge line is closed and the pump is running at its operated speed Piping line sizes should be at least as large as the valve openings If this is not performed properly it is possible that the actual operating conditions of the installation can be higher than the bypass valve setting and cause the valve to open thereby reducing system delivery and efficiency The outlet piping from the valve should return to the storage tank either into the liquid or vapor section Operation The standard ZV200 bypass valves are not preset at the factory The maximum pressure setting of the valve is 125 psi 8 62 bar for LP Gas and NH service per Underwriters Laboratories For optional spring ranges and settings refer to the bypass valve assembly drawing in this manual for a complete list of parts and construction configurations Cold Temperature Operation Note Impact strength is reduced at temperatures below 20 F 28 9 C Use extreme caution to prevent tools and other objects from impacting the pressurized components of the pumping system NOTE The bypass valve pressure setting must be verified when installed in a system Adjustment of the valve is as follows The differential pressure setting of t
7. the rust particles can destroy the pump s seals almost immediately after startup 1 Fill or thoroughly flush the bypass valve with a light rust inhibiting oil If the bypass valve is flushed with oil placing some desiccant packets inside the bypass valve will provide added protection Store in a dry location a Boo M Plug all bypass valve openings 11 Before placing the bypass valve back into service drain the oil and remove any desiccant packets Refer to the Operation of Your Bypass Valve on page 5 of this Installation Operation and Maintenance IOM manual Solutions beyond products CORKEN IEX Corken Inc A Unit of IDEX Corporation 3805 N W 36th St Oklahoma City OK 73112 Phone 405 946 5576 Fax 405 948 7343 Visit our website at http www corken com or e mail us at info corken idexcorp com Printed in the U S A September 2010
8. 805 N W 36 Street Oklahoma City Oklahoma 73112 Parts subject to wear or abuse such as mechanical seals vanes piston rings packing and other parts showing signs of abuse are not covered by this limited warranty Also equipment parts and accessories not manufactured by Corken but furnished with Corken products are not covered by this limited warranty and purchaser must look to the original manufacturer s warranty if any This limited warranty is void if the Corken product has been altered or repaired without the consent of Corken All implied warranties including any implied warranty of merchantability or fitness for a particular purpose are expressly negated to the extent permitted by law and shall in no event extend beyond the expressed warranty period Corken disclaims any liability for consequential damages due to breach of any written or implied warranty on Corken products Transfer of toxic dangerous flammable or explosive substances using Corken products is at the user s risk Such substances should be handled by experienced trained personnel in compliance with governmental and industrial safety standards Contacting The Factory Before you contact the factory note the model number and serial number of your pump The serial number directs us to a file containing all information on material specifications and test data applying to your specific pump When ordering parts the Corken service manual or Installation Operation and Ma
9. IH106B Installation Operation amp Maintenance Manual ZV200 Bypass Valve Model ZV200 Bypass Valve Warning 1 Periodic inspection and maintenance of Liquid Controls Group products is essential 2 Inspection maintenance and installation of Liquid Controls Group products must be made only by experienced trained and qualified personnel 3 Maintenance use and installation of Liquid Controls Group products must comply with Liquid Controls Group instructions applicable laws and safety standards such as NFPA Pamphlet 58 for LP Gas and ANSI K61 1 1972 for Anhydrous Ammonia 4 Transfer of toxic dangerous flammable or explosive substances using Liquid Controls Group products is at user s risk and equipment should be operated only by qualified personnel according to applicable laws and safety standards Solutions beyond products CORKEN Warning Install use and maintain this equipment according to Corken s instructions and all applicable federal state local laws and codes Periodic inspection and maintenance is essential Corken One Year Limited Warranty Corken Inc warrants that its products will be free from defects in material and workmanship for a period of 12 months following date of purchase from Corken Corken products which fail within the warranty period due to defects in material or workmanship will be repaired or replaced at Corken s option when returned freight prepaid to Corken Inc 3
10. charge line and bypass line shut off valves should be in full open position 5 Start the pump and circulate back to tank through the discharge line system 6 Slowly close the pump discharge line shut off valve and allow all capacity to flow through the bypass valve 7 Slowly increase the ZV200 bypass valve setting by turning the adjustment screw clockwise until the ammeter indicates the full load current indicated on the motor nameplate or required differential pressure is reached Record the pressure on the gauge mounted on the valve WARNING Do not adjust the valve beyond the range of the spring being used Note On Anhydrous Ammonia and LP Gas installations a maximum differential pressure of 125 psi is allowed by Underwriter s Laboratories Inc UL Standard for Safety for Power Operated Pumps for Anhydrous Ammonia and LP Gas UL 51 and NFPA Pamphlet 58 Liquefied Petroleum Gas Code Corken model 1521 pumps should never be operated over 100 psi differential Appendix A Model Number and Identification Code for Model ZV200 Model Number Identification Full opening high capacity bypass valve for full pump capacity Base Model Number ZV200 Inlet 2 NPT Outlet 2 NPT Maximum flow rate gpm 250 Ship weight Ib 23 Specification Fields 41 70 psig differential range No charge option A Springs 71 90 psig differential range No char
11. ge option C 91 125 psig differential range Standard B 126 150 psig differential range No charge option D Buna N Standard A Neoprene No charge option B O ring material Viton Charge option D PTFE Charge option E EPDM Charge option G Kalrez Charge option K 1 25 NPT No charge option A 1 50 NPT No charge option C 2 0 NPT Standard E Inlet Flanges 2 5 NPT No charge option J 1 25 Slip on weld Charge option B 1 50 Slip on weld Charge option D 2 0 Slip on weld Charge option F 2 5 Slip on weld Charge option K 1 25 NPT No charge option A 1 50 NPT No charge option C 2 0 NPT Standard E Outlet Flanges 2 5 NPT No charge option J 1 25 Slip on weld Charge option B 1 50 Slip on weld Charge option D 2 0 Slip on weld Charge option F 2 5 Slip on weld Charge option K Neoprene Viton and Kalrez are registered trademarks of the DuPont Company Accessory Options Description Part Number Optional hydrostatic relief valve 450 psig 2141 450 Hydrostatic test 3000 X5 Model Number Base XXXX Appendix B Technical Specifications and Performance Curves for the ZV200 Bypass Valve Operating Specifications Maximum differential pressure 150 psid 10 34 bar Operating temperature range Up to 225 F 107 C 1 Maximum working pressure Spring ranges 400 psi 27 6 bar 91 125 psi 6 3 8 6 bar standard 41 70 psi 2 8 4 8 bar optional 71 90 psi 4 9 6 2
12. he ZV200 valve is adjustable in various ranges depending on the size of the spring A tag is attached to the valve cap to identify the spring furnished and that information is repeated in the table below All of the springs for each valve size are interchangeable ZV200 Spring Differential Flange Sizes Number Pressure psig 5513 41 70 5515 71 90 1 1 4 1 1 2 2 2 1 2 5511 std 91 125 5512 126 150 Mobile Truck Mount Applications 1 Install liquid filled pressure gauges equipped with a needle valve or snubber in the following locations At the pump discharge gauge port on the tank on the inlet side of the ZV200 2 Connect the delivery hose to a receiving tank or to a delivery tank port for recirculation 3 All shut off valves in the pump s discharge line and the bypass return line should be open 4 Start pumping at normal delivery rate The delivery tank outlet valve should be wide open Record the pump discharge gauge pressure The difference between this reading and the tank pressure before pumping is the normal system operating pressure or differential pressure 5 To check the pressure setting of the pump s internal relief valve when applicable slowly close the shut off valve in the bypass return line Next slowly close the shut off valve in the pump s discharge line while observing the pump discharge gauge pressure Record the highest differential difference between discharge andta
13. here High level ATEX Directive 94 9 EC marking Equipment classified as Group Il Catagory 2 Training Instructions Instructions for the safe application and use of this product are provided in this manual Read this manual completely prior to installation and use of this product Only qualified and properly trained personnel should be allowed to install operate and maintain this equipment Mechanical Ignition Sources The bypass valve is installed as part of an assembly including the pump and the entire system must be grounded to prevent possible electrostatic discharge Preventive maintenance guidelines are provided in this manual and are to be followed for the proper operation and performance of the valve Sound Levels Theseproductsarereactionary devices usedin pumpingsystems Sound levels are highly dependent upon the application product being pumped and installation When operating in the system the valves should have a noise level no higher than 80 dBA Piping Forces and Moments Maximum Allowable Nozzle Forces and Moments Note Piping systems should be designed according to standard engineering practice and applicable national and local codes NO piping induced forces or moments are recommended for Corken ZV200 bypass valves X Horizontal perpendicular to valve discharge port Y Vertical Z Horizontal parallel to valve discharge port Fx Fy Fz 42 Ib 19 kg Mx My Mz 70 ftelb 10 kgem
14. intenance IOM manual should be consulted for the proper part numbers ALWAYS INCLUDE THE MODEL NUMBER AND SERIAL NUMBER WHEN ORDERING PARTS The model and serial numbers are shown on the nameplate of the unit Record this information for future reference Model No Serial No Date Purchased Date Installed Purchased From Installed By Table of Contents Applicable Notice for ATEX Conformity 00 0 0 cccccceceeeeeeeeeeeeeeeeee eee centr eee eae aaa emennhnn sss n hn nnns nnn tnn nnnnrns sss s dnas n sss h nnn nnn sensns sse ens 4 Installation and Operation of Your Bypass VAIVC ccceceeeccecceee eee e cette aaaaaaaeeeeeeeeeeeee eae nnne nenne rrtnns nsn n nnn nn nnn nrnnnnnes nnne 5 Appendix A Model Number and Identification Code ccccccccceecee eee eeeeeeceeeeeee eee eee e eee e essen nene neneenhn sns h nnn n nn nnn hn nnntesss nsa n nnns n nnn nnn nnns 7 Appendix B Technical Specifications and Performance ccccceeeeeeeeeceeeaee eee ener eet eaae aaa aaaeeee esse eee esa eaaaaaaaaaeeeeeeeeeeeseseeceeaaeeeeeeeeeees 8 Appendix C Outline DIMENSIONS sa iiano idrara ke rrr cepere ea eee dae e even Lape deux ced ar daaa aaa aa raana aa aara aandaa 9 Appendix D Parts Detalls 4 5 m natu ete a i m HIE uc C Esa a cor nb ER a i Doa Date t HL ues LIRE Ma Lco cca edes 10 Appendix E Troubleshooting GUID E 11 Appendix F Storage of the ZV200 Bypass Valve
15. nk pressure when the internal relief valve begins to open The highest or peak pressure must be recorded Once the valve opens the pressure may drop during recirculation On Corken Z model truck pumps this valve is non adjustable in the field The pressure at which the valve opens or cracks for specific applicable model pumps is listed below Z2000 135 145 psig Z3200 140 150 psig Warning If pressure continues to increase above 155 psig without dropping discontinue and refer to pump operations manual or contact the factory Open the pump discharge and ZV200 shut off valves and return to normal pumping 6 To check the ZV200 bypass valve setting gradually close the shut off valve in the pump s discharge line and record the gauge pressure The difference between this reading and the tank pressure before pumping is the external bypass valve setting record this number 7 Reopen the shut off valve in the pump s discharge line and resume normal pumping operation 8 Adjust the ZV200 setting if necessary On installations where the pump has an internal relief valve the ZV200 valve should be set at least 20 to 25 psi 1 38 to 1 72 bar below the setting of the pump s internal relief valve setting This will eliminate the possibility of erratic hunting between the two valves in the system and potential noise and accelerated wear on pump components This pressure setting will ensure that all the liquid doe
16. s not recirculate through the relief valve and cause excessive wear and noise The ZV200 external bypass valve setting should also be at least 15 psi 1 03 bar higher than the normal system operating pressure Operating pressure nearing the bypass valve setting may mean liquid is being recirculated unnecessarily Adjustment to the ZV200 external bypass valve can be made by removing the valve cap and loosening the locknut WARNING Do not remove the valve cap on the bypass valve until you have bled off the pressure To increase the pressure setting turn the adjusting stud and nut assembly or adjusting screw inward or clockwise To reduce the pressure setting turn the adjusting stud and nut assembly or adjusting screw outward or counter clockwise Stationary Pumping Installations equipped with an electric motor drive 1 Install liquid filled pressure gauges equipped with a needle valve or snubber in the following locations At the pump discharge gauge port on the tank on the inlet side of the ZV200 2 Attach an ammeter to a motor lead of the electric motor 3 Remove the valve cap on the ZV200 and adjust the valve to its lowest pressure setting by turning the adjusting screw counter clockwise until spring tension is no longer present Note Do not remove the adjusting screw WARNING Do not remove the valve cap on the bypass valve until the pressure has been bled off the valve 4 Check all valves The pump dis