Home

Quick Start Guide – Kawasaki Jet Skis Hardware and

image

Contents

1. Thank you for purchasing Candoopro Please read the following information before using the system for the first time If you have any questions about the use of the system please contact us at Sales candoopro com or visit our Forum at http forums candoopro com uick Start Guide Kawasaki Jet Skis The Candoopro Kawasaki version software works with the following Jet Ski models 1999 2003 STX 1100 Ultra 130 DI fuel injected 2002 2012 STX 12F STX 15F 2007 2012 Ultra LX 250X 250LX 260X 260LX 300X 300LX Hardware and Cable Guide what s included The Candoopro system setup for Kawasaki Jet Ski includes the following parts The Vehicle Diagnostic System Box which connects between your PC and the Jet Ski The USB Cable which connects the Vehicle Diagnostic System Box to the PC The Main Diagnostic cable is used to connect the Candoopro diagnostic box to all 4 stroke models The 2010 Adapter is used to connect the Main Diagnostic cable to the new style connector on 2010 Ultra skis The Early Relay Bypass cable is used on 2003 2012 STX 12F 15F skis to keep the ECU awake during the diagnostic session The Late Immobilizer Bypass cable is used on 2007 Ultra models to keep the ECU awake during the diagnostic session The 2 stroke DI Main Diagnostic cable is used to connect the Candoopro diagnostic box to the 1999 2003 STX 1100 Ultra 130 DI models Getting Started Loading Software and Starting up the P
2. nnecting to a ski please read the service manual for the particular model of Jet Ski In general starting a diagnostic session involves two steps 1 Connecting the Candoopro system to the Jet Ski diagnostic connector 2 Waking up the engine ECU to enable the Candoopro system to talk to the ECU In addition the 4 stroke models need an additional bypass cable attached to keep the ECU powered up during the diagnostic session 2003 2012 STX 12F 15F 4 stroke Models Connecting the Diagnostic Cable to the Jet Ski Steps to connect 1 Locate the 4 pin Diagnostic Connector which is located in the engine compartment adjacent to the voltage regulator assembly The connector is black and has a cap on it with yellow sealed inserts connector shown with dust cap removed 2 Remove the dust cap and plug the Candoopro Kawasaki Main Diagnostic cable into this connector 3 Locate the Main Relay connector located near the battery It is a light gray 8 pin connector shown disconnected 4 Disconnect the Main Relay connector and connect the Early Relay Bypass cable inline between the two halves of the Main Relay connector Fasten the ring terminal of the Early Relay Bypass cable to the negative ground post of the battery 5 Ensure the emergency stop tether is attached to the stop switch and attach the ignition key to the switch and turn to the ON position You are now ready to start the Diagnostic session 2007 2012 Ultra 4 str
3. oke Models LX 250 L X 260 L X 300 L X Connecting the Diagnostic Cable to the Jet Ski Steps to connect 1 Locate the 4 pin Diagnostic Connector which located next to the battery in the front storage compartment The connector is black on the 2007 2009 models and white on 2010 2012 models 2 Remove the dust cap from the connector and attach the Main Diagnostic cable to the diagnostic connector NOTE On 2007 2009 models the Main cable connects directly to the connector on the ski On 2010 models you must first attach the 2010 Adapter cable to the Main cable then connect the 2010 Adapter cable to the diagnostic connector on the ski 3 To keep the ECU powered up for the diagnostic session you must attach the Immobilizer Bypass cable The connector for the immobilizer is located behind the ECU so you need to first remove the ECU cover panel in the front storage compartment 4 Once you move the ECU out of the way you now have access to the immobilizer connector It is a natural nylon colored 6 pin connector 5 Disconnect this connector and connect the Late Immobilizer Bypass cable in line 6 Once the Immobilizer Bypass cable is installed connect the two small white one pin connectors together on this cable W 7 Insert a Kawasaki key either FAST or SLO into the key switch to power up the ski ensure the emergency lanyard is attached to the stop switch and you are now ready to start the diagnostic ses
4. rogram First Time Internet Connection is REQUIRED e Install USB Drivers by entering the following into your web browser o http www candoopro com candooinstall driver usbdriver exe e Connect CANDoo Professional System to the PC with the provided USB Cable e Install CANDoo Professional Software by entering the following into your web browser o http www candoopro com candooinstall CanDooPro msi e Start CANDoo Professional by going to start menu and launching CANDoo Professional o When prompted to download the new update you must select YES Each Use Internet Connection is Optional e Connect CANDoo Professional System to the PC with the provided USB Cable e Start CANDoo Professional by going to start menu and launching CANDoo Professional e Ifyou have a multi brand version of software Sea Doo Yamaha Kawasaki select Kawasaki e Bottom left of the CANDoo Professional software shows the current status USB Connection Status Vehicle Connection Status x P oo Looking for Vehicle Progress Bar Number of Connections O e Connect the Candoopro system to the Jet Ski Diagnostic Connector e For all 4 stroke models attach the appropriate bypass cable to keep the ECU powered up e Ensure the safety lanyard tether is attached to the stop switch e For the DI and 12F 15F models turn the key switch to ON e For the Ultra models insert a FAST or SLO key into the ignition switch Vehicle Connection NOTE Before co
5. sion 1999 to 2003 STX 1100 DI 2 stroke model Connecting the Diagnostic Cable to the Jet Ski Steps to connect 1 Remove the seat and look for the Yellow 6 pin diagnostic connector at the rear of the engine bay just under the seat It will have a dust cap on it with a looped single wire on the end of it 2 Remove the dust cap from the diagnostic connector and attach the STX 1100 DI Main Diagnostic cable to the yellow diagnostic connector on the ski 3 Ensure the Safety Lanyard is installed on the stop switch and turn the key to the ON position You are now ready to start the diagnostic session Starting the Diagnostic Session When the Candoopro application is running and the ECU has been powered up you are ready to start the diagnostic session Once the ECU is powered up the Candoopro application should detect the Kawasaki ECU indicated by the ski icon on the lower left of the screen changing from red to green and the status should change from Looking for Vehicle to Early Kawasaki for the STX 12F 15F Late Kawasaki for the Ultra series skis or Kawasaki DI Detected for the STX 1100 DI skis 1 Late Kawasaki Once the Kawasaki ECU detected indication appears go to the upper left of the screen select Vehicle then Read Vehicle 4 CANDoo Hardware Serial Number 344 Key Report Help Read Vehicle Write Vehicle The Candoopro system will read
6. the data from the ECU You are now ready to read and clear faults view operating history and activate various functions available for that particular model General Faq s e CANDoo Professional checks for updates on startup if there is an active internet connection e The hardware box must always be connected to the PC when you startup the program to enable the system to check for new updates e Ifyou are using wireless and get out of range it can cause CANDoo Professional to freeze up while trying to connect to the website on startup We suggest disabling the wireless on your laptop if you are moving out of wireless range e Make sure you have a fully charged battery failure to do so can cause data corruption e When you are done always close the program first before disconnecting the USB cable to the Candoopro box If you disconnect the USB cable before closing the program the program will freeze and you may need to stop the program manually via the Task Manager to exit the program

Download Pdf Manuals

image

Related Search

Related Contents

Zebra ZXP Series 1 User`s Manual (en)  lettre de réaction au projet de « Guide des  DZーHS1  Calibration Manual    Nilfisk-ALTO ATTIX 19 Gallon User's Manual  Samsung YP-E3Q User Manual  Installation, Operation & Service Manual  PDF: Ladegerät LiPo Balancer Charg (Download)  60cm Dishwasher  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.